Jaipur Vidyut Vitran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,10,000Document Cost
₹ 1,770Tender Fee
₹ 1,500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_JVVNL_406561_12Bid Award Id
ViewTender No
SE CIVIL JVVNL JAIPUR E-NIT No 04/2024-25Tender Authority
Jaipur Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
4.1
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
3
14802
4934
... More
4.9
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
9
1413
157
... More
4.13.2
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)
Hot rolled deformed bars (IS : 1139).
200
15400
77
... More
5.2.2
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
54
269460
4990
... More
(B-65/5.3.2)
Add extra for Square or Rectangular Pillars in Superstructre brick work up to five storey Upto 45 cm length and two corners are free
7
1141
163
... More
(B-162/14.55)
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
965
14475
15
... More
(B-139/12.3.2)
Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish:
20mm thick.
985
187150
190
... More
(B) 12mm thick (12.3.3)
710
113600
160
... More
(B-13.1)
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
300
70500
235
... More
11.38.3(A)
Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)
M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc.
Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004
865
941985
1089
... More
11.29
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge).
9
54927
6103
... More
(B-56/3.8)
Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification :
230
84410
367
... More
(B-103/9.36.1)
Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron rovided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size.
50mm x 50mm x 3.15mm
410
257890
629
... More
B-9.33+9.35+9.35.1
Add or deduct for each wire line over basic item Extra for using galvanized barbed wire instead of black barbed wire.
Add Extra if barbed wire fencing is done on wall upto height of 3.00 Mtr.
3095
40854
13.2
... More
9.8
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.
2030
194880
96
... More
9.8.1
(A) Extra if square,rectangular hollow tubelar sections are used or grill made by flats only
2030
19488
9.6
... More
(B-98/9.2)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
875
70875
81
... More
(B-12.37.3)
Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only)
980
3920
4
... More
(B-142/12.22.1)
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete.
(A) New Plastered Surface (three or more coats)
980
82320
84
... More
(B-144/12.37.1)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:
New work (two or more coats) over and including scrapping andpriming coat with cement primer.
620
46500
75
... More
(B-145/12.42)
Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ).
2900
249400
86
... More
(B-146/12.46.1)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
(A) Two or more coats on new work
135
9315
69
... More
(B-146/12.46.2)
One or more coats on old work.
200
6800
34
... More
(B-154/13.33)- ( C )(i) Repair of door, window shutters including cost of material and labour for change of damaged :
Aldrop of mild steel 12'' long x 12 mm dia
6
882
147
... More
(B-154/13.33)- (d)-(ii) stopper of aluminium with double rubber gurka
10
470
47
... More
(B-154/13.33)- (g) mild steel tower bolt 6" size
6
234
39
... More
(B-154/13.33)- (i) steel handle 6" size
8
192
24
... More
(B-152/13.24)
Labour charges for repair to door / window with out using any material such as applying randha ( finishing ) tightening of bolts & screw etc
16
3520
220
... More
(B-150/13.4.1)
Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm
13
8021
617
... More
(B-11.17.4)
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)
Ordinary cement without any pigment.
20
9460
473
... More
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement : 4 coarse sand). (A) For area of each slab from 2001 to 5000 sq. Cm: (11.18.2)
65
66495
1023
... More
Kota stone slabes 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (A) For area of each slab upto 2000 sq. Cm: (11.19.1)
10
9120
912
... More
(B-72/6.17.3)
Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :
Kota stone minimum 30mm thick.
3
1827
609
... More
P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge Size 500x400mm (1.45.1)
2
702
351
... More
1.36.4
P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :
Size 580 mm x 450 mm
2
5490
2745
... More
P & F Towel Rall or Ring of approved quality/make.C.P. brass Towel Rail with brackets 450x20mm. (1.47.3)
2
592
296
... More
1.52.1
P & F Soap Dish or Tray of approved quality/make C.P. brass
2
254
127
... More
2.12.1/S-2
P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. inlet connection 15mm Brass(Is: 8931 marked)
6
3006
501
... More
2.7.3 /S-2
P & F Bib cock (IS: 8931 Mark), Superior quality of approved make:
(A) C.P. brass bib cock 15mm nominal bore.
6
3540
590
... More
P & F Full - way Valve (IS: 778 Mark) or wheel valve of approved make:
(A) Gun metal 15 mm nominal bore. (2.15.1)
8
1816
227
... More
(B) Gun metal 25 mm nominal bore. (2.15.3)
8
4232
529
... More
P & F 15mm. Dia Connection pipe of approved quality/ make: (A) PVC Pipe with C.P. Brass nuts upto length 450mm. (2.13.3)
6
606
101
... More
2.26.3/S-2
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 ltr capacity
2
7840
3920
... More
2.11.1/S-2
P & F Ball Cock (IS: 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. Not less than 300 gm,15mm.
2
628
314
... More
P & F rigid PVC pipe ( IS: 4985 make) class II/(4 Kg./Cm2). Approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant.
(A) 110mm dia. (3.16.3)
55
15510
282
... More
P & F rigid pvc pipe fittings (IS : 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant :110 mm dia.(A) Bend 45˚ (3.17.8.ii)
6
768
128
... More
(B) Bend 87.5˚ .(3.17.9.ii)
10
1610
161
... More
(C) Vent Cowel (3.17.12.ii)
2
112
56
... More
(F) Pipe clip (3.17.15(ii))
20
720
36
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.
(External work).
(A) 20mm nominal size (2.39.2)
80
15680
196
... More
(B) 25 mm nominal size (2.39.3)
80
20960
262
... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box , 10 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
(A) Short point (up to 3 mtr.) (3.1.1)
10
3610
361
... More
(B) Medium point (up to 6 mtr.) (3.1.2)
10
5840
584
... More
© Long point (up to 10 mtr.) (3.1.3)
8
6512
814
... More
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC Trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box, modular 10A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
On board (3.3.1)
6
2334
389
... More
Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. . For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (7.36)
4
1212
303
... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
(A) 2 x 2.5 sq. mm. + 1x1.5sqmm (4.1.7)
60
4860
81
... More
(B) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (4.1.14)
50
6100
122
... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity 95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 8 SWG G.I. ( Hot Dipped ) Wire. (14.6.8)
6
120
20
... More
14.2
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
1
5733
5733
... More
Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD 20% ,p.f.≥0.95,CRI 80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing. (17.2.2)
8
2160
270
... More
(E-90/17.9.3)
Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI 70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR. 9 Watt
5
575
115
... More
Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(7.20)
5
995
199
... More
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
1200 mm Sweep BEE 3 Star rated (service value =5.0 to 5.5 ) (15.7.3)
3
6570
2190
... More
15.11.2
Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 300 mm sweep
1
1822
1822
... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Single pole MCB (With B/C curve tripping Characteristics). 6 A to 32 A rating. (6.1.1.2)
6
1122
187
... More
Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Four pole Isolator. 63 A rating. (6.2.3.2)
1
818
818
... More
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Metaldoor (single phase) IK-09 and IP-43 with Metal end box (E-22/6.10.1.3)
8 way(8+2)
1
2184
2184
... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(E-95/18.12.2)
LED Street Light fixture with Minimum lumen output 3700 lm
4
13480
3370
... More
(E-95/18.12.6)
LED Street Light fixture with Minimum lumen output 11225 lm
8
54120
6765
... More
(E-96/18.18.3)
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR : 32 mm Dia.
12
8904
742
... More
(E-56/11.2.1.1)
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4.0sqmm 2core.
160
17440
109
Evaluation Notes How It Works ?