Jaipur Vidyut Vitran Nigam Limited Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Eprocure
Opening Date6 Feb 2025
Closing Date24 Feb 2025
Tender Amount₹ 65,05,244 
Notes
Download

Costs

  • EMD

    ₹ 1,30,105
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 1,770

Summary

Electric Work Under Tn-95

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BID SUBMISSION DATE - 12/02/2025, BID LAST DATE - 24.02.2025 AND BID OPENING DATE - 25.02.2025.
PRICE BID DOCUMENTS.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Pipe Earthing for Power Transformer as 33/11 KV S/S:- Supply & erection of earthing elecctrode shall consist of G.I. Pipe 100 mm of 3 Mtr. Length. The electrode shall be buried as far as practicalbe 3 meter below ground level. Wherever possible, earth electrodes shall be located a near the water tab, water drain or near down take pipe, Earth electrodes shall not be installed in proximlty to a metal fence. It shall be kept clear of the building foundations and in no case it shall be nearer than 2 meters from the outer face of the wall. The electrode shall be surrounded with layer of charooal dust and salt mixture through out the length. The 100 mm GI pipeshall be provided with holes of 12 mm dia driled at 75 mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a GI threaded cap for watering the earth thourgh a pipe. A Clamp with Pati of 12" of MS Flat of size50s6 mm shall be fixed (Bolted) on the top edge of the pipe which in turn shall be connected to Neutral/ Body of the Power Transformer through MS Flat size 50x6 mm. The GI cap over the GI pipe shall be housed in a masonry chamber, approxmately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC inspection cover resting over a RCC frame, embedded in masony.

4

5117

20468.48

... More
Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
Normal soil

140

121

16966.6

... More
Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
Lattice Structure

5.5

3410

18755.11

... More
(I) Indoor end terminal 3x35 Sq mm to 3x185 Sq mm

9

946

8522.01

... More
18 Nos. terminal blocks of 30 Amp. Bolted type with end plate and screws fixed on 36 cm mounting channel for terminal block with bolts & nuts of 25x9 Sq.mm.on side support inside junction box. The terminal blocks should be detachable type, which can be removed or added individually and suitable for 4/6 Sq.mm.coppers lugs. The terminal blocks should be preferably of GEC/Alsthom/ Essun/Malamin PVC or equivalent make.

-

-

-

... More
8'x 3/4" -0.75x0.5x1.6 m

-

-

-

... More
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep

-

-

-

... More
Excavation of pit in Hard soil.(15% extra shell be payable for the designated desert area panchayat samities of Jodhpur Discom in pursuance to Jdvvnl order No. 1240 dt.18.07.13 )

-

-

-

... More
Supply andFixing of metallic junction box size 450x300x250 mm outdoor type floor mounting fabricated out of cold rolled steel sheet 16 SWG with required branching and support of M.S. Angle 45x45x5mm The box should be printed with the coat of Zinc Chromate primer and 2 coats of light grey paint. Removal of gland plate of 3 mm. Thickness with rubber gasket for cable entry at bottom gland plate should be spacious to fix 6 Nos. cable glands of 25mm size double hinged door with pad lock provision should be gasket with foam & rubber to make junction box dust & water proof supply of junction box will include following items.

1

2543

2543.88

... More
Other steel items

1.5

4427

6641.99

... More
Thickness of the cement concrete should not exceeed 100 mm.

-

-

-

... More
Safe Carriage of 33/11 KV Power Transformer

-

-

-

... More
(ii) 3x240 Sq mm to 3x400 Sq mm

41

3366

138022.4

... More
ACSR DOG/RABBIT

200

23

4694

... More
Erection & commissioning of battery set and battery charger including all required connection/wiring from battery set to battery charger and A.C.mains complete in all respect.

-

-

-

... More
(I) Outdoor end terminal 3x35 Sq mm to 3x185 Sq mm

23

1032

23757.62

... More
(B) Lattice Tower /Size of pit

-

-

-

... More
(B) Lattice Tower /Size of pit

-

-

-

... More
(A)sub-station type

-

-

-

... More
Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6(1 Cement : 6 Sand) including labour charges.

54

1924

103940.82

... More
Supply & Erection of Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. The value of Earth resistance shall be obtained 0.5 Ohm in individual earthing. G.I Pipe (IS: 1239 marks) GI pipe 3000 mm long, 80 I 40 mm, Terminal 12 mm GI Strip. Earthing as per 18:3043-1987

4

6767

27069.88

-

-

-

... More
Under exceptional coditions, where mechanical mixer and vibrator are not used(with the approval of Engineer Incharge reduced by 3% for mechanical mixer and 2% for Vibrator

-

-

-

... More
If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm O/D Joint) Rate - 3632.69 Rs

26

3995

103894.93

... More
Installation of 33 KV Cable (XLPE) termination / straight through joints ( Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required.(Including crimping of lugs)

-

-

-

... More
(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.

-

-

-

... More
33 KV L.A. set

2

170

341.9

... More
Laying of HT/LT control cable installation of C&R panel Kiosks Breakers etc.

-

-

-

... More
Concrete mix prepared by power driven mechanical mixer shall be used .

-

-

-

... More
110 Volts D.C.

1

1236

1236.88

... More
The top cover of junction box should have slope of 10 mm so that water is not collected on top of the box.

-

-

-

... More
On new surface

400

32

12988

... More
Erection of 11 KV RMU complete with accessories on existing foundation including use of special tools & conducting all pre-commissioning test before energization,connecting the cables etc. complete in all respect with erection & grouting of structure (excluding civil works for which payment shall be made extra as per clause No. 2.6 of CLRC). The relays will be tested by Discom.

1

4062

4062.97

... More
B) 33 / 11 KV below 3C x 300 Sq.mm cable

-

-

-

... More
(ii) 3x240 Sq mm to 3x400 Sq mm

4

1157

4628.64

... More
(A) Height of poles/R.S.Joist/M.S. Rail Size of pit

-

-

-

... More
The rates for complete work including racking of joints,curing,grinding,mixing and finishing T&P and scaffolding material and cost of material with all lead and lift.

-

-

-

... More
Mesh earthing for 33/11 kv sub-station as per approyed map &design using MS flat 50X6mm/MS road 20mm dia including laying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints structJres & equipments etc. as under:

-

-

-

... More
For all concrete work coarse sand shall be used no extra will be paid .

-

-

-

... More
(ii)33/11 KV below 3CX300 Sqmm.

8810

182

1609234.6

... More
Safe loading of steel fabricated / unfabricated conductor drum & other line material.

1.5

220

330.81

... More
Within 10Kms.

5.5

474

2610.9

... More
3.5 Core 50 Sq.mm.to 95 Sq.mm.

20

33

673.2

... More
The rates cover the preparation and cleaing of all places

-

-

-

... More
b) 25 & 40 KVA

-

-

-

... More
11.4/10.8Mtr/1 .5mx1 .5m x1.80 m deep

16

305

4882.56

... More
Masonry for foundation and plinth

-

-

-

... More
(C) Fixing of PG clamp of Panther Conductor

10

7

79.1

... More
If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm S/TJoint) Rate - 3108.89 Rs

38

3419

129951.6

... More
Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

500

25

12865

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.orpart thereof.

220

111

24508

... More
(B)GO. switch . without earthing blade

-

-

-

... More
Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE /PILCA Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required

-

-

-

... More
If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm I/D Joint) Rate - 1009.90 Rs

4

1110

4443.56

... More
For Extra loop (Ghera) to be provided near the pole on termination point and the length of cable along the pole for mounting of cable jointing kit

-

-

-

... More
11.4/10.8Mtr/1 .5mx1 .5m x1.80 m deep

6

335

2014.14

... More
(i) Straight through joint 3x50 Sq mm to 3x185 Sq mm

-

-

-

... More
8 Mtr/R.S.Joist/M.S. Rail 1.2mx0.6mx1.35 m deep

-

-

-

... More
(c) 5.0 MVA

-

-

-

... More
8 Mtr/R.S.Joist/M.S. Rail 1.2mx0.6mx1.35 m deep

4

87

349.04

... More
Excavation of pit in soil (ordinary) to erect various supports and stay sets including stacking of excavated soil from the edge of excavation (15% extra shall be payable for the designated desert area panchayat samities of Jodhpur Discom in pursuance to JdVVNL order No. 1240 dt. 18.07.13).

-

-

-

... More
Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)

-

-

-

... More
Safe unloading of steel fabricated/ unfabricated conductor drum & other line material.

1.5

108

163.07

... More
11kv G.O.switch

14

865

12111.4

... More
Erection of LT Distribution piller Boxes of 800/400/160/100 Amps. Capacity.Each 37"x24" base as per JVVNL standard including excavation,bricks,sand,cement masonary of size 4"x3"x10"and 3' in ground and 1 1/2'above road level with muffing to support and mounting the piller .Themasonary will have 4" X 4" opening 2"below ground level two in the rear sideand one each in the remaining sides to facilitate entry and exist of incomingand outgoing PVC cable.Earthing of the piller shall be connected to DPearth with 7/10 SWG StayWire & lugs.

-

-

-

... More
Within 10 Kms.

220

390

85863.8

... More
(ii) 3x240 Sq mm to 3x400 Sq mm

26

1577

41027.74

... More
3x35 Sq mm to 3x185 Sq mm

640

91

58668.8

... More
Within 10 Kms.

1

238

238.51

... More
B) When the road cutting is not permitted by the local administration.

-

-

-

... More
Laying, connecting, testing and commissioning of 1100 Volt PVC cable at 33/11 KV Sub-Station including connections of leads cutting stripping of cable insulation providing compression type terminals fixing of cable glands crimping of lugs clamping of cable cores etc. complete in all respect as per requirement of Engineer Incharge. PVC cable size.

-

-

-

... More
ACSR PANTHER

-

-

-

... More
Safe Carriage of 33/11 KV Power Transformer

-

-

-

... More
Providing and fixing of G.I. Pipe B-Class (IS:1239 marks) at the starting and finishing point of 33 & 11 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.

-

-

-

... More
Safe carriage of steel( fabricated and unfabricated} l.e.M.S. Rails, RS.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.l.Stay Sets, G.I. Stay Wire, G.l.Wire Nut & Bolts etc. and ACSR Conductorincluding loading and unloading and stacking in Nigam store /at work site

-

-

-

... More
(ii) 3x240 Sq mm to 3x400 Sq mm

2

1205

2410.16

... More
25 mm thick with 12.5 mm thick nominal size aggregate.

40

167

6695.6

... More
11 KV VCB (Indoor )

10

4062

40629.7

... More
A) 33 / 11 KV 3C x 300 Sq.mm cable

8750

302

2644950

... More
Installation of lightening arrestors on erected structure /support (set of 1 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
Providing and fixing of G.I. Pipe of 150 mm diameter. B-Class (IS:1239 mark),at the starting and finishing point of 33 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.

25

1559

38988.5

... More
12x2.5 Sq.mm.

160

24

3944

... More
If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm I/D Joint) Rate - 3526.48 Rs

7

3879

27153.9

... More
Cement concrete flooring grade 1 :2:4 ( 1-cement :2-coarse sand :4-graded stone aggregate ) rounding off edges etc.but excluding cost of nosing of steps etc.complete.

-

-

-

... More
If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm S/T Joint) Rate - 10787.76 Rs

41

11866

486527.98

... More
3x240 Sq mm to 3x400 Sq mm

160

103

16502.4

... More
The rates cover protection of all place and things,requiring protection and cleaing such places and thing of all droppings and splashes of mortar etc.

-

-

-

... More
33 KV G.O (800Amps)

-

-

-

... More
33KV ISOLATOR CLAMP (PG CLAMP)

42

251

10573.5

... More
3x240 Sq mm to 3x400 Sq mm

800

223

178768

... More
33 kv G.O.switch

14

1112

15572.06

... More
If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm O/D Joint) Rate - 1032.68 Rs

23

1135

26126.8

... More
33 KV VCB/SF-6 Breaker

8

5013

40111.68

... More
Above 10 Kms. & upto 30 Kms. Add for each Km. or part thereof.

3.5

92

322.7

... More
Where drilling is not required

110

190

20934.1

... More
Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.

-

-

-

... More
(I) Straight through joint 3x35 to 3x185 Sq mm

38

2151

81768.78

... More
Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates

-

-

-

... More
Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.

150

7

1069.5

... More
Above 10 Kms. and upto 30 Kms.Add per each km,or part thereof

19

230

4377.6

100

806

80622

... More
Erection & fixing of steel struts in the excavated pit in position.The top end of the strut will be properly holed/welded with the main support muffed in cement concrete of ratio 1:3:6 as per item No.5.7.The nuts and bolts will be provided by the contractor as per Nigams specification for which payment will be made at the prevailing store issue rate.The cost of muffing and grouting will be paid extra.

-

-

-

-

-

-

... More
The rates are all lead of cement,lime,ballast, sand,surkhi and grit etc.at site of work.

-

-

-

... More
A) When the passages available for laying the proposed cable is totally a metal or cement concrete road.

-

-

-

... More
Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken ) in foundation plinth excluding the cost of shuttering using 1 cement:5 sand:10 aggregate mix.

50

2371

118559.5

... More
Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.

-

-

-

... More
(ii) 3x240 Sq mm to 3x400 Sq mm

7

1262

8836.45

... More
Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earthmesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

200

38

7748

... More
To Supply & Replace the damaged / defective parts of 33 KV G.O switch (proper shut down will be provided by Nigam), Rates are inclusive of material,

-

-

-

... More
100 AMP.

1

2212

2212.35

... More
Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be drlven in earth by mechanical means and Providing & fastening of suitable clampswith the M.S. rod , connection of earth wire/stay wire/MS flat in clamp depending on type of soil

-

-

-

... More
(I) Indoor end termination

-

-

-

... More
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep

-

-

-

... More
(C)Stay set/Depth of pit

-

-

-

... More
Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores

-

-

-

... More
Above 10 Kms & upto 30 Kms . Add for each Km or part thereof

2

1016

2032.4

... More
(I) Outdoor end terminal

-

-

-

... More
If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X300sqmm O/D Joint) Rate - 1133.10 Rs

2

1246

2492.82

... More
(ii) When the road cutting is not permitted by the local administration.

-

-

-

... More
The rates for all items inculde all form of work, laying, curing and finishing etc. The rates are for complete work at site, inclusive of all leads.

-

-

-

... More
The supports of junction box made of M.S.Angle size 45x45x5mm with cleat having 1.2 meter length of each support should be grouted in cement concrete ratio 1:3:6.

-

-

-

... More
Above 10 Kms. & upto 30 Kms. Add for each Km.orpart thereof.

5.5

92

507.1

... More
75 mm thick with 20 mm thick nominal size aggregate

10

398

3989.2

... More
Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod20mm dia each 3 meter long and driving into earth by mechanical means as per approved design.Drawing &specification.All material except MS rod,MS flat & stay wirewill be supplied by the contractor.If material is supplied by the contractor ,the payment will be made as per prevailing Discomstore issue rates.(In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)

24

335

8045.28

... More
Within 10 KMs.

19

889

16902.97

... More
33 KV Cable:-

-

-

-

... More
Excavation of trench of 0.65 Mtrs. depth and 0.5 Mtr. width

-

-

-

... More
Craine with driver and P.O.L

-

-

-

60

967

58048.8

... More
On new works with two coats.

400

48

19480

... More
Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading from store to site (these Charges will be 1.5 times for both sides)

-

-

-

... More
2x2.5 Sq.mm.

150

13

2014.5

... More
Within 10 Kms

2

5081

10163.54

... More
R.S.Joists

1.5

1722

2584.13

... More
Fabrication of steel structures of M.S angle,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing

-

-

-

... More
25 and 40 KVA

1

621

621.01

... More
Within 10 Kms

3.5

325

1139.77

-

-

-

... More
When cable laying through manual trench less (Bogie)

-

-

-

... More
Plaster on new surface on walls in cement ,sand mortar 1:6 including racking of joint etc. complete fine finsh 25 mm thick.

110

128

14115.2

... More
Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine "VERMIER".(120 cm deep).Use of this technology must be restricted to the situation like:-

-

-

-

... More
If the Cable Jointing Kits of HT , LT are not available with Nigam, then the unit officr will obtain NAC from ACOS & the contractor will supply the same as per latest SIR plus 10% (profit) of approved vendors (Amount With 10%) (3X185sqmm I/D Joint) Rate - 910.55 Rs

9

1001

9014.45

... More
11 KV Cable:-

-

-

-

... More
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)

-

-

-

... More
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams,isolators structures etc. including loading/unloading and stacking in the Nigam Stores /at work site.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.