Bharat Sanchar Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 11,918Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/5047920Bid Award Id
ViewTender No
GEM/2024/B/5047920Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
technical_specification_2024-06-13-16-32-19_0f42230dc0ef22a3404e9c305450a7bd.pdf
finalboq_2024-06-13-16-32-19_5327b8792d6f9f6008beea78ec725706.csv
BOQ Items
Replacement of carbon bush set , Replacement of Carbon bush set in the self starter of DEA set i/c connection, testing etc complete as reqd.
1
-
-
Replacement of solenoid coil , Replacement of Solenoid coil in the self starter of DEA set i/c connection, testing etc complete as reqd.
1
-
-
Replacement of Bendex Gear , Replacement of Bendex Gear in the self starter of DEA set i/c connection, testing etc complete as reqd.
1
-
-
Supply and Fixing of 12 volt battery operated self starter , Supply and Fixing of 12 volt battery operated self starter suitable for DEA set including fixing the same on the DG set making connection testing etc complete as required.
2
-
-
Supply and Fixing of 24 volt battery operated self starter , Supply and Fixing of 24 volt battery operated self starter suitable for DEA set including fixing the same on the DG set making connection testing etc complete as required.
2
-
-
Repairing of 12 or 24 volt self starter , Repairing and Servicing of the 12/24 volt battery operated self starter of DEA set i/c dismantling, cleaning of self with petrol, greasing and oiling of bearing i/c testing etc complete as reqd
5
-
-
Repairing of 12 volt battery charging alternator , Repairing and servicing of the 12 volt battery charging alternator for DG set i/c greasing, oiling, making connections testing etc. complete as reqd.
3
-
-
Replacement or supply of battery charger , Replacement/Supply of 12 Volt 10amps Battery Charger SMPS based. In DEA set set I/c fixing , connection,testing etc complete as reqd.
10
-
-
Replacement or supply of hour meter , Replacement/Supply of 12 Volt DC/220 Volt AC hour meter inDEA set set I/c fixing , connection,testing etc complete as reqd.
10
-
-
Replacement or supply of stop solenoid , Replacement/Supply of Stop Solenoid, 12 volt (Engine shut off solenoid) in DEA set set I/c fixing , connection,testing etc complete as reqd.
3
-
-
Replacement or supply of steel wire braided fuel pipe , Replacement/Supply of steel wire braided fuel pipe with benjo bolts & washer in DEA set set I/c fixing , connection,testing etc complete as reqd.
20
-
-
Replacement or supply of battery lead , Replacement/Supply of Battery Lead of suitable size and length with brass terminals set (pair) in DEA set set I/c fixing , connection,testing etc complete as reqd.
5
-
-
Removal of Fan Belt set in the existing DEA set upto 50 KVA , Removal of Fan Belt set in the existing DEA set upto 50 KVA and providing & fixing of new parts to bring the Engine in healthy condition including testing etc. complete as reqd.
5
-
-
Removal of Fuel feed pump kit in the existing DEA set upto 50 KVA , Removal of Fuel feed pump kit upto 50 KVADEA set i/c. testing etc. complete as reqd.
10
-
-
Removal of Radiator hose connections upto 50 KVA DEA set , Removal of Radiator hose connections (Supply and Return) upto 50 KVADEA set i/c. testing etc. complete as reqd.
2
-
-
Repairing of radiator up to 30 KVA DEA set , Repairing & General Servicing of the existing faulty radiator up to 30 KVA DEA set by with help of cleaning agents, Dismantling of radiator assembly including transportation, brazing and testing for leakage and re-installation etc. reqd.
1
-
-
Repairing of radiator above 30 KVA and up to 82.5 KVA DEA set , Repairing & General Servicing of the existing faulty radiator above 30 KVA and up to 82.5 KVADEA set by with help of cleaning agents, Dismantling of radiator assembly including transportation, brazing and testing for leakage and re-installation etc. reqd.
1
-
-
Repairing of radiator above 82.5 KVA and up to 160 KVA DEA set , Repairing & General Servicing of the existing faulty radiator above 82.5 KVA and up to 160 KVA DEA set by with help of cleaning agents, Dismantling of radiator assembly including transportation, brazing and testing for leakage and re-installation etc. reqd.
1
-
-
Supply and Fixing of 63 Amp capacity four pole OFF load change over switch , Supply and Fixing of 63 Amp capacity four pole OFF load change over switch in sheet steel enclosure capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. complete as reqd.
3
-
-
SITC of 63 Amp capacity TPN switch with fuse unit in sheet enclosure , SITC of 63 Amp capacity TPN switch with fuse unit in sheet enclosure capable of working on 415/500V i/c. drilling the hole on the board, making connection,earthing the body etc. complete as reqd.
3
-
-
Supplying and laying 3 core 2.5sqmm PVC insulated and PVC sheathed copper cable , Supplying and laying 3 core 2.5sqmm PVC insulated and PVC sheathed flexible copper cable for charger connection of 1.1 KV grade i/c fixing the same on wall with suitalbe plastic clip etc, as required.
30
-
-
Supplying and laying 2 x 10 Sqmm cable. , Supplying and laying of 2x10 sqmm (on wall /pipe / ground) size of pvc insulated pvc sheathed 1.1 kv grade XLPE Aluminium conductor armoured cable confirming to relevant IS-Specification etc complete as reqd.
50
-
-
Supplying and laying 4 x 16 Sqmm cable. , Supplying and laying of 4x16 sqmm (on wall /pipe / ground) size of pvc insulated pvc sheathed 1.1 kv grade XLPE Aluminium conductor armoured cable confirming to relevant IS-Specification etc complete as reqd.
250
-
-
Repairing of faulty AVR up to 50 KVA Alternator , Replacement / Repairing of faulty AVR (Make National or S.S.)up to 50 KVA Alternator i/c fixing, testing, commissioning etc. complete as reqd.
3
-
-
Repairing of faulty Power Diode up to 50 KVA Alternator , Replacement / Repairing of Power Diode for Rotating Rectifier Assembly i/c fixing, testing, commissioning etc. complete as reqd.
3
-
-
Providing Electrician for attending day to day fault , Providing Electrician as and when required for attending day to day faults / complaints of wiring, fans, electrical supply, DG, AC i/c necessory T&P etc. and related works complete excluding the cost of material etc. as per direction of Engineer-in-Charge.
15
-
-
Dismentalling up to 50 KVA DEA set , Dismentalling of existing up to 50 KVA DEA set at existing TE Buildings / BTS sites with the help of crane/chain pully along with all accessories such as Canopy, fuel tank, silencer, control panel , exhaust piping , cabling, etc. and making good the same etc. complete as required.
2
-
-
Transportaion charges up to 50 KVA DEA set , Transportaion charges of existing up to 50 KVA DEA set at from existing TE Building Store / TE building with all accessories i/c. loading, unloading etc complete as required ( site up to 100 Kms i/c. to and fro distance).
2
-
-
ITC up to 50 KVA DEA set , ITC of existing up to 50 KVA DEA sets along with all accessories with the help of Chain pully/ crane on existing C.C foundation /floor i/c fixing of all accessories and all connections and testing on load etc complete as required.
1
-
-
Extra for shifting or unloading DEA set up to 20KVA , Extra for shifting/unloading of existing DEA set up to 20KVA from roof top of the building to ground floor completely etc as required to shift/ unloading of DG set and re-assembling the same etc complete as required
1
-
-
Extra transportaion charges for DEA set beyond 100 KMs , Extra transportaion charges for DEA set beyond 100 KMs( i/c. to and fro distance) with all aceesories up to the destination etc. as required
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements