Jaipur Vidyut Vitran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jan 2025
Closing Date16 Jan 2025
Tender Amount₹ 47,63,503 
Notes
Download

Costs

  • EMD

    ₹ 95,270
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 590

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(1.2) Lattice Tower /Size of pit

-

-

-

... More
(i) 11.4/10.8Mtr/1 .5mx1 .5m x1.80 m deep

15

335

5035.35

... More
(ii) 12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep

6

354

2129.4

... More
(1.3) Stay set/Depth of pit

-

-

-

... More
(i) 8'x 3/4" -0.75x0.5x1.6 m

12

79

959.64

... More
(2) Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken ) in foundation plinth excluding the cost of shuttering using 1 cement: 5 Sand :10 aggregate mix.

58

2371

137529.02

... More
(3) Plaster on new surface on walls in cement ,sand mortar 1:6 including racking of joint etc. complete fine finsh 25mm thick.

125

128

16040

... More
(4) Cement concrete flooring grade 1 :2:4 ( 1-cement :2-coarse sand :4-graded stone aggregate ) rounding off edges etc.but excluding cost of nosing of steps etc.complete.

-

-

-

... More
(4.1) 25 mm thick with 12.5 mm thick nominal size aggregate.

30

167

5021.7

... More
(4.2) 75 mm thick with 20 mm thick nominal size aggregate

9

398

3590.28

... More
(5) Masonry for foundation and plinth

-

-

-

... More
(5.1) Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.

20

1924

38496.6

... More
(6) Safe carriage of steel( fabricated and unfabricated} l.e.M.S. Rails, RS.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.l.Stay Sets, G.I. Stay Wire, G.l.Wire Nut & Bolts etc. and ACSR Conductorincluding loading and unloading and stacking in Nigam store /at work site

-

-

-

... More
(6.1) Within 10 Kms

3.5

325

1139.77

... More
(6.2) Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.

3.5

92

322.7

... More
(7) Safe Carriage ·of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam stores etc.

-

-

-

... More
(7.1) Within 10 Kms.

170

390

66349.3

... More
(7.2) Above 10 Kms. & upto 30 Kms. Add for each Km.orpart thereof.

170

111

18938

... More
(8) Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams,isolators structures etc. including loading/unloading and stacking in the Nigam Stores /at work site.

-

-

-

... More
(8.1) Within 10Kms.

5

474

2373.55

... More
(8.2) Above 10 Kms. & upto 30 Kms. Add for each Km.orpart thereof.

5

92

461

... More
(9) Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site

-

-

-

... More
(9.1) 25 & 40 KVA

-

-

-

... More
(i) Within 10 Kms.

1

238

238.51

... More
(ii) Above 10 Kms. & upto 30 Kms Add for each Km.or part thereof.

1

135

135.6

... More
(10) Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores

-

-

-

... More
(10.1) Within 10 KMs.

11

889

9785.93

... More
(10.2) Above 10 Kms. and upto 30 Kms.Add per each km,or part thereof

11

230

2534.4

... More
(11) Safe Carriage of 33/11 KV Power Transformer

-

-

-

... More
(11.1) 8.0 MVA

-

-

-

... More
(i) Within 10 Kms

1

6400

6400.29

... More
(ii) Above 10 Kms & upto 30 Kms . Add for each Km or part thereof

1

1279

1279.8

... More
(12) Safe loading of steel fabricated / unfabricated conductor drum & other line material.

1

220

220.54

... More
(13) Safe unloading of steel fabricated/ unfabricated conductor drum & other line material.

1

108

108.71

... More
(14) Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire

-

-

-

... More
(14.1) 8"x3/4" with 7/8 SWG stay wire

12

278

3345.72

... More
(15) Erection & fixing of steel struts in the excavated pit in position.The top end of the strut will be properly holed/welded with the main support muffed in cement concrete of ratio 1:3:6 as per item No.5.7.The nuts and bolts will be provided by the contractor as per Nigams specification for which payment will be made at the prevailing store issue rate.The cost of muffing and grouting will be paid extra.

-

-

-

... More
(15.1) R.S.Joists

1

1722

1722.75

... More
(15.2) Lattice Structure

5.3

3410

18073.11

... More
(16) Fixing and assembly of disc.point channel pair with pilot plates top hampers & clamps on erected single pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(16.1) 33 KV line

13

81

1059.76

... More
(16.2) 11 KV line

8

59

474.96

... More
(17) Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware andstrips.

54

46

2535.84

... More
(18) Fixing of 33kv pin insulator with pins.

18

14

267.66

... More
(19) Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates

-

-

-

... More
(19.1) GO. switch . without earthing blade

-

-

-

... More
(i) 33 kv G.O.switch

6

1112

6673.74

... More
(ii) 11kv G.O.switch

8

865

6920.8

... More
(20) Installation of lightening arrestors on erected structure /support (set of 3 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(20.1) sub-station type

-

-

-

... More
(i) 33 KV L.A. set

1

170

170.95

... More
(21) Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(21.1) 25 and 40 KVA

1

621

621.01

... More
(22) Erection of LT Distribution piller Boxes of 800/400/160/100 Amps. Capacity.Each 37"x24" base as per JVVNL standard including excavation,bricks,sand,cement masonary of size 4"x3"x10"and 3' in ground and 1 1/2'above road level with muffing to support and mounting the piller .Themasonary will have 4" X 4" opening 2"below ground level two in the rear sideand one each in the remaining sides to facilitate entry and exist of incomingand outgoing PVC cable.Earthing of the piller shall be connected to DPearth with 7/10 SWG StayWire & lugs.

-

-

-

... More
(22.1) 100 AMP.

1

2212

2212.35

... More
(23) Fixing of PG clamp of Dog Conductor

55

4

273.35

... More
(24) Erection of 11 KV RMU complete with accessories on existing foundation including use of special tools & conducting all pre-commissioning test before energization, connecting the cable ect. Complete in all respect with erection & groutinh of structure (excluding civil works for which payment shall be made extra as per clause No 2.6 of CLRC). The relays will be tested by Discom.

1

4062

4062.97

... More
(25) Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire /P.G.clamps . Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
(25.1) IN URBAN AREA

-

-

-

... More
(i) ACSR DOG

0.55

2915

1603.27

... More
(26) Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discomstore issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)

11

335

3687.42

... More
(27) Mesh earthing for 33/11 kv sub-station as per approyed map &design using MS flat 50X6mm/MS road 20mm dia including laying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints structJres & equipments etc. as under:

-

-

-

... More
(27.1) Excavation of trench of 0.65 Mtrs. depth and 0.5 Mtr. width

-

-

-

... More
(i) Normal soil

80

121

9695.2

... More
(28) Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

200

25

5146

... More
(29) Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earthmesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

97

38

3757.78

... More
(30) Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be drlven in earth by mechanical means and Providing & fastening of suitable clampswith the M.S. rod , connection of earth wire/stay wire/MS flat in clamp depending on type of soil

-

-

-

... More
(30.1) Where drilling is not required

46

190

8754.26

... More
(30.2) Where drilling is required

50

623

31150.5

... More
(31) Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.

40

7

285.2

... More
(32) Pipe Earthing for Power Transformer as 33/11 KV S/S:- Supply & erection of earthing elecctrode shall consist of G.I. Pipe 100 mm of 3 Mtr. Length. The electrode shall be buried as far as practicalbe 3 meter below ground level. Wherever possible, earth electrodes shall be located a near the water tab, water drain or near down take pipe, Earth electrodes shall not be installed in proximlty to a metal fence. It shall be kept clear of the building foundations and in no case it shall be nearer than 2 meters from the outer face of the wall. The electrode shall be surrounded with layer of charooal dust and salt mixture through out the length. The 100 mm GI pipeshall be provided with holes of 12 mm dia driled at 75 mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a GI threaded cap for watering the earth thourgh a pipe. A Clamp with Pati of 12" of MS Flat of size50s6 mm shall be fixed (Bolted) on the top edge of the pipe which in turn shall be connected to Neutral/ Body of the Power Transformer through MS Flat size 50x6 mm. The GI cap over the GI pipe shall be housed in a masonry chamber, approxmately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC inspection cover resting over a RCC frame, embedded in masony.

2

5117

10234.24

... More
(33) Supply & Erection of Maintenance free Gel Earthing with pipe in pipe I pipe in strip technology filled with anti ctjrrosive conductive compound (CPRI Tested) below the ground in 150-200 mm dia. Earth pit & surrourding filled with

2

6767

13534.94

... More
(34) Laying/stringing of bus bar with ACSR Dog & jumper conntection using tie rod , 33KV /11 KV insulator strin s,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.

-

-

-

... More
(34.1) ACSR PANTHER

30

30

911.7

... More
(34.2) ACSR DOG/RABBIT

80

23

1877.6

... More
(35) Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
(35.1) 33 KV VCB/SF-6 Breaker

3

5013

15041.88

... More
(35.2) 11 KV VCB (Indoor )

8

4062

32503.76

... More
(36) Erection & commissioning of battery set and battery charger including all required connection/wiring from battery set to battery charger and A.C.mains complete in all respect.

-

-

-

... More
(36.1) 110 Volts D.C.

1

1236

1236.88

... More
(37) Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.

-

-

-

... More
(37.1) 2x2.5 Sq.mm.

150

13

2014.5

... More
(37.2) 12x2.5 Sq.mm.

70

24

1725.5

... More
(38) Laying, connecting, testing and commissioning of 1100 Volt PVC cable at 33/11 KV Sub-Station including connections of leads cutting stripping of cable insulation providing compression type terminals fixing of cable glands crimping of lugs clamping of cable cores etc. complete in all respect as per requirement of Engineer Incharge. PVC cable size.

-

-

-

... More
(38.1) 3.5 Core 50 Sq.mm.to 95 Sq.mm.

20

33

673.2

... More
(39) Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)

-

-

-

... More
(39.1) On new surface

200

32

6494

... More
(40) Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)

-

-

-

... More
(40.1) On new works with two coats.

200

48

9740

... More
(41) Fabrication of steel structures of M.S angle,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing

-

-

-

... More
(41.1) Other steel items

1

4427

4427.99

... More
(42) To Supply & Replace the damaged / defective parts of 33 KV G.O switch (proper shut down will be provided by Nigam), Rates are inclusive of material,

-

-

-

... More
(42.1) 33 KV G.O (800Amps)

-

-

-

... More
(i) PG Clamp (33KV ISOLATOR CLAMP FOR PANTHER COND.)

36

251

9063

... More
(43) Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE /PILCA Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required

-

-

-

... More
(43.1) Outdoor end terminal

-

-

-

... More
(i) 3x35 Sq mm to 3x185 Sq mm

20

1032

20658.8

... More
(ii) If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm O/D Joint) Rate - 1032.68 Rs

20

1135

22718.96

... More
(iii) 3x240 Sq mm to 3x400 Sq mm

2

1205

2410.16

... More
(iv) If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm O/D Joint) Rate - 1133.10 Rs

2

1246

2492.82

... More
(43.2) Indoor end terminal

-

-

-

... More
(i) 3x35 Sq mm to 3x185 Sq mm

4

946

3787.56

... More
(ii) If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm I/D Joint) Rate - 910.55 Rs

4

1001

4006.42

... More
(iii) 3x240 Sq mm to 3x400 Sq mm

4

1157

4628.64

... More
(iv) If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm I/D Joint) Rate - 1009.90 Rs

4

1110

4443.56

... More
(43.3) Straight through joint

-

-

-

... More
(i) 3x35 to 3x185 Sq mm

19

2151

40884.39

... More
(ii) If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm S/TJoint) Rate - 3108.89 Rs

19

3419

64975.8

... More
(44) Installation of 33 KV Cable (XLPE) termination / straight through joints ( Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required.(Including crimping of lugs)

-

-

-

... More
(44.1) Outdoor end terminal

-

-

-

... More
(i) 3x240 Sq mm to 3x400 Sq mm

12

1577

18935.88

... More
(ii) If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm O/D Joint) Rate - 3632.69 Rs

12

3995

47951.51

... More
(44.2) Indoor end termination

-

-

-

... More
(i) 3x240 Sq mm to 3x400 Sq mm

2

1262

2524.7

... More
(ii) If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm I/D Joint) Rate - 3526.48 Rs

2

3879

7758.26

... More
(44.3) Straight through joint

-

-

-

... More
(i) 3x240 Sq mm to 3x400 Sq mm

30

3366

100992

... More
(ii) If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm S/T Joint) Rate - 10787.76 Rs

30

11866

355996.08

... More
(45) Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine "VERMIER".(120 cm deep).Use of this technology must be restricted to the situation like:- (i) When the passages available for laying the proposed cable is totally a metal or cement concrete road. (ii) When the road cutting is not permitted by the local administration.

-

-

-

... More
(45.1) 33 / 11 KV 3C x 300 Sq.mm cable

7200

302

2176416

... More
(45.2) When cable laying through manual trench less (Bogie)

-

-

-

... More
(i) 33/11 KV below 3CX300 Sqmm.

5770

182

1053948.2

... More
(46) For Extra loop (Ghera) to be provided near the pole on termination point and the length of cable along the pole for mounting of cable jointing kit

-

-

-

... More
(46.1) 11 KV Cable:-

-

-

-

... More
(i) 3x35 Sq mm to 3x185 Sq mm

480

91

44001.6

... More
(ii) 3x240 Sq mm to 3x400 Sq mm

160

103

16502.4

... More
(46.2) 33 KV Cable:-

-

-

-

... More
(i) 3x240 Sq mm to 3x400 Sq mm

500

223

111730

... More
(47) Craine with driver and P.O.L

-

-

-

... More
(i) 18 T

35

967

33861.8

... More
(ii) 12 T

100

806

80622



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.