Bharat Sanchar Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 11,432Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/5587208Tender No
GEM/2024/B/5587208Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
technical_spec_2024-11-08-12-46-09_6d53bec4144e88bda0d9ffd8ffd07225.pdf
boq3_2024-11-08-12-46-09_ca69acc313eb98dbb63e7ae6ab0cef00.csv
BOQ Items
Pdg and Making of General Servicing of the EA sets , Pdg and Making of General Servicing of More than 32.5 KVA and Upto 55 KVA DEA Sets of different make and model installed at Sites including complete checking of EA Set after servicing and replacement of consumables
2
-
-
Replacement of the Diesel Filter Element Set of 1 Ltr capacity , Replacement of the Diesel Filter Element Set of 1 Ltr in existing Different capacity and make of Engines including dismantling of faulty parts, fixing the new in place of faulty parts
4
-
-
Replacement of the oil Filter Element Set of 0.5 Ltr capacity , Replacement of the Oil Filter Element 0.5 Ltr in existing Different capacity and make of Engines including dismantling of faulty parts, fixing the new in place of faulty parts
12
-
-
Replacement of the oil Filter Element Set of 1.0 Ltr capacity , Replacement of the Oil Filter Element 1.0 Ltr in existing Different capacity and make of Engines including dismantling of faulty parts, fixing the new in place of faulty parts
4
-
-
Replacement of the Diesel Filter Element Set of 0.5 Ltr capacity , Replacement of the Diesel Filter Element Set of 0.5 Ltr in existing Different capacity and make of Engines including dismantling of faulty parts, fixing the new in place of faulty parts
12
-
-
Replacement of the oil Filter Element Set of 50 and 55 KVA EA capacity , Replacement of the Oil Filter Element sets in 50 and 55 KVA EA capacity including dismantling of faulty parts, fixing the new in place of faulty parts
2
-
-
Replacement of Lubricating Oil Multi Grade , Replacement of Lubricating Oil Multi Grade in existing Different capacity and make of Engines
100
-
-
Replacement of Steel Wire Braided Fuel Pipe Line , Replacement of Steel Wire Braided Fuel Pipe Line in existing Different capacity and make of Engines
50
-
-
Replacement of Stop Solenoid 12 Volt , Replacement of Stop Solenoid 12 Volt in existing Different capacity and make of Engines
1
-
-
Replacement of Starting Key with Switch , Replacement of Starting Key with Switch in existing Different capacity and make of Engines
5
-
-
Replacement of Mechanical Type RPM Cum Hr Meter , Replacement of Mechanical Type RPM Cum Hr Meter in existing Different capacity and make of Engines
1
-
-
Replacement of Mechanical Type RPM Cum Hr Meter Chain , Replacement of Mechanical Type RPM Cum Hr Meter chain in existing Different capacity and make of Engines
1
-
-
Replacement of Battery Leads Red and Black Standard Length and Size including terminals , Replacement of Battery Leads Red and Black Standard Length and Size including terminals in existing Different capacity and make of Engines
5
-
-
Replacement of Coolant for Radiator , Replacement of Coolant for Radiator of superior quality or as recommended by manufacturer in existing Different capacity and make of Engines
10
-
-
Replacement of V Belt , Replacement of V Belt in existing Different capacity and make of Engines
5
-
-
Replacement of Hose pipe set with clips , Replacement of Hose pipe set with clips in existing Different capacity and make of Engines
2
-
-
Replacement of Techo Drive Unit , Replacement of Techo Drive Unit in existing Different capacity and make of Engines
1
-
-
Replacement of Fuel Feed Pump assembly. , Replacement of Fuel Feed Pump assembly in existing Different capacity and make of Engines
5
-
-
Replacement of Solid state SMPS or SCR based battery chargers , Replacement of Solid state SMPS or SCR based battery chargers suitable up to 12V, 180 AH Battery
8
-
-
Replacement of Push Button Switch for Start , Stop, Reset , Replacement of Fuel Feed Pump assembly in existing Different capacity and make of Engines
2
-
-
Replacement of 12 V DC or 220 V AC HR Meter Counter Type , Replacement of 12 V DC or 220 V AC HR Meter Counter Type in existing Different capacity and make of Engines
5
-
-
Supplying and fixing of 12 Volt Battery Operated Self Starter , Supplying and fixing of 12 Volt Battery Operated Self Starter suitable for Starting of Engine including fixing the same on the DG set making connections testing etc.
1
-
-
Supplying and fixing of 12 Volt Battery Charging Alternator , Supplying and fixing of 12 Volt Battery Charging Alternator on the existing DG set including making connections testing etc.
1
-
-
Pdg General Servicing and Repairing of Battery Charging Alternator , Pdg General Servicing and Repairing of Battery Charging Alternator or Dynamo that including dismantling greasing and oiling of bearings and other parts , repairing of rectifier assembly , replacement of carbon brush etc.
5
-
-
Repairing and General Servicing of the existing faulty radiator up to 55 KVA DEA Set , Repairing and General Servicing of the existing faulty radiator up to 55 KVA Diesel Engine alternator set by repairing of leakage and cleaning of copper tubes , dismantling of radiator assembly including transportation, and reinstallation after repairing the same etc.
5
-
-
Pdg General servicing and Repairing of 12 Volts Engine Starting Self , Pdg General servicing and Repairing of 12 Volts Engine Starting Self that including dismantling , greasing and oiling of bearing and other parts , replacement Carbon Brush, Housing etc.
5
-
-
Dismantling of existing Up to 20 KVA DEA sets capacity in sound proof canopy , Dismantling of existing Up to 20 KVA DEA sets capacity in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc set from existing position of TE or BTS site under BA Udaipur etc. and repairing of any damage during dismantling by making good the same etc. complete as reqd.
5
-
-
Dismantling of existing More Than 20 KVA and Upto 55 KVA DEA Sets capacity in sound proof canopy , Dismantling of existingMore Than 20 KVA and Upto 55 KVA DEA Sets capacity in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc set from existing position of TE or BTS site under BA Udaipur etc. and repairing of any damage during dismantling by making good the same etc. complete as reqd.
5
-
-
Transportation of existing DEA sets Up to 20 KVA Capacity along with all accessories , Transportation of existing DEA sets Up to 20 KVA Capacity along with all accessories etc from TE or BTS Site of OA under BA Udaipur to Store or Any Place in same BA as directed by Engg. in Charge by transport by truck , Loading Vehicle etc. complete as reqd.
4
-
-
Transportation of existing DEA sets More Than 20 KVA and Upto 55 KVA DEA Sets Capacity along with all accessories , Transportation of existing DEA sets More Than 20 KVA and Upto 55 KVA DEA Sets Capacity along with all accessories etc from TE or BTS Site of OA under BA Udaipur to Store or Any Place in same BA as directed by Engg. in Charge by transport by truck , Loading Vehicle etc. complete as reqd.
4
-
-
Unloading of existing DEA sets Up to 20 KVA Capacity from Loading Vehicle to Place of Shifting , Unloading of existing DEA sets Up to 20 KVA Capacity from Loading Vehicle to Place of Shifting Store along with all accessories etc as directed by Engg. in Charge with the help of chain pulley , Crane , Man power etc. complete as reqd.
5
-
-
Unloading of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity from Loading Vehicle to Place of Shifting , Unloading of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity from Loading Vehicle to Place of Shifting Store along with all accessories etc as directed by Engg. in Charge with the help of chain pulley , Crane , Man power etc. complete as reqd.
5
-
-
Installation, Testing and Commissioning of existing DEA sets up to 20 KVA Capacity on existing foundation , Installation, Testing and Commissioning of existing DEA sets up to 20 KVA Capacity on existing foundation or floor at site along with Canopy and all other accessories including making connections, power and control cable, earthing connections etc. complete as per requirement at Site. Testing Shall also be arranged by Contractor on existing load available at Site for at least one Hour after Commissioning of the DEA Set. Note - All necessary Material, T and P and Skilled Man Power etc. shall be on part of Contractor
3
-
-
Installation, Testing and Commissioning of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity on existing foundation , Installation, Testing and Commissioning of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity on existing foundation or floor at site along with Canopy and all other accessories including making connections, power and control cable, earthing connections etc. complete as per requirement at Site. Testing Shall also be arranged by Contractor on existing load available at Site for at least one Hour after Commissioning of the DEA Set. Note All necessary Material, T and P and Skilled Man Power etc. shall be on part of Contractor
2
-
-
Labour Charges for Top Overhauling of existing DEA Sets up to 20 KVA Capacity of various Make and Model , Labour Charges for Top Overhauling of existing DEA Sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of all the filters like oil filters, diesel filter, air filter, tappet setting, cylinder head and cleaning of all carbonised parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safeties, meters if reqd and calibration of engine as per manufacturer recommendations etc as required.
