Jaipur Vidyut Vitran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jan 2025
Closing Date16 Jan 2025
Tender Amount₹ 39,95,222 
Notes
Download

Costs

  • EMD

    ₹ 79,904
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 590

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(i)(B) Lattice Tower /Size of pit

-

-

-

... More
(1.2)11.4/10.8Mtr/1 .5mx1 .5m x1.80 m deep

15

305

4577.4

... More
(2)Excavation of pit in Hard soil.(15% extra shell be payable for the designated desert area panchayat samities of Jodhpur Discom in pursuance to Jdvvnl order No. 1240 dt.18.07.13 )

-

-

-

... More
(i)(B) Lattice Tower /Size of pit

-

-

-

... More
(2.1)11.4/10.8Mtr/1 .5mx1 .5m x1.80 m deep

15

335

5035.35

... More
(3)Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken ) in foundation plinth excluding the cost of shuttering using 1 cement: 5 Sand :10 aggregate mix.

55

2371

130415.45

... More
(4)Plaster on new surface on walls in cement ,sand mortar 1:6 including racking of joint etc. complete fine finsh 25mm thick.

120

128

15398.4

... More
(5)Cement concrete flooring grade 1 :2:4 ( 1-cement :2-coarse sand :4-graded stone aggregate ) rounding off edges etc.but excluding cost of nosing of steps etc.complete.

-

-

-

... More
(5.1)25 mm thick with 12.5 mm thick nominal size aggregate.

35

167

5858.65

... More
(5.2)75 mm thick with 20 mm thick nominal size aggregate

15

398

5983.8

... More
(6)Masonry for foundation and plinth

-

-

-

... More
(6.1)Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.

20

1924

38496.6

... More
(7)Safe carriage of steel( fabricated and unfabricated} l.e.M.S. Rails, RS.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.l.Stay Sets, G.I. Stay Wire, G.l.Wire Nut & Bolts etc. and ACSR Conductorincluding loading and unloading and stacking in Nigam store /at work site

-

-

-

... More
(7.1)Within 10 Kms

3.5

325

1139.77

... More
(7.2)Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.

3.5

92

322.7

... More
(8)Safe Carriage ·of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam stores etc.

-

-

-

... More
(8.1)Within 10 Kms.

140

390

54640.6

... More
(8.2)Above 10 Kms. & upto 30 Kms. Add for each Km.orpart thereof.

140

111

15596

... More
(9)Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams,isolators structures etc. including loading/unloading and stacking in the Nigam Stores /at work site.

-

-

-

... More
(9.1)Within 10Kms.

5

474

2373.55

... More
(9.2)Above 10 Kms. & upto 30 Kms. Add for each Km.orpart thereof.

5

92

461

... More
(10)Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site

-

-

-

... More
(i)b) 25 & 40 KVA

-

-

-

... More
(10.1)Within 10 Kms.

1

238

238.51

... More
(10.2)Above 10 Kms. & upto 30 Kms Add for each Km.or part thereof.

1

135

135.6

... More
(11)Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores

-

-

-

... More
(11.1)Within 10 KMs.

11

889

9785.93

... More
(11.2)Above 10 Kms. and upto 30 Kms.Add per each km,or part thereof

11

230

2534.4

... More
(12)Safe Carriage of 33/11 KV Power Transformer

-

-

-

... More
(12.1)8.0 MVA

-

-

-

... More
(12.2)Within 10 Kms

1

6400

6400.29

... More
(12.3)Above 10 Kms & upto 30 Kms . Add for each Km or part thereof

1

1279

1279.8

... More
(13)Safe loading of steel fabricated / unfabricated conductor drum & other line material.

2

220

441.08

... More
(13.1)Safe unloading of steel fabricated/ unfabricated conductor drum & other line material.

