Food Corporation Of India Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Food Corporation Of India - FCI Tender
Electrical and Electronics
Eprocure
Opening Date22 Oct 2024
Closing Date6 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 80,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_FCI_832013_1Bid Award Id
ViewTender No
ROJ/ELECT/12/2024-25Tender Authority
Food Corporation Of India ViewPurchaser Address
-Website
http://http://fci.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying, installation, testing and commissioning of automatic mains failure control suitable for 30kVA including By pass panel of 16SWG CRCA sheet floor mounted type, weather proof, corrosion resistance, water proof, Powder coated, powder painted, 7 tank process with suitable rating of 02 nos. FP MCCB, 02 nos. FP Contactors, aluminium bus bar/ 4 way terminal connector for Grid, DG output and common output as approved by Engineer in Charge, suitable for required capacity of silent type DG site complete with relays, timers, set of CTs for metering & protection and energy analyser indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF Panel to diesel Engine and else where if required all complete and inter locking including all the required installations as mentioned in detailed specification sheet for DG set etc. as required. The AMF Panel may be placed inside the Canopy or at the suitable outdoor location as per latest norms and site conditions.
1
-
-
... More
2. FSD Sawai madhopur
-
-
-
... More
Supply, Installation, testing and commissioning of 30 kVA Silent type Liquid cooled diesel driven generating set conforming to CPCB IV+ norms comprising of radiator, 4 stroke multi cylinder engine of minimun 35 BHP to deliver rated kVA at prevailing site conditions equipped with flywheel, residential type silencer, fuel governor, fuel pump/ CRDI, built in fuel tank, electric starting equipment with required nos of suitable AH sealed maintenance free batteries etc., directly coupled to 30 kVA 0.8PF (lag), alternator suitable for 3 phase, 4 wire 50Hz AC supply system with the entire system mounted on common base frame etc. on an existing foundation, exhaust piping with thermal insulation, control wiring from Alternator to control panel, acoustic enclosure, etc. as specified and consisting of the followings and AMF panel as per specification given in the detailed specifications sheet as attached in the DG set Speifications section etc. as required.; Diesel Engine: One number Diesel Engine multi-cylinder, four stroke, liquid cooled, electric start, turbo charged type engine suitable for developing the required BHP at 1500 rpm, suitable for above output of alternator at 40º C, 50% RH and at 1000 Metre MSL and conforming to BS 5514, BS 649, IS:10000, ISO 8528 Part I with upto date amendments/ norms, capable of taking 10% over loading for one hour after 12 hours of continuous operation complete with common base frame, Anti vibration mountings, radiator, starting equipment, batteries, residential type silencer and other accessories etc. as required and as specified in the detailed specification enclosed in the DG set Specifications section. Governing Class (As per ISO 8528 part-V) ; Noise Level ≤ 75 dBA at a distance of 1m (IS 8528-10)/as per latest CPCB NORMS ; Fuel Tank Capacity-minimum 60L / to run minimum of 8hr in one time full refilling ; Weight of Gen Set with Canopy- Wet- minimum 750 Kgs (or as per Manufacturer standards) ; Electrical Battery Starting Voltage-12 V DC
Engine Specifications- Rated Output (Prime continuous Rating as per ISO 8528-1)-24 kW/ minimum 35 HP ; No of Cylinders-3; Rated Speed at 1500 RPM
Aspiration - Turbo Aspiration ; Lube Oil Sump Capacity- minimum 7L; Coolant Capacity- minimum 10L
Alternator: Insulation-Class H ; Efficiency at (100% Load)-0.8 pf (As per Standards IS 4722, IEC 34-1)-86% with voltage regulator ±1% ; Max time to build Rated Voltage at Rated RPM-Voltage Recovery TIme-6 sec
1
-
-
... More
Supplying, installation, testing and commissioning of automatic mains failure control suitable for 30kVA including By pass panel of 16SWG CRCA sheet floor mounted type, weather proof, corrosion resistance, water proof, Powder coated, powder painted, 7 tank process with suitable rating of 02 nos. FP MCCB, 02 nos. FP Contactors, aluminium bus bar/ 4 way terminal connector for Grid, DG output and common output as approved by Engineer in Charge, suitable for required capacity of silent type DG site complete with relays, timers, set of CTs for metering & protection and energy analyser indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF Panel to diesel Engine and else where if required all complete and inter locking including all the required installations as mentioned in detailed specification sheet for DG set etc. as required. The AMF Panel may be placed inside the Canopy or at the suitable outdoor location as per latest norms and site conditions.
1
-
-
... More
3. BC Sawai Madhopur
-
-
-
... More
Supply, Installation, testing and commissioning of 125 kVA Silent type Liquid cooled diesel driven generating set conforming to CPCB IV+ norms comprising of radiator, 4 stroke multi cylinder engine of minimum 150 BHP to deliver rated kVA at prevailing site conditions equipped with flywheel, residential type silencer, fuel governor, fuel pump/ CRDI, built in fuel tank, electric starting equipment with required nos. of suitable AH sealed maintenance free batteries etc., directly coupled to 125 kVA 0.8PF (lag), alternator suitable for 3 phase, 4 wire 50Hz AC supply system with the entire system mounted on common base frame etc. on an existing foundation, exhaust piping with thermal insulation, control wiring from Alternator to control panel, acoustic enclosure, etc. as specified and consisting of the followings and AMF panel as per specification given in the detailed specifications sheet as attached in the DG set Specifications section etc. as required.; Diesel Engine: One number Diesel Engine multi-cylinder, four stroke, liquid cooled, electric start, turbo charged type engine suitable for developing the minimum 150 BHP at 1500 rpm, suitable for above output of alternator at 40º C, 50% RH and at 1000 Metre MSL and conforming to BS 5514, BS 649, IS:10000, ISO 8528 Part I with upto date amendments/ norms, capable of taking 10% over loading for one hour after 12 hours of continuous operation complete with common base frame, Anti vibration mountings, radiator, starting equipment, batteries, residential type silencer and other accessories etc. as required and as specified in the detailed specification enclosed in the DG set Specifications section. Governing Class (As per ISO 8528 part-V) ; Noise Level ≤ 75 dBA at a distance of 1m (IS 8528-10)/as per latest CPCB NORMS ; Fuel Tank Capacity-minimum 200L / to run minimum of 8hr in one time full refilling ; Weight of Gen Set with Canopy- Wet- minimum 1800 Kgs (or as per Manufacturer standards) ; Electrical Battery Starting Voltage-12 V DC
Engine Specifications- Rated Output (Prime continuous Rating as per ISO 8528-1)-100 kW/ minimum 150 HP; No of Cylinders-4/6; Rated Speed at 1500 RPM
Aspiration - Turbo Aspiration; Lube Oil Sump Capacity- minimum 10L; Coolant Capacity- minimum 18L
Alternator: Insulation-Class H; Efficiency at (100% Load)-0.8 pf (As per Standards IS 4722, IEC 34-1)-90% with voltage regulator ±1%; Max time to build Rated Voltage at Rated RPM-Voltage Recovery TIme-6 sec
1
-
-
... More
Supplying, installation, testing and commissioning of automatic mains failure control suitable for 125kVA including By pass panel of 16SWG CRCA sheet floor mounted type, weather proof, corrosion resistance, water proof, Powder coated, powder painted, 7 tank process with suitable rating of 02 nos. FP MCCB, 02 nos. FP Contactors, aluminium bus bar/ 4 way terminal connector for Grid, DG output and common output as approved by Engineer in Charge, suitable for required capacity of silent type DG site complete with relays, timers, set of CTs for metering & protection and energy analyser indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF Panel to diesel Engine and else where if required all complete and inter locking including all the required installations as mentioned in detailed specification sheet for DG set etc. as required. The AMF Panel may be placed inside the Canopy or at the suitable outdoor location as per latest norms and site conditions.
1
-
-
... More
EARTHING WORK
-
-
-
... More
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
6
-
-
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
6
-
-
... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
30
-
-
... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
12
-
-
... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.l. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
30
-
-
... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
12
-
-
... More
SUPPLY AND LAYING OF SERVICE CABLE
-
-
-
... More
Supplying of XLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date ammendments of the following size as required.
-
-
-
... More
3½ x 35 sq. mm
80
-
-
... More
3½ x 95 sq. mm
40
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
3½ X 35 sq. mm (32mm)
8
-
-
... More
3½ x 95 sq. mm (45 mm)
4
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
-
-
-
... More
upto 35 sq. mm
16
-
-
... More
Above 35 sq. mm and Upto 95 sq mm
8
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
... More
Above 35 sq. mm (clamped with 1mm thick saddle)
16
-
-
... More
Above 35 sq. mm and Upto 95 sq mm (clamped with 25*3 mm MS flat clamp)
8
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
-
-
-
... More
upto 35 sq. mm
12
-
-
... More
Above 35 sq. mm and Upto 95 sq mm
6
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
... More
upto 35 sq. mm
36
-
-
... More
Above 35 sq. mm and Upto 95 sq mm
18
-
-
... More
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
6
-
-
... More
CIVIL WORKS
-
-
-
... More
Providing foundation and platform for the 30 kVA Silent type DG set so as to place the above mentioned DG Set conforming to clause 2.5.1 of General specifications for Electrical Works Part - VII DG Sets 2013 including PCC & suitable CC mix as recommended by OEM/ Manufacturer.
-
-
-
... More
At FSD keshorai patan
1
-
-
... More
At FSD Sawai madhopur
1
-
-
... More
Providing foundation and platform for the 125 kVA Silent type DG set so as to place the above mentioned DG Set conforming to clause 2.5.1 of General specifications for Electrical Works Part - VII DG Sets 2013 including PCC & suitable CC mix as recommended by OEM/ Manufacturer.
-
-
-
... More
At BC Sawai Madhopur
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements