Jaipur Vidyut Vitran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Soon19 Dec 2024
Tender Amount₹ 6,00,000 
Notes
Download

Costs

  • EMD

    ₹ 12,000
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 590

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(B) Lattice Tower /Size of pit (for AB & AB1 STRUCTURE)

-

-

-

... More
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep

2

335

671.38

... More
(C)Stay set/Depth of pit

-

-

-

... More
8'x 3/4" -0.75x0.5x1.6 m

4

79

319.88

... More
Safe carriage of steel(fabrication and unfabricated) I.e.M.S. Rails,R.s. joists,M.S. channels,M.S.Angles,M.S. Flat,G.I.Stay Sets ,G.I. Stay wire,G.I. wire Nuts and bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam Store /at work Site.

-

-

-

... More
Within 10 Kms.

0.5

325

162.83

... More
Safe Carriage of insulator,hardware,Cable etc. including loading / unloading and stacking in Nigam Store etc.

-

-

-

... More
Within 10 Kms.

0.5

390

195.15

... More
safe carriage of fabricated lattice tower structures and sub stationbstructures type AB, AB beams, isolaters structures etc. including loading/unloading and stacking in the nigam.stores/at work site

-

-

-

... More
Within 10 Kms.

0.9

474

427.24

... More
Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.

-

-

-

... More
Lattice Structure

0.9

4888

4399.68

... More
Erection & fixing of G.I. Stay sets with anchor plates in excavated pit in required positions and back filling with soil with proper ramming.The work includes fixing of stay clamps,Stay insulators with stay wire at both ends with proper tention. Size of stay set/Stay wire.

-

-

-

... More
8"x3/4" with 7/8 SWG Stay wire

4

278

1115.24

... More
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm graded blast cruster broken in pit /foundation according to the size/type of supports/stay set including compaction/curing for 21 days in steel plates shuttering/ framer base.

2

2823

5647.78

... More
Supplying and laying of randum rubble stone boulder having weight not less than 20 kgs.( Note:- If the stay required to be grouted in cement then the rates as indicated in this item will be applicable & paid in addition to above rates and the charges for back filling with soil will be deducted @ 10.00 per cum.)

3.5

462

1619.69

... More
Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
Fixing of 11 KV B&S/T&C type disc insulator of 33 KV lines(each unit consiting of 3 nos. disc & 1 set of H/W ) on terminal point including fixing of hardware and strips.

6

46

281.76

... More
Fixing of 33 KV pin insulators with pins

6

14

89.22

... More
Assembly,Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulators and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevsiling Discom store issue rates.

-

-

-

... More
(A)G.O. switch with earthing blade.

-

-

-

... More
33kv G.O.switch

1

1235

1235.98

... More
Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
ACSR DOG

0.04

2915

116.6

... More
Part-2

-

-

-

... More
Levelling of ground

-

-

-

... More
Levelling of ground up to 30 cm. to 90 cm depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)

1500

6

10110

... More
Excavation of pit in hard soil which does not require blasting to erect various support and stay sets including stacking of excavated muck from the edge of excavation/pit

-

-

-

... More
(A) Height of poles/R.S.Joist/M.S. Rail Size of pit

-

-

-

... More
9 Mtr/ 1.2mx0.6mx1.50 m deep

4

102

409.15

... More
(B) Lattice Tower /Size of pit (for AB & AB1 STRUCTURE)

-

-

-

... More
11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep

23

335

7720.87

... More
(C)Stay set/Depth of pit

-

-

-

... More
8'x 3/4" -0.75x0.5x1.6 m

8

79

639.76

... More
Earth work excavation and foundation of platfrom of transformers and brakers including dressing of sides and ramming of bottoms .Liftup to 1.5 Meter including taking out the excavated soil and depositing and refilling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 Meter.

-

-

-

... More
Hard /dense soil

30

77

2311.2

... More
Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken ) in foundation plinth excluding the cost of shuttering using 1 cement:5 sand:10 aggregate mix.

1.5

2371

3556.78

-

-

-

... More
The rates are all lead of cement,lime,ballast, sand,surkhi and grit etc.at site of work.

-

-

-

... More
For all concrete work coarse sand shall be used no extra will be paid .

-

-

-

... More
Concrete mix prepared by power driven mechanical mixer shall be used .

-

-

-

... More
Under exceptional coditions, where mechanical mixer and vibrator are not used(with the approval of Engineer Incharge reduced by 3% for mechanical mixer and 2% for Vibrator

-

-

-

... More
Thickness of the cement concrete should not exceeed 100 mm.

-

-

-

... More
Plaster on new surface on walls in cement ,sand mortar 1:6 including racking of joint etc. complete fine finsh 25 mm thick.

30

128

3849.6

-

-

-

... More
The rates for complete work including racking of joints,curing,grinding,mixing and finishing T&P and scaffolding material and cost of material with all lead and lift.

-

-

-

... More
The rates cover protection of all place and things,requiring protection and cleaing such places and thing of all droppings and splashes of mortar etc.

-

-

-

... More
Masonry for foundation and plinth

-

-

-

... More
Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.

20

1924

38496.6

... More
Brick masonry for foundation and plinth in Cement sand mortar 1:6 ( 1 Cement : 6 Sand ) including labour charges.

20

2817

56350.4

... More
Safe carriage of PCC poles including loading /un-loading

-

-

-

... More
C) 9 Mtr. Long -400 kg

-

-

-

... More
Within 10 Kms.

4

194

777.84

... More
Safe carriage of steel(fabrication and unfabricated) I.e.M.S. Rails,R.s. joists,M.S. channels,M.S.Angles,M.S. Flat,G.I.Stay Sets ,G.I. Stay wire,G.I. wire Nuts and bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam Store /at work Site.

-

-

-

... More
Within 10 Kms.

3

325

976.95

... More
Safe Carriage of insulator,hardware,Cable etc. including loading / unloading and stacking in Nigam Store etc.

-

-

-

... More
Within 10 Kms.

2

390

780.58

... More
safe carriage of fabricated lattice tower structures and sub stationbstructures type AB, AB beams, isolaters structures etc. including loading/unloading and stacking in the nigam.stores/at work site

-

-

-

... More
Within 10 Kms.

10

474

4747.1

... More
Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site (These charges will be 1.5 times for both sides )

-

-

-

... More
b) 25 & 40 KVA

-

-

-

... More
Within 10 Kms.

1

238

238.51

... More
Safe Carriage of 33/11 KV Power Transformer

-

-

-

... More
b) 5.0 MVA

-

-

-

... More
Within 10 Kms

1

5081

5081.77

... More
Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores

-

-

-

... More
Within 10 KMs.

7

889

6227.41

... More
Erection & fixing of G.I. Stay sets with anchor plates in excavated pit in required positions and back filling with soil with proper ramming.The work includes fixing of stay clamps,Stay insulators with stay wire at both ends with proper tention. Size of stay set/Stay wire.

-

-

-

... More
8"x3/4" with 7/8 SWG Stay wire

8

278

2230.48

... More
Fixing of all type of fabricated material on erected Supports with nuts & bolts as per approved design & drawing of sub-station.

1.2

3160

3792.04

... More
Fixing of 11 KV B&S/T&C type disc insulator of 33 KV lines(each unit consiting of 3 nos. disc & 1 set of H/W ) on terminal point including fixing of hardware and strips.

36

46

1690.56

... More
Fixing of 11 KV pin insulators with pins

15

9

148.8

... More
Assembly,Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulators and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevsiling Discom store issue rates.

-

-

-

... More
(A)G.O. switch with earthing blade.

-

-

-

... More
33kv G.O.switch

1

1235

1235.98

... More
(B) G.O. Switch without earthing blade

-

-

-

... More
33 KV G.O. switch

2

1112

2224.58

... More
11 KV G.O. switch

7

865

6055.7

... More
Assembly and installation of Horn Gap fuse set (set of 3nos)on erected structure as per design, complete in all respectwith post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
33kv Horn Gap fuse set.

1

512

512.84

... More
11kv Horn Gap fuse set.

4

444

1779.84

... More
Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of steel structure set for sub-station as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
25 and 40 KVA

1

621

621.01

... More
Drawing of overhead ABC conductor (Areal bunched cable)on existing erected pole/support including laying. Jointing,stringing complete in all respect.

-

-

-

... More
1cX25 + 25 Sq mm

0.25

2067

516.86

... More
Earthing of 11/0.4 KV distribution transformer /sub-station with 3-pieces of M.S. Rod 20mm dia each 3 meter long and driving them into earth by mechanical means at a distance as per approved design & drawing & specification.The work includes flattening of top ends M.S. rod drilling a hole of 9/16" dia at flattened top and tightening of M.S. Flat 50x6mm (having 3 hole 2ends and 1mm middle ) with nuts and bolts with M.S.rods top end hole.The flat will also be welded with M.S.rod.The end will be connected to equipment as under in sequence.

3

224

673.86

... More
Mesh earthing for 33/11 kv sub-station as per approved map &design usingMS flat 50X6mm/MS road 20mm dia includinglaying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:

-

-

-

... More
Excavation of trench of 0.65Mtrs.depth and 0.5Mtr.width

-

-

-

... More
Hard Soil

40

152

6106.4

... More
Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

200

25

5146

... More
Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

100

38

3874

... More
Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and Providing & .fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:

-

-

-

... More
Where drilling is not required

27

190

5138.37

... More
Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.

150

5

768

... More
Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.

200

7

1426

... More
Pipe Earthing for Power Transformer at 33 / 11 KV S/S:- Supply & erection of earthing electrode shall consist of G.I. Pipe 100 mm,of 3 Mtr Length. The electrode shall be buried as far as practicable 3 meters below ground level. Wherever possible, earth electrodes shall be located as near the water tap, water drain or near down take pipe. Earth electrodes shall not be installed in proximity to a metal fence. It shall be kept clear of the buildings foundations and in no case it shall be nearer than 2 meters from the outer face of the wall. The electrode shall be surrounded with layer of charcoal dust and salt mixture through out the length. The 100 mm GI pipe shall be provided with holes of 12 mm dia. drilled at 75 mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a G.I. threaded cap for watering the earth through a pipe. A Clamp with Pati of 12" of M.S. Flat of size 50X6 mm shall be fixed (Bolted) on the top edge of the pipe which in turn shall be connected to Neutral / Body of the Power Transformer through M.S. Flat size 50X6 mm. The G.I. cap over the GI pipe shall be housed in a masonry chamber, approximately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC inspection cover resting over a RCC frame, embedded in masonry.

2

5117

10234.24

... More
Erection of steel supports in the excavated pit in alignment after checking then same with plumb line as per approved design and drawing of 33/11KV Sub- station.The support should be grouted and muffed in cement concrete ratio 1:3:6 as per chapter -5 code No.5.7.The remaining portion of the pit will be back filled with soil.The charges for grouting & muffing will be paid by extra as per chapter code no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Store issue rates.

-

-

-

... More
Fabricated structure AB type

4

1868

7475.6

... More
Fabricated structure AB-1 type

6

1868

11213.4

... More
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.

21.9

2823

61843.12

... More
Supplying and laying of randum rubble stone boulder having weight not less than 20 kgs.( Note:- If the stay required to be grouted in cement then the rates as indicated in this item will be applicable & paid in addition to above rates and the charges for back filling with soil will be deducted @ 10.00 per cum.)

6

462

2776.61

... More
Erection of PCC poles in excavated pit in alignment after checking the same with plumb line as per approved design & drawing of 33/11kv sub-station.The pit should be back filled with the soil with proper ramming below 30cm ground level and then muffed above 15cm average ground level with cement concrete ratio1:3:6.The charges for muffing will be paid extra as per chapter code no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made at the prevailing store issue rates.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
PCC Poles 9 Mtr. Long

4

537

2148.44

... More
Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.

-

-

-

... More
ACSR DOG/RABBIT

800

23

18776

... More
Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
33 KV VCB (Outdoor )

1

5013

5013.96

... More
11 KV VCB (Outdoor )

6

5013

30083.76

... More
Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.

-

-

-

... More
2x2.5 Sq.mm.

50

13

671.5

... More
Installation of metering points on 11 KV Out going feeder at 33/11 KV S/S.

3

19775

59326.17

... More
The installation work to be carried out as per drawing/design, under the supervision of concerned Assistant Engineer

-

-

-

... More
(a) Mounting structure

-

-

-

... More
The requisite steel members will be supplied by contractor including the hardware. Contractor shall joint/weld the members to form the mounting structure as per drawing. Necessary tools, welding, machines, lifting devices etc. shall be arranged by contractor.

-

-

-

... More
(b) Civil works

-

-

-

... More
Erection of lattices in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing for period as required (21 days). Area of concreting will be as per the drawing.

-

-

-

... More
( c ) Metering Equipments:

-

-

-

... More
The requisite metering equipments (CTPT set, meter,meter box & suitable conductors for jumpers), will be provided by the concerned Assistant Engineer in healthy condition at site. The cables from CTPT set to meter box laid down in 50 mm GI pipe with suitable bends & nipples, shall be provided by contractor alongwith the consumable items such as PVC tapes, petroleum jelly etc. The cable should be PVC multi strand copper 4 core 2.5/4 Sq. mm ISI marked and firm & tight connections shall be made by suitable connector e.g. at CTPT sets by using clamps and at meter/TTB by suitable lugs etc. The CTPT sets so installed shall be earthed by means of the MS Flat (size 50x6 mm) by joining it with the nearest earthing available at the sub-station. Requisite earthing material shall be made available by the contractor.

-

-

-

... More
(d) Meter:

-

-

-

... More
Meters should be fixed firmly inside the tamper proof box, as per drawing. All the meter fixture will be provided by contractor including all consumables.

-

-

-

... More
(e) Meter Box

-

-

-

... More
The meter box shall be provided by the concerned Assistant Engineer. However, hardware or any other items required to fix the meter inside the meter box will be provided by contractor. The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box.

-

-

-

... More
(f) Painting:

-

-

-

... More
All surfaces interior and exterior of lattice structure shall be white aluminum painted.

-

-

-

... More
(g) Commissioning of Metering Equipments:

-

-

-

... More
Installed meters inside the box and metering equipments duly mounted on the mounting structure will be powered up by connecting load in the presence of the concerned Assistant Engineer who will arrange the necessary shut down. The completion certificate shall be furnised by contractor.be filled accordingly. Since the work involves higher A.C. voltage level, the contractor shall take full care regarding safety norms, so as to avoid any accidental hazards.

-

-

-

... More
Fabrication of steel structures of M.S. angle ,M.S. channel & M.S. Flat including cutting, drilling and continunous welding joint as per design and drawing.

-

-

-

... More
Other steel items

1.2

4427

5313.59

... More
Laying of 11 KV, XLPE, Cable (Aluminium conductor) underground as per relevant IS/JVVNL standards including excavation of 30 cm x 120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class bricks covering refilling soil in the remaining(Including fixing of G.I.Pipe of required size at both end with 3 Mtr projected above the ground surface & 0.3 Mtr. below ground level)

-

-

-

... More
b) 3x240 Sq mm to 3x400 Sq mm

100

107

10754

... More
Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required

-

-

-

... More
(A) Outdoor end Terminal (ii) 3x240 Sq mm to 3x400 Sq mm

4

1205

4820.32

... More
Part-3

-

-

-

... More
Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.

2.7

199

539.41

... More
Excavation of pit in ordinary rock which does not require blasting/murrad to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.

-

-

-

... More
(A) Height of poles/R.S. Joist/m.s.rail Size of pit

-

-

-

... More
9 Mtr/ 1.2mx0.6mx1.50m deep

52

255

13297.44

... More
(B) Lattice TOWER /Size of Pit

-

-

-

... More
11.4/10.8 Mtr/1.5m*1.80 m deep

4

1310

5242.04

... More
©Stay set/Depth of Pit

-

-

-

... More
6'x 5/8" -0.75x0.5x1.35 m

17

209

3556.57

... More
Safe carriage of PCC poles including loading /un-loading

-

-

-

... More
C) 9 Mtr. Long -200 kg

-

-

-

... More
Within 10 Kms.

52

194

10111.92

... More
Safe carriage of steel(fabrication and unfabricated) I.e.M.S. Rails,R.s. joists,M.S. channels,M.S.Angles,M.S. Flat,G.I.Stay Sets ,G.I. Stay wire,G.I. wire Nuts and bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam Store /at work Site.

-

-

-

... More
Within 10 Kms.

3

325

976.95

... More
Safe Carriage of insulator,hardware,Cable etc. including loading / unloading and stacking in Nigam Store etc.

-

-

-

... More
Within 10 Kms.

0.5

390

195.15

... More
safe carriage of fabricated lattice tower structures and sub stationbstructures type AB, AB beams, isolaters structures etc. including loading/unloading and stacking in the nigam.stores/at work site

-

-

-

... More
Within 10 Kms.

1.8

474

854.48

... More
Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.

-

-

-

... More
Lattice Structure

1.8

4888

8799.35

... More
Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
PCC Poles 9 Mtr. Long (200Kg)

42

488

20503.98

... More
Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of complete steel structure for line D.P.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.

-

-

-

... More
PCC Poles 9 Mtr. Long(200 Kg.)

5

1105

5525

... More
Erection & fixing of G.I. Stay sets with anchor plates in excavated pit in required positions and back filling with soil with proper ramming.The work includes fixing of stay clamps,Stay insulators with stay wire at both ends with proper tention. Size of stay set/Stay wire.

-

-

-

... More
6"x5/8" with 7/10 SWG Stay wire

17

241

4102.27

... More
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement river sand and 12 mm to 20 mm graded blast cruster broken in pit /foundation according to the size/type of supports/stay set including compaction/curing for 21 days in steel plates shuttering/ framer base.

4

2823

11295.56

... More
Supplying and laying of randum rubble stone boulder having weight not less than 20 kgs.( Note:- If the stay required to be grouted in cement then the rates as indicated in this item will be applicable & paid in addition to above rates and the charges for back filling with soil will be deducted @ 10.00 per cum.)

25

462

11569.25

... More
Fixing of 11 KV B&S/T&C type disc insulator of 11 KV lines(each unit consiting of 1 nos. disc & 1 set of H/W ) on terminal point including fixing of hardware and strips.

33

22

736.38

... More
Fixing of 11 KV pin insulators with pins

147

9

1458.24

... More
Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
ACSR WEASAL

8.04

1454

11697.8

... More
Laying , jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(A) IN URBEN AREA

-

-

-

... More
G.I.Earth wire 6 SWG

3.05

1023

3121.19

... More
Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod 20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discom store issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)

15

335

5028.37



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.