2

108

217.42

... More
(14)Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire

-

-

-

... More
(14.1)8"x3/4" with 7/8 SWG stay wire

-

-

-

... More
(15)Erection & fixing of steel struts in the excavated pit in position.The top end of the strut will be properly holed/welded with the main support muffed in cement concrete of ratio 1:3:6 as per item No.5.7.The nuts and bolts will be provided by the contractor as per Nigams specification for which payment will be made at the prevailing store issue rate.The cost of muffing and grouting will be paid extra.

-

-

-

... More
(15.1)R.S.Joists

1

1722

1722.75

... More
(15.2)Lattice Structure

6

3410

20460.12

... More
(16)Fixing and assembly of disc.point channel pair with pilot plates top hampers & clamps on erected single pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(16.1)33 KV line

5

81

407.6

... More
(16.2)11 KV line

9

59

534.33

... More
(17)Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware andstrips.

144

46

6762.24

... More
(18)Fixing of shackle insulator with hardware.

-

-

-

... More
(19)Fixing of 33kv pin insulator with pins.

-

-

-

... More
(20)Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates

-

-

-

... More
(i)(B)GO. switch . without earthing blade

-

-

-

... More
(20.1)33 kv G.O.switch

14

1112

15572.06

... More
(20.2)11kv G.O.switch

9

865

7785.9

... More
(21)Installation of lightening arrestors on erected structure /support (set of 3 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(i)(A)sub-station type

-

-

-

... More
(21.1)33 KV L.A. set

3

170

512.85

... More
(22)Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(22.1)25 and 40 KVA

1

621

621.01

... More
(23)Erection of LT Distribution piller Boxes of 800/400/160/100 Amps. Capacity.Each 37"x24" base as per JVVNL standard including excavation,bricks,sand,cement masonary of size 4"x3"x10"and 3' in ground and 1 1/2'above road level with muffing to support and mounting the piller .Themasonary will have 4" X 4" opening 2"below ground level two in the rear sideand one each in the remaining sides to facilitate entry and exist of incomingand outgoing PVC cable.Earthing of the piller shall be connected to DPearth with 7/10 SWG StayWire & lugs.

-

-

-

... More
(23.1)100 AMP.

1

2212

2212.35

... More
(24)Laying of 1100 V, LT 3.5/4 core PVC/XLPE cable, of aluminiumconductor and fixing with cable clamps making conections/jumpers by alluminium lugs/ PG clamps of required size onLV side of distribution transformer/ LT distribution mains onone end and with MCB with /with isolater unit/ pillar box on theother end. Lugs should be crimped with crimping tool.Lugs/P.G.clamps will by provided by the contractor ,for which payment will be made as per prevalling Discom store issue rates.(outgoing feeder cable will also be considered as circuit)

-

-

-

... More
(i)d) 70 Sq.mm

1

222

222.4

... More
(25)(C) Fixing of PG clamp of Panther Conductor

100

7

791

... More
(26)Erection of 11 KV RMU complete with accessories on existing foundation including use of special tools & conducting all pre-commissioning test before energization, connecting the cable ect. Complete in all respect with erection & groutinh of structure (excluding civil works for which payment shall be made extra as per clause No 2.6 of CLRC). The relays will be tested by Discom.

1

4062

4062.97

... More
(27)Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discomstore issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)

15

335

5028.3

... More
(28)Mesh earthing for 33/11 kv sub-station as per approyed map &design using MS flat 50X6mm/MS road 20mm dia including laying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints structJres & equipments etc. as under:

-

-

-

... More
(28.1)Excavation of trench of 0.65 Mtrs. depth and 0.5 Mtr. width

-

-

-

... More
(i)Normal soil

90

121

10907.1

... More
(28.2)Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

300

25

7719

... More
(28.3)Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earthmesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

100

38

3874

... More
(28.4)Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be drlven in earth by mechanical means and Providing & fastening of suitable clampswith the M.S. rod , connection of earth wire/stay wire/MS flat in clamp depending on type of soil

-

-

-

... More
(i)Where drilling is not required

50

190

9515.5

... More
(ii)Where drilling is required

26

623

16198.26

... More
(28.5)Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.

70

7

499.1

... More
(29)Pipe Earthing for Power Transformer as 33/11 KV S/S:- Supply & erection of earthing elecctrode shall consist of G.I. Pipe 100 mm of 3 Mtr. Length. The electrode shall be buried as far as practicalbe 3 meter below ground level. Wherever possible, earth electrodes shall be located a near the water tab, water drain or near down take pipe, Earth electrodes shall not be installed in proximlty to a metal fence. It shall be kept clear of the building foundations and in no case it shall be nearer than 2 meters from the outer face of the wall. The electrode shall be surrounded with layer of charooal dust and salt mixture through out the length. The 100 mm GI pipeshall be provided with holes of 12 mm dia driled at 75 mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a GI threaded cap for watering the earth thourgh a pipe. A Clamp with Pati of 12" of MS Flat of size50s6 mm shall be fixed (Bolted) on the top edge of the pipe which in turn shall be connected to Neutral/ Body of the Power Transformer through MS Flat size 50x6 mm. The GI cap over the GI pipe shall be housed in a masonry chamber, approxmately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC inspection cover resting over a RCC frame, embedded in masony.

2

5117

10234.24

... More
(30)Supply & Erection of Maintenance free Gel Earthing with pipe in pipe I pipe in strip technology filled with anti ctjrrosive conductive compound (CPRI Tested) below the ground in 150-200 mm dia. Earth pit & surrourding filled with

2

6767

13534.94

... More
(31)Erection of steel supports in the excavated pit in alignment after checking then same with plumb line as per approved design and drawing of 33/11KV Sub- station.The support should be grouted and muffed in cement concrete ratio 1:3:6 as per chapter -5 code No.5.7.The remaining portion of the pit will be back filled with soil.The charges for grouting & muffing will be paid by extra as per chapter code no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Store issue rates.

-

-

-

... More
(31.1)R.S.Joists

1

1621

1621.53

... More
(31.2)Fabricated structure AB type

3

1868

5606.7

... More
(31.3)Fabricated structure AB-1 type

3

1868

5606.7

... More
(31.4)Isolator / C.T.structure

2

1868

3737.8

... More
(32)Laying/stringing of bus bar with ACSR Dog & jumper conntection using tie rod , 33KV /11 KV insulator strin s,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.

-

-

-

... More
(32.1)ACSR PANTHER

250

30

7597.5

... More
(32.2)ACSR DOG/RABBIT

70

23

1642.9

... More
(33)Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
(33.1)33 KV VCB/SF-6 Breaker

3

5013

15041.88

... More
(33.2)11 KV VCB (Indoor )

8

4062

32503.76

... More
(34)Erection & commissioning of battery set and battery charger including all required connection/wiring from battery set to battery charger and A.C.mains complete in all respect.

-

-

-

... More
(34.1)110 Volts D.C.

1

1236

1236.88

... More
(35)Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.

-

-

-

... More
(35.1)2x2.5 Sq.mm.

150

13

2014.5

... More
(35.2)12x2.5 Sq.mm.

30

24

739.5

... More
(36)Supply andFixing of metallic junction box size 450x300x250 mm outdoor type floor mounting fabricated out of cold rolled steel sheet 16 SWG with required branching and support of M.S. Angle 45x45x5mm The box should be printed with the coat of Zinc Chromate primer and 2 coats of light grey paint. Removal of gland plate of 3 mm. Thickness with rubber gasket for cable entry at bottom gland plate should be spacious to fix 6 Nos. cable glands of 25mm size double hinged door with pad lock provision should be gasket with foam & rubber to make junction box dust & water proof supply of junction box will include following items.

-

-

-

... More
(37)Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)

-

-

-

... More
(37.1)On new surface

200

32

6494

... More
(38)Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)

-

-

-

... More
(38.1)On new works with two coats.

