Water Supply And Sanitation Department Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Water Supply And Sanitation Department - WSS Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date15 Mar 2024
Closing Date3 Jul 2024
Tender Amount₹ 67,24,753 
Notes
Download

Costs

  • EMD

    ₹ 1,34,495
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 5,900

Summary

Bifurcation Of Water Supply Scheme In Village Kulgran 1 No From Existing Water Supply Scheme Dayapur Kulgran

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.

-

-

-

... More
200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness

91

340416

3740.84

... More
Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore.

-

-

-

... More
200mm Steel Strainer (slot size 0.75mm) 6.30 mm thickness

10

96116

9611.61

... More
Supplying and fixing of bail plug of M.S. Pipe complete with inverted U-hook attached to the bottom plug complete in all respects.

-

-

-

... More
200mm internal diameter (Weight 33.6 kg per meter) 6.4 mm thickness.

4

14140

3535

... More
Supplying & fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.

5

1561

312.3

... More
Supplying and fixing of well cap having threads to fix on housing pipe complete in all respects.

-

-

-

... More
200mm internal diameter

1

788

788.96

... More
Supplying and fixing M.S. Clamps of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing Pipe including the cost Nut & Bolts of Suitable size complete in all respects.

1

2822

2822.48

... More
Supplying, fixing and lowering of stainless steel socket as per IS 8110: 2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respects.

-

-

-

... More
200mm internal diameter

4

20702

5175.71

... More
Supplying at site wooden box of suitable size with Lid & lockign arrangement for preserving strata sample collected from the bore.

1

614

614.77

... More
Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipe assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe)

8.1

14242

1758.29

... More
Development and stabilizing of the tubewell with Air compressor or required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.

-

-

-

... More
Capacity of Air Compressor 300 cfm at 250 PSI

10

38604

3860.47

... More
Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.

8

16790

2098.78

... More
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)

1

324

324.92

... More
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Uranium etc.)

1

6579

6579.58

... More
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect

1

18366

18366.12

... More
Supplying at site Tibba sand etc. including pouring and packing in the annular space between the pipes assembly and the bore above clay seal complete in all respect.

1.51

679

450

... More
Providing & Fixing Clay seal in graval pack minimum 3 Mtr.(As per BIS Code 2800:2019)

3

3000

1000

... More
Providing & Fixing Sanitery Seal (As per BIS Code 2800:2019)

1

1000

1000

... More
Provision for Sterilisation of tubewell with sodium hypochorlide/ chlorination of well as per IS code 2800: 2019 complete job. The well shall be disinfected or sterilized as per IS code 2800:2019 or latest, after the development by pump and before the final test. All wells regardless of the use should be sterilized on completion to prevent or retard the growth of corrosion or Incrustation fostering organisms. This should be done by introducing chlorine into the water in the well and immediate aquifer surrounding the well The volume of water in the screen and casing should be estimated and sufficient chlorine added to yield for water with chlorination of 1000 ppm. The solution should be poured into the well and thoroughly mixed in the well by surging with pump. The solution should remain in the well for at leaset 6 hours during which it should be surged at about 2 h interval. After expiration of contact time, the well should be pumped initially back into the well for abour 30 minute and late to waste until there is little of no odour or taste of chlorine in the discharged water. IT has been found that using hypochlorite is of 10% concentration, the requirement of hypochlorite is 10 litre for every cubic meter of water in the well to produce

1

2000

2000

... More
OHSR

-

-

-

... More
Construction of One No. RCC OHSR of 50000 ltr. Capacity with sill level not less than 17 mtr. and FSL not to be less than 20 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces Providing and applying integral crystalling slurry of hydrophillic in nature for water proofing management etc. for vertical and horizontal surfaces and swellable typ water stop tap. complete in all respect. Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. ( All including carraige )

1

2043000

2043000

... More
PIPE LINE FOR PUMPING MAIN

-

-

-

... More
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation. (Manually)

-

-

-

... More
110mm o/d pipe of 10 Kgf. / sqcm

50

44000

880

... More
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)

-

-

-

... More
100 mm I/d

2

12124

6062.37

... More
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete.

66

4790

72.58

... More
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (each of size 0.9m x 0.9m)

2

17015

8507.58

... More
PUMPING MACHINERY

-

-

-

... More
Providing, installing, testing and commissioning of 1 no. Electrically driven pumping set of reputed make, capable of deleviring 244 lpm against a head of 52 mt . Complete in all respects.

1

39580

39580

... More
Supplying lowering of 65 mm dia GI pipe as per IS 1239 (B - class) premim make such (as Jindal Hisar) including cost of specials such as tees, bends, sockets elbow etc, cutting, treading and testing in trenches in the ground. Complete in all respects

28

25465

909.49

... More
Providing and fixing of submerssible of mm 2.50mm² core cable, complete in all respect

71

7455

105

... More
Providing installing, testing and commissioning of 1 no. control panel with closed transition star delta with enclosure consisting of electrical appliances such as contactor, furses, MCCB's over load relays, isolator switches wiring and connnections. Complete in all respect.

1

22000

22000

... More
C.I FITTING INSIDE PUMP CHAMBER

-

-

-

... More
Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects.

1

48700

48700

... More
Construction of Gravel Pit outside the Pump Chamber. (0.90m Dia.) as per standard design & drawings of public health department.

1

18490

18490.22

... More
DISTRIBUTION SYSYTEM

-

-

-

... More
Providing, Stringing out PVC pipes as per ISI-4985 (ISI marked with prior approval of Engineer in charge) casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including excavation & specials complete as per specifications for less than 3 mtr street width. Complete in all respect (BY MANUAL MEANS) Imp. Note:- Excavation item no. 28.1 (ii) (For Ordinary soil having gravel upto 40%) is taken as the area of village falls in KANDI AREA.(6kgf/sqcm)

-

-

-

... More
PVC pipe 63 mm o/d

983

293917

299

... More
Providing, Stringing out PVC pipes as per ISI-4985 (ISI marked with prior approval of Engineer in charge) casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including excavation & specials complete as per specifications for less than 3 mtr street width. Complete in all respect (BY Mechanically MEANS) Imp. Note:- Excavation item no. 28.1 (ii) (For Ordinary soil having gravel upto 40%) is taken as the area of village falls in KANDI AREA.(6kgf/sqcm)

-

-

-

... More
PVC pipe 63 mm o/d

295

71685

243

... More
PVC pipe 90 mm o/d

1398

555006

397

... More
PVC pipe 110 mm o/d

786

422868

538

... More
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.

80

1600

20

... More
Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects

741

409773

553

... More
Dismantling & Refixing of Interlocking Tile 60 mm thick factory made cement concrete interlocking Paving blocks of M- 35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of engineer-in- Charge.

134

44622

333

... More
Dismantling of mettalic road with bitumainous course 50mm to 75 mm thick CC 1:8:16. Complete in all respect as per instructions / directions issued by EIC

2171

195390

90

... More
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)

-

-

-

... More
80 mm I/d Sluice Valves flanged

2

8939

4469.84

... More
100mm i/d Sluice Valves flanged

2

12124

6062.37

... More
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete.

132

9580

72.58

... More
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
0.60mm x 0.60mm

2

11543

5771.75

... More
Size 0.9 m. x 0.9 m.

2

17015

8507.58

... More
Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation, stringing and jointing of pipe upto 160mm complete

58

59448

1024.98

... More
CHLORINATOR & DISINFECTION UNIT

-

-

-

... More
Prov. Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator ,suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kgf/cm², and suction lift not less than 1.5 m, as per DWSS. standard specifications.

1

16000

16000

... More
HOUSE HOLD CONNECTION

-

-

-

... More
Providing household connection laying, jointing, fixing, testing MDPE pipes (As approved by Engineer-in-charge), including cost of excavation,C.I bib cock as per IS:210 with stainless steel spindle 20mm o/d MDPE/ GI pipe 4.50 mtr. (2.0 mtr. MDPE & 2.50 mtr. G.I, Vertical Pipe) 3" i/d uPVC clamps, GM ferrule ISI marked connection of 15mm i/d ferrule medium, special such as tees, bends, sockets, elbows, nipples (100mm & 150mm) union couplings, G.I Hooks etc. and Gun metal peet valve (heavy pattern) with hand wheels on MDPE pipe line laid in the ground or inside building, cutting, treading. making hole in the wall complete in all respect.

70

132300

1890

... More
Development of Water Works

-

-

-

... More
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects

370.68

7413

20

... More
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects

43

23865

555

... More
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm

30

3960

132

... More
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects

4

30360

7590

... More
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr

1

30900

30900

... More
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works

25

65875

2635

... More
Providing & fixing MS Sign Board as per standard size of DWSS

1

7100

7100

... More
Construction of toe wall around the water works site

120

133200

1110

... More
PUMP CHAMBER WITH TOILET

-

-

-

... More
Construciton of pump chamber having 3.05x3.70 mtr. plinth area including cost of electric wiring & sanitary installation as per standard design complete in all respect including construction of toilet

1

379885

379885

... More
Carriage of material

-

-

-

... More
Extra for Carriage of Fine & Course aggregate i.e. Sand & Bajri from query to water works site Lead 40 Km.

-

-

-

... More
Sand & BAJRI

65.46

20895

319.21

... More
Environment Charges

-

-

-

... More
Grassing of grounds with doob grass including uprooting rank vegetation and weeds by digging the area to a depth of 15 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer, rough dressing and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, planting grass roots in rows 10 cm apart in both directions, watering, weeding and maintenance till turf is formed

225

9007

40.03

... More
Planting hedge including digging of trench 60 cm wide to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 30 cm distance from plant to plant in two rows.

50

8796

175.93

... More
Supplying and planting permanent trees in prepared pits and watering

10

1801

180.15

... More
Supplying and planting permanent shrubs in prepared pits and watering

10

695

69.53

... More
Operation and maintenance

-

-

-

... More
Operation and maintenance is carried out by the contracting agency for 3 months ( 90 days) having Provision of Operating Staff Pump Operator –Cum Chowkider 1 No,Provision of Bleaching powder or soldium chlorite for disinfection of water etc. Complete job.

1

42753

42753.84



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.