Jaipur Metro Rail Corporation Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 51,551Document Cost
₹ 1,180Tender Fee
₹ 590
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_JMRC_377629_1Bid Award Id
ViewTender No
JMRC/OS/EL/2023-24/NIB/032Tender Authority
Jaipur Metro Rail Corporation Limited ViewPurchaser Address
-Website
http://http://transport.rajasthan.gov.in/jmrc
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
32mm
50
-
-
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FRLS PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked (IS:9537 P-II) rigid steel conduit & it's accessories, round tiles, Hot Dipped Galvanized Modular Box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 A Modular switch, Modular plate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required.
-
-
-
Short point (up to 3 mtr.)
40
-
-
Medium point (up to 6 mtr.)
60
-
-
Long point (up to 10 mtr.)
50
-
-
Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FRLS PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & it's accessories, Hot Dipped Galvanized M.S Modular box with earth terminal, screwless cage connectors for neutral looping in switch board, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required.
-
-
-
On board
40
-
-
Short point (up to 3 mtr.)
40
-
-
Medium point (up to 6 mtr.)
40
-
-
Long point (up to 10 mtr.)
25
-
-
Supplying and drawing FRLS PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
-
-
-
1 x 1.5 sq.mm
100
-
-
2 x 1.5 sq.mm
200
-
-
3 x 1.5 sq.mm
100
-
-
4 x 1.5 sq.mm
50
-
-
1x 2.5 sq.mm
50
-
-
2 x 2.5 sq.mm
50
-
-
2 x 2.5 sq.mm. + 1 x 1.5 sq.mm
500
-
-
3 x 2.5 sq.mm
100
-
-
4 x 2.5 sq.mm
200
-
-
6 x 2.5 sq.mm
20
-
-
2 x 4.0 sq.mm
50
-
-
3 x 4.0 sq.mm
200
-
-
4 x 4.0 sq.mm
50
-
-
6 x 4.0 sq.mm
50
-
-
2 x 4.0 sq.mm. + 1 x 2.5 sq.mm
50
-
-
1 x 6.0 sq.mm
50
-
-
2 x 6.0 sq.mm
50
-
-
3 x 6.0 sq.mm
50
-
-
4 x 6.0 sq.mm
20
-
-
2 x 6.0 sq.mm. + 1 x 2.5 sq.mm
50
-
-
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required
-
-
-
Double pole MCB
-
-
-
6 A to 32 A rating
30
-
-
40 A 63 A rating
10
-
-
Four pole MCB
-
-
-
6 A to 32 A rating
20
-
-
40 A 63 A rating
10
-
-
P&F 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections with lugs, testing etc. as required.
-
-
-
Two pole 30 mA sensitivity
-
-
-
25 A rating
10
-
-
40 A rating
10
-
-
Four pole 30 mA sensitivity
-
-
-
25 A rating
4
-
-
40 A rating
4
-
-
63 A rating
4
-
-
P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self-extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc. as reqd.
-
-
-
Panel mounted socket
-
-
-
16 A 3 pin
10
-
-
Plug top
-
-
-
16 A 3 pin
10
-
-
P&F recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing, phophatised, powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs, testing etc. as required.
-
-
-
Double door
-
-
-
6 Way
4
-
-
8 Way
4
-
-
P&F recessed mounting heavy duty sheet steel End Box for distribution board duly phophatised powder coated complete as required.
-
-
-
For TPN 4 way DB
4
-
-
For TPN 6 way DB
4
-
-
P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required.
-
-
-
6 A one way switch
40
-
-
16 A one way switch
40
-
-
6 A 3 pin shuttered socket
40
-
-
16 A 6 pin shuttered socket
20
-
-
P & F following size mounting grid plates with cover plates.
-
-
-
1/2 Module
10
-
-
3 Module
10
-
-
4 Module
10
-
-
P & F following size hot dip galvanized M.S. box of 20 SWG with earthing terminal in recess/ surface suitable for modular accessories as required.
-
-
-
1-2 Module
10
-
-
3 Module
10
-
-
4 Module
15
-
-
P & F of Multiple socket with surge and spikes protection cartridge and minimum four nos. universal 6 A sockets, one 6 A switch and plug top including making connection etc. as required.
20
-
-
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.
-
-
-
Red/Yellow/Green color
20
-
-
Blue color
20
-
-
P & F of Multifunction meter with LCD/ LED display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect.
2
-
-
Providing & Fixing of IP51director CT operated, 1x240/3x240volts, 50Hz static watt-hour meter (kwh) as per PWD specification for electrical Works, ISI marked (IS:13010-2002) having resolution0.1/0.01kwh,accuracy class1 as per IS:13779, LED indicators for tamperoperation (Reverse&/orearthconnection), pulsating LED indicator for meterology, LCD Display, cover plate for body and terminal sealing,push button for all standard parameters, including making connection, testing etc. as required.
-
-
-
up to 40 ampere single phase meter
5
-
-
up to 60 ampere three phase meter
5
-
-
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sanding class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
Note 1: If cable laid in existing RCC/ Hume/ Stoneware pipe then deduct @ 20/- per meter.
Note 2: If cable laid on existing cable trays with cable ties then deduct @ 20/- per meter.
Note 3: If cable laid on surface by means of screws, rag bolts, MSU clamps, as per approved spacing then deduct @ 12/- per meter.
Note 4: If cable laid in open duct then deduct @ 20/- per meter.
Note 5: If trench excavation in C.C. flooring/Tar Road then add @ 50/- per meter.
Note 6: if cable laid through vernier machine then add @ 350/- per meter.
-
-
-
10.0 Sq.mm Armoured Cable
-
-
-
3 core
100
-
-
4 core
100
-
-
10.0 Sq.mm UnArmoured Cable
-
-
-
3 core
50
-
-
4 core
50
-
-
16.0 Sq.mm Armoured Cable
-
-
-
3 core
100
-
-
4 core
200
-
-
35.0 Sq.mm Armoured Cable
-
-
-
3.5 core
100
-
-
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable (Armoured) of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
Note 1: If cable laid in exsiting RCC/Hume/Stoneware pipe then deduct @ 20/- per meter.
Note 2: If cable laid on exsiting cable trays with cable ties then deduct @ 20/- per meter.
Note 3: If cable laid on surface by means of screws, rag bolts, MSU clamps, as per approved spacing then deduct @ 12/- per meter.
Note 4: If cable laid in open duct then deduct @ 20/- per meter.
Note 5: If trench excavation in C.C. flooring/Tar Road then add @ 50/- per meter.
Note 6: if cable laid through vernier machine then add @ 350/- per meter.
-
-
-
1.5 Sq.mm
-
-
-
3 core
150
-
-
4 core
100
-
-
2.5 Sq.mm
-
-
-
3 core
100
-
-
4 core
100
-
-
4.0 Sq.mm
-
-
-
3 core
100
-
-
4 core
100
-
-
6.0 Sq.mm
-
-
-
3 core
100
-
-
4 core
100
-
-
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.
-
-
-
3 x 10.0 sq.mm
20
-
-
3 x 16.0 sq.mm
20
-
-
4 x 10.0 sq.mm
20
-
-
4 x 16.0 sq.mm
10
-
-
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.
-
-
-
3 x 2.5 sq.mm
5
-
-
3 x 4.0 sq.mm
5
-
-
3 x 6.0 sq.mm
5
-
-
4 x 2.5 sq.mm
5
-
-
4 x 4.0 sq.mm
5
-
-
4 x 6.0 sq.mm
5
-
-
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
-
-
-
8 SWG copper Wire
50
-
-
8 SWG G.I. ( Hot Dipped ) Wire
50
-
-
P & F of capacitor start, Metal Body, Metal blade high air delivery with three speed, wall mounting fan of following sweep with the help of anchor bolts including making conncetion testing as required.
-
-
-
400mm sweep (Oscillating type)
50
-
-
P & F of capacitor start, three speed, oscillating type pedestal fan with adjustable height, of following size with cord and plug top as required.
-
-
-
400 mm sweep
10
-
-
Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect
-
-
-
160 mm X 225 mm X 100 mm
10
-
-
P&F of thermoplastic/ PVC cable junction boxes of following sizes including clamps for holding the box, cost of DIN rail for MCB mounting, connectors for cables terminals, threaded cable glands made of polyamide material etc. complete in all respect.
-
-
-
175mm X 150mm X100mm
10
-
-
Rewinding of Wall mounted Bracket fan motor including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required.
-
-
-
400 mm sweep, 50W, 1300 rpm (Oscillating type )
50
-
-
Providing and Replacement of bush, shaft and bearing for Bracket fan as required.
50
-
-
Providing and Replacement of capacitor of Bracket fan as required.
50
-
-
Rewinding of Heavy duty Exhaust fan motor, 450mm sweep including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required.
-
-
-
Exhaust wall mounted fan, 300-350mm sweep
15
-
-
Exhaust wall mounted fan, 400-450mm sweep
15
-
-
Providing and Replacement of Bush of Exhaust fan as required.
30
-
-
P & F of double ball bearing capacitor start, aluminium body & blade ceiling fan with downrod up to 30cm with 3x1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.as required.
-
-
-
1200 mm sweep
50
-
-
1400 mm sweep
50
-
-
P&F of M.S. J-hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required.
10
-
-
Repairing and fixing of electric water geyser (2000 watts/15 ltr.) including valve, thermostat, element, connector etc. as required in JMRC Flats.
15
-
-
P&F of 5 star rated vertical storage water heater with outer casing made of M.S. sheet finished with anti-corrosive powder coating, inner tank made of pure electrolytic copper/stainless steel/SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceramic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, pressure release valve, fusible plug etc. as required held in position with 4no. rack bolts, duly wired with 3 core 2.5/4.0 sq.mm PVC insulated & sheathed copper conductor and 16A/25A three pin plug top, including making inlet, outlet heavy gauge C.P./ Flexible
5
-
-
Supply and fixing of LED Street light fixture 90 W Lumen Efficacy (Lm/W)≥100 with removing existing faulty old conventional lights (200 watts) including Making connection as required. Make-Bajaj, Philips, CG, HPL or similar superior.
10
-
-
P&F of ventilating fans, capacitor start, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.
PWD BSR CODE :E171100
200mm sweep
PWD BSR CODE: E171102
20
-
-
Exhaust Ventilation Inline Duct fan
-
-
-
Rewinding of Fan Motor of Ventilation Inline duct fan Caryaire Direct Drive Cabinet Fans Make : NICOTRA/Gebhardt
Model: CDIF-09DS (CDIF DS Series)
Max Watt : 370 Watt /1380 RPM
8
-
-
Reparing and overhauling of the fan motor by replacement of warm out bush/bearing/shaft of Caryaire Direct Drive Cabinet Fans Make : NICOTRA/Gebhardt
Model: CDIF-09DS (CDIF DS Series)
Max Watt :370 Watt /1380 RPM
8
-
-
Providing Arrangement for testing, dismantling and refixing after repairing of the existing faulty inline fans
8
-
-
Providing and making arrangement of Hydra/Crane with trolley for maintenance and replacement of Pole lights, Parking High Mast Light and other miscellaneous electrical work ( up to 30 Mtr height )
64
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements