State Agricultural Marketing Board Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

State Agricultural Marketing Board Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date2 Jul 2022
Closing Date20 Jul 2022
Tender Amount₹ 4,40,34,000 
Notes
Download

Costs

  • EMD

    ₹ 8,80,680
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000: 1:4:8 (1Cement :4 Course Sand :8 Graded stone aggregate 40 mm nominal size

772

-

2857

... More
Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000: 1:3:6 (1Cement :3 Course Sand :6 Graded stone aggregate 20 mm nominal size

47

-

3141

... More
Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000: 1:1.5:3 (1Cement :1.5 Course Sand :3 Graded stone aggregate 20 mm nominal size

13

-

4309

... More
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level.

910

-

118

... More
Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. All work up to plinth level IS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size)

204

-

4586

... More
Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. All work up to plinth level IS 456-2000: 1:1:2 (1-Cement:1-Coarse sand:2-graded stone aggregate 20 mm nominal size).

6

-

5266

... More
Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall IS 1597 (Part-I) 1992 in : Cement Mortar 1:6 (1-Cement:6-Sand).

704

-

2614

... More
Random Rubble stone masonary for superstructure above plinth level one storey height above 30 Cm. thick walls IS 1597 (Part-I) 1992 in : Cement Mortar 1:6 (1-Cement:6-Sand).

118

-

3087

... More
Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand.

205

-

519

... More
Random rubble dry stone Kharanja under floor.

215

-

683

... More
Earth work in excavation, including stacking/disposal of surplus material with all lifts and lead upto 495 metres, exclusive of compensation of earth [MoRTH specification : Clause 301 to 305] Mechanically by power shovel, including mechanical loading and carriage by tipper/dumper (6T capacity)

3294

-

93.45

... More
Carriage of Sand, bajri, ballast, stone, boulders, kankar & gravelly material includind loading & unloading For lead above 495mt up to 1000mt ) to be included in the respective item). Up to 5 Km. lead

3294

-

97.89

... More
Extra for laying earth as per specification for compaction in 200 mm thick loose layers and dressing [MoRTH Specification Clause 305.3.5]. BY MANUAL MEANS : When laying of earth in layers is done from stockpiles including breaking of clods and dressing with all lead and lift but excluding rolling and watering.

3014

-

24.15

... More
Extra for watering the earth to bring the earth upto required O.M.C excluding rolling

3014

-

13

... More
Extra for rolling to specification with Power Roller, 8-10 tonne when earth is at suitable moisture content with dry field density not less than 100 % of maximum dry density (Ordi-nary Procter test).excluding watering.

3014

-

19

... More
Provinding and laying of paver block as per IS 15658 : 2006 (Indian standerd for Precast concrete block for Paving -specification) and IRC :SP:63-2004(guidelines for the use of interlocking concrete blockPavement) M-40,80mm thick to be used in medium-traffic (Medium trafficis defind as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight , or an equivalent of 0.5 to 2.0 MSA for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc. Category 'B' denated only two side like I,Z,T shape etc. as per IRC SP 63:2004

5024

-

827

... More
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth , consolidating each deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr.

280

-

59

... More
Brick masonary in foundation and plinth with bricks of class designation 75 mm. IS 2212-1991 in : Cement Mortar 1:6 (1-Cement:6-coarse sand). Add extra over item No. 5.1 for brick work in superstructure up to third storey IS 1077-1986.

568

-

3797

... More
Half brick masonry in foundation & plinth using bricks of designation 75 with nominal hoop rainforsed (2 Nos. 6mm MS bar) at every fourth course in for hoop rainforcement 1Sqm. 6mm MS bar 2x2x1.00 = 4.00 Cement mortar 1:4 (1-Cement:4-coarse sand). Add extra over item No. 5.8 for half brick masonary in superstructure up to third story.

1119

-

531.3

... More
Reinforced cement concrete work in beams, suspended floors, roofs, girders having slopes up to 15o , landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases, up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good and joints excluding the cost of centering, shuttering and reinforcement IS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size).

743

-

4674

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding cost of centering shuttering and reinforcement IS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size).

101.8

-

4602

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding cost of centering shuttering and reinforcement IS 456-2000: 1:1:2 (1-Cement:1-coarse sand:2-graded stone aggregate 20 mm nominal size).

9

-

5507

... More
Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15o up to floor three level including curing, compaction with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement with 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size) IS 456, IS 2210-1988 :

4

-

4579

... More
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for: Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands , coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc.

1507

-

207.64

... More
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for: Columns, pillars, posts and struts etc.

1067.99

-

240

... More
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for: Walls (any thickness) including attached pilasters, buttresses, plinth and string course.

96.01

-

197.93

... More
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for: Arches, domes, vaults etc. up to 6 Mtr. span.

9.5

-

780

... More
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for: Add extra for shuttering in circular work in plan up to dia 10 m

96.01

-

21.74

... More
Add extra for doing centering and shuttering work for each subsequent storey.

1445

-

12.6

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Tremo Mechanically treated bars

101380

-

75

... More
Polished Blue Kota Stone flooring skirting, laid over 20 mm thick base of C.M. 1:4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete : For area of each slab up to 2001 to 5000 Sq. Cm : (A) 25 mm thick slab.

2507

-

921

... More
Add extra for mirror polishing on terrazzo / mosaic flooring : New surface

2507

-

104

... More
Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing of IS 3316-1974 : Jhunjhunu / Jalore (Red / Choclate Colour) Size above 3600 Cm2

118

-

2769

... More
Supplying and fixing machine cut and polished stone shelves, tands and sills in CM 1:3 with machine cut edges: Kota stone 25 to 30 mm thick.

157

-

505

... More
Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level up to 4.5 Mtr. height in R.S. Joists flats, tees, angles and channels.

1350

-

81

... More
Add for each wire line

3103

-

10.25

... More
Add for using galvanized barbed wire instead of black barbed wire.

3103

-

2.5

... More
Supply & fixing steel shutter (Almirah type) with 18 gauge steel border & steel shutter including locking arrangement and painting etc. complete fixed on wall with joint fast (iron clip)

301

-

2693

... More
Extra for providing edge moulding to 18 mm thick marble stone counters, vantities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work.

239

-

196

... More
Providing and fixing Ist quality standard White Ivory straight edge Glazed Tiles ISI marked [IS:13753] (Kajariya, Jhonson, Somani make etc. ) of size 450mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster).

1058

-

939

... More
Providing and fixing Ist quality MAT finished ceremic tile size 300x300mm confirming to IS : 13753 coloured tile expect white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler power (Untile or Roffe make) and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). Add extra for floor work due to extra cost of cement mortar 1:4 (1-Cement:4- fine sand) 20 mm thick.

275

-

958

... More
Providing and laying Chequerred plain cement concrete embossed specially manufactured non-slipping tiles of approved make 20 mm thick laid on 20 mm thick bed of cement mortar 1:6 jointed with neat cement slurry complete. Add extra for chequerred coloured plain cement concrete or specially manufactured non-slipping tiles of approved make 20 mm thick.

18

-

443

... More
Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish: 20 mm thick.

9378

-

181

... More
Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish : 12 mm thick. Add extra for plaster done over ceiling.

3077

-

165.6

... More
Providing and fixing pressed steel mitred door frames manufactured from commercial mild steel sheet of 1.25 mm (16 gauge) thickness including hinges jamb, lock jamb, head and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25 mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile 'C'

711

-

378

... More
Supplying and fixing of Steel windows made out (65x40mm), hollow metal pressed section of 1.25 mm thick sheet F4 & F7 standard rolled section conforming to IS 1038 with wholly openable shutter of 0.80 mm thick (out side & inside) opening C.R. sheet embossed panels, joints matted and flush welded with suitable hinges, steel lugs & screws with approved oxidized steel handles, fittings, peg stays (casement stays) etc. complete in all respect including providing 10 mm square M.S. bars 10 Cm. C/C and applying priming coat of red oxide paint.

180

-

2753

... More
Renewing glass panes, with puty and nails wherever necessary: 5.5 mm thick plain glass panes.

180

-

634.8

... More
Supply & Fixing fixed stainless steel wire gauge of 15 Mesh 27 gauge to the metal framed of rolled section by metal beading 20 x 3 with suitable revetting & screw not exceeding 150mm distance including removing of old wire gauge Jali as directed by Engineer in charge

180

-

1094

... More
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formaldehye resin, in glue both sides with approved steel fittings complete as per Annexure ‘A’ IS 2202 (Part I & II) 1999/1983. Decorative Teak veener one side 30 mm thick shutter

199

-

2153

... More
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets. 20 mm dia (Heavy type)

133

-

93

... More
Add extra for Flush doors For double leaf shutter

4

-

106

... More
Add extra For Internal teak wood lipping in 25mm depth in single leaf.

186.1

-

211

... More
Add extra For Internal teak wood lipping in 25 mm depth in Double leaf.

12

-

305.55

... More
Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20x10x2mm and brackets with flat iron diagonals 20x5mm, size with top and bottom rail of T-iron 40x40x6mm, with 40 mm dia steel pulleys / ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). IS 10521-1983. With 75 mm opening when closed. With 100 mm opening when closed.

8

-

3916.5

... More
Providing & fixing ms sheet single leaf door shutters in angle iron frame 35x35x5 mm suitablly diagonally braced with 25x3mm flat ironabove and below lock rail of size 50x5 mm beading extra includingall fittings, as per direction of engg. incharge but excluding coes of chokhats including two coats of anti corrastie red oxide primer panit. MS sheet 20 SWG

7

-

1673.7

... More
Making grooves as per design in plaster 10mm to 20mm wide.

10000

-

3

... More
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete

7229

-

75

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work including preparation of base with primer, & touching of existing putty, lippy complete in all respect

7229

-

73

... More
Painting with weather coat paint (Asin paint/ I.C.I./Berger or eq. ISI make paint) two or more coat to give an even shade on new work.

4169

-

54

... More
Painting with enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.

1337

-

45.48

... More
Supply and fixing in cement mortar welded hand railing made out of M.S. round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide.

500

-

88

... More
Grading roof water proofing treatment with : Cement concrete 1:2:4 (1-Cement:2-coarse sand :4-graded stone aggregate 20mm nominal size).

67

-

4327

... More
Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design.

700

-

30

... More
Providing and laying 20 to 25 mm size glazed tiles pieces for rooof treatment having colour and shade as approved by the Engineer incharge over 25 mm thick layer of cement mortar mix 1:4 with application of cement slurry including finishing of joints with ordinary cement and curing etc. complete in all respect. Washing with acid.

970

-

327.8

... More
Cement concrete flooring grade 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete IS 2571-1970 : 50 mm thick with 20 mm thick nominal size aggregate.

206

-

287

... More
Cement concrete flooring grade 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete IS 2571-1970 : 75 mm thick with 20 mm thick nominal size aggregate.

228

-

385

... More
Providing & laying vitrified dianomite floor tile, skirting, dedo, (Johnson, Euro, Naveen, Bell or equivalent etc.) size 600x600, 10 mm thick flooring over 20 mm thick bed mortar 1:4 mix with 2-3 mm thick joint to be filled with cementious grout or polymer based non shrink grout make Rofee/ Bell adhesive/ pidite etc of matching colour as per requirement of site.

329

-

1070

... More
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete above plinth level up to 4.5Mtr. height IS 1161-1998. Hot finished welded type tubes

3212

-

87.94

... More
P & F Plain Fiber glass sheet (FRP sheet fiber Reinforcement product sheet confirming to IS:12866-1989 having minimum thickness as below including fixing with nuts bolts hooks and bitumen washer etc. complete.) 2.0 mm thick (Wt.3.3 Kg./Mtr.Sq.)

161

-

1331

... More
Ornamental cement plaster in cement sand mortar 1:4, making Kangooras etc. as epr Jaipur practice.

290

-

375

... More
Providing and fixing Aluminum sheet 2 mm thick and 150 mm. Wide over expansion joint with fixing rowl plug and aluminum screws as per designs to match the colour shade of the distemper or wall treatment.

23

-

1582

... More
Supplying and providing of two components poly sulphide sealant containing solid contents, confirming to standard specification and approved compatible primer, for priming vertical faces prior to application of poly sulphide sealant including all labour charges for sealing of expansion joints after drill mixing of two components sealing compound. Cleaning and preparation of expansion joint using wire brush sand papering with emery paper and filing with suitable mechanical means. The work includes raking and cleaning of joints, sticking, debonding tape on bottom of joint, applying primer on edges, using masking tape on edges, providing of sealant and removal of masking tape immediately after providing sealant in joint. (A) To vertical joint between R.C.C. columns, bricks & stone masonary in size 40 mm width and 12 mm depth, including providing back up material (Thermocoal foam) if required.

61

-

537

... More
(B) To joints in flooring, as per drawing with first layer of poly sulphide sealant in size 20 mm width and 10 mm depth and then providing polyethylene foam back up rod 25 mm dia size and finally providing another layer of poly sulphide sealant in size 20 mm width and 10 mm depth over P.E. back up rod as per application procedure and direction of Engineer-in-charge.

40

-

505

... More
(C) To horizontal joints between beams masonary in size 40 mm width and 20 mm depth on top faces with pouring grade providing required back-up material (Thermocoal foam) complete.

39

-

840

... More
Dismantling stone rubble masonry including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. In Cement mortar.

488

-

519.6

... More
Dismantling roofing including ridges, hips, valleys and rafters etc. and stacking the within 50 meter lead of : Asbestos Sheet.

824

-

21.6

... More
Dismantling steel work in built up sections without dismembering including stacking within 50 meters lead.

69

-

82.8

... More
Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meter lead : Of area 3 Square meter and below.

98

-

42.78

... More
Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. In Cement mortar.

7.5

-

435.6

... More
Demolishing cement concrete including disposal of material within 50 meter lead : 1:4:8 or leaner mix.

91.6

-

318

... More
P & F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS:2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : Size 580x440 mm.

28

-

1864

... More
P & F European type white glazed vitreous china Ist quality W.C. pan (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor.

2

-

1709

... More
P & F water closet Seat Covers with brass hinges complete IS 2548-1996 : Solid PVC (ISI marked) grade-I White for EWC.

2

-

398

... More
P&F Jet spray for water closet with C.P. copper tube flange of approved make

2

-

17.6

... More
P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall : (A) 460 dia for counter top.

12

-

1894

... More
(B) Size 550 mm x 400 mm

6

-

1700

... More
P&F looking mirrors with PVC frame of approved (atul/equivalent) Size 500x400mm

22

-

278

... More
P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : PVC with PVC bend as per IS : 7231

2

-

1288

... More
P & F Flush Cock/Flush Valve (IS:9758 Mark) or WC of approved quality make : C.P. brass push type 15 mm nominal bore.

28

-

225.5

... More
P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection with 37 Cm. long thread and nut.

20

-

471

... More
P & F Stop cock (IS:8931 Mark) superior quality & of approved make : C.P. Brass Concealed Stop Cock 15 mm.

20

-

580

... More
P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : (A) C.P. Brass bib cock, 15 mm nominal bore.

94

-

470

... More
P&F towel rail or ring of approved quality /make: C.P. brass towel rail elbow type with concealed screws size 600mm (heavy duty)

16

-

506

... More
P & F CPVC Pipes in SDR 11 (Internal work) with CPVC fittings (IS:15778 Mark) including cutting and making good the walls and floors : (A) Exposed on Wall (i) 20mm dia

250

-

131

... More
(ii) 25mm dia

200

-

174

... More
P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant (A) 75mm dia

80

-

165

... More
(B) 110mm dia

350

-

253

... More
P&F Grating of approved quality/ make Stainless steel sheet size 125mm dia

50

-

52.8

... More
P&F Soap dish or tray of approved quality/ make. C.P. brass heavy and superior quality

20

-

104.5

... More
P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design. (A) 1000 litres capacity.

10

-

7150

... More
Construction of Open Surface Drain with 112 mm thick brick masonary in CM 1:4, 110mm thick base concrete 1:5:10, 37mm thick M-15 grade C.C. flooring, 12 mm 1:4 cement plaster on all exposed face of walls including top surface excavation & disposal of earth complete as per approved design/drawing: 250mm drain 300mm av. Depth

200

-

440

... More
P & F kitchen & Lab Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up to floor level complete including cutting and making good the wall & floor IS 771 (Part-II) -1985. WVC Lab Sink (IS:2556 Mark) size 530x430x180 mm.

4

-

2170

... More
P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete : Brass wt. 400 gm, 15 mm.

10

-

220

... More
P & F Full-way valve (IS:778 Mark) or wheel valve of approved make : (A) Gun-metal 25 mm nominal bore.

10

-

404

... More
P & F 15 mm. Dia Connection pipe of approved quality/make: PVC pipe with C.P. Brass nuts up to length 600 mm.

20

-

61

... More
P&F Bath shower of approved quality/ make . C.P. brass of heavy & superior quality 150mm.

1

-

319

... More
Construction of manhole in all type of soil inner size 90 X 60 Cm. thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring,making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C.flooring , 25 Kg. CI cover with frame of 40mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth upto 0.5mtr Add extra over item 3.21.1 for every addl. 0.10mtr depth above 0.5m depth.

25

-

3767.5

... More
Construction of chamber in all type of soil with 300 mm thick masonry in Cm 1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size size 450 x 450mm upto depth of 0.5m & 15Kg CI cover with frame

20

-

1127.5

... More
Construction of soakage well in all type of soil 300 mm thick dry masonry top and bottom 300 mm course in CM 1:6, 80 mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring, earth work complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 300 Cm. dia outside & 300 Cm. depth.

3

-

10560

... More
P & F Sink Cocks of superior quality & approved made: C.P. Sink cock swinging spout 15 mm.

4

-

458

... More
Construction of septic tank in all type sof soil with 40cm thick masonry in CM 1:6 15cm thick CC bed of 1:5:10 M-15 grade CC flooring & over stone slab covering, 80mm thick slab jointing of slab in CM 1:3, Ralthal, Kharanja, 50mm thick stone partiton walls, 20mm thick plaster in CM 1:6 finished with neat floating cement, 4Nos C.I. foot rests of approved design, two No. 450mm dia 25Kg each C.I. cover with frame, earth work etc. complete as per approed drawing incl. disposal of surplus earth wtihin a lead of 50mtr. IS 2470 (Part-I) 1985. Size 400x140x150cm (for 50users)

3

-

33275

... More
[PART "B" ELECTRIC WORK] Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
(A) Short point (up to 3 mtr.)

124

-

238

... More
Medium point (up to 6 mtr.)

280

-

360

... More
Long point (up to 10 mtr..)

283

-

465

... More
Wiring of twin control light point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,2 nos. 18 SWG Hot Dipped Galvanized Modular Box with earth terminal ,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / lamp holder/ 3 pin connector ,Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Long point (up to 10 mtr.)

12

-

852

... More
Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles, 18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modular switch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
On board

322

-

246

... More
These rates are for recess wiring, rates shall be decreased for point wiring / piping work by 10 % for surface wiring in place of recess wiring . This note is applicabe only If already mensioned in Schedule "G'' at the time of tender.

-

-

-

... More
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
MMS ( IS:9537 P - III ) PVC conduit

-

-

-

200

-

30

5260

-

36

450

-

110

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( 10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
(a) 2 x 1.5 sq.mm

200

-

24

... More
(b) 1 x 2.5 sq.mm

2180

-

19

... More
(c) 2 x 2.5 sq. mm. + 1x1.5sqmm

5936

-

50

... More
(d) 3 x 2.5 sq.mm

40

-

57

... More
(e) 3 x 4 sq. mm.

27.9

-

78

... More
(f) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.

3600

-

71

... More
(g) 3 x 6.0 sq. mm.

30

-

120

... More
(h) 2 x 6 sq.mm + 1 x 2.5 sq.mm

250

-

100

... More
(i) 2 x 10.0 sq.mm

100

-

138

... More
(j) 4 x 10.0 sq.mm

300

-

274

... More
(k) 1 x 10.0 sq.mm

300

-

70

... More
Providing & Fixing in position frame made out of M.S. angle (riveted or welded) as per IS: 2062-2011 finished with two coats of red oxide and two coats of enamel paint including cutting, welding, holes etc. of following sizes as required. All drawing as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
50mm x 50mm x 6mm

5.2

-

347

... More
Providing & Fixing of P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100 mm dia.

186

-

7

... More
P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

186

-

91

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single pole MCB

-

-

-

... More
6 A to 32 A rating

273

-

142

... More
Double pole MCB

-

-

-

... More
50-63 A rating

9

-

667

... More
Triple pole MCB

-

-

-

... More
80 A rating

10

-

3242

... More
6 A to 32 A rating

4

-

636

... More
50-63 A rating

4

-

956

... More
Providing & Fixing of 240/415 V isolator as per PWD specification for electrical Works with ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. , label holding facility , IP 20 contact protection and fitted with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Four pole Isolator

-

-

-

... More
80 A/ 100 A rating

15

-

755

... More
Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
IP-43 Double door (Three phase)

-

-

-

... More
6 Way ( 18 O/G + 8 I/C )

15

-

1917

... More
Providing & Fixing of IK 09 rating recessed/surface mounting heavy duty Vertical type sheet steel 1.6 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3 with provision of incomer suitable for MCCB and SP / TP MCB as outgoing , phosphatised ,powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, testing etc. as required complete in all respect.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
IP 43- Double door with Provision of Incomer MCCB 100 / 125/160 A Rating

-

-

-

10

-

4527

... More
Providing & Fixing of ISI marked (IS:2268-1994) single / multi tone electronic call bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

-

203

... More
Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
32 Amp. 2 Module switch With Led Indicator

10

-

266

... More
Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25 Amp. 2 Module Socket

10

-

162

... More
Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

-

-

-

... More
5 step fan regulator 100 watt 2 Module

186

-

310

... More
Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Blanking plate

50

-

15

... More
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

144

-

397

... More
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c),(d) below:-

-

-

-

... More
(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure

-

-

-

... More
(b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear

-

-

-

... More
[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar.

-

-

-

... More
(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

6.84

-

3443

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Electrolytic grade Aluminium bus bar 6010 grade

5.18

-

445

... More
Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. Field-programmable high and low threshold values, meter shall compliance of IS 13875 & IEC 61236. as required. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Digital type

2

-

1053

... More
Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better , Measuring current range 50 mA to 6 A, with Field-programmable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required. compliant to IS 13875, & IEC 61326. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Digital type Confirming to IEC 62053-21

-

-

-

... More
Below 500 A

2

-

1039

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
C T Class 1, Ratio upto 150/5, Burden 5 VA

6

-

355

... More
Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

-

255

... More
Providing & Fixing of ISO certified company made CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

-

302

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

12

-

127

... More
Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) as per PWD specification for electrical Works, ISI marked IS:13340-41 / conforming to IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.35 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 250 times of rated current, including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Heavy duty Three phase 480 V, 50 Hz cylindrical capacitor (Bank)

60

-

335

... More
Providing & Fixing of IP54 on front microprocessor based three phase sensing power factor correction relay , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, VTHD, ITHD, metering facility as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
12 to 14 stage

1

-

15573

... More
Providing & Fixing of ISO certified company made Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
10 AMP

2

-

254

... More
32 AMP

3

-

295

... More
63 AMP

2

-

429

... More
Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
up to 6 kVar

2

-

1199

... More
10 kVar

3

-

1517

... More
20.0 kVar

2

-

2593

... More
Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3 pole Power contactors with following AC 3 Rating

-

-

-

... More
140 Amp

1

-

12211

... More
Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
One day & week reserve (mechanical type )

1

-

2546

... More
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
With Thermal Magnetic release

-

-

-

... More
up to 100 Amp, 25 kA, adjustable O/L & fixed S/C setting, lcs = 100 % /cu

10

-

5465

... More
250Amo 35 kA adiustable OI L & fixed S/ C settin11. lcs - 100 % lcu

3

-

16634

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:-

-

-

-

... More
(a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I

-

-

-

... More
(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .

-

-

-

... More
(c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Armoured Cable

-

-

-

... More
95.0 Sq. mm 4 core

200

-

426

... More
10.0 Sq. mm 2 core

300

-

81

... More
10.0 Sq. mm 4 core

150

-

109

... More
Supplying and making end termination with heavy aluminium lugs Pin / ring type (as per IS 8309 -1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc of following size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
95.0 Sq.mm

32

-

23

... More
Providing & Laying of 25 cm thick layer of river sand to cover of existing cable in 30cmx75cm size cable trench with levelling and making symmetric 25 mm thick layer in complete running length of trench as required.

150

-

54

... More
Providing & covering of existing cable lying in existing trench by IInd class bricks/ Stone slab of minimum 32mm thick and 250 mm wide in complete running length of trench complete as required.

150

-

44

... More
Labour charges for Excavation of 30cmx75cm size trench in loose soil including refilling of excavated earth,compaction of earth, making good the same complete as required .

150

-

59

... More
SITC of chemical Gel earthing system of Dual Pipe Technology made of with "B" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :-

-

-

-

... More
(a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second .

-

-

-

... More
(b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts

-

-

-

... More
©Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.

-

-

-

... More
(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.

-

-

-

... More
(e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell

-

-

-

... More
GI pipe 2000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip

10

-

4063

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
8 SWG copper Wire

150

-

81

... More
Supply & Laying following size' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100 mm dia.

6

-

837

... More
Making of hole in wall (brick/stone) of required size for housing exhaust fan and making good the same, with cement plaster as required of following size:

-

-

-

... More
Up to 457 mm size

36

-

282

... More
Fixing of fresh air fan/exhaust fan up to size of 300 mm on ply/ poly board of 6.0 mm in existing window frame including cost of ply, cutting of hole in ply. Nut bolts etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

36

-

134

... More
Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V- 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
1200 mm Sweep BEE 1 Star rated (service value =4.0 to 4.5 )

184

-

1362

... More
Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
300 mm sweep(900/1400 RPM)

36

-

2252

... More
Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

110.4

-

132

... More
Numbering of ceiling fans/ fixtures with approved enamel paint etc as reqd

425

-

20

... More
Providing & Fixing of ISO Certified company made ISI marked (IS:2082) of 5 star rated vertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloy connection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
15 Ltr.

28

-

7761

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% ,p.f.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.

-

-

-

... More
OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.

-

-

-

... More
4' LED Tube shape fixture 18/20 W (Polycarbonate Base)

241

-

228

... More
Providing & fixing of lP20 LED Recessed/ Surface Mounted, Round./ Sqaure. Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency 85% and in compliance to IEC standards. System Lumen efficacy min. 100 Im/watt, THD 10 % ,p.f.0.95, CRI 80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends , CCT 3000"K / 4000"K / 5700°K /6000"K/6S00"K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.) . Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate/ Report from OEM shall be submitted. All as per pre approved by engineer in charge. foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.

-

-

-

... More
Surface Mounting

-

-

-

... More
LED Downlight 18/20W

6

-

612

... More
Providing & Fixing of IP20 LED Surface/ Recessed/ suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity/transmisity,!JV-stabilized Non-l yellowish diffuser for uniform light distribution, High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture) . System Lumen efficacy min. 100 Im/watt ,THD 10 % , p.f.~0.95,CRI 80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000"K/6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate/ Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.

-

-

-

... More
Susoended Mounting/Surface Moutning

-

-

-

... More
36W-LED light fixture 2'x2' with acrylic/ prlsmatic front cover.

84

-

2032

... More
Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI 70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.

-

-

-

... More
OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.

-

-

-

... More
18/20 Watt

103

-

167

... More
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy =120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.

-

-

-

... More
OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
LED Street Light fixture 120 Watt

10

-

9321

... More
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
40 mm Dia.

11

-

290

... More
Supply Installation testing & Commissioning of Radial / mixed flow ISI marked water filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034:2018 and IS 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 with required accessories including making connection suitable for Bore well. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.

-

-

-

... More
15.0 HP, 3-Ø, (80 - 123)Mtr, (465-305) LPM

1

-

58589

... More
Supply Installation testing & Commissioning of ISO certified manufacturer made Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, . Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
2.0 HP, 3-Ø, (6-27)Mtr, (425-100) LPM

1

-

14742

... More
Supply Installation testing & Commissioning of ISO certified company made DOL/Star-Delta Starter panel made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
For Three phase Submersible / Mono block pump

-

-

-

... More
3.0 HP to 10.0 HP ( Star / Delta starter )

2

-

6614

... More
Supplying and Laying ISI marked P.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( 10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6.0 Sq.mm 3 core flat / Round

400

-

184

... More
Supply , Installation, Testing and Comissioning of ISO certified company made self contained drinking water coolar with BEE Rated energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)body and tank , stainless steel water tray,minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs

4

-

55192

... More
Supply and Installation of Box type EU13 Hepa Filter of 99.997% efficiency down to 0.3 micron particle size installed in zero leakage Aluminium frame as per ISO 14644-1 clean room including sealing and packing material cost like silicon and hardware cost and Labour cost. NABL accredeated / appropriated lab testing reports with OEM certificate must submitted to engineer in charge. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
150 mm thick

4

-

18779

... More
Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

15

-

4920

... More
S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026- 1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
160KVA

1

-

220178

... More
Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications:- All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
DP : Double pole structure on 2 no ISMB 150 x 100 mm, 10 mtr high using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required.

-

-

-

... More
GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation.

-

-

-

... More
DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators

-

-

-

... More
LA: 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required.

-

-

-

... More
JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’

1

-

61855

... More
Supply and fixing of piller box as per DISCOM / PWD specifications made of 2 mm thick powder coated CRCA sheet of 415 volts 3 phase 4 wire triple pole and neutral type, complete in all respect as required. Including knife switch of 400 amp. rating , HRC fuses with copper one piece U contacts base, brass studs and nuts, copper busbar for main and interconnection, MS angle frame of 50 x 50 x 6 mm grouted with C.C. of M-10 grade to achieve the height of 1.5 feet above the road level suitable for four outgoing. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

-

38829

... More
Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.)

-

-

-

... More
9 Mtr.

9

-

19294

... More
Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:-

-

-

-

... More
(a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I

-

-

-

... More
(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures

-

-

-

... More
(c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3 core 120.0 Sq.mm

150

-

738

... More
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
11 KV End Termination Kit Outdoor type

-

-

-

... More
3 core 120/150/185 Sq.mm

6

-

4920

... More
Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i)Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set (To be supplied by DISCOMs), (iii)TT Block, (iv) 6mm Bakelite sheet on all sides, (V) 3/6 core copper cable for interconnections etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

-

20663



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.