If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date27 Sep 2024
Closing Date23 Oct 2024
Tender Amount₹ 5,10,693 
Notes
Download

Costs

  • EMD

    ₹ 10,214
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 1,180

Summary

Work Of Construction Of 33/11 Kv Gss Giloth-ii At Riico Industrial Area And Erection Of 33 Kv Line Under Aen (htm), Behror On Arc Under Tn-78 In The Jurisdiction Of Kotputli Circle Of Jaipur Discom.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(2) Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.

-

-

-

... More
(2.1) Within 10 Kms.

12

4683

390.29

... More
(3) Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.

-

-

-

... More
(3.1) Within 10 Kms.

35

16614

474.71

... More
(4) Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading from store to site (these Charges will be 1.5 times for both sides)

-

-

-

... More
(4.1) 25 & 40 KVA

-

-

-

... More
(i) Within 10 Kms.

1

238

238.51

... More
(5) Safe Carriage of 33/11 KV Power Transformer

-

-

-

... More
(5.1) 5.0 MVA

-

-

-

... More
(i) Within 10 Kms

1

5081

5081.77

... More
(ii) Above 10 Kms & upto 30 Kms . Add for each Km or part thereof

1

1016

1016.2

... More
(6) Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores

-

-

-

... More
(6.1) Within 10 KMs.

6

5337

889.63

... More
(7) Safe loading of steel fabricated / unfabricated conductor drum & other line material.

15

3308

220.54

... More
(8) Safe unloading of steel fabricated/ unfabricated conductor drum & other line material.

15

1630

108.71

... More
(9) Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.

12.5

35298

2823.89

... More
(10) Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station.

30

94800

3160.02

... More
(11) Fixing of 11kv B&S / T&C type disc insulator for 33kv lines (each unit consiting of 3 nos. disc & 1set of H/W) on terminal point including fixing of hardware and strips.

6

281

46.96

... More
(12) Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 2 nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips.

6

201

33.63

... More
(13) Fixing of 33kv pin insulator with pins.

18

267

14.87

... More
(14) Fixing of 11kv pin insulator with pins.

30

297

9.92

... More
(15) Assembly, Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories complete in all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(15.1) G.O. switch without earthing blade.

-

-

-

... More
(i) 33kv G.O.switch

2

2224

1112.29

... More
(ii) 11kv G.O.switch

8

6920

865.1

... More
(16) Assembly and installation of Horn Gap fuse set (set of 3nos) on erected structure as per design, complete in all respect with post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(16.1) 33kv Horn Gap fuse set.

1

512

512.84

... More
(16.2) 11kv Horn Gap fuse set.

4

1779

444.96

... More
(17) Installation of lightening arrestors on erected structure / support (1 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(17.1) Sub-Station type

-

-

-

... More
(i) 33 KV L.A. each

3

512

170.95

... More
(18) Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(18.1) 25 and 40 KVA

1

621

621.01

... More
(19) Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / P.G.clamps. Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
(19.1) IN URBAN AREA

-

-

-

... More
(i) ACSR PANTHAR

0.5

3996

7993.24

... More
(20) Mesh earthing for 33/11 kv sub-station as per approved map &design usingMS flat 50X6mm/MS road 20mm dia includinglaying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:

-

-

-

... More
(20.1) Excavation of trench of 0.65 Mtrs.depth and 0.5 Mtr.width

-

-

-

... More
(i) Hard Soil

2

305

152.66

... More
(21) Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

200

5146

25.73

... More
(22) Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

200

7748

38.74

... More
(23) Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr. length as per design and requirment to be driven in earth by mechanical means and Providing & fastening of suitable clamps with the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:

-

-

-

... More
(23.1) Where drilling is not required

30

5709

190.31

... More
(24) Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.

200

1024

5.12

... More
(25) Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.

48

342

7.13

... More
(26) Pipe Erection for power Transformer at 33/11 KV S/S:- Supply & erection of earthing electrode shall consist of G.I. Pipe 100 mm,of 3 Mtr Length. The electrode shall be buried as far as practicable 3 meters below ground level. Wherever possible, earth electrodes shall be located as near the water tap, water drain or near down take pipe. Earth electrodes shall not be installed in proximity to a metal fence. It shall be kept clear of the buildings foundations and in no case it shall be nearer than 2 meters from the outer face of the wall. The electrode shall be surrounded with layer of charcoal dust and salt mixture through out the length. The 100 mm GI pipe shall be provided with holes of 12 mm dia. drilled at 75 mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a G.I. threaded cap for watering the earth through a pipe. A Clamp with Pati of 12" of M.S. Flat of size 50X6 mm shall be fixed (Bolted) on the top edge of the pipe which in turn shall be connected to Neutral / Body of the Power Transformer through M.S. Flat size 50X6 mm. The G.I. cap over the GI pipe shall be housed in a masonry chamber, approximately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC inspection cover resting over a RCC frame, embedded in masonry.

2

10234

5117.12

... More
(27) Laying of 1100 volt heavy duty armoured XLPE cable of aluminum coudctor of following size conforming to IS: 7098 (Pt-I) (latest amended) overhead service line from pole to meter terminals for release of new LT connections/replacement of damaged/obsolete service line (except agriculture one). The cable must be fixed on wall with clamps /hooks properly at a interval of one meter.

-

-

-

... More
(27.1) 4 Core 16/25 sq. mm

30

247

8.26

... More
(28) Erection of steel supports in the excavated pit in alignment after checking then same with plumb line as per approved design and drawing of 33/11KV Sub- station.The support should be grouted and muffed in cement concrete ratio 1:3:6 as per chapter -5 code No.5.7.The remaining portion of the pit will be back filled with soil.The charges for grouting & muffing will be paid by extra as per chapter code no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Store issue rates.

-

-

-

... More
(28.1) Fabricated structure AB type

3

5606

1868.9

... More
(28.2) Fabricated structure AB-1 type

6

11213

1868.9

... More
(28.3) Isolator / C.T.structure

2

3737

1868.9

... More
(29) Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
(29.1) 33 KV OCB

1

5013

5013.96

... More
(29.2) 11 KV VCB (Outdoor )

5

25069

5013.96

... More
(30) Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.

-

-

-

... More
(30.1) 2x2.5 Sq.mm.

400

5372

13.43

... More
(30.2) 4x2.5 Sq.mm.

400

7200

18

... More
(30.3) 12x2.5 Sq.mm.

200

4930

24.65

... More
(31) Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)

-

-

-

... More
(31.1) On new surface

100

3247

32.47

... More
(32) Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)

-

-

-

... More
(32.1) On new works with two coats.

100

4870

48.7

... More
(33) Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing.

-

-

-

... More
(33.1) Other steel items

20

88559

4427.99

... More
(34) Checking, tightening & replacement of jumpers, clamps connectors of bus bar including transformer & equipments of sub-station.Material to be provided by Nigam ,If required.

-

-

-

... More
(34.1) 33/11 KV S/S with 1 power transformer

1

1219

1219.03

... More
(35) Intallation of 33 KV Cable (XLPE) termination / straight through joints ( Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required.(Including crimping of lugs)

-

-

-

... More
(35.1) Outdoor end terminal

-

-

-

... More
(i) 3x240 Sq mm to 3x400 Sq mm

4

6311

1577.99

... More
(35.2) Straight through joint

-

-

-

... More
(i) 3x240 Sq mm to 3x400 Sq mm

1

3366

3366.4

... More
(36) Laying of 33 KV XLPE Cable ( Aluminium Conductor ) underground as per relevant ISS / JVVNL standard including excavation of 30 cm width x120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.

-

-

-

... More
(36.1) 3x240 Sq mm to 3x400 Sq mm

400

52604

131.51

... More
(37) Crane with driver and P.O.L

-

-

-

... More
(37.1) 18 T

20

19349

967.48

... More
(38) PURCHASE ITEMS (As per SIR 210 dated 09.05.2024):

-

-

-

... More
(38.1) PG Clamps for PANTHER

40

9890

247.25

... More
(38.2) T CLAMP FOR PANTHER CONDUCTOR

20

5414

270.7

... More
(38.3) Assorted Nut & Bolt

300

30978

103.26



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.