Central Electronics Engineering Research Institute Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 14,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_206942_1Bid Award Id
ViewTender No
14/479/2024-CETender Authority
Central Electronics Engineering Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
1
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more.
110
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes
-
-
-
Cement mortar 1:4 (1 cement : 4 coarse sand)
7
-
-
Providing and fixing aluminium body Cam Action Slide Channel Overhead hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment and 90 degree stop arrangement, of approved quality and make with necessary accessories and screws etc. complete.
2
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
-
-
-
Size 250x10 mm
4
-
-
Size 100x10 mm
12
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete
-
-
-
Size 125 mm
6
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
-
-
-
40 mm thick with 20 mm nominal size stone aggregate
7
-
-
12 mm cement plaster of mix
-
-
-
1:6 (1 cement: 6 coarse sand)
20
-
-
15 mm cement plaster on rough side of single or half brick wall of mix:
-
-
-
1:6 (1 cement: 6 coarse sand)
35
-
-
Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.
-
-
-
Ordinary cement finish using ordinary cement
15
-
-
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
-
-
-
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
17
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade :
-
-
-
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
22
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
17
-
-
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required and including water thinnable priming coat with cement primer, to achieve even shade & colour and scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
-
-
-
Old work (Two or more coats)
35
-
-
Providing and fixing bright finished hooks and eyes in aluminium , ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade and approved quality and make with necessary screws etc. complete
-
-
-
Size 150 mm
6
-
-
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within CEERI campus as per direction of Engineer-In-Charge.
3
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
-
-
-
For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
230
-
-
For shutters of doors, windows & ventilators including providing and fixing strainless steel hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
85
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
-
-
-
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
12
-
-
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
1
-
-
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge
-
-
-
Anodized (AC 15 ) aluminium
4
-
-
Providing and fixing homogeneous Polyvinyl chloride sheet / tile in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhesives of approved quality and manufacturer like Dunlop S-758, Fevicol SR 998 or equivalent including welding of joints if required and rolling with light wooden roller weighing about 5 kg., all complete as directed by Engineer-in-Charge, in approved colour and shade including removal of old pvc flooring if required & preparing the smooth surface etc. as per direction of Engineer - in - charge.
45
-
-
Providing and Fixing 0.50 mm thick PVDF (Poly Vinylidene fluouride) of aluminium thickness 3.00 mm overall thickness 4.00 mm on walls,in doors & ceiling with proper required haging system and having fire rating of 120 minutes and fixing with silicon tape/ adhessive material as required ,in opening shutters and fixed sections including cutting PVDF sheet as per required at site, preparing smooth surface and making holes/making good as required cutting hoisting and fixing aluminium members etc. complete as directed by Engineer-In-Charge
14
-
-
Repairs of reveals and jambs of doors and windows with cement mortar 1:3 (1 cement : 3 fine sand) including chiseling the damaged area and disposal of mulba in low laying area in CEERI Campus as per direction of Engineer-In-Charge.
10
-
-
Chisselling the flaked and cracked RCC slabs ceiling plaster and replastering the same in c.m. 1:3(1 cement:3 coarse sand) of sufficient thickness to cover the exposed reinforcement and make the ceiling smooth including finishing as per existing as per direction of Engineer-In-Charge.
5
-
-
Part 'B' Electrical Work :- Point Wiring - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
10
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base, cover & blanking plate for modular switches in recess etc. as required. etc as required.
-
-
-
1 or 2 Module (75mmX75mm)
16
-
-
8 Module (125mmX125mm)
1
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 A switch
6
-
-
3 pin 5/6 A socket outlet
1
-
-
Telephone socket outlet RJ 11
3
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3pin, 6 amps modular socket outlet with 1 No. 16 amp moduler switch and 1No. 6 pin 5/6 & 15/16 amps modular socket with 1no 16 amp moduler switch, blanking ,connection, painting etc. as required (different in colour of cover plate from general power for UPS / computer applications), making good the wall with matching colour distemper/ white wash etc. as required. (anchor penta or equivalant make)
11
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, making connections and testing etc. as required.
9
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
35
-
-
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
60
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
60
-
-
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
60
-
-
Telephone & Data :- Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
2 Pair
60
-
-
Supplying & Fixing of following sizes of steel conduit along with heavy duty accessories, junction box etc. in surface / recesse including painting in case of surface conduit, or cutting the wall, repair and making good the same as required.
-
-
-
20 mm
45
-
-
25 mm
40
-
-
Supplying and drawing of 23 AWG UTP Data Cable (CAT 6) gigaspeed LAN Cable in the existing surface/ recessed Steel/ under floor trunking as required.
-
-
-
1 run of cable
120
-
-
P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts Simplex Faceplate with RJ-45, information outlet with shutter with colour coding on existing modular plate, including making connections testing etc. as required
11
-
-
Light and Fan : - Supply of 400mm size wall mounting oscilating type wall mounting fan having 3 speed push button control suitable for operation on 230volts, 50Hz, AC supply Havells platina or equivalantmake complete with continuous duty, motor, chrome plated front and rear guards etc.
8
-
-
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connection with 1.5 sq.mm PVC insulated copper conductor single core cable as required.
8
-
-
Supply of XLPE insulated PVC sheathed 1.1 kv. Grade copper conductor armoured Cable IS: 7098 Part-1 of approved make.
-
-
-
4 X 25 Sqmm Al. Cable
140
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on wall/ roof/ duct/ shaft including fixing by means of screws & rag bolts, suitable size MS U clamps complete as per specifications, repairing works etc as reqd. of following sizes of cables.
-
-
-
upto 35 Sqmm.(clamped with 1mm thick saddle)
140
-
-
Supply& making one end termination with heavy duty single compression brass gland SIBG type, aluminium/ copper lugs duly crimped with crimping tool, PVC tape etc. for following size of XLPE insulated & PVC sheathed aluminium/ copper cable of 1.1 KV grade as required.
-
-
-
4 X 25 Sqmm Cable
4
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
140
-
-
Distribution Boxes ( Main DBs) :- Supplying and fixing recessed mounted heavy duty double door ,4 Way three pole and neutral, MCB distribution board, 415 volts on surface / recess, complete with loose wire box, tinned copper bus bar,neutral links, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted, making internal DB terminations with copper lugs including all the existing incoming/ outgoing connections, earthing, testing, repair & making good the wall with matching colour distemper/ white wash etc. as required.(But without MCB/RCCB/Isolator)
3
-
-
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
63 Amp
3
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single Pole (10-32)