Water Supply And Sanitation Department Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Water Supply And Sanitation Department - WSS Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date5 Mar 2024
Closing Date15 Oct 2024
Tender Amount₹ 49,75,182 
Notes
Download

Costs

  • EMD

    ₹ 99,504
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 5,871

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS Code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.

-

-

-

... More
150mm nominal diameter (weight 21.6 Kg per meter) 5.4mm thickness

56

-

-

... More
Supplying, fixing, lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest with ISI Marked dully welded with suitable grade S.S welding electrode to lower the strainer into Tubewell bore.

-

-

-

... More
150mm internal diameter (slot size 0.75mm) 5.00 mm thickness (As per A & C Slip)

10

-

-

... More
Supplying, fixing lowering of stainless steel socket as per IS: 8110-2000 or latest ISI Marked dully welded with suitable grade S.S welding electrode to lower the strainer into Tubewell Bore complete in all respects.

-

-

-

... More
(150mm) i/d

2

-

-

... More
Supplying and fixing of bail plug of MS pipe complete with inverted u-hock attached to the bottom plug complete in all respects (150mm) i/d weight 21.6 kg p/m) 5.40 mm Thick.

4

-

-

... More
Supplying and Fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.

5

-

-

... More
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. 150mm internal diameter

1

-

-

... More
Supplying & fixing of M.S Clamp of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.

1

-

-

... More
Supplying, lowering & fixing of M.S Special Socket to connect S.S. Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. 150mm internal diameter

4

-

-

... More
Supplying at site Wooden Box of suitable size with Lid & locking arrangement for preserving strata sample collected from the bore.

1

-

-

... More
Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe)

20.32

-

-

... More
Development and stabilizing of the tube well with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.

-

-

-

... More
Capacity of Air compressor 300 cfm at 250 PSI

20

-

-

... More
Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge

15

-

-

... More
Collection of Water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)

3

-

-

... More
Testing of water sample for heavy metal testing from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc)

3

-

-

... More
Provision for Sanitary Clay seal (as per BIS Code IS 2800:2019) including sterilization of tubewell

1

-

-

... More
PUMP CHAMBER Construction of Pump Chamber size 3.05 x 3.70m with W.C, with gravel pit & electric wiring as per DWSS standard design & analysis, complete in all respects.

1

-

-

... More
Providing & Installing Testing & Commissioning of one No. Electrically driven Submersible Pumping set of reputed make capable of delivering 141 LPM against a head of 42 mtr head along-with electric panel board consisting of electric appliandiv.gsp such as automatic Starter, Main Switch. Volt Meter, Ampere Meter, ELCB, Shunt Capacitor, Single Phase Preventer, Indicating Lamps, MVB/MCCBs etc. including M.S. Column Pipe of suitable size 36 m (in 3 m Lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (of reputed make) complete in all respects. As per ISI 1239-2004

-

-

-

... More
Rate of Motor with Pump

1

-

-

... More
Panel Board

1

-

-

... More
Submersible cable Size 4.00mm2

52

-

-

... More
Column Pipe (G.I) 80 mm i/d

18.5

-

-

... More
C.I.FITTING INSIDE PUMP CHAMBER Providing & Installing 100 mm dia delivery main (from Tube-well to duck foot bend including cost of C.I.D/F Pipes, D/F Sluice Valves, D/F Non Return Valve & Specials as C.I. Bends, Tail Piece Tees, Pressure gauge, Air Valve,,V notch haudi etc. inside the Pump chamber as per DWSS standard design and analysis complete in all respects.

1

-

-

... More
Disinfection Unit:Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution/ sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter.

1

-

-

... More
RCC OHSR Construction of one No. RCC OHSR 25000 Ltrs capacity having height of 17.20 m upto FSL 15.50 m upto sill from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing D.I. K-9 D/F expansion joints latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I/D.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI double flanged pressure pipes DI K-9 horizontally as per IS 8329-2000 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of sail is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling, including overflow scower haudi complete in all respects.

1

-

-

... More
uPVC RISING MAIN Providing, Fixing, laying, jointing, cutting & testing of uPVC Pipes & Specials (10 kg./cm2) including cost of excavation complete in all respects as per DWSS standard analysis.

-

-

-

... More
110 mm o/d (mechanical)

40

-

-

... More
Sluice Valve & Sluice Valve Chambers Providing & fixing C.I D/F Sluice Valves ISI marked 14846-2000, including cost of tail piece, rubber joint, gland dori, Nuts, bolts & accessories, complete in all respects as per DWSS standard analysis.

-

-

-

... More
100 mm Nominal Bore (N.B.)

2

-

-

... More
Construction of brick masonry sluice valve chamber size 0.90m x 0.90m as per DWSS standard Drawing & Analysis.

2

-

-

... More
DEVELOPMENT OF WATER WORKS SITE. Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 9.34 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects as per DWSS standard Drawing and analysis.

207

-

-

... More
Providing & Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4mm dia fencing pole size at bottom 4"x4", size top 3" x 4", Length 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects.

30

-

-

... More
Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm as per DWSS standard Drawing and analysis.

30

-

-

... More
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per DWSS standard Drawing & Analysis.

4

-

-

... More
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22 m x 1.37 m as per DWSS standard Drawing and analysis.

1

-

-

... More
Construction of Foot Path with masonry toe wall & earth filling and Cement Concrete 1:8:16 with 40 mm gauge stone aggregate, 40 mm thick cement concrete topping 1:2:4, inside water works as per DWSS standard Drawing and analysis.

30

-

-

... More
Providing & fixing MS sign Board as per DWSS standard design and analysis.

1

-

-

... More
Providing, Fixing, laying, jointing, cutting & testing of uPVC Pipes & Specials (6 kg./cm2) including cost of excavation complete in all respects as per DWSS standard analysis.

-

-

-

... More
Excavation with JCB (having gravel upto 40%)

-

-

-

... More
uPVC Pipe 63 mm o/d

44

-

-

... More
uPVC Pipe 90 mm o/d

521

-

-

... More
uPVC Pipe 110 mm o/d

37

-

-

... More
Excavation with Manually (having gravel upto 40%)

-

-

-

... More
uPVC Pipe 63 mm o/d

953

-

-

... More
uPVC Pipe 75 mm o/d

213

-

-

... More
uPVC Pipe 110 mm o/d

20

-

-

... More
Making Connection with existing pipe line including cutting cost of D-Joint, labour for fixing specials excavation bailing out etc.

4

-

-

... More
Providing & fixing C.I D/F S.V. including cost of tail piece, rubber insertion, gland dori, Nut bolts & accessories complete in all respects. ISI marked/Kirloskar/ Audco or equivalent make)

-

-

-

... More
100mm i/d

2

-

-

... More
80mm i/d

6

-

-

... More
Construction of masonry sluice valve chamber size 0.60m x 0.60m as per DWSS standard Drawing & Analysis.

6

-

-

... More
Construction of masonry sluice valve chamber size 0.90m x 0.90m as per DWSS standard Drawing & Analysis.

2

-

-

... More
Contractor shall be quote rates only for dismantling of mettaled road & back filling with excavated earth fully compacted the restoration of the mettaled road to its original condition will be done by the concerned department i.e. PWD (B&R) PMB/Panchayati Raj)

-

-

-

... More
90mm o/d 50 No road cut x 4 mtr = 200 mtr

200

-

-

... More
Dismantling and restoration of Cement Concrete Road complete in all respect as per DWSS standard approved analysis.

-

-

-

... More
63mm o/d

635

-

-

... More
75mm o/d

213

-

-

... More
Dismantling and restoration brick paving complete in all respect as per DWSS standard approved analysis.

-

-

-

... More
63mm o/d

131

-

-

... More
90mm o/d

170

-

-

... More
Dismantling and restoration of interlocking tile complete in all respect as per DWSS standard approved analysis.

-

-

-

... More
63mm o/d

192

-

-

... More
House water connection (Excavation 40% Gravel) Providing Proposed water connection to house hold up to wall with providing laying, jointing, testing G.I. pipe lines 15mm i/d =2.5 mtr B class as per CSR 28.36(A) (Above G.L.) Providing and fixing MDPE pipe 15mm i/d with specials 2.00 mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow etc cutting, threading and testing trenchs in the ground and ISI 15mm i/d GM ferrule s per IS 2692 and 3" i/d clamp with C.I. bib cock 15 mm i/d as per IS 210 with stainless steel spindle of approved make as per CSR 30.65(b)

114

-

-

... More
Bulk Meter

-

-

-

... More
Providing & Installing of Suitable size mechnical Bulk Meter inside water works including rubber jain, Nut Bolts, Cutting and threading, piece for fixing Bulk Meter including carriage complete in all respects as per IS code 2373-1981

1

-

-

... More
Environmental Management Charges

-

-

-

... More
Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil.

202

-

-

... More
Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm, yard manure @30% of pit volume and insecticide for termite control

6

-

-

... More
Supplying and planting permanent trees in prepared pits and watering

5

-

-

... More
Planting seedings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedings at 20cm distance from plant to plant and row to row

4

-

-

... More
Painting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row

6

-

-

... More
Providing for one way stand post with Khura complete in all respects.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.