Ajmer Development Authority Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Ajmer Development Authority - ADA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date28 Jun 2022
Closing Date18 Jul 2022
Tender Amount₹ 22,03,00,000 
Notes
Download

Costs

  • EMD

    ₹ 44,06,000
  • Document Cost

    ₹ 10,000
  • Tender Fee

    ₹ 1,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in All kinds of soil ( Lift 1.50 - 3M)

1257

-

31

... More
Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in Ordinary Rock (Lift 1.5 - 3.0 m)

375

-

55

... More
Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand

1228

-

931

... More
Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion)

1720

-

43

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20%

430

-

211

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

951.24

-

3664

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).

27.17

-

4362

... More
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by using min 410 kg of cement per cum .

1257

-

4583

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by using min 410 kg of cement per cum .

639

-

4955

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix

27

-

4939

... More
Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge . All works upto floor V floor. M25 grade Design Mix by using min 410 kg of cement per cum

1942

-

5765

... More
Providing and fixing 50mm thick cement concrete flooring with Metallic concrete hardener topping, under layer of 38mm thick cement concrete 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm thick nominal size) and top layer of 12mm thick metallic concrete hardener consisting of mix 1:2 (1 cement : 2 stone aggregate, 6mm nominal size) by volume & mixed with metallic hardening compound of approved quality @ 2Kg./Sqm including cement slurry, rounding off edges etc. but excluding the cost of nosing of step etc. complete.

1735

-

432

... More
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.

1443.02

-

150

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : :Walls (any thickness) including attached pilasters, buttresses plinth and string course.

5384.02

-

276

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.

14219.24

-

324

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : :Columns, pillars, posts and struts etc.

3619

-

357

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code)

579433.66

-

67

... More
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide

8425

-

87

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

3812

-

463

... More
Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes.

29425

-

91

... More
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand)

59

-

4068

... More
Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 4 (1 cement : 4 coarse sand)

981

-

4688

... More
Providing & Laying autoclave aerated blocks masonry with 150mm/230mm/300mm thick AAC Blocks of Grade-I Conforming to IS:2185 Part:III in superstructure above plinth level with polymer modified adhesive mortar as per direction of Engineer in Charge.

805

-

4380

... More
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 12mm thick .

8328

-

167

... More
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 20mm thick .

3734

-

188

... More
6 mm thick cement plaster to ceiling of mix 1:3 (1cement 3-fine sand)

8179

-

126

... More
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats)

11462

-

80

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.

15109

-

77

... More
Providing and applying superior quality wall painting with Velvet touch emulsion paint of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of Engineer-in-charge. New Work Three or More coat

1147

-

224

... More
Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ).

1232

-

82

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : :Two or more coats on new work

2379

-

66

... More
Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10m height with 20 to 30 mm thick Red Sand Stone (Karauli ) and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing by means of cramps which shall be paid separately) Exposed face machine cut

1379

-

2273

... More
Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10 m height with 20 to 30 mm thick Pink Sand stone (Bansi Paharpur) and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid separately) Exposed face Machine cut

2212

-

2305

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases in stone and holes in walls wherever required

5321

-

643

... More
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases.

26597

-

24

... More
Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of.

4788

-

58

... More
Supplying and fixing machine cut fine dressed Red/Pink sand stone dasa or coping, with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 50 mm thick

194

-

1325

... More
P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm

4914

-

1047

... More
P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm

90

-

1178

... More
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).

347

-

714

... More
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :For area of each slab from 2001 to 5000 Sq.Cm

622

-

974

... More
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001 Sqcm

226

-

869

... More
Providing and fixing 1st quality MAT & GLOSSY finished ceramic tile confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). Size 300mm x 450mm

1034

-

771

... More
Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs

661

-

2890

... More
Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-inCharge. Granite/Kota Stone Work Full Edge moulding

734

-

222

... More
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete

92

-

23

... More
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete

48

-

244

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge).

97

-

5518

... More
Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E

1215

-

448

... More
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : 35 mm thick . Commercial Veneer both side

469

-

1738

... More
Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge. 0.8mm thick mica

985

-

705

... More
Providing and fixing of openable uPVC Doors with or without fix top: Frame Made of Extruded uPVC Window Profile Section of size 60w x 70h mm having outer wall thickness of 2.75mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick GI section. All the corners shall be mitered cut & thermal welded so as to form door frame. Fix Mullion made of 60w x 80h mm uPVC Profile Section with steel reinforcement shall be provided for the top fix portion of the doors or in case of the doors having more than two openable shutters, as per the requirement / drawing. Frame of openable door shall have „O‟ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutters of openable door shall be made of 60w x 95h mm Extruded 3 box multi-chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.75mm (+/- 0.2mm) provided with reinforcement of 2.0 mm thick GI section duly mitered cut & thermal welded at all corners, provided with center mullion (if specified in drawing) of size 60w x 80h mm uPVC Profile Section and fitted with uPVC glazing bead of size 36 x 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass.

70

-

9930

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. :With stainless steel cover plate

137

-

1360

... More
Extra for providing frosted glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).

17

-

144

... More
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.

100

-

312

... More
Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminium

32

-

69

... More
Providing and fixing vertical Blinds , headrail shall be oriented aluminum alloy 50 mm wide x 18 mm high the thickness shall be 1.2 mm. Control unit shall be made of high grade polymer and shall be housed in side the headrail, which shall transfer motion from chain tilter to tilt rod. Chain tilter shall be made of plastic bead of diameter 4.5 mm through which 2 mm thick polyester code passes. Tilt rod shall be extruded aluminum having 3 key ways. Runner shall be moulded plastic and shall have to plastic wheels mounted on plastic exles to enable runner to slide unhindered in headrail. Luver shall be made of fabric 100 mm colour fast and shall have protective scotchgard coating to resist stains and dust. Bottom mechanism consist bottom weight made of powder coated galvanized steel for maximum corrosion resistance. The bottom weight shall be attached with bottom.

903

-

1484

... More
Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge.

29

-

4884

... More
Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass.

725

-

6343

... More
Providing and fixing of UPVC casement openable windows (outward / inward): Outer Frame made from the Extruded UPVC Windows profile section of size 60w X 60h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and three chamber constuction, White in finish, duly reinforced with 1.5mm thick GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 60w X 80h mm UPVC profile section with steel reinforcement shall be provided in windows having 2 or more openable shutters, as per the requirement. Frame shall have co-extruded with EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter: The shutter of outward openable window shall be made of size 60w X 74h mm and shutter of inward openable window shall be made of size 60w x 77h mm Extruded 3 box multi-chamber UPVC Window profile section of white colour having outer wall thickness of 2.25mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with UPVC glazing bead of size 36 X 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gasket alongwith 6mm thick ISI make plain float glass. All welding joints of frame and shutter shall be cleaned and milled with the CNC mechainism to provide uniform grooved finish on all visible jaints. Hardware: Window shutter are fixed with frame on 2.5mm thick SS301 Grade friction hinge system to keep the window opened at desird angle. Friction Hinge also enables easy cleaning of glass on both side from the inside of building.

181

-

9118

... More
Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately)

-

-

-

... More
For fixed portion Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron)

3780

-

332

... More
For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron)

1512

-

360

... More
Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) With float glass panes of 8 mm thickness

630

-

1179

... More
Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting.

716

-

787

... More
Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge.

2670

-

1303

... More
Providing and fixing Hollow core partition wall using 50x30 mm Chir wood frame 600 mm c/c on both directions,door opening as per drawing with steel fittings antitermite treatment complete as per specifications using : ISI 4 mm thick commercial ply with 0.80 mm mica with adhesive on both sides.

483

-

1858

... More
Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

89

-

4278

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :

350

-

106

... More
Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete.

34

-

147

... More
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.)

232

-

1965

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils

1262.51

-

196

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by using min 410 kg of cement per cum .

388

-

4955

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. Design Mix M25 grade Design Mix by using min 410 kg of cement per cum .

51

-

4999

... More
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:4 ( 1-Cement : 4-Sand).

152

-

2893

... More
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 12mm thick .

727.55

-

156

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: :New work (two or more coats) over and including scrapping and priming coat with cement primer.

46

-

71

... More
Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category „B‟ Denated only two side like I,Z,T shape etc. as per IRC SP 63:2004

710

-

983

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-30, over a prepared sub-base with 43 grade cement @ 400 Kg per cum, coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrance, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing complete as per MoRTH specification clause 602.

468

-

3949

... More
Providing and fixing of speed breakers made of abs poly carbonate alloy yellow & black made individually size 500x400x50 mm with two side reflectors of yellow colour 6 nos suitable holes provided on it for fixing it on road with the help of MS nails with three abtes locking arrangement on side of the speed breaker. It is to be fixed on road after cement concrete on the hollow blocks provided in the bottom.

61

-

2915

... More
Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 200 mm Dia nominal bore

100

-

908

... More
Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work. 200 mm Nominal bore of pipe

5

-

1571

... More
S & F tube well cover of M.S.sheet (6mm thick) with nuts and bolts complete for casing size: 200mm dia

1

-

339

... More
Providing & Fixing of Single Stage, water cooled, High Speed(2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal - T/C Vs T/C, Thrust bearing shall be of carbon + S.S.The stator body of single phase pump shall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electro deposition (CED) coated and other construction material should be confirming to IS : 14220: 2018 . The overall performance of pump shall confirm to BEE energy efficiency level of 3 star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011, including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 10.0 HP, 3-Ø, (22 -36) Mtr, (1860 - 1020) LPM

1

-

29932

... More
Supply Installation testing & Commissioning of ISO certified company made DOL/Star- Delta Starter panel made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of overload protection relay, short circuit & single phasing protection, Illuminated ON/OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. Appropriate type test certificate /OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products /work, refer Annexure "A" attached with this BSR For Three phase Submersible / Mono block pump 3.0 HP to 10.0 HP ( Star / Delta starter )

1

-

6614

... More
Supplying and Laying ISI marked P.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS8130:2013 of 1.1kV grade. Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC60228 for lower watt loss, oxygen free (10ppm) for less chances of oxidization and higher silver content for gives better conductivity, insulation PVC typeA, flame retardant as per IS10810-53, better amper agerating as per VDE0298 part4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per preapproved by Engineer in charge, making connections. For additional technical parameters of products/ work, refer Annexure"A" attached with this BSR . 6.0 Sq.mm 3 core flat / Round

70

-

184

... More
Providing & Laying P.V.C./XLPE insulated & P.V.C. sheathed Unarmoured/ Armoured copper cable of 1.1KV grade as per PWD specification for electrical Works in existing RCC/ Hume/ Stoneware /PVC pipe/ open duct/ cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c),mentioned below:- (a) Copper conductor of electrlytic grade copper, purity99.97% ISI marked as per IS:1554P-I/IS:7098 P - I (b) conductor shall mad of copper rods confirming to IS613-1964,IS3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO9001&14001 certifications & its own in house NABL lab setup for all testing facilities for cables. Appropriate type test certificate /OEM test report shall be submitted. All above as per preapproved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR . Armoured 10 Sq. mm 4 Core

100

-

389

... More
Providing & Fixing of HDPE pipe ISI mark (IS:4984/2016) for water supply (suitable for submersible & jet pump) with required fittings ie socket, elbows, tee etc. complete in all respect. Al las per preapproved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . for vertical installation 50 mm OD 6 kg / cm2

50

-

95

... More
P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality: 50mm nominal bore. Vertical

1

-

876

... More
Supplying and stacking good earth at site of work. Note: 1) Loading, unloading and carriage to be paid extra as per actual lead. 2) Earth measured in stacks will be reduced by 20% foe payment

634

-

299.5

... More
Supplying sludge duly stacked at site/ store.

159

-

121.5

... More
Grassing with 'Carpet' grass (selection no. 1) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed.(The good earth shall be paid separately) With grass Turf

2112

-

1049

... More
Maintenance of lawns or Turfing of slopes (rough grassing) for a period of one year including watering etc.

2112

-

194

... More
Digging holes in all kinds of soil and refilling the same with the eaxcavated earth mixed with well decayed farm yard manure (cost of well decayed farm yard manure to be paid separately).

-

-

-

... More
Hole 1.2 m dia and 1.2 m deep

90

-

36

... More
Hole 0.6 m dia and 0.6 m deep

155

-

14

... More
Planting permanent hedges including digging of trenches 60cm wide and 45cm deep refilling the excavated earth mixed with farm yard manure supplied at the rate of 4.65 cum per 1 metres and suppling and planting hedge plants at 30 cm apart.

269

-

27

... More
Maintaining the hedges for the first year including watering etc. complete.

269

-

49

... More
Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.

-

-

-

... More
Ficus panda (12,10, 9)

20

-

676

... More
Tecoma capensis ( Ratanjot)

25

-

502

... More
Clerodendron inermii ( Choti Aari)

50

-

502

... More
Tabernaemontana variegated ( Chandni)

30

-

502

... More
Hamelia patens ( Firebush, Thal Kamal)

20

-

467.5

... More
Hibiscus variegated ( Guddal)

10

-

481.5

... More
Supply and planting following species best quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.

-

-

-

... More
Plumeria alba ( Champa)

15

-

1433

... More
Gulmohar(Delonix regia)

20

-

1247

... More
Jacaranda mimosifolia (Neelli Gulmohar)

25

-

1057

... More
Bauhinia blakeana (Arckid)

30

-

1084

... More
P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: W.C. pan of size 580x440mm

10

-

2273

... More
P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS : 7231 .

10

-

1075

... More
P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor.

46

-

8910

... More
P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall.: Size 610 mm x 510 mm

55

-

2897

... More
P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. other Sizes

15

-

1182

... More
P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor: 1.0 mm thick Salem stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling. Over all siZe (inches) 24 x 18 x 8 Bowl size (inches) 20 x 16 x 8

10

-

4218

... More
P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back Large or Half stall size 610 x 400 x 80mm

19

-

3526

... More
P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble.

13

-

774

... More
P & F C.P. brass Urinal Flush Pipe set complete with flanged brackets of approved make.

-

-

-

... More
For 3 Uninal

6

-

1005

... More
For 1 Urinal

1

-

475

... More
P & F 15 mm. Dia Connection Pipe of approved quality/make : PVC pipe with C.P. Brass nuts upto length, 450 mm

155

-

101

... More
P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-inCharge

46

-

605

... More
Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge

-

-

-

... More
Two way Bib Cock 15 mm nominal size

56

-

1067

... More
Long body Bib Cock 15 mm nominal size

15

-

985

... More
P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked)

155

-

481

... More
P & F Mixing Range (15mm) C.P. wall mixer telephonic type crutch & telephonic shower.

5

-

2890

... More
Providing & Fixing Premium quality Bottle trap internal portion 32mm, size 250mm long wall connection pipe & wall flange as per approved by Engineer in Charge.

55

-

1454

... More
P & F Liquid Soap Container with brackets complete of approved make: C.P. brass

43

-

176

... More
P & F Towel Rail or Ring of approved quality/make: C.P. brass Towel Rail elbow type with concealed screws size 450mm (Heavy duty).

43

-

374

... More
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make

-

-

-

... More
75 mm dia

455

-

139

... More
110 mm dia

664

-

278

... More
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make

-

-

-

... More
Coupler

-

-

-

... More
75mm dia

150

-

55

... More
110mm dia

220

-

83

... More
Bend 87.5 Dg.

-

-

-

... More
75mm dia

50

-

72

... More
110mm dia

90

-

119

... More
Double 'Y' with Door

-

-

-

... More
75mm dia

50

-

228

... More
110mm dia

50

-

349

... More
Pipe Clip

-

-

-

... More
75mm dia

110

-

14

... More
110mm dia

310

-

23

... More
Vent Cowel

-

-

-

10

-

37

... More
110mm dia

10

-

45

... More
Bend 45 Dg. 110mm dia

40

-

101

... More
Door Bend 87.5 Dg. 110mm dia

40

-

147

... More
Single 'Y' 110mm dia

40

-

212

... More
Single 'Y' with Door 110mm dia

40

-

265

... More
Providing & fixing Hubless Spun –Centrifugally cast Iron Pipes (IS : 15905 Mark ) of Approved make in wall or in floor with M.S. Holder bat clamps in 10 X 10 X10 Cm. M-15 Grade concrete blocks, joints filled with CM 1:4 with spun yarn including cutting holes and making good the wall:- 150 mm

100

-

2036

... More
P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: Concealed pipe in wall including painting with anticorrosive bitumen paint. Internal work - ( for wash basin waste ) 32mm dia nominal bore B Class

110

-

378

... More
Providing & fixing Hubless Spun –Centrifugally cast Iron Pipes fitting (IS : 15905 Mark ) in CM 1:4 with spun Yarn. 150mm W/o door Shielded (SS) Coupling (With EPDM Rubber)

34

-

639

... More
P & F Sand-cast Iron (S.C.I.) Pipe (IS : 1729mark) of approved make in wall or in floor with M.S. holder bat clamps in 10 X 10 X 10 Cm. M-15 grade concrete blocks, joints filled with CM 1:4 with spun yarn including cutting holes and making good the wall:

-

-

-

... More
100mm dia

151.67

-

966

... More
75mm dia

154.67

-

792

... More
Providing & fixing Hubless Spun –Centrifugally cast Iron Pipes fitting (IS: 15905 Mark) in CM 1:4 with spun Yarn

-

-

-

... More
100mm W/o door

-

-

-

... More
Ofset (130mm)

70

-

709

... More
D/Door Y-Tee

75

-

1000

50

-

388

10

-

449

... More
75mm w/o door

-

-

-

... More
Offset (130mm)

70

-

511

... More
D/Door Y-Tee

21

-

543

25

-

273

10

-

348

... More
100mm with door

-

-

-

36

-

593

... More
b) 75mm with Door Bend

17.04

-

371

... More
Construction of Cement Concrete Chamber 125mm dia. Stainless steel sheet Grating

95

-

135

... More
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 mm diameter S.W. pipe

20

-

603

... More
P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia.

22

-

49

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)

-

-

-

... More
20mm dia nominal outer dia pipes

675

-

222

... More
25mm dia nominal outer dia pipes

540

-

270

... More
32mm dia nominal outer dia pipes

444

-

341

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)

-

-

-

... More
20mm outer dia pipes

60

-

170

... More
25mm outer dia pipes

250

-

216

... More
32mm outer dia pipes

70

-

283

... More
40mm outer dia pipes

50

-

399

... More
50mm outer dia pipes

150

-

606

... More
Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :

-

-

-

... More
20mm dia nominal bore

102

-

127

... More
25mm dia nominal bore

81

-

149

... More
32mm dia nominal bore

67

-

220

... More
40mm dia nominal bore

40

-

278

... More
50mm dia nominal bore

20

-

421

... More
P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:

-

-

-

... More
25mm horizontal

10

-

451

... More
32mm horizontal

10

-

634

... More
40mm horizontal

10

-

882

... More
50mm horizontal

10

-

1287

... More
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gunmetal 25mm nominal bore.

30

-

481

... More
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity.

1

-

6480

... More
Earth work for Sewer line and Manhole in excavation in foundation, trenches manholes, road side chambers etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level including allowances for any additional excavation beyond the drawings (measurement for payment to be as per standard drawings), re-handling of material/earth to complete the task. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m

456

-

274.5

... More
Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP2 class (with s/s ends IS: 458 - 1988 (amended up to date) marked and manufactured through spun process at all levels with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as directed by Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers, Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.

-

-

-

... More
150 mm internal diameter

100

-

436.5

... More
200 mm internal diameter

220

-

635

... More
250 mm. nominal dia.

230

-

646

... More
Providing granular bedding having width = outer dia of pipe (Bc) + 500mm, thickness below pipe = 0.25Bc or 100mm (whichever is higher) and haunching = 0.5Bc, with graded hard crusher broken stone of 100% passing through 20mm sheive, 20 to 50 % passing through 10mm sheive and 100 % retain on 6.3mm sheive, laying in layers of thickness 10/15cm including ramming, consolidation etc complete for all type of pipes of following sizes as per drawing and or as directed by Engineer.

-

-

-

... More
150 mm internal diameter

15

-

137

... More
200 mm internal diameter

60

-

158

... More
Providing and constructing of SEWER-BRICK (As per IS-4885 amended upto date) masonry circular manholes of "Type-A" with internal dia 0.90m and depth upto 1.65m having 230mm thick sewer brick masonry wall in cement sand mortar 1:4, including concreting PCC M-10 grade (1:4:8) for 225mm thick foundation including curing compaction and form work etc complete, PCC M15 for benching and channel portion, RCC M20 for 200mm thick cover slab including reinforcement, PCC M20 for fixing the manhole frame and cover using stone aggregate 20mm nominal size, 20mm thick inside and outside plaster in C. M. 1:3, inside plaster finished with floating coat of neat cement, vata in CM1:1 around pipe entering and leaving the manhole and also at the junction of masonry and concrete slab, providing and fixing of SFRC foot steps of approved make at every 0.30m height fixed in CM 1:3, supplying and fixing heavy duty SFRC manhole frame and cover as per IS 12592 (Part I and II) having clear opening of 560mm, including refilling of Jhiri, including curing, watering, ramming, hydro testing of manhole, conveyance & cost of water, and dewatering complete as directed by the Engineer. Note:- Excavation of earth work and road cutting for manhole will be measured and paid separately. Manhole Type A of depth 0.90m

7

-

14250

... More
Providing and constructing of SEWER-BRICK (As per IS-4885 amended upto date) masonry circular manholes of "Type-B" with internal dia 1.20m and depth upto 2.50m having sewer brick masonry wall 230mm thick upto 1.5m, 345mm thick from 1.50m to 2.50m in cement sand mortar 1:4, including concreting PCC M-10 grade (1:4:8) for 225mm thick foundation including curing compaction and form work etc complete, PCC M15 for benching and channel portion, RCC M20 for 200mm thick cover slab including reinforcement, PCC M20 for fixing the manhole frame and cover using stone aggregate 20mm nominal size, 20mm thick inside and outside plaster in C. M. 1:3, inside plaster finished with floating coat of neat cement, vata in CM1:1 around pipe entering and leaving the manhole and also at the junction of masonry and concrete slab, providing and fixing of SFRC foot steps of approved make at every 0.30m height fixed in CM 1:3, supplying and fixing heavy duty SFRC manhole frame and cover as per IS 12592 (Part I and II) having clear opening of 560mm, including refilling of Jhiri, including curing, watering, ramming, hydro testing of manhole, conveyance & cost of water, and dewatering complete as directed by the Engineer. Note:- Excavation of earth work and road cutting for manhole will be measured and paid separately. Manhole "Type-B" of depth 1.70 m

12

-

28900

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design

-

-

-

... More
150 mm. dia.

50

-

464.5

... More
250 mm. dia.

200

-

636

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design : With Bricks

4

-

4385

... More
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : With Bricks

10

-

8300

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
25 MM OUTER DIA

30

-

307.5

... More
62.5 mm OUTER DIA

80

-

1867

... More
75 mm OUTER DIA

250

-

2386

... More
Providing and Fixing gun metal valve with C.I. wheel of approved quality(Screwed end):

-

-

-

... More
25mm nominal Bore

10

-

551

... More
65mm nominal Bore

4

-

3990

... More
80mm nominal Bore

4

-

8410

... More
Providing, lowering, laying, aligning, fixing in position and jointing in pipe line CI Kinetic Double Air Valves as per IS:14845 of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. a) 80mm dia

2

-

9960

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casting pumps with motor as per IS 12615-2011 or amended up to date, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification Discharge 181 to 200 LPS and head 41 to 50 M

2

-

495000

... More
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix

14.02

-

4523

... More
P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: Exposed on walls 65mm dia(A Class)

20

-

638

... More
Supply Installation testing & Commissioning of ISO certified manufacturer made Dewatering Submersible Motor Pump set, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. with SS Impellor, body, shaft, mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
1.0 HP, 3-Ø, (5 - 12)Mtr, (333 - 95) LPM

4

-

25958

... More
2.0 HP, 3-Ø, (5 - 18)Mtr, (480 - 66) LPM

8

-

30647

... More
RUIDP Tecknology - Design, supply, erection, installation, jointing, testing, trial run, and commissioning of prefabricated micro Sewage Treatment Plants based on RUIDP Technology for Inlet parameter (Ph-6.5-7.5; BOD5 @ 20 degree C-300 mg/l; COD-650 mg/l; TSS600 mg/l; TKN-55 mg/l) and outlet parameter (Ph-6.5-9.0; BOD5 @ 20 degree C 10 mg/l; COD-= 50 mg/l; TSS- =20 mg/l; N-Total- =10 mg/l & Faecal Colliform-100 MPN/100 ml)complete in all respects. STP will have following components:-

-

-

-

... More
Pretreatment Unit:- Design, Supply, Fabrication of Coarse Screen with Grit Separator Unit. The fine screen (2 Nos.; 1 W+1S) installed in sequence shall be made in SS316L using flat bars of 3 mm thick, 50 mm wide and spacing of 5 mm, tear shape and dimensions of the bar screen as per design approved by engineer. The grit and oil filter separation unit shall be also provided in SS 316 L with interconnecting pipeline made in 90 mm HDPE PE-100 PN-6 as per IS 14333 (amended up to date), necessary fittings while maintaining the hydraulic levels with capacity of removing grease, oil and grit particles having specific gravity 2.85 with removal efficiency of 80%.Prefabricated sump with non clog sewage submersible pump set 1 W +1S of 2% Ni CI Cascading, Impeller CF 8M ,Shaft SS 410,mechanical seal with 10M Power & Control cable , 5M Galvanized Chain,,10M, 50mm MS galvanized Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. installed after the oil and grease chamber. Adequate arrangements shall be made for access to remove the screened waste and settled grit on manual basis.

-

-

-

... More
Primary Settling Tank Unit:- Design, Supply, Fabrication of Primary Settling Tank in Mild Steel of 2-4 mm thickness with FRP coating from inside and epoxy corrosion resistance paint on the outer surface having dimensions as per approved design and drawing by engineer. Necessary support elements shall be provided inside the Primary Settling Tank at a depth of 700mm(minimum) from the top and further down minimum depth of 1.250 m (0.50 m free board extra) for support of the Tube Deck Media. A conical section with adequate slope (1: 12) for sludge to settle and flow down into the sludge storage tank shall be provided. The construction shall be as per the provided drawing. Safety Rails shall also be provided around the top of the tank in 2 rows connected with vertical poles of 1.2 m height at 1.2 m distance apart of Aluminium pipe of 32 NB with odular fittings. A partition shall be provided after the Tube Deck media for collection of clarified effluent which shall be collected while flowing in upward direction. Including GST, Taxes and duties and erection at site.

-

-

-

... More
Secondary-cum-Biological Treatment Unit:- Design, Supply, Fabrication of Secondary cum Biological Treatment Unit in Mild Steel of 2-4 mm Thickness with FRP coating from inside and epoxy corrosion resistance paint on the outer surface having dimensions as per approved design drawing by employer with 3 vertical partitions (minimum) at equal spacing for a minimum length of 3.0 m. The depth of the partitions shall be minimum 1.250 m (0.50 m free board extra) from the vertical. The bottom of the unit shall be conical in shape for sludge collection , fraction of which shall be recycled back into the top most zone of the unit. The construction shall be as per the provided drawing. Safety Rails shall also be provided around the top of the tank in 2 rows connected with vertical poles of 1.2 m height at 1.2 m distance apart of Aluminium pipe of 32 NB with modular fittings. The outlet portion shall be meant for overflow with a depth of 0.50m from the Top water level as provided in the section drawing.

-

-

-

... More
Tertiary Treatment Unit:- Design, Supply, Fabrication of Tertiary Treatment Unit Mild Steel of 2-4 mm Thickness with FRP coating from inside and epoxy corrosion resistance paint on the outer surface having dimensions with circumference around the Primary and Secondary Treatment Units , width of 1 m (minimum) and depth of 1.5 m (minimum). The tank shall have partitions opening from top and bottom in alternate arrangement to provide sinusoidal flow. A drain valve arrangement shall be provided to collect the wash out sludge during any maintenance event.

-

-

-

... More
Filter Media:- Filter media of required distribution and proportion to be filled in the Tertiary Treatment Unit (Qty of 100 mcube or as per deign requirement to fill to the top water level) , required hydrophytic plantation & impregnating inside the Tertiary Treatment Filter Bed.( Qty: 200 Nos of Umbrella Palm & Caina Indica) Bio consortium media comprising of Bacillus sp, bacteriofaciens sp, Phosphatidis sp, Nitrobacter sp, and other Nutrient removing species in wetland systems. (Qty of 100 liters)

-

-

-

... More
Solar Power System:- Supply, Fabrication, Installation, Testing and Commissioning of Solar Power Unit MNRE approved of required capacity including allelectrical, peripheral and mounting accessories. H) Sludge Storage tank:- Sludge storage tanks for primary and secondary sludge with a capacity of 2000 Liters as per the levels provided in the reference drawing, this sludge tank will be connected to the primary settling tank and secondary treatment unit bottom with 110 mm HDPE PE 100 PN-6 pipe with fillings as per IS 14333 (amended up to date). Manually operated butterfly valve of 100 mm dia shall be installed on both coming pipes to regulate the sludge flow.

-

-

-

... More
Sludge Storage tank:- Sludge storage tanks for primary and secondary sludge with a capacity of 2000 Liters as per the levels provided in the reference drawing, this sludge tank will be connected to the primary settling tank and secondary treatment unit bottom with 110 mm HDPE PE 100 PN-6 pipe with fillings as per IS 14333 (amended up to date). Manually operated butterfly valve of 100 mm dia shall be installed on both coming pipes to regulate the sludge flow.

-

-

-

... More
RUIDP Technology component:- Supply, Administering, Installation and commissioning of only the Technology Components for :

-

-

-

... More
1. Primary Settling Tank :- Macroporous Hydrogel constituting of polymers like Polyacrylamide gel - cross linking polymer of Water Insoluble entities with a life span of at least 5 years , impregnated and immobilized with acid resistant Methanation Bacteria like Methanosarcina sp on to the water flowing surface using synthetic adhesives. The system shall be capable for easy installation and maintenance.

-

-

-

... More
2. Secondary Treatment Unit:- Floating rafts of appropriate size as per the provided drawing made of natural materials like bamboo or buoyant material with hydrophytic plantation on top to be installed in the upper most layer of the unit.

-

-

-

... More
Middle Layer comprising of non-organic media support immobilized with aerobic bacteria. The media for support shall be alumina or ceramic based of cylindrical or spherical shapes with minimum 50% porosity to allow favorable bacteria for immobilization and colony formation. Total Depth of the middle layer shall be 925 mm with percentage fill of the media ranging between 35-50% depending on the hydraulic conductivity of the packed bed media column to cater to the peak flow. The average mean diameter of the media elements shall range between 5- 20 mm.

-

-

-

... More
Bottom Most Layer: comprising of thermosetting resin polymer media with infinitesimal shape and protected surface area of not less than 900 m2/m3. Minimum % fill of 35% and the Middle and Bottom layer shall be separated using retractable strainers made in UPVC or FRP lined MS grating for providing support for middle layer media , the same support shall be provided for the bottom most layer.

-

-

-

... More
Manual Micro screen 1 mm 1W +1S in SS-316 at the outlet of secondary unit"

-

-

-

... More
Other Ancillary works - Boundary wall with gate of premises - wall height shall be 1.5 m from FGL. Foundation of boundary wall shall be 1.20 m below natural ground level. Construction up to plinth level shall be in RR masonry in 1:6 cement mortar with 100 mm thick PCC in 1:4:8 below masonry. First wall section shall be 90 cm wide with 30 cm height, and above it, second section of wall shall be 75 cm wide with 30 cm height, and above it, third section of wall shall be 60 cm wide with 30 cm height. and above it, fourth section of wall shall be 45 cm wide with 30 cm height. Above it, a brick (class-75) masonry wall of 30 cm thick with provision of columns of 45 cm x 45 cm at an interval of 3 m along with suitable joints provisions shall be constructed in CM 1:6.,

-

-

-

... More
Access Road to STP with Drains - From gate of STP area to the different units of STP and all around precast concrete interlocking tiles at pedestrian and shoulders shall be of 80 mm thick and approved shape of M 30 grade laid on 75 mm thick PCC 1:4:8 on proper slope with side drainage of vibro-pressed 60 mm thick precast l-shape drains of 0.23X 0.3m on both side laid on 75 mm thick PCC 1:4:8.

-

-

-

... More
Admin-cum-control-cum-laboratory-cum-office with toilet block building as per approved design and drawing by the engineer (maximum area of 15 sqm.)

-

-

-

... More
11 KLD - 25 KLD

1

-

6250000

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).

5.28

-

4259

... More
Brick masonry with F.P.S. bricks of class designation 7.5 in foundation and plinth with bricks Cement mortar 1:4 (1 cement : 4 coarse sand)

36.39

-

4266

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

7.7

-

4759

... More
P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded in wall & 10 cms. projected out complete.

52

-

223

... More
Construction of tubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with "code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemed completed only after obtaining sound free water during pumping. 150mm dai Nominal Bore

50

-

726

... More
Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids . Size 9 to 12 mm

26.22

-

1815

... More
Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.

38.55

-

3388

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

2

-

1036

... More
Electrical Works

-

-

-

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Medium point (up to 6 mtr.)

200

-

360

... More
Long point (up to 10 mtr.)

370

-

465

... More
Wiring of twin control light point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,2 nos. 18 SWG Hot Dipped Galvanized Modular Box with earth terminal ,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / lamp holder/ 3 pin connector ,Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Long point (up to 10 mtr..)

11

-

852

... More
Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles, 18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modular switch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
On board

167

-

246

... More
Short point (up to 3 mtr.)

117

-

315

... More
Medium point (up to 6 mtr.)

200

-

432

... More
Long point (up to 10 mtr..)

267

-

532

... More
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . MMS ( IS:9537 P - III ) PVC conduit

-

-

-

4534

-

30

14947

-

36

1160

-

60

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( 10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
2 x 2.5 sq. mm. + 1x1.5sqmm

4534

-

50

... More
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.

5972

-

71

... More
2 x 6.0 sq. mm. + 1 x 4.0 sq. mm.

80

-

107

... More
4 x 10.0 sq.mm

660

-

274

... More
4 x 16.0 sq.mm

500

-

465

... More
Supplying and drawing RoHS compliance, 75 ohm coaxial cable with 18 AWG Copper Covered Steel conductor/ 14 AWG Copper Covered Steel , Foam FEP insulated shielding (typically aluminum foil, and 95% copper braid), and tolerances are more tightly controlled, to improve impedance stability and protected with PVC sheath, Flame Rating -NFPA 262 , in existing surface or recessed conduit/casing capping including , all as per pre approved by Engineer in charge,making connections, as required. For technical terms and conditions , refer Annexure "A" attached with this BSR . RG -11

270

-

33

... More
Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped & confirming to latest TEC specification , GR / WIR/06-03 March 2002 of following pair in existing surface or recessed PVC/MS conduit/casing capping including all as per pre approved by Engineer in charge, making connections, as required. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
2 pair

1900

-

12

... More
4 pair

1179

-

23

... More
Supply and Laying of 0.6 mm Jelly filled (PIJF) telephone cable confirming to TEC specifications GR/CUG-01/03 in existing conduit/ pipe / open trench or on Cable tray / on surface (by Saddles) including making necessary connection, testing etc. all as per pre approved by Engineer in charge, making connections, as required. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Armoured

-

-

-

... More
20 pair

500

-

264

... More
50 pair

300

-

478

... More
P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

120

-

91

... More
Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISi marking) or Quality Certification such as ISO - 9001 or above , with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x l.S sq.mm pvc insulated flexible copper conductor making connection testing etc. as required . Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .1200mm Sweep BEE 2 Star rated (service value=4.5to 5 )

6

-

1441

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single pole MCB 6 A to 32 A rating

698

-

142

... More
Double pole MCB 6 A to 32 A rating

10

-

405

... More
Four pole MCB

-

-

-

... More
6 A to 32 A rating

19

-

888

... More
50-63 A rating

15

-

1265

... More
Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) as per PWD specification for electrical Works with ISI marked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditional s/c current of 10 KA, truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating, minimum phase termination capacity of 50 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Two pole 30 mA sensitivity

-

-

-

... More
16/25 A rating

57

-

1641

... More
32/40 A rating

45

-

1653

... More
Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
IP-43 Double door (single phase)

-

-

-

... More
8 Way (8 O/G +2 I/C )

10

-

952

... More
IP-43 Double door (Three phase)

-

-

-

... More
6 Way ( 18 O/G + 8 I/C )

33

-

1917

... More
8 Way ( 24 O/G + 8 I/C )

1

-

2373

... More
Providing & Fixing of recessed/surface mounting heavy duty sheet steel 1.6 mm thick End Box as per PWD specification for electrical Works for distribution board duly phophatised powder coated complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
For TPN 6 way DB

33

-

476

... More
For TPN 8 way DB

1

-

509

... More
Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
2 pin Telephone socket

168

-

102

... More
RJ-45 computer jack with shutter

267

-

202

... More
T.V. coaxial socket

10

-

73

... More
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

323

-

397

... More
Providing & Fixing of following size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1 Module

445

-

48

... More
Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1 Module

445

-

53

... More
Providing & Fixing of ISO certified company made vergin material PVC trunking system as per PWD specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tee, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
32mm X 20mm

100

-

123

... More
100/105mm x 50mm

100

-

740

... More
Supplying and fixing of ISO Certified company made Krone module with base frame as per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferruling and punching of telephone cable with krone tool etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
20 Pairs

6

-

743

... More
50 Pairs

4

-

1201

... More
200 Pairs

1

-

5339

... More
Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

18

-

3725

... More
Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped ) Strip

100

-

93

... More
Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25mm x 5mm copper strip

200

-

771

... More
25mm x 6mm G.I. ( Hot Dipped ) Strip

450

-

93

... More
Supply & Laying following size' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 40 mm dia.

160

-

259

... More
Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
300 mm sweep

10

-

2252

... More
450 mm sweep(900/1400 RPM)

22

-

4158

... More
Providing & Fixing of capacitor start, copper wound, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 400 mm sweep (Oscillating type)

176

-

2059

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% ,p.f.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR. 4' LED Tube shape fixture 18/20 W (Extruded Al Base)

199

-

303

... More
Providing & Fixing of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency 85% and in compliance to IEC standards. System Lumen efficacy min. 100 lm/watt, THD 10 % ,p.f.≥0.95, CRI 80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.

-

-

-

... More
Recessed Mounting LED Down light 6/7W

83

-

379

... More
Surface Mounting LED Downlight 18/20W

12

-

612

... More
Providing & Fixing of IP20 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System Lumen efficacy min. 100 lm/watt ,THD 10 % , p.f.≥0.95,CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR. 36W LED 1ight fixture 2'x2' with acrelic/prismetic front cover.

680

-

1893

... More
Providing & Fixing of IP65 IK10 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable for moutning LED tube system (integral driver), system lumen efficacy ≥100 lm/Watt output , THD 15% ,p.f.≥0.95,CRI 80 , life time of minimum 30000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 5 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR. LED BULK head luminaire 9/10W

18

-

1022

... More
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

11706

-

30

... More
Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessory connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. Cat 6, Un-sheilded Information Outlet

528

-

259

... More
Supply, Installation, Testing and Comissioning of Rack mounted 19" 1U, 24 Port Unloaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels (without I.O.) with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel, . There should be a provision for each port/jack on the panel and reusable removable on field from the panel complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

22

-

1792

... More
Supply, Installation, Testing and Commissioning of Wall mounted ISO 9001:2015 & 14001 or higher level certified company made Communication enclosure (Rack) of Minimum 500 MM Depth with made from CRCA & hot dip powder coated, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with fastner of suitable capcity etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6 U wall mounted Enclosure

10

-

6505

... More
12 U wall mounted Enclosure

6

-

9958

... More
Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100 MBPS Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

22

-

34529

... More
Supply , Installation, Testing and Comissioning of following capacity IK10 Sandwich Type Rising Mains / Bus Bar trunking Confirming to IEC 61439 part 1 & part 6 standard & IS 8623 P-II for use on 3 phase 4 wire , 50% internal earth , 415 volts, 50Hz A.C. supply , class F insulation, rated insulation voltage 1000V, impulse withstand voltage 12 KV, min. seismic zone 4 as per IS1892, with IP-54 enclosure made of 1.6mm thick sheet steel duly powder coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA /ASTA lab type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
400 amps 25 KA SC for 1 sec

20

-

15873

... More
500 amps 30 KA SC for 1 sec

20

-

17563

... More
Supply , Installation, Testing and Comissioning of following capacity End Feed Unit Confirming to ANSI C37.23 standard & IS 8623 P-II suitable for Sandwich typy for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
For 400 Amp. (Without MCCB)

1

-

11998

... More
For 500 Amp. (Without MCCB)

1

-

12985

... More
Supply , Installation, Testing and Comissioning of following capacity Plug in / Tap off Box suitable for Sandwich type bus bar trunking Confirming to ANSI C37.23 standard & IS 8623 P-II & IEC-60947-2-2000 for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCB/MCCB / ACB (but without MCB/MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100/125 amps (Suitable for MCCB) without MCCB

6

-

8555

... More
160/200/250 amps (Suitable for MCCB) without MCCB

6

-

9660

... More
SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release

-

-

-

... More
125 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu

6

-

5212

... More
160 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu

6

-

6171

... More
400 Amp ,50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu

1

-

17519

... More
630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu

1

-

23214

... More
External Electrification & Landscape Lighting Work

-

-

-

... More
Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications:- All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . DP : Double pole structure on 2 no ISMB 150 x 100 mm, 10 mtr high using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators LA: 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’

1

-

61855

... More
Supply , Installation, Testing and Comissioning of 11KV, 630 A, 25 kA / 1 Sec, SF6 / VCB Indoor type panel HT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steel , With Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio ( 15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 4 / 8 /10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection ( High oil temperature , Buchholz protection ,high winding temperature), power pack 2 x 12 V,etc complete in all respect Ready To Use(RTU),OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab type test reports before execution complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

-

420701

... More
Supply installation testing & Commissioning of star rated Copper wound distribution Transformer ( All the distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+5% to - 10% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953 , Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 800KVA

1

-

1080752

... More
Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i)Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set (To be supplied by DISCOMs), (iii)TT Block, (iv) 6mm Bakelite sheet on all sides, (V) 3/6 core copper cable for interconnections etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

-

20663

... More
Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required . B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled C. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, with protection and tripping of DG set against temperature of more than 50 degree centigrade

-

-

-

... More
D. Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring & control system, MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : E. (A)Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (B).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (C)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA. F. First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.

-

-

-

... More
G. Servicing of the DG set (as per OEM guidelines) during the DLP period shall be done by contractor including all consumables,actual charges shall be reimbursed to the contractor by department/client complete in all respect. H. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA/ CPCB standards approved lab type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Radiator Cooled & Turbo Charged /AC 380 KVA at 0.8 pf 415V 50Hz 3-ǿ

1

-

2647046

... More
Supply , Installation, Testing and Comissioning of Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . PLC Based: 380 KVA

1

-

256404

... More
Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications including cutting, welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect. OEM Must have BIS certificate and & shall have submit NABL/ OEM lab appropriate type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 100 mm dia

20

-

1550

... More
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

400

-

89

... More
Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3 core 185.0 Sq.mm

500

-

953

... More
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
11 KV End Termination Kit Indoor type 3 core 120/150/185 Sq.mm

6

-

4047

... More
11 KV End Termination Kit Outdoor type 3 core 120/150/185 Sq.mm

2

-

4920

... More
MAIN L.T PANEL CUM EMERGANCY PANEL

-

-

-

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear [c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure "A" attached with this BSR .

25

-

3443

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade

350

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
C T Class 1, Ratio upto 150/5, Burden 5 VA

27

-

355

... More
C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA

30

-

472

... More
C T Class 1, Ratio 1600/5 to 2000/5, Burden 15 VA

3

-

697

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

60

-

127

... More
Blue / white Colour

60

-

209

... More
Providing & Fixing of IP 51 Multi function meter as per PWD specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution & complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .

20

-

3483

... More
SITC of Draw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker (ACB) as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, earth fault and with separate LED indication for each type of fault , Password protected relase (trip mechanisum) shall confirm to EMI/ EMC test , LCD/LED display , Thermal memory , pollution degree 4, trip free mechanisum , suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping fearute , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electrical operation 10,000 upto 2000 A rating and 5,000 for 2500 A. including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . MicroprocessorbasedreleaseDrawouttype(Motorised charging type ) 4Pole

-

-

-

... More
800 A Rating , 50kA

2

-

159280

... More
1600 A Rating ,65kA

1

-

198392

... More
Microprocessor based release Draw out type (Manual spring charged) 3 Pole

-

-

-

... More
800 A Rating , 50kA

1

-

107649

... More
Supply and fixing of following accessories for Air circuit breaker (ACB) compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Shunt Trip Release

2

-

2908

... More
Under Voltage Release

2

-

2830

... More
Earth Fault Release

2

-

1985

... More
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release

-

-

-

... More
upto100Amp,25kA,adjustableO/L&fixedS/Csetting,Ics = 100 % Icu

9

-

5767

... More
160Amp,25kA,adjustableO/L&fixedS/Csetting,Ics=100% Icu

1

-

8664

... More
SITC of IP 40 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C and inst. protection setting , True RMS sensing. as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, common fault LED indication, Thermal memory, release trip shall confirm to EMC/ EMI compatability, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Microprocessor based release

-

-

-

... More
400Amp,50kA,adjustableO/L&adjustableS/Csetting,Ics= 100 % Icu

4

-

33299

... More
630Amp,50kA,adjustableO/L&adjustableS/Csetting,Ics= 100 % Icu

4

-

35818

... More
Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Shunt Trip Release

8

-

1738

... More
Under Voltage Release

8

-

2132

... More
Earth Fault Release

8

-

1701

... More
Extended Rotary Handle

5

-

2064

... More
Direct Rotary Handle

4

-

1295

... More
Motor mechanism for 400A MCCB (240V, 50Hz)

4

-

19618

... More
Motor mechanism for 630A MCCB (240V, 50Hz)

4

-

20580

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single pole MCB

-

-

-

... More
0.5 A to 2 A rating

60

-

210

... More
6 A to 32 A rating

40

-

142

... More
Double pole MCB 6 A to 32 A rating

4

-

405

... More
400KVAR APFC PANEL

-

-

-

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear [c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure "A" attached with this BSR .

16.5

-

3443

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade

100

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA

3

-

472

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Red/yellow/Green colour

27

-

127

... More
Providing & Fixing of IP 51 Multi function meter as per PWD specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution & complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .

1

-

3483

... More
SITC of Draw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker (ACB) as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, earth fault and with separate LED indication for each type of fault , Password protected relase (trip mechanisum) shall confirm to EMI/ EMC test , LCD/LED display , Thermal memory , pollution degree 4, trip free mechanisum , suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping fearute , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electrical operation 10,000 upto 2000 A rating and 5,000 for 2500 A. including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Microprocessor based release Draw out type (Manual spring charged) 3 Pole 800 A Rating , 50kA

1

-

107649

... More
Supply and fixing of following accessories for Air circuit breaker (ACB) compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Shunt Trip Release

1

-

2908

... More
Under Voltage Release

1

-

2830

... More
SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release

-

-

-

... More
upto 100Amp ,25kA , adjustable O/L & fixed S/C setting, Ics = 100 % Icu

2

-

3569

... More
125Amp, 25kA, adjustable O/L & fixed S/C setting, Ics=100 % Icu

6

-

5212

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single pole MCB

-

-

-

... More
0.5 A to 2 A rating

3

-

210

... More
6 A to 32 A rating

4

-

142

... More
Triple pole MCB 6 A to 32 A rating

4

-

636

... More
Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) as per PWD specification for electrical Works, ISI marked IS:13340-41 / conforming to IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.35 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 250 times of rated current, including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Heavy duty Three phase 525 V, 50 Hz cylindrical capacitor (Bank)

400

-

370

... More
Providing & Fixing of IP54 on front microprocessor based three phase sensing power factor correction relay , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, VTHD, ITHD, metering facility as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 12 to 14 stage

1

-

15573

... More
Providing & Fixing of ISO certified company made Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 10 AMP

1

-

254

... More
Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3 pole Power contactors with following AC 3 Rating

-

-

-

... More
13 to 25 Amp

2

-

945

... More
32 Amp.

2

-

2119

... More
70 Amp

2

-

5970

... More
140 Amp

6

-

12211

... More
Providing & Fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Luminous type Red , Yellow, Green, Amber

24

-

161

... More
MAIN HVAC PANEL

-

-

-

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear [c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure "A" attached with this BSR .

20

-

3443

... More
SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attachedwiththisBSR . Electrolytic grade Aluminium bus bar 6010 grade

200

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA

3

-

472

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

47

-

127

... More
Blue / white Colour

3

-

209

... More
Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure "A" attached with this BSR . Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .

1

-

3483

... More
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release upto 100Amp, 25kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu

22

-

5763

... More
Providing&Fixingof240/415VResidualcurrentcircuitbreaker(RCCB)asperPWDspecificationforelectricalWorkswithISImarked(IS:12640-1)/conformingtoIEC61008-1,ratedconditionals/ccurrentof10KA,trulycurrentoperatedandshalloperateonCBCTmechanisum,provisionforpadlock,min.operation10,000upto63Aratingand5000for100Arating,minimumphaseterminationcapacityof50sq.mm.rigidwire,IP20contactprotectionwithexistingdistributionboard/sheetincludingmakingconnections,testingetc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtestreportsbeforeexecution&AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attachedwiththisBSR . Four pole 100/300 mA sensitivity 63 A rating

22

-

210

... More
MAIN VENTILATION PANEL

-

-

-

... More
Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) as per PWD specification for electrical Works with ISI marked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditional s/c current of 10 KA, truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating, minimum phase termination capacity of 50 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

20

-

3443

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade

150

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
C T Class 1, Ratio upto 150/5, Burden 5 VA

45

-

355

... More
C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA

3

-

435

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

33

-

127

... More
Blue / white Colour

3

-

209

... More
Providing & Fixing of IP 51 Multi function meter as per PWD specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution & complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .

16

-

3483

... More
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release 160Amp,25kA,adjustableO/L&fixedS/Csetting,Ics=100% Icu

1

-

8664

... More
Supply Installation testing & Commissioning of ISO certified company made DOL/Star-Delta Starter panel made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
5.0 HP ( DOL starter )

4

-

4500

... More
7.0 HP ( DOL starter )

7

-

4500

... More
10.0 HP ( Star / Delta starter )

4

-

6614

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Four pole MCB 50-63 A rating

2

-

1265

... More
GROUND FLOOR LIGHTING PANEL

-

-

-

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear [c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure "A" attached with this BSR .

10

-

3443

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade

50

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . C T Class 1, Ratio upto 150/5, Burden 5 VA

3

-

355

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

3

-

127

... More
Blue / white Colour

3

-

209

... More
Providing & Fixing of IP 51 Multi function meter as per PWD specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution & complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .

1

-

3483

... More
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release 125Amp, 25kA, adjustable O/L & fixed S/C setting ,Ics= 100 % Icu

1

-

7029

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Four pole MCB

-

-

-

... More
6 A to 32 A rating

5

-

1211

... More
50-63 A rating

5

-

1265

... More
UPPER FLOOR LIGHTING PANEL 4 NOS.

-

-

-

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear [c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure "A" attached with this BSR .

40

-

3443

... More
SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/Copper(IEC60028)busbarasperPWDspecificationforelectricalWorks,bymeansofSMC/DMCtypeinsulator,hightensilenutsandboltsspringwashersinexistingpanelincludingbending,cuttinginrequiredshapeandsizeandcolourcodingwithheatshrinkablePVCsleeves.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attachedwiththisBSR . Electrolytic grade Aluminium bus bar 6010 grade

200

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . C T Class 1, Ratio upto 150/5, Burden 5 VA

12

-

355

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

12

-

127

... More
Blue / white Colour

12

-

209

... More
Providing & Fixing of IP 51 Multi function meter as per PWD specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution & complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .

4

-

3483

... More
SITCofIP40quickmakeandquickbreak4polecurrentlimitingMouldedcasecircuitbreaker(MCCB)madeofflameretardent&heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/CsettingsasperPWDspecificationforelectricalWorks,conformingtoIS/IEC60947P-2:2003withfrontfaceandcentralisedadjustable,tripfreemechanisum,truecontactpositionindicator,lineloadinterchangeability,designedforbothhorizontal&verticalmountingwithoutanyadverseeffectonelectricalperformance,suitableforoperationupto55degreeandwithoutderatingupto40degree,pollutiondegree3,havingpositiveisolationcapability,push(test)totrip,triptimelessthen10msunders/ccondition,BreakingcapacityIcs=100%Icu.Uimp=8KV,ratedinsulationvoltage800V,provisionforUVR,shunttrip,earthfaulttrip,doorinterlock,padlock&rotaryhandle,includingmakingconnectionswithlugs&spreaders,etc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestcertificatebeforeexecution.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure "A" attached with this BSR . With Thermal Magnetic release

-

-

-

... More
125Amp,25kA,adjustableO/L&fixedS/Csetting,Ics=100 % Icu

4

-

7029

... More
Providing&Fixingof240/415VACMCBwithpositiveisolationofbreakingcapacitynotlessthan10KA(B/Ctrippingcharacteristicaspertypeofloadandsiterequirement)4KVimpulsewithstandvoltage,asperPWDspecificationforelectricalWorkswithISImarkedIS8828(1996)/conformingtoIEC60898-12002,IEC60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof35sq.mm.,conductorlineloadreversibility,labelholdingfacility,IP20contactprotectionandfittedwithexistingdistributionboard/sheets,min.operation20,000upto32Aratingand10,000upto63A,5000for80Aratingincludingmakingconnections,testingetc.asrequired..OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtestreportsbeforeexecution&AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attachedwiththisBSR . Four pole MCB 6 A to 32 A rating

20

-

1211

... More
ALL FLOOR POWER PANEL 5 NOS.

-

-

-

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear [c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure "A" attached with this BSR .

50

-

3443

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade

250

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA

15

-

435

... More
Providing&FixingofISOcertifiedcompanymadeULlisted,IP65110/220V,unibodyLEDIndicatinglampIEC60947,CSA22.2withintegralcircuit,IP20terminalblock,Approx.bodydiaforpanelnotlessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29mm,contactmaterialphospherbronzeforLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,Ratedinsulationresistanceshallbe100Mohmat500VDCincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attachedwith this BSR .

-

-

-

... More
Red/yellow/Green colour

15

-

127

... More
Blue / white Colour

15

-

209

... More
Providing&FixingofIP51MultifunctionmeterasperPWDspecificationforelectricalWorks,ISImarked(IS16444)/ConfirmingtoIEC61557&IEC62052withLCD/LED3/4linedisplaycapableofmeasuringelectricalparameterslikeV,I,F,PF,KW,Kva,Kvar,Kwh,Kvah,Kvarhdisplaywith1A/5ACTinputforLV/HVnetwork,with/withoutRS485communicationportetc.OEMMusthaveBIScertificateand&shallhavesubmitNABL/CPRI/ERDAlabtestreportsbeforeexecution&completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/ work , refer Annexure "A" attached with this BSR . Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .

5

-

3483

... More
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release 160Amp,25kA,adjustableO/L&fixedS/Csetting,Ics=100% Icu

5

-

8664

... More
Providing&Fixingof240/415VACMCBwithpositiveisolationofbreakingcapacitynotlessthan10KA(B/Ctrippingcharacteristicaspertypeofloadandsiterequirement)4KVimpulsewithstandvoltage,asperPWDspecificationforelectricalWorkswithISImarkedIS8828(1996)/conformingtoIEC60898-12002,IEC60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof35sq.mm.,conductorlineloadreversibility,labelholdingfacility,IP20contactprotectionandfittedwithexistingdistributionboard/sheets,min.operation20,000upto32Aratingand10,000upto63A,5000for80Aratingincludingmakingconnections,testingetc.asrequired..OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtestreportsbeforeexecution&AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure"A"attachedwiththisBSR . Four pole MCB 50-63 A rating

35

-

1265

... More
EXTERNAL LIGHT FEEEDER PILLAR

-

-

-

... More
SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0 mm above 600mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side wall sand cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate M.S.base channel (min75mm), hinged door with locking arrangement for equipment/switchgear [c) Inter connection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (upto125amp) and by solid busbar (125amp). All joints / interconnections of copper busbar shall be dully tinned. Clearance between main busbar and risers / metal parts shall be atleast 10 mm additional to width of busbar Busbar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing preapproved by Engineerincharge. For additional technical parameter so foroducts / work , refer Annexure "A" attached with this BSR .

15

-

3443

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade

35

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . C T Class 1, Ratio upto 150/5, Burden 5 VA

3

-

355

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

3

-

127

... More
Blue / white Colour

3

-

209

... More
Providing & Fixing of IP 51 Multi function meter as per PWD specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution & complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port .

1

-

3483

... More
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release

-

-

-

... More
upto100Amp,25kA,adjustableO/L&fixedS/Csetting,Ics = 100 % Icu

1

-

5767

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Four pole MCB 6 A to 32 A rating

8

-

1211

... More
Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.) 7 Mtr.

19

-

12841

... More
Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single arm overhang

17

-

885

... More
Double arm overhang

2

-

1558

... More
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy =120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified.

-

-

-

... More
Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . LED Street Light fixture 45 Watt

22

-

4283

... More
Pipe Earthing as per PWD specification for electrical Works as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

6

-

2191

... More
Plate Earthing as per PWD specification for electrical Works as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

8

-

8694

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 8 SWG copper Wire

750

-

81

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Armoured Cable

-

-

-

... More
6.0 Sq. mm

-

-

-

... More
3 Core

250

-

75

... More
4 Core

750

-

84

... More
16.0 Sq. mm

-

-

-

... More
3 Core

750

-

104

... More
4 Core

400

-

123

... More
25.0 Sq. mm 3 Core

300

-

137

... More
50.0 Sq. mm 3.5 Core

500

-

235

... More
95.0 Sq. mm 3.5 Core

150

-

386

... More
150.0 Sq. mm 3.5 Core

750

-

570

... More
240.0 Sq. mm 3.5 Core

300

-

889

... More
300.0 Sq. mm 3.5 Core

200

-

1088

... More
Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 -1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3 x 6.0 sq.mm

12

-

60

... More
3 x 16.0 sq.mm

30

-

79

... More
4 x 16.0 sq.mm

10

-

88

... More
3.5 x 25.0 sq.mm

38

-

94

... More
3.5 x 50.0 sq.mm

16

-

127

... More
3.5 x 95.0 sq.mm

20

-

216

... More
3.5 x 150.0 sq.mm

24

-

365

... More
3.5 x 240.0 sq.mm

4

-

540

... More
3.5 x 300.0 sq.mm

12

-

715

... More
supplying, installation, Testing and commissioning of the passenger/goods/Stretcher or Bed elevator having following main features: (a) MOTOR : Gearless lift drive comprising of high starting torque lift duty , 3 phase 440 Volts A.C. permanent magnetic synchronous motor of proper rating with high efficiency shall be used. (b) Operation / Drive : Microprocessor based /PLC, AC Variable Voltage variable frequency variable speed (V3F) vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response , UP/Down hall stops , main , Up/Down contactor with overload and phase reversal relay and safety controls. (c) Traction Media: main hoist flat coated steel belt / rope . Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt.

-

-

-

... More
(d) Car : car should be with M S platform with bracings of adequate size and to sustain the impact load cabin plus passengers with safety factor of fire for steel with Anti-skid PVC flooring and side panels should be of Stainless steel with hair line finish of sheet of grade 304 duty with S.S. handrails . Car ceiling shall be steel finish with aesthetic appearances with LED ceiling lights .The size of the car shall be taken as per available lift well size and relevant BIS code of lifts. Car panel will also be of S S 304 grade finished with emergency stop device, emergency alarm, mechanical door safety device, full length infra-red curtain in car door, facility of auto/attended mode. All car panel buttons and all floor switches must be with brail language as per lift act. Agency shall also provide & install one No. 2 MP , IR , IP based ceiling mounted Dome Camera in the car complete with connecting cables & accessories (To be connected with existing CCTV system in the Building) .The inspection unit shall be provided at the top of the car.

-

-

-

... More
(e) Landing Doors: All landing door shall be fully automatic centre opening / telescopic made of hair line finish stainless steel grade 304 with key holes and infrared curtains with unlocking facility from outside. (f) Emergency light: Appropriate rechargeable battery operated LED emergency light in the car and along with alarm switch shall be provided. (g) ARD: Automatic rescue Device (ARD) shall be provided according to passenger capacity with SMF batteries of approved brands as per BSR. (h) Audio-Visual Indication: Audio visual indication in the lift car, showing over loading such that doors kept open till excess load is removed. (i) Scrolling Indicators: Digital scrolling indicator system for up-down arrow with floor position indicator shall be provided inside the car and at all stops/floors. (j) Buffers: Spring buffers/PU Buffers shall be provided. (k) Car Fan: ENERGY EFFICIENT Car fan/blower with automatic sleep timer shall be provided. (l) Voice Annunciator: Voice annunciator with suitable music shall be provided in lift car.

-

-

-

... More
(m) Self diagnostics system for operational and safety parameters shall be provided in control panel. (n) chanical/Electronic over speed governor, door key holes in the floor doors, fireman switch shall be provided. (o) Lift machine hoisting arrangement in the lift machine room, counter balance to promote smooth and economic operation complete with steel guide rails for the car & counter weight, Trap Door, Lifting hooks as required and monkey ladders for lift pit should be provided by the agency along with all other steel structure works, foundations for the machine etc as required. (p) Permanent wiring in lift machine room and in lift well with providing and fixing of electrical distribution board complete with SP & TP MCB's , proper numbers of light points, with LED fixtures , exhaust fan , 2 nos copper plate /chemical earthing with 8 SWG copper earth wire and plug points shall be provided by the agency . (Power supply of 3 phase 440 V shall be made available by department in lift machine room.)

-

-

-

... More
(q) All civil work related to installation of lift like finishing, cleaning and levelling of lift pit , white wash of lift well and in machine room shall be done by the lift erecting agency without any extra cost. (r) Granite or marble cladding around all landing door openings shall be in the scope of lift installation agency and additional payment shall be made according to the actual measurement / schedule by the department to the lift agency. (s) Agency has to provide all working drawings and documents to comply latest BIS specifications and make proper liaison services for obtaining all necessary permissions. 10 passengers/680 Kg , 6 stops , rated speed adjustable up to 1.0 mtr /sec with 2 years comprehensive maintenance / DLP

3

-

1657943

... More
CCTV Wiring

-

-

-

... More
S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit of apropriate thickness related to its dia as per PWD specification for electrical Works along with accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, screwas etc. as required including cutting the wall and making good the same as required all as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

2000

-

79

1500

-

99

500

-

140

... More
Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . RJ-45 computer jack with shutter

114

-

202

... More
Providing & Fixing of following size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1 Module

114

-

48

... More
Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1 Module

114

-

53

... More
FIRE FIGHTING WORKS

-

-

-

... More
Supplying, Installation, Testing & Commissioning of central govt./ state govt. authorised Fire authority approved Electric Driven Main fire pump for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given as A, B, C, D, E,F,G and H. (A) Horizontal Single / Multi stage Centrifugal End suction, back pull out type pump complete for delivery of below mentioned discharge ,including bypass arrangement for Testing of pump (B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal (C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head

-

-

-

... More
(D) Squirrel cage induction motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 suitable for 3 phase, 415 V, 50 HZ, Ac supply 2900 / 1450 RPM T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible coupling , coupling guard complete in all respect . ( E) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads. (F) Pump must be inspected by third party like RITES / PDIL at manufacturer's premises and inspection report is to be submitted. (G) Suitable cement concreat foundation (1:3:6) duly plastered with (1:4) ratio (H) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 2280 LPM suitable for 70 Mtr Head, single stage, 2900 RPM

1

-

246018

... More
Supplying, Installation, Testing & Commissioning of central govt./ state govt. authorised fire authority approved Diesel Engine driven Pump suitable for automatic operation as per discharge defined beolw consisting of the following details given as A, B, C, D, E ,F and G .

-

-

-

... More
(A) Horizontal Single / Multi stage Centrifugal End suction, back pull out type pump complete for delivery of below mentioned discharge ,including bypass arrangement for Testing of pump

-

-

-

... More
(B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal

-

-

-

... More
(C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head

-

-

-

... More
(D) Radiator cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1500 / 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump,Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter minimum 10 M length (with insulation & Cladding), with muffler, day oil tank of 300 Lts capacity with piping

-

-

-

... More
(E) Pump is to be inspected by third party like RITES / PDIL at manufacturer's premises and inspection report is to be submitted.

-

-

-

... More
(F) Suitable cement concreat foundation (1:3:6) duly plastered with (1:4) ratio

-

-

-

... More
(G). First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.

-

-

-

... More
Appropriate OEM/ NABL lab test reports shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
2280 LPM suitable for 88 Mtr Head, multi stage, 1500 RPM

1

-

679245

... More
Supplying, Installation, Testing & Commissioning of central govt./ state govt. authorised fire authority approved Horizontal single stage Jockey pump with CI Body, Bronze impellor, SS shaft, mechanical seal coupled with Squirrel cage induction motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 for automatic operation suitable for three phase, 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM ,T.E.F.C type confirming to IP:55 with flexible coupling and coupling guard with the pump ,Common bed plate fabricated from mild steel channel Suitable cement concreat foundation duly plastered with anti vibration pads.complete in all respect. Appropriate OEM/ NABL lab test reports shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 180 LPM suitable for 88 Mtr

1

-

101511

... More
Supplying, Installation, Testing & Commissioning of floor mounted dust and vermin proof compartmentalised cubical type main fire pump control panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors and having accessories/ switch gear (as per Specf Ch-06 & 08) as below:- complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
INCOMING

-

-

-

... More
400 Amp. TPN MCCB (adj.O/L) with Extended ROM, 36 kA, with Thermal magnetic release, Analouge Ammeter, Voltmeter, Selector switches,CT, Indicating Lamps, 500 Amps FP Alum. Bus bar with with heat shrinkable sleeves.

-

-

-

... More
OUTGOING

-

-

-

... More
(a) 200 Amp. TPN MCCB(adj.O/L) with Extended ROM, 36 kA, with Thermal magnetic release, Analouge Ammeter, Voltmeter, Selector switches,CT, Indicating Lamps for 'ON', 'OFF', 'TRIP' 1 no. DOL Starter of rating upto 75 HP with thermal over load relay, timer, push buttons, Auto / Manual selector switch, Single phase preventor - 2 Sets

-

-

-

... More
Main Fire Pump

-

-

-

... More
(b) 63 Amp. TPN MCCB (adj.O/L) with Extended ROM, 16 kA, with Thermal magnetic release, Digital Ammeter, Voltmeter, Selector switches, CT, Indicating Lamps for 'ON', 'OFF', 'TRIP' 1 no. DOL Starter of 5 - 15 HP with thermal over load relay, timer, push buttons, Auto / Manual selector switch, Single phase preventor - 1 Set

-

-

-

... More
(c) One no. Diesel Engine Auto Starting kit with Auto Manual selector switch & 3 attempt starting device, timers, relays, Indicating lamp for High / Low Lub. Oil pressure, High water temperature and engine ON indication, DC ammeter & voltmeter

-

-

-

... More
(d) System controller to control Operation Main Electric pumps, Diesel pump, jockey pump in sequence consisting of relays, timers, sensors, annuciation window for fault indication.

-

-

-

... More
(e) Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted.

1

-

186129

... More
PIPES & ACCESSORIES

-

-

-

... More
Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications underground rings including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer with compressed asbestos gaskets, nuts, bolts etc. including laying of pipe in excavted trench of 1.0 mtr depth with cleaning,wrapping and coating of the pipe with 4 mm thick tar based polymaric corrosion protection tape including applying uniform coat of cold pipekot primer as per IS; 10221 for protection against corrsion.complete in all respect. (Excavtion of trench shall be paid extra as per Item no E130500 ). Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect.Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
80 mm. Dia

20

-

1020

... More
150 mm. Dia

250

-

2114

... More
Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class pipes conforming to IS 3589 / 1239 part-I for hydrent and sprinkler applications including cutting, screwing, welding etc & malleable iron fittings like elbows, tees, flanges, tapers, reducer, with compressed asbestos gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts as per approved spacing. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of Post office red shade complete as required.Complete installtion shall be pressure tested at 14kg/sqcm for 24 hr as per practice complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25 mm dia

500

-

295

... More
32 mm dia

250

-

381

... More
40 mm dia

100

-

432

... More
50 mm dia

80

-

603

... More
65 mm dia

100

-

736

... More
80 mm dia

100

-

890

... More
100 mm dia

80

-

1267

... More
150 mm dia

20

-

1855

... More
200 mm dia 6.0 MM thck

15

-

2560

... More
Providing, Fixing, Testing & Commissioning of single headed obligue pattern hydrant landing valve (internal/external) ISI marked confirming to IS:5290-1983 (Type-A) /IS: 908 - 1975 with 80 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with cap and chain, twist release type plug and all accessories complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Gun Metal Material

18

-

7626

... More
Supplying, fixing, testing commissioning of butterfly valve (PN 16) with Bronze/ Gunmetal seat duly ISI marked conforming to IS 13095-1991 complete with flanges,Nuts, Bolts, washers, gaskets of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
50mm dia

10

-

2116

... More
80 mm dia

5

-

2551

... More
100 mm dia

8

-

3543

... More
150 mm dia

4

-

4904

... More
200 mm dia

2

-

9545

... More
Supplying and fixing orifice plate made of 6 mm thick stainless steel with orifice of required size in between flange & landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm2 complete with rubber gasket, GI bolts, nuts, washers etc. as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

29

-

1051

... More
Supply, installation, testing and commissioning of dual plate nonreturn valve (PN-16) of following sizes confirming to IS:5312 -1975 complete with flanges,rubber gasket, nut,bolts, washers etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100mm dia

2

-

6937

... More
150mm dia

2

-

9922

... More
250mm dia

1

-

16629

... More
Supplying and Fixing of Y type strainer fabricated out of cast iron/ steel body, strainer shall have 1.6 mm. thick stainless steel sheet perforated screen with 3 mm. dia holes with flange at both ends complete with nuts, bolts, washers, gaskets etc of following sizes. complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 200 mm dia

2

-

12644

... More
Supplying and fixing of Non-percolating flexible hose (RRL type-A) ISI marked confirming to IS:636, 63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia male and female couplings (Confirming to IS:903) duly bound and riveted to hose pipes with copper rivets and copper wire etc. as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . with Gun Metal Coupling

18

-

5235

... More
Supplying & fixing Short Branch Pipe with Nozzle ISI marked conforming to IS: 903, made of following material , fitted with 20mm (nominal internal diameter) bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Gun metal Material

18

-

2461

... More
Supplying and fixing Fire Brigade In let Connection of CI body with Gun Metal/stainless steel male instantaneous inlet couplings complete with PVC blank cap and chain as required for 150mm dia MS pipe connection, conforming to IS 903 as required of following way :- complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 4 way -

1

-

9020

... More
Supplying and fixing cylindrical air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia drain valve,air release valve,safety valve pressure gauge with required accessories and painting with two coats of Red Oxide and two coat of post office red enamel paint as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

3

-

20452

... More
Providing & fixing 100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg ) range, 3 / 8 " BSP bottom entry on Pump Delivery Line complete with Ball valve complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

8

-

825

... More
Providing & fixing vane type water flow switches with contacts for installation in 50 mm to 150 mm dia M.S. pipe for a service pressure up to 20 Kg / Sq.cm complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

-

4712

... More
Providing & fixing testing & commissioning of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 150 mm dia as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

-

35758

... More
Providing, installation, testing and commissioning of Brass ball valves (PN-16) duly ISI marked confirming to IS : 9890-1981 complete with flanges,Nuts, Bolts, washers, gaskets etc of following sizes as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 25 MM DIA

8

-

656

... More
Providing & fixing of size 0.9 M wide x 1.8 M height Indoor Hose Cabinet shutter suitable for accomodating hydrants made of Tubular rectangular pipe (50X25mm) having central opening 6mm thick glass glazed door having necessary locking arrangement, painting (one coat primer & two coats of paint) suitable for housing 2 Nos. RRL hose pipe, 1 no branch pipe, first Aid hose Reel etc . as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

17

-

8169

... More
Supplying and fixing first -Aid Fire hose reel wall mounted swinging type with MS construction spray painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required. (A) 30 m long 20 mm (nominal internal) dia water hose (B)20 mm (nominal internal) dia gun metal globe valve & nozzle 5mm orifice (C)Drum and brackets for fixing the equipments on wall. (D) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. pipe complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . with High Pressure Braided Rubber Hose as per IS:5132 - 1969

12

-

9423

... More
Supplying and fixing Fire Brigade In let Connection of CI body with Gun Metal/stainless steel male instantaneous inlet couplings complete with PVC blank cap and chain as required for 150mm dia MS pipe connection, conforming to IS 903 as required of following way :- complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 2 way 100 mm dia M. S. Pipe

2

-

6069

... More
Providing, fixing, testing & commissioning of 15 mm dia size quartzoid bulb type sprinkler heads suitable for 68 degree centigrade rating standard response (UL/FM/LPC/TAC Listed/Approved) chrome plated complete in all respect of the following type complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Pendent Sprinkler

750

-

217

... More
Supply and Fixing of Stainless Steel Flexible Hose Pipe, Made of Corrugated Stainless Steel, Rated Pressure 200psi –Assembly complete with: Inlet nipple with 1” NPT male thread, outlet reducer with 1/2" NPT female thread to sprinkler head, 700mm Square Bar, Centre Clamp & 2 Nos side brackets. complete as required complete in all respect. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 700mm

750

-

899

... More
Supply & Fixing of Fire Man's Axe with carbon steel head & rubber moulde handel and confirming to IS :926 with length approx 0.4 M & weight 3.0 Kg. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

12

-

697

... More
Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 6kg

12

-

4920

... More
Supply & Fixing of current and valid BIS certification IS: 15683:2018 approved Portable fire Extinguisher, Carbon‐dioxide type flat base including valve, discharge hose of not less than 10 mm dia. min. 600 mm long & complete in all respects including initial fill with C02 gas confirming to IS:307‐1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket . bidder must have valid PESO license to refill and store compressed gas cylinders as per Gas Cylinder rules 2004 , vessel should be PESO Approved. carbon dioxide gas shall conform to IS 15222 with latest amendment. Co2 Cylinder shall be conform to all the requirement given in IS 7285:2004. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 4.5 KG

12

-

10073

... More
SITC of UL 10th edition / EN54 VDS approved IP40 Analog addressable Multi criteria (two optical/Smoke sensor to reduce false alarm ) type Photo smoke detector with mounting base & LED etc including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . with inbuilt isolator or with isolator base

335

-

3071

... More
SITC of IP40 Analouge Addressable type Heat Detectors (Thermal Detectors): GRADE-I with solid state design with sensing element combination of fixed type and rate of rise of temperature mounting base & LED shall have UL 10th edition / EN54 VDS approved certification etc including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . with inbuilt isolator or with isolator base

79

-

2866

... More
Supply, Installation, Testing and Commissioning of IP 40 Stand alone Loop Powered Addressable sounder with 5 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 90 dB , it should be programmed from the panel. Shall have EN54 /UL Certification including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . with inbuilt isolator or with isolator base

12

-

2777

... More
Supply, Installation, Testing and Commissioning of IP52 Addressable (MCP) Manual Break Glass/ flap Unit (Double action) shall have UL/EN54 certification shall be constructed of Lexan with clearly visible operating instructions provided on the cover. The word FIRE should appear on the front of the stations in raised letters, including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . with inbuilt isolator or with isolator base

12

-

3140

... More
Supply, Installation, Testing and Commissioning of Stand alone Loop Powered Addressable strobe light Shall have EN54 /UL Certification.including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . with inbuilt isolator or with isolator base

12

-

2209

... More
SITC of Response Indicator for addressable type detectors as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

35

-

593

... More
Supply installation testing and commisisioning of Addressable control (input/output) modules/ Relay Module for shutting down lifts, AHU's, Acknoledgement of Sprinkler system etc. with potential free contact monitoring Shall have EN54 /UL Certification. including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . with inbuilt isolator or with isolator base

21

-

3961

... More
Supply, Installation, Testing and Commissioning of Microprocessor based inteligent, Analogue addressable fire alarm panel with CPU redredundancy & min 640 charactor/ 6" touch screen display , shall have UL 10th edition / EN54 VDS approved certification, modular, expandable networkable loop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 250 detectors & devices with Loop length up to 1.5 KM. Minimum 5000 history event facility . Panel shall be Compatible for Seamless integration with PA system and both system should be of the same make. The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, inbuilt networking port (both RS485 & Ethernet),Serial port for printer, two supervisory inputs,two position key switch and USB port for programming. including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
2 - Loop Panel

1

-

199648

... More
Add Extra for per Loop expansion beyond Two Loop

1

-

42265

... More
Supply, Installation, Testing and Commissioning Active Repeater Panel for Fire Alarm System with UL/EN54 certification with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

-

65531

... More
Supply , installation testing and commisioning of EN-54 Certified IP based PA controller capable of adding 12 ZONE and expandable upto 50 zones with full digital functionality same with FACP OEM, it shall contain 12 speaker line outputs. 5000 fault warning and event conditions log. Built in message manager for 60 emergency/ business calls up to 60 minutes. It also contains EN-54 certified Call Station with extension keypad to serve minimum 12 zones, gooseneck microphone with supervised electret microphone, integrated loudspeaker for system sounds, customizable function and speed dial buttons. Possible to use keys (push buttons) for Zone select, source select, level control, emergency on/off, message on/off, failure acknowledge/reset. Call Station is completely supervised by system controller. Power Amplifier of 480 W in a 3U high housing with 70 V / 100 V and 8 ohm outputs,Dual inputs with priority switching,100 V input for slave operation on 100 V speaker line, Mains, battery back-up, including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect.OEM appropriate test certificate shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

-

332396

... More
Supply, installing,testing & commissioning of PA system Operator Console of following wattage to be installed with Conventional fire alarm system complete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console , equipment rack complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1x 350 Watt

1

-

51951

... More
SITC 6 watt Speaker mounted in M S sheet box with perforated front mesh for PA and Emergency System complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

250

-

792

... More
Providing, Fixing, of Photo luminescent Self charge EXIT Sign boards of approximate size 12" x 6" The colour combination and letter size shall be in accordance with IS: 9457-1980, IS: 12349-1988. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

40

-

963

... More
S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit of apropriate thickness related to its dia as per PWD specification for electrical Works along with accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, screwas etc. as required including cutting the wall and making good the same as required all as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 20 mm

4500

-

79

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( 10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 2x 1.5 sq.mm

4500

-

24

... More
HVAC SYSTEM

-

-

-

... More
DRAIN PIPING FOR VRV/VRF - Indoor Units

-

-

-

... More
Providing & Fixing of ISI marked (IS : 4985 - 2000) Hard rigid PVC 25mm drain water piping with fittings like elbow, soket, Tee etc & support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

300

-

136

... More
CEILING MOUNTED DUCTABLE SPLIT AC

-

-

-

... More
SITC of ISO certified company made air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R-32/R-410A R-407 Green refrigerant comprising of single/twin Scroll / Rotary / Reciprocating type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system,with min 5 year OEM warranty both compressor and PCB , Suitable capacity squirrel cage induction motor with class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine isolation / disconnect switch, valves and accessories to inter conne ct compressor and condender including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L , U/V, phase reversal protection, single phase preventors etc complete as required.

-

-

-

... More
NABL accredeated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Ductable Split type 16.5/ 16.7 TR (ISEER not less then 4.7 )

1

-

325419

... More
Supply , Installation, Testing and Comissioning of ducting made from GSS of class VIII & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following gauge:- All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 0.63mm (24 G)

150

-

627

... More
Supplying, installing, testing and balancing of extruded Aluminium powder coated Air Diffuser and complete with Flush, 20mm flanges with PVC/neoprene gasket, anti – smudge frame and removable inner core to facilitate the adjustable of air control damper, square/round/ rectangular as required.including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Supply Air Diffuser with Volume Control damper

8

-

9140

... More
Return Air Diffuser without Volume Control damper

8

-

5743

... More
Supplying, installing and balancing of extruded Aluminium powder coated fresh air inlet louvers with bird screen & volume control damper fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

-

13034

... More
Supplying, installing, testing and balancing of double louvered of extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Supply air grill with key operated volume control damper

4

-

11632

... More
Return air grill without volume control damper

3

-

8234

... More
Supplying, installing of external thermal closed cell cross linked polyethelene (XLPE) foam insulation made out from non-fibrous, fire retardant (FR), closed cell, tri-dimensional chemically crosslinked polyethylene foam. should be certified 'Class O' in Fire Propagation and 'Class 1' in Surface Spread of Flame as per BS 476 Part 6 & Part 7 respectively in the form of sheet on ducts including cost of adhesive, tape complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 13mm thick

300

-

694

... More
Supply , Installation, Testing and Comissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB. NABL accredeated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391(Part-2) 2018 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Non-Invertor Type 1.8/2.0 TR with 3 star rating of BEE (ISEER not less then 3.7 )

5

-

49459

... More
SITC of 2 MP IR Fixed Bullet Network Camera -1/2.8″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection, False alarm reduction through human and vehicle target classification based on deep learning UL, CE, FCC certified.

39

-

7500

... More
SITC of IP Automatic Number Plate Recognition analytics: 1/1.8′′Progressive Scan CMOS, 1920 × 1080 at 60fps, 5.3 to 13 mm lens, ICR, ONVIF, support H.265, H.264,MJPEG, 3D Digital Noise Reduction, 24 V DC ± 20%, Support IR-50m,Support on-board storage up to 128 GB (TF card not included), License Vehicle detection with inbuilt independant automatic License plate recognition system working on optical character recognition technology. Camera should provide clear image of license plate along with recognized license plate no. and capture time, UL, CE, FCC certified.

2

-

55600

... More
SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified.

71

-

6500

... More
SITC of 2MP IR Outdoor PTZ Camera with 32X: MP, 1/2.8" CMOS,H.265+/H.265/H.264+/H.264 codec, 3D DNR, True WDR, Ultra-low light Powered By DarkFighter Color: 0.005lux/F1.6, B/W:0.001lux/F1.6, Optical Zoom:32x, Digital Zoom:16X?150m IR 1920*1080:30fps, Pan Speed: 0.1?-120?s, Tilt Speed: 0.1?-80?s, PoE+&24VAC Smart Detection

2

-

65300

... More
Supply Installation testing and commissioning of 64 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified including cost of hard disk and 900VA UPS.

2

-

125400

... More
SITC of 42 inch full HD professional LED display for CCTV monitoring.

2

-

45000

... More
VRV/VRF - Outdoor Units

-

-

-

... More
Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .

-

-

-

1

-

512840

2

-

493995

3

-

449593

2

-

418324

5

-

405898

1

-

339428

2

-

328476

... More
VRV/VRF - Indoor Units

-

-

-

... More
Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature complete as per the technical specification.

-

-

-

... More
3.20 TR/1130 CFM including Ref. 'Y' Joint

1

-

52601

... More
2.64 TR/794 CFM including Ref. 'Y' Joint

20

-

50539

... More
2.08 TR/741 CFM including Ref. 'Y' Joint

26

-

44974

... More
1.65 TR/635 CFM including Ref. 'Y' Joint

30

-

44352

... More
1.00 TR/459 CFM including Ref. 'Y' Joint

70

-

38068

... More
REFRIGERANT PIPING FOR VRV/VRF SYSTEM

-

-

-

... More
Supply, Installation, Testing & Commissioning including vaccumization and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE Class-O tubular insulation/with Clss-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories should be as per specifications etc. as required.

-

-

-

... More
6.35 mm dia (OD), Soft Drawn with tube thickness 1.2 mm with 13 mm thick insualtion.

70

-

909

... More
9.53 mm dia (OD), Soft Drawn with tube thickness 1.2 mm with 13 mm thick insualtion.

75

-

1006

... More
12.70 mm dia (OD), Soft Drawn with tube thickness 1.2 mm with 13 mm thick insualtion.

75

-

1168

... More
15.88 mm dia (OD), Soft Drawn with tube thickness 1.2 mm with 19 mm thick insualtion.

75

-

1363

... More
19.05 mm dia (OD), Hard Drawn with tube thickness 1.2 mm with 19 mm thick insualtion.

100

-

1623

... More
22.23 mm dia (OD), Hard Drawn with tube thickness 1.2 mm with 19 mm thick insualtion.

100

-

1785

... More
25.4 mm dia (OD), Hard Drawn with tube thickness 1.2 mm with 19 mm thick insualtion.

140

-

2012

... More
28.58 mm dia (OD), Hard Drawn with tube thickness 1.2 mm with 19 mm thick insualtion.

140

-

2142

... More
AXIAL FLOW FAN

-

-

-

... More
Supply, installation, testing and commissioning of ceiling mounted/floor mounted (as per requirement) Tube Axial flow fans with adjustable pitch blade, MS / GI long casing (2mm thick up to 800 mm dia fan, 3 mm thick from 900 to 1250 mm dia & 4 mm thick above 1300 mm dia) , cast aluminium alloy impeller complete with TEFC IE3 Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, three phase A.C supply with support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep (Inlet & Outlet as required), bird screen (Inlet & Outlet as required) etc. & of following capacity. The complete fan along with motor shall be suitable for 250 °C temperature rated for 2 hours. Fan outlet velocity shall be limited to maximum of 16 m/sec. Fan & Fan motor KW given below are for guideline & actual Dia / KW shall be as per manufacturer selection based on maximum 16 m/sec outlet velocity. Axial Fan shall be AMCA certified for Air and Sound performance in accordance to AMCA 210 and AMCA 300.

-

-

-

... More
Complete certified model appearing on AMCA web site shall be accepted. Complete Fan shall be tested and approved in accordance with "Power Ventilators for Smoke Control Systems" for 250 °C for 2 hours. Manufacturer shall furnish AMCA Test Certificate for air & sound performance along with fire test certificate (Latest) for each fan sourced from that particular factory. The noise level of axial fan shall be less than 80 dBa at a distance of 3.0 mt from the fan.

-

-

-

... More
10000 CFM, 900-1000 mm dia. for Parking Exhaust

2

-

180243.53

... More
15000 CFM, 900-1000 mm dia. for Smoke Exhaust

1

-

225511.15

... More
3500 CFM, 400-500 mm dia. for Liftwell Pressurization

3

-

91780.15

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 25 mm thick

100

-

896

... More
Supply, installation and testing of GI Louvers constructed with casing in 14 G & louvers in 18 G construction for supply / exhaust air application for ventilation fan including bird screen, fixing members, rain protector, free area of 55% etc as required to suit the site conditions.

4

-

8120

... More
Providing, supplying & Commission of Solar System Grid Based as mentioned below :

-

-

-

... More
• Solar PV module: 540WP Mono-PERC Half Cut Cell Solar Panels • Rooftop Ballast Type Structure •Grid Connect Solar Inverter (150kVA) •AC Distribution Board with breakers & Energy Meter-ACDB to LT Panel •1C x4sq mm DC Cable (standerd) •3.5C x25sq mm XLPE AI Armoured •Earthing kit, Earthing wire & GI earthstrip •MC-4 Cable couplers (Male & Female Pairs) •Lightening Arrestor •Installation Kit (Comm. Cable, Inverter Canopy etc.)

150

-

53000

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.

-

-

-

... More
The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glassetc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

409

-

8064

... More
Supply , Installation, and Comissioning RO PLANT CAPACITY - 500 LPH RECOVERY - 50% ELECTRICAL CONNECTION - 415 V, 3 PHASE, 50 HZ TDS - 100 PPM, cover all types of appplication & preceded by a proper pretreatment to avaoid membrane fouling by sediments, hardness, organic matter, bacteria, silica, metal oxides or even chlorine.

1

-

347875

... More
Supply of drinking online water cooler with bottle filler facility, made by stainless steel top and heavy duty galvanized steel frame. With cooling capacity, ADA Compliant, size 472 mm Depth X 447mm width, flexible bubbler guard , operated between 50 to 120 PSI, Chiller unit Suitable to R134a Refrigerant, Adjustable thermostat control, suitable for 220-230v/50-60 hz A/C Supply Complete with all accessories which include MD-CU29, which is an EPA registered antimicrobial copper that fights off microorganisms which include MRSA and e-coli.having Storage 80 Ltr,40 Ltr Cold And 40 Ltr Norms. The water Fountain shall possess NSF-USA, Green building, energy star saving certification, and to be placed at different location of buidling. As per Enginner Incharge- Make Oasis/ Filtrin/ Eureka Forbes / Voltas

5

-

46122.22

... More
Supply, Installation, Testing, Commissioning of 1 Nos. 100 AMP FP DUSK-DOWN TIMER WITH CONTACTOR as per direction of engineer in charge.

1

-

11450

... More
Supply, Installation, Testing, Commissioning of of Bollard Lights as per direction of engineer in charge

20

-

4283

... More
Supply, Installation, Testing, Commissioning of 1 Nos. 800 Amp FP Auto Transfer Switch as per direction of engineer in charge .

1

-

165600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.