Central Electronics Engineering Research Institute Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Central Electronics Engineering Research Institute - CEERI Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Oct 2023
Closing Date1 Nov 2023
Tender Amount₹ 19,09,851 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Above 240 sqmm up to 400 sqmm.

50

-

-

... More
2 x 10 Sqmm.

50

-

-

... More
75 mm x 90 mm

3

-

-

... More
Group B (for Above type-III Qtrs.)

10

-

-

... More
Rewinding of ceiling fan motor (starting & running winding) including all necessary material. The motor is to be wound taking no. of coil,turns and pitch as it was originally wound with required size supper enamelled wire with E class insulation material and making connnectionsetc. as required.

-

-

-

... More
Supply & Fixing of M.S. nut bolts with washers of irrespective of sizes

10

-

-

... More
Supplying & fixing following modular type switch/ socket on the existing modular plate, switch box including after removing the old switch,socket, connections but excludind modular plate etc. as requierd. And deposit in the store.

-

-

-

... More
P/ F T/L rotary type side holder on pole. Make – Philips

4

-

-

... More
Supplying & Laying earth conductor from electrode on surface or in recess for loop earthing with iron saddles including making connections duly soldered or crimped with GI thimble as required.

-

-

-

... More
5 Watt- LED bulb

12

-

-

... More
Single phase 30/40 Amp.

40

-

-

... More
12 Watt LED bulb

20

-

-

... More
Testing of submersible motor pump set at the surface tank at O.H. tank site including assembling, making connections as required & taking current and voltage reading, checking water discharge etc. as required.

5

-

-

... More
Single pole

62

-

-

... More
4Pole isolator 100Amps., 415 Volts.

3

-

-

... More
2 Way 5/6 amper switch

20

-

-

... More
Earthing as per IS:3043 with G.I earth plate 600 x 600 x 6mm thick including accessories embodying by digging 4mtr below the ground lavel with alternate layers of salt and charcoal (95 kg. each) with 20mm dia G.I. B class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete and testing of earth resistance as required.

2

-

-

... More
Dismantling of defective 20HP mono block pumpset from the suction / delivery line including electrical wires disconnection etc. as req., shifting the same in colony store and again shifting the reapired pump set from colony store to the pump house, installation the same pump including fixing of suction /delivery line, making electrical connection, testing, commissioning etc. as req.

2

-

-

... More
Supply and fixing of GI pipes with flanges duly screwed & welded including rubber washer, nut & bolts complete in all respect tata, jindal, swatik etc.

-

-

-

... More
2X 2.5 sqmm + 1 X 2.5 Sqmm

130

-

-

... More
S &F 3mm thick paper phenolic resin bonded laminated confirming to IS, 2036-1955 for box/frames including making holes for switch etc, with brass screw, washer/zink plated nut & bolts as reuired make Formica, Greenlam, Bakelit hylem.

-

-

-

... More
Above 240 sqmm up to 400 sqmm.

40

-

-

... More
120 Sq.mm.

2

-

-

... More
5/6 Amper switch

30

-

-

... More
Erection of steel tubular pole of length exceeding 8 metres but not exceeding 10 meters in cement concrete 1;3;6[1 cement ;3 coarse sand ;6 graded stone aggregate 40 mm nominal size ] foundation inculding excavation and refilling etc as required.

1

-

-

... More
9 Watt- LED bulb

12

-

-

... More
Bell switch

20

-

-

... More
Laying of one number cable as per specification of above in the existing RCC/ hume/ Stoneware/ Metal pipe including making connections both side and testing etc as rqd.

-

-

-

... More
GI pipe B class 50mm dia

48

-

-

... More
5/6 Amper switch

400

-

-

... More
Laying of cable as per specification of above item on wall, pole or surface including fixing with wooden plugs as per approved spacings by means of screws & rag bolts, M.S.U. clamps etc complete as per specifications including making connections and testing etc

-

-

-

... More
Wiring for light point/fan point/Exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor cable as per following types of wiring.

-

-

-

... More
Cleaning of mud/ sand deposited in 20000 gallons capacity surface tank and ther after washing with fresh water and drain out of above water including supply of required materials like broom (jhadu) etc.

1

-

-

... More
Supply & making straight through joint with shrinkable kit including ferrules and other jointing material for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 Kv grade as reqd.

-

-

-

... More
Cleaning of exhaust fan with shutter of colony quarters/ Guest house /dispensary, including removing from wall, cleaning with kerosine, soap, cloth and refixing the same, making connections etc. as required.

126

-

-

... More
P/F 2x1.5 sqmm. FRLS PVC copper wires, 1100V grade from OH supply line to Street light fitting . As required.

20

-

-

... More
Labour Chargees for cleaning of following items inclding supply of soap, powder, cloth, any cleanning agent etc. as reqd.

-

-

-

... More
Dismantling and re-laying of PVC/ XLPE insulated armoured HT cable ( for 11 KV line ) from pole/ surface on wall disconnection and also making connection, testing etc.

-

-

-

... More
Erection of steei tubular pole of length exceeding 4.5 metres but not exceeding 6.5 meters in cement concrete 1;3;6[1 cement ;3 coarse sand ;6 graded stone aggregate 40 mm nominal size ] foundation inculding excavation and refilling etc as required.

1

-

-

... More
P & F of gravity louver shutter of superior quality made out of frame of 18 SWG MS sheet & louvers made from 24 swg Al. sheet with nut bolts enamel paint etc as required. Up to 380mm.

25

-

-

... More
6 pin 15/16 Amper Socket

120

-

-

... More
4 X 35 Sqmm.

2

-

-

... More
P & F Of rubber gromet (fan insulator )any size,

35

-

-

... More
9.0 Mtr long (200 Kg) as per Discom specification

1

-

-

... More
Supplying & fixing double pole (single phase & neutral) 240 volts 40 ampers RCCB having a sansitivity current 30 mA in the existing MCB DB complite with connections, testing and commissioning etc .as requred.

30

-

-

... More
P/ F Electronic 36 watts ballast for fluorescent tube light fixtures on pole including removing of old ballast. Make- Philips EBE-136 or equivalent.

5

-

-

... More
Checking of fuse cut outs fitted on poles and found if burnts same will be replaced by new fuse wire including supply of fuse wire , carry of required size ladder etc. as required.

60

-

-

... More
12 mm thick.

1

-

-

... More
Making proper sag adjustment of O.H. lines conductor AL./ Copper irrespective of sizes including removing of binding wires from insulator and refixing the same for the whole works ( Labour works only but Contractor should arrange all the tools etc like wire vice, rope, spanners etc and department will not make any extra payment for the same ) Rate as per one span but number of wires as required in between two poles

20

-

-

... More
200mm X 150mm X 60mm

10

-

-

... More
Double pole

32

-

-

... More
8 SWG G.I. wire(hot dipped)

50

-

-

... More
Repair of water level gauge by replacing of pully, steel wire and making proper level adjustment and alignments etc. complete with all accessories.

1

-

-

... More
Supplying & drawing following sizes of medium class PVC conduit along with the accessories in surface/ ressed including cutting the wall and making good the same in case of rscessed conduit as required.

-

-

-

... More
63 A , 415 Volts

30

-

-

... More
S/F metal box of 150mm x 75mm x 60 mm surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amp piano type switch, connections, painting etc. as required.

7

-

-

... More
Supply of XLPE insulated PVC sheathed 1.1 kv. Grade Aluminium conductor armoured Cable, IS marked of approved make.

-

-

-

... More
P / F metal clad industrial plug top 3 pin for 16/20 amper socket as required.And deposit in the store.

15

-

-

... More
upto 35 Sqmm.

250

-

-

... More
Delowering Only

3

-

-

... More
Triple pole and neutral

8

-

-

... More
185 Sqmm to 240 Sqmm.

70

-

-

... More
Supplying & Laying 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode, including connections terminating with nut ,bolt,spring, washer etc.as requierd. (Jointing shall be done by overlapping & with 2 sets of brass nut bolt & spring washer) duly soldered or crimped etc. as required

40

-

-

70

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. Fittings including trenching (75 cm deep) and re-filling etc. as required.

-

-

-

... More
3.5 x 240 Sq. mm

1

-

-

... More
Up to 120 sqmm.

50

-

-

... More
Upto 25 Sq. mm

7

-

-

... More
upto 35 Sqmm.

250

-

-

... More
Labour charges for installation of submerible motor pump set including Lowering/ Delowering of pipes, cables, accessories etc. in tubewell complete including electrical connection, disconnection, T&P, transpotation of tripod, chian pully block & any other materials as nut & bolts, rubber gasket/ seat as required for this purpose.

-

-

-

... More
Providing and replacement of M.S shaft of exhaust fan of any size fitted in Colony Qtr.

5

-

-

... More
Group A (for upto type-III Qtrs.)

15

-

-

... More
Supplying & drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface/ ressed steel/ PVC Cassing Capping as required.

-

-

-

... More
S &F metal box of following sizes nominal size surface/recess with suitable size of phenolic laminated sheet cover infront including painting as required.

-

-

-

... More
Fixing of jumpher wires or joints at both ends for existing O.H. lines irrespective of sizes on pole, per job consist of two ends of single wire joint or re-jumphering either in O.H. lines or in kitkat fuse. ( Labour works only )

150

-

-

... More
P/F 25mm x 5mm copper strip in 40mm dia G.I. Pipe from earth electrode.including connection with brass nut bolt spring washer excavation and refilling as rqd.

30

-

-

... More
100 mm x 110 mm

3

-

-

... More
Making hole in the road for laying G.I.pipe up to 80mm dia./ cable with all necessary T & P reqd.

8

-

-

... More
Providing & fixing heating element (Indirect / Direct type ) ISI marked for 25 / 35 litres capacity vertical; type geyser including gasket etc. as reqd.(make- Bajaj,CG,Usha,Almonard)

-

-

-

... More
Dismantling of PVC/ XLPE insulated armoured LT cable, 1.1 KV grade from surface of wall/ pole including after disconnection of connections, clamps , return back to store etc.

-

-

-

... More
Repair of street light fixtures of all types i.e. FTL/ CFL/ LED/ MH/ Sodium including find the location of fault in the fittings component i.e. bulb, chock ,ignitor, capacitor etc. as required (Labour work)

4

-

-

... More
180mm X 100mm X 60mm

10

-

-

... More
3.0 mm thick

2

-

-

... More
Providing and fixing fan capacitor 2.0/ 2.5 mfd, 250V, 50 hz rating . after removing old capacitor and deposit in the store. Make .usha/punsum/priya/tibcon/capital/jec.

155

-

-

... More
P & F Bakelite sheet of following thickness on the R.C.C. pole including fixing of nut-bolts, drilling holes etc. as reqd. for fixing of porcelain cutouts.( Make – Hylam , Formica )

-

-

-

... More
Making straight through joint of overhead lines copper/ Al. conductor of irrespective sizes including supplying of reqd. materials , drawing of OH wires giving required sag, making both end terminations on pole, supplying all the materials, T & P etc. as reqd.

12

-

-

... More
3.5 x 400 Sq.mm

2

-

-

... More
6 pin 15/16 Amper Socket

20

-

-

... More
120 sqmm to 185 sqmm. 11KV HT cable

2

-

-

... More
7" stem thermostat

12

-

-

... More
15/16 Amper switch

120

-

-

90

-

-

... More
5 pin 5/6 Amper socket

20

-

-

... More
Cleaning of Ceiling fan in position in guest house/ office rooms.

80

-

-

... More
P & F ISI marked flush type 120/280 watt rotary step fan regulator Delux type or two module including making connection testing etc. as required

115

-

-

... More
Supplying & fixing following piano type switch/ socket on the existing switch box/ cover including after removing the old switch,socket, connections etc. as requierd. And deposit in the store.

-

-

-

... More
Delowering & lowering .

6

-

-

... More
ITC of ceiling fan and exhaust fan including wiring the down rod with 1.5 sq mm FRLS PVC insulated copper conductor, making connections, testing etc. After removing the old fan diposit in store.

20

-

-

... More
100 mm X 100mm X 60mm

12

-

-

... More
1000 watt

24

-

-

... More
Supplying & fixing PVC batten/ angle bulb holder on the existing junction box/wooden block including after removing the old bulb holder, connections etc. as requierd. And deposit in the store.

160

-

-

... More
Cleaning of Tube light / CFL/ LED fittings at guest house/ office rooms

70

-

-

... More
Providing and replacement of ball bearing of ceiling fan/ exhaust fan as required (NBC/SKF) And deposit in the store.

50

-

-

... More
900/1200/ 1400 mm sweep

36

-

-

... More
Dismantle LED/ T/L defective street light / flood light fitting from the bracket of the top of the pole including making disconnection & refixing the another LED street light / flood light fitting including making connection testing etc. as required irrespective of any wattage of fitting etc. as reqd.

80

-

-

... More
Cutting black top/cement concrete surface upto 0.5 mtr depth including all layers of crust for laying pipe line etc. and making good to original conditions including cost of bitumen ,cement,bajri etc. as reqd.

3

-

-

... More
Supplying and filling gland rope uptu 20HP mono block pumpset including removing old defective gland etc.

5

-

-

... More
80 mm dia (nominal)

12

-

-

... More
35 Sq.mm to 50 Sq. mm

3

-

-

... More
Making joint of GI wire of irrespective size including supplying of reqd. materials, T & P etc.including drawing in OH line.

12

-

-

... More
P/F earth connection from earth electrode with 6SWG dia.G.I. wire in 15mm dia. G.I. Pipe from earth electrode.including connection with thimble excavation and refilling as rqd.

40

-

-

... More
Up to 120 sqmm.

70

-

-

... More
upto 35 Sqmm.

40

-

-

... More
80 sq. mm of (6+1),4.09 mm (Raccon)

20

-

-

... More
4 x 25 Sqmm.

100

-

-

... More
Repair of street light fixtures Jumper wire as required (Labour work)

125

-

-

... More
Temporary fixing & removal of 3-phase Kwh meter with box on pole along with TPN switch and making all connections to O.H. line conductors after taking proper line shut down etc. as reqd. (Labour works only )

15

-

-

... More
6 SWG Copper wire

50

-

-

... More
200A, 415 Volts

15

-

-

... More
Trimming & cutting of tree branches on the road side adjacent to electrical LT/HT over head lines including line off & line on, shifting of all the tree branches to the nearest dustbin in ceeri colony. ( To be engaged 2 labours per day )

400

-

-

... More
S /F MS Flat iron 25mm x6mm for submercible pump jhula safety guard etc as reqd.

4

-

-

... More
Provide and Fixing of IP 51 direct single phase 220/240 volts ,50Hz static watt hour meter having resolution 1 accuracy class,LED indicators, electromechanical counter,LEDdisplay, cover plate for body and terminal sealing , including sealing,making connection testing, after removing the old meter as required.And deposit in the store. (Make L&T ONLY)

-

-

-

... More
S/F metal box of 180mm x 100mm x 60 mm surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/15 amps socket outlet and 15 amp piano type switch, connections, painting etc. as required.

7

-

-

... More
Supply & fixing of Porcelain shackle insulator as per IS:1443 1979 suitable for working voltages on 1100 V including hot dipped GI accessories and heavy duty hard wares etc. as reqd.

-

-

-

... More
15/16 Amper switch

20

-

-

... More
120 sqmm to 185 sqmm. 11KV HT cable

2

-

-

... More
Lowering Only

3

-

-

... More
185 Sqmm to 240 Sqmm.

45

-

-

... More
6 SWG G I Wire

50

-

-

... More
Supplying & drawing following sizes hard drawn copper/ GI wires on existing cross arms through insulator/ on poles with all necessary T & P reqd. including binding and twisting, connections etc. as reqd..

-

-

-

... More
S & F of 32mm dia X 2 meter long G.I. pipe (medium class) bracket for mounting of fluorecent/ HPMV/ LED street light fitting on pole including bending the pole to the required shape, 2 nos 40mm X 3mm flat iron clamps with nuts, bolts and washers, painting the flat iron with primer and finish paint etc. as required.

2

-

-

... More
100 sq. mm of (6/4.72mm+1/1.57mm), (Dog)

20

-

-

... More
DP isolator 63Amps., 240 Volts.

2

-

-

... More
4 x 35 Sqmm.

150

-

-

... More
50 mm dia (nominal)

12

-

-

... More
Dismantling and re-laying of PVC/ XLPE insulated armoured HT cable ( for 11 KV line ) from under ground including digging trenches up to 1.2mtr depth & refilling the same after disconnection and also making connection, testing etc.

-

-

-

... More
Plate Earthing as per IS:3043 with copper earth plate 600 x 600 x 3 mm thick by embodying 4 mtr below the ground lavel with alternate layers of salt and charcoal (95 kg. each) with 20mm dia G.I. B class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete and testing of earth resistance as required.

3

-

-

... More
above 35 Sqmm upto 95 Sqmm.

40

-

-

... More
240 sqmm 11KV HT cable

2

-

-

... More
Charges for oiling, greasing, overhauling of ceiling fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required.

100

-

-

... More
supplying & fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, MCB suitable for inductive load of folloing pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Triple pole

8

-

-

... More
Bell switch

5

-

-

... More
Supply of XLPE insulated PVC sheathed 1.1 kv. Grade copper conductor armoured Cable 2 x 4 sqmm IS: 7098 Part-1 of approved make.

250

-

-

... More
Supplying and making outdoor end termination with heat shrinkable/cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
S/F PVC cassing capping (I;s 14927 p-ii) along with accessories as required.

-

-

-

... More
P & F LED bulb direct fit (Retrofit) in existing holder( threaded type/ BC/ press fit etc ) on poles fitted fixture (upto 15 feet height ) including repair as required ( Philips make )

-

-

-

... More
Removing and refixing of 25/35 litres capacity vertical type storage water heater/ geyser including dismantle cleaning/descaling it by help of acid etc. and reassemble the same including supply of nuts , gasket etc. as reqd for the complete work

12

-

-

... More
20 mm x 12mm

100

-

-

... More
S&F T.P sheet steel encloser on surface /recess along with 32 amp. 415 volts C curve TP. MCB complete with connections testing commissing etc.as requred.

4

-

-

... More
Removing of body of burnt birds, peacock or any such type of animals from LT/HT over head lines & shifting the same out side of CEERI compus.

8

-

-

... More
Labour Charges for fixing of water tight wall bracket fitting of all size and shapes containing CFL/LED lamps fitting complete with all accessories including connection etc. as required.(wall bracket/ ceilling light fitting suppled by dept.)

20

-

-

... More
4Pole isolator 63Amps., 415 Volts.

3

-

-

... More
Supplying & fixing call bell/ ding dong suitable for single phase ,230 volts on the existing box/wooden block including after removing the old call bell/ ding dong , connections etc. as requierd. And deposit in the store.

30

-

-

... More
Supplying and drawing L.T. overhead steel core aluminium conductor ( ACSR ) on existing cross arms through insulator with all necessary T & P reqd. including binding and twisting etc. complete in all respect as reqd.

-

-

-

... More
Supply and erection of P.C.C./R.C.C. pole as per REC manual no 15/1979 conforming to IS: 2905/1966 as per requirement of sec3 in alignment, including excavation of pit and back filling with stone aggregate/boulders layer of 0.45m by ramming and watering etc complete in all respectand soil in 0.45m consolidating each deposited

-

-

-

... More
To locate/ idenify the fault of supply in line/ wiring in the Qrts/ pump sets/ pond pump set/ CVM/ DDK/ Street light/ O.H. lines/ Shopping center/ club/ sports ground/ guest house/ O.H./ N.H./ Appartments/ dispensary and rectify the same immediately including providing required manpower, T & P etc. as required.

400

-

-

... More
Supplying & fixing PVC box of size 75mm x 75mm x 50mm for bulb holder, ceiling rose after removing the old board / round block etc as required..

30

-

-

... More
Laying of PVC/ XLPE insulated PVC sheathed of 1.1 Kv grade with aluminium conductor armoured cable in ground as per IS:1255 including excavation of 30cmx75cmsize trench, 25cm thick under layer of sand, II nd class brickes covering refilling earth, compaction of earth, making necessary both side connections testing etc. as reqd.of following sizes.

-

-

-

... More
Cleaning of any size switch boards with switches,sockets etc., in the guest house/ office rooms

130

-

-

... More
above 35 Sqmm upto 95 Sqmm.

70

-

-

... More
240 sqmm 11KV HT cable

2

-

-

... More
Transportation charge of monoblock pumpset colony pump house to pilani workshop and come back including loading unloading etc as rqd

2

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE Al. Conductor cable of 11KV grade as required.

-

-

-

... More
Making water proof joint 2x3 core flat PVC filexible cable 2.5/4 /6sqmm size for submersible pumpset including supplying jointing materials, pvc tape etc as required.

10

-

-

... More
Supplying & fixing 3pin , 5 amper ceiling rose on the existing junction box/wooden block including after removing the old ceiling rose, connections etc. as requierd.And deposit in the store.

40

-

-

... More
Fixing the ceiling fan/ exhaust fan after removing the old fan including disconnection & making connection, testing etc. as required.

10

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE Al. Conductor cable of 11KV grade as required.

-

-

-

... More
Extra P /F Flourescent type 36 watt tube light rod in existing frame on pole , Make - Philips

10

-

-

... More
Supplying and fixing 20Amp, 240volts, SPN industrial type, socket outlet, with 2 pole and earth metal inclosed plug top along with 20Amp 'C' series, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained matal cover for the socket out let and complete with connections, testing etc. as required.

30

-

-

... More
100A, 415 Volts

15

-

-

... More
above 35 Sqmm upto 95 Sqmm.

250

-

-

... More
Dismantling of overhead lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.

20

-

-

... More
P & F stem type ISI marked(IS 3017/85) snap action adjustable thermostat for storage water heater including making connection ,testing etc. as reqd.

-

-

-

... More
4 X 25 Sqmm.

8

-

-

... More
S/F of following ratings TPN Isolator in the existing MCB DB complete with connections, testing & commissioning etc. as req.

-

-

-

... More
Cleaning of jhummer fittings at guest house/ office rooms

4

-

-

... More
5 pin 5/6 Amper socket

65

-

-

... More
2Way 5/6 amper switch

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.