If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Jaipur Vidyut Vitran Nigam Limited - JVVNL Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date2 Sep 2024
Closing Date9 Sep 2024
Tender Amount₹ 75,00,000 
Notes
Download

Costs

  • EMD

    ₹ 1,50,000
  • Document Cost

    ₹ 1,770
  • Tender Fee

    ₹ 1,500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (B/3.1.6)

120

396240

3302

... More
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). (B/6.1.6)

62

175956

2838

... More
Random rubble dry stone kharanja under floor (B/11.26)

146

136072

932

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Cold twisted deformed bars (IS:1786). (B/4.13.2)

3899

300223

77

... More
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. (B/4.9)

44

6908

157

... More
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix (B/4.1)

17

83878

4934

... More
Brick work with clay flyash F.P.S. brick (IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : in Cement mortar 1 : 6 (1 cement : 6 coarse sand). (B/5.15.2)

37

178784

4832

... More
Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) (B/5.8.3)

59

31034

526

... More
Add extra for Square or Rectangular Pillars in superstructre flyash Brick work upto three storey : (A) Upto 45 cm length and two corners are free. (B/5.3.2)

3.95

643

163

... More
Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in :Cement Mortar 1:6 ( 1-Cement : 6-Sand). (B/6.2.6)

59

205261

3479

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix/Design Mix (B/4.3)

20

103700

5185

... More
Add extra for Random Rubble stone masonry with hard stone in

-

-

-

... More
(A) Walls upto 30 cm and less thickness. (B/6.3.4)

46

8556

186

... More
(B) Square or rectangular Pillars. (B/6.3.1)

13

2249

173

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. (B/4.10.2)

159

54060

340

... More
Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. (B/17.1)

84

57876

689

... More
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : (A) Window side hung / ventilator top or center hung. (B/9.19.3)

15

47025

3135

... More
Providing and fixing Square bars or other flat welded to window, ventilatiors etc. (B/9.27)

70

4550

65

... More
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. (B/9.26)

15

9255

617

... More
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint Add extra for double leaf shutters. (B/9.17+9.17.1)

15

51642

3442.8

... More
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting (height upto 10m), fixing in position and applying a priming coat of approved steel primer all complete. (B/9.1)

1553

111816

72

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. (B/1.31)

800

4000

5

... More
Repair of existing steel grazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding machine and TP etc complete. (B/13.23)

30

9960

332

... More
S&F in walls machine cut and polished stone shelves, tands and sills in CM 1:3 with machine cut edges :

-

-

-

... More
(A) Kota stone minimum 30mm thick.: (B/6.17.3)

67

40803

609

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete.75mm thick with 20mm thick nominal size aggregate. (B/11.3.2)

22

10076

458

... More
Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification : (B/3.8)

127

46609

367

... More
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab from 2001 to 5000 Sqcm. (B/11.19.2)

5

5010

1002

... More
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' 30mm thick, commercial veneer both side. (B/8.13.2.1)

7

12887

1841

... More
Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. (B/8.14)

7

987

141

... More
Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) (a)M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc.( As per table 1 of IS 15658:2006 (b)Category ‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP 63:2004 (c) Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used. (d) Add extra over rates of item No. 11.38, A to C if colored paver blocks are used. (B/11.38.1(B)+11.39+11.40)

70

71526

1021.8

... More
Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) (a)M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc. (b)Category ‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP 63:2004 (c) Add extra over item No. 11.38, A to C if reflective paver block, manufactured with wet cast vibration system in two layers is used. (d) Add extra over rates of item No. 11.38, A to C if colored paver blocks are used. (B/11.38.3(B)+11.39+11.40)

644

887432

1378

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.

-

-

-

... More
(A) Two or more coats on new work. (B/12.46.1)

228

15732

69

... More
(B) One or more coats on old work. (B/12.46.2)

300

10200

34

... More
Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size. (B/7.12+7.15)

81

60053

741.4

... More
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).(B/7.13)

16

11968

748

... More
Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). (B/10.17.1)

7

31381

4483

... More
Supplying and fixing stone lintels/bed plates of approved quarry rough dressed in cement mortar 1:4 :Upto 15 cm. thick. (B/6.18.1)

0.2

1924

9621

... More
Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finished :

-

-

-

... More
(A) 20mm thick. (B/12.3.2)

519

98610

190

... More
(B) 12mm thick. (B/12.3.3)

199

31840

160

... More
(C) 25mm thick. (B/12.3.1)

600

126600

211

... More
6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) (B/12.5)

115

15985

139

... More
Providing Gola 75mmx75mm in CC 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with CM 1:3 (1 cement: 3 coarse sand) as per standard design. (B/10.22)

93

10323

111

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer. (B/12.37.1)

1235

92625

75

... More
Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work (B/12.43.1)

1679

206517

123

... More
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) :

-

-

-

... More
(A) New Plastered Surface (three or more coats) (B/12.22.1)

613

51492

84

... More
(B) Old Plastered Surface (two or more coats) (B/12.22.2)

1600

73600

46

... More
Applying priming coat with ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. (B/12.45.1)

14

406

29

... More
Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand): Raised and cut pointing. (B/12.31.2)

506

117898

233

... More
Repair to stone masonry in CSM 1:6 with old and new stone. (B/13.12)

120

38160

318

... More
P&F rigid PVC pipe (IS:4985 mark) class-II/(4kg/Cm2) approved quality/ make including joining the pipe with solvent cement rubber ring and lubricant :

-

-

-

... More
(A) 75 mm dia. (S/3.16.2)

5

885

177

... More
(B) 110mm dia. (S/3.16.3)

85

23970

282

... More
P&F rigid PVC pipe fittings (IS:4985 mark) of approved quality/make including joining the pipe with solvent cement rubber ring and lubricant :

-

-

-

... More
(A) Coupler (Socket).110mm dia. (S/3.17.1(ii))

5

540

108

... More
(B) Plain Tee. (S/3.17.3.ii)

5

935

187

... More
(C) Bend 45° (S/3.17.8.ii)

20

2560

128

... More
(D) Pipe Clip.110mm dia. (S/3.17.15(ii))

20

720

36

... More
P&F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: 580x440mm. (S/1.2.2)

4

12320

3080

... More
P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (small) size 456x355x265mm. (S/1.14.1)

4

7328

1832

... More
P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :: size 550x400 mm. (S/1.36.3)

5

12990

2598

... More
Providing and fixing 3-layer PP-R (Polypropylene random coplymer) pipes SDR 7.4 UV stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings and fixing the pipe with clamps at 1 metre spacing. This includes cost of cutting chases and making good the same including testing of joint complete as per direction of Engineer - in charge.(CONCEALED WORK INCLUDING CUTTING CHASES AND MAKING GOOD THE WALL ETC.)

-

-

-

... More
(A) PN-16 Pipe, 20 mm OD. (S/2.35.2)

40

10600

265

... More
(B) PN-16 Pipe, 25 mm OD. (S/2.35.3)

40

13680

342

... More
Providing and fixing 3-layer PP-R (Polypropylene random coplymer) pipes SDR 7.4 UV stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings including trenching, refilling and testing of joint complete as per direction of Engineer - in charge. (EXTERNAL WORKS)

-

-

-

... More
(A) PN-16 Pipe, 25 mm OD. (S/2.36.3)

70

18340

262

... More
(B) PN-16 Pipe, 32 mm OD. (S/2.36.4)

80

30080

376

... More
P&F bib cock (IS : 8931 mark), Superior quality of approved make :

-

-

-

... More
(A) CP Brass bib cock 15mm nominal bore. (S/2.7.3)

9

5310

590

... More
(B) PVC heavy duty 15mm nominal bore. (S/2.7.2)

1

106

106

... More
P&F Inlet connection (Angle Valves) Superior quality of approved make for wash basin, Gyser etc. CP Inlet connection 15mm brass(IS:8931 mark). (S/2.12.1)

6

3006

501

... More
P&F ball cock (IS : 1703 mark) with rod & PVC ball complete : Brass wt. not less than 300gm 15mm. (S/2.11.1)

5

1570

314

... More
P&F 15mm dia. Connection pipe of approved quality/make: PVC pipe with CP brass nuts upto lenth 300mm. (S/2.13.1)

6

438

73

... More
P&F Full-way wall valve (IS : 778 mark) or wheel valve of approved make :

-

-

-

... More
(A) Gun-metal 15mm nomimal bore. (S/2.15.1)

4

908

227

... More
(B) Gun-metal 25mm nomimal bore. (S/2.15.3)

6

3174

529

... More
P&F PVC storage tank ISI marked (IS:12701 marked indicating the BIS license no.) of approved make with cover, 25mm dia. 1M long GI over flow pipe and 25cm long washout pipe with plug & socket, including making connection etc., complete of approved design. 500litre capacity. (S/2.26.3)

4

15680

3920

... More
P&F SC floor trap (Nahni) of (IS:1729 mark) of approved Quality/make with socket down or hinged grating incld. Cutting and making good the floor : size 100x100 mm. (S/3.12.1)

8

6656

832

... More
P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type : Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm. (S/3.5.1)

3

3450

1150

... More
P&F Flush Cock/Flush Valve (IS : 9758 Mark) for WC of approved quality make : Brass/Gun metal Half-turn wt. 1 Kg. of approved quality /make, 25mm nominal bore. (S/2.14.9)

4

2204

551

... More
Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M (S/3.19.1)

3

16467

5489

... More
Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 240 Cm. dia outside & 240 Cm. depth. (S/3.22.3)

2

32200

16100

... More
Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect (S/3.27.1)

2

54644

27322

... More
Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15CM] excluding cost of Pipe & Excavation of trenches etc.: PVC pipe 160 mm dia. (S/3.16.5.2)

45

19125

425

... More
P&F rigid PVC pipe fittings (IS:4985 mark) of approved quality/make including joining the pipe with solvent cement rubber ring and lubricant: Vent Cowel. 110mm dia. (S/3.17.12(ii))

3

168

56

... More
Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.: Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame. (S/3.21.1)

6

6294

1049

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.

-

-

-

... More
(A) Short point .(upto 3 mtr.) (E/1.1.1)

11

3949

359

... More
(B) Medium point (upo 6 mtr.) (E/1.1.2)

15

8670

578

... More
(C) Long point. (upto 10 mtr.) (E/1.1.3)

19

14668

772

... More
Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole, (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second. To ensure the moisture content and electrical conductivity, 25 kg for 2000mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity (less than 0.12 Ohm-meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d), IEEE 837 & IER 1956 with latest amendemnts (c) Connect the rod with copper Strip/ Conductor/ Wire with suitable clamp made from tinned copper and SS 304 Bolt, (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (e) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. (B) 25 mm thick and 3 Mtr. Long. (E/14.4.2)

1

7955

7955

... More
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR- ON Board (E/1.3.1)

12

4284

357

... More
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection, testing, etc. as required. For specification of Wiring accessories refer Chapter E-07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. (E/7.37)

7

4060

580

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
(A) 2 x 2.5 sq. mm. + 1x1.5sqmm. (E/4.1.7)

80

6480

81

... More
(B) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (E/4.1.14)

40

4880

122

... More
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 20mm (E/1.4.1)

25

1000

40

... More
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 1200 mm Sweep BEE 3 Star rated (service value =5.0 to 5.5). (E/15.7.3)

3

6570

2190

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm (E/17.1.1)

13

6396

492

... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover)/Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each. The System efficacy =125 lm/wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety, Power Factor 0.95 driver Efficiency85%, THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C. Driver current750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened, CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/ Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/ LM80) Certificate/ report with liable warranty of product/ accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.

-

-

-

... More
(A) LED Street Light fixture with Minimum lumen output 11225 lm. (E/18.12.6)

4

27060

6765

... More
(B) LED Street Light fixture with Minimum lumen output 2450 lm. (E/18.12.1)

4

10216

2554

... More
Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3. powder painted complete with din rail  making internal DB  terminations with copper lugs,  detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Suitable for Six / Eight module for MCB/ RCCB (E/6.9.2)

2

2198

1099

... More
Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Double Pole Isolator 63A rating. (E/6.2.1.2))

1

453

453

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Single pole MCB (With B/C curve tripping characteristics) 6A to 32A rating (E/6.1.1.2)

4

748

187

... More
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (E/15.10)

3

384

128

... More
Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge, making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 5 step fan regulator 2 Module 360 dgree rotating. (E/7.29.1)

3

1194

398

... More
Providing & Laying P.V.C./XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I/IS : 7098 P-I of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to IS 8130 of purity99.6 %, round/flat strip armouring of cables, Inner/outer sheath confirming to IS:5831 in existing RCC/Hume/Stoneware/PVC pipe/Open duct/cable trench/ Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product/work refer Annexure 'A' attached with this BSR. (A) 4.0 Sq. mm 2 core. (E/11.2.1.1)

200

21800

109

... More
Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work 300 mm sweep(900/1400 RPM). (E-15.12.1)

4

12700

3175

... More
Providing & Fixing of Street light bracket made out from following size of 'B' class, Medium class G.I. Pipe confirming to IS:1239 P-1 (2004) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. 25 mm Dia. (E/18.18.2)

8

4320

540

... More
Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. (B/16.58)

3

5100

1700

... More
Supply installation testing & Commissioning of high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK/ IS:875 Part-1–2015/BSEN10025/and IS:2062) consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7/19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly) foundation bolt, torque limiter, EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on/off, reverse/forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation. (See table P-03 for specs.) OEM Must have Type test certificate for wind tunnel test. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR .12.5 Mtr HM (in 2 section) suitable for 6 No. Luminaries 2 no. rope for lantern carrage & 2 no. rope for winch assembly. (E/18.7.1)

1

225679

225679

... More
SITC of IP-42 and general construction confirming to IEC 61439-1&2. type tested assembly (TTA) wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a) Panel having short circuit withstand capacity of minimum of 50 kA for 1s (Icw rating) at 415 V, 50 HZ AC supply, Rated Impulse withstand voltage (Uimp) of 12kV for withstanding against transient Overvoltages, mechanical impact level of IK10 level and internal arc for 50kA for 0.3 second with aluminum busbar and fully type tested at an Independent Laboratory, Type test certifacte has to be submitted for all rating of LV Switchgear to be used in Panel.(b) All four Horizontal Busbars shall be in same compartment. Certified design of switchboards shall be proven design from OEM (Switchgear Manufacturer). OEM name should be mentioned on top of each column of switchboard. Also, OEM Partnership Certificate shall be furnished by Panel builder. Panel shall be fabricated with a double door arrangement. Front Door shall be fitted with transparent Glass to allow maintenance staff to visually access device status, meter readings, indicating lamp status without opening the door.© Panels and cubicles shall be fabricated with CRCA Sheet Steel of thickness, same as as per OEM Design. Sheet Steel having vibration free structure chemically treated with nine tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity Aluminium busbar extensible type, busbar supports, ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test and Heat run test(type test) shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from Switchgear OEM approved fabricators only. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(E/8.26)

2

19728

9864

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2)/Copper (IEC 60028) bus bar by means of SMC/DMC type insulator with standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade. (E/8.2.2)

1

1301

1301

... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter/Direct- Ammeter/CT oertated ammeter/Frequency meter/KWH meter/Multi Function Meter/ Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Three phase Voltmeter with Inbuilt Selector Switch. (E/8.3.4)

1

1689

1689

... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter/Direct- Ammeter/CT oertated ammeter/Frequency meter/KWH meter/Multi Function Meter/ Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Three phase Ammeter with Inbuilt Selector Switch. (E/8.3.3)

1

1689

1689

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection, with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required. All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR .Ring type tape wound CT, CT Class 1, Ratio upto 150/5, Burden 5 VA. (E/8.4.1.1)

1

614

614

... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. Body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Red/ yellow/Green colour (E/8.8.1)

1

170

170

... More
Providing & Laying P.V.C./XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I/IS :7098 P-I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity 99.7 %, round/flat strip armouring, Inner/outer sheath confirming to IS:5831 in existing RCC/Hume/Stoneware/PVC pipe/Open duct/Cable trench/Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product/work refer Annexure 'A' attached with this BSR.

-

-

-

... More
(A) 35 Sq mm 3 Core (E/11.4.8.3)

50

82550

1651

... More
(B) 16 Sq.mm 4 core (E/11.4.6.4)

70

71470

1021

... More
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. 30mm x 5 mm copper strip. (E/14.5.4)

4

7760

1940

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product/work refer Annexure 'A' attached with this BSR Four pole MCB (With B/C curve tripping Characteristics) 6A to 32A rating. (E/6.1.4.2)

3

3669

1223

... More
SITC of 3/4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/ 415 V, 50 Hz; O/L & S/C settings, conforming to IS/IEC 60947 P -2: 2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR, shunt trip, earth fault trip, door interlock, pad lock & rotary handle, including making connections etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product/work refer Annexure 'A' attached with this BSR 4 pole MCCB With Thermal Magnetic release : (A) Up to 100 Amp, 25 kA, adjustable O/L & adjustable S/C setting, (E/9.3.3.2)

1

7112

7112

... More
(B) 160 Amp, 25 kA, adjustable O/L & adjustable S/C setting, (E/9.3.3.4)

1

11835

11835

... More
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 lm/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety. Power Factor0.95, THD(I) 10%, driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/ Embossing/Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/report with liable warranty of product/ accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. High Power LED Flood Light Minimum lumen output 22400 lm. (E/18.11.8)

6

79800

13300

... More
P&F steel gate grating and grills made of angles, tees, square bars, flats or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. (B/9.8)

2380

228480

96

... More
Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering: 1:2:4 M15 grade nominal mix (1cement: 2coarse sand: 4graded stone aggregate 20mm nominal size). (B/3.2.2)

7

35784

5112

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. (B/4.10.3)

18

6750

375

... More
Add extra for each galvanised barbed wire line. (B/9.33+9.35+9.35.1)

1170

15444

13.2

... More
Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size Welded mesh 25mmx25mmX2.1mm. (B/9.38.3)

23

17250

750



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.