200

48

9740

... More
(39)Fabrication of steel structures of M.S angle,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing

-

-

-

... More
(39.1)Other steel items

1

4427

4427.99

... More
(40)To Supply & Replace the damaged / defective parts of 33 KV G.O switch (proper shut down will be provided by Nigam), Rates are inclusive of material,

-

-

-

... More
(i)33 KV G.O (800Amps)

-

-

-

... More
(ii)PG Clamp (33KV ISOLATOR CLAMP )

84

251

21147

... More
(41)Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE /PILCA Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required

-

-

-

... More
(i)(I) Outdoor end terminal 3x35 Sq mm to 3x185 Sq mm

23

1032

23757.62

... More
(ii)If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm O/D Joint) Rate - 1032.68 Rs

23

1135

26126.8

... More
(iii)(ii) 3x240 Sq mm to 3x400 Sq mm

2

1205

2410.16

... More
(iv)If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm O/D Joint) Rate - 1133.10 Rs

2

1246

2492.82

... More
(v)(I) Indoor end terminal 3x35 Sq mm to 3x185 Sq mm

5

946

4734.45

... More
(vi)If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm I/D Joint) Rate - 910.55 Rs

5

1001

5008.03

... More
(vii)(ii) 3x240 Sq mm to 3x400 Sq mm

4

1157

4628.64

... More
(viii)If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm I/D Joint) Rate - 1009.90 Rs

4

1110

4443.56

... More
(ix)(I) Straight through joint 3x35 to 3x185 Sq mm

16

2151

34428.96

... More
(x)If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm S/TJoint) Rate - 3108.89 Rs

16

3419

54716.46

... More
(42)Installation of 33 KV Cable (XLPE) termination / straight through joints ( Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required.(Including crimping of lugs)

-

-

-

... More
(i)(I) Outdoor end terminal

-

-

-

... More
(ii)(ii) 3x240 Sq mm to 3x400 Sq mm

12

1577

18935.88

... More
(iii)If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm O/D Joint) Rate - 3632.69 Rs

12

3995

47951.51

... More
(iv) (I) Indoor end termination

-

-

-

... More
(v)(ii) 3x240 Sq mm to 3x400 Sq mm

-

-

-

... More
(vi)If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm I/D Joint) Rate - 3526.48 Rs

-

-

-

... More
(vii)(i) Straight through joint

-

-

-

... More
(viii)(ii) 3x240 Sq mm to 3x400 Sq mm

24

3366

80793.6

... More
(ix)If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm S/T Joint) Rate - 10787.76 Rs

24

11866

284796.86

... More
(43)Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine "VERMIER".(120 cm deep).Use of this technology must be restricted to the situation like:-

-

-

-

... More
(i)(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.

-

-

-

... More
(ii)(ii) When the road cutting is not permitted by the local administration.

-

-

-

... More
(iii)A) 33 / 11 KV 3C x 300 Sq.mm cable

5800

302

1753224

... More
(43.1)When cable laying through manual trench less (Bogie)

-

-

-

... More
(i)(ii)33/11 KV below 3CX300 Sqmm.

4400

182

803704

... More
(44)For Extra loop (Ghera) to be provided near the pole on termination point and the length of cable along the pole for mounting of cable jointing kit

-

-

-

... More
(i)11 KV Cable:-

-

-

-

... More
(ii)3x35 Sq mm to 3x185 Sq mm

440

91

40334.8

... More
(iii)3x240 Sq mm to 3x400 Sq mm

160

103

16502.4

... More
(iv)33 KV Cable:-

-

-

-

... More
(v)3x240 Sq mm to 3x400 Sq mm

500

223

111730

... More
(45) Craine with driver and P.O.L

-

-

-

... More
(i)18 T

35

967

33861.8

... More
(ii)12 T

100

806

80622



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.