Water Supply And Sanitation Department Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Water Supply And Sanitation Department - WSS Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date4 Jan 2023
Closing Date23 Jan 2023
Tender Amount₹ 37,06,917
Costs
EMD
₹ 74,200Document Cost
Refer DocumentsTender Fee
₹ 4,374
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_WSS_94584_1Bid Award Id
ViewTender No
133/WSSD/MALERKOTLA/EE/2022-23Tender Authority
Water Supply And Sanitation Department ViewPurchaser Address
-Website
http://https://dwss.punjab.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
For 50mm pipe line
154.29
-
-
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.
-
-
-
CPVC SDR 11 pipe & fittings 50mm o/d
298.44
-
-
Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.
-
-
-
50mm i/d Gun Metal peet valve heavy pattern.
3
-
-
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
-
-
-
Size 0.6 m. x 0.6 m. (Qty. same as above)
3
-
-
Providing & Fixiing C.I indicating plates of size 100mm x 100 mm for SV/FH including synthetic enammel paint & letters in white enamel paint, fixing in the ground with angle iron of size 25x25x5mm, 230mm height from ground including conrete block complete in all respect as directed by Engineer-in-charge
-
-
-
Qty. same as above
3
-
-
Providing, fixing and jointing Cast Iron surface box for Sluice valve, Air valve, Fire hydrant etc. including all carriages complete.
-
-
-
Weight @33Kg per Box 3 nos.
99
-
-
Estate Sewerage
-
-
-
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
-
-
-
110 mm o/d pipes
-
-
-
For Sewer Line GT to IC 4mtr each 110mm o/d
114
-
-
110 mm o/d pipes
-
-
-
For Sewer Line IC to IC and IC to MH 4mtr each
114
-
-
160 mm o/d pipes
-
-
-
For main sewer line as per detail attached
261.12
-
-
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
-
-
-
For depth exceeding 3.00 m but not exceeding 4.5 B.G.L
All kinds of soil except rocky
465.51
-
-
Providing for Laying Local Sand under bed of UPVC pipes complete.
-
-
-
For Sewer Line
143.35
-
-
Constructing brick masonry manhole in cement mortar 1:5 (1 cement :5 coarse sand) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @80.00 kg/per cum, foundation concrete 1:4:8 mix (1cement :4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement: 2coarse sand: 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard
-
-
-
Inside size 90x150 cm Av depth= 1.15 mtr 7 nos
-
-
-
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
-
-
-
For Depth not exceeding 3 m. BGL
All kinds of soil except rocky
35.82
-
-
Cement Concrete 1:4:8 with stone ballast of size .40 mm guage. using concrete mixing volumetric type
5.31
-
-
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
8.96
-
-
Cement Concrete 1:2:4 with stone ballast or shingle. using concrete mixing volumetric type
2.18
-
-
Floating coat of 1:5 mm thick neat cement laid in one operation to the topping.
9.45
-
-
12.5 mm thick cement plaster 1:3.
32.69
-
-
Cement rendering on plaster 1mm thick
32.69
-
-
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
3.39
-
-
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
2.71
-
-
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
28
-
-
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).
RCC Man hole cover with Frame
560mm i/d RCC man hole cover with frame as per ISI
-
-
-
Medium duty
7
-
-
Inside size 90x150 cm on 160mm dia pipe line average depth 3.35 mtr Av depth = 2.09 mtr 8 nos.
-
-
-
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
-
-
-
For Depth not exceeding 3 m. BGL
All kinds of soil except rocky
69.43
-
-
For depth exceeding 3.0 but not exceeding 4.50 B.G.L.
All kinds of soil except rocky
18.19
-
-
Cement Concrete 1:4:8 with stone ballast of size .40 mm guage. using concrete mixing volumetric type
6.06
-
-
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
18.71
-
-
Cement Concrete 1:2:4 with stone ballast or shingle. using concrete mixing volumetric type
2.49
-
-
Floating coat of 1:5 mm thick neat cement laid in one operation to the topping.
10.8
-
-
12.5 mm thick cement plaster 1:3.
68.28
-
-
Cement rendering on plaster 1mm thick
68.28
-
-
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
3.87
-
-
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
3.1
-
-
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
48
-
-
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).
