Water Supply And Sanitation Department Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Water Supply And Sanitation Department Tender

Eprocure
Opening Date28 Sep 2020
Closing Date10 Nov 2020
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 14,60,000
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 5,900

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Loading of Excavated Earth : ( By Mechanical Means)

-

-

-

... More
Rate for loading into wagons, trucks or boats within 15-30 metres lead. Sub Total :Loading of earth :From GL .Above 2.0 m.

1000.52

-

-

... More
PCC M-20 :

-

-

-

... More
Cement Concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type

33.4

-

-

... More
Extra for using needle vibrator where not included in rates

33.4

-

-

... More
M-30 :Raft Foundation Concrete : RCC :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in first storey in super structure

87.98

-

-

... More
Shuttering for RCC M-30 :For Raft foundation :

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or Battering.)

86.24

-

-

... More
Steel : (For Raft Foundation) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

52.79

-

-

... More
Up to Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in foundation and plinth.(first storey up to 4 m height)

75.69

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

3.58

-

-

... More
Centring and Shuttering for RCC M-30 :Concrete work In walls and columns :

-

-

-

... More
Centring and shuttering for faces of walls,partitions,retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc.

572.9

-

-

... More
Centring and shuttering for columns (square or rectangular or polygonal in olain)

102.5

-

-

... More
DPC for Panel Room :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg./Sqm. Laid hot and sanded.

2.41

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

88.87

-

-

... More
RCC M-30 :For Slab Beams :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

16.69

-

-

... More
Centring and shuttering for sides and soffits of beam, beams, launchings, girders, bressumers, lintels.

175.41

-

-

... More
RCC M-30 :For Slab :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

48.14

-

-

... More
Centring and Shuttering : For Slab :

-

-

-

... More
Centring and shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc.

297.06

-

-

... More
Steel : (For Slab and Ventilators ) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

38.51

-

-

... More
Supplying & Fixing of Rolling Shutters of approved make :

-

-

-

... More
Pump House

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of 80 mm.x 1.25 mm. M.S.Laths.interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides 27.5 cm.long wire spring grade No.2 and arrangement for inside and outside locking with push and pull operation complete including top cover 80 mm.thick ( payment is to be made for the exact size of opening ; where rolling shutter is to be fixed).

18

-

-

... More
Supplying & Fixing Steel Ventilators :Pump House :

-

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

234

-

-

... More
Supplying & Fixing Glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

9.6

-

-

... More
Wire gauge fixing to Reservoir Slab Ventilators and Pump House Ventilators :

-

-

-

... More
Providing & Fixing of 10 gauge welded mesh of 25 mm.*25 mm. size fixed on steel glazing with MS flat 20 mm.*6 mm.beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming coat.

8.4

-

-

... More
MS Stair Case Railing : Pump House :

-

-

-

... More
Providing and fixing stair case railing made out of M.S.square bars 20 mm.x 20 mm. as vertical part 0.70 m.high fixed with M.S. base plate of 40 mm.x 40 mm x.6 mm. and flat iron 40 mm.x 6 mm.as hand rail complete in all respect.

31.85

-

-

... More
Provision of Mild Steel Ladder in Pump House :

-

-

-

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors,staircase,iron railing including cost of bolts and nuts or screws or welding rod complete fixed in position.

3.6

-

-

... More
Galvanized Corrugated Iron Sheet :

-

-

-

... More
For Staircase Steps :

-

-

-

... More
Galvanized Corrugated Iron Sheet :Pitch : 75 mm. nominal and Depth of Corrugation : 18 mm. nominal

-

-

-

... More
Structural steel work in angles,tees and flats, riveted or welded including cutting, fixing all gusset plates,bolts,nuts,rivets,welding rod,etc. with hoisting and erecting in position.

-

-

-

... More
For roof trusses, well curbs, plates and trussed girders, etc.of any span for buildings and bridges up to 15 m.span.

0.5

-

-

... More
Air Vent Arrangement :

-

-

-

... More
Brick Work :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

2.76

-

-

... More
Manhole Cover :

-

-

-

... More
Supplying & fixing 560 mm.dia.SFRC manhole frame & cover as per IS:12592-2002 in existing manholes including grouting the frame in PCC M-15 complete in all respect as directed by the Engineer.

-

-

-

... More
Extra heavy duty

4

-

-

... More
Providing and fixing PVC Water Stops :

-

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete.

104

-

-

... More
Serrated with central bulb (225 mm. wide, 8-11 mm. thick).

-

-

-

... More
Brickwork in CM.1:5 in foundation and plinth : Panel Room ( L Shaped Brick Wall )

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

5.39

-

-

... More
Brickwork in CM.1:5 in first storey. : Panel Room Brick wall portion :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

40.98

-

-

... More
Earth Filling : (Panel Room)

-

-

-

... More
Earth filling under floors with surplus containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead up to 30 meters.

9.45

-

-

... More
Outside Cement Pointing: 1:2 deep variety :Pump House & panel Room

-

-

-

... More
Cement pointing 1 :2 deep variety

189.75

-

-

... More
Inside Plaster :20 mm.thick in CM 1:4 :Pump House Brick wall portion and Parapet wall :

-

-

-

... More
20 mm .thick cement plaster 1:4

196.8

-

-

... More
Parapet Wall :

-

-

-

... More
115 mm. thick brick wall laid in cement,lime, sand mortar 1:4 (One Cement,four sand) in superstructure up to 4 metres above plinth level.

12.41

-

-

... More
White washing :

-

-

-

... More
White washing (three coat)

91

-

-

... More
Preparation of concrete or plastered surfaces :

-

-

-

... More
Preparation of concrete or plastered surfaces for painting or oil-bound distemper including sand papering the surface finishing the surface to the required finish complete.

184.8

-

-

... More
Distempering (OBD) : Inside Painting :

-

-

-

... More
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

184.8

-

-

... More
Exterior paint :

-

-

-

... More
Finishing walls with exterior decorative cement based such as snowcem, robbiacem etc. On old work two coat to give an even shade.

202.8

-

-

... More
Cement Concrete 1:2:4 gola :

-

-

-

... More
Cement concrete 1:2:4 gola 10 cm.*10 cm. concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

82

-

-

... More
Top Khurra :

-

-

-

... More
Top khurra 0.6 m.*0.6 m. for rain water pipe in 25 mm.thick cement concrete 1:2:4 over 50 mm.thick cement concrete 1:8:16.

6

-

-

... More
Rain water pipes :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Rain water pipe (ring fitted type-A) as per IS: 13592 including jointing during masonry complete as per specifications and to the entire satisfaction of Engineer-in-charge. ( If fixed on wall face clamp to be paid separately as per respective items).

15

-

-

... More
Rain Water Pipe bend :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C.bend for Rain water pipe for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

8

-

-

... More
Rain Water Pipe coupling/socket :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Coupling/Socket for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

8

-

-

... More
40 mm.Thick Grey Polished Floor :

-

-

-

... More
40 mm. thick Grey Polished flooring cement concrete 1:2:4 topping finished with 3 mm.thick neat coat of cement rubbed and polished ( using mechanical mixer for mixing of material)

91

-

-

... More
Safety Foot Rest :

-

-

-

... More
Providing orange colour safety footrest of minimum 6 mm.thick plastic encapsulated as per IS : 10910 on 12 mm. dia. Steel bar conforming to IS : 1786 having minimum cross section as 23 mm.x25 mm. and over all minimum length 263 mm.and width as 165 mm.with minimum 112 mm.space between protrude legs having 2 mm.tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm.as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230 x150x75cm. Cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggregate) complete as per design.

14

-

-

... More
Soil investigation, Structural design and vetting of structural design from reputed engineering institute.

1

-

-

... More
Carriage of materials :

-

-

-

... More
Earth, Surkhi, Sand, Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

667.31

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

5.37

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

234.67

-

-

... More
11.0 km. to 20.00 km.

234.67

-

-

... More
21.00 to 40.00 km.

234.67

-

-

... More
41.00 to 60.00 km.

234.67

-

-

... More
61.00-150.00 km.

234.67

-

-

... More
151.00-225.00 km.

234.67

-

-

... More
Fine aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

130.65

-

-

... More
11.0 km. to 20.00 km.

130.65

-

-

... More
21.00 to 40.00 km.

130.65

-

-

... More
41.00 to 60.00 km.

130.65

-

-

... More
61.00-150.00 km.

130.65

-

-

... More
151.00-225.00 km.

130.65

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

234.67

-

-

... More
Coarse Sand :From Damtal Quarry

130.65

-

-

... More
Cement :

2152

-

-

... More
Bricks :

22.95

-

-

... More
Sub Head No.2 : Construction of UGSR Phase-V

-

-

-

... More
Earthwork in excavation in foundation :Mechanically

-

-

-

... More
Earthwork in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator/JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering, dressing and disposal of surplus soils as directed up to 15 metre complete in all respects.

1527.58

-

-

... More
Loading of Excavated Earth : ( By Mechanical Means)

-

-

-

... More
Rate for loading into wagons, trucks or boats within 15-30 metres lead. Sub Total :Loading of earth :From GL.Above 2.0 mts.

1527.58

-

-

... More
PCC M-20 :

-

-

-

... More
Cement Concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type

50.73

-

-

... More
Extra for using needle vibrator where not included in rates

50.73

-

-

... More
M-30 :Raft Foundation Concrete : RCC :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in foundation and plinth.

92.44

-

-

... More
Shuttering for RCC M-30 :For Raft foundation :

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or Battering.)

108.98

-

-

... More
Steel : (For Raft Foundation) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

55.46

-

-

... More
RCC Up to Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in foundation and plinth.

90.23

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

4.87

-

-

... More
Centring and Shuttering for RCC M-30 :Concrete work In walls and columns :

-

-

-

... More
Centring and shuttering for faces of walls,partitions,retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc.

722.82

-

-

... More
Centring and shuttering for columns (square or rectangular or polygonal in olain)

143.8

-

-

... More
DPC for Panel Room :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg./Sqm. Laid hot and sanded.

2.41

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

98.88

-

-

... More
RCC M-30 :For Slab Beams :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

16.98

-

-

... More
Centring and shuttering for sides and soffits of beam,beams, launchings,girders,bressumers,lintels.

196.51

-

-

... More
RCC M-30 :For Slab :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

85.06

-

-

... More
Centring and Shuttering : For Slab :

-

-

-

... More
Centring and shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc.

459.46

-

-

... More
Steel : (For Slab and Ventilators ) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

68.05

-

-

... More
Supplying & Fixing of Rolling Shutters of approved make :

-

-

-

... More
Pump House

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of 80 mm.x 1.25 mm. M.S.Laths.interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides 27.5 cm.long wire spring grade No.2 and arrangement for inside and outside locking with push and pull operation complete including top cover 80 mm.thick ( payment is to be made for the exact size of opening ; where rolling shutter is to be fixed).

6

-

-

... More
Supplying & Fixing Steel Ventilators :Pump House :

-

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

276

-

-

... More
Supplying & Fixing Glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

11.4

-

-

... More
Wire gauge fixing to Reservoir Slab Ventilators and Pump House Ventilators :

-

-

-

... More
Providing & Fixing of 10 gauge welded mesh of 25 mm.*25 mm. size fixed on steel glazing with MS flat 20 mm.*6 mm.beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming coat.

12.6

-

-

... More
MS Stair Case Railing : Pump House :

-

-

-

... More
Providing and fixing stair case railing made out of M.S.square bars 20 mm.x 20 mm. as vertical part 0.70 m.high fixed with M.S. base plate of 40 mm.x 40 mm x.6 mm. and flat iron 40 mm.x 6 mm.as hand rail complete in all respect.

33.18

-

-

... More
Provision of Mild Steel Ladder in Pump House :

-

-

-

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors,staircase,iron railing including cost of bolts and nuts or screws or welding rod complete fixed in position.

3.6

-

-

... More
Galvanized Corrugated Iron Sheet : For Staircase Steps :

-

-

-

... More
Galvanized Corrugated Iron Sheet :Pitch : 75 mm. nominal and Depth of Corrugation : 18 mm. nominal

-

-

-

... More
Structural steel work in angles,tees and flats, riveted or welded including cutting, fixing all gusset plates,bolts,nuts,rivets,welding rod,etc. with hoisting and erecting in position.

-

-

-

... More
For roof trusses, well curbs, plates and trussed girders, etc. of any span for buildings and bridges up to 15 m.span.

0.5

-

-

... More
Air Vent Arrangement :

-

-

-

... More
Brick Work :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

4.14

-

-

... More
Manhole Cover :

-

-

-

... More
Supplying & fixing 560 mm.dia.SFRC manhole frame & cover as per IS : 12592-2002 in existing manholes including grouting the frame in PCC M-15 complete in all respect as directed by the Engineer.

-

-

-

... More
Extra heavy duty

6

-

-

... More
Providing and fixing PVC Water Stops :

-

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete.

140

-

-

... More
Serrated with central bulb (225 mm. wide, 8-11 mm. thick).

-

-

-

... More
Brickwork in CM.1:5 in foundation and plinth :

-

-

-

... More
Panel Room ( L Shaped Brick Wall )

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

5.39

-

-

... More
Brickwork in CM.1:5 in first storey. : Panel Room Brick wall portion :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

49.5

-

-

... More
Earth Filling : (Panel Room)

-

-

-

... More
Earth filling under floors with surplus containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead up to 30 meters.

10.37

-

-

... More
Outside Cement Pointing: 1:2 deep variety :Pump House & panel Room

-

-

-

... More
Cement pointing 1 :2 deep variety

189.75

-

-

... More
Inside Plaster :20 mm.thick in CM 1:4 :Pump House Brick wall portion and Parapet wall :

-

-

-

... More
20 mm .thick cement plaster 1:4 in two coat work.

236.16

-

-

... More
Parapet Wall :

-

-

-

... More
115 mm. thick brick wall laid in cement mortar 1:4 with out reinforcement in foundation and plinth.

14.81

-

-

... More
White washing :

-

-

-

... More
White washing (three coat)

119

-

-

... More
Preparation of concrete or plastered surfaces :

-

-

-

... More
Preparation of concrete or plastered surfaces for painting or oil-bound distemper including sand papering the surface finishing the surface to the required finish complete.

236.16

-

-

... More
Distempering (OBD) : Inside Painting :

-

-

-

... More
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

236.16

-

-

... More
Exterior paint :

-

-

-

... More
Finishing walls with exterior decorative cement based such as snowcem, robbiacem etc. On old work two coat to give an even shade.

252.69

-

-

... More
Cement Concrete 1:2:4 gola :

-

-

-

... More
Cement concrete 1:2:4 gola 10 cm.*10 cm. concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

118

-

-

... More
Top Khurra :

-

-

-

... More
Top khurra 0.6 m.*0.6 m. for rain water pipe in 25 mm.thick cement concrete 1:2:4 over 50 mm.thick cement concrete 1:8:16.

6

-

-

... More
Rain water pipes :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Rain water pipe (ring fitted type-A) sa per IS : 13592 including jointing during masonry complete as per specifications and to the entire satisfaction of Engineer-in-charge.( If fixed on wall face clamp to be paid separately as per respective items).

22.5

-

-

... More
Rain Water Pipe bend :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C.bend for Rain water pipe for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

12

-

-

... More
Rain Water Pipe coupling/socket :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Coupling/Socket for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

6

-

-

... More
40 mm.Thick Grey Polished Floor :

-

-

-

... More
40 mm. thick Grey Polished flooring cement concrete 1:2:4 topping finished with 3 mm.thick neat coat of cement rubbed and polished ( using mechanical mixer for mixing of material)

119

-

-

... More
Safety Foot Rest :

-

-

-

... More
Providing orange colour safety footrest of minimum 6 mm.thick plastic encapsulated as per IS : 10910 on 12 mm. dia. Steel bar conforming to IS : 1786 having minimum cross section as 23 mm.x25 mm. and over all minimum length 263 mm.and width as 165 mm.with minimum 112 mm.space between protrude legs having 2 mm.tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm.as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230 x150x75cm. cement concrete block 1:2:4 ( 1 cement : 2 sand: 4 stone aggregate) complete as per design.

14

-

-

... More
Soil investigation, Structural design and vetting of structural design from reputed engineering institute.

1

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi, Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

1015.25

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

5.64

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

304.17

-

-

... More
11.0 km. to 20.00 km.

304.17

-

-

... More
21.00 to 40.00 km.

304.17

-

-

... More
41.00 to 60.00 km.

304.17

-

-

... More
61.00-150.00 km.

304.17

-

-

... More
151.00-225.00 km.

304.17

-

-

... More
Fine aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

167.51

-

-

... More
11.0 km. to 20.00 km.

167.51

-

-

... More
21.00 to 40.00 km.

167.51

-

-

... More
41.00 to 60.00 km.

167.51

-

-

... More
61.00-150.00 km.

167.51

-

-

... More
151.00-225.00 km.

167.51

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

304.17

-

-

... More
Coarse Sand :From Damtal Quarry

167.51

-

-

... More
Cement :

2771

-

-

... More
Bricks :

26.35

-

-

... More
Sub Head No.3 : Construction of UGSR Phase-I

-

-

-

... More
Earthwork in excavation in foundation :Mechanically

-

-

-

... More
Earthwork in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator/JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering, dressing and disposal of surplus soils as directed up to 15 metre complete in all respects.

673.22

-

-

... More
Loading of Excavated Earth : ( By Mechanical Means)

-

-

-

... More
Rate for loading into wagons, trucks or boats within 15-30 metres lead. Sub Total :Loading of earth :From GL.Above 2.0 mts.

673.22

-

-

... More
PCC M-20 :

-

-

-

... More
Cement Concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type

23.01

-

-

... More
Extra for using needle vibrator where not included in rates

23.01

-

-

... More
M-30 :Raft Foundation Concrete : RCC :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

57.04

-

-

... More
Shuttering for RCC M-30 :For Raft foundation :

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or Battering.)

64.04

-

-

... More
Steel :

-

-

-

... More
(For Raft Foundation) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

34.22

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

58.67

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

3.06

-

-

... More
Centring and Shuttering for RCC M-30 :Concrete work In walls and columns :

-

-

-

... More
Centring and shuttering for faces of walls,partitions,retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc.

461.3

-

-

... More
Centring and shuttering for columns (square or rectangular or polygonal in olain)

67.8

-

-

... More
DPC for Panel Room :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg./Sqm. Laid hot and sanded.

2.76

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

61.12

-

-

... More
RCC M-30 :For Slab Beams :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

7.79

-

-

... More
Centring and shuttering for sides and soffits of beam,beams, launchings,girders,bressumers,lintels.

96.63

-

-

... More
RCC M-30 :For Slab :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

35.3

-

-

... More
Centring and Shuttering : For Slab :

-

-

-

... More
Centring and shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc.

201.36

-

-

... More
Steel : (For Slab and Ventilators ) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

28.24

-

-

... More
Supplying & Fixing of Rolling Shutters of approved make :

-

-

-

... More
Pump House

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of 80 mm.x 1.25 mm. M.S.Laths.interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides 27.5 cm.long wire spring grade No.2 and arrangement for inside and outside locking with push and pull operation complete including top cover 80 mm.thick ( payment is to be made for the exact size of opening ; where rolling shutter is to be fixed).

6

-

-

... More
Supplying & Fixing Steel Ventilators :Pump House :

-

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

220

-

-

... More
Supplying & Fixing Glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

9

-

-

... More
Wire gauge fixing to Reservoir Slab Ventilators and Pump House Ventilators :

-

-

-

... More
Providing & Fixing of 10 gauge welded mesh of 25 mm.*25 mm. size fixed on steel glazing with MS flat 20 mm.*6 mm.beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming coat.

7.8

-

-

... More
MS Stair Case Railing : Pump House :

-

-

-

... More
Providing and fixing stair case railing made out of M.S.square bars 20 mm.x 20 mm. as vertical part 0.70 m.high fixed with M.S. base plate of 40 mm.x 40 mm x.6 mm. and flat iron 40 mm.x 6 mm.as hand rail complete in all respect.

23.48

-

-

... More
Provision of Mild Steel Ladder in Pump House :

-

-

-

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors,staircase,iron railing including cost of bolts and nuts or screws or welding rod complete fixed in position.

3.6

-

-

... More
Galvanized Corrugated Iron Sheet :

-

-

-

... More
For Staircase Steps :

-

-

-

... More
Galvanized Corrugated Iron Sheet :Pitch : 75 mm. nominal and Depth of Corrugation : 18 mm. nominal

-

-

-

... More
Structural steel work in angles,tees and flats, riveted or welded including cutting, fixing all gusset plates,bolts,nuts,rivets,welding rod,etc. with hoisting and erecting in position.

-

-

-

... More
For roof trusses, well curbs, plates and trussed girders, etc.of any span for buildings and bridges up to 15 m.span.

0.5

-

-

... More
Air Vent Arrangement :

-

-

-

... More
Brick Work :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

2.76

-

-

... More
Manhole Cover :

-

-

-

... More
Supplying & fixing 560 mm.dia.SFRC manhole frame & cover as per IS : 12592-2002 in existing manholes including grouting the frame in PCC M-15 complete in all respect as directed by the Engineer.

-

-

-

... More
Extra heavy duty

4

-

-

... More
Providing and fixing PVC Water Stops :

-

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete.

80

-

-

... More
Serrated with central bulb (225 mm. wide,8-11 mm. thick).

-

-

-

... More
Brickwork in CM.1:5 in foundation and plinth : Panel Room ( L Shaped Brick Wall )

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

5.39

-

-

... More
Brickwork in CM.1:5 in first storey. : Panel Room Brick wall portion :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

33.49

-

-

... More
Earth Filling : (Panel Room)

-

-

-

... More
Earth filling under floors with surplus containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead up to 30 meters.

10.37

-

-

... More
Outside Cement Pointing: 1:2 deep variety :Pump House & panel Room

-

-

-

... More
Cement pointing 1 :2 deep variety

155.94

-

-

... More
Inside Plaster :20 mm.thick in CM 1:4 :Pump House Brick wall portion and Parapet wall :

-

-

-

... More
20 mm .thick cement plaster 1:4 in two coat work.

167.28

-

-

... More
Parapet Wall :

-

-

-

... More
115 mm. thick brick wall laid in cement mortar 1:4 with out reinforcement in foundation and plinth.

14.81

-

-

... More
White washing :

-

-

-

... More
White washing (three coat)

70

-

-

... More
Preparation of concrete or plastered surfaces :

-

-

-

... More
Preparation of concrete or plastered surfaces for painting or oil-bound distemper including sand papering the surface finishing the surface to the required finish complete.

167.28

-

-

... More
Distempering (OBD) : Inside Painting :

-

-

-

... More
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

167.28

-

-

... More
Exterior paint :

-

-

-

... More
Finishing walls with exterior decorative cement based such as snowcem, robbiacem etc. On old work two coat to give an even shade.

155.94

-

-

... More
Cement Concrete 1:2:4 gola :

-

-

-

... More
Cement concrete 1:2:4 gola 10 cm.*10 cm. concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

62

-

-

... More
Top Khurra :

-

-

-

... More
Top khurra 0.6 m.*0.6 m. for rain water pipe in 25 mm.thick cement concrete 1:2:4 over 50 mm.thick cement concrete 1:8:16.

6

-

-

... More
Rain water pipes :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Rain water pipe (ring fitted type-A) as per IS : 13592 including jointing during masonry complete as per specifications and to the entire satisfaction of Engineer-in-charge.( If fixed on wall face clamp to be paid separately as per respective items).

22.5

-

-

... More
Rain Water Pipe bend :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C.bend for Rain water pipe for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

12

-

-

... More
Rain Water Pipe coupling/socket :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Coupling/Socket for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

6

-

-

... More
40 mm.Thick Grey Polished Floor :

-

-

-

... More
40 mm. thick Grey Polished flooring cement concrete 1:2:4 topping finished with 3 mm.thick neat coat of cement rubbed and polished ( using mechanical mixer for mixing of material)

70

-

-

... More
Safety Foot Rest :

-

-

-

... More
Providing orange colour safety footrest of minimum 6 mm.thick plastic encapsulated as per IS : 10910 on 12 mm. dia. Steel bar conforming to IS : 1786 having minimum cross section as 23 mm.x25 mm. and over all minimum length 263 mm.and width as 165 mm.with minimum 112 mm.space between protrude legs having 2 mm.tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm.as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230 x150x75cm. cement concrete block 1:2:4 ( 1 cement : 2 sand: 4 stone aggregate) complete as per design.

14

-

-

... More
Soil investigation, Structural design and vetting of structural design from reputed engineering institute.

1

-

-

... More
Carriage of materials :

-

-

-

... More
Earth, Surkhi, Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

449.52

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

3.98

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

158.72

-

-

... More
11.0 km. to 20.00 km.

158.72

-

-

... More
21.00 to 40.00 km.

158.72

-

-

... More
41.00 to 60.00 km.

158.72

-

-

... More
61.00-150.00 km.

158.72

-

-

... More
151.00-225.00 km.

158.72

-

-

... More
Fine aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

90.01

-

-

... More
11.0 km. to 20.00 km.

90.01

-

-

... More
21.00 to 40.00 km.

90.01

-

-

... More
41.00 to 60.00 km.

90.01

-

-

... More
61.00-150.00 km.

90.01

-

-

... More
151.00-225.00 km.

90.01

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

158.72

-

-

... More
Coarse Sand :From Damtal Quarry

90.01

-

-

... More
Cement :

1494

-

-

... More
Bricks :

18.67

-

-

... More
Sub Head No.4 : Construction of UGSR Phase-II

-

-

-

... More
Earthwork in excavation in foundation :Mechanically

-

-

-

... More
Earthwork in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator/JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering, dressing and disposal of surplus soils as directed up to 15 metre complete in all respects.

673.22

-

-

... More
Loading of Excavated Earth : ( By Mechanical Means)

-

-

-

... More
Rate for loading into wagons, trucks or boats within 15-30 metres lead. Sub Total :Loading of earth :From GL.Above 2.0 mts.

673.22

-

-

... More
PCC M-20 :

-

-

-

... More
Cement Concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type

23.01

-

-

... More
Extra for using needle vibrator where not included in rates

23.01

-

-

... More
M-30 :Raft Foundation Concrete : RCC :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

57.04

-

-

... More
Shuttering for RCC M-30 :For Raft foundation :

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or Battering.)

64.04

-

-

... More
Steel : (For Raft Foundation) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

34.22

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

58.67

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

3.06

-

-

... More
Centring and Shuttering for RCC M-30 :Concrete work In walls and columns :

-

-

-

... More
Centring and shuttering for faces of walls,partitions,retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc.

461.3

-

-

... More
Centring and shuttering for columns (square or rectangular or polygonal in olain)

67.8

-

-

... More
DPC for Panel Room :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg./Sqm. Laid hot and sanded.

2.76

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

61.12

-

-

... More
RCC M-30 :For Slab Beams :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

7.79

-

-

... More
Centring and shuttering for sides and soffits of beam,beams, launchings,girders,bressumers,lintels.

96.63

-

-

... More
RCC M-30 :For Slab :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

35.3

-

-

... More
Centring and Shuttering : For Slab :

-

-

-

... More
Centring and shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc.

201.36

-

-

... More
Steel : (For Slab and Ventilators ) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

28.24

-

-

... More
Supplying & Fixing of Rolling Shutters of approved make :

-

-

-

... More
Pump House

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of 80 mm.x 1.25 mm. M.S.Laths.interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides 27.5 cm.long wire spring grade No.2 and arrangement for inside and outside locking with push and pull operation complete including top cover 80 mm.thick ( payment is to be made for the exact size of opening ; where rolling shutter is to be fixed).

6

-

-

... More
Supplying & Fixing Steel Ventilators :Pump House :

-

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

220

-

-

... More
Supplying & Fixing Glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

9

-

-

... More
Wire gauge fixing to Reservoir Slab Ventilators and Pump House Ventilators :

-

-

-

... More
Providing & Fixing of 10 gauge welded mesh of 25 mm.*25 mm. size fixed on steel glazing with MS flat 20 mm.*6 mm.beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming coat.

7.8

-

-

... More
MS Stair Case Railing : Pump House :

-

-

-

... More
Providing and fixing stair case railing made out of M.S.square bars 20 mm.x 20 mm. as vertical part 0.70 m.high fixed with M.S. base plate of 40 mm.x 40 mm x.6 mm. and flat iron 40 mm.x 6 mm.as hand rail complete in all respect.

23.48

-

-

... More
Provision of Mild Steel Ladder in Pump House :

-

-

-

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors,staircase,iron railing including cost of bolts and nuts or screws or welding rod complete fixed in position.

3.6

-

-

... More
Galvanized Corrugated Iron Sheet :

-

-

-

... More
For Staircase Steps :

-

-

-

... More
Galvanized Corrugated Iron Sheet :Pitch : 75 mm. nominal and Depth of Corrugation : 18 mm. nominal

-

-

-

... More
Structural steel work in angles,tees and flats, riveted or welded including cutting, fixing all gusset plates,bolts,nuts,rivets,welding rod,etc. with hoisting and erecting in position.

-

-

-

... More
For roof trusses, well curbs, plates and trussed girders,etc.of any span for buildings and bridges up to 15 m.span.

0.5

-

-

... More
Air Vent Arrangement :

-

-

-

... More
Brick Work :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

2.76

-

-

... More
Manhole Cover :

-

-

-

... More
Supplying & fixing 560 mm.dia.SFRC manhole frame & cover as per IS : 12592-2002 in existing manholes including grouting the frame in PCC M-15 complete in all respect as directed by the Engineer.

-

-

-

... More
Extra heavy duty

4

-

-

... More
Providing and fixing PVC Water Stops :

-

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete.

80

-

-

... More
Serrated with central bulb (225 mm. wide,8-11 mm. thick).

-

-

-

... More
Brickwork in CM.1:5 in foundation and plinth :

-

-

-

... More
Panel Room ( L Shaped Brick Wall )

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

5.39

-

-

... More
Brickwork in CM.1:5 in first storey. : Panel Room Brick wall portion :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

33.49

-

-

... More
Earth Filling : (Panel Room)

-

-

-

... More
Earth filling under floors with surplus containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead up to 30 meters.

10.37

-

-

... More
Outside Cement Pointing: 1:2 deep variety :Pump House & panel Room

-

-

-

... More
Cement pointing 1 :2 deep variety

155.94

-

-

... More
Inside Plaster :20 mm.thick in CM 1:4 :Pump House Brick wall portion and Parapet wall :

-

-

-

... More
20 mm .thick cement plaster 1:4 in two coat work.

167.28

-

-

... More
Parapet Wall :

-

-

-

... More
115 mm. thick brick wall laid in cement mortar 1:4 without reinforcement in foundation and plinth.

14.81

-

-

... More
White washing :

-

-

-

... More
White washing (three coat)

70

-

-

... More
Preparation of concrete or plastered surfaces :

-

-

-

... More
Preparation of concrete or plastered surfaces for painting or oil-bound distemper including sand papering the surface finishing the surface to the required finish complete.

167.28

-

-

... More
Distempering (OBD) : Inside Painting :

-

-

-

... More
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

167.28

-

-

... More
Exterior paint :

-

-

-

... More
Finishing walls with exterior decorative cement based such as snowcem,robbiacem etc. On old work two coat to give an even shade.

155.94

-

-

... More
Cement Concrete 1:2:4 gola :

-

-

-

... More
Cement concrete 1:2:4 gola 10 cm.*10 cm. concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

62

-

-

... More
Top Khurra :

-

-

-

... More
Top khurra 0.6 m.*0.6 m. for rain water pipe in 25 mm.thick cement concrete 1:2:4 over 50 mm.thick cement concrete 1:8:16.

6

-

-

... More
Rain water pipes :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Rain water pipe (ring fitted type-A) as per IS : 13592 including jointing during masonry complete as per specifications and to the entire satisfaction of Engineer-in-charge.( If fixed on wall face clamp to be paid separately as per respective items).

22.5

-

-

... More
Rain Water Pipe bend :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C.bend for Rain water pipe for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

12

-

-

... More
Rain Water Pipe coupling/socket :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Coupling/Socket for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

6

-

-

... More
40 mm.Thick Grey Polished Floor :

-

-

-

... More
40 mm. thick Grey Polished flooring cement concrete 1:2:4 topping finished with 3 mm.thick neat coat of cement rubbed and polished ( using mechanical mixer for mixing of material)

70

-

-

... More
Safety Foot Rest :

-

-

-

... More
Providing orange colour safety footrest of minimum 6 mm.thick plastic encapsulated as per IS : 10910 on 12 mm. dia. Steel bar conforming to IS : 1786 having minimum cross section as 23 mm.x25 mm. and over all minimum length 263 mm.and width as 165 mm.with minimum 112 mm.space between protrude legs having 2 mm.tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm.as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230 x150x75cm. cement concrete block 1:2:4 ( 1 cement : 2 sand: 4 stone aggregate) complete as per design.

14

-

-

... More
Soil investigation, Structural design and vetting of structural design from reputed engineering institute.

1

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

449.52

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

3.98

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

158.72

-

-

... More
11.0 km. to 20.00 km.

158.72

-

-

... More
21.00 to 40.00 km.

158.72

-

-

... More
41.00 to 60.00 km.

158.72

-

-

... More
61.00-150.00 km.

158.72

-

-

... More
151.00-225.00 km.

158.72

-

-

... More
Fine aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

90.01

-

-

... More
11.0 km. to 20.00 km.

90.01

-

-

... More
21.00 to 40.00 km.

90.01

-

-

... More
41.00 to 60.00 km.

90.01

-

-

... More
61.00-150.00 km.

90.01

-

-

... More
151.00-225.00 km.

90.01

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

158.72

-

-

... More
Coarse Sand :From Damtal Quarry

90.01

-

-

... More
Cement :

1494

-

-

... More
Bricks :

18.67

-

-

... More
Sub Head No.5 : Construction of UGSR Sector 72

-

-

-

... More
Earthwork in excavation in foundation :Mechanically

-

-

-

... More
Earthwork in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator/JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering, dressing and disposal of surplus soils as directed up to 15 metre complete in all respects.

673.22

-

-

... More
Loading of Excavated Earth : ( By Mechanical Means)

-

-

-

... More
Rate for loading into wagons, trucks or boats within 15-30 metres lead. Sub Total :Loading of earth :From GL.Above 2.0 mts.

673.22

-

-

... More
PCC M-20 :

-

-

-

... More
Cement Concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type

23.01

-

-

... More
Extra for using needle vibrator where not included in rates

23.01

-

-

... More
M-30 :Raft Foundation Concrete : RCC :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

57.04

-

-

... More
Shuttering for RCC M-30 :For Raft foundation :

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or Battering.)

64.04

-

-

... More
Steel :

-

-

-

... More
(For Raft Foundation) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

34.22

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

58.67

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

3.06

-

-

... More
Centring and Shuttering for RCC M-30 :Concrete work In walls and columns :

-

-

-

... More
Centring and shuttering for faces of walls,partitions,retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc.

461.3

-

-

... More
Centring and shuttering for columns (square or rectangular or polygonal in olain)

67.8

-

-

... More
DPC for Panel Room :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg./Sqm. Laid hot and sanded.

2.76

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

61.12

-

-

... More
RCC M-30 :For Slab Beams :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

7.79

-

-

... More
Centring and shuttering for sides and soffits of beam,beams,launchings,girders,bressumers,lintels.

96.63

-

-

... More
RCC M-30 :For Slab :

-

-

-

... More
Above Plinth level :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

35.3

-

-

... More
Centring and Shuttering : For Slab :

-

-

-

... More
Centring and shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc.

201.36

-

-

... More
Steel : (For Slab and Ventilators ) :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

28.24

-

-

... More
Supplying & Fixing of Rolling Shutters of approved make :

-

-

-

... More
Pump House

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of 80 mm.x 1.25 mm. M.S.Laths.interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides 27.5 cm.long wire spring grade No.2 and arrangement for inside and outside locking with push and pull operation complete including top cover 80 mm.thick ( payment is to be made for the exact size of opening ; where rolling shutter is to be fixed).

6

-

-

... More
Supplying & Fixing Steel Ventilators :Pump House :

-

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

220

-

-

... More
Supplying & Fixing Glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

9

-

-

... More
Wire gauge fixing to Reservoir Slab Ventilators and Pump House Ventilators :

-

-

-

... More
Providing & Fixing of 10 gauge welded mesh of 25 mm.*25 mm. size fixed on steel glazing with MS flat 20 mm.*6 mm.beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming coat.

7.8

-

-

... More
MS Stair Case Railing : Pump House :

-

-

-

... More
Providing and fixing stair case railing made out of M.S.square bars 20 mm.x 20 mm. as vertical part 0.70 m.high fixed with M.S. base plate of 40 mm.x 40 mm x.6 mm. and flat iron 40 mm.x 6 mm.as hand rail complete in all respect.

23.48

-

-

... More
Provision of Mild Steel Ladder in Pump House :

-

-

-

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors,staircase,iron railing including cost of bolts and nuts or screws or welding rod complete fixed in position.

3.6

-

-

... More
Galvanized Corrugated Iron Sheet :For Staircase Steps :

-

-

-

... More
Galvanized Corrugated Iron Sheet :Pitch : 75 mm. nominal and Depth of Corrugation : 18 mm. nominal

-

-

-

... More
Structural steel work in angles,tees and flats, riveted or welded including cutting, fixing all gusset plates,bolts,nuts,rivets,welding rod,etc. with hoisting and erecting in position.

-

-

-

... More
For roof trusses, well curbs, plates and trussed girders,etc.of any span for buildings and bridges up to 15 m.span.

0.5

-

-

... More
Air Vent Arrangement :

-

-

-

... More
Brick Work :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

2.76

-

-

... More
Manhole Cover :

-

-

-

... More
Supplying & fixing 560 mm.dia.SFRC manhole frame & cover as per IS : 12592-2002 in existing manholes including grouting the frame in PCC M-15 complete in all respect as directed by the Engineer.

-

-

-

... More
Extra heavy duty

4

-

-

... More
Providing and fixing PVC Water Stops :

-

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete.

80

-

-

... More
Serrated with central bulb (225 mm. wide,8-11 mm. thick).

-

-

-

... More
Brickwork in CM.1:5 in foundation and plinth :Panel Room ( L Shaped Brick Wall )

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

5.39

-

-

... More
Brickwork in CM.1:5 in first storey. : Panel Room Brick wall portion :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

33.49

-

-

... More
Earth Filling : (Panel Room)

-

-

-

... More
Earth filling under floors with surplus containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead up to 30 meters.

10.37

-

-

... More
Outside Cement Pointing: 1:2 deep variety :Pump House & panel Room

-

-

-

... More
Cement pointing 1 :2 deep variety

155.94

-

-

... More
Inside Plaster :20 mm.thick in CM 1:4 :Pump House Brick wall portion and Parapet wall :

-

-

-

... More
20 mm .thick cement plaster 1:4 in two coat work.

167.28

-

-

... More
Parapet Wall :

-

-

-

... More
115 mm. thick brick wall laid in cement mortar 1:4 without reinforcement in foundation and plinth.

14.81

-

-

... More
White washing :

-

-

-

... More
White washing (three coat)

70

-

-

... More
Preparation of concrete or plastered surfaces :

-

-

-

... More
Preparation of concrete or plastered surfaces for painting or oil-bound distemper including sand papering the surface finishing the surface to the required finish complete.

167.28

-

-

... More
Distempering (OBD) : Inside Painting :

-

-

-

... More
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

167.28

-

-

... More
Exterior paint :

-

-

-

... More
Finishing walls with exterior decorative cement based such as snowcem,robbiacem etc. On old work two coat to give an even shade.

155.94

-

-

... More
Cement Concrete 1:2:4 gola :

-

-

-

... More
Cement concrete 1:2:4 gola 10 cm.*10 cm. concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

62

-

-

... More
Top Khurra :

-

-

-

... More
Top khurra 0.6 m.*0.6 m. for rain water pipe in 25 mm.thick cement concrete 1:2:4 over 50 mm.thick cement concrete 1:8:16.

6

-

-

... More
Rain water pipes :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Rain water pipe ( ring fitted type-A) as per IS : 13592 including jointing during masonry complete as per specifications and to the entire satisfaction of Engineer-in-charge.( If fixed on wall face clamp to be paid separately as per respective items).

22.5

-

-

... More
Rain Water Pipe bend :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C.bend for Rain water pipe for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

12

-

-

... More
Rain Water Pipe coupling/socket :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C. Coupling/Socket for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

6

-

-

... More
40 mm.Thick Grey Polished Floor :

-

-

-

... More
40 mm. thick Grey Polished flooring cement concrete 1:2:4 topping finished with 3 mm.thick neat coat of cement rubbed and polished ( using mechanical mixer for mixing of material)

70

-

-

... More
Safety Foot Rest :

-

-

-

... More
Providing orange colour safety footrest of minimum 6 mm.thick plastic encapsulated as per IS : 10910 on 12 mm. dia. Steel bar conforming to IS : 1786 having minimum cross section as 23 mm.x25 mm. and over all minimum length 263 mm.and width as 165 mm.with minimum 112 mm.space between protrude legs having 2 mm.tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm.as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230 x150x75cm. cement concrete block 1:2:4 ( 1 cement : 2 sand: 4 stone aggregate) complete as per design.

14

-

-

... More
Soil investigation, Structural design and vetting of structural design from reputed engineering institute.

1

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

449.52

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

3.98

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

158.72

-

-

... More
11.0 km. to 20.00 km.

158.72

-

-

... More
21.00 to 40.00 km.

158.72

-

-

... More
41.00 to 60.00 km.

158.72

-

-

... More
61.00-150.00 km.

158.72

-

-

... More
151.00-225.00 km.

158.72

-

-

... More
Fine aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

90.01

-

-

... More
11.0 km. to 20.00 km.

90.01

-

-

... More
21.00 to 40.00 km.

90.01

-

-

... More
41.00 to 60.00 km.

90.01

-

-

... More
61.00-150.00 km.

90.01

-

-

... More
151.00-225.00 km.

90.01

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

158.72

-

-

... More
Coarse Sand :From Damtal Quarry

90.01

-

-

... More
Cement :

1494

-

-

... More
Bricks :

18.67

-

-

... More
Sub Head No.6 : Construction of Toilet Block

-

-

-

... More
Earthwork in excavation of foundations :

-

-

-

... More
Earthwork in excavation of foundations and trenches in all kinds of soil where pick and jumper work is not involved and not exceeding 2 m depth including of dressing of bottom and sides and stacking the excavated soil clear from the edge of excavation. of In foundation :

-

-

-

... More
For ordinary gravel soil involving pick work:

28.84

-

-

... More
Cement concrete 1:4:8 with stone ballast of size 40 mm gauge by using mechanical mixer volumetric type

5.76

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

19.9

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg per sqm.laid hot and sanded.

14.46

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 meters above plinth level.

17.08

-

-

... More
115 mm.thick brick wall in cement sand mortar 1:4 without reinforcement in super structure.

31.28

-

-

... More
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixture as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

5.54

-

-

... More
Centring and Shuttering :

44.22

-

-

... More
for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc. :

-

-

-

... More
Centring and Shuttering :

4.8

-

-

... More
for sides and soffits of beam,beams,launchings,girders,bressumers,lintels.

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

4.4

-

-

... More
12.5 mm.thick cement plaster 1:4

81.5

-

-

... More
20 mm.thick cement plaster 1:4 in two coats work .

163.9

-

-

... More
White washing (Three coat)

245.4

-

-

... More
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster o Paris and chalk mitti,including finishing the surface to the required finish complete.

245.4

-

-

... More
Finishing walls with acrylic smooth exterior paint of required shade with two coats applied @1.67 litre/10sqm over and including base coat of water proofing cement paint applied @220/10 Sqm.

81.5

-

-

... More
Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

163.9

-

-

... More
Earth filling under floors with surplus soil containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead uptom30 metres.

9.36

-

-

... More
Anti-skid floor tiles 10 mm. thick in flooring, skirting and dado in 12.5 mm. thick cement plaster 1:3 in base and jointed with white cement slurry in joints including corners, angles and beading.

21

-

-

... More
Providing and fixing 1st quality ceramic glazed tiles confirming to IS:15622 thickness to be specified by the manufacturer of approved make in all colours shades

20.7

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

160

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

-

-

-

... More
Glass panes 4 mm.thick above 0.40 Sqm Area.

4

-

-

... More
Kiln seasoned Hollock wood doors shutter with 12 mm.thick phenol Bonded BWP ply ISI Marked anchor, Kit ply, Nova Teak, National or equivalent including Chowkats iron hold fasts, Corner straps,Hinges,Screws,Shocks,Cleats,Stops and Cords etc. Complete fixed in position.(Single Leaf)

-

-

-

... More
Phenol Bounded B.W.P.ply panel :

-

-

-

... More
40 mm.thick

13.9

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc.

-

-

-

... More
With special quality paint

55.4

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

-

-

-

... More
With special quality paint

55.4

-

-

... More
Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.

-

-

-

... More
With special quality paint

16.2

-

-

... More
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make ( to the approval of the Engineer-in-charge) consisting of 10 litres PVC flushing cistern,PVC short bend 32 mm. dia. including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.

4

-

-

... More
Providing and fixing in position Metropole flush valve 32 mm.size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect.

4

-

-

... More
Providing and fixing in position Metropole flush valve 32 mm.size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect.

-

-

-

... More
Size 610 mm x 450 mm x 200 mm

4

-

-

... More
Providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, Varity counter and similar location in marble/granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of out edges etc. complete.

4

-

-

... More
Providing and fixing in position vitreous Chinaware white urinal with built in water seal outlet to wall and water inlet from back of approved make ( to the approval of Engineer-in-charge) complete in all respect.

4

-

-

... More
Providing and fixing partition for urinals :

-

-

-

... More
Vitreous white Chinaware Partition :

-

-

-

... More
Small partitions size : 680 mm x 300 mm

4

-

-

... More
Providing and fixing in position paper holders of approved make ( to the approval of Engineer-in*charge) fixed in to wall with C.P. brass screws complete in all respect.

-

-

-

... More
C.P.brass toilet paper holder

4

-

-

... More
Providing and fixing in position towel rails/ring of approved make ( to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.

-

-

-

... More
C.P.brass towel Rails size : 15 mm.dia. 600 mm. long.

4

-

-

... More
C.P.brass towel ring.

4

-

-

... More
Providing, laying ,jointing ,fixing and testing ISI Marked G.I.Pipe (as per IS : 1239) B-Class Premium make such as (Jindal,Hisar) including cost of specials ( such as tees,bends,sockets,elbows et) painting with anti corrosive bitumenstic paint, testing,cutting,threading inside building complete.

-

-

-

... More
15 mm.i/d.

30

-

-

... More
20 mm.i/d.

30

-

-

... More
Providing, laying ,jointing ,fixing and testing ISI Marked G.I.Pipe (as per IS : 1239) B-Class Premium make such as (Jindal,Hisar) including cost of specials ( such as tees,bends,sockets,elbows et) painting with anti corrosive bitumenstic paint, testing,cutting,threading inside building complete.

-

-

-

... More
PTMT Tap/Bib cock

8

-

-

... More
Providing & Fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) complete in all respects.

-

-

-

... More
PVC tube connection of size 15 mm.*450 mm. with PTMT nut.

8

-

-

... More
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I. pipes line and making good the same to it's original condition.

-

-

-

... More
Size 150 mm x 150 mm.

2

-

-

... More
Size 225 mm x 225 mm.

2

-

-

... More
Providing and fixing in positionC.P.Acrylic shelf with C.P.bracket and guard rails of approved make ( to the approval of Engineer-in-charge) fixed in with rawl plugs and C.P. brass screws complete in all respect.

-

-

-

... More
C.P.Acrylic Shelf size : 560 mm x 130 mm.

4

-

-

... More
Providing and fixing in position C.P.brass soap dish of approved make ( to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P. brass screws complete in all respect.

4

-

-

... More
Providing and fixing in position 5 mm. thick bevelled edge mirror of superior glass (of approved make) complete with 4 mm. thick hard board backing fixed in with rawl plugs 50 mm.C.P. brass screws and washers complete in all respect.(as required by the Engineer-in-charge).

-

-

-

... More
Size : 1500 mm x 600 mm or any other size.

4

-

-

... More
Providing and fixing in position liquid soap container (of approved make) (to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
C.P.brass liquid soap container

4

-

-

... More
Providing and fixing Stop cock/Angle valve :

-

-

-

... More
Providing and fixing in position stop cock/Angle valve of approved make( to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
C.P.brass 15 mm.Concealed stop cock with flange.

4

-

-

... More
Providing fixing G.M.ferrule :

-

-

-

... More
Providing ISI Marked G.M.Ferrule as per IS :2692 drilling and tapping cast iron pipe lines of all diameters and screwing in Ferrule and connections complete in all respect.

-

-

-

... More
15 mm.i/d.Ferrule medium

2

-

-

... More
20 mm.i/d.Ferrule medium

2

-

-

... More
Providing fixing HDPE Water Storage Tank :

-

-

-

... More
Providing and placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make ( to the approval of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet outlet and over flow pipes but without fittings and base support for tank.

-

-

-

... More
Triple Layer Tanks

4000

-

-

... More
Providing fixing HDPE Water Tank Cover :

-

-

-

... More
Providing and fixing in position on terrace (at all floor levels) HDPE tank cover for water storage tanks of approved make ( to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
For 1000 ltr.capacity tank and above.

2

-

-

... More
Providing fixing G.I.Tank Nipple :

-

-

-

... More
Providing and fixing in position G.I.Tank Nipple of approved make ( to the approval of Engineer-in-charge)in PVC Water storage tanks complete in all respects. complete in all respect.

-

-

-

... More
G.I.tank nipple 20 mm. i/d.

2

-

-

... More
Providing fixing Automatic Brass Ball Cock in tanks :

-

-

-

... More
Providing and fixing in position automatic brass ball cock in tank :

-

-

-

... More
Brass Ball Cock with rod and Plastic ball :

-

-

-

... More
20 mm.i/d.

2

-

-

... More
Providing and fixing in position grating :

-

-

-

... More
Providing and fixing in position grating of approved make ( to the approval of Engineer-in-charge) size 150 mm. x 150 mm.for gully trap.

-

-

-

... More
H.C.I.grating including painting with black bitumenstic superior paint of approved manufacture three coats.

8

-

-

... More
Providing,lowering,cutting &jointing Salt Glazed Stone Ware pipes and specials :

-

-

-

... More
Providing,lowering,cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS :651-2007 class Sp-1 into trenches for all depths and laying out the same to correct alingnment,gradients,levels etc. Cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching,haunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun jute yarn as per IS :1887,finishing and troweling of each joint at an angle of 45 degree with the longitudinal axes of pipe,watering,keeping the joint covered and wetted till the same are cured, testing the sewerage line for leakage and making all leakages and defects good as laid in the correct specification.......

-

-

-

... More
150 mm.i/d pipes.

50

-

-

... More
Providing, Fixing RCC Road Gully Grating & Frame :

-

-

-

... More
Providing & Fixing RCC Road Gully grating & frame

-

-

-

... More
600 mm. x 300 mm.

2

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

8.66

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

20.34

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

9.62

-

-

... More
11.0 km. to 20.00 km.

9.62

-

-

... More
21.00 to 40.00 km.

9.62

-

-

... More
41.00 to 60.00 km.

9.62

-

-

... More
61.00-150.00 km.

9.62

-

-

... More
151.00-225.00 km.

9.62

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

9.62

-

-

... More
Coarse Sand :From Damtal Quarry

20.34

-

-

... More
Cement :

155.12

-

-

... More
Bricks :

19.49

-

-

... More
Add for Electrical Cost @ 1.55% of estimated Cost .

2

-

-

... More
Sub Head No.7 : Pumping main for Phase-5

-

-

-

... More
Earthwork in excavation : By Mechanically :

-

-

-

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead up to 15 meter complete in all respect.

-

-

-

... More
Earthwork up to 1.50 mt.Depth.

-

-

-

... More
All classes of soil except rocky

1031.27

-

-

... More
Providing and laying DI K-9 Pipes :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.

-

-

-

... More
DI pipe as per IS 8329 DI-K9

-

-

-

... More
300mm i/d pipelines laid complete.

1094

-

-

... More
Providing and laying DI K-12 Specials :

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.

-

-

-

... More
DI Specials : Up to 300 mm.i/d.

2061.21

-

-

... More
Sluice Valve :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
300 mm.i/d Sluice Valves flanged.

2

-

-

... More
Providing and laying Air Valves :

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS : 14845 including jointing all carriages complete.

-

-

-

... More
C.I.Double air valve ( Size 100 mm)

2

-

-

... More
Jointing of DI pipes : For Specials :

-

-

-

... More
Jointing of D.I.Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. Complete in all respect.

-

-

-

... More
100 mm.i/d.pipelines.

2

-

-

... More
300 mm. i/d. pipelines.

2

-

-

... More
Providing and fixing Rubber Gaskets : For Specials :

-

-

-

... More
Providing and fixing of Rubber gasket

-

-

-

... More
100 mm.i/d.

4

-

-

... More
300 mm. i/d.

4

-

-

... More
DI Double Flanged Pipes :

-

-

-

... More
Providing, Stringing out,Cutting,Jointing and Testing of ISI Marked DI Double Flanged Pipes with screwed flanged as per IS : 8329-2000, Class k-9 and laying the same in trenches to correct alignment and gradients ,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.

-

-

-

... More
300 mm i/d. pipe lines laid complete.

6.4

-

-

... More
Valve Chambers

-

-

-

... More
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size : 0.90 m x 0.9 m

2

-

-

... More
Sub Head No.8 : Pumping main for Sector 72 & 73

-

-

-

... More
Earthwork in excavation : By Mechanically :

-

-

-

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead up to 15 meter complete in all respect.

-

-

-

... More
Earthwork up to 1.50 mt.Depth.

-

-

-

... More
All classes of soil except rocky

359.86

-

-

... More
Providing and laying DI K-9 Pipes :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.

-

-

-

... More
DI pipe as per IS 8329 DI-K9

-

-

-

... More
150mm i/d pipelines laid complete.

545

-

-

... More
Providing and laying DI K-12 Specials :

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.

-

-

-

... More
DI Specials : Up to 300 mm.i/d.

458.08

-

-

... More
Sluice Valve :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
150 mm.i/d Sluice Valves flanged.

1

-

-

... More
Providing and laying Air Valves :

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS : 14845 including jointing all carriages complete.

-

-

-

... More
C.I.Double air valve ( Size 80 mm)

1

-

-

... More
Jointing of DI pipes : For Specials :

-

-

-

... More
Jointing of D.I.Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. Complete in all respect.

-

-

-

... More
150 mm.i/pipelines.

1

-

-

... More
300 mm. i/d. pipelines.

-

-

-

... More
Providing and fixing Rubber Gaskets : For Specials :

-

-

-

... More
Providing and fixing of Rubber gasket

-

-

-

... More
150 mm.i/d.

2

-

-

... More
300 mm. i/d.

-

-

-

... More
DI Double Flanged Pipes :

-

-

-

... More
Providing, Stringing out,Cutting,Jointing and Testing of ISI Marked DI Double Flanged Pipes with screwed flanged as per IS : 8329-2000, Class k-9 and laying the same in trenches to correct alignment and gradients ,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.

-

-

-

... More
150 mm i/d. pipe lines laid complete.

3.2

-

-

... More
Valve Chambers

-

-

-

... More
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size : 0.90 m x 0.9 m

1

-

-

... More
Sub Head No.9 : Pumping main for Phase XI

-

-

-

... More
Earthwork in excavation : By Mechanically :

-

-

-

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead up to 15 meter complete in all respect.

-

-

-

... More
Earthwork up to 1.50 mt.Depth.

-

-

-

... More
All classes of soil except rocky

2112.61

-

-

... More
Providing and laying DI K-9 Pipes :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.

-

-

-

... More
DI pipe as per IS 8329 DI-K9

-

-

-

... More
350mm i/d pipelines laid complete.

2010

-

-

... More
Providing and laying DI K-12 Specials :

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.

-

-

-

... More
DI Specials : Above 300 mm.i/d.

2865.1

-

-

... More
Sluice Valve :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
350 mm.i/d Sluice Valves flanged.

1

-

-

... More
Providing and laying Air Valves :

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS : 14845 including jointing all carriages complete.

-

-

-

... More
C.I.Double air valve ( Size 100 mm)

4

-

-

... More
Jointing of DI pipes : For Specials :

-

-

-

... More
Jointing of D.I.Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. Complete in all respect.

-

-

-

... More
100 mm.i/pipelines.

4

-

-

... More
350 mm. i/d. pipelines.

1

-

-

... More
Providing and fixing Rubber Gaskets : For Specials :

-

-

-

... More
Providing and fixing of Rubber gasket

-

-

-

... More
100 mm.i/d.

8

-

-

... More
350 mm. i/d.

2

-

-

... More
DI Double Flanged Pipes :

-

-

-

... More
Providing, Stringing out,Cutting,Jointing and Testing of ISI Marked DI Double Flanged Pipes with screwed flanged as per IS : 8329-2000, Class k-9 and laying the same in trenches to correct alignment and gradients ,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.

-

-

-

... More
350 mm i/d. pipe lines laid complete.

8

-

-

... More
Valve Chambers

-

-

-

... More
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size : 0.90 m x 0.9 m

5

-

-

... More
Sub Head No.10 : Pumping main for Sector 48-C

-

-

-

... More
Earthwork in excavation : By Mechanically :

-

-

-

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead up to 15 meter complete in all respect.

-

-

-

... More
Earthwork up to 1.50 mt.Depth.

-

-

-

... More
All classes of soil except rocky

746.14

-

-

... More
Providing and laying DI K-9 Pipes :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.

-

-

-

... More
DI pipe as per IS 8329 DI-K9

-

-

-

... More
150mm i/d pipelines laid complete.

1130

-

-

... More
Providing and laying DI K-12 Specials :

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.

-

-

-

... More
DI Specials : Up to 300 mm.i/d.

949.78

-

-

... More
Sluice Valve :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
150 mm.i/d Sluice Valves flanged.

2

-

-

... More
Providing and laying Air Valves :

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS : 14845 including jointing all carriages complete.

-

-

-

... More
C.I.Double air valve ( Size 100 mm)

1

-

-

... More
Jointing of DI pipes : For Specials :

-

-

-

... More
Jointing of D.I.Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. Complete in all respect.

-

-

-

... More
100 mm.i/d.pipelines.

1

-

-

... More
150 mm. i/d. pipelines.

2

-

-

... More
Providing and fixing Rubber Gaskets : For Specials :

-

-

-

... More
Providing and fixing of Rubber gasket

-

-

-

... More
100 mm.i/d.

2

-

-

... More
150 mm. i/d.

4

-

-

... More
DI Double Flanged Pipes :

-

-

-

... More
Providing, Stringing out,Cutting,Jointing and Testing of ISI Marked DI Double Flanged Pipes with screwed flanged as per IS : 8329-2000, Class k-9 and laying the same in trenches to correct alignment and gradients ,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.

-

-

-

... More
150 mm i/d. pipe lines laid complete.

4.8

-

-

... More
Valve Chambers

-

-

-

... More
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size : 0.90 m x 0.9 m

3

-

-

... More
Sub Head No.11 : Pumping main for Sector 56

-

-

-

... More
Earthwork in excavation : By Mechanically :

-

-

-

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead up to 15 meter complete in all respect.

-

-

-

... More
Earthwork up to 1.50 mt.Depth.

-

-

-

... More
All classes of soil except rocky

104.92

-

-

... More
Providing and laying DI K-9 Pipes :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.

-

-

-

... More
DI pipe as per IS 8329 DI-K9

-

-

-

... More
200mm i/d pipelines laid complete.

140

-

-

... More
Providing and laying DI K-12 Specials :

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.

-

-

-

... More
DI Specials : Up to 300 mm.i/d.

154

-

-

... More
Sluice Valve :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm.i/d Sluice Valves flanged.

3

-

-

... More
Providing and laying Air Valves :

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS : 14845 including jointing all carriages complete.

-

-

-

... More
C.I.Double air valve ( Size 100 mm)

1

-

-

... More
Jointing of DI pipes : For Specials :

-

-

-

... More
Jointing of D.I.Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. Complete in all respect.

-

-

-

... More
100 mm.i/d.pipelines.

1

-

-

... More
200 mm. i/d. pipelines.

3

-

-

... More
Providing and fixing Rubber Gaskets : For Specials :

-

-

-

... More
Providing and fixing of Rubber gasket

-

-

-

... More
100 mm.i/d.

2

-

-

... More
200 mm. i/d.

6

-

-

... More
DI Double Flanged Pipes :

-

-

-

... More
Providing, Stringing out,Cutting,Jointing and Testing of ISI Marked DI Double Flanged Pipes with screwed flanged as per IS : 8329-2000, Class k-9 and laying the same in trenches to correct alignment and gradients ,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.

-

-

-

... More
200 mm i/d. pipe lines laid complete.

6.4

-

-

... More
Valve Chambers

-

-

-

... More
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size : 0.90 m x 0.9 m

4

-

-

... More
Sub Head No.12 : Pumping main for Mattour Area

-

-

-

... More
Earthwork in excavation : By Mechanically :

-

-

-

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead up to 15 meter complete in all respect.

-

-

-

... More
Earthwork up to 1.50 mt.Depth.

-

-

-

... More
All classes of soil except rocky

348.48

-

-

... More
Providing and laying DI K-9 Pipes :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.

-

-

-

... More
DI pipe as per IS 8329 DI-K9

-

-

-

... More
200mm i/d pipelines laid complete.

465

-

-

... More
Providing and laying DI K-12 Specials :

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.

-

-

-

... More
DI Specials : Up to 300 mm.i/d.

511.5

-

-

... More
Sluice Valve :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm.i/d Sluice Valves flanged.

2

-

-

... More
Providing and laying Air Valves :

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS : 14845 including jointing all carriages complete.

-

-

-

... More
C.I.Double air valve ( Size 100 mm)

1

-

-

... More
Jointing of DI pipes : For Specials :

-

-

-

... More
Jointing of D.I.Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. Complete in all respect.

-

-

-

... More
100 mm.i/d.pipelines.

1

-

-

... More
200 mm. i/d. pipelines.

2

-

-

... More
Providing and fixing Rubber Gaskets : For Specials :

-

-

-

... More
Providing and fixing of Rubber gasket

-

-

-

... More
100 mm.i/d.

2

-

-

... More
200 mm. i/d.

4

-

-

... More
DI Double Flanged Pipes :

-

-

-

... More
Providing, Stringing out,Cutting,Jointing and Testing of ISI Marked DI Double Flanged Pipes with screwed flanged as per IS : 8329-2000, Class k-9 and laying the same in trenches to correct alignment and gradients ,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.

-

-

-

... More
200 mm i/d. pipe lines laid complete.

4.8

-

-

... More
Valve Chambers

-

-

-

... More
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size : 0.90 m x 0.9 m

3

-

-

... More
Sub Head No.13 : Pumping main for Shahimajra

-

-

-

... More
Earthwork in excavation : By Mechanically :

-

-

-

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead up to 15 meter complete in all respect.

-

-

-

... More
Earthwork up to 1.50 mt.Depth.

-

-

-

... More
All classes of soil except rocky

374.71

-

-

... More
Providing and laying DI K-9 Pipes :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.

-

-

-

... More
DI pipe as per IS 8329 DI-K9

-

-

-

... More
200mm i/d pipelines laid complete.

500

-

-

... More
Providing and laying DI K-12 Specials :

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.

-

-

-

... More
DI Specials : Up to 300 mm.i/d.

550

-

-

... More
Sluice Valve :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm.i/d Sluice Valves flanged.

2

-

-

... More
Providing and laying Air Valves :

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS : 14845 including jointing all carriages complete.

-

-

-

... More
C.I.Double air valve ( Size 100 mm)

1

-

-

... More
Jointing of DI pipes : For Specials :

-

-

-

... More
Jointing of D.I.Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. Complete in all respect.

-

-

-

... More
100 mm.i/d.pipelines.

1

-

-

... More
200 mm. i/d. pipelines.

2

-

-

... More
Providing and fixing Rubber Gaskets : For Specials :

-

-

-

... More
Providing and fixing of Rubber gasket

-

-

-

... More
100 mm.i/d.

2

-

-

... More
200 mm. i/d.

4

-

-

... More
DI Double Flanged Pipes :

-

-

-

... More
Providing, Stringing out,Cutting,Jointing and Testing of ISI Marked DI Double Flanged Pipes with screwed flanged as per IS : 8329-2000, Class k-9 and laying the same in trenches to correct alignment and gradients ,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.

-

-

-

... More
200 mm i/d. pipe lines laid complete.

4.8

-

-

... More
Valve Chambers

-

-

-

... More
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size : 0.90 m x 0.9 m

3

-

-

... More
Sub Head No.14 : Construction of Chlorinator Room

-

-

-

... More
Earthwork in excavation of foundations :

-

-

-

... More
Earthwork in excavation of foundations and trenches in all kinds of soil where pick and jumper work is not involved and not exceeding 2 m depth including of dressing of bottom and sides and stacking the excavated soil clear from the edge of excavation. of

-

-

-

... More
In foundation :

-

-

-

... More
For ordinary gravel soil involving pick work:

18.8

-

-

... More
Foundation concrete : PCC 1:4 :8

-

-

-

... More
Cement concrete 1:4:8 with stone ballast of size 40 mm gauge by using mechanical mixer volumetric type

4.58

-

-

... More
RCC M-30 : Foundation and Plinth :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixture as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in foundation and plinth.

0.79

-

-

... More
RCC M-30 : Superstructure :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixture as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

0.83

-

-

... More
Steel for Columns and Beams :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel bar) Bars Fe 500 grade as per IS : 1786-2008, for R.C.C. works, where not including in the complete rate of R.C.C. including bending and placing in position complete.

3.98

-

-

... More
Brick work in CM 1:5 : In Foundation :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

11

-

-

... More
Damp proof course :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg per sqm.laid hot and sanded.

7.38

-

-

... More
Brick work in CM 1:5 : In Superstructure :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

7.79

-

-

... More
RCC M-30 : Slab,Lintels,Slab Beams and Chajjas :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixture as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

2.68

-

-

... More
Centring and Shuttering : For Slabs and Chajjas :

-

-

-

... More
Centring and Shuttering :

15.4

-

-

... More
for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc. :

-

-

-

... More
Centring and Shuttering : For lintels :

-

-

-

... More
Centring and Shuttering : for sides and soffits of beam,beams,launchings,girders,bressumers,lintels.

0.54

-

-

... More
Centring and Shuttering : For Columns :

-

-

-

... More
Centring and Shuttering : For Columns : (Square or Rectangular or Polygonal in plan)

17.8

-

-

... More
Outside Plaster :12.5 mm.thick in CM 1:4

-

-

-

... More
12.5 mm.thick cement plaster 1:4

45.15

-

-

... More
Inside Plaster : 20 mm.thick in CM 1:2 :

-

-

-

... More
20 mm.thick cement plaster 1:2 in two coat work

30.24

-

-

... More
White washing :

-

-

-

... More
White washing (Three coat)

75.39

-

-

... More
Preparation of plastered surface :

-

-

-

... More
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster o Paris and chalk mitti,including finishing the surface to the required finish complete.

75.39

-

-

... More
Distempering :

-

-

-

... More
Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade.

45.15

-

-

... More
Oil Bound Distemper :

-

-

-

... More
Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

30.24

-

-

... More
Earth filling under floors :

-

-

-

... More
Earth filling under floors with surplus soil containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead up to 30 metres.

10.19

-

-

... More
Grey Polished Flooring :

-

-

-

... More
40 mm. thick Grey Polished flooring cement concrete 1:2:4 topping finished with 3 mm.thick neat coat of cement rubbed and polished ( using mechanical mixer for mixing of material)

25.15

-

-

... More
Supplying & Fixing of Rolling Shutters of approved make :

-

-

-

... More
Chlorinator Room :

-

-

-

... More
Supplying and fixing rolling shutters of approved make, made of 80 mm.x 1.25 mm. M.S.Laths.interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides 27.5 cm.long wire spring grade No.2 and arrangement for inside and outside locking with push and pull operation complete including top cover 80 mm.thick ( payment is to be made for the exact size of opening ; where rolling shutter is to be fixed).

-

-

-

... More
Door : 1.50 x2.0=3 Sqm.

3

-

-

... More
Steel Work in Trusses :

-

-

-

... More
Structural steel work in angles,tees and flats, riveted or welded including cutting, fixing all gusset plates,bolts,nuts,rivets,welding rod,etc. with hoisting and erecting in position.

-

-

-

... More
For roof trusses, well curbs, plates and trussed girders,etc.of any span for buildings and bridges up to 15 m. span.

4.6

-

-

... More
Primer Coat on Metallic Surface :

-

-

-

... More
Applying priming coat with metal primer on new steel or iron work including preparation of surface,

-

-

-

... More
With special quality paint.

15

-

-

... More
Painting on Metallic Surface :

-

-

-

... More
Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.

-

-

-

... More
With special quality paint.

15

-

-

... More
Corrugated GI Sheet Roofing :

-

-

-

... More
Corrugated GI Sheet roofing 0.80 mm. thick fixed with galvanised iron J or L hooks 10 mm. dia. GI Limpet and Bitumen washers complete excluding the cost of purlins, rafters and trusses.

41.58

-

-

... More
Ridges & Valleys :

-

-

-

... More
Ridges and valleys 45 cm.overall, in plain GI Sheet 0.80 mm. fixed with galvanised iron J and L hooks 10 mm.diameter,GI Limp[et and bitumen washers complete.

6.3

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

5.64

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

9.87

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

7.55

-

-

... More
11.0 km. to 20.00 km.

7.55

-

-

... More
21.00 to 40.00 km.

7.55

-

-

... More
41.00 to 60.00 km.

7.55

-

-

... More
61.00-150.00 km.

7.55

-

-

... More
151.00-225.00 km.

7.55

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

7.55

-

-

... More
Coarse Sand :From Damtal Quarry

9.87

-

-

... More
Cement :

89.51

-

-

... More
Bricks :

9.02

-

-

... More
Add for Electrical Cost

1

-

-

... More
Sub Head No.15 : Construction of SCADA Room

-

-

-

... More
Earthwork in excavation of foundations :

-

-

-

... More
Earthwork in excavation of foundations and trenches in all kinds of soil where pick and jumper work is not involved and not exceeding 2 m depth including of dressing of bottom and sides and stacking the excavated soil clear from the edge of excavation. of

-

-

-

... More
In foundation :

-

-

-

... More
For ordinary gravel soil involving pick work:

25.93

-

-

... More
Foundation concrete : PCC 1:4 :8

-

-

-

... More
Cement concrete 1:4:8 with stone ballast of size 40 mm gauge by using mechanical mixer volumetric type

4.76

-

-

... More
RCC M-20 Foundation Concrete : Columns and Plinth Beams :

-

-

-

... More
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixture as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in foundation and plinth.

3.51

-

-

... More
Shuttering :For Column Foundation and Plinth Beam :

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

15.81

-

-

... More
Steel :For Plinth Beam Concrete :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

2.1

-

-

... More
Brick work in CM 1:5 :In Foundation :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

12.46

-

-

... More
Damp proof course :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg per sqm.laid hot and sanded.

8.74

-

-

... More
Brick work in CM 1:5 :

-

-

-

... More
In Superstructure :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

11.06

-

-

... More
115 mm.thick Brick work :

-

-

-

... More
115 mm.thick brick wall in cement sand mortar 1:4 without reinforcement in super structure.

9

-

-

... More
RCC M-20 : Slab,Lintels,Slab Beams and Chajjas :

-

-

-

... More
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixture as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

10.79

-

-

... More
Centring and Shuttering :For Slabs and Chajjas :

-

-

-

... More
Centring and Shuttering :

61.05

-

-

... More
for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc. :

-

-

-

... More
Centring and Shuttering :For lintels :

-

-

-

... More
Centring and Shuttering :

17.55

-

-

... More
for sides and soffits of beam,beams,launchings,girders,bressumers,lintels.

-

-

-

... More
Centring and Shuttering :For Columns :

-

-

-

... More
Centring and Shuttering :

12.72

-

-

... More
for columns.(Square or Rectangular or Poly Gonal in plan)

-

-

-

... More
Steel :For Slab and Lintel Beams:

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

9.32

-

-

... More
Outside Plaster :12.5 mm.thick in CM 1:4

-

-

-

... More
12.5 mm.thick cement plaster 1:4

79.25

-

-

... More
Inside Plaster :20 mm.thick in CM 1:4

-

-

-

... More
20 mm.thick cement plaster 1:4 in two coat work .

129.12

-

-

... More
Painting :

-

-

-

... More
White washing :

-

-

-

... More
White washing (Three coat)

208.37

-

-

... More
Preparation of plastered surface :

-

-

-

... More
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster o Paris and chalk mitti,including finishing the surface to the required finish complete.

208.37

-

-

... More
Distempering :

-

-

-

... More
Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade.

79.25

-

-

... More
Oil Bound Distemper :

-

-

-

... More
Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

129.12

-

-

... More
Earth filling under floors :

-

-

-

... More
Earth filling under floors with surplus soil containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead uptom30 metres.

18.63

-

-

... More
Anti-Skid Tiles Flooring :

-

-

-

... More
Anti-skid floor tiles 10 mm. thick in flooring, skirting and dado in 12.5 mm. thick cement plaster 1:3 in base and jointed with white cement slurry in joints including corners, angles and beading.

2.88

-

-

... More
Vitrified Floor Tiles Flooring :

-

-

-

... More
Providing and laying vitrified floor tiles 600*600 mm.manufactured size using Premium Soluble Salt Technology, with water absorption less than 0.08% and conforming to IS :15622 of approved make in all colours and shades, laid on 20 mm. thick cement mortar 1:4 ( 1 cement : 4 fine sand) for new flooring laid with cement based high polymer modified quick set tile adhesive ( water based) of approved make IS :15477 marked using 5 kg.adhesive per sqm.of tile area in average 3 mm.thickness over existing base etc. Complete.(Design is homogenous throughout the tile body)

32.83

-

-

... More
White glazed tiles :in skirting and dado :

-

-

-

... More
Providing and fixing 1st quality ceramic glazed tiles confirming to IS:15622 thickness to be specified by the manufacturer of approved make in all colours shades

9.68

-

-

... More
Supplying & Fixing Steel Windows and Ventilators :

-

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

204

-

-

... More
Fixing of Glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

-

-

-

... More
Glass panes 4 mm. thick above 0-40 Sqm. area.

18.23

-

-

... More
Hollock Wood Doors :

-

-

-

... More
Kiln seasoned Hollock wood doors shutter with 12 mm.thick phenol Bonded BWP ply ISI Marked anchor,Kit ply,Nova Teak,National or equivalent including Chowkats iron hold fasts,Corner straps,Hinges,Screws,Shocks,Cleats,Stops and Cords etc. Complete fixed in position.(Single Leaf)

-

-

-

... More
Phenol Bounded B.W.P.ply panel :

-

-

-

... More
40 mm.thick

7.34

-

-

... More
Applying pink primer or aluminium priming coat on wood work :

-

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc.

-

-

-

... More
With special quality paint

29.34

-

-

... More
Painting Synthetic Enamel Paint on Wood work :

-

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

-

-

-

... More
With special quality paint

29.34

-

-

... More
Painting on Steel work :

-

-

-

... More
Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.

-

-

-

... More
With special quality paint

72.9

-

-

... More
Providing and fixing in position Chinaware European type :

-

-

-

... More
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make ( to the approval of the Engineer-in-charge) consisting of 10 litres PVC flushing cistern,PVC short bend 32 mm. dia. including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.

1

-

-

... More
Providing and fixing in position Metropole flush valve :

-

-

-

... More
Providing and fixing in position Metropole flush valve 32 mm.size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect.

1

-

-

... More
Providing and fixing in position vitreous Chinaware sinks :

-

-

-

... More
Providing and fixing in position vitreous Chinaware sinks of approved make ( to the approval of the Engineer-in-charge) consisting of 40 mm.i/d. C.P. brass waste, pair of brackets complete in all respects.

-

-

-

... More
Size 610 mm. x 450 mm x 200 mm.

1

-

-

... More
Providing Opening for Wash Basin :

-

-

-

... More
Providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, Varity counter and similar location in marble/granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of out edges etc. complete.

1

-

-

... More
Providing and fixing Paper holders :

-

-

-

... More
Providing and fixing in position paper holders of approved make ( to the approval of Engineer-in*charge) fixed in to wall with C.P. brass screws complete in all respect.

-

-

-

... More
C.P.brass toilet paper holder

1

-

-

... More
Providing and fixing Towel rails/Rings :

-

-

-

... More
Providing and fixing in position towel rails/ring of approved make ( to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.

-

-

-

... More
C.P.brass towel Rails size : 15 mm.dia. 600 mm. long.

1

-

-

... More
C.P.brass towel ring.

1

-

-

... More
Providing and laying G.I.Pipe lines :

-

-

-

... More
Providing, laying ,jointing ,fixing and testing ISI Marked G.I.Pipe (as per IS : 1239) B-Class Premium make such as (Jindal,Hisar) including cost of specials ( such as tees,bends,sockets,elbows et) painting with anti corrosive bitumenstic paint, testing,cutting,threading inside building complete.

-

-

-

... More
15 mm.i/d.

30

-

-

... More
20 mm.i/d.

20

-

-

... More
Providing and fixing 15 mm.i/d.Bib-cock : :

-

-

-

... More
Providing & Fixing in position 15 mm.i/d. Bib-cock of approved make (to the approval of Engineer-in-charge) complete in all respects.

-

-

-

... More
PTMT Tap/Bib cock

1

-

-

... More
Cutting chase in brick walls in cement or in floor :

-

-

-

... More
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I. pipes line and making good the same to it's original condition.

-

-

-

... More
Size 150 mm.*150 mm.

20

-

-

... More
Size 225 mm.*225 mm.

20

-

-

... More
Providing and fixing C.P.Acrylic shelf :

-

-

-

... More
Providing and fixing in positionC.P.Acrylic shelf with C.P.bracket and guard rails of approved make ( to the approval of Engineer-in-charge) fixed in with rawl plugs and C.P. brass screws complete in all respect.

-

-

-

... More
C.P.Acrylic Shelf size : 560 mm.*130 mm.

1

-

-

... More
Providing and fixing C.P.Brass soap dish :

-

-

-

... More
Providing and fixing in position C.P.brass soap dish of approved make ( to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P. brass screws complete in all respect.

1

-

-

... More
Providing and fixing in position Mirror of superior glass :

-

-

-

... More
Providing and fixing in position 5 mm. thick bevelled edge mirror of superior glass (of approved make) complete with 4 mm. thick hard board backing fixed in with rawl plugs 50 mm.C.P. brass screws and washers complete in all respect.(as required by the Engineer-in-charge).

-

-

-

... More
Size : 1500 mm.*600 mm. or any other size.

1

-

-

... More
Providing and fixing Liquid soap container :

-

-

-

... More
Providing and fixing in position liquid soap container (of approved make) (to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
C.P.brass liquid soap container

1

-

-

... More
Providing and fixing Stop cock/Angle valve :

-

-

-

... More
Providing and fixing in position stop cock/Angle valve of approved make( to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
C.P.brass 15 mm.Concealed stop cock with flange.

1

-

-

... More
Providing fixing G.M.ferrule :

-

-

-

... More
Providing ISI Marked G.M.Ferrule as per IS :2692 drilling and tapping cast iron pipe lines of all diameters and screwing in Ferrule and connections complete in all respect.

-

-

-

... More
15 mm.i/d.Ferrule medium

1

-

-

... More
20 mm.i/d.Ferrule medium

1

-

-

... More
Providing fixing HDPE Water Storage Tank :

-

-

-

... More
Providing and placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make ( to the approval of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet outlet and over flow pipes but without fittings and base support for tank.

-

-

-

... More
Triple Layer Tanks

1000

-

-

... More
Providing fixing HDPE Water Tank Cover :

-

-

-

... More
Providing and fixing in position on terrace (at all floor levels) HDPE tank cover for water storage tanks of approved make ( to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
For 1000 ltr.capacity tank and above.

1

-

-

... More
Providing fixing G.I.Tank Nipple :

-

-

-

... More
Providing and fixing in position G.I.Tank Nipple of approved make ( to the approval of Engineer-in-charge)in PVC Water storage tanks complete in all respects. complete in all respect.

-

-

-

... More
G.I.tank nipple 20 mm. i/d.

1

-

-

... More
Providing fixing Automatic Brass Ball Cock in tanks :

-

-

-

... More
Providing and fixing in position automatic brass ball cock in tank :

-

-

-

... More
Brass Ball Cock with rod and Plastic ball :

-

-

-

... More
20 mm.i/d.

1

-

-

... More
Providing and fixing in position grating :

-

-

-

... More
Providing and fixing in position grating of approved make ( to the approval of Engineer-in-charge) size 150 mm.*150 mm.for gully trap.

-

-

-

... More
H.C.I.grating including painting with black bitumenstic superior paint of approved manufacture three coats.

1

-

-

... More
Providing,lowering,cutting &jointing Salt Glazed Stone Ware pipes and specials :

-

-

-

... More
Providing,lowering,cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS :651-2007 class Sp-1 into trenches for all depths and laying out the same to correct alingnment,gradients,levels etc. Cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching,haunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun jute yarn as per IS :1887,finishing and troweling of each joint at an angle of 45 degree with the longitudinal axes of pipe,watering,keeping the joint covered and wetted till the same are cured, testing the sewerage line for leakage and making all leakages and defects good as laid in the correct specification.......

-

-

-

... More
150 mm.i/d pipes.

25

-

-

... More
Providing, Fixing RCC Road Gully Grating & Frame :

-

-

-

... More
Providing & Fixing RCC Road Gully grating & frame

-

-

-

... More
600 mm.*300 mm.

1

-

-

... More
Plaster of Paris Ceiling :

-

-

-

... More
Plaster of Paris ceiling 12.5 mm. thick consisting of 12.5 mm. thick panels of plaster of Paris reinforced with hessian cloth fixed to under side of cradling of specified design, including cost of fixing in position all materials.etc.(cost of cradling to be paid separately)

36.12

-

-

... More
GI Cradling :

-

-

-

... More
Providing and Fixing ceiling consisting of 600 mm.*600 mm.*12.5 mm. thick Gypsum Board GI Cradling hanged from the ceiling by means of GI hanger complete as per drawings, specifications and to the entire satisfaction of Engineer-in charge.

36.12

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

7.78

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

15.01

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

16.19

-

-

... More
11.0 km. to 20.00 km.

16.19

-

-

... More
21.00 to 40.00 km.

16.19

-

-

... More
41.00 to 60.00 km.

16.19

-

-

... More
61.00-150.00 km.

16.19

-

-

... More
151.00-225.00 km.

16.19

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

16.19

-

-

... More
Coarse Sand :From Damtal Quarry

15.01

-

-

... More
Cement :

148.99

-

-

... More
Bricks :

4.69

-

-

... More
Add for Septic tank and discharge pits ,Pipelines with required accessories etc.

1

-

-

... More
Add for Electrical cost of the building

1

-

-

... More
Add for LT panel incoming cable MCB RCCB etc.

1

-

-

... More
Add for DG set silent as per approved make.10KVA

1

-

-

... More
Add for AC 1.50 tonne as per approved make for summer.

1

-

-

... More
Sub Head No.16 : Construction of PLC Room (2 nos)

-

-

-

... More
Earthwork in excavation of foundations :

-

-

-

... More
Earthwork in excavation of foundations and trenches in all kinds of soil where pick and jumper work is not involved and not exceeding 2 m depth including of dressing of bottom and sides and stacking the excavated soil clear from the edge of excavation. of

25.02

-

-

... More
In foundation :

-

-

-

... More
Foundation concrete :PCC 1:4 :8

-

-

-

... More
Cement concrete 1:4:8 with stone ballast of size 40 mm gauge by using mechanical mixer volumetric type

8.72

-

-

... More
Brick work in CM 1:5 : In Foundation :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

16.29

-

-

... More
Damp proof course :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg per sqm.laid hot and sanded.

9.96

-

-

... More
Brick work in CM 1:5 : In Superstructure :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

16.44

-

-

... More
RCC M-20 :

-

-

-

... More
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixture as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in foundation and plinth.

10.23

-

-

... More
Steel for Columns and Beams :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel bar) Bars Fe 500 grade as per IS : 1786-2008, for R.C.C. works, where not including in the complete rate of R.C.C. including bending and placing in position complete.

8.02

-

-

... More
Centring and Shuttering : For Slabs and Chajjas :

-

-

-

... More
Centring and Shuttering :

53.1

-

-

... More
for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc. :

-

-

-

... More
Centring and Shuttering : For lintels :

-

-

-

... More
Centring and Shuttering :

16.28

-

-

... More
for sides and soffits of beam,beams,launchings,girders,bressumers,lintels.

-

-

-

... More
Outside Plaster : 12.5 mm.thick in CM 1:4

-

-

-

... More
12.5 mm.thick cement plaster 1:4

100.41

-

-

... More
Inside Plaster :20 mm.thick in CM 1:4

-

-

-

... More
20 mm.thick cement plaster 1:4 in two coat work .

115

-

-

... More
White washing :

-

-

-

... More
White washing (Three coat)

215.4

-

-

... More
Preparation of plastered surface :

-

-

-

... More
Prepartion of plastered surfaces for distempering including surface,applying filling with approved quality filler consisting of plaster o Paris and chalk mitti,including finishing the surface to the required finish complete.

215.4

-

-

... More
Distempering :

-

-

-

... More
Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade.

100.41

-

-

... More
Oil Bound Distemper :

-

-

-

... More
Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

115

-

-

... More
Earth filling under floors :

-

-

-

... More
Earth filling under floors with surplus soil containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead up to 30 metres.

12.56

-

-

... More
Vitrified Floor Tiles Flooring :

-

-

-

... More
Providing and laying vitrified floor tiles 600*600 mm.manufactured size using Premium Soluble Salt Technology, with water absorption less than 0.08% and conforming to IS :15622 of approved make in all colours and shades, laid on 20 mm. thick cement mortar 1:4 ( 1 cement : 4 fine sand) for new flooring laid with cement based high polymer modified quick set tile adhesive ( water based) of approved make IS :15477 marked using 5 kg.adhesive per sqm.of tile area in average 3 mm.thickness over existing base etc. Complete.(Design is homogenous throughout the tile body)

21.9

-

-

... More
Supplying & Fixing Steel Windows and Ventilators :

-

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

300

-

-

... More
Fixing of Glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

-

-

-

... More
Glass panes 4 mm. thick above 0-40 Sqm. area.

29.7

-

-

... More
Hollock Wood Doors :

-

-

-

... More
Kiln seasoned Hollock wood doors shutter with 12 mm.thick phenol Bonded BWP ply ISI Marked anchor, Kit ply,Nova Teak,National or equivalent including Chowkats iron hold fasts,Corner straps,Hinges,Screws,Shocks,Cleats,Stops and Cords etc. Complete fixed in position.(Single Leaf)

-

-

-

... More
Phenol Bounded B.W.P.ply panel :

-

-

-

... More
40 mm.thick

7.2

-

-

... More
Applying pink primer or aluminium priming coat on wood work :

-

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc.

-

-

-

... More
With special quality paint

28.8

-

-

... More
Painting Synthetic Enamel Paint on Wood work :

-

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

-

-

-

... More
With special quality paint

28.8

-

-

... More
Painting on Steel work :

-

-

-

... More
Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.

-

-

-

... More
With special quality paint

118.8

-

-

... More
Plaster of Paris Ceiling :

-

-

-

... More
Plaster of paris ceiling 12.5 mm. thick consisting of 12.5 mm. thick panels of plaster of paris reinforced with hessian cloth fixed to under side of cradling of specified design, including cost of fixing in position all materials.etc.(cost of cradling to be paid separately)

21.9

-

-

... More
GI Cradling :

-

-

-

... More
Providing and Fixing ceiling consisting of 600 mm.*600 mm.*12.5 mm. thick Gypsum Board GI Cradling hanged from the ceiling by means of GI hanger complete as per drawings, specifications and to the entire satisfaction of Engineer-in charge.

21.9

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Earth :

-

-

-

... More
6.0 km. to 10.0 km.

7.5

-

-

... More
Sand (fine) :

-

-

-

... More
6.0 km. to 10.0 km.

20.7

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

16.12

-

-

... More
11.0 km. to 20.00 km.

16.12

-

-

... More
21.00 to 40.00 km.

16.12

-

-

... More
41.00 to 60.00 km.

16.12

-

-

... More
61.00-150.00 km.

16.12

-

-

... More
151.00-225.00 km.

16.12

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

16.12

-

-

... More
Coarse Sand :From Damtal Quarry

20.7

-

-

... More
Cement :

180.82

-

-

... More
Bricks :

15.71

-

-

... More
Add for Electrical cost of the building

2

-

-

... More
Add for AC arrangement in PLC Room

2

-

-

... More
Sub Head No.17 : Construction of Circular Backwash Tank

-

-

-

... More
Earthwork excavation :

-

-

-

... More
Excavation in Soil (any type) using Hydraulic Excavator CK 90.Excavation with hydraulic excavator of 0.9 cum.bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections. All lifts and lead up to 60 m.

1418.54

-

-

... More
Rate for loading :

-

-

-

... More
Earth :

1418.54

-

-

... More
PCC 1:2:4

-

-

-

... More
Cement Comcrete1:2:4 with stone ballast or shingle using concrete mixer volumetric type

31.68

-

-

... More
Extra for using needle vibrator where not included in the rate

31.68

-

-

... More
Raft foundation :

-

-

-

... More
Reinforced cement concrete M-30,mechnacially batch mixed using batch type concrete mixer as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in super structure.

88.7

-

-

... More
Shuttering :

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam.(vertical or battering.)

35.32

-

-

... More
Wall concrete :

-

-

-

... More
Reinforced cement concrete M-30,mechnacially batch mixed using batch type concrete mixer as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, entering and shuttering in superstructure.

98.08

-

-

... More
Centring and Shuttering for Wall concrete :

-

-

-

... More
Centring and shuttering for well kerbs complete in all respects.

-

-

-

... More
For Circular wells

659.36

-

-

... More
Steel :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

151.3

-

-

... More
PVC encapsulated steps :

-

-

-

... More
Providing orange colour safety footrest of minimum 6 mm.thick plastic encapsulated as per IS : 10910 on 12 mm. dia. Steel bar conforming to IS : 1786 having minimum cross section as 23 mm.x25 mm. and over all minimum length 263 mm.and width as 165 mm.with minimum 112 mm.space between protrude legs having 2 mm.tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm.as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230 x150x75cm. cement concrete block 1:2:4 ( 1 cement : 2 sand: 4 stone aggregate) complete as per design.

32

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kanker and Building Rubbish.

-

-

-

... More
Coarse aggregates :

-

-

-

... More
6.0 km. to 10.0 km.

279.62

-

-

... More
11.0 km. to 20.00 km.

279.62

-

-

... More
21.00 to 40.00 km.

279.62

-

-

... More
41.00 to 60.00 km.

279.62

-

-

... More
61.00-150.00 km.

279.62

-

-

... More
151.00-225.00 km.

279.62

-

-

... More
Difference in Rates of Materials :

-

-

-

... More
Coarse aggregates : (12mm./13.2 mm.Crushed Bajri) From Damtal Quarry

185.7

-

-

... More
Coarse Sand :From Damtal Quarry

93.94

-

-

... More
Cement :

1606.76

-

-

... More
Sub Head No.18 : Dismantling of Road work Phase-V

-

-

-

... More
Dismantling of Flexible Pavements (Bituminous Courses) (By Mechanical Means)

-

-

-

... More
Dismantling of bituminuos courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

59.08

-

-

... More
Dismantling of Flexible Pavements (Granular Courses) (By Manual Means)

-

-

-

... More
Dismantling of Granular courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

118

-

-

... More
Sub Head No.19 : Road Restoration for Phase-V

-

-

-

... More
Compacting original ground below embankment :

-

-

-

... More
Loosening, levelling and compacting original ground below embankment to facilitate placement of first layer of embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per technical clause305 of MORT & H specifications.

147.69

-

-

... More
WBM Grade-II :

-

-

-

... More
Water Bound Macadam Grading II (Without Screening for low volume Roads/ undersigned roads).

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

29.54

-

-

... More
At Labour Rate : 60%

44.31

-

-

... More
WBM Grade-III :

-

-

-

... More
Water Bound Macadam Grading III (Without Screening for low volume Roads/ undersigned roads).Providing, laying, spreading and compacting stone aggregates of grading III to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

29.54

-

-

... More
At Labour Rate : 60%

44.31

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For WBM-II & III)

-

-

-

... More
6-10 km

59.08

-

-

... More
11-20 km

59.08

-

-

... More
21-40 km.

59.08

-

-

... More
41-60 km.

59.08

-

-

... More
61-150 km.

59.08

-

-

... More
151-220 km.

59.08

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(80 mm)

2.95

-

-

... More
For stone metal(63-45 mm)

39.88

-

-

... More
For stone metal(53-22.4 mm)

16.25

-

-

... More
Prime coat @ 0.85 kg per Sqm.

-

-

-

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 kg/Sqm complete as per technical clause 502 of MORT&H specifications.

984.6

-

-

... More
Tack coat @ 0.40 Kg per Sqm.

-

-

-

... More
Providing and applying Tack coat

984.6

-

-

... More
with penetration grade bitumen VG -10 using bitumen pressure distributor at the rate of 0.40 kg/Sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause

-

-

-

... More
503 of MORT&H specifications.

-

-

-

... More
Surface dressing :

-

-

-

... More
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1 kg per Sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 510 of MORTH & H specifications.

984.6

-

-

... More
Open graded pre mix surface :

-

-

-

... More
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batch type hot mix plant with bituminous binder VG-30 @ 1.46 kg per Sqm, and laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 511 of MORT&H specifications.

984.6

-

-

... More
Seal coat type B :

-

-

-

... More
Providing and laying of premix sand seal coat premixed in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68 kg/Sqm laid to the specified levels ,grade and cross fall complete as per technical clause 513 of MORT& H specifications.

984.6

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface)

-

-

-

... More
6-10 km

41.35

-

-

... More
11-20 km

41.35

-

-

... More
21-40 km.

41.35

-

-

... More
41-60 km.

41.35

-

-

... More
61-150 km.

41.35

-

-

... More
151-225 km.

41.35

-

-

... More
Carriage of Fine sand : (For seal coat type-B)

-

-

-

... More
6 to 10 km.

0.59

-

-

... More
11 to 20 km.

0.59

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(13.2 mm)

32.49

-

-

... More
For stone metal(11.2 mm)

8.86

-

-

... More
Carriage of materials :

-

-

-

... More
Tar, Bitumen and other Road Binders :

-

-

-

... More
Carriage of Bitumen : Round the Trip lead is considered from Panipat Refinery.

-

-

-

... More
6 to 10 km.

4.32

-

-

... More
11 to 20 km.

4.32

-

-

... More
21 to 40 km.

4.32

-

-

... More
41 to 60 km.

4.32

-

-

... More
61 to 150 km.

4.32

-

-

... More
151 to 750 km. (350 km + 350 km)

4.32

-

-

... More
Less for Diff.Rate for Bitumen :

-

-

-

... More
Bitumen VG-10 :

2.22

-

-

... More
Bitumen VG-30 :

2.11

-

-

... More
Sub Head No.20 : Dismantling of Road work Sector 72 and 73

-

-

-

... More
Dismantling of Flexible Pavements (Bituminous Courses) (By Mechanical Means)

-

-

-

... More
Dismantling of bituminous courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

29.43

-

-

... More
Dismantling of Flexible Pavements (Granular Courses) (By Manual Means)

-

-

-

... More
Dismantling of Granular courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

59

-

-

... More
Sub Head No.21 : Road Restoration for Sector 72 and 73

-

-

-

... More
Compacting original ground below embankment :

-

-

-

... More
Loosening, levelling and compacting original ground below embankment to facilitate placement of first layer of embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per technical clause305 of MORT & H specifications.

73.58

-

-

... More
WBM Grade-II :

-

-

-

... More
Water Bound Macadam Grading II (Without Screening for low volume Roads/ undersigned roads).

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

14.72

-

-

... More
At Labour Rate : 60%

22.07

-

-

... More
WBM Grade-III :

-

-

-

... More
Water Bound Macadam Grading III (Without Screening for low volume Roads/ undersigned roads).Providing, laying, spreading and compacting stone aggregates of grading III to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

14.72

-

-

... More
At Labour Rate : 60%

22.07

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For WBM-II & III)

-

-

-

... More
6-10 km

29.43

-

-

... More
11-20 km

29.43

-

-

... More
21-40 km.

29.43

-

-

... More
41-60 km.

29.43

-

-

... More
61-150 km.

29.43

-

-

... More
151-220 km.

29.43

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(80 mm)

1.47

-

-

... More
For stone metal(63-45 mm)

19.87

-

-

... More
For stone metal(53-22.4 mm)

8.09

-

-

... More
Prime coat @ 0.85 kg per Sqm.

-

-

-

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 kg/Sqm complete as per technical clause 502 of MORT&H specifications.

490.5

-

-

... More
Tack coat @ 0.40 Kg per Sqm.

-

-

-

... More
Providing and applying Tack coat

490.5

-

-

... More
with penetration grade bitumen VG -10 using bitumen pressure distributor at the rate of 0.40 kg/Sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause

-

-

-

... More
503 of MORT&H specifications.

-

-

-

... More
Surface dressing :

-

-

-

... More
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1 kg per Sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 510 of MORTH & H specifications.

490.5

-

-

... More
Open graded pre mix surface :

-

-

-

... More
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batch type hot mix plant with bituminous binder VG-30 @ 1.46 kg per Sqm, and laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 511 of MORT&H specifications.

490.5

-

-

... More
Seal coat type B :

-

-

-

... More
Providing and laying of premix sand seal coat premixed in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68 kg/Sqm laid to the specified levels ,grade and cross fall complete as per technical clause 513 of MORT& H specifications.

490.5

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface)

-

-

-

... More
6-10 km

20.6

-

-

... More
11-20 km

20.6

-

-

... More
21-40 km.

20.6

-

-

... More
41-60 km.

20.6

-

-

... More
61-150 km.

20.6

-

-

... More
151-225 km.

20.6

-

-

... More
Carriage of Fine sand : (For seal coat type-B)

-

-

-

... More
6 to 10 km.

0.29

-

-

... More
11 to 20 km.

0.29

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(13.2 mm)

16.19

-

-

... More
For stone metal(11.2 mm)

4.41

-

-

... More
Carriage of materials :

-

-

-

... More
Tar, Bitumen and other Road Binders :

-

-

-

... More
Carriage of Bitumen : Round the Trip lead is considered from Panipat Refinery.

-

-

-

... More
6 to 10 km.

2.15

-

-

... More
11 to 20 km.

2.15

-

-

... More
21 to 40 km.

2.15

-

-

... More
41 to 60 km.

2.15

-

-

... More
61 to 150 km.

2.15

-

-

... More
151 to 750 km. (350 km + 350 km)

2.15

-

-

... More
Less for Diff.Rate for Bitumen :

-

-

-

... More
Bitumen VG-10 :

1.1

-

-

... More
Bitumen VG-30 :

1.05

-

-

... More
Sub Head No.22 : Dismantling of Road work Phase 48-C

-

-

-

... More
Dismantling of Flexible Pavements (Bituminous Courses) (By Mechanical Means)

-

-

-

... More
Dismantling of bituminous courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

61.02

-

-

... More
Dismantling of Flexible Pavements (Granular Courses) (By Manual Means)

-

-

-

... More
Dismantling of Granular courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

122

-

-

... More
Sub Head No.23 Road Restoration for Phase 48-C

-

-

-

... More
Compacting original ground below embankment :

-

-

-

... More
Loosening, levelling and compacting original ground below embankment to facilitate placement of first layer of embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per technical clause305 of MORT & H specifications.

152.55

-

-

... More
WBM Grade-II :

-

-

-

... More
Water Bound Macadam Grading II (Without Screening for low volume Roads/ undersigned roads).

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

30.51

-

-

... More
At Labour Rate : 60%

45.77

-

-

... More
WBM Grade-III :

-

-

-

... More
Water Bound Macadam Grading III (Without Screening for low volume Roads/ undersigned roads).Providing, laying, spreading and compacting stone aggregates of grading III to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

30.51

-

-

... More
At Labour Rate : 60%

45.77

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For WBM-II & III)

-

-

-

... More
6-10 km

61.02

-

-

... More
11-20 km

61.02

-

-

... More
21-40 km.

61.02

-

-

... More
41-60 km.

61.02

-

-

... More
61-150 km.

61.02

-

-

... More
151-220 km.

61.02

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(80 mm)

3.05

-

-

... More
For stone metal(63-45 mm)

41.19

-

-

... More
For stone metal(53-22.4 mm)

16.78

-

-

... More
Prime coat @ 0.85 kg per Sqm.

-

-

-

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 kg/Sqm complete as per technical clause 502 of MORT&H specifications.

1017

-

-

... More
Tack coat @ 0.40 Kg per Sqm.

-

-

-

... More
Providing and applying Tack coat

1017

-

-

... More
with penetration grade bitumen VG -10 using bitumen pressure distributor at the rate of 0.40 kg/Sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause

-

-

-

... More
503 of MORT&H specifications.

-

-

-

... More
Surface dressing :

-

-

-

... More
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1 kg per Sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 510 of MORTH & H specifications.

1017

-

-

... More
Open graded pre mix surface :

-

-

-

... More
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batch type hot mix plant with bituminous binder VG-30 @ 1.46 kg per Sqm, and laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 511 of MORT&H specifications.

1017

-

-

... More
Seal coat type B :

-

-

-

... More
Providing and laying of premix sand seal coat premixed in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68 kg/Sqm laid to the specified levels ,grade and cross fall complete as per technical clause 513 of MORT& H specifications.

1017

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface)

-

-

-

... More
6-10 km

42.71

-

-

... More
11-20 km

42.71

-

-

... More
21-40 km.

42.71

-

-

... More
41-60 km.

42.71

-

-

... More
61-150 km.

42.71

-

-

... More
151-225 km.

42.71

-

-

... More
Carriage of Fine sand : (For seal coat type-B)

-

-

-

... More
6 to 10 km.

0.61

-

-

... More
11 to 20 km.

0.61

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(13.2 mm)

33.56

-

-

... More
For stone metal(11.2 mm)

9.15

-

-

... More
Carriage of materials :

-

-

-

... More
Tar, Bitumen and other Road Binders :

-

-

-

... More
Carriage of Bitumen : Round the Trip lead is considered from Panipat Refinery.

-

-

-

... More
6 to 10 km.

4.46

-

-

... More
11 to 20 km.

4.46

-

-

... More
21 to 40 km.

4.46

-

-

... More
41 to 60 km.

4.46

-

-

... More
61 to 150 km.

4.46

-

-

... More
151 to 750 km. (350 km + 350 km)

4.46

-

-

... More
Less for Diff.Rate for Bitumen :

-

-

-

... More
Bitumen VG-10 :

2.29

-

-

... More
Bitumen VG-30 :

2.18

-

-

... More
Sub Head No.24 : Dismantling of Road work Phase 11

-

-

-

... More
Dismantling of Flexible Pavements (Bituminous Courses) (By Mechanical Means)

-

-

-

... More
Dismantling of bituminous courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

110.65

-

-

... More
Dismantling of Flexible Pavements (Granular Courses) (By Manual Means)

-

-

-

... More
Dismantling of Granular courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

221

-

-

... More
Sub Head No.25 Road Restoration for Phase 11

-

-

-

... More
Compacting original ground below embankment :

-

-

-

... More
Loosening, levelling and compacting original ground below embankment to facilitate placement of first layer of embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per technical clause305 of MORT & H specifications.

276.62

-

-

... More
WBM Grade-II :

-

-

-

... More
Water Bound Macadam Grading II (Without Screening for low volume Roads/ undersigned roads).

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

55.32

-

-

... More
At Labour Rate : 60%

82.98

-

-

... More
WBM Grade-III :

-

-

-

... More
Water Bound Macadam Grading III (Without Screening for low volume Roads/ undersigned roads).Providing, laying, spreading and compacting stone aggregates of grading III to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

55.32

-

-

... More
At Labour Rate : 60%

82.98

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For WBM-II & III)

-

-

-

... More
6-10 km

110.65

-

-

... More
11-20 km

110.65

-

-

... More
21-40 km.

110.65

-

-

... More
41-60 km.

110.65

-

-

... More
61-150 km.

110.65

-

-

... More
151-220 km.

110.65

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(80 mm)

5.53

-

-

... More
For stone metal(63-45 mm)

74.69

-

-

... More
For stone metal(53-22.4 mm)

30.43

-

-

... More
Prime coat @ 0.85 kg per Sqm.

-

-

-

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 kg/Sqm complete as per technical clause 502 of MORT&H specifications.

1844.1

-

-

... More
Tack coat @ 0.40 Kg per Sqm.

-

-

-

... More
Providing and applying Tack coat

1844.1

-

-

... More
with penetration grade bitumen VG -10 using bitumen pressure distributor at the rate of 0.40 kg/Sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause

-

-

-

... More
503 of MORT&H specifications.

-

-

-

... More
Surface dressing :

-

-

-

... More
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1 kg per Sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 510 of MORTH & H specifications.

1844.1

-

-

... More
Open graded pre mix surface :

-

-

-

... More
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batch type hot mix plant with bituminous binder VG-30 @ 1.46 kg per Sqm, and laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 511 of MORT&H specifications.

1844.1

-

-

... More
Seal coat type B :

-

-

-

... More
Providing and laying of premix sand seal coat premixed in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68 kg/Sqm laid to the specified levels ,grade and cross fall complete as per technical clause 513 of MORT& H specifications.

1844.1

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface)

-

-

-

... More
6-10 km

77.45

-

-

... More
11-20 km

77.45

-

-

... More
21-40 km.

77.45

-

-

... More
41-60 km.

77.45

-

-

... More
61-150 km.

77.45

-

-

... More
151-225 km.

77.45

-

-

... More
Carriage of Fine sand : (For seal coat type-B)

-

-

-

... More
6 to 10 km.

1.11

-

-

... More
11 to 20 km.

1.11

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(13.2 mm)

60.86

-

-

... More
For stone metal(11.2 mm)

16.6

-

-

... More
Carriage of materials :

-

-

-

... More
Tar, Bitumen and other Road Binders :

-

-

-

... More
Carriage of Bitumen : Round the Trip lead is considered from Panipat Refinery.

-

-

-

... More
6 to 10 km.

8.1

-

-

... More
11 to 20 km.

8.1

-

-

... More
21 to 40 km.

8.1

-

-

... More
41 to 60 km.

8.1

-

-

... More
61 to 150 km.

8.1

-

-

... More
151 to 750 km. (350 km + 350 km)

8.1

-

-

... More
Less for Diff.Rate for Bitumen :

-

-

-

... More
Bitumen VG-10 :

4.15

-

-

... More
Bitumen VG-30 :

3.95

-

-

... More
Sub Head No.26 : Dismantling of Road work Shahi Majra

-

-

-

... More
Dismantling of Flexible Pavements (Bituminous Courses) (By Mechanical Means)

-

-

-

... More
Dismantling of bituminous courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

27

-

-

... More
Dismantling of Flexible Pavements (Granular Courses) (By Manual Means)

-

-

-

... More
Dismantling of Granular courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

54

-

-

... More
Sub Head No.27 Road Restoration for Shahi Majra

-

-

-

... More
Compacting original ground below embankment :

-

-

-

... More
Loosening, levelling and compacting original ground below embankment to facilitate placement of first layer of embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per technical clause305 of MORT & H specifications.

67.5

-

-

... More
WBM Grade-II :

-

-

-

... More
Water Bound Macadam Grading II (Without Screening for low volume Roads/ undersigned roads).

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

13.5

-

-

... More
At Labour Rate : 60%

20.25

-

-

... More
WBM Grade-III :

-

-

-

... More
Water Bound Macadam Grading III (Without Screening for low volume Roads/ undersigned roads).Providing, laying, spreading and compacting stone aggregates of grading III to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

13.5

-

-

... More
At Labour Rate : 60%

20.25

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For WBM-II & III)

-

-

-

... More
6-10 km

27

-

-

... More
11-20 km

27

-

-

... More
21-40 km.

27

-

-

... More
41-60 km.

27

-

-

... More
61-150 km.

27

-

-

... More
151-220 km.

27

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(80 mm)

1.35

-

-

... More
For stone metal(63-45 mm)

18.23

-

-

... More
For stone metal(53-22.4 mm)

7.43

-

-

... More
Prime coat @ 0.85 kg per Sqm.

-

-

-

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 kg/Sqm complete as per technical clause 502 of MORT&H specifications.

450

-

-

... More
Tack coat @ 0.40 Kg per Sqm.

-

-

-

... More
Providing and applying Tack coat

450

-

-

... More
with penetration grade bitumen VG -10 using bitumen pressure distributor at the rate of 0.40 kg/Sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause

-

-

-

... More
503 of MORT&H specifications.

-

-

-

... More
Surface dressing :

-

-

-

... More
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1 kg per Sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 510 of MORTH & H specifications.

450

-

-

... More
Open graded pre mix surface :

-

-

-

... More
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batch type hot mix plant with bituminous binder VG-30 @ 1.46 kg per Sqm, and laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 511 of MORT&H specifications.

450

-

-

... More
Seal coat type B :

-

-

-

... More
Providing and laying of premix sand seal coat premixed in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68 kg/Sqm laid to the specified levels ,grade and cross fall complete as per technical clause 513 of MORT& H specifications.

450

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface)

-

-

-

... More
6-10 km

18.9

-

-

... More
11-20 km

18.9

-

-

... More
21-40 km.

18.9

-

-

... More
41-60 km.

18.9

-

-

... More
61-150 km.

18.9

-

-

... More
151-225 km.

18.9

-

-

... More
Carriage of Fine sand : (For seal coat type-B)

-

-

-

... More
6 to 10 km.

0.27

-

-

... More
11 to 20 km.

0.27

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(13.2 mm)

14.85

-

-

... More
For stone metal(11.2 mm)

4.05

-

-

... More
Carriage of materials :

-

-

-

... More
Tar, Bitumen and other Road Binders :

-

-

-

... More
Carriage of Bitumen : Round the Trip lead is considered from Panipat Refinery.

-

-

-

... More
6 to 10 km.

1.98

-

-

... More
11 to 20 km.

1.98

-

-

... More
21 to 40 km.

1.98

-

-

... More
41 to 60 km.

1.98

-

-

... More
61 to 150 km.

1.98

-

-

... More
151 to 750 km. (350 km + 350 km)

1.98

-

-

... More
Less for Diff.Rate for Bitumen :

-

-

-

... More
Bitumen VG-10 :

1.01

-

-

... More
Bitumen VG-30 :

0.96

-

-

... More
Sub Head No.28 : Dismantling of Road work Sector 56

-

-

-

... More
Dismantling of Flexible Pavements (Bituminous Courses) (By Mechanical Means)

-

-

-

... More
Dismantling of bituminous courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

5.4

-

-

... More
Dismantling of Flexible Pavements (Granular Courses) (By Manual Means)

-

-

-

... More
Dismantling of Granular courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

11

-

-

... More
Sub Head No.29 Road Restoration for Sector 56

-

-

-

... More
Compacting original ground below embankment :

-

-

-

... More
Loosening, levelling and compacting original ground below embankment to facilitate placement of first layer of embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per technical clause305 of MORT & H specifications.

13.5

-

-

... More
WBM Grade-II :

-

-

-

... More
Water Bound Macadam Grading II (Without Screening for low volume Roads/ undersigned roads).

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

2.7

-

-

... More
At Labour Rate : 60%

4.05

-

-

... More
WBM Grade-III :

-

-

-

... More
Water Bound Macadam Grading III (Without Screening for low volume Roads/ undersigned roads).Providing, laying, spreading and compacting stone aggregates of grading III to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

2.7

-

-

... More
At Labour Rate : 60%

4.05

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For WBM-II & III)

-

-

-

... More
6-10 km

5.4

-

-

... More
11-20 km

5.4

-

-

... More
21-40 km.

5.4

-

-

... More
41-60 km.

5.4

-

-

... More
61-150 km.

5.4

-

-

... More
151-220 km.

5.4

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(80 mm)

0.27

-

-

... More
For stone metal(63-45 mm)

3.65

-

-

... More
For stone metal(53-22.4 mm)

1.49

-

-

... More
Prime coat @ 0.85 kg per Sqm.

-

-

-

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 kg/Sqm complete as per technical clause 502 of MORT&H specifications.

90

-

-

... More
Tack coat @ 0.40 Kg per Sqm.

-

-

-

... More
Providing and applying Tack coat

90

-

-

... More
with penetration grade bitumen VG -10 using bitumen pressure distributor at the rate of 0.40 kg/Sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause

-

-

-

... More
503 of MORT&H specifications.

-

-

-

... More
Surface dressing :

-

-

-

... More
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1 kg per Sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 510 of MORTH & H specifications.

90

-

-

... More
Open graded pre mix surface :

-

-

-

... More
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batch type hot mix plant with bituminous binder VG-30 @ 1.46 kg per Sqm, and laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 511 of MORT&H specifications.

90

-

-

... More
Seal coat type B :

-

-

-

... More
Providing and laying of premix sand seal coat premixed in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68 kg/Sqm laid to the specified levels ,grade and cross fall complete as per technical clause 513 of MORT& H specifications.

90

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface)

-

-

-

... More
6-10 km

3.78

-

-

... More
11-20 km

3.78

-

-

... More
21-40 km.

3.78

-

-

... More
41-60 km.

3.78

-

-

... More
61-150 km.

3.78

-

-

... More
151-225 km.

3.78

-

-

... More
Carriage of Fine sand : (For seal coat type-B)

-

-

-

... More
6 to 10 km.

0.05

-

-

... More
11 to 20 km.

0.05

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(13.2 mm)

2.97

-

-

... More
For stone metal(11.2 mm)

0.81

-

-

... More
Carriage of materials :

-

-

-

... More
Tar, Bitumen and other Road Binders :

-

-

-

... More
Carriage of Bitumen : Round the Trip lead is considered from Panipat Refinery.

-

-

-

... More
6 to 10 km.

0.4

-

-

... More
11 to 20 km.

0.4

-

-

... More
21 to 40 km.

0.4

-

-

... More
41 to 60 km.

0.4

-

-

... More
61 to 150 km.

0.4

-

-

... More
151 to 750 km. (350 km + 350 km)

0.4

-

-

... More
Less for Diff.Rate for Bitumen :

-

-

-

... More
Bitumen VG-10 :

0.2

-

-

... More
Bitumen VG-30 :

0.19

-

-

... More
Sub Head No.30 : Dismantling of Road work Mattor Area

-

-

-

... More
Dismantling of Flexible Pavements (Bituminous Courses) (By Mechanical Means)

-

-

-

... More
Dismantling of bituminous courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

5.4

-

-

... More
Dismantling of Flexible Pavements (Granular Courses) (By Manual Means)

-

-

-

... More
Dismantling of Granular courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications.

11

-

-

... More
Sub Head No.31 Road Restoration for Mattor Area

-

-

-

... More
Compacting original ground below embankment :

-

-

-

... More
Loosening, levelling and compacting original ground below embankment to facilitate placement of first layer of embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per technical clause305 of MORT & H specifications.

13.5

-

-

... More
WBM Grade-II :

-

-

-

... More
Water Bound Macadam Grading II (Without Screening for low volume Roads/ undersigned roads).

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

2.7

-

-

... More
At Labour Rate : 60%

4.05

-

-

... More
WBM Grade-III :

-

-

-

... More
Water Bound Macadam Grading III (Without Screening for low volume Roads/ undersigned roads).Providing, laying, spreading and compacting stone aggregates of grading III to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At Through Rate : 40%

2.7

-

-

... More
At Labour Rate : 60%

4.05

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For WBM-II & III)

-

-

-

... More
6-10 km

5.4

-

-

... More
11-20 km

5.4

-

-

... More
21-40 km.

5.4

-

-

... More
41-60 km.

5.4

-

-

... More
61-150 km.

5.4

-

-

... More
151-220 km.

5.4

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(80 mm)

0.27

-

-

... More
For stone metal(63-45 mm)

3.65

-

-

... More
For stone metal(53-22.4 mm)

1.49

-

-

... More
Prime coat @ 0.85 kg per Sqm.

-

-

-

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 kg/Sqm complete as per technical clause 502 of MORT&H specifications.

90

-

-

... More
Tack coat @ 0.40 Kg per Sqm.

-

-

-

... More
Providing and applying Tack coat

90

-

-

... More
with penetration grade bitumen VG -10 using bitumen pressure distributor at the rate of 0.40 kg/Sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause

-

-

-

... More
503 of MORT&H specifications.

-

-

-

... More
Surface dressing :

-

-

-

... More
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1 kg per Sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 510 of MORTH & H specifications.

90

-

-

... More
Open graded pre mix surface :

-

-

-

... More
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batch type hot mix plant with bituminous binder VG-30 @ 1.46 kg per Sqm, and laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 511 of MORT&H specifications.

90

-

-

... More
Seal coat type B :

-

-

-

... More
Providing and laying of premix sand seal coat premixed in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68 kg/Sqm laid to the specified levels ,grade and cross fall complete as per technical clause 513 of MORT& H specifications.

90

-

-

... More
Carriage of materials :

-

-

-

... More
Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish, Earth.

-

-

-

... More
Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface)

-

-

-

... More
6-10 km

3.78

-

-

... More
11-20 km

3.78

-

-

... More
21-40 km.

3.78

-

-

... More
41-60 km.

3.78

-

-

... More
61-150 km.

3.78

-

-

... More
151-225 km.

3.78

-

-

... More
Carriage of Fine sand : (For seal coat type-B)

-

-

-

... More
6 to 10 km.

0.05

-

-

... More
11 to 20 km.

0.05

-

-

... More
Less for difference in rates of materials :

-

-

-

... More
For stone metal(13.2 mm)

2.97

-

-

... More
For stone metal(11.2 mm)

0.81

-

-

... More
Carriage of materials :

-

-

-

... More
Tar, Bitumen and other Road Binders :

-

-

-

... More
Carriage of Bitumen : Round the Trip lead is considered from Panipat Refinery.

-

-

-

... More
6 to 10 km.

0.4

-

-

... More
11 to 20 km.

0.4

-

-

... More
21 to 40 km.

0.4

-

-

... More
41 to 60 km.

0.4

-

-

... More
61 to 150 km.

0.4

-

-

... More
151 to 750 km. (350 km + 350 km)

0.4

-

-

... More
Less for Diff.Rate for Bitumen :

-

-

-

... More
Bitumen VG-10 :

0.2

-

-

... More
Bitumen VG-30 :

0.19

-

-

... More
Mechanical Works :

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
Mechanical Works:

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Phase 1

-

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
Discharge 36 LPS.(2150 LPM)-40 m head

3

-

-

... More
EOT Crane :

-

-

-

... More
Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT), Main girder & End Carriage, fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches, LT wheels EN 9, Double Flanged 4 no with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.18.9/18.9.2/18.9.2.1/

-

-

-

... More
3 MT Capacity

-

-

-

... More
Span 7 M and Lift 6 M

1

-

-

... More
Providing and fixing of DI Pipes for UGSR :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS: 8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients. jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
250 mm. i/d. pipe lines laid complete.

31.48

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of IS Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage

-

-

-

... More
250mm ID DI-K9 pipes

30

-

-

... More
Providing and fixing of CI Double flanged Pipes for Manifold System in Pump House :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of C.I. Double Flanged pipes with screwed, flanged as per IS :1536, Class-B(ISI marked with the prior approval of Engineer-in-Charge) and laying the same in trenches to correct alignment and gradients, including cost of nut, bolts and rubber insertion complete including all cartage.

-

-

-

... More
150 mm. i/d. pipe lines laid complete.

4

-

-

... More
150 mm. i/d. pipe lines laid complete.

12

-

-

... More
250 mm. i/d. pipe lines laid complete.

10

-

-

... More
250 mm. i/d pipe lines laid complete.

14

-

-

... More
C.I. Specials :

-

-

-

... More
Supplying and laying C.I. specials as per IS: 1538 complete as directed by Engineer-in-Charge conforming to ISI specifications.

-

-

-

... More
C.I. specials up to 300 mm. i/d.

111.9

-

-

... More
C.I. Specials Qty. : @ 5% of Cost of Pipe/65.50

-

-

-

... More
D.I. Specials :

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I. specials up to 300 mm. i/d.

125.62

-

-

... More
D.I. Specials Qty. : @ 5% of Cost of Pipe/97.50

-

-

-

... More
Sluice Valve : (For Scour)

-

-

-

... More
Providing & fixing C.I./D.I. Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
250 mm. i/d Sluice Valves flanged.

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I. Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
250 mm. i/d Sluice Valves flanged.

1

-

-

... More
150 mm. dia. (Manifold System)

6

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
150 mm. i/d Non-return Valve.

3

-

-

... More
150 mm. i/d Non-return Valve. PN 1.6 :

3

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.4/page no.135 & 136

-

-

-

... More
150 mm. dia. PN 1.0

6

-

-

... More
For PN 1.6 add 5% extra :

6

-

-

... More
CI Puddle Collar :

-

-

-

... More
Providing and fixing in position CI Puddle collar (approx. 1 m. length) inside the wall including all material, labour as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.47/

-

-

-

... More
150 mm. dia.

4

-

-

... More
250 mm. dia.

3

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Phase 2

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
Discharge 32 LPS.(1900 LPM) 31-40 m head

3

-

-

... More
EOT Crane :

-

-

-

... More
Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT), Main girder & End Carriage, fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches, LT wheels EN 9, Double Flanged 4 No. with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.18.9/18.9.2/18.9.2.1/

-

-

-

... More
3 MT Capacity

-

-

-

... More
Span 7 M and Lift 6 M

1

-

-

... More
Providing and fixing of DI Pipes for UGSR :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS: 8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients. jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
300 mm. i/d. pipe lines laid complete.

31.98

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of IS Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage

-

-

-

... More
300mm ID DI-K9 pipes

30

-

-

... More
Providing and fixing of CI Double flanged Pipes for Manifold System in Pump House :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of C.I. Double Flanged pipes with screwed, flanged as per IS :1536, Class-B(ISI marked with the prior approval of Engineer-in-Charge) and laying the same in trenches to correct alignment and gradients, including cost of nut, bolts and rubber insertion complete including all cartage.

-

-

-

... More
150 mm. i/d. pipe lines laid complete.

4

-

-

... More
150 mm. i/d. pipe lines laid complete.

12

-

-

... More
250 mm.i/d. pipe lines laid complete.

10

-

-

... More
300 mm.i/d pipe lines laid complete.

16

-

-

... More
250 mm.i/d pipe lines laid complete.

3

-

-

... More
C.I. Specials :

-

-

-

... More
Supplying and laying C.I.specials as per IS : 1538 complete as directed by Engineer-in-Charge conforming to ISI specifications.

-

-

-

... More
C.I.specials up to 300 mm.i/d.

145.43

-

-

... More
C.I.Specials Qty. : @ 5% of Cost of Pipe/65.50

-

-

-

... More
D.I. Specials :

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I.specials above 300 mm.i/d.

107.14

-

-

... More
D.I.Specials Qty. : @ 5% of Cost of Pipe/147.50

-

-

-

... More
Sluice Valve : (For Scour)

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
300 mm.i/d Sluice Valves flanged.

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
150 mm.dia. (Manifold System)

6

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS : 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note : If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
150 mm.i/d Non-return Valve.

3

-

-

... More
150 mm.i/d Non-return Valve. PN 1.6 :

3

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.4/page no.135 & 136

-

-

-

... More
150 mm.dia. PN 1.0

6

-

-

... More
For PN 1.6 add 5% extra :

-

-

-

... More
CI Puddle Collar :

-

-

-

... More
Providing and fixing in position CI Puddle collar (approx. 1 m. length) inside the wall including all material , labour as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.47/

-

-

-

... More
150 mm. dia.

4

-

-

... More
250 mm. dia.

1

-

-

... More
300 mm. dia.

2

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Phase 5

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply, delivery at site with necessary packing, receving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
3100 LPM/52 lps & 40m head

4

-

-

... More
EOT Crane :

-

-

-

... More
Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) , Main girder & End Carriage, fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches, LT wheels EN 9, Double Flanged 4 No.with Sq.Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.18.9/18.9.2/18.9.2.1/

-

-

-

... More
3 MT Capacity

-

-

-

... More
Span 7 M and Lift 6 M

1

-

-

... More
Providing and fixing of DI Pipes for UGSR :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS:8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients.jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
300 mm.i/d. pipe lines laid complete.

31.98

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of IS Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage

-

-

-

... More
300mm ID DI-K9 pipes

30

-

-

... More
Providing and fixing of CI Double flanged Pipes for Manifold System in Pump House :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of C.I.Double Flanged pipes with screwed, flanged as per IS :1536, Class-B(ISI marked with the prior approval of Engineer-in-Charge) and laying the same in trenches to correct alignment and gradients, including cost of nut, bolts and rubber insertion complete including all cartage.

-

-

-

... More
200 mm.i/d. pipe lines laid complete. Spare Bay

4

-

-

... More
350 mm.i/d. pipe lines laid complete.

17

-

-

... More
200 mm.i/d. pipe lines laid complete.

8

-

-

... More
300 mm.i/d pipe lines laid complete.

19

-

-

... More
C.I. Specials :

-

-

-

... More
Supplying and laying C.I.specials as per IS : 1538 complete as directed by Engineer-in-Charge conforming to ISI specifications.

-

-

-

... More
C.I.specials up to 300 mm.i/d.

116.21

-

-

... More
C.I.Specials Qty. : @ 5% of Cost of Pipe/65.50

-

-

-

... More
C.I.specials above 300 mm.i/d.

86.03

-

-

... More
C.I.Specials Qty. : @ 5% of Cost of Pipe/83.50

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I.specials above 300 mm.i/d.

107.14

-

-

... More
D.I.Specials Qty. : @ 5% of Cost of Pipe/147.50

-

-

-

... More
Sluice Valve : (For Scour)

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
300 mm.i/d Sluice Valves flanged.

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm.i/d Sluice Valves flanged.

8

-

-

... More
300 mm.i/d Sluice Valves flanged.

1

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS : 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note : If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.6 as per ISI with gun metal flap :

-

-

-

... More
200 mm.i/d Non-return Valve.

4

-

-

... More
200 mm.i/d Non-return Valve. PN 1.6 :

4

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.5/19.40.6/page no.135 & 136

-

-

-

... More
200 mm.dia. PN 1.0

8

-

-

... More
For PN 1.6 add 5% extra :

8

-

-

... More
CI Puddle Collar :

-

-

-

... More
Providing and fixing in position CI Puddle collar (approx. 1 m. length) inside the wall including all material , labour as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.47/

-

-

-

... More
200 mm. dia.

5

-

-

... More
300 mm. dia.

2

-

-

... More
350 mm. dia.

1

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Sector 72 and 73

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
1100 LPM/20 lps & 40m head

2

-

-

... More
EOT Crane :

-

-

-

... More
Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) , Main girder & End Carriage, fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches, LT wheels EN 9, Double Flanged 4 No.with Sq.Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.18.9/18.9.2/18.9.2.1/

-

-

-

... More
3 MT Capacity

-

-

-

... More
Span 7 M and Lift 6 M

1

-

-

... More
Providing and fixing of DI Pipes for UGSR :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS: 8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients. jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
150 mm.i/d. pipe lines laid complete.

31.98

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of IS Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage

-

-

-

... More
150mm ID DI-K9 pipes

30

-

-

... More
Providing and fixing of CI Double flanged Pipes for Manifold System in Pump House :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of C.I.Double Flanged pipes with screwed, flanged as per IS :1536, Class-B(ISI marked with the prior approval of Engineer-in-Charge) and laying the same in trenches to correct alignment and gradients, including cost of nut, bolts and rubber insertion complete including all cartage.

-

-

-

... More
150 mm.i/d. pipe lines laid complete.

4

-

-

... More
150 mm.i/d. pipe lines laid complete.

8

-

-

... More
250 mm.i/d. pipe lines laid complete.

10

-

-

... More
150 mm.i/d pipe lines laid complete.

16

-

-

... More
250 mm.i/d pipe lines laid complete.

3

-

-

... More
C.I. Specials :

-

-

-

... More
Supplying and laying C.I.specials as per IS : 1538 complete as directed by Engineer-in-Charge conforming to ISI specifications.

-

-

-

... More
C.I.specials up to 300 mm.i/d.

94.98

-

-

... More
C.I.Specials Qty. : @ 5% of Cost of Pipe/65.50

-

-

-

... More
D.I. Specials :

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I.specials up to 300 mm.i/d.

71.5

-

-

... More
D.I.Specials Qty. : @ 5% of Cost of Pipe/97.50

-

-

-

... More
Sluice Valve : (For Scour)

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
150 mm.i/d Sluice Valves flanged.

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
150 mm.i/d Sluice Valves flanged.

5

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS : 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note : If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.6 as per ISI with gun metal flap :

-

-

-

... More
150 mm.i/d Non-return Valve.

2

-

-

... More
150 mm.i/d Non-return Valve. PN 1.6 :

2

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.5/19.40.6/page no.135 & 136

-

-

-

... More
150 mm.dia. PN 1.0

4

-

-

... More
For PN 1.6 add 5% extra :

4

-

-

... More
CI Puddle Collar :

-

-

-

... More
Providing and fixing in position CI Puddle collar (approx. 1 m. length) inside the wall including all material , labour as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.47/

-

-

-

... More
150 mm. dia.

5

-

-

... More
250 mm. dia.

1

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
At Sector 70 for Mattour Area

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
Discharge 41-50 LPS.(2450 LPM) 40 m head

3

-

-

... More
EOT Crane :

-

-

-

... More
Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) , Main girder & End Carriage, fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches, LT wheels EN 9, Double Flanged 4 No. with Sq.Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.18.9/18.9.2/18.9.2.1/

-

-

-

... More
3 MT Capacity

-

-

-

... More
Span 7 M and Lift 6 M

1

-

-

... More
Providing and fixing of DI Pipes for UGSR :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS: 8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients. jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
400 mm.i/d. pipe lines laid complete.

16.53

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of IS Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage

-

-

-

... More
400mm ID DI-K9 pipes

40

-

-

... More
Providing and fixing of CI Double flanged Pipes for Manifold System in Pump House :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of C.I.Double Flanged pipes with screwed, flanged as per IS :1536, Class-B(ISI marked with the prior approval of Engineer-in-Charge) and laying the same in trenches to correct alignment and gradients, including cost of nut, bolts and rubber insertion complete including all cartage.

-

-

-

... More
150 mm.i/d. pipe lines laid complete.

4

-

-

... More
150 mm.i/d. pipe lines laid complete.

12

-

-

... More
250 mm.i/d. pipe lines laid complete.

12

-

-

... More
250 mm.i/d pipe lines laid complete.

13

-

-

... More
C.I. Specials :

-

-

-

... More
Supplying and laying C.I.specials as per IS: 1538 complete as directed by Engineer-in-Charge conforming to ISI specifications.

-

-

-

... More
C.I.specials up to 300 mm.i/d.

115.38

-

-

... More
C.I.Specials Qty. : @ 5% of Cost of Pipe/65.50

-

-

-

... More
D.I. Specials :

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I. specials above 300 mm.i/d.

123.59

-

-

... More
D.I.Specials Qty. : @ 5% of Cost of Pipe/147.50

-

-

-

... More
Sluice Valve : (For Scour)

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
250 mm.i/d Sluice Valves flanged.

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
150 mm.dia. (Manifold System)

6

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS : 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note : If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
150 mm.i/d Non-return Valve.

3

-

-

... More
150 mm.i/d Non-return Valve. PN 1.6 :

3

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.4/page no.135 & 136

-

-

-

... More
150 mm.dia. PN 1.0

6

-

-

... More
For PN 1.6 add 5% extra :

6

-

-

... More
CI Puddle Collar :

-

-

-

... More
Providing and fixing in position CI Puddle collar (approx. 1 m. length) inside the wall including all material, labour as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.47/

-

-

-

... More
150 mm. dia.

4

-

-

... More
250 mm. dia.

2

-

-

... More
400 mm. dia.

1

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
At Sector 56 Backwash

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Non clog submersible pumping set of 2% Ni CI Cascading, Impeller CF 8M Shaft SS 410, mechanical seal with 10M Power & Control cable, 5M Galvanized Chain, 10M, 50mm MS galvanized Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. complete with all respect as per specification

-

-

-

... More
RUIDP/SOR2017/18.1

-

-

-

... More
Discharge 52 LPS.(3120 LPM) 15 m head

2

-

-

... More
Providing and fixing of DI Pipes for UGSR pump :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS: 8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients. jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
200 mm.i/d. pipe lines laid complete.

20

-

-

... More
D.I. Specials :

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I.specials up to 300 mm.i/d.

329

-

-

... More
DI D/F Bend 200mm, 90 deg.- 3 nos(31kg/piece), DI Reducer (200x150)mm-2 nos(22 kg/piece), DI Tee (200x200x200)mm-1 nos(49 kg/piece), DI D/F duck foot Bend 200mm, 90 deg.- 2 nos(47kg/piece)

-

-

-

... More
Providing and fixing 8" dia D/F M.S nipple 1.0 ft long suitable for pipe & D.I fitting

1

-

-

... More
Providing & fixing double air valve ISI Marked as per IS- 14845 including jointing all carriages complete.

-

-

-

... More
C.I Double air valve (size 40 mm)

1

-

-

... More
Providing & fixing S.S. pressure gauge complete as required complete in all respect.

-

-

-

... More
Dial diameter 150mm calibration 0-16kg

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm.dia sluice valve

2

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
200 mm.i/d Non-return Valve.

2

-

-

... More
200 mm.i/d Non-return Valve. PN 1.6 :

2

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2013/Sr.no.19.40/19.40.5/page no.126

-

-

-

... More
200 mm.dia. PN 1.0

2

-

-

... More
For PN 1.6 add 10% extra :

2

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
At Sector 56 WTP

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
Discharge 98 lps.(5833 LPM) 15-20 M HEAD

5

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
250 mm.i/d Sluice Valves flanged.

5

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
250 mm.i/d Non-return Valve.

5

-

-

... More
250 mm.i/d Non-return Valve. PN 1.6 :

5

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.5/19.40.6/page no.135 & 136

-

-

-

... More
250 mm.dia. PN 1.0

5

-

-

... More
For PN 1.6 add 5% extra :

5

-

-

... More
CI Puddle Collar :

-

-

-

... More
Providing and fixing in position CI Puddle collar (approx. 1 m. length) inside the wall including all material, labour as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.47/

-

-

-

... More
250 mm. dia.

5

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and lowering 250mm CI foot valves as per IS 4038-1986 suitable for the potable water at all level/depth including all materials, labours, hydraulic testing and commissioning as per technical specifications and as per the directions of Engineer

5

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
At Sector 57 WTP Group A

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
Discharge78 lps.(4650 LPM) 16-20M HEAD

3

-

-

... More
Providing and fixing of CI Double flanged Pipes for Manifold System in Pump House

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of C.I.Double Flanged pipes with screwed, flanged as per IS :1536, Class-B(ISI marked with the prior approval of Engineer-in-Charge) and laying the same in trenches to correct alignment and gradients, including cost of nut, bolts and rubber insertion complete including all cartage.

-

-

-

... More
200 mm.i/d. pipe lines laid complete.

18

-

-

... More
250 mm.i/d. pipe lines laid complete.

18

-

-

... More
C.I. Specials :

-

-

-

... More
Supplying and laying C.I.specials as per IS: 1538 complete as directed by Engineer-in-Charge conforming to ISI specifications.

-

-

-

... More
C.I.specials up to 300 mm.i/d.

109.26

-

-

... More
C.I.Specials Qty. : @ 5% of Cost of Pipe/97.50

-

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm.i/d Sluice Valves flanged.

3

-

-

... More
250 mm.i/d Sluice Valves flanged.

3

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
250 mm.i/d Non-return Valve.

3

-

-

... More
250 mm.i/d Non-return Valve. PN 1.6 :

3

-

-

... More
5% Extra

-

-

-

... More
200 mm.i/d Non-return Valve.

3

-

-

... More
200 mm.i/d Non-return Valve. PN 1.6 :

3

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.5/19.40.6/page no.135 & 136

-

-

-

... More
250 mm.dia. PN 1.0

6

-

-

... More
For PN 1.6 add 5% extra :

6

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and lowering 250MM CI foot valves as per IS 4038-1986 suitable for the potable water at all level/depth including all materials, labours, hydraulic testing and commissioning as per technical specifications and as per the directions of Engineer

3

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
At Sector 57 WTP Group B

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
Discharge72 lps.(4300 LPM) 16-20M HEAD

3

-

-

... More
Providing and fixing of CI Double flanged Pipes for Manifold System in Pump House

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of C.I.Double Flanged pipes with screwed, flanged as per IS :1536, Class-B(ISI marked with the prior approval of Engineer-in-Charge) and laying the same in trenches to correct alignment and gradients, including cost of nut, bolts and rubber insertion complete including all cartage.

-

-

-

... More
200 mm.i/d. pipe lines laid complete.

18

-

-

... More
250 mm.i/d. pipe lines laid complete.

18

-

-

... More
C.I. Specials :

-

-

-

... More
Supplying and laying C.I.specials as per IS: 1538 complete as directed by Engineer-in-Charge conforming to ISI specifications.

-

-

-

... More
C.I.specials up to 300 mm.i/d.

109.26

-

-

... More
C.I.Specials Qty. : @ 5% of Cost of Pipe/97.50

-

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm.i/d Sluice Valves flanged.

3

-

-

... More
250 mm.i/d Sluice Valves flanged.

3

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
250 mm.i/d Non-return Valve.

3

-

-

... More
250 mm.i/d Non-return Valve. PN 1.6 :

3

-

-

... More
5% Extra

-

-

-

... More
200 mm.i/d Non-return Valve.

3

-

-

... More
200 mm.i/d Non-return Valve. PN 1.6 :

3

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.5/19.40.6/page no.135 & 136

-

-

-

... More
200 mm.dia. PN 1.0

6

-

-

... More
For PN 1.6 add 5% extra :

6

-

-

... More
250 mm.dia. PN 1.0

6

-

-

... More
For PN 1.6 add 5% extra :

6

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and lowering 250mm CI foot valves as per IS 4038-1986 suitable for the potable water at all level/depth including all materials, labours, hydraulic testing and commissioning as per technical specifications and as per the directions of Engineer

3

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Booster Pump(Phase -10)

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification.

-

-

-

... More
RUIDP/SOR2017/19.81/page no.145 &146

-

-

-

... More
Discharge 63 lps.(3733 LPM) 40M HEAD

4

-

-

... More
Providing and fixing of CI Double flanged Pipes for Manifold System in Pump House

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of C.I.Double Flanged pipes with screwed, flanged as per IS :1536, Class-B(ISI marked with the prior approval of Engineer-in-Charge) and laying the same in trenches to correct alignment and gradients, including cost of nut, bolts and rubber insertion complete including all cartage.

-

-

-

... More
250 mm.i/d. pipe lines laid complete.

24

-

-

... More
C.I. Specials :

-

-

-

... More
Supplying and laying C.I.specials as per IS: 1538 complete as directed by Engineer-in-Charge conforming to ISI specifications.

-

-

-

... More
C.I.specials up to 300 mm.i/d.

83.62

-

-

... More
C.I.Specials Qty. : @ 5% of Cost of Pipe/97.50

-

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
250 mm.dia. (Manifold System)

4

-

-

... More
For PN 1.6 add 5 % extra :

4

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
250 mm.i/d Non-return Valve.

4

-

-

... More
250 mm.i/d Non-return Valve. PN 1.6 :

4

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.40/19.40.5/19.40.6/page no.135 & 136

-

-

-

... More
250 mm.dia. PN 1.0

8

-

-

... More
For PN 1.6 add 5% extra :

8

-

-

... More
CI Puddle Collar :

-

-

-

... More
Providing and fixing in position CI Puddle collar (approx. 1 m. length) inside the wall including all material, labour as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2017/Sr.no.19.47/

-

-

-

... More
250 mm. dia.

4

-

-

... More
Mono Block Pump :

-

-

-

... More
Providing, Installing & Commissioning Submersible Mono block Pump complete in all respect.

1

-

-

... More
GST @ 12% on Base Price :

1

-

-

... More
Providing and lowering 250mm CI foot valves as per IS 4038-1986 suitable for the potable water at all level/depth including all materials, labours, hydraulic testing and commissioning as per technical specifications and as per the directions of Engineer

4

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Sector 56 CWT

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Non clog submersible pumping set of 2% Ni CI Cascading, Impeller CF 8M Shaft SS 410, mechanical seal with 10M Power & Control cable, 5M SS Chain, 10M, 50mm SS Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. complete with all respect as per specification

-

-

-

... More
RUIDP/SOR2017/18.1

-

-

-

... More
Discharge 35 LPS.(2050 LPM) 30 m head

2

-

-

... More
Providing and fixing of DI Pipes for UGSR pump :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS: 8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients. Jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
150 mm.i/d. pipe lines laid complete.

20

-

-

... More
D.I. Specials :

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I.specials up to 300 mm.i/d.

270

-

-

... More
DI D/F Bend 150mm, 90 deg.- 3 nos(31kg/piece), DI Reducer (150x100)mm-2 nos(18 kg/piece), DI Tee (150x150x150)mm-1 nos(47 kg/piece), DI D/F duck foot Bend 150mm, 90 deg.- 2 nos(47kg/piece)

-

-

-

... More
Providing and fixing 6" dia D/F M.S nipple 1.0 ft long suitable for pipe & D.I fitting

1

-

-

... More
Providing & fixing double air valve ISI Marked as per IS- 14845 including jointing all carriages complete.

-

-

-

... More
C.I Double air valve (size 40 mm)

1

-

-

... More
Providing & fixing S.S. pressure gauge complete as required complete in all respect.

-

-

-

... More
Dial diameter 150mm calibration 0-16kg

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
150 mm.dia sluice valve

2

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS : 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
150 mm.i/d Non-return Valve.

2

-

-

... More
150 mm.i/d Non-return Valve. PN 1.6 :

2

-

-

... More
5% Extra

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Shahi majra

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Non clog submersible pumping set of 2% Ni CI Cascading, Impeller CF 8M Shaft SS 410, mechanical seal with 10M Power & Control cable, 5M SS Chain, 10M, 50mm SS Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. complete with all respect as per specification

-

-

-

... More
RUIDP/SOR2017/18.1

-

-

-

... More
Discharge 29 LPS.(1700 LPM) 35 m head

2

-

-

... More
Providing and fixing of DI Pipes for UGSR pump :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS: 8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients. Jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
150 mm.i/d. pipe lines laid complete.

20

-

-

... More
D.I. Specials :

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I.specials up to 300 mm.i/d.

270

-

-

... More
DI D/F Bend 150mm, 90 deg.- 3 nos(31kg/piece), DI Reducer (150x100)mm-2 nos(18 kg/piece), DI Tee (150x150x150)mm-1 nos(47 kg/piece), DI D/F duck foot Bend 150mm, 90 deg.- 2 nos(47kg/piece)

-

-

-

... More
Providing and fixing 6" dia D/F M.S nipple 1.0 ft long suitable for pipe & D.I fitting

1

-

-

... More
Providing & fixing double air valve ISI Marked as per IS- 14845 including jointing all carriages complete.

-

-

-

... More
C.I Double air valve (size 40 mm)

1

-

-

... More
Providing & fixing S.S. pressure gauge complete as required complete in all respect.

-

-

-

... More
Dial diameter 150mm calibration 0-16kg

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
150 mm.dia sluice valve

2

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
150 mm.i/d Non-return Valve.

2

-

-

... More
150 mm.i/d Non-return Valve. PN 1.6 :

2

-

-

... More
5% Extra

-

-

-

... More
Chlorinator for WTP 56 and at PH-10

-

-

-

... More
Providing, Installation Testing and commissioning of vacuum feed gas chlorinator with all accessories and making connection with existing pipelines required including supply and installation of trunnion roller support, axillary container valve , flexible copper connector manifold valve gas filters PRV, chlorine gas pipe with fittings diffusers lifting beam load indicator 25NB PP diaphragm valve on injector inlet and out let 32mm OD uPVC pipe for chlorine solution, 23NB GI pipe for pump suction & Delivery 25mm GM gate valve and suction & delivery 25mm GM Y type strainer on pump suction 25mm NRV on pump delivery pressure gauge with isolator valve on pump delivery and chlorine booster pump with motor of required capacity complete in all respect as per specification and as directed by the Engineer in charge Chlorinator including Chlorinator accessories.(Unit One working+Stand by ) of 2kg/hr capacity

4

-

-

... More
RUIDP SOR/2017/19.68

-

-

-

... More
Supply of Chlorine safety equipment comprising of the items with Chlorine leak detectors with two sensors self contained compressed air breathing apparatus, safety shower with eye wash , emergency tonner repair kit, protective clothing such as PVC overall , gloves and rubber boots, complete as per details specifications& the directed of the engineer.

4

-

-

... More
RUIDP SOR/2017/19.63

-

-

-

... More
Supply of chlorine Toners as per specification with roller support complete in all respect as per the direction of Engineer in charge

4

-

-

... More
RUIDP SOR/2017/19.69

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Sector 57 Backwash

-

-

-

... More
Providing and Installing Clear Water Pumping Machinery :

-

-

-

... More
Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Non clog submersible pumping set of 2% Ni CI Cascading, Impeller CF 8M Shaft SS 410, mechanical seal with 10M Power & Control cable, 5M SS Chain, 10M, 50mm SS Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. complete with all respect as per specification

-

-

-

... More
RUIDP/SOR2017/18.1

-

-

-

... More
Discharge 52 LPS.(3120 LPM) 15 m head

2

-

-

... More
Providing and fixing of DI Pipes for UGSR pump :

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS: 8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients. Jointed with nut bolts and rubber insertion joints fitted complete including all cartage

-

-

-

... More
200 mm.i/d. pipe lines laid complete.

20

-

-

... More
D.I. Specials :

-

-

-

... More
Supplying and laying DI. specials/fittings as per IS:9523- 2000 (ISI marked with the prior approval of Engineer-in- Charge), class K-12 suitable for tyton joint with external bitumen coating scaffolding, tools and plants, ropes, guys, etc. Complete in all respects and inside cement mortar lining,

-

-

-

... More
D.I.specials up to 300 mm.i/d.

329

-

-

... More
DI D/F Bend 200mm, 90 deg.- 3 nos(31kg/piece), DI Reducer (200x150)mm-2 nos(22 kg/piece), DI Tee (200x200x200)mm-1 nos(49 kg/piece), DI D/F duck foot Bend 200mm, 90 deg.- 2 nos(47kg/piece)

-

-

-

... More
Providing and fixing 8" dia D/F M.S nipple 1.0 ft long suitable for pipe & D.I fitting

1

-

-

... More
Providing & fixing double air valve ISI Marked as per IS- 14845 including jointing all carriages complete.

-

-

-

... More
C.I Double air valve (size 40 mm)

1

-

-

... More
Providing & fixing S.S. pressure gauge complete as required complete in all respect.

-

-

-

... More
Dial diameter 150mm calibration 0-16kg

1

-

-

... More
Sluice Valves :

-

-

-

... More
Providing & fixing C.I./D.I.Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm.dia sluice valve

2

-

-

... More
Non Return Valve :

-

-

-

... More
Providing & fixing ISI Marked Non-Return Valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion etc. Complete.

-

-

-

... More
Note: If Non Return valves class PN-1.6 is used instead of class PN-1.0, then 5% will be paid extra.

-

-

-

... More
Class PN 1.0 as per ISI with gun metal flap :

-

-

-

... More
200 mm.i/d Non-return Valve.

2

-

-

... More
200 mm.i/d Non-return Valve. PN 1.6 :

2

-

-

... More
5% Extra

-

-

-

... More
Dismantling Joints :

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
RUIDP/SOR SEPTEMBER 2013/Sr.no.19.40/19.40.5/page no.126

-

-

-

... More
200 mm.dia. PN 1.0

2

-

-

... More
For PN 1.6 add 10% extra :

2

-

-

... More
Air Compressor

-

-

-

... More
Providing , supplying, testing and commissioning of the 2 Nos Air compressor for WTP 57 and 2 Nos for WTP 56 with all electro mechanical components viz Motors, fittings, pressure gauge, silencers & check valve including installation as per the IS Specification with furnishing the detailed drawings and approval by the Engineer in charge

4

-

-

... More
Flash Mixer

-

-

-

... More
Providing , supplying , testing and commissioning of the 1 Nos flash mixture for WTP 56 with all electro mechanical components viz Motors, fittings including installation as per the IS Specification with furnishing the detailed drawings and approval by the Engineer in charge.

1

-

-

... More
Mixer for Floculator

-

-

-

... More
Providing , supplying fixing testing and commissioning of the 1 Nos Mixer for Floculator for WTP 57 and 3 Nos for WTP 56 with all electro mechanical components viz Motors, fittings and gear box including installation as per the IS Specification with furnishing the detailed drawings and approval by the Engineer in charge

4

-

-

... More
Motor for Alum Mixing

-

-

-

... More
Providing , supplying fixing testing and commissioning of the 03 Nos Mixer for Alum dozing for WTP 57 and 1 Nos for WTP 56 with all electro mechanical components viz Motors including installation as per the IS Specification with furnishing the detailed drawings and approval by the Engineer in charge

4

-

-

... More
Vacuum Pump

-

-

-

... More
Providing, Installation & Commissioning of vacuum pump having impeller of high quality bronze material & motor withstand wide voltage fluctuations with F class insulations and IP 55 protection. Typically used for priming the large pumps, evacuation of air from suction pipes the rates are inclusive of GST, fright charges packing installation testing, trial run and commissioning as per the IS specification and as per the direction of Engineer in charge

4

-

-

... More
Repair of Alum Dosing tank, Settling tank. Painting etc.,

-

-

-

... More
Repairing of Alum dozing Tank , Settling Tank, Painting for Electro mechanical Equipment’s, pipes and valves :

1

-

-

... More
Electrical works

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
WTP & Pump House -Sector - 56

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES:

-

-

-

... More
Supply & laying of Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC inner sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size:-

-

-

-

... More
Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade 240 sq.mm. (Three Core).

40

-

-

... More
S/E of Heat shrinkable cable end termination for 11 KV/6.6

-

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Indoor Type).

4

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Outdoor Type).

2

-

-

... More
11 kV HT Panel (drawout type):

-

-

-

... More
Supply, Installation, Testing and Commissioning of indoor type floor mounted metal clad, 11 KV Incomer VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25kA/3 and IAC A-FLR for 25kA/1 sec. Make of HT Panel, Vacuum Interrupter and VCB should be of same make. 11 KV/110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering up to 12 KV on incomer, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core ration 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class - 0.5 for metering and class 5P10 for protection, Multifunction Meter.

1

-

-

... More
RUIDP SOR 2017 66.12.1

-

-

-

... More
Supply, Installation, Testing and Commissioning of Indoor type floor mounted metal clad, 11 kV Outgoing VCB panel up to 630A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25LA/3 and IAC A-FLR for 25kA/1 sec. Make of Panel, Vacuum Interrupter and VCB should be of same make. 11 KV/ 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 kV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering up to 11 KV, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class - 0.5 for metering and class 5P10 for protection, Multifunction Meter. Outgoing up to 630 A VCB.

2

-

-

... More
RUIDP SOR 2017 66.12.3

-

-

-

... More
Transformers:

-

-

-

... More
Supply, Installation, Testing and Commissioning of copper wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type, Standard accessories like, conservator, Silica gel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain/ Flanged Rollers, Earthing terminal, Air release plug, Off load tap changer (+5% to -10% in steps of 2.5%), winding / Top oil temperature rise of 45 deg C/40 deg C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc. having max. total losses as per energy efficiency level-2 at basic insulation level conforming to Is 2025 (Part-I to Part-II), latest amended and IS 1180 Part-I: 2014 BEE star level - 1 as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating:

-

-

-

... More
RUIDP SOR 2017 66.10.2.8

-

-

-

... More
315 KVA

2

-

-

... More
O.L.T.C. with R.T.C.C. & AVR (for 11KV) RUIDP SOR 2017 66.10.4.5

2

-

-

... More
LT Panel-1 (in Pump House, WTP-56):

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 630 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 630 A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 30 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus complete as required - 5 Set

-

-

-

... More
b) Automatic Star-Delta Starter for 30 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 1 Set

-

-

-

... More
c) Automatic Star-Delta Starter for 22 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set

-

-

-

... More
d) Automatic Star-Delta Starter for 7.5 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set

-

-

-

... More
e) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 4 set

-

-

-

... More
f) 84 KVAR (10x6+5x2+4x3+1x2) heavy duty MD Capacitor bank with APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
g) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
LT Panel-2 (in Pump House, WTP-56):

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 630 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 630 A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Automatic Star-Delta Starter for 55 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 1 Set

-

-

-

... More
b) Automatic Star-Delta Starter for 45 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 1 Set

-

-

-

... More
c) Automatic Star-Delta Starter for 30 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 1 Set

-

-

-

... More
d) 250A TPN MCCB 25 KA with O/L, S/C protection and multi-function meter, indication lamps for On-Off-Trip, R-Y-B - 1 set

-

-

-

... More
e) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 4 set

-

-

-

... More
f) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 5 set.

-

-

-

... More
g) 60 KVAR (10x3+5x5+1x5) heavy duty MD Capacitor bank with APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
h) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
LT Panel-3 (in WTP-56):

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 200 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V 200 A TPN MCCB 25 KA with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 1 Set

-

-

-

... More
Outgoing:

-

-

-

... More
a) Automatic Star-Delta Starter for 15 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set.

-

-

-

... More
b) Automatic Star-Delta Starter for 11 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set.

-

-

-

... More
c) DOL starter for 3.7 KW motor with incomer MCB O/L, S/C protection, start-stop push button, remote/local selector switch, indication lamps for On-Off-Trip, R-Y-B - 4 set.

-

-

-

... More
d) DOL starter for 2.2 KW motor with incomer MCB O/L, S/C protection, start-stop push button, remote/local selector switch, indication lamps for On-Off-Trip, R-Y-B - 3 Set.

-

-

-

... More
e) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 4 set

-

-

-

... More
f) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.7

-

-

-

... More
Radiator cooled and turbo charged

-

-

-

... More
70 KVA at 0.8 pf 415V 50Hz 3-phase

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.2

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
80 to 180 KVA

1

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 25sq.mm (Three Core)

200

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 35sq.mm (Three Core)

250

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

420

-

-

... More
XLPE INSULATED ARMOURED CABLES (LOOSE):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 25sq.mm (Three Core)

145

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3.5 Core)

11

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

500

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 10sq.mm (4 Core)

40

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

10

-

-

... More
Gland for Aluminium cable 4 core size 10 sq. mm

2

-

-

... More
Gland for Aluminium cable 3.5, 4 core size 25-35 sq. mm

18

-

-

... More
Gland for Aluminium cable 3½ core size 300 sq. mm

16

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

30

-

-

... More
Aluminium cable core size 10 sq.mm. - 16 sq. mm

8

-

-

... More
Aluminium cable core size 25 sq. mm-35 sq. mm

54

-

-

... More
Aluminium cable core size 300 sq. mm.

64

-

-

... More
Supply and erection of MS perforated cable tray with DA grey paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fasteners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications 2010.

-

-

-

... More
MS perforated cable tray size 150mm x 50mm x 50mm (2mm thick)

50

-

-

... More
MS perforated cable tray size 300mm x 50mm x 50mm (2mm thick)

100

-

-

... More
MS perforated cable tray size 450mm x 50mm x 50mm (2mm thick)

50

-

-

... More
MS perforated cable tray size 50mm x 50mm x 50mm (2mm thick) L Type

200

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

16

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

100

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

250

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

750

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for HT & LT Panels to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969. Nabhi's NS Rates Electrical 2014, Page 56.

20

-

-

... More
Phase- 1 & 6

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES:

-

-

-

... More
Supply & laying of Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC inner sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size:-

-

-

-

... More
Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade 240 sq.mm. (Three Core).

30

-

-

... More
S/E of Heat shrinkable cable end termination for 11 KV/6.6

-

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Outdoor Type).

3

-

-

... More
Supply, Installation, testing and commissioning of 11 KV Double Pole structure with Air Break Switch having following specifications: RUIDP SOR 2017 66.3

1

-

-

... More
DP: Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required.

-

-

-

... More
GO: Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A, 3 phase, central post rotating double break isolator complete with MS hardware, copper moving & fixed contact, assembly of 9 Nos pin insulator, GI pipe of suitable length for operation.

-

-

-

... More
DO: 3 nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6 no pin insulators.

-

-

-

... More
LA: 3 piece non linear resistor type, lightning arrestor of approved make suitable for 3 wire, 11kv OH line with rated voltage of 9kv rms & nominal discharge current rating of 5 KA & complete with galvanized clamping arrangements GI bolts, nuts, washer etc. as required.

-

-

-

... More
JUMPERS: 3 no 11kv ACSR conductors mounted on pin type insulators as required.

-

-

-

... More
GENERAL: The GO shall be operated by hand operated liver properly earthed with provision for locking mounted at 3'.

-

-

-

... More
Transformers:

-

-

-

... More
Supply, Installation, Testing and Commissioning of copper wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type, Standard accessories like, conservator, Silica gel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain/ Flanged Rollers, Earthing terminal, Air release plug, Off load tap changer (+5% to -10% in steps of 2.5%), winding / Top oil temperature rise of 45 deg C/40 deg C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc. having max. total losses as per energy efficiency level-2 at basic insulation level conforming to Is 2025 (Part-I to Part-II), latest amended and IS 1180 Part-I: 2014 BEE star level - 1 as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating:

-

-

-

... More
RUIDP SOR 2017 66.10.2.5

-

-

-

... More
160 KVA

1

-

-

... More
Providing, fixing & erection of Transformer foundation including 6SWG wire mesh fencing all around the transformer with post, frame, gate & their foundation, structure and other civil related work complete as required (item to be executed as per CSR/DSR/RUIDP/SOR).

1

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.10

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
125 KVA at 0.8 pf 415V 50Hz 3-phase

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.2

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
80 to 180 KVA

1

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 315 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 315A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 30 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus., complete as required - 3 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set.

-

-

-

... More
d) 35 KVAR (10x2+5x2+1x5) heavy duty MD Capacitor bank with 10 step APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 10sq.mm (Twin Core)

100

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 120sq.mm (3 ½ Core)

50

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

30

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 6sq.mm (4 Core)

45

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 70sq.mm (3 Core)

85

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

8

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 6 sq. mm

4

-

-

... More
Gland for Aluminium cable 4 core size 10 sq. mm

8

-

-

... More
Gland for Aluminium cable 3.5, 4 core size 70 sq. mm

4

-

-

... More
Gland for Aluminium cable 3½ core size 95-120 sq. mm

2

-

-

... More
Gland for Aluminium cable 3½ core size 300 sq. mm

2

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

40

-

-

... More
Aluminium cable core size 10 sq.mm. - 16 sq. mm

16

-

-

... More
Aluminium cable core size 70 sq. mm.

12

-

-

... More
Aluminium cable core size 120 sq. mm.

8

-

-

... More
Aluminium cable core size 300 sq. mm.

8

-

-

... More
Supply and erection of MS perforated cable tray with DA grey paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fasteners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications 2010.

-

-

-

... More
MS perforated cable tray size 150mm x 50mm x 50mm (2mm thick)

40

-

-

... More
MS perforated cable tray size 50mm x 50mm x 50mm (2mm thick) L Type

50

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

12

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

80

-

-

... More
DSR(B&M)2016 5.11

-

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR(B&M)2016 5.15

150

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR(B&M)2016 5.16

150

-

-

... More
Wiring, Lighting & Accessories:

-

-

-

... More
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES :

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm. /25 mm. dia. (1.6 mm. thick) ISI Marked, recessed in wall etc., complete with powder coated/anodised concealed metal boxes required for having electronic fan regulators (socket size), bell push, electronic buzzer, 3 pin 6 Amp., 3 pin 16/20 Amp. Sockets and 6 Amp/16/20 Amp. Switches (flush piano type accessories) etc. and covered with brown Bakelite white glazed translucent backside painted sheet 3 mm. thick etc. & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (for Fan Box and Electronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and. filling up of chases.:

-

-

-

... More
Wiring fan point with sheet metal fan box ( shape hexagonal ) in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade with step type electronic fan regulator 100 watts ( socket size)

6

-

-

... More
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 Sqm. 1100 volts grade.

12

-

-

... More
Wiring 3 pin 6 Amp. Wall socket point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sq.mm., 1100 volts grade.

6

-

-

... More
Wiring 3 pin 16/20 amp. Power plug control and switch.

6

-

-

... More
Supply and errection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and errection of pipe or casing.

-

-

-

... More
PVC insulated copper conductor single core FR cable (ISI marked) overall 2.5 sq.mm.1100 volts grade.

200

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/TPN MCB's/isolators for incoming and DP/SP & N/Single Pole MCB's/CBO/RCCB's for outgoing 6 way each

1

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

1

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker four pole 6 to 32 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply.

1

-

-

... More
Miniature circuit breaker double pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply.

2

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

12

-

-

... More
Providing and fixing of LED indoor light fixture 18 W as per RUIDP SOR code no. 57.26.3 complete as required at site.

10

-

-

... More
RUIDP SOR 2017 57.26.3

-

-

-

... More
Providing and fixing LED Street light fixture 30-40 Watt (as per RUIDP SOR code no. 58.31.1.2) on single arm bracket (as per CSR code no. 33.31 A (i) for exterior illumination of Pump House complete as required at site.

2

-

-

... More
RUIDP SOR 58.31.1.2 + CSR 33.29 B(i)

-

-

-

... More
Providing and erection of 3-stepped steel tubular swaged and welded pole 7 metre length (as per CSR code no. 33.31 A(i)) with single arm bracket (as per CSR code no. 33.29 B (i)) & LED Street light fixture 60 watt (as per RUIDP SOR code no. 58.31.1.4) complete with required civil work etc. & as required at site.

4

-

-

... More
Providing and fixing of heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust Fan including making connections testing etc. as required.

-

-

-

... More
SOR RUIDP 2017 55.9.3

-

-

-

... More
450 mm Sweep (900 RPM)

4

-

-

... More
P&F of capacitor start, three speed wall mounting/ cabin fan of following sweep with the help of anchor bolts including making connection testing etc. as required.

-

-

-

... More
SOR RUIDP 2017 55.12.1

-

-

-

... More
400 mm sweep (oscillating type)

2

-

-

... More
Safety items for Electrical Room/ Pump House:

-

-

-

... More
Providing & fixing of shock treatment chart on wooden frame with 5 mm thick glass (Approx. Front Area 1.20 Sqm) Nabhi's NS Rates Electrical 2014, page 56

1

-

-

... More
Providing & fixing with bracket/supports etc. wall mounted Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5 Kg capacity.

1

-

-

... More
RUIDP SOR 2017 67.39.4

-

-

-

... More
Providing & fixing of First Aid Box Confirming to IS: 2217 - 1963. Nabhi's NS Rates Electrical 2014, Page 56

1

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969. Nabhi's NS Rates Electrical 2014, Page 56

4

-

-

... More
Providing of insulating hand gloves as Per Relevant IS Code

1

-

-

... More
Providing & fixing of self contained type LED emergency light with 2 Hrs. backup.

3

-

-

... More
Phase- 3, 4 & 5

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES:

-

-

-

... More
Supply & laying of Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC inner sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size:-

-

-

-

... More
Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade 240 sq.mm. (Three Core).

30

-

-

... More
S/E of Heat shrinkable cable end termination for 11 KV/6.6

-

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Indoor Type).

3

-

-

... More
Supply, Installation, testing and commissioning of 11 KV Double Pole structure with Air Break Switch having following specifications: RUIDP SOR 2017 66.3

1

-

-

... More
DP: Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required.

-

-

-

... More
GO: Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A, 3 phase, central post rotating double break isolator complete with MS hardware, copper moving & fixed contact, assembly of 9 Nos pin insulator, GI pipe of suitable length for operation.

-

-

-

... More
DO: 3 nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6 no pin insulators.

-

-

-

... More
LA: 3 piece non linear resistor type, lightning arrestor of approved make suitable for 3 wire, 11kv OH line with rated voltage of 9kv rms & nominal discharge current rating of 5 KA & complete with galvanized clamping arrangements GI bolts, nuts, washer etc. as required.

-

-

-

... More
JUMPERS: 3 no 11kv ACSR conductors mounted on pin type insulators as required.

-

-

-

... More
GENERAL: The GO shall be operated by hand operated liver properly earthed with provision for locking mounted at 3'.

-

-

-

... More
Transformers:

-

-

-

... More
Supply, Installation, Testing and Commissioning of copper wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type, Standard accessories like, conservator, Silica gel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain/ Flanged Rollers, Earthing terminal, Air release plug, Off load tap changer (+5% to -10% in steps of 2.5%), winding / Top oil temperature rise of 45 deg C/40 deg C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc. having max. total losses as per energy efficiency level-2 at basic insulation level conforming to Is 2025 (Part-I to Part-II), latest amended and IS 1180 Part-I: 2014 BEE star level - 1 as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating:

-

-

-

... More
RUIDP SOR 2017 66.10.2.6

-

-

-

... More
200 KVA

1

-

-

... More
Providing, fixing & erection of Transformer foundation including 6SWG wire mesh fencing all around the transformer with post, frame, gate & their foundation, structure and other civil related work complete as required (item to be executed as per CSR/DSR/RUIDP/SOR).

1

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.14

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
200 KVA at 0.8 pf 415V 50Hz 3-phase

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.3

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
200 to 500 KVA

1

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 400 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 400A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 37 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus., complete as required - 4 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 4 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 4 set.

-

-

-

... More
d) 50 KVAR (10x4+2x4+1x2) heavy duty MD Capacitor bank with 11 step APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 10sq.mm (Twin Core)

100

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 120sq.mm (3 ½ Core)

50

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

100

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 6sq.mm (4 Core)

45

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 50sq.mm (3 Core)

130

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

8

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 6 sq. mm

4

-

-

... More
Gland for Aluminium cable 4 core size 10 sq. mm

8

-

-

... More
Gland for Aluminium cable 3.5, 4 core size 50 sq. mm

8

-

-

... More
Gland for Aluminium cable 3½ core size 95-120 sq. mm

2

-

-

... More
Gland for Aluminium cable 3½ core size 300 sq. mm

2

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

40

-

-

... More
Aluminium cable core size 10 sq.mm. - 16 sq. mm

16

-

-

... More
Aluminium cable core size 70 sq. mm.

24

-

-

... More
Aluminium cable core size 120 sq. mm.

8

-

-

... More
Aluminium cable core size 300 sq. mm.

8

-

-

... More
Supply and erection of MS perforated cable tray with DA grey paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fasteners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications 2010.

-

-

-

... More
MS perforated cable tray size 150mm x 50mm x 50mm (2mm thick)

40

-

-

... More
MS perforated cable tray size 50mm x 50mm x 50mm (2mm thick) L Type

50

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

12

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

80

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

150

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Ref. DSR (E&M) 2016, 5.16

150

-

-

... More
Wiring, Lighting & Accessories:

-

-

-

... More
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES :

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked, recessed in wall etc. Complete with powder coated/anodised concealed metal boxes required for having electronic fan regulators ( socket size), bell push, electronic buzzer, 3 pin 6 Amp., 3 pin 16/20 Amp. Sockets and 6 Amp/16/20 Amp. Switches (flush piano type accessories) etc. and covered with brown Bakelite white glazed translucent backside painted sheet 3 mm. thick etc. & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (for Fan Box and Electronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and. filling up of chases.:

-

-

-

... More
Wiring fan point with sheet metal fan box ( shape hexagonal ) in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade with step type electronic fan regulator 100 watts ( socket size)

6

-

-

... More
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 Sqm. 1100 volts grade.

12

-

-

... More
Wiring 3 pin 6 Amp. Wall socket point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sq.mm., 1100 volts grade.

6

-

-

... More
Wiring 3 pin 16/20 amp. Power plug control and switch.

6

-

-

... More
Supply and errection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and errection of pipe or casing.

-

-

-

... More
PVC insulated copper conductor single core FR cable (ISI marked) overall 2.5 sq.mm.1100 volts grade.

200

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/TPN MCB's/isolators for incoming and DP/SP & N/Single Pole MCB's/CBO/RCCB's for outgoing 6 way each

1

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

1

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker four pole 6 to 32 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply.

1

-

-

... More
Miniature circuit breaker double pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply.

2

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

12

-

-

... More
Providing and fixing of LED indoor light fixture 18 W as per RUIDP SOR code no. 57.26.3 complete as required at site.

10

-

-

... More
RUIDP SOR 2017 57.26.3

-

-

-

... More
Providing and fixing LED Street light fixture 30-40 Watt (as per RUIDP SOR code no. 58.31.1.2) on single arm bracket (as per CSR code no. 33.31 A (i)) for exterior illumination of Pump House complete as required at site.

2

-

-

... More
RUIDP SOR 58.31.1.2 + CSR 33.29 B(i)

-

-

-

... More
Providing and erection of 3-stepped steel tubular swaged and welded pole 7 metre length (as per CSR code no. 33.31 A(i)) with single arm bracket (as per CSR code no. 33.29 B (i)) & LED Street light fixture 60 watt (as per RUIDP SOR code no. 58.31.1.4) complete with required civil work etc. & as required at site.

4

-

-

... More
Providing and fixing of heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust Fan including making connections testing etc. as required.

-

-

-

... More
SOR RUIDP 2017 55.9.3

-

-

-

... More
450 mm Sweep (900 RPM)

4

-

-

... More
P&F of capacitor start, three speed wall mounting/ cabin fan of following sweep with the help of anchor bolts including making connection testing etc. as required.

-

-

-

... More
RUIDP SOR 2017 55.12.1

-

-

-

... More
400 mm sweep (oscillating type)

2

-

-

... More
Safety items for Electrical Room/ Pump House:

-

-

-

... More
Providing & fixing of shock treatment chart on wooden frame with 5 mm thick glass (Approx. Front Area 1.20 Sqm) Nabhi's NS Rates Electrical 2014, page 56

1

-

-

... More
Providing & fixing with bracket/supports etc. wall mounted Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5 Kg capacity.

1

-

-

... More
RUIDP SOR 2017 67.39.4

-

-

-

... More
Providing & fixing of First Aid Box Confirming to IS: 2217 - 1963. Nabhi's NS Rates Electrical 2014, Page 56

1

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969. Nabhi's NS Rates Electrical 2014, Page 56

4

-

-

... More
Providing of insulating hand gloves as Per Relevant IS Code

1

-

-

... More
Providing & fixing of self-contained type LED emergency light with 2 Hrs. backup.

3

-

-

... More
Phase- 2

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES:

-

-

-

... More
Supply & laying of Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC inner sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size:-

-

-

-

... More
Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade 240 sq.mm. (Three Core).

30

-

-

... More
S/E of Heat shrinkable cable end termination for 11 KV/6.6

-

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Outdoor Type).

3

-

-

... More
Supply, Installation, testing and commissioning of 11 KV Double Pole structure with Air Break Switch having following specifications: RUIDP SOR 2017 66.3

1

-

-

... More
DP: Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required.

-

-

-

... More
GO: Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A, 3 phase, central post rotating double break isolator complete with MS hardware, copper moving & fixed contact, assembly of 9 Nos pin insulator, GI pipe of suitable length for operation.

-

-

-

... More
DO: 3 nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6 no pin insulators.

-

-

-

... More
LA: 3 piece non-linear resistor type, lightning arrestor of approved make suitable for 3 wire, 11kv OH line with rated voltage of 9kv rms & nominal discharge current rating of 5 KA & complete with galvanized clamping arrangements GI bolts, nuts, washer etc. as required.

-

-

-

... More
JUMPERS: 3 no 11kv ACSR conductors mounted on pin type insulators as required.

-

-

-

... More
GENERAL: The GO shall be operated by hand operated liver properly earthed with provision for locking mounted at 3'.

-

-

-

... More
Transformers:

-

-

-

... More
Supply, Installation, Testing and Commissioning of copper wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type, Standard accessories like, conservator, Silica gel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain/ Flanged Rollers, Earthing terminal, Air release plug, Off load tap changer (+5% to -10% in steps of 2.5%), winding / Top oil temperature rise of 45 deg C/40 deg C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc. having max. total losses as per energy efficiency level-2 at basic insulation level conforming to Is 2025 (Part-I to Part-II), latest amended and IS 1180 Part-I: 2014 BEE star level - 1 as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating:RUIDP SOR 2017 66.10.2.5

-

-

-

... More
160 KVA

1

-

-

... More
Providing, fixing & erection of Transformer foundation including 6SWG wire mesh fencing all around the transformer with post, frame, gate & their foundation, structure and other civil related work complete as required (item to be executed as per CSR/DSR/RUIDP/SOR).

1

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self-regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, and all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.10

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
125 KVA at 0.8 pf 415V 50Hz 3-phase.

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.22

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
80 to 180 KVA

1

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 315 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 315A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 30 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus., complete as required - 3 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set.

-

-

-

... More
d) 35 KVAR (10x2+5x2+1x5) heavy duty MD Capacitor bank with 10 step APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 10sq.mm (Twin Core)

100

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 120sq.mm (3 ½ Core)

50

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

100

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 6sq.mm (4 Core)

45

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 70sq.mm (3 Core)

55

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

8

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 6 sq. mm

4

-

-

... More
Gland for Aluminium cable 4 core size 10 sq. mm

4

-

-

... More
Gland for Aluminium cable 3.5, 4 core size 70 sq. mm

4

-

-

... More
Gland for Aluminium cable 3½ core size 95-120 sq. mm

2

-

-

... More
Gland for Aluminium cable 3½ core size 300 sq. mm

2

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

32

-

-

... More
Aluminium cable core size 10 sq.mm. - 16 sq. mm

16

-

-

... More
Aluminium cable core size 70 sq. mm

12

-

-

... More
Aluminium cable core size 120 sq. mm.

8

-

-

... More
Aluminium cable core size 300 sq. mm.

8

-

-

... More
Supply and erection of MS perforated cable tray with DA grey paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fasteners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications 2010.

-

-

-

... More
MS perforated cable tray size 150mm x 50mm x 50mm (2mm thick)

40

-

-

... More
MS perforated cable tray size 50mm x 50mm x 50mm (2mm thick) L Type

50

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

12

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

80

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

150

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

150

-

-

... More
Wiring, Lighting & Accessories:

-

-

-

... More
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES :

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked, recessed in wall etc. Complete with powder coated/anodised concealed metal boxes required for having electronic fan regulators ( socket size), bell push, electronic buzzer, 3 pin 6 Amp., 3 pin 16/20 Amp. Sockets and 6 Amp/16/20 Amp. Switches (flush piano type accessories) etc. and covered with brown Bakelite white glazed translucent backside painted sheet 3 mm. thick etc. & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (for Fan Box and Electronic Buzzer), PVC Bush, Steel hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases.:

-

-

-

... More
Wiring fan point with sheet metal fan box ( shape hexagonal ) in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade with step type electronic fan regulator 100 watts ( socket size)

6

-

-

... More
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 Sqm. 1100 volts grade.

12

-

-

... More
Wiring 3 pin 6 Amp. Wall socket point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sq.mm., 1100 volts grade.

6

-

-

... More
Wiring 3 pin 16/20 amp. Power plug control and switch.

6

-

-

... More
Supply and errection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and errection of pipe or casing.

-

-

-

... More
PVC insulated copper conductor single core FR cable (ISI marked) overall 2.5 sq.mm.1100 volts grade.

200

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/TPN MCB's/isolators for incoming and DP/SP & N/Single Pole MCB's/CBO/RCCB's for outgoing 6 way each

1

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

1

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker four pole 6 to 32 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply.

1

-

-

... More
Miniature circuit breaker double pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply.

2

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

12

-

-

... More
Providing and fixing of LED indoor light fixture 18 W as per RUIDP SOR code no. 57.26.3 complete as required at site.

10

-

-

... More
RUIDP SOR 2017 57.26.3

-

-

-

... More
Providing and fixing LED Street light fixture 30-40 Watt (as per RUIDP SOR code no. 58.31.1.2) on single arm bracket (as per CSR code no. 33.31 A (i)) for exterior illumination of Pump House complete as required at site.

2

-

-

... More
RUIDP SOR 58.31.1.2 + CSR 33.29 B(i)

-

-

-

... More
Providing and erection of 3-stepped steel tubular swaged and welded pole 7 metre length (as per CSR code no. 33.31 A(i)) with single arm bracket (as per CSR code no. 33.29 B (i)) & LED Street light fixture 60 watt (as per RUIDP SOR code no. 58.31.1.4) complete with required civil work etc. & as required at site.

4

-

-

... More
Providing and fixing of heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust Fan including making connections testing etc. as required.

-

-

-

... More
SOR RUIDP 2017 55.9.3

-

-

-

... More
450 mm Sweep (900 RPM)

4

-

-

... More
P&F of capacitor start, three speed wall mounting/ cabin fan of following sweep with the help of anchor bolts including making connection testing etc. as required.

-

-

-

... More
SOR RUIDP 2017 55.12.1

-

-

-

... More
400 mm sweep (oscillating type)

2

-

-

... More
Safety items for Electrical Room/ Pump House:

-

-

-

... More
Providing & fixing of shock treatment chart on wooden frame with 5 mm thick glass (Approx. Front Area 1.20 Sqm) Nabhi's NS Rates Electrical 2014, page 56

1

-

-

... More
Providing & fixing with bracket/supports etc. wall mounted Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5 Kg capacity.

1

-

-

... More
RUIDP SOR 2017 67.39.4

-

-

-

... More
Providing & fixing of First Aid Box Confirming to IS: 2217 - 1963. Nabhi's NS Rates Electrical 2014, Page 56

1

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969. Nabhi's NS Rates Electrical 2014, Page 56

4

-

-

... More
Providing of insulating hand gloves as Per Relevant IS Code

1

-

-

... More
Providing & fixing of self-contained type LED emergency light with 2 Hrs. backup.

3

-

-

... More
Phase- 7

-

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 400 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 400A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 55 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus., complete as required - 2 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set.

-

-

-

... More
d) 35 KVAR (10x2+5x2+2x2+1x1) heavy duty MD Capacitor bank with APFC relay, MCCB, contactor, necessary protection complete as required - 1 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self-regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.11

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
140 KVA at 0.8 of 415V 50Hz 3-phase.

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.2

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
80 to 180 KVA

1

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

6

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

30

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

60

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

50

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 120sq.mm (3 ½ Core)

50

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checkouts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

6

-

-

... More
Gland for Aluminium cable 3½ core size 95-120 sq. mm

2

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

18

-

-

... More
Aluminium cable core size 120 sq. mm.

8

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969Nabhi's NS Rates Electrical 2014, Page 56

2

-

-

... More
WTP & Pump House, Sector -57

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES:

-

-

-

... More
Supply & laying of Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC inner sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size:-

-

-

-

... More
Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade 240 sq.mm. (Three Core).

30

-

-

... More
S/E of Heat shrinkable cable end termination for 11 KV/6.6

-

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Indoor Type).

2

-

-

... More
11 kV HT Panel (draw out type):

-

-

-

... More
Supply, Installation, Testing and Commissioning of indoor type floor mounted metal clad, 11 KV Incomer cum outgoing VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25kA/3 and IAC A-FLR for 25kA/1 sec. Make of HT Panel, Vacuum Interrupter and VCB should be of same make. 11 KV/110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering up to 12 KV on incomer, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core ration 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class - 0.5 for metering and class 5P10 for protection, Multifunction Meter. RUIDP SOR 2017 66.12.1

1

-

-

... More
LT Panel-1 (in Switchgear Room, WTP-57):

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 800 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 800A ACB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) 630A TPN MCCB 25 KA with O/L, S/C protection and multi-function meter, indication lamps for On-Off-Trip, R-Y-B - 1 set

-

-

-

... More
b) 250A TPN MCCB 25 KA with O/L, S/C protection and multi-function meter, indication lamps for On-Off-Trip, R-Y-B - 1 set

-

-

-

... More
c) 63A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 2 set

-

-

-

... More
d) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 2 set

-

-

-

... More
e) 111 KVAR (20x2+10x4+5x6+1x1) heavy duty MD Capacitor bank with APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
f) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
LT Panel-2 (in Pump House, WTP-57):

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 630 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 630A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 1 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 30 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus complete as required - 3 Set

-

-

-

... More
b) Digital Soft Starter 22 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus complete as required - 3 Set

-

-

-

... More
c) Automatic Star-Delta Starter for 30 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 1 Set.

-

-

-

... More
d) Automatic Star-Delta Starter for 18.5 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set.

-

-

-

... More
e) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 4 set.

-

-

-

... More
f) 32A MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 6 set.

-

-

-

... More
g) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
LT Panel-3 (in WTP-57):

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 200 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V 200 A TPN MCCB 25 KA with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 1 Set

-

-

-

... More
Outgoing:

-

-

-

... More
a) Automatic Star-Delta Starter for 22 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set.

-

-

-

... More
b) Automatic Star-Delta Starter for 15 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set.

-

-

-

... More
c) DOL starter for 3.7 KW motor with incomer MCB O/L, S/C protection, start-stop push button, remote/local selector switch, indication lamps for On-Off-Trip, R-Y-B - 1 set.

-

-

-

... More
d) DOL starter for 2.2 KW motor with incomer MCB O/L, S/C protection, start-stop push button, remote/local selector switch, indication lamps for On-Off-Trip, R-Y-B - 3 Set.

-

-

-

... More
e) DOL starter for 0.75 KW motor with incomer MCB O/L, S/C protection, start-stop push button, remote/local selector switch, indication lamps for On-Off-Trip, R-Y-B - 3 Set.

-

-

-

... More
f) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 4 set.

-

-

-

... More
g) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 25sq.mm (Three Core)

400

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

460

-

-

... More
XLPE INSULATED ARMOURED CABLES (LOOSE):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 25sq.mm (Three Core)

180

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

130

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage upto and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

400

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 10sq.mm (4 Core)

40

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

10

-

-

... More
Gland for Aluminium cable 4 core size 10 sq. mm

2

-

-

... More
Gland for Aluminium cable 3.5, 4 core size 25-35 sq. mm

20

-

-

... More
Gland for Aluminium cable 3½ core size 300 sq. mm

14

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

30

-

-

... More
Aluminium cable core size 10 sq.mm. - 16 sq. mm

8

-

-

... More
Aluminium cable core size 25-35 sq. mm.

60

-

-

... More
Aluminium cable core size 300 sq. mm.

56

-

-

... More
Supply and erection of MS perforated cable tray with DA grey paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fasteners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications 2010.

-

-

-

... More
MS perforated cable tray size 150mm x 50mm x 50mm (2mm thick)

50

-

-

... More
MS perforated cable tray size 300mm x 50mm x 50mm (2mm thick)

100

-

-

... More
MS perforated cable tray size 450mm x 50mm x 50mm (2mm thick)

50

-

-

... More
MS perforated cable tray size 50mm x 50mm x 50mm (2mm thick) L Type

200

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

12

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

100

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

150

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

750

-

-

... More
Motor for Alum dosing:

-

-

-

... More
Supply, Installation, Testing, Commissioning of Horizontal Foot Mounted IE2 type 6 Pole TEFC, S1 duty, IP-55, 415 Volts Squirrel cage Enclosure confirming to protection IP55 suitable for operation on 415 +/- 10%V, 3 Phase 50 HZ +/- 5% AC supply with ambient 50 C class F insulation with temperature rise limited to class B Induction Motors confirming to IS-325 & IS 12615 - 2011 with latest amendments. Of the following rating.

-

-

-

... More
RUIDP SOR 2017 64.3

-

-

-

... More
2.2 KW.RUIDP SOR 2017 64.3

1

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969Nabhi's NS Rates Electrical 2014, Page 56

20

-

-

... More
Sector- 72 & 73

-

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self-regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, and all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.4

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
40 KVA at 0.8 of 415V 50Hz 3-phase

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.1

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
25 to 63.5 KVA

1

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 100 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 100A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Automatic Star-Delta Starter for 15 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set.

-

-

-

... More
d) 6 KVAR heavy duty MD Capacitor with MCB, capacitor duty contactor, necessary protection complete as required - 2 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 10sq.mm (Twin Core)

100

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 120sq.mm (3 ½ Core)

50

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

30

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 6sq.mm (4 Core)

45

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 70sq.mm (3 Core)

55

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

8

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 6 sq. mm

4

-

-

... More
Gland for Aluminium cable 4 core size 10 sq. mm

8

-

-

... More
Gland for Aluminium cable 3.5, 4 core size 70 sq. mm

4

-

-

... More
Gland for Aluminium cable 3½ core size 95-120 sq. mm

2

-

-

... More
Gland for Aluminium cable 3½ core size 300 sq. mm

2

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

40

-

-

... More
Aluminium cable core size 10 sq.mm. - 16 sq. mm

16

-

-

... More
Aluminium cable core size 70 sq. mm.

12

-

-

... More
Aluminium cable core size 120 sq. mm.

8

-

-

... More
Aluminium cable core size 300 sq. mm.

8

-

-

... More
Supply and erection of MS perforated cable tray with DA grey paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fasteners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications 2010.

-

-

-

... More
MS perforated cable tray size 150mm x 50mm x 50mm (2mm thick)

40

-

-

... More
MS perforated cable tray size 50mm x 50mm x 50mm (2mm thick) L Type

50

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

12

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

80

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

150

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

150

-

-

... More
Wiring, Lighting & Accessories:

-

-

-

... More
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES :

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked, recessed in wall etc. Complete with powder coated/anodised concealed metal boxes required for having electronic fan regulators ( socket size), bell push, electronic buzzer, 3 pin 6 Amp., 3 pin 16/20 Amp. Sockets and 6 Amp/16/20 Amp. Switches (flush piano type accessories) etc. and covered with brown bakelite white glazed translucent backside painted sheet 3 mm.thick etc. & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (for Fan Box and Electronic Buzzer), PVC Bush, Steel hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and. filling up of chases.:

-

-

-

... More
Wiring fan point with sheet metal fan box ( shape hexagonal ) in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade with step type electronic fan regulator 100 watts ( socket size)

6

-

-

... More
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 Sqm. 1100 volts grade.

12

-

-

... More
Wiring 3 pin 6 Amp. Wall socket point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sq.mm., 1100 volts grade.

6

-

-

... More
Wiring 3 pin 16/20 amp. Power plug control and switch.

6

-

-

... More
Supply and errection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and errection of pipe or casing.

-

-

-

... More
PVC insulated copper conductor single core FR cable (ISI marked) overall 2.5 sq.mm.1100 volts grade.

200

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/TPN MCB's/isolators for incoming and DP/SP & N/Single Pole MCB's/CBO/RCCB's for outgoing 6 way each

1

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

1

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker four pole 6 to 32 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply.

1

-

-

... More
Miniature circuit breaker double pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply.

2

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

12

-

-

... More
Providing and fixing of LED indoor light fixture 18 W as per RUIDP SOR code no. 57.26.3 complete as required at site.

10

-

-

... More
RUIDP SOR 2017 57.26.3

-

-

-

... More
Providing and fixing LED Street light fixture 30-40 Watt (as per RUIDP SOR code no. 58.31.1.2) on single arm bracket (as per CSR code no. 33.31 A (i) for exterior illumination of Pump House complete as required at site.

2

-

-

... More
Providing and erection of 3-stepped steel tubular swaged and welded pole 7 metre length (as per CSR code no. 33.31 A(i)) with single arm bracket (as per CSR code no. 33.29 B (i)) & LED Street light fixture 60 watt (as per RUIDP SOR code no. 58.31.1.4) complete with required civil work etc. & as required at site.

4

-

-

... More
Providing and fixing of heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust Fan including making connections testing etc. as required.

-

-

-

... More
SOR RUIDP 2017 55.9.3

-

-

-

... More
450 mm Sweep (900 RPM)

4

-

-

... More
P&F of capacitor start, three speed wall mounting/ cabin fan of following sweep with the help of anchor bolts including making connection testing etc. as required.

-

-

-

... More
SOR RUIDP 2017 55.12.1

-

-

-

... More
400 mm sweep (oscillating type)

2

-

-

... More
Safety items for Electrical Room/ Pump House:

-

-

-

... More
Providing & fixing of shock treatment chart on wooden frame with 5 mm thick glass (Approx. Front Area 1.20 Sqm) Nabhi's NS Rates Electrical 2014, page 56

1

-

-

... More
Providing & fixing with bracket/supports etc. wall mounted Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5 Kg capacity.

1

-

-

... More
RUIDP SOR 2017 67.39.4

-

-

-

... More
Providing & fixing of First Aid Box Confirming to IS: 2217 - 1963. Nabhi's NS Rates Electrical 2014, Page 56

1

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969. Nabhi's NS Rates Electrical 2014, Page 56

4

-

-

... More
Providing of insulating hand gloves as Per Relevant IS Code

1

-

-

... More
Providing & fixing of self-contained type LED emergency light with 2 Hrs. backup.

3

-

-

... More
Sector -71

-

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 250 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 250A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 37 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus., complete as required - 2 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set.

-

-

-

... More
d) 27 KVAR (10x2+2x1+1x5) heavy duty MD Capacitor bank with APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

6

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

18

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969Nabhi's NS Rates Electrical 2014, Page 56

2

-

-

... More
Mattour

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES:

-

-

-

... More
Supply & laying of Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC inner sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size:-

-

-

-

... More
Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade 240 sq.mm. (Three Core).

30

-

-

... More
S/E of Heat shrinkable cable end termination for 11 KV/6.6

-

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Outdoor Type).

3

-

-

... More
Supply, Installation, testing and commissioning of 11 KV Double Pole structure with Air Break Switch having following specifications: RUIDP SOR 2017 66.3

1

-

-

... More
DP: Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required.

-

-

-

... More
GO: Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A, 3 phase, central post rotating double break isolator complete with MS hardware, copper moving & fixed contact, assembly of 9 Nos pin insulator, GI pipe of suitable length for operation.

-

-

-

... More
DO: 3 nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6 no pin insulators.

-

-

-

... More
LA: 3 piece non-linear resistor type, lightning arrestor of approved make suitable for 3 wire, 11kv OH line with rated voltage of 9kv rms & nominal discharge current rating of 5 KA & complete with galvanized clamping arrangements GI bolts, nuts, washer etc. as required.

-

-

-

... More
JUMPERS: 3 no 11kv ACSR conductors mounted on pin type insulators as required.

-

-

-

... More
GENERAL: The GO shall be operated by hand operated liver properly earthed with provision for locking mounted at 3'.

-

-

-

... More
Transformers:

-

-

-

... More
Supply, Installation, Testing and Commissioning of copper wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type, Standard accessories like, conservator, Silica gel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain/ Flanged Rollers, Earthing terminal, Air release plug, Off load tap changer (+5% to -10% in steps of 2.5%), winding / Top oil temperature rise of 45 deg C/40 deg C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc. having max. total losses as per energy efficiency level-2 at basic insulation level conforming to Is 2025 (Part-I to Part-II), latest amended and IS 1180 Part-I: 2014 BEE star level - 1 as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating:

-

-

-

... More
RUIDP SOR 2017 66.10.2.5

-

-

-

... More
160 KVA

1

-

-

... More
Providing, fixing & erection of Transformer foundation including 6SWG wire mesh fencing all around the transformer with post, frame, gate & their foundation, structure and other civil related work complete as required (item to be executed as per CSR/DSR/RUIDP/SOR).

1

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self-regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.10

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
125 KVA at 0.8 of 415V 50Hz 3-phase

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.2

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
80 to 180 KVA

1

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 315 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 315 A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 30 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus., complete as required - 3 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set.

-

-

-

... More
d) 35 KVAR (5x6+1x5) heavy duty MD Capacitor bank with 8 step APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 10sq.mm (Twin Core)

100

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 120sq.mm (3 ½ Core)

50

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

100

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 6sq.mm (4 Core)

45

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 25sq.mm (3 Core)

90

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

8

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 6 sq. mm

4

-

-

... More
Gland for Aluminium cable 4 core size 10 sq. mm

8

-

-

... More
Gland for Aluminium cable 3.5, 4 core size 25-35 sq. mm

6

-

-

... More
Gland for Aluminium cable 3½ core size 95-120 sq. mm

2

-

-

... More
Gland for Aluminium cable 3½ core size 300 sq. mm

2

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

40

-

-

... More
Aluminium cable core size 10 sq.mm. - 16 sq. mm

16

-

-

... More
Aluminium cable core size 25 sqmm-35 sq. mm.

18

-

-

... More
Aluminium cable core size 120 sq. mm.

8

-

-

... More
Aluminium cable core size 300 sq. mm.

8

-

-

... More
Supply and erection of MS perforated cable tray with DA grey paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fasteners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications 2010.

-

-

-

... More
MS perforated cable tray size 150mm x 50mm x 50mm (2mm thick)

40

-

-

... More
MS perforated cable tray size 50mm x 50mm x 50mm (2mm thick) L Type

50

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

12

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

80

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

150

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

150

-

-

... More
Wiring, Lighting & Accessories:

-

-

-

... More
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES :

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked, recessed in wall etc. Complete with powder coated/anodised concealed metal boxes required for having electronic fan regulators ( socket size), bell push, electronic buzzer, 3 pin 6 Amp., 3 pin 16/20 Amp. Sockets and 6 Amp/16/20 Amp. Switches (flush piano type accessories) etc. and covered with brown bakelite white glazed translucent backside painted sheet 3 mm.thick etc. & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (for Fan Box and Electronic Buzzer), PVC Bush, Steel hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and. filling up of chases.:

-

-

-

... More
Wiring fan point with sheet metal fan box ( shape hexagonal ) in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade with step type electronic fan regulator 100 watts ( socket size)

6

-

-

... More
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 Sqm. 1100 volts grade.

12

-

-

... More
Wiring 3 pin 6 Amp. Wall socket point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sq.mm., 1100 volts grade.

6

-

-

... More
Wiring 3 pin 16/20 amp. Power plug control and switch.

6

-

-

... More
Supply and errection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and errection of pipe or casing.

-

-

-

... More
PVC insulated copper conductor single core FR cable (ISI marked) overall 2.5 sq.mm.1100 volts grade.

200

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/TPN MCB's/isolators for incoming and DP/SP & N/Single Pole MCB's/CBO/RCCB's for outgoing 6 way each

1

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

1

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker four pole 6 to 32 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply.

1

-

-

... More
Miniature circuit breaker double pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply.

2

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

12

-

-

... More
Providing and fixing of LED indoor light fixture 18 W as per RUIDP SOR code no. 57.26.3 complete as required at site.

10

-

-

... More
RUIDP SOR 2017 57.26.3

-

-

-

... More
Providing and fixing LED Street light fixture 30-40 Watt (as per RUIDP SOR code no. 58.31.1.2) on single arm bracket (as per CSR code no. 33.31 A (i) for exterior illumination of Pump House complete as required at site.

2

-

-

... More
Providing and erection of 3-stepped steel tubular swaged and welded pole 7 metre length (as per CSR code no. 33.31 A(i)) with single arm bracket (as per CSR code no. 33.29 B (i)) & LED Street light fixture 60 watt (as per RUIDP SOR code no. 58.31.1.4) complete with required civil work etc. & as required at site.

4

-

-

... More
Providing and fixing of heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust Fan including making connections testing etc. as required.

-

-

-

... More
SOR RUIDP 2017, 55.9.3

-

-

-

... More
450 mm Sweep (900 RPM)

4

-

-

... More
P&F of capacitor start, three speed wall mounting/ cabin fan of following sweep with the help of anchor bolts including making connection testing etc. as required.

-

-

-

... More
SOR RUIDP 2017, 55.12.1

-

-

-

... More
400 mm sweep (oscillating type)

2

-

-

... More
Safety items for Electrical Room/ Pump House:

-

-

-

... More
Providing & fixing of shock treatment chart on wooden frame with 5 mm thick glass (Approx. Front Area 1.20 Sqm) Nabhi's NS Rates Electrical 2014, page 56

1

-

-

... More
Providing & fixing with bracket/supports etc. wall mounted Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5 Kg capacity.

1

-

-

... More
RUIDP SOR 2017 67.39.4

-

-

-

... More
Providing & fixing of First Aid Box Confirming to IS: 2217 - 1963. Nabhi's NS Rates Electrical 2014, Page 56

1

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969. Nabhi's NS Rates Electrical 2014, Page 56

4

-

-

... More
Providing of insulating hand gloves as Per Relevant IS Code

1

-

-

... More
Providing & fixing of self-contained type LED emergency light with 2 Hrs. backup.

3

-

-

... More
Sector- 70

-

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 100 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 63A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Automatic Star-Delta Starter for 11 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set.

-

-

-

... More
d) 5 KVAR heavy duty MD Capacitor with MCB, capacitor duty contactor, necessary protection complete as required - 2 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self-regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.2

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
30 KVA at 0.8 of 415V 50Hz 3-phase

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.1

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
25 to 63.5 KVA

1

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

6

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

20

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

20

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

20

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 25sq.mm (3 ½ Core)

50

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

6

-

-

... More
Gland for Aluminium cable 3½, 4 core size 25-35 sq. mm

2

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

18

-

-

... More
Aluminium cable core size 25 sq. mm. - 35 sq. mm.

8

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969. Nabhi's NS Rates Electrical 2014, Page 56

2

-

-

... More
Phase- 9

-

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 400 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 400A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 55 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus., complete as required - 3 Set

-

-

-

... More
b) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
c) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set.

-

-

-

... More
d) 53 KVAR (10x3+5x3+2x3+1x2) heavy duty MD Capacitor bank with APFC relay, MCCB, capacitor duty contactor, necessary protection complete as required - 1 set

-

-

-

... More
e) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self-regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.11

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
140 KVA at 0.8 of 415V 50Hz 3-phase

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.2

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
80 to 180 KVA

1

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

6

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

30

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

60

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

50

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 120sq.mm (3 ½ Core)

50

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

6

-

-

... More
Gland for Aluminium cable 3½ core size 95-120 sq. mm

2

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

18

-

-

... More
Aluminium cable core size 120 sq. mm.

8

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969. Nabhi's NS Rates Electrical 2014, Page 56

3

-

-

... More
Phase -10

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES:

-

-

-

... More
Supply & laying of Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC inner sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size:-

-

-

-

... More
Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1 sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(UE) grade 240 sq.mm. (Three Core).

25

-

-

... More
S/E of Heat shrinkable cable end termination for 11 KV/6.6

-

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Indoor Type).

2

-

-

... More
Heat Shrinkable for cable size 240-300 sq.mm (Outdoor Type).

1

-

-

... More
11 kV HT Panel (draw out type):

-

-

-

... More
Supply, Installation, Testing and Commissioning of indoor type floor mounted metal clad, 11 KV Incomer cum outgoing VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25kA/3 and IAC A-FLR for 25kA/1 sec. Make of HT Panel, Vacuum Interrupter and VCB should be of same make. 11 KV/110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering up to 12 KV on incomer, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core ration 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class - 0.5 for metering and class 5P10 for protection, Multifunction Meter.

1

-

-

... More
RUIDP SOR 2017 66.12.1

-

-

-

... More
Transformers:

-

-

-

... More
Supply, Installation, Testing and Commissioning of copper wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type, Standard accessories like, conservator, Silica gel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain/ Flanged Rollers, Earthing terminal, Air release plug, Off load tap changer (+5% to -10% in steps of 2.5%), winding / Top oil temperature rise of 45 deg C/40 deg C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc. having max. total losses as per energy efficiency level-2 at basic insulation level conforming to Is 2025 (Part-I to Part-II), latest amended and IS 1180 Part-I: 2014 BEE star level - 1 as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating:

-

-

-

... More
RUIDP SOR 2017 66.10.2.8

-

-

-

... More
315 KVA

1

-

-

... More
O.L.T.C. with R.T.C.C. & AVR (for 11KV). RUIDP SOR 2017 66.10.4.5

1

-

-

... More
SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self-regulated with standard Alternator Protection (Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping, electronic / Mechanical governor, Manual & electric start, Batteries, Fuel tank (with stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weather-proof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183. The doors are fabricated from 1.6 mm CRCA sheet packed with acoustic material, floor of MS chequered plate 5.0 mm thick, all doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 deg C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system MCCB, Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. lamps etc. mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 dB (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity:

-

-

-

... More
RUIDP 2017 66.18.2.16

-

-

-

... More
Radiator cooled and turbo charged:

-

-

-

... More
250 KVA at 0.8 of 415V 50Hz 3-phase

1

-

-

... More
SITC of AUTO MAINS FAILURE (AMF) Panel fabricated from CRCA sheet steel 2mm Thick, Powder coated finish, Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter, Control & Power Contactors, Timers, Electronic Hooter, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:

-

-

-

... More
RUIDP 2017 66.19.2.3

-

-

-

... More
Electro-Mechanical Relay Based:

-

-

-

... More
200 to 500 KVA

1

-

-

... More
ACB Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 800 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer cum Outgoing:

-

-

-

... More
415 V 800A TPN ACB EDO with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 1 Set

-

-

-

... More
LT Panel:

1

-

-

... More
LT Panel 415 V indoor IP-42, compartmentalized, floor mounted, 1.6 mm CRCA sheet for non-load bearing/ 2 mm for load bearing member, front lockable hinged door, dust & vermin proof, epoxy coated, detachable gland plate, 630 A TPN Al. bus-bar complete with all required accessories and interlocks and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V TPN 630A MCCB with O/L, S/C & E/F protection, microprocessor based trip unit, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 2 Set with Electrical & Mechanical interlock.

-

-

-

... More
Outgoing:

-

-

-

... More
a) Digital Soft Starter 55 KW with incomer MCCB and conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus., complete as required - 4 Set

-

-

-

... More
b) Automatic Star-Delta Starter for 7.5 KW with MCB, Main & Aux. contactor, O/L relay, L/R selector switch, 3 indicating lamps, start-stop push button, control MCB, digital multifunction meter complete with all accessories as required - 2 Set.

-

-

-

... More
c) 32A TPN MCCB 25 KA with O/L, S/C protection, indication lamps for On-Off-Trip, R-Y-B - 4 set

-

-

-

... More
d) 32A TP MCB for Actuators with indication lamps for On-Off-Trip, R-Y-B - 3 set

-

-

-

... More
e) 65 KVAR (15x4+1x5) heavy duty MD Capacitor bank with APFC relay, MCCB, contactor, necessary protection complete as required - 1 set

-

-

-

... More
f) Panel shall be SCADA compatible with sufficient interposing relays, auxiliary contactors, potential free contacts etc. as per automation philosophy and as required.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated PVC sheathed armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 10sq.mm (Twin Core)

200

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (Three Core)

150

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

250

-

-

... More
XLPE INSULATED ARMOURED CABLES (LOOSE):

-

-

-

... More
Supply & laying of aluminium conductor XLPE insulated armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 70sq.mm (Three Core)

110

-

-

... More
Aluminium conductor XLPE/ PVC insulated PVC sheathed armoured and served cable working voltage 1100volts grade 300sq.mm (3 ½ Core)

150

-

-

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply and laying of XLPE insulated P.V.C. sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 4sq.mm (3 Core)

50

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 1100volts grade 6sq.mm (4 Core)

25

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 4 sq. mm

16

-

-

... More
Gland for Aluminium cable 2, 3, 4 core size 6 sq. mm

2

-

-

... More
Gland for Aluminium cable 4 core size 10 sq. mm

10

-

-

... More
Gland for Aluminium cable 3.5, 4 core size 70 sq. mm

4

-

-

... More
Gland for Aluminium cable 3½ core size 300 sq. mm

12

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq.mm. - 6 sq. mm

42

-

-

... More
Aluminium cable core size 10 sq.mm. - 16 sq. mm

20

-

-

... More
Aluminium cable core size 70 sq. mm.

12

-

-

... More
Aluminium cable core size 300 sq. mm.

48

-

-

... More
Supply and erection of MS perforated cable tray with DA grey paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fasteners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications 2010.

-

-

-

... More
MS perforated cable tray size 150mm x 50mm x 50mm (2mm thick)

50

-

-

... More
MS perforated cable tray size 300mm x 50mm x 50mm (2mm thick)

75

-

-

... More
MS perforated cable tray size 50mm x 50mm x 50mm (2mm thick) L Type

75

-

-

... More
Providing and erection of 3-stepped steel tubular swaged and welded pole 7 metre length (as per CSR code no. 33.31 A(i)) with single arm bracket (as per CSR code no. 33.29 B (i)) & LED Street light fixture 60 watt (as per RUIDP SOR code no. 58.31.1.4) complete with required civil work etc. & as required at site.

10

-

-

... More
GI Earthing including GI Strip & G.I wires:

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-

-

-

-

... More
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling).

14

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR (E&M) 2016, 5.11

100

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required. DSR (E&M) 2016, 5.15

200

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR (E&M) 2016, 5.16

200

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969Nabhi's NS Rates Electrical 2014, Page 56

10

-

-

... More
Instrumentation, PLC and SCADA

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
WTP, Sector 56

-

-

-

... More
Inlet:

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC OPEN CHANNEL FLOW METER (up to 5 metre Head rise) for water Application: Principle: Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy +/- 1%.

1

-

-

... More
RUIDP SOR 2017 68.17

-

-

-

... More
Providing, Installation, Testing and Commissioning of TURBIDITY ANALYSER for Water Application: Turbidity Measuring range: 0 to 100 NTU; Accuracy: +/-2% of reading or +/-0.02NTU; Compliance to US EPA180.1, With inbuilt transmitter with 4-20 mA output, Relay contacts & Modbus communication.

-

-

-

... More
RUIDP SOR 2017 68.24.1

-

-

-

... More
0 - 100 NTU

2

-

-

... More
Providing, Installation, Testing and Commissioning of PH ANALYSER for Water Application : Transmitter : Range: 0-14 pH, Power Supply 230 VAC, Input: One Digital Sensor, Output: 4-20mA HART, IP66 Protection / Tx protection cover required / Sensor Range 0-14 pH, able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter, process temp: 65 deg cen/flow through tee MOC SS.

-

-

-

... More
RUIDP SOR 2017 68.22.1

-

-

-

... More
0-14 PH

2

-

-

... More
Filter House:

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18

-

-

-

... More
0-5 MTR.

3

-

-

... More
Providing, Installation, Testing and Commissioning of Rate of Flow Indicator in Inlet and Outlet Filter House: Measuring Range: 0-6 metre/Field mounted Transmitter with LCD Display/Power Supply: 230V DC/Output: 4-20 mA with HART/IP66/Sensor 0-6 metre/Principal Time of Flight/Housing PVDF/IP68 Protection.

-

-

-

... More
RUIDP SOR 2017 68.27.1

-

-

-

... More
0-6 metre

3

-

-

... More
Providing, Installation, Testing and Commissioning of Loss of Head Indicator in Filter Beds: Measuring Range: 0-3 metre/Field mounted Transmitter with LCD Display/Power Supply: 230V DC/Output: 4-20 mA with HART/IP66/Sensor 0-3 metre/Principal Time of Flight/Housing PVDF/IP68 Protection.

-

-

-

... More
RUIDP SOR 2017 68.26

-

-

-

... More
0-3 metre. RUIDP SOR 2017 68.26.1

3

-

-

... More
Filter bed Air Agitation system (at Blower Discharge):

-

-

-

... More
Providing, installation, testing and commissioning of Glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer:

-

-

-

... More
RUIDP SOR 2017 19.52.2

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2

2

-

-

... More
Bimetallic Temperature Gauge at Blower discharge; Dial size: 100, Casing & Bezel material: SS304, Stem material: SS316, Stem Dia: 6/8/10/12 mm, stem Length: 100 mm to 600 mm, Mounting: Bottom/Back entry, Process Connection: 1/2 inch BSP / NPT (M), window material: Toughened / Shatterproof Glass, Enclosure: IP 65, over range Protection: 130% FSD, Accuracy: cl. 2 as per EN 13190.

2

-

-

... More
Clear Water Channel:

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC OPEN CHANNEL FLOW METER (up to 5 metre Head rise) for water Application: Principle: Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy +/- 1%.

1

-

-

... More
RUIDP SOR 2017 68.17

-

-

-

... More
Clear Water Reservoir:

-

-

-

... More
Providing, Installation, Testing and Commissioning of CHLORINE ANALYSER for Water Application: Transmitter ; Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH, able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range: 0.05 to 20 mg/l

-

-

-

... More
RUIDP SOR 2017 68.23.1

-

-

-

... More
0.05 - 20 mg/l

1

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

3

-

-

... More
PLC for 5 MGD WTP + Pump House complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 5 KVA online UPS with 1 hour backup, 2 No's PC with console, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
PUMP HOUSE WTP 56

-

-

-

... More
Pressure Gauge for each Pump and in Common Header:

-

-

-

... More
Providing, installation, testing and commissioning of glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer:

-

-

-

... More
RUIDP SOR 2017, 19.52.2

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2

6

-

-

... More
Level Transmitter in Sump:

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

1

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017 , 68.16.13

-

-

-

... More
600 MM

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6

-

-

-

... More
(RUIDP SOR 2017 19.22.3)

-

-

-

... More
200 mm. (RUIDP SOR 2017 19.22.3.5)

4

-

-

... More
250 mm. (RUIDP SOR 2017 19.22.3.6)

1

-

-

... More
PLC complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 5 KVA online UPS with 1 hour backup, 2 No's PC with console, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required (Price included in Combined PLC with WTP-56)

-

-

-

... More
Phase- 1 & 6

-

-

-

... More
Providing, installation, testing and commissioning of glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer: RUIDP SOR 2017 19.52.2

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2

3

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable: 10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display: 3 1/2 LCD Display/ Cable connection: 1/2" NPT/Accuracy: 0.5%.

-

-

-

... More
RUIDP SOR 2017, 68.16.7

-

-

-

... More
250 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6

-

-

-

... More
(RUIDP SOR 2017 19.22.3)

-

-

-

... More
250 mm dia (at inlet of UGSR) (RUIDP SOR 2017 19.22.3.6)

1

-

-

... More
300 mm dia (at inlet of OHSR & By-Pass) (RUIDP SOR 2017 19.22.3.7)

2

-

-

... More
PLC/RTU for 1 No. UGSR + 1 No. OHSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
Phase- 3, 4, 5

-

-

-

... More
Providing, installation, testing and commissioning of glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer:

-

-

-

... More
RUIDP SOR 201719.52.2

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2

3

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017 68.16.8

-

-

-

... More
300 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6 (RUIDP SOR 2017 19.22.3.7)

-

-

-

... More
300 mm dia (at inlet of UGSR & OHSR, Bypass)

4

-

-

... More
PLC/RTU for 1 No. UGSR + 1 No. OHSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
Phase- 2

-

-

-

... More
Providing, installation, testing and commissioning of glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer: RUIDP SOR 201719.52.2

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2.

3

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017 68.16.7

-

-

-

... More
250 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6

-

-

-

... More
(RUIDP SOR 2017 19.22.3)

-

-

-

... More
250 mm dia (at inlet of UGSR) (RUIDP SOR 2017 19.22.3.6)

1

-

-

... More
300 mm dia (at inlet of OHSR & Bypass) (RUIDP SOR 2017 19.22.3.7)

2

-

-

... More
PLC/RTU for 1 No. UGSR + 1 No. OHSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
Phase- 7

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017, 68.16.8

-

-

-

... More
300 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6 (RUIDP SOR 2017 19.22.3.7)

-

-

-

... More
300 mm dia (at inlet of UGSR & OHSR, Bypass)

3

-

-

... More
PLC/RTU for 1 No. UGSR + 1 No. OHSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
WTP, Sector- 57

-

-

-

... More
Inlet:

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC OPEN CHANNEL FLOW METER (up to 5 metre Head rise) for water Application: Principle: Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy +/- 1%.

1

-

-

... More
RUIDP SOR 2017 68.17

-

-

-

... More
Providing, Installation, Testing and Commissioning of TURBIDITY ANALYSER for Water Application: Turbidity Measuring range: 0 to 100 NTU; Accuracy: +/-2% of reading or +/-0.02NTU; Compliance to US EPA180.1, With inbuilt transmitter with 4-20 mA output, Relay contacts & Modbus communication.

-

-

-

... More
RUIDP SOR 2017 68.24.1

-

-

-

... More
0 - 100 NTU

2

-

-

... More
Providing, Installation, Testing and Commissioning of PH ANALYSER for Water Application : Transmitter : Range: 0-14 pH, Power Supply 230 VAC, Input: One Digital Sensor, Output: 4-20mA HART, IP66 Protection / Tx protection cover required / Sensor Range 0-14 pH, able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter, process temp: 65 deg cen/flow through tee MOC SS.

-

-

-

... More
RUIDP SOR 2017 68.22.1

-

-

-

... More
0-14 pH

2

-

-

... More
Filter House:

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

3

-

-

... More
Providing, Installation, Testing and Commissioning of Rate of Flow Indicator in Inlet and Outlet Filter House: Measuring Range: 0-6 metre/Field mounted Transmitter with LCD Display/Power Supply: 230V DC/Output: 4-20 mA with HART/IP66/Sensor 0-6 metre/Principal Time of Flight/Housing PVDF/IP68 Protection.

-

-

-

... More
RUIDP SOR 2017 68.27.1

-

-

-

... More
0-6 metre

3

-

-

... More
Providing, Installation, Testing and Commissioning of Loss of Head Indicator in Filter Beds: Measuring Range: 0-3 metre/Field mounted Transmitter with LCD Display/Power Supply: 230V DC/Output: 4-20 mA with HART/IP66/Sensor 0-3 metre/Principal Time of Flight/Housing PVDF/IP68 Protection.

-

-

-

... More
RUIDP SOR 2017 68.26.1

-

-

-

... More
0-3 metre

3

-

-

... More
Filter bed Air Agitation system (at Blower Discharge):

-

-

-

... More
Providing, Installation, Testing and Commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows/Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminium, Switch type: Micro switch, Repeatability: =/- of span, Switch Contacts: 2 NO+2NC.

2

-

-

... More
RUIDP SOR 2017 68.11

-

-

-

... More
Providing, installation, testing and commissioning of glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer:

-

-

-

... More
RUIDP SOR 2017 19.52.2

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2

2

-

-

... More
Bimetallic Temperature Gauge at Blower discharge; Dial size: 100, Casing & Bezel material: SS304, Stem material: SS316, Stem Dia: 6/8/10/12 mm, stem Length: 100 mm to 600 mm, Mounting: Bottom/Back entry, Process Connection: 1/2 inch BSP / NPT (M), window material: Toughened / Shatterproof Glass, Enclosure: IP 65, over range Protection: 130% FSD, Accuracy: cl. 2 as per EN 13190.

2

-

-

... More
Clear water channel:

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC OPEN CHANNEL FLOW METER (up to 5 metre Head rise) for water Application: Principle: Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy +/- 1%.

1

-

-

... More
RUIDP SOR 2017 68.17

-

-

-

... More
Clear Water Reservoir:

-

-

-

... More
Providing, Installation, Testing and Commissioning of CHLORINE ANALYSER for Water Application: Transmitter ; Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH, able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range: 0.05 to 20 mg/l

-

-

-

... More
RUIDP SOR 2017 68.23.1

-

-

-

... More
0.05 - 20 mg/l1

1

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

3

-

-

... More
PLC for 5 MGD WTP + Pump House complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 5 KVA online UPS with 1 hour backup, 2 No's PC with console, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
Pump House, WTP Sector- 57

-

-

-

... More
Pressure Gauge for each Pump and in Common Header:

-

-

-

... More
Providing, installation, testing and commissioning of glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer:

-

-

-

... More
RUIDP SOR 2017 19.52.2

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2

8

-

-

... More
Level Transmitter in Sump:

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

1

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017 68.16.13

-

-

-

... More
600 MM

2

-

-

... More
PLC complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 5 KVA online UPS with 1 hour backup, 2 No's PC with console, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required. (Price included in combined PLC with WTP-57)

-

-

-

... More
SECTOR 72&73

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017 68.16.7

-

-

-

... More
250 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6

-

-

-

... More
(RUIDP SOR 2017 19.22.3)

-

-

-

... More
150 mm dia (at inlet of UGSR)

1

-

-

... More
(RUIDP SOR 2017 19.22.3.4)

-

-

-

... More
300 mm dia (at inlet of OHSR & Bypass).

2

-

-

... More
(RUIDP SOR 2017 19.22.3.7)

-

-

-

... More
PLC/RTU for 1 No. UGSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
Sector- 71

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017 68.16.10

-

-

-

... More
400 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6.

-

-

-

... More
(RUIDP SOR 2017 19.22.3)

-

-

-

... More
300 mm dia (at inlet of UGSR)

1

-

-

... More
(RUIDP SOR 2017 19.22.3.5)

-

-

-

... More
400 mm dia (at inlet of OHSR & Bypass)

2

-

-

... More
(RUIDP SOR 2017 19.22.3.9)

-

-

-

... More
PLC/RTU for 1 No. UGSR + 1 No. OHSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
MATTOUR

-

-

-

... More
Providing, installation, testing and commissioning of glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer: RUIDP SOR 2017, 19.52.2

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2

3

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017, 68.16.8

-

-

-

... More
300 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6,

-

-

-

... More
(RUIDP SOR 2017 19.22.3)

-

-

-

... More
300 mm dia (at inlet of OHSR & Bypass) (RUIDP SOR 2017 19.22.3.7)

2

-

-

... More
400 mm dia (at inlet of UGSR) (RUIDP SOR 2017 19.22.3.10)

1

-

-

... More
PLC/RTU for 1 No. UGSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
SECTOR 70

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.

-

-

-

... More
RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017, 68.16.5

-

-

-

... More
150 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6,

-

-

-

... More
(RUIDP SOR 2017 19.22.3)

-

-

-

... More
150 mm dia (at inlet of UGSR) (RUIDP SOR 2017 19.22.3.4)

1

-

-

... More
300 mm dia (at inlet of OHSR & Bypass) (RUIDP SOR 2017 19.22.3.7)

2

-

-

... More
PLC/RTU for 1 No. UGSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
Phase 9

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017 68.16.8

-

-

-

... More
300 MM (at common header of UGSR)

1

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. (RUIDP SOR 2017 19.22)

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6, (RUIDP SOR 2017 19.22.3)

-

-

-

... More
300 mm dia (at inlet of UGSR & OHSR, Bypass)

3

-

-

... More
(RUIDP SOR 2017 19.22.3.7)

-

-

-

... More
PLC/RTU for 1 No. UGSR + 1 No. OHSR complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
Phase 10

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application: Principal: Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66.RUIDP SOR 2017 68.18.1

-

-

-

... More
0-5 MTR

2

-

-

... More
Providing, Installation, Testing and Commissioning of Magnetic Flow Meter for water application: Liner: Polyurethane or Hard Rubber/Electrode MOC: SS316L or CS/Housing: Die Cast Aluminium or CS/Power Supply: 90-230 V AC/Output: 4-20mA with HART/Sensor Cable:10 mt/Flow Tube or Sensor housing protection IP68/Process Flange: SS316/Display:3 1/2 LCD Display/ Cable connection:1/2" NPT/Accuracy: 0.5%

-

-

-

... More
RUIDP SOR 2017 68.16.13

-

-

-

... More
600 MM

2

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make and design standard of the following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.

-

-

-

... More
RUIDP SOR 2017 19.22

-

-

-

... More
Electrically Operated & SCADA Compatible class PN 1.6, (RUIDP SOR 2017 19.22.3)

-

-

-

... More
150 mm

1

-

-

... More
(RUIDP SOR 2017 19.22.3.4)

-

-

-

... More
300 mm,

1

-

-

... More
(RUIDP SOR 2017 19.22.3.7)

-

-

-

... More
350 mm,

1

-

-

... More
(RUIDP SOR 2017 19.22.3.8)

-

-

-

... More
600 mm,

1

-

-

... More
(RUIDP SOR 2017 19.22.3.12)

-

-

-

... More
PLC/RTU for Booster Pumping Station (Phase-10) complete with the following: Controller, required DI/DO/AI/AO card, power module, fully wired Panel for mounting above accessories with indicator, panel mounted HMI, RS 485 to Ethernet TCP/IP Gateway, Ethernet Switch, Hardware firewall, GSM/GPRS Modem, Alarm Annunciator, required Programming & Troubleshooting Software, 1 KVA online UPS with 1 hour backup, data card with connection, required cables, JBs, ICP/instruments, earthing, tray/conduit/support complete with all accessories/item as required.

1

-

-

... More
Instrument & Data loggers for field measurement

-

-

-

... More
Providing, Installation, Testing and Commissioning of ULTRASONIC FLOW METER CLAMP ON TYPE for water application: Principle: Time of Flight / Type: Clamp on / Protection : IP68 / Power Supply: 230 V AC (with provision of battery operation) / Output : 4-20 mA with HART / Accuracy: 2-3%

-

-

-

... More
RUIDP SOR 2017 68.19.1

-

-

-

... More
100-2000 DN

1

-

-

... More
Providing, Installation, Testing and Commissioning of Battery Powered Telemetry Data Logger for monitoring of flow & pressure with in-built pressure transducer 10 bar, one bi-directional flow measurement pulse/4-20 mA (from above Ultrasonic Flow Meter) with external aerial, including Modbus for third party devices, internal cellular Modem, memory of 500000 readings, multiple alarm options, fast logging, fully sealed & submersible IP-68, long battery life, operating Temp.: -20 to 70 deg C, flow meter cable, 1 m pressure hose, quick fit connector, data card etc. ready for direct communication with SCADA complete as required.

2

-

-

... More
PC Communication Cable lead with USB connector for logger configuration, software license for integration of Data Loggers with external server (SCADA) complete as required.

1

-

-

-

-

-

... More
SCADA for 24x7 Operation, Control and Monitoring of (2 No's WTP with Pump House, 10 No's Pumping Station, 10 No's OHSR, 2 No's Field Data Loggers) as per Operation Philosophy complete with all necessary Hardware and Software including but not limited to the following:

1

-

-

... More
Hardware -

-

-

-

... More
1. PLC complete with all Accessories & Panel (1 Set)

-

-

-

... More
2. 16/24-Port Ethernet Switch (1 No.)

-

-

-

... More
3. GPRS Modem (1 No.)

-

-

-

... More
4. Ethernet Cable (as required)

-

-

-

... More
5. Alarm Annunciator (1 No.)

-

-

-

... More
6. USB Key for SCADA

-

-

-

... More
7. 1 No. Laptop loaded with PLC Programming Software Package

-

-

-

... More
8. Hardware Firewall

-

-

-

... More
9. Server Grade PC with 21" Monitor (1 No.)

-

-

-

... More
10. Client PC with 21" Monitor (1 No.)

-

-

-

... More
11. Large Display LED 60" (1 No.)

-

-

-

... More
12. Printer A3/A4- Colour Laser (1 No.)

-

-

-

... More
13. 5 KVA Online UPS with 60 min Battery

-

-

-

... More
14. Data Card with connection

-

-

-

... More
15. Other Items (Console for 2 No's PC & 1 No. Printer with Chair, JB, cables, earthing, tray/conduit/support etc. complete as required). Software -

-

-

-

... More
1. HMI Software for Client

-

-

-

... More
2. Server Software

-

-

-

... More
3. Web Server & Web Client License for Remote Monitoring

-

-

-

... More
4. Software for Engineering, SQL, Software development at site.

-

-

-

... More
5 Years O&M for Electrical, Instrumentation & SCADA System;

-

-

-

... More
1st Year

12

-

-

... More
2nd Year

12

-

-

... More
3rd Year

12

-

-

... More
4th Year

12

-

-

... More
5th Year

12

-

-

... More
Total : (Rs) Complete (Civil + Mechanical +Electriclal) Word to XL Checked

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.