Indira Gandhi Nahar Project Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Indira Gandhi Nahar Project - IGNP Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date2 Jan 2025
Closing Soon13 Jan 2025
Tender Amount₹ 9,61,547 
Notes
Download

Costs

  • EMD

    ₹ 19,231
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 500

Summary

Servicing And Overhauling Of 3.3 Kv, 270 Kw Motor Sr No 2054417 And 150 Kw Motor Sr No 136716 At Ps Ii Malkisar With Repairing Of Stator Lead Of 670 Kw Motor At Ps I Rajiasar Of Ksl Canal For The Year 2024-25

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Transportation charges for 3.3 KV HT Motor repair / servicing /rewinding from site to workshop and from workshop to site For 3.3 kV 150 KW / 270 KW/ 670 KW motor (PS-I nad PS II Malkisar)

2

85000

170000

... More
Providing and Fixing of Stator lead per lead (approx 2.5 Meter. length) of 3.3 KV HT induction motor 150 KW-300 Kw. For 150 KW nad 270 KW motor ( PS-II Malkisar)

3

13500

40500

... More
Providing and Fixing of BTD of 3.3 KV HT induction motor For 3.3 kv 270 KW motor (PS II Malkisar)

1

6700

6700

... More
Providing and Fixing of RTD of 3.3 KV HT induction motor For 3.3 kv 270 KW motor (PS II Malkisar)

1

14500

14500

... More
Providing and Fixing of Insulator/Bushing/Lugs of 3.3 KV HT induction motor For 3.3 kv 270 KW motor (PS II Malkisar)

1

20700

20700

... More
Providing and Fixing of grease pipe for DE side of 3.3 KV HT induction motor For 3.3 kv 150 KW/270 KW motor Sr No 2044234/01 (PS II Malkisar)

2

1120

2240

... More
Providing and Fixing of grease pipe for NDE side of 3.3 KV HT induction motor For 3.3 kV 150 KW/ 270 KW motor Sr No 2044234/01 (PS II Malkisar)

2

1120

2240

... More
Bearing7324 For 3.3 kv 150 KW motor (PS II Malkisar

1

109827

109827

... More
Bearing 7320B For 3.3 kv 270 KW motor (PS II Malkisar)

1

50429

50429

... More
Bearing NU 226 MC3 For 3.3 kv 270 KW motor (PS II Malkisar)

1

25736

25736

... More
Bearing NU 324 MC3 For 3.3 kV 150 KW motor (PS II Malkisar)

1

37611

37611

... More
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Autoresetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. Driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI >70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability /authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR - High Power LED Flood Light Minimum lumen output 25000 lm ( PS I = 4 Nos and PS II= 4 Nos)

8

15583

124664

... More
Repairing of stator lead and bushings of 670 kw motor Sr No 2054415 at PS I rajiasar

-

-

-

... More
Providing and Fixing of Stator lead per lead (approx 2.5 Meter. length) of 3.3 KV HT induction motor 301KW-700KW 670 kw motor Sr No-2054415 (PS-I Rajiasar)

3

16500

49500

... More
Providing and Fixing of Insulator/Bushing/Lugs of 3.3 KV HT induction motor For 3.3 kv 670 KW motor (PS I Rajiasar)

1

20700

20700

... More
Providing and Fixing of BTD of 3.3 KV HT induction motor For 3.3 kv 670 KW motor (PS I Rajiasar)

1

6700

6700

... More
Providing and Fixing of RTD of 3.3 KV HT induction motor For 3.3 kv 670 KW motor (PS I Rajiasar)

1

14500

14500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.