Jaipur Vidyut Vitran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Civil And Construction
Excavation
Eprocure
Opening Date12 Dec 2024
Closing Date16 Dec 2024
Tender Amount₹ 17,00,000 
Notes
Download

Costs

  • EMD

    ₹ 34,000
  • Document Cost

    ₹ 590
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
B 3.1.6 Providing & Laying in position cement concrete i/c curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering – All work up to plinth level.: (A) 1:4:8 (1 cement:4 course sand: 8 graded stone aggregate 40 mm nominal size).

34

3302

112268

... More
6.1.6/B-6 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:l in Cement sand Mortar 1:6 (1- Cement: 6- Sand).

32

2838

90816

... More
B 6.2.6 Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in :

12

3479

41748

... More
5.2.2/B-5 Brick masonry with F.P.S. bricks of class designation 75 in Super structure above plinth level upto floor 5th level in all shapes and sizes in cement mortar 1:6 (1- cement: 6- coarse sand).

2

4990

9980

... More
5.8.3/B-5 Half brick masonry in super structure, above plinth level upto 5th level using bricks of designation 75 in Cement mortar 1: 6 (1- Cement: 6- Coarse sand).

6

526

3156

... More
Add extra for Random Rubble stone masonry with hard stone in(A) Wall upto 30cm. and less thickness. (B 6.3.4)

58

186

10788

... More
(B)Square or Rectangular pillars (B 6.3.1)

8.9

173

1539.7

... More
3.8/B-3 P/F precast cement concrete coping 1:2:4 mix 50 mm thick complete as per specifications 50mm

53

367

19451

... More
Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) : Raised and cut pointing.(B 12.31.2)

45

233

10485

... More
8.13.2.1/B-8 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure ‘A’ 30mm thick. Commercial veneer both side.

22

1841

40502

... More
B 8.14 Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13.

22

141

3102

... More
12.3.2/B-12 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: (A) 20mm thick

109

190

20710

... More
9.26/B-9 Supplying and fixing fixed wire gauge of 14 mesh X 24 gauge to the metal frame of rolled section by metal beading 20X3 mm with suitable screw at not exceeding 150 mm distance.

29

617

17893

... More
B 13.4.1. Renewing glass panes,with putty and nails wherever necessaryFloat glass panes of thickness 4 mm

29

617

17893

... More
12.5/B-12 6mm thick cement plaster to celling of mix 1:3 (1 cement : 3 fine sand)

248

139

34472

... More
B 10.17.1 Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

16

4483

71728

... More
11.3.2 /B-11 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. (A) 75mm thick with 20mm thick nominal size aggregate.

91

458

41678

... More
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.(B 14.55)

310

15

4650

... More
B 13.29 Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 2 in following steps i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried. ii) Applying Epoxy primer on the exposed steel bars. iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush. iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day. v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete. vi) Cure the plastered surface for 15 days All work including scaffolding etc. complete in all respect.

30

1568

47040

... More
B 13.1 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : With cement mortar 1 :4 ( 1 cement : 4 coarse sand)

40

235

9400

... More
9.8.1/B-9 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide

110

96

10560

... More
9.8.2/B-9 Extra if square,rectangular hollow tubular sections are used or grill made by flats only

110

9

1056

... More
B 12.45.1 Applying priming coat : With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood.

30

29

870

... More
B 12.46.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: (A) Two or more coats on new work.

135

69

9315

... More
R/6.7 (iii) (a) P & l of Interlocking M-30 grade concrete Block pavements having thickness 80 mm as per drawings & MoRD Specification Clause 1504 with M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blocks. Category 'A' Dentated units to key into each other on all four faces zigzag shape as per IRC: SP:63-2004.

294

907

266658

... More
12.37.1 /B-12 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: (A) old work (two or more coats) over and i/c scrapping and priming coat with cement primer.Colur Same

838

11

9218

... More
B 12.43.2 Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision old work

281

50

14050

... More
B 13.12 Repair to stone masonary in cement sand mortar 1:6 with old and new stone.

10

318

3180

... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . (A) LED Street Light fixture with Minimum lumen output 11225 lm. (E 18.12.6)

6

6765

40590

... More
(B) LED Street Light fixture with Minimum lumen output 2450 lm. (E 18.12.1)

6

2554

15324

... More
1.14.3/S-1 P & F Ist quality WVC urinal (IS : 2556 mark) with 25 mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc: complete Mini stall size 455x385x350mm.

