All India Council For Technical Education Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
Refer DocumentsDocument Cost
₹ 500Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_SSAR_209371_4Bid Award Id
ViewTender No
NIT NO.03(CIVIL)/2020-21/UDAIPURTender Authority
All India Council For Technical Education ViewPurchaser Address
-Website
http://https://www.aicte-india.org/reports/overview/Sarva-Shiksha-Abhiyan
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 Grade nominal mix (with graded stone aggregate 20mm nominal size)
0.14
-
4429
Providing and layiny in position pecified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement ; 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15° , landings, balconies , shelves ,chajjas, lintels,bands ,plain window, sills ,staircases and spiral staircases etc.M20 Grade nominal mix (with graded stone aggregate 20mm nominal size)
4.81
-
4909
Random Rubble stone masonary for superstructure above plinth level one storey height above 30 cm. thick walls in : cement sand mortar 1:6 (1-Cement: 6- Sand)
0.43
-
2103
Brick masonary in foundation and plinth with bricks of class designation 75 in Add extra for brick work in superstructure up to third storey in : Cement mortar 1:6 ( 1 cement : 6 coarse sand ) add extra for Square or Rectangular Pillars Up to 45cm length and all sides are free .
0.11
-
3676
Half brick masonry in Superstructure , above plinth level upto floor five level using bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand)Add extra for half brick masonry in superstructure up to third storey including cost of nominal hoop reinforcement ( 2 Nos. 6 mm dia M.S.
bar at every forth course )
0.86
-
381
Centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formworks for foundation in basement rafts, footings, straps beams, bases of columns etc. up to plinth level.
0.59
-
85
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor three level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
20.49
-
184
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Thermo mechanically treated bars (conforming to relevant IS:1786)
564.7
-
67
Grading for roof water proofing treatment with C.C. 1:2:4 with water proofing compound as per manufractures specification
2.06
-
3656
Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design.
0.72
-
30
PLASTER Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick.
373.63
-
99
PLASTER (Ceiling) 6mm thick cement plaster to ceiling of mix 1:3 (1 cement:3 fine sand)
86.2
-
107
PCC : Providing and laying in position cement concrete including curing compaction etc.Complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level using crusher broken aggregate- 1:4:8(1 cement:4 coarse send:8 graded stone aggregate 40mm nominal size.
1.96
-
2758
Polished Blue Kota stone flooring skirting laid over 20mm thick base of CM 1:4 and jointed with gray cement slurry to match the shade of the slab including rubbing and polishing complete For area of each slab From 2001 Sq.cm to 5000 sq.cm 25 mm thick slab
69.09
-
794
Polished Blue Kota stone slab in steps, walls, pillars, having fine machine cut edges laid on 12mm (Av.) thick cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete 25 mm thick slab area 901 to 2000 sq.cm
16.95
-
774
Providing and fixing T-iron frames for doors windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs, 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screw or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
186
-
87
Providing and fixing M.S.steel double leaf shutter in angle iron frame 35x35x5mm suitabily diagonally bracked with 35x3mm flat iron above & below lock rail of size 50x5mm beading extra including all fittings, as per direction of engineer incharge but excluding the cost of chowkhats, including two coats of anti-corrosive red oxide primer paint. M.S. sheet 20 S.W.G.
10.87
-
1826.4
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20 x 3 mm with suitable screw at not exceeding 150mm distance.
9.14
-
455
Providing and fixing square bars or other flat welded to window ventilators etc. 12 mm square bars.
81.36
-
66
PANTING ON DOORS & WINDOWS
Painting with enamel paint of approved brand and manufacture in all shade to give an even shade : Two or more coats on new work.
40.19
-
66.3
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade two or more coats on new work including prepration of base with primer putty lippy complete in all respect
393.59
-
62.5
Providing and applying Birla/JK white cement based putty over cement plaster surface for making even surface.
479.79
-
115
Copping: Providing and laying cement concrete including curingcompaction etc. complete in retaining walls, return, walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses string or lacing courses, parapets coping bed blocks anchor blocks plain windows sills, fillets etc. up to floor three level excluding the cost of centering and shuttering.M15 grade Nominal Mix ( with graded stone aggregate 20mm nominal size)
0.64
-
3700
Supply & Stacking good earth at site complete including loading unloading & transportation etc.
10.33
-
110
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
10.33
-
52
Brick masonary in foundation and plinth with bricks of class designation 75 in Add extra for brick work in super structure up to third storey : cement mortor 1:6 (1 cement: 6 coarse send).
5.64
-
3360
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia
6
-
179
Part (B) Electrical Work Based on PWD BSR 2013 For Jaipur Circle
-
-
-
Wiring of light point/exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make Short point (up to 3 mtr.)
4
-
172
Medium point (up to 6 mtr)
4
-
270.4
Long point (up to 10 mtr)
8
-
379.2
Wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make in surface/reces gp-2 On board
2
-
72
S & F follwing sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface/ recessed using clamps, fastener as required according cutting the wall and making good the same as required. Group-2 25 mm dia For light circuit
1.05
-
33.6
Supplying and drawi;ng FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. Group-2 2 x 1.5 sq. mm
60
-
22.1
2 x 2.5 sq. mm
30
-
34.9
6 A to 32 A rating
1
-
114
P & F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with 100 Amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to IS 13032 & IS 8623 including Single door 8 way for first floor circuit control
1
-
510
P & F strip fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating/stove enamelled non corrosive UV resist EP channel) complete with accessories(Low loss copperchoke, starter, starter seat)/Electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(Without tube) 1x36 watts with OCCB. Group-2
6
-
315.2
P & F Fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts
6
-
50.4
P & F star rated double ball beari;ng capacitor start, aluminium body and blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required. Grope -01 1200 mm sweep
6
-
1451
P/I aying PVC insulated & PVC sheathed cable of 1.1 kV grade with aluminium conductor of IS:1554 P-I of Groups of approved make in ground as per IS:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, Iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm
30
-
146
P & F IS:371 marked 6 amp sufface type celling rose inculuding making commection testing etc. grup-2 (E071400)
6
-
14.4
P & F 18 SWG Sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175mmX 100mmX60mm (E050100)
2
-
57
P & F ISI marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required
3
-
16
S&F of power plug point accessories on 18 SWG metal box of size 175X100X60 mm on surface or in recessed with suitable size phenolic laminated sheet cover inculeding cost of 6 pin 16 amp.switch and socket outlet,making connection testing atc as required Grope-01
10
-
235
P&F socket size flush tipe 120/280 watt rotary 5 step fan regulator including making connection testing etc ac required Group-1
6
-
210
P&F 240/415 V isolator confirming to IS:13947-III/IEC 60947-3 on existing board/ sheet includingh making connection testing etc.as required. 30A/40A rating.Group-1
1
-
298
Pipe Earthing as per lS:3043 with perforated 3.00 mtr. long 40 mm dia. B class G.I. pipe including all accessories like nut' bolts' reducer ,nipple, wire meshed funnel'6nd C'C' finished chamtler covered with hinged type with locking arrangement C'l' Cover, C'l' Frame of size300mm x300mm and embodying the pipe complete with alternate layers of salt and oke/charcoal, testing of earth resistance as required'
1
-
1650