Amber Development And Management Authority Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Amber Development And Management Authority - ADMA Tender

Works
Security and Emergency Services
Eprocure
Opening Date22 Sep 2023
Closing Date3 Oct 2023
Tender Amount₹ 44,60,000 
Notes
Download

Costs

  • EMD

    ₹ 89,200
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC of 2 MP 32X Powered by DarkFighter IR Network PTZ Speed Dome Image Sensor 1/2.8" progressive scan CMOS Min. Illumination Color: 0.005 Lux @(F1.6, AGC ON),B/W: 0.001Lux @(F1.6, AGC ON),0 Lux with IR ,Shutter Time 1/1 s to 1/30,000 s,Day & Night IR Cut Filter,32× optical zoom,Digital Zoom 16× ,Focal Length 4.8 mm to 153 mm,24 programmable privacy masks,120 dB WDR,IR Range 150 m ,Movement Range (Pan) 360° endless,Pan Speed Configurable, from 0.1°/s to 160°/s, ,Preset speed: 240°/s ,Movement Range (Tilt) From -15° to 90° (auto-flip) Tilt Speed Configurable, from 0.1°/s to 120°/s,Preset Speed: 200°/s ,Presets 300 ,Power-Off Memory Support,3D Positioning,Face Detection, Intrusion Detection, Line Crossing Detection, Region Entrance Detection, Region Exiting Detection, Object Removal Detection, Unattended Baggage Detection, Audio Exception Detection,Smart Tracking,ANR (Automatic Network Replenishment),HLC/BLC/3D DNR/Defog/EIS/Regional Exposure/Regional Focus,Built-in memory card slot, support Micro SD/SDHC/SDXC, up to 256 GB; NAS (NPS, SMB/ CIPS), Video Compression H.265+/H.265/H.264+/H.264, Alarm Output 1-ch alarm output,Alarm Input 2-ch alarm input Audio Input,1-ch audio input ,Audio Output 1-ch audio output, Network Interface 1 RJ45 10 M/100 M Ethernet, Power 24 VAC and Hi-PoE,Protection Level IP66, IK10,Working Humidity ≤ 90%,Working Temperature -30°C to 65°C (-22°F to 149°F) Certificate CE,FCC,UL,BIS Make- Hikvision/Panasonic/Samsung/Honeywell

4

378000

94500

... More
SITC of 64 Channel Network Recorder Support Up to 64 channel IP cameras can be connected Up to 12 MP high-definition live view, storage and playback Up to 320 Mbps (or 200 Mbps when RAID is enabled) high incoming bandwidth ensures IP cameras can be connected 2 HDMI (different source) and 2 VGA (different source) interfaces 16 HDD ,Capacity Up to 10TB capacity for each HDD, 1 eSATA interface, Supports some specialist cameras, including people counting camera/ANPR (automatic number plate recognition) camera/fisheye camera, Support third party camera, Supports RAID 0, 1, 5, 6, 10 and N+1 hot spare for even more reliable data storage, effectively avoids data loss risk, Decoding Format H.265+, H.265, H.264+, H.264, Synchronous Playback 16-ch, Recording Resolution 12 MP/8 MP/6 MP/5 MP/4MP/3MP/1080p/UXGA/720p/VGA/4CIF/DCIF /2CIF /CIF/QCIF, Network Protocol TCP/IP, DHCP, Hik-Connect, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS,Network Interface 2, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface, Serial Interface RS-232; RS-485; Keyboard,USB Interface Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0,Alarm In/Out 16/4,Power Supply 100 to 240 VAC, Working Temperature -10 °C to 55 °C (14 °F to 131 °F),Working Humidity 10 to 90 %,Chassis 2U Certification :- CE,FCC,UL,BIS Make- Hikvision/Panasonic/Samsung/Honeywell

1

312430

312430

... More
SITC of LED Monitor full HD complying to with following specifications:Resolution : Full HD : 1920 x 1080 or better Backlight : CFL/LED Brightness : 400 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz installation at site with connections and along with all accessories of 55 INCHES sizes etc. comp as required Make- Samsung, Panasonic,Sony, LG

2

150000

75000

... More
Charges of making Jhiri in the wall required for fixing conduit 20mm/25 mm, including covering conduit and making good finish the same as before.The repairing of Jhiri & covering of conduit should be done by lime sand plaster & then applying lime kara as per traditional pratice.

600

63000

105

... More
Removing & refixing the existing floor stone for laying the cable/wire/conuit and making good the same i/c replacement of broken stone complete etc. as required.

210

63000

300

... More
P&F of Point to Point Wireless Radio Link router (PAIR), Superior net throughput – 1.5 GBPS, 25 DBi, Best latency – 3 ms,Configurable channel bandwidth - 3.5-50Mhz, Dynamic Frequency Selection (DFS), AIS (Automatic Interference Sensibility) technology, PPS upto Up to 400,000 Packets Per Second, Power over Ethernet (PoE) - 48 VDC, IP67 operating temprature -5 degree to 55 degree, connector 2x RJ-45, Real time & history - logs and counters of traf c and radio data, 24dBi (integrated). should complete in all respect for mounting, clamp, structure etc. if required. Make Mimosa/Wavesight

1

214571

214571

... More
P & F of HDMI cable 1.4 version Make :-Allen, Terabute, Kramer

2

800

400

... More
SITC of 10Tb Surveillance grade HDD Formatted capacity (512 bytes/sector)** 10,000 GB (10TB),SATA interface transfer rate 600 MB/s,Maximum data transfer rate 185 MB/s,Cache buffer 256MB,Voltage tolerance (including noise) 5V ±5% 12V ±10%,Non-Operating (Ambient °C) –40° to 70°,Relative humidity 5% to 90% (operating) 5% to 95% (non-operating) Approved Make :- Seagate/WD

10

382550

38255

... More
SITC of client server CPU IntelIntel® Core™ i7-8700k @ 3.70 GHz RAM 16 GB HDD SATA-II 7200 RPM Enterprise Class HDD for OS and Enterprise-class HDD or high performance network HDD, It should support 20 MB/s writing and 20 MB/s reading HDD for picture storage At least 650 GB for the HDD where VSM service is installed OS Microsoft® Windows Server 2012 (R2) 64-bit with NVDIA graphics card Make Dell, HP

1

100000

100000

... More
Part B BSR

-

-

-

... More
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

4450

249200

56

... More
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

3250

159250

49

... More
Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6 fiber

1800

255600

142

... More
Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm (OS1/OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2), should have length of min 1.5m, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, Should be delta IL 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirments.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

10

12120

1212

... More
Fiber Fusion Splicing with OTDR Testing of Fiber Single/ Multi mode (per splice) of glass Fiber Optic Cable including cleaning the cable and making splice as per standard practice complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

18

14436

802

... More
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6 Ports

11

74129

6739

... More
Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single Mode Patch Cord 1 Mtr.

15

21255

1417

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity 99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
1.5 Sq. mm

-

-

-

... More
3 core

1450

205900

142

... More
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

12

6960

580

... More
Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) Swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate, The pole shall be made from steel tube & Pipe (IS:1141, Fe 410) including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry with 32 mm dia. 'B' class GI cable sleeves complete as required. of following height & designation. ( See Table P - 02 for specs. ) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
7.5 Mtr. ( 410 SP - 5 )

10

154190

15419

... More
S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
25 mm x 12 mm

1700

85000

50

... More
Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

8

294264

36783

... More
Supply & Installation of IP-20 & IK-08 , UL Listed Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,Vertical Mounting Rail 1.6 MM with 'U'Marking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, Set of 75 mm height 4 castors, 2 of which have brakes, Accessories like: 5 Nos of 19" 1U Horizontal Cable manager, 2 Nos of vertical cable managers, 1 no. Keyboard Tray, 4 Nos of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 2 No of 19" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
22 U Rack with Width 600 mm & Depth 800 mm

1

33069

33069

... More
Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

8

75576

9447

... More
Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6 U Rack with Width 600 mm & Depth 400 mm + 100 mm

8

73384

9173

... More
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

250

33750

135

... More
labour charges for Excavating trenches of required width for pipes dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.:

-

-

-

... More
Ordinary Rocks

380

115900

305



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.