1
-
-
Replacement of Liner assembly with rubber ring in existing DEA sets up to 20 KVA Capacity , Replacement of the Liner assembly with rubber ring in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
2
-
-
Replacement of Piston Set without Piston Ring Set in existing DEA sets up to 20 KVA Capacity , Replacement of the Piston Set without Piston Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
3
-
-
Replacement of Piston Ring Set in existing DEA sets up to 20 KVA Capacity , Replacement of Piston Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
3
-
-
Replacement of Set of Gasket including Head Gasket in existing DEA sets up to 20 KVA Capacity , Replacement of Set of Gasket including Head Gasket in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
2
-
-
Replacement of O Ring Set in existing DEA sets up to 20 KVA Capacity , Replacement of O Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
2
-
-
Replacement of CR Bearing in existing DEA sets up to 20 KVA Capacity , Replacement of CR Bearing in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
3
-
-
Replacement of Main Bearing in existing DEA sets up to 20 KVA Capacity , Replacement of Main Bearing in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
3
-
-
Replacement of Oil Pressure Gauge in existing DEA sets up to 20 KVA Capacity , Replacement of Oil Pressure Gauge in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
2
-
-
Replacement of Front oil Seal ,Crank Shaft in existing DEA sets up to 20 KVA Capacity , Replacement of Front oil Seal ,Crank Shaft in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
2
-
-
Replacement of Back oil Seal ,Crank Shaft in existing DEA sets up to 20 KVA Capacity , Replacement of Back oil Seal ,Crank Shaft in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
3
-
-
Labour Charges for Top Overhauling of existing more than 20 KVA and upto 55 KVA Capacity , Labour Charges for Top Overhauling of existing more than 20 KVA and upto 55 KVA Capacity DEA Sets of various Make and Model as per manufacturer recommendations including dismantling of all the filters like oil filters, diesel filter, air filter, tappet setting, cylinder head and cleaning of all carbonised parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safeties, meters if reqd and calibration of engine as per manufacturer recommendations etc as required.
1
-
-
Replacement of Liner assembly with rubber ring in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of Liner assembly with rubber ring in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of Piston Set without Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of Piston Set without Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of Set of Gasket including Head Gasket in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of Set of Gasket including Head Gasket in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of O Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of O Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of CR Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of CR Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of Main Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of Main Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of Oil Pressure Gauge in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of Oil Pressure Gauge in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of Front oil Seal Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of Front oil Seal, Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Replacement of Back oil Seal Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity , Replacement of Back oil Seal, Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.
1
-
-
Repairing of Cylinder Head , One Job for Each Head , Repairing of Cylinder Head , One Job for Each Head, with replacement of valve seat, Valve guide, Valves and stamp seal including grinding , lapping of valves including turning, grinding of head etc complete as reqd.
1
-
-
Repairing of Crank Shaft Up to 20 KVA DEA sets , Repairing of Crank Shaft Up to 20 KVA DEA sets including Grinding , lapping , bushing, alignment etc complete as reqd.
1
-
-
Repairing of Crank Shaft More Than 20 KVA and Upto 55 KVA DEA Sets , Repairing of Crank Shaft More Than 20 KVA and Upto 55 KVA DEA Sets including Grinding , lapping , bushing, alignment etc complete as reqd.
1
-
-
Transportation Charges for Alternator Upto 50 Km of various capacity up to 55 KVA , Transportation Charges for Alternator Upto 50 Km of various capacity up to 55 KVA from Site to the nearest Workshop and back after repairing including Dismantling, loading, unloading, transportation, safe Handling and including reinstallation, making connections, power and control cable connections etc. and testing on existing load for at least one hour after commissioning of the Alternator etc. complete as reqd.
4
-
-
Transportation Charges for Alternator More than 51 to 100 Km of various capacity up to 55 KVA , Transportation Charges for Alternator More than 51 to 100 Km of various capacity up to 55 KVA from Site to the nearest Workshop and back after repairing including Dismantling, loading, unloading, transportation, safe Handling and including reinstallation, making connections, power and control cable connections etc. and testing on existing load for at least one hour after commissioning of the Alternator etc. complete as reqd.
1
-
-
Rewinding of Main Stator winding of Alternator Capacity up to 20 KVA of existing faulty Alternator , Rewinding of Main Stator winding of Alternator Capacity up to 20 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required.
2
-
-
Rewinding of Main Rotor winding of Alternator Capacity up to 20 KVA of existing faulty Alternator , Rewinding of Main Rotor winding of Alternator Capacity up to 20 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required.
2
-
-
Rewinding of Main Stator winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator , Rewinding of Main Stator winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required.
2
-
-
Rewinding of Main Rotor winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator , Rewinding of Main Rotor winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required.
2
-
-
Rewinding of Exciter Stator winding of Alternator Capacity up to 55 KVA of existing faulty Alternator , Rewinding of Exciter Stator winding of Alternator Capacity up to 55 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required.
2
-
-
Rewinding of Exciter Rotor winding of Alternator Capacity up to 55 KVA of existing faulty Alternator , Rewinding of Exciter Rotor winding of Alternator Capacity up to 55 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required.
1
-
-
Replacement or Repairing of faulty AVR for existing faulty Alternator up to 55 KVA Capacity , Replacement or Repairing of faulty AVR for existing faulty Alternator upto 55 KVA Capacity iorc dismantling the faulty item, replacement by new one fixing, testing, commissioning etc. complete as reqd.
4
-
-
Replacement or Repairing of faulty Power Diode for Rotating Rectifier Assembly for existing faulty Alternator up to 55 KVA Capacity , Replacement or Repairing of faulty Power Diode for Rotating Rectifier Assembly for existing faulty Alternator upto 55 KVA Capacity dismantling the faulty item, replacement by new one iorc fixing, testing, commissioning etc. complete as reqd.
3
-
-
Replacement or Repairing of faulty Bearing Suitable for above 20 KVA Alternator up to 55 KVA Capacity , Replacement or Repairing of faulty Bearing Suitable for above 20 KVA Alternator upto 55 KVA Capacity dismantling the faulty item, replacement by new one iorc fixing, testing, commissioning etc. complete as reqd.
5
-
-
Providing of 2 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable , Providing of 2 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable of 1.1 KV grade confirming to relevant IS-Specification complete as reqd. Note Cable shall be provided at Site or Handed over to SSA Authority as per direction of Engg. in Charge
100
-
-
Providing of 4 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable , Providing of 4 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable of 1.1 KV grade confirming to relevant IS-Specification complete as reqd. Note Cable shall be provided at Site or Handed over to SSA Authority as per direction of Engg. in Charge
300
-
-
Laying and fixing on wall Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable , Laying and fixing of Upto 35 sq. mm ,clamped with 1mm thick saddle, one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade of following size on wall surface as required.
100
-
-
Laying of direct in ground Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable , Laying of one number up to 35 sq mm PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
5
-
-
Laying in the existing RCC or HUMEor METAL pipe Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable , Laying of one number up to 35 sq mm PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade in the existing RCCor HUMEor METAL pipe etc. as required.
225
-
-
Supplying and making end termination with brass compression gland and aluminum lugs for 2 X 10 sq. mm , Supplying and making end termination with brass compression gland and aluminum lugs for 2 X 10 sq. mm , 19 mm for PVC insulated and PVC sheathedorXLPE aluminum conductor cable of 1.1 kV grade as required.
8
-
-
Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 16 sq. mm , Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 16 sq. mm , 28 mm for PVC insulated and PVC sheathedorXLPE aluminum conductor cable of 1.1 kV grade as required.
24
-
-
Providing and fixing 6 SWG dia G.I. wire , Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surfaceor recessed conduitorsub main wiringor cable as required.
200
-
-
SITC of 32 amps four pole ON Load Side Handle operated change over switch , SITC of 32 amps four pole ON Load Side Handle operated change over switch in steel enclosure capable of working 415 or 500 V iorc drilling hole on the board, making connection, earthing the body etc. as reqd.
1
-
-
SITC of 63 amps 2 Pole ON Load Side Handle operated change over switch , SITC of 63 amps 2 Pole ON Load Side Handle operated change over switch in steel enclosure capable of working 240 V iorc drilling hole on the board, making connection, earthing the body etc. as reqd.
1
-
-
SITC of 63 amps four pole ON Load Side Handle operated change over switch , SITC of 63 amps four pole ON Load Side Handle operated change over switch in steel enclosure capable of working 415 or 500 V iorc drilling hole on the board, making connection, earthing the body etc. as reqd.
3
-
-
Providing and Fixing 63 A TPN Disconnector Fuse Switch Unit in sheet steel enclosure , Providing and Fixing 63 A TPN Disconnector Fuse Switch Unit in sheet steel enclosure alongwith HRC fuses capable of working 415 or 500 V including drilling hole on the board, making connection, earthing the body etc. as reqd.
2
-
-
Repairing of Fuel Injection Pump , Repairing of Fuel Injection Pump, Nozzle and Injectors including dismantling, transportation of Pump, cleaning, repairing, testing and refitting the same on the existing EA set including replacement of faulty components etc. complete as reqd.
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%