Medical Health And Family Welfare Department Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
Refer DocumentsDocument Cost
₹ 2,000Tender Fee
₹ 1,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MEDIC_223102_6Bid Award Id
ViewTender No
NIT 14/2021-22 EE M and H Dn. I Jaipur/Tender Authority
Medical Health And Family Welfare Department ViewPurchaser Address
-Website
http://http://www.rajswasthya.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
CIRCULAR, DLP Orders, Unbalance Order, Provisions of RTPP Act-2012 and P P Rules-2013
BOQ Items
... More
For 15 MM OD pipe
84
-
1103
... More
For 22 MM OD pipe
18
-
1357
... More
For 28 MM OD pipe
12
-
1867
... More
For 42 MM OD pipe
4
-
3139
... More
SITC of Gas outlet points (AR-4), (AR-7) and vacumm (8.7 psig) for dispensing medical gases (oxygen/air/vaccum) at point of use confirming to BSEN ISO 9170-1: 2008. The Gas outlet are quick connect for different gas source and should accept only respective adapters as required.
698
-
2054
... More
SITC of BPC (back pressure compensated) flow meter with humidifer made of nickel plated body double jacketed with flow gradations marked on it. Desired flow will be setteled through roatary knob. Flow range should be between 0 to 15 Ipm & work should be executed as per direction of engineer n charge.
366
-
1506
... More
SITC of suction unit (suction controller and collection jar) with posibility to configure required capacity capacity collection jar and should meets the requirements as per BSEN ISO 10079-3:2009 the unit must designed to operate with the vacucum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for operating temperature - 18'C to 50'C with ON/OFF facility. The collection jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121'C for 20 minutes for reuse and provided with auto stop to avoid over spill and contamination of the suction source when the jar collection reached optimized level, the complete unit supplied with filter to protect the source and pipe line from bacterial contamination.
-
-
-
... More
600 ml Capacity collection Jar
274
-
2438
... More
SITC of Valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for sxygen and vaccum line and should comply with ENISO5211:2001 complete with ball type valves and gauses as required for oxygen compressed air and vaccum line (three gas)
-
-
-
... More
For Three Gas
30
-
11778
... More
For Four Gas
6
-
14380
... More
SITC of microprocessor based auto alarm system (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS Zoning it should monitors the current status of oxygen/ compressed air pressure in distrubuton pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN ISO:7396-1:2007
-
-
-
... More
For Two Gas Services
24
-
11709
... More
For Three Gas Services
12
-
15612
... More
For Four Gas Services
6
-
19516
... More
SITC of Bed Head Panel of 1200-1500 MM long made out from high strength extruded aluminum with powder coating with 4 nos 6/16 Amp switch socket and provision for four Nos gas outlet point work should be executed as per directions of engineer in charge and of CE certified makes.
16
-
15818
... More
Providing and Fixing of Rail clamp for mounting ward vaccum unit on bed head panel complete as required.
16
-
450
... More
SITC of automatic gas control panel for oxygen/nitrous oxide control panel cover made for M.S duly powder coated. Compact and fully automatic manifold control system for oxygen services easy to maintain and use Designed with both safety and continuity of flow supply at a constant pressure via two banks of bottled gas cylinders with following status monitoring A- Bank in use (Green Indication) B- Empty bank (Red Indication) Control Panel should have built in LED display to indicate Normal, High & Low line pressure. It should have facility to test all above indicators working perfectly. The control Panel should include pressure gauge to indicate the gas pressure of each header and pipe line distribution pressure. Capable to provide a distribution flow rate in excess of 1200 LPM. The control panel should incorporate manual bypass system in case of failure of shifting mechanism. It should be of CE certified product.
6
-
127609
... More
SITC of Oxygen/Nitrous Oxide Manifold System (8,8)with tal pipes NRV-manifold system comprise of bank of 8+8 cylinders (Bulk cylinder of D type) capacity manifold high pressure copper pipe of size 1/2"ID x14 swg (approx 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 16 no's non return valves & 16 no's high pressure flexible tail pipe is made of copper pipe of 1/3"x16 swg (approx. 1.6256 mm) the manifold is hydraulically tested at 225 kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag make CE Approved/CE. Note: Providing of Cylinders is in the scope of Hospital / End Client.
6
-
52690
... More
SITC of Oxygen/Nitruous Oxide Manifold System (4+4) with tail pipes NRV- manifold system comprise of bank of 4+4 cylinders (Blk cylinder of D type) capacity manifold high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 8 no's non return valves & 8 no's high pressure flexible tail pipe is made of copper pipe of 1/3"x16 swg (approx. 1.6256mm ) the manifold is hydraulically tested at 225 kg/cm2 pressure it is also degreased and is to be offerred duly wrapped in a polythene bag make CE Approved/CE certified. Note: Providing of Cylinders is in the scope of Hospital/Eng Client.
6
-
26345
... More
SITC of Oxygen/Nitrous Oxide emergency system Emergency manifold system comprise of bank of 1+1 cylinders (Bulk cylinder of D type) capacity manifold high pressure copper pipe of size 1/2"IDx14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 2 no's non return valves & 2 no's high pressure flexible tail pipe is made of copper pipe of 1/3"x16 swg (approx. 1.6256 mm) the manifold is hydrauically tested at 225 kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag. One High pressure imported and approved make double gauge regulator with manual pressure setting option and showing cylinder and line pressure make CE approved/CE certified. Note: Providing of cylinders is in the scope of Hospital / End Client.
6
-
6586
... More
SITC of Dessicant Air Dryer Output Capacity - 60 cfm with UL certified Microprocessor Controller with dewpoint based changeover option, Pre-filter rating 0.3 microns, shuttle valve for low pressure drop, All Aluminium resist oxidation & scale fromation dewpoint better than - 4º C including fixing on wall with required T&P making connections etc complete in all respect.
6
-
107731
... More
SITC of compressed air syste should consist on 1 nos. air compressors with electric motors electrical switch gear and automatic control system of following. Specification: A) Air Compressor 1 (One) Nos: Type Non-lubricated /Oil-free capacity 57 cfm at 8.5 kg/cm2 cooling air cooled B) Drive electric motor 2 (Two) Nos. Capacity 15 HP Speed 1440 rpm drive belt drive Electricity supply 440 volt, 50 hz 3 Phase. C) Starter Star/Delta Control & Switchgear with overload protection including making PCC foundation and fixing withbolts anti vibration pad and making connections complete as required.
6
-
395015
... More
SITC of Vacuum pump of single stage capacity 4235 lpm/149 cfm (piston displacement) The pump should be suited for maximum working pressure of 29 inch mercury (730 mm mercury) The pump should be fitted with MS channel frame complete having vibration isolators with 1 Nos. silencers at vacuum pump discharge end. The pump should be air cooled 1 sets of isolation valve on return valve and filter should be provided with pumps. Drive Assembly The electrical drive for vacuum pump should consist of suitable TEFC induction motor operating at 1440 RPM and connected through a V-belt. The motor should be suited for 415 V+10% 50 HZ.3 Phase AC supply capacity : 10 HP of a reputed make vacuum switch vacuum switch of 0-760 mm range should be provided it should have both NO/NC contracts and suitable for 230 V 50 Hz . AC supply. The vacuum switch should be housed in weather proof casing with 3/8"BSP gas service connection at the bottom of the assembly. Vacuum Filter 1 Nos vacuum filters with drain valve. This filter should be non-ferrous and in line. including making PCC foundaton and fixing with bolts, anti vibration pad and making connections complete as required.
6
-
484072
... More
SITC of compressed air filtration system: one set of 3- stage filter the filters should be made of die cast aluminums housing with epoxy power paint on the outside and anodized surface treatment inside to prevent corrosion and ensure extra long life. The filters should have maximum contaminant removal efficiency with minimum pressure drop. Total 3-stage of filters should be used as mentioned below:- Stage1:- coalescing filters for general purpose protection removind liquid water and oil aerosol to 0.1 mg/cum (0.1 pm) and and particles down to 5 micro. Stage :- 2 particular filter for dust protection removing particles down to 1 micron. Stage:- 3 high efficiency coalescing filters, removing liquid water and oil aerosol to 0.01 mg / cum (0.01 pip) and particles down to 0.01 micron.
6
-
56020
... More
SITC of hot dipped galvanized ( inside and outside) Air receiver tank (as per IS: 7938-1976 and upto date amendment ) for compressed air system to dampen out pulsatin and condense and trap the moisture in the compressed air and also to let oil and other impurities settle down before air passes into the piping with safety valve Drain Valve Pressure gauge and fusible plugs of 1000 litres capacity complete as required including making PCC foundation and fixing with bolts and making connections complete as required.
12
-
56020
... More
P&F recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCCB and SP / TP MCB as outgoing , phophatised ,powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet & conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.
-
-
-
... More
Double door with Provision of Incomer MCCB 100 / 125 A Rating
-
-
-
... More
6 Way
6
-
5130
... More
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.
-
-
-
... More
Triple pole MCB
-
-
-
... More
40 A 63 A rating
12
-
1034
... More
Single pole MCB 6A to 32A
18
-
151
... More
SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required.
-
-
-
... More
With Thermal Magnetic release
-
-
-
... More
up to 100 Amp , 10 kA, fixed O/L & S/C setting
6
-
1732
... More
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.
-
-
-
... More
10.0 Sq.mm ,4 core (Un Armoured)
150
-
129
... More
25 sq mm 3.5 core Ar
200
-
208
... More
Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes.
-
-
-
... More
With Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating
-
-
-
... More
GI pipe 2000 mm long, 50 / 25mm, Terminal 12 mm GI Strip
12
-
6150
... More
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
-
-
-
... More
25mm x 3mm G.I. ( Hot Dipped ) Strip
180
-
58
... More
S&F following sizes of ISI marked ( IS:14927 P - II ) PVC casing capping along with accessories like coupler, inner, outer, elbow, square box, tee etc. on surface with screws, expansion fasteners as required.
-
-
-
... More
20 mm x 12 mm
160
-
24
... More
P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required.
-
-
-
... More
2.5 Sq.mm 3 core flat / Round
160
-
90
... More
P & F ISI marked 16 amp bakelite unbreakable 3 pin plug top including making connection testing etc. as required.
34
-
45
Evaluation Notes How It Works ?