RCC Man hole cover with Frame
560mm i/d RCC man hole cover with frame as per ISI
-
-
-
Medium duty
8
-
-
Extra for making connections of all sizes newly laid sewers within benching of fully charged sewers including pluging of sewer, dewatering & desilting of manholes etc.
-
-
-
with existing sewer of 300 mm id and below
1
-
-
Roof Top Rain water Harvesting
-
-
-
Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc.
R.C.C. Pipe NP -2
-
-
-
200mm i/d pipe (For Storm water line 200mm i/d pipe as per Detail attached)
255.98
-
-
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
-
-
-
110mm o/d PVC pipe of 4 Kgf. / sqcm (For connection of Road gully and water line @ 4mtr. Each per road gully)
228
-
-
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
-
-
-
For depth not exceeding 3 m. BGL
For all classes of soil except rocky
564.51
-
-
Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick Masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge
-
-
-
Haudi Inside size 90 x 90 cm and 90 cm deep
37
-
-
Construction of Haudi internal size 0.45mtr x 0.45mtr & 0.45mtr depth in Brick Masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x450 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge
-
-
-
No. of Haudi @ 4 mtr. C/c Distance of Rain Water pipe line
57
-
-
Construction of Rain water recharge well 3.00mtr dia with working depth 3.50mtr dia consisting of drilling bore 200mm dia 50mtr, supplying and lowering pvc perforated housing pipe 160 mm dia 6kgf/sqcm 50mtr sorrunded with PVC strainer, 160mm i/d 14mtr duly plugged from top with well cap, fixing MS clamp, Well size 3.00 mtr internal dia, 4.00 mtr deep constructed with BB in 1:5 cement sand mortar, plastered from inside, M.S. angle iron cover for protection of bore hole pit and all other relevent material required as per site complete in all respect as per drawing attached and entire satisfaction of the Engineer-in-charge. (Note :- Payment will be made as per CSR based rates plus/Minus Quoted rates).
(Recharging well Rs. 116729 + Bore Hole Rs. 91953 = 208682)
2
-
-
Fire Fighting Arrangements (Design and SOP drawing will be provided by the Contractor)
-
-
-
Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.
4.5 Kg. Capacity
6
-
-
Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.
6 Kg. Capacity
6
-
-
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS :
1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts.
100mm internal diameter
100
-
-
SITC of MS Pipe
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS :
1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.
-
-
-
100mm internal diameter
30
-
-
SITC of Butterfly valve
Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.
-
-
-
100mm i/d
2
-
-
Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.
-
-
-
100mm i/d check valve
2
-
-
Providing and fixing S.S Pressure Gauge complete as required complete in all respect.
-
-
-
Dial diameter 100mm calibration 0-16 Kg
2
-
-
Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank).
-
-
-
Two Way inlet connection
2
-
-
Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required.
4
-
-
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.
4
-
-
Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc.
-
-
-
600 mm wide x 600 mm high x 300 mm deep Size - (for RRL Reel)
2
-
-
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).
Class PN-1 as per ISI
-
-
-
100mm i/d Sluice Valves flanged
4
-
-
Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required
2
-
-
Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all restect
2
-
-
Supplying and Installation control valve C/W water motor gong complete with alarm Valve, constant trim, water motor bell, 2No. Pressure Gauge. All parts UL listed. Make Newage complete in all respect.
-
-
-
100 mm control valve
1
-
-
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Triple Layer Tanks
20000
-
-
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.
Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra.
Class PN-1.0 as per ISI with gun metal flap
-
-
-
100mm i/d Non-return valve
2
-
-
Providing and fixing in position automatic brass Ball Cock in tanks.
Brass Ball Cock with rod and Plastic Ball
-
-
-
25mm i/d
2
-
-
Construction of Foundation for PVC water storage tank including RCC slab
2
-
-
Fabrication, Supply, Installing, testing and commissioning of cubical type fully enclosed panel switch gear connection, interconnection with AC strip flexible copper conductor MCCB, fully automatic star delta starter, etc complete required cable voltmeter.
1
-
-
Supply & erection of elctrically pumping machinery set (pump and motor) Make Crompton greaves confirming to ISI:8034-2002 with latest amendments, with discharge of 450 LPM at head 35 mtr covered with rain shelter complete in all respect as per specifications.
2
-
-
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 4.0sq.mm (84/0.3mm), 3Core
30
-
-
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
30
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements