If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 6,50,000 
Notes
Download

Costs

  • EMD

    ₹ 13,000
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 500

Summary

Work Of Release Of New Dedicated Separate 11 Kv Phed Mau Feeder From 33/11 Kv Gss Bamori Kalan Connected Load 136 Hp Contract Demand 154 Kva Lip Ht Connection In Favour Of Executive Engineer Phed Division Baran At Village Mau Under Aenonm Jpd Mangrol

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(A) Height of poles/R.S.Joist/M.S.Rail Size of Pit

-

-

-

... More
9 Mtr/1.2mx0.6mx1.5 m deep

143

36567

255.72

... More
(B) Lattice Tower

-

-

-

... More
11.4/10.8 Mtr/1.5mx1.5mx1.80m deep

16

20968

1310.5

... More
© Stay Set/Depth of pit

-

-

-

... More
6'x5/8"-0.75x0.5x1.35 m

108

22594

209.21

... More
Safe carriage of PCC poles including loading/un-loading.

-

-

-

... More
c) 9 Mtr. Long 200 Kg. PCC pole

-

-

-

... More
Within 10 Kms.

143

27807

194.46

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof.

143

13585

95

... More
Safe carriage of steel (fabricated and un-fabricated) i.e M.S.Rails, R.S .Joists, M.S. Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I.Stay Wire, G.I.Wire Nuts & Bolts etc.and ACSR Conductor including loading/unloading and stacking in Nigam stores/at work site.

-

-

-

... More
Within 10 Kms.

5.6

1823

325.65

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof.

5.6

516

92.2

... More
Insulator, hardware, cable, breakers, kiosk, pannels etc including loading unloading and stacking in Nigam store etc.

-

-

-

... More
Within 10 Kms.

2.2

858

390.29

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof.

2.2

245

111.4

... More
Safe carriage of fabricated lattice tower structures and sub- station structure type AB, Ab beams, Isolators structures etc. including loading /unloading and stacking at work site.

-

-

-

... More
With in 10 Kms

8

3797

474.71

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof.

8

737

92.2

... More
Safe Carriage of of 11/0.4 KV 3 phase distribution tranformer including loading/un-loading from store to site

-

-

-

... More
d) Above 100 KVA & up to 315 KVA

-

-

-

... More
Within 10 Kms.

1

889

889.63

... More
Above 10 Kms. & up to 30 Kms. Add for each Km. or part thereof.

1

230

230.4

... More
Safe carriage of breakers/kiosks etc. including loading /unloading and stacking in Nigam stores

-

-

-

... More
Within 10 Kms.

1

889

889.63

... More
Above 10Kms & upto 30 Kms Add for each Km or part thereof

1

230

230.4

... More
Erection of all type steel supports in the excavaterd pit in aligment after checking the same with plumb line including fixing of cross arms and top hampers before erecting the supports should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No 5.7 the remaining portion of the pit will be back filled with soil. The nuts &bolts will be provided by the contractor as per Nigam' s specification for which payment will be made at the prevailing store issue rates . the cost muffing and grouting will be paid extra

-

-

-

... More
lattice tower

8

39108

4888.53

... More
Erection of PCC poles in excavated pit with fixing of brackets, cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom Stores issue rates.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
PCC Poles 9 Mtr.Long ( 200 Kg)

117

44334

378.93

... More
Erection of assembly of 2 pole structures of steel supports PCC poles in excavated pit in alignment after checking the same with plumb line. Including fixing of top bracing of M (1 piece) with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
PCC Poles 9 Mtr.Long ( 200 Kg)

13

14365

1105

... More
Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps Stay Insulator with stay wire at both ends with proper tension. Size of stay set/stay wire.

-

-

-

... More
6'x5/8" with 7/10 SWG stay wire

108

26061

241.31

... More
Providing and laying of cement concret in ratio 1:3:6 using 43 grade cement river sand and 1/2 mm to 20 graded blasted crusher brokenin pit/foundation according to the size /type of supports /stay set including compaction /curing for 21 days in steel plate shuttring /farmer base.

24

67773

2823.89

... More
Supply and laying of randum rubble stone boulder stone having weight not less than 20 kgs.

75.3

34846

462.77

... More
Fixing of all type of fabricated material on erected support with nuts and bolts as per approved design and drawing of sub-station.

1

3160

3160.02

... More
Fixing and assembly of disc point channel pair with pilot plates & clamps on erected double pole structure as per design. The nuts & bolts are to be provided by the contractor as per Nigam specification for which payment will be made as per prevailing Discom store issue rates

-

-

-

... More
11 KV line

-

-

-

... More
Fixing and assembly of disc point channel pair with pilot plates top hampers & clamps on erected single pole structure as per design. The nuts & bolts are to be provided by the contractor as per Nigam specification for which payment will be made as per prevailing Discom store issue rates

-

-

-

... More
11 KV line

18

1068

59.37

... More
Fixing of 11 KV B&S & T&C type disc insulator for 11 KV lines (each unit consisting of 1 nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips.

165

3681

22.31

... More
Fixing of 11 KV pin Insulator with pin.

396

3928

9.92

... More
Assembly, Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories complete in all respect with post insulator and jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(A) G.O.Switch with earthign blade

-

-

-

... More
11 KV G.O.switch

2

1927

963.97

... More
Assembly and installation of Horn Gape fuse set (set of 3 nos.) on erected structure as per design, complete in all respect with post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
11 KV Horn Gap fuse set

2

889

444.96

... More
Installation of lightening arrestors on erected structure /support (set of 3 Nos ) Including connection with earth by wire b/stop as required and jumpering etc .The nuts &bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(A) sub station type

-

-

-

... More
33 KV L.A. set

3

512

170.95

... More
Installation testing as per Nigam's norms & commissioning of 11/0.4 KV distribution transformer on erected supports including fixing of base channels as per requirement jump ring of HV&LV side,crimping of lugs/clamping earth connection of body and new-trial of transformer with wire /strip( as already provided with earthing) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rate.

-

-

-

... More
Above 100 KVA and up to 315 KVA

1

941

941.34

... More
Fixing of PG clamps of weasel /Rabbit conductor

72

357

4.97

... More
Laying, jointing, stringing, tensioning and clamping of conductor with proper sage as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding on pin insulators, jumpering on section points with binding wire/ P.G. clamps. Aluminum jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
ACSR RABBIT

24.6

54267

2205.98

... More
ACSRDOG

0.1

258

2584.3

... More
Laying, jointing, stringing, tensioning and clamping of G.I.Earth wire continuously on single/double pole by using earth clamps/nuts & bolts with washers and earth reel etc. including proper binding at each end. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom, store issue rates.

-

-

-

... More
(B) IN RURAL AREA

-

-

-

... More
G.I.Earth wire 8 SWG

8.2

6039

736.47

... More
Drawing & stringing of G.I. 4 wire over the guarding bracket for guarding of road crossing/P&T crossing, Railway track crossing (for one span only) with cross G.I.wire laces at an interval of one meter each or required as per location using EYE bolt, nuts and bolts with washers etc. including binding. The EYE bolts and other nuts and bolts will be provided by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(a) 4 Wire stringing

-

-

-

... More
8 SWG with laces of 10 SWG

136

93835

689.97

... More
Earthing of line for all type of support as per REC construction standards using stay wire / GI wire with one pcs MS rod 20 mm dia each 3 meter long and driving into earth by mechinical means as per approved design. Drawing & specification. alll material expect MS Rod, MS Flat & Stay wire will be supplied by the contracotr, the payment will be made as per priviling Discom issue rate. ( In case of PCC poles earthing must be connected with earth wire already available on PCC pole at bottom).

20

6704

335.22

... More
Earthing of 11/0.4 KV distribution transformer / substation with 3 PCS of MS rod 20 mm dia each 3 meter long and driving them into earth by mechanical means as per approved design. drawing & specification. the work includes flatting of top ends MS rod, drilling ahole of 9/16" dia. at flattened top and tighteing of M.S. flat 50x6mm(having 3 holes 2ends and 1 mm middle )with nuts and bolts with M.S. rod the end will be connected to equipments as under in sequence..

3

673

224.62

... More
Mesh earthing for 33/11 KV sub station as per apporved map & design using MS flat 50x6mm/MS rad 20 mm dia including laying of flat/rod at the depth of 0.65 mtrs welding & jointing at joint ,structures & equpments etc as under.

-

-

-

... More
Excavation of trench of 0.65 mtrs depth and 0.5 mtrs width.

-

-

-

... More
Normal soil.

30

3635

121.19

... More
Shaping of MS flat for connecting the equipment with earth mesh. The work including the welding of MS flat with eq- uipments/structures and also with earth mesh . The work also including cotting of MS flat joint with molten biutmen imprag- ated tape to protect from rust.

30

1162

38.74

... More
Preparation of spikes made of MS rod of 20mm dia and 3mtrs length as per design and requirement to be driven in earth by machnical means and provid-ing & fastining of suatable clamp with the MS ros connection of earth wire stay wire/MS flat in clamp depanding on type of soil.

-

-

-

... More
Where drilling is not required

45

8563

190.31

... More
Erection of OCB/Kiosk/ VCB Complete with accessories including use of special tool and conducting all pre- commissioning test before energization filling oil etc complete in all respect with erection and grouting of structure (executing civil work ). The relays will be tested by Discom.

-

-

-

... More
11 KV OCB/ KIOSK

1

4062

4062.97

... More
Installation of current potential transformer on supporting structure including checking of wiring &conducting all pre commissioning tests before energization &satisfactory operation in all respect(The CT/PT set will be tested by Discom)

-

-

-

... More
11 KV CT (1 set of 3 Nos.) or PT set

2

2473

1236.88

... More
Installation of metering point on 11 KV outgoing feeder at 33/11 KV S/S

2

39550

19775.39

... More
The installation work to be carried out as per drawing/ design under the supervision of concerned assistant engineer

-

-

-

... More
Mounting structure

-

-

-

... More
The requisite steel member will be supplied by contractor including the hardware, contractor shall joint/ weld the ,members to form the mounting structure as per drawing necessary tools, welding , machines, lifting device etc shall be arranged by contractor.

-

-

-

... More
Civil work

-

-

-

... More
Erection of lattice in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size ( crusher broken)) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing the period as required (21 days). Area of concreting will be as per the drawing.

-

-

-

... More
Metering equipment

-

-

-

... More
The requisite metering equipments (CTPT set, meter , meter box & suitable conductor for jumper), will be provided by the concerned Assistant Engineer in healthy condition at site. The cable from CTPT set to meter box laid down in 50 mm GI Pipe with suitable bends & nipples, shall be provided by contractor along with the consumable items such as PVC tapes, petroleum jelly etc. The cable should be PVC multi strand copper 4 core 2.5/4 sq mm ISI marked and firm & tight connections shall be made by suitable lugs etc. The CTPT sets so installed shall be earthed by means of the MS flat( size 50x6 mm) by joining it with the nearest earthling available at the sub station. requisite earthing material SHALL BE MADE AVAILABLE BY THE CONTRACTOR.

-

-

-

... More
Meter

-

-

-

... More
Meter should be fixed firmly inside the tamper proof box, as per drawing. All the meter fixture will be provided by the contractor including all consumables.

-

-

-

... More
Meter Box

-

-

-

... More
The meter box shall be provided by the concerned assistant engineer. However, hardware or any other items required to fix the meter inside the meter box will be provided by contractor. The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block ( TTB) link type shall be provided by contractor in the meter box.

-

-

-

... More
Painting

-

-

-

... More
All surface interior and exterior of lattice structure shall be white aluminum painted.

-

-

-

... More
Commissioning of Metering Equipments:

-

-

-

... More
Installed meters inside the box and metering equipments duly mounted on the mounting structure will be provided up by connecting load in the presence on the concerned Assistant Engineer who will arrange the necessary shut down. The completion certificate shall be furnished by contractor be filled accordingly. Since the work involves higher AC voltage level, the contractor shall take full care regarding safety norms, so as to avoid any accidental hazards.

-

-

-

... More
Laying of 11 KV XLPE cable (Almunium conductor ) underground as per relevant IS /JVVNL standerd including excavation of 30 cm x 120 cm deep trench in Kacha land 25 cm thick under layer of sand 'A' class beicks covering refilling soil in the remaining (including fixing of G.I. Pipe of reuired size at both end with 3 meter projeted above the ground surface & 0.3 meter below ground level).

-

-

-

... More
a) 3x35 sq mm to 3x 185 sq mm

120

11469

95.58

... More
Note -per meter shall be paid extra for excavation in Pukka Road .

120

12904

107.54

... More
Installation of cable terminal /straight through joints on 11 KV Almunium conductor XLPE /PILCA cable with outdoor / indoor termination joint including required.

-

-

-

... More
A) (I) outdoor end terminal 3 x 35 sq mm to 3 x 185 sq mm

2

2065

1032.94

... More
B) (I) indoor and terminal 3 x 35 sq mm to 3 x 185 sq mm

2

1893

946.89

... More
Safe carriage of CT/PT set (all size ) including loading and unloading from Nigam store to site.

-

-

-

... More
(a) within 10 km

2

350

175.22

... More
(b) Above 10 km upto 30 km Add for each km or part there off.

2

200

100.2

... More
supply of nuts & bolts

175

14428

82.45



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.