Jaipur Vidyut Vitran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 33,000Document Cost
₹ 590Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_JVVNL_421072_1Tender No
E-NIT 15/2024-25Tender Authority
Jaipur Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT, terms and condition, special condition, declaration format etc
BOQ Items
2.19.1/PHED
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 3 core 4.0 Sq.mm
100
20000
200
3 core 10.0 Sq.mm (2.19.3/PHED)
400
204400
511
4.8.4/S-4
S & F tube well cover of M.S. sheet (6 mm th ) with nuts and bolts complete for casing size 200 mm dia
3
1119
373
2.22/PHED
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.
6
4140
690
21.6.2.1/E
SITC of Radial / mixed flow ISI marked water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034 : 2018 and IS: 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 with required accessories including making connection suitable for Bore well. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.
3.0 HP, 3-Ø, (54 -95)Mtr, (250-50) LPM
7
317800
45400
5.0 HP, 3-Ø, (68 - 102)Mtr, (225-85) LPM (21.6.2.2)
2
106048
53024
12.5 HP, 3-Ø, (78 - 126)Mtr, (395-245) LPM (21.6.2.5)
1
78975
78975
21.13.1.2/E
SITC of Contactor OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . For single phase Submersible / Monoblock pump 2.0 HP to 3.0 HP (DOL starter)
5
27030
5406
21.13.2.1/E
For Three phase Submersible / Mono block pump
Upto 3.0 HP ( DOL starter )
3
21738
7246
3.0 HP to 5.0 HP ( DOL starter ) (21.13.2.2)
2
20346
10173
12.5 HP to 15.0 HP ( Star / Delta starter ) (21.13.2.6)
2
43422
21711
21.3.1/E
Providing & Laying of Polypropylene rope Confirming to IS:5175 for submersible pump of following sizes. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 12mm ( suitable for upto 50mm OD pipe)
200
8600
43
2.25.1/PHED
Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect.40 mm dia
200
19200
96
26.74.2/E
Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 2.0 H.P.to 3.0 HP
30
188550
6285
Above 3.0 HP to 5.0 HP (26.74.3/E)
2
16582
8291
From7. 5 HP to 10.0 HP (26.74.4/E)
2
20592
10296
26.75.2/E
Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 2.0 H.P.to 3.0 HP
30
118350
3945
Above 3.0 HP to 5.0 HP (26.75.3/E)
2
10698
5349
From7. 5 HP to 10.0 HP (26.75.4/E)
2
13372
6686
21.2.2.1/E
Supply & fixing of PVC threaded casing pipes for Tube well (IS 12818:1992) of 3mtr. Each for depth up to 1200 ft. Plain and strainer Casing CS for Depth upto 400ft. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . more than 400 ft to 1200 ft. Depth
40mm dia
200
28000
140
Evaluation Notes How It Works ?