If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,86,000Document Cost
₹ 1,770Tender Fee
₹ 1,500
Summary
Const. Of Two Side B.wall, Earth Filling, Borewell And Other Misc. Civil Works Under Sub Division And Development Works For Model Sub Station At 33 Kv S/s Diggi.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_JVVNL_436507_23Bid Award Id
ViewTender No
E-NIT 11/2024-25Tender Authority
Jaipur Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT, terms and condition, special condition, declaration format etc.
BOQ Items
... More
(A) M-15 Grade N.Mix. 1:2:4 ( 1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size.) (B/3.1.2)
9
4624
41616
... More
RR dry stone kharanja under floor. (B-11.26)
45
932
41940
... More
RR stone masonry for with hard stone in foundation and plinth in CSM above 30cm thick wall in CM 1:6 (1cement :6 Sand). (B/6.1.6)
232
2838
658416
... More
P & L in position specifed grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1: 3 (1cement : 3 coarse sand) and making good the joints & cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix /Design Mix. (B-4.1)
11
4934
54274
... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. .(B-4.10.2)
95
340
32300
... More
Brick work with F.P.S. brick of class designation 75 in s/s above plinth level upto floor V level in all shapes & sizes in : CM 1:6 (1cement :6 coarse sand). (B-5.2.2)
64
4990
319360
... More
P & F reinforcement for R.C.C. work including straightening, cutting, banding, placing in position and binding (including cost of binding wire) all complete up to floor five level. Hot rolled deformed bars (IS:1139). (B-4.13.2)
1240
77
95480
... More
P & F precast cement concrete coping 1:2:4 mix 50 mm thick copmlete as per specification : (B-3.8)
71
367
26057
... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 75 mm thick with 20mm thick nominal size aggregate. (B-11.3.2)
10
458
4580
... More
Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finished. (A) 20mm thick. (B-12.3.2)
715
190
135850
... More
(B) 12 mm thick. (B-12.3.3)
351
160
56160
... More
Finishing walls with acrylic smooth exterior paint of required shade including all scaffolding. New work (two or more coats applied @ 1.67 ltr/10sqm over & including base coat of water proofing cement paint applied @ 2.20 Kg/10sqm). (B-12.42)
1950
86
167700
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work (B-12.46.1)
182
69
12558
... More
(B)One or more coats on old work. (B-12.46.2)
150
34
5100
... More
Add extra forsquare or Rectangular Pillars in S/S brick work upto five storey. (A) Upto 45 cm length and two corners are free (B-5.3.2)
14.5
163
2363.5
... More
Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. (A) Nominal bore 200 mm dia.(P-2.4.2)
55
1038
57090
... More
(B) Nominal bore 150 mm dia.(P-2.4.1)
145
692
100340
... More
Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.(P-2.4.3)
100
103
10380
... More
Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.32 mm dia. (P-2.24.1)
150
446
66900
... More
Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.(P-2.10)
2
1392
2784
... More
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. (P-2.22)
2
690
1380
... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.200 mm dia.(P-2.23.3)
1
978
978
... More
P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6.0 Sq.mm 3 core flat / Round (E-4.7.4)
210
300
63000
... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) (P-2.11.2)
56
3211
179816
... More
Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 200 mm dia nominal bore of 5.4mm thickness.(P-2.12.3)
12
295
3540
... More
SITC of Contactor OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . For single phase Submersible / Monoblock pump 2.0 HP to 3.0 HP (DOL starter) (E-21.13.1.2)
1
5406
5406
... More
SITC of Radial / mixed flow ISI marked water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034 : 2018 and IS: 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 with required accessories including making connection suitable for Bore well. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer. Annexure "A" attached with this BSR. 100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. 3.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound (E 21.6.1.4)
1
42469
42469
... More
Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design). (B-9.7)
2940
74
217560
... More
Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. (B-17.1)
75
689
51675
... More
Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished seamless type tubes. (B-9.3.2)
800
109
87200
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: (B-9.2)
750
81
60750
... More
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.Extra if square,rectangular hollow tubelar sections are used or grill made by flats only. (B-9.8+9.8.1)
2005
105
211728
... More
Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc. Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used.Add extra over rates of item No. 11.38, A to C if colored paver blocks are used(B-11.38.3.(A)+11.39)
1560
1197
1868724
... More
Add extra over rates of item No. 11.38, A to C if colored paver blocks are used(B-11.40)
750
217
163350
... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement :3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer in- charge). (B-11.29)
9
6103
54927
... More
Providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra)(B-9.37)
200
266
53200
... More
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand) (B-5.1.2)
6
4263
25578
... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi. (only for colour changing ).(B-12.35.7)
1455
4
5820
... More
Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete (B-13.23)
30
332
9960
... More
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete, New Plastered Surface (three or more coats) (B-12.22.1)
920
84
77280
... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer.(B-12.37.1)
580
75
43500
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements