Indira Gandhi Nahar Project Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Indira Gandhi Nahar Project - IGNP Tender

Services
Electrical and Electronics
Eprocure
Opening Date22 Nov 2024
Closing Soon3 Dec 2024
Tender Amount₹ 35,83,580 
Notes
Download

Costs

  • EMD

    ₹ 71,672
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 500

Summary

Sitc Of 50 Kva And 125 Kva Dg Set With Amf

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SITC of 50 KVA and 125 KVA DG Set with AMF Panel with Required Earthings, Foundation and Cables etc. for Chief Office main building and Adm. Office Building IGNP Bikaner (Item No-1)
SITC of 50 KVA and 125 KVA DG Set with AMF Panel with Required Earthings, Foundation and Cables etc. for Chief Office main building and Adm. Office Building IGNP Bikaner (Item No-1)
SITC of 50 KVA and 125 KVA DG Set with AMF Panel with Required Earthings, Foundation and Cables etc. for Chief Office main building and Adm. Office Building IGNP Bikaner (Item No-1)
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc in layer not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering including lead up to 50m and all lift.

4.33

64

277.12

... More
Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm;

11.81

5093

60148.33

... More
Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 7.14.1 Add extra if well burnt clay bricks (size 230x110x70 mm) class designation 100 as per specifications are to be used Over Item No. 10

17.43

6257

109065.78

... More
Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 7.14.1 Add extra if well burnt clay bricks (size 230x110x70 mm) class designation 100 as per specifications are to be used Over Item No. 10 7.13 Add extra for superstructure brick masonry on item no 10

27.65

6469

178877.8

... More
Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and removing

74.64

225

16794

... More
Providing and Laying in position of Cement concrete Design mix M-20 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; (For mix design Cement content considered 400 kg/ cum of concrete) 20 mm 9.13.4 Add extra over item No. 1 to 7 Add Extra for RCC work for sluice well, intake, pump house, Arch, Ogee

14.44

6513

94047.72

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) (3) Thermo-mechanically Treated bars (Conforming of relevent IS code

1535.72

77

118250.06

... More
Providing and Fixing unplasticised (UPVC) SWR pipes type B FOR SCILAND waste discharge system (is:13592:1992 mark) of approved quailty /make (i) single socketed pipes Tpye B 110 mm dia

17

336

5712

... More
Plaster in cement sand mortar 1:5 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness (b) 12mm

198.66

230

45691.8

... More
Cement concrete flooring grade 1:2:4 (1 cement, 2 course sand, 4graded stone aggregate) rounded off edge etc. but excluding the cost of nosing etc. complete, 40 mm thick with 20 mm nominal size aggregate.

30.89

277

8556.53

... More
Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required.

3.24

3090

10011.6

... More
Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size. Welded mesh 25mmx25mmx2.10mm

3.42

750

2565

... More
Providing and fixing T-iron frames for doors window and ventilators of mild steel tee-sections, joints mitered and welded with 15x3 mm lugs 10 cm long embedded in cement concrete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement :3 course sand : 6 graded stone aggregate 20mm nominal size) or with wooden plug and screw or rawl plugs and screws of with fixing clips or with bolts and nuts as require including fixing of necessary but hinges and screw and applying a priming coat of approved steel primer.

7.48

83

620.84

... More
Providing and fixing MS sheet 1mm thick single doors shutter in angle iron frame 35 x35 x5mm suitably diagonally braced with 25 x3mm flat iron above and below lock rail of size 50 x5mm beading extra including all fitting, as per direction of Engineer Incharge but excluding cost of Chowkhats : including two coats of anti corrosive red oxide primer paint MS sheet 22 S.W.G

2.15

2869

6168.35

... More
Distempering with 1st quality Acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete including all scaffolding as per manufacturers specification. Two or more coats on new work including preparation of base with primer, putty, lippy etc. complete in all respect.

227.35

43

9776.05

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(1) two or more coats on new work

10.78

69

743.82

... More
Finishing walls with Acrylic smooth exterior paint of required shade including all scaffolding. New work(Two or more coat applied @ 1.67 Ltr./10 sqm over and including base coat of water proofing cement paint applied@2.20 kg/10sqm).

115.55

86

9937.3

... More
Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto, (d) 20mm

4.59

5648

25924.32

... More
Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment).

14.4

1442

20764.8

... More
Providing and amp; Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED and amp; should be SMD type . The System level Luminaire efficacy and gt;=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted and amp; has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @ and gt;=300 V AC and Auto resetting Safety ,Input Frequency 50Hzñ3% Power Factor and gt;0.95 driver Efficiency and gt;85% ,THD(I) and lt;10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current and lt;1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index and gt;70 and CCT 5700K +355K. Surge protection shall be min ò 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR LED Street Light fixture 100 Watt

2

8501

17002

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit and amp; its ISI marked (IS:14768 P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets and amp; Electrical/ Wiring accessories refer Chapter E - 04, E - 05 and amp; E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR i- shortpoint (upto 3 Mtr)

2

853

1706

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit and amp; its ISI marked (IS:14768 P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets and amp; Electrical/ Wiring accessories refer Chapter E - 04, E - 05 and amp; E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR ii- medium point ( Upto 6 Mtr)

2

476

952

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit and amp; its ISI marked (IS:14768 P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets and amp; Electrical/ Wiring accessories refer Chapter E - 04, E - 05 and amp; E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR iii- long point (Upto 10 mtr)

2

1185

2370

... More
Wiring of 3/5 pin 6 amp. Litght plug point as per PWD specification for electrical work with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conduct 1.1 KV grade( IS:694) in and 1.5 sq mm nominal size FR PVC insulated unsheated flexible copper earth conductor 1.1 KV grade (IS: 694) in recessed ISI marked (IS:9537P-II) rigid steel conduit & its all accessories, required size 18 SWG, G.I. box with earth terminal,6A switch,3/5 pin 6A socket,3.0 mm thick ISI marked phenolic sheet pvc bushes, check nuts, Al. alloy/ cadmium plated iron screws 20mm cup washers etc. All as per pre approved by Engineer in charge, making connections, testing etc. complete as per required. For specification of copper conductor, phenolic Laminated sheets & Electrical/ wiring accessories refer Chapter E-05& E-07. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. On board

3

87

261

... More
Providing & Fixing of 240/415 V MCB with positive isolation of braking capaciy not less then 10 KA ( B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical works with ISI marked IS 8828(1996)/ conforming to IEC 60898-1 2002,IEC 60947-2 low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimm phase termination capacity of 35sq.mm, conductorline load reversibility, label holding acility, IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making cannections testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab test report before execution & all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR ( Double pole MCB 40 A rating) 40 A rating Group II

3

620

1860

... More
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR

1

128

128

... More
Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output pf 0.95, CRI 70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till ife ends, CCT 3000°K / 4000'K 5700K /6000"K/6500'K (As per ANSI Bin) maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( TC). Manufactures word mark/name Engraved/embossing/screen painting on housing OEM must have its own in house NABL lab setup for all testing facilites for LED fixtures (LM 79/LM80 ) certificate/report from OEM shall be submitted. All as per pre approved by engineer in charge for additional technical parameters of product/ work, refer Annexure "A" attached with this BSR.15 Watt

6

117

702

... More
P & F of ISI marked (IS:1258) 6amp batten/angle lamp holder as per PWD specifications for electrical works made out from industrial grade polycarbonate or fire resistant making connection testing etc. As required all as per pre approved by Engineer in Charge. for additional technical parameters of products/work refer annexure "A" atteached with this BSR

6

19

114

... More
Providing & Fixing of non modular socket size flush type 120 watt rotary minimum 5 step fan regulator as per PWD specification for electrical Works, ISI marked (IS:11037) made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required. all as per pre approved by Engineer in Charge. for additional technical parameters of products/work refer annexure "A" atteached with this BSR

1

135

135

... More
Providing & Fixing of ISO Certified company made BEE star rated copper wounded double ball bearing capacitor start, aluminium body & metallic blade ceiling fan as per PWD specification for electrical work, conforming to IS :374-2019&IS:1885-P-V1981. with down rod up to 30 cm with secondary support safaty cable(steel wire),cotter pin with 3x1.5 sq.mm pvc insuleted flixible copper conductor making connection testing etc.as required Appropriate OEM test certificate shall be submitted by chsrge. Foe refer Annexure"A"attached with this BSR( 1200 MM Sweep bee 2 star rated(service value=5.0to5.5)

1

1572

1572

... More
Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 450 mm sweep(900/1400 RPM)

2

5883

11766

... More
SITC of DG set 125kva & 50 kva

-

-

-

... More
Supply of Glavanised iron Eathing strip of size 50 x 6 mm

20

250

5000

... More
150700 S and Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.150710 32mm x 6mm copper strip150710.2 Complete Rate

20

1174

23480

... More
SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & I A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP (up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or above required ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber), up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . B) AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade. D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA. F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. G) Servicing Contract of DG Set from OEM's Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. I) DG set will be offered for Inspection and Testing at Manufacturer's Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

703132

703132

... More
SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & I A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP (up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or above required ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber), up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . B) AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade. D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA. F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. G) Servicing Contract of DG Set from OEM's Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. I) DG set will be offered for Inspection and Testing at Manufacturer's Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

1072760

1072760

... More
281500 SITC of Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start and Stop commands, control Relays , selector switches for Ammeter and Voltmeter, Ammeter and Voltmeter , Control and Power Contactors, Timers, Electronic Hooter ,Visual and Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:281520 Electro-Mechanical Relay Based281521 25 to 63.5 KVA281521.2 Group - 1

1

56250

56250

... More
281500 SITC of Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start and Stop commands, control Relays , selector switches for Ammeter and Voltmeter, Ammeter and Voltmeter , Control and Power Contactors, Timers, Electronic Hooter ,Visual and Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:281520 Electro-Mechanical Relay Based281522 80 to 180 KVA281522.2 Group - 1

1

101250

101250

... More
Supply of P.V.C. / XLPE insulated and P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity greater than 99.6 percent, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 3.5CX95 Sq.mm

100

1416

141600

... More
Supply of P.V.C. / XLPE insulated and P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity greater than 99.6 percent, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 3.5CX185 Sq.mm

100

2583

258300

... More
Providing and fixing of 2500 mm length Earthing pipe electrode with earthing chemical and complete with all accessories

8

5680

45440

... More
Elec. Shock proof rubber matting 2000x1000x12 mm

8

2620

20960

... More
CO2 type fire extinguishers capacity 4.5 kg ISI mark

4

6600

26400

... More
Supply and fixing of 1.6 mm thick Mild Steel Danger plates on the existing pole/ structure as per IS :2551-1982 and vitreous enamelled white, with figures and the conventional skull and cross-bones inletters, signal red colour on the front side. The rear side of the plate shall also be enamelled complete in all respectas as required For display at medium voltage (upto 650 V) installations 200 x 150 mm

4

1210

4840

... More
O & M work of DG

-

-

-

... More
Mason/ Painter/ Carpenter/ Electrician /Black smith / Plumber Grade II (2 elctrician per day for 365 days = 730 days) Grade II

730

490

357700



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.