Jaipur Vidyut Vitran Nigam Limited Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 18,000Document Cost
₹ 236Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_JVVNL_455404_17Bid Award Id
ViewTender No
NIT-14/2024-25 (KOTA)Tender Authority
Jaipur Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter/Direct- Ammeter/CT oertated ammeter/Frequency meter/KWH meter/Multi Function Meter/ Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Three phase Voltmeter with Inbuilt Selector Switch. (E/8.3.4)
1
1689
1689
... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter/Direct- Ammeter/CT oertated ammeter/Frequency meter/KWH meter/Multi Function Meter/ Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Three phase Ammeter with Inbuilt Selector Switch. (E/8.3.3)
1
1689
1689
... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection, with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required. All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR .Ring type tape wound CT, CT Class 1, Ratio upto 150/5, Burden 5 VA. (E/8.4.1.1)
1
614
614
... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. Body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Red/ yellow/Green colour (E/8.8.1)
1
170
170
... More
Providing & Laying P.V.C./XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I/IS :7098 P-I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity 99.7 %, round/flat strip armouring, Inner/outer sheath confirming to IS:5831 in existing RCC/Hume/Stoneware/PVC pipe/Open duct/Cable trench/Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product/work refer Annexure 'A' attached with this BSR.
-
-
-
... More
(A) 35 Sq mm 3 Core (E/11.4.8.3)
78
1651
128778
... More
(B) 16 Sq.mm 4 core (E/11.4.6.4)
76
1021
77596
... More
Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole. (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second. To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987, IEEE 80-2013 (clause 14.5d), IEEE 837 & IER 1956 with latest amendemnts. (c) Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt. (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR , 25 mm thick and 3 Mtr. Long. (E/14.4.2)
1
7955
7955
... More
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. 30mm x 5 mm copper strip. (E/14.5.4)
4
1940
7760
... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product/work refer Annexure 'A' attached with this BSR Four pole MCB (With B/C curve tripping Characteristics) 6A to 32A rating. (E/6.1.4.2)
3
1223
3669
... More
SITC of 3/4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings, conforming to IS/IEC 60947 P -2:2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR, shunt trip, earth fault trip, door interlock, pad lock & rotary handle, including making connections etc. as required. OEM shall have submit NABL/CPRI/ ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product/work refer Annexure 'A' attached with this BSR 4 pole MCCB With Thermal Magnetic release : (A) Up to 100 Amp, 25 kA, adjustable O/L & adjustable S/C setting, (E/9.3.3.2)
1
7112
7112
... More
(B) 160 Amp, 25 kA, adjustable O/L & adjustable S/C setting, (E/9.3.3.4)
1
11835
11835
... More
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 lm/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety. Power Factor0.95, THD(I) 10%, driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/ Embossing/Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/report with liable warranty of product/ accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. High Power LED Flood Light Minimum lumen output 22400 lm. (E/18.11.8)
9
13300
119700
... More
E/W in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in which or 10 sum on plan) inculading dressing of sides and ramming of bottoms, lift up to 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. (B/1.8)
30
178
5340
... More
P&L in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering -All work up to plinth level. (A) 1:4:8 ( 1 cement : 4 coarse sand: 8 graded stone aggregate 40mm nominal size.) (B/3.1.6)
2
3302
6604
... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786). Cold twisted deformed bars (IS : 1786). (B/4.13.1)
700
77
53900
... More
Centering & Shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundation, footing, strap beams, raft, bases of columns, etc. (B/4.9)
15
157
2355
... More
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix/Design Mix. (B/4.1)
6.1
4934
30097.4