1

2287

2287

... More
1.20.2/S-3 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS : 7231 .

2

1291

2582

... More
1.36.3/S-1 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :size 550x400 mm

2

2598

5196

... More
2.13.2/S-2 P & F 15mm Dia Connection Pipe of approved quality/make PVC pipe with C.P. brass nuts upto length, 370mm

4

79

316

... More
2.7.3 /S-2 P & F Bib cock (IS: 8931 Mark), Superior quality of approved make: (A) C.P. brass bib cock 15mm nominal bore.

4

590

2360

... More
2.11.2/S-2 P & F Ball Cock (IS: 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. not less than 400gm 20mm

2

372

744

... More
2.12.1/S-2 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. inlet connection 15mm Brass(Is: 8931 marked)

4

501

2004

... More
2.15.1 /S-2 P & F Full - way Valve (IS: 778 Mark) or wheel valve of approved make: (A) Gun metal 15 mm nominal bore

3

227

681

... More
(B) Gun metal 25 mm nominal bore (S 2.15.3)

3

529

1587

... More
2.26.3/S-2 P & F PVC Storage Tank ( IS: 12701 marked indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 CM long wash out pipe with plug & socket, including making connection etc., complete of approvrd design: 500 ltr capacity

2

3920

7840

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) (A) 20mm nominal size (S 2.37.2)

200

222

44400

... More
(B) 25mm nominal outer dia pipes (S 2.37.3)

150

282

42300

... More
2.39.2/S Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work). (A) 20mm nominal outer dia pipes

60

196

11760

... More
(B) 25mm nominal outer dia pipes (S 2.39.3)

60

262

15720

... More
3.3.1/S Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe) 100mm dia S.W. pipe

10

217

2170

... More
S 3.22.3 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth.

1

16100

16100

... More
3.19.1/s-3 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M

1

5489

5489

... More
P & F Grating of approved quality/ make Stainless steel sheet size 125 mm dia. (S 1.48.1)

4

62

248

... More
3.16.2 /S-3 P & F rigid PVC pipe ( IS: 4985 make) class II/(4 Kg./Cm2). Approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant. (A) 110mm dia. (3.16.3)

40

282

11280

... More
3.17.9/S-3 P & F rigid PVC pipe fitting ( IS: 4985 make) of approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant. (A) Bend 87.5 110mm dia

12

161

1932

... More
E 1.1.1 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (A) Short point (up to 3 mtr.)

8

359

2872

... More
(B) Medium point (up to 6mtr). (E1.1.2)

10

578

5780

... More
(C) Long point (up to 10mtr).(E1.1.3)

10

772

7720

... More
E 1.3.1 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR on board.

10

357

3570

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (A) 2 x 2.5 sq. mm. + 1x1.5sqmm (E 4.1.7)

120

81

9720

... More
(B) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (E 4.1.14)

80

122

9760

... More
E 7.36 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. . For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

6

303

1818

... More
E 6.1.1.2 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6A to 32 A rating.single pole mcb

8

187

1496

... More
E 6.2.1.2 Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Double pole isolator 63 A rating

2

453

906

... More
Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3. powder painted complete with din rail  making internal DB  terminations with copper lugs,  detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Suitable for Six / Eight module for MCB/ RCCB. (E 6.9.2)

2

1099

2198

... More
Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(E 7.13)

8

30

240

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1170mm(+/-10%) LED batten with min. lumen output 2200 lm (E 17.1.1)

8

492

3936

... More
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. (E 5.9)

1

128

128

... More
Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. (E 7.20)

6

199

1194

... More
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value =4.0 to 4.5 ) (E 15.7.1)

6

1890

11340

... More
Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 8.0 Mtr long PCC pole of 200 Kg Working Load. (E 19.1.1)

3

3343

10029

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (A) 6.0 Sq. mm 2 core. (E 11.2.2.1)

50

128

6400

... More
(B) 4.0 Sq. mm 2 core. (E 11.2.1.1)

160

109

17440

... More
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 20 mm Dia. (E 18.18.1)

6

405

2430

... More
Labour charges for removing WVC pan Indian/orissa Pan (1.58.1)

2

227

454



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.