If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 1,81,200Document Cost
₹ 1,000Tender Fee
₹ 5,900
Summary
Aug. Ws Scheme Ghabdan Block And Distt Sangrur
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_WSS_69177_1Bid Award Id
ViewTender No
WSSD/2021-22/59Tender Authority
Water Supply And Sanitation Department ViewPurchaser Address
-Website
http://https://dwss.punjab.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
200 mm i/d
1
-
-
Repair of CI/DI expansion joint complete in all aspects
-
-
-
150 mm I/d
1
-
-
200 mm i/d
2
-
-
Repair of staircase & Painting of Railing including cost of labour and meterial complete in all respect.
1
-
-
Plugging all leakages existing RCC OHSR including necessary material e.g. cement, sand with pressure gun, cleaning of existing RCC OHSR complete in all aspects
1
-
-
P/f aluminium ladder inside tank shall be 60 cm wide madew of alluminum section inside OHSR incl. taxes and carriage etc
1
-
-
P/f MS ladder outside tank shall be 4 mtr long madew of steel section outside OHSR incl. taxes and carriage etc
1
-
-
Jalli including cost of labour and meterial complete in all respect.
1
-
-
CI cover for OHSR including cost of labour and meterial complete in all respect.
1
-
-
Painting of OHSR pipes including cost of labour and meterial complete in all respect.
4
-
-
REPAIR OF PUMP CHAMBER (4.26×4.87M)
-
-
-
Conglomerate floor 50mm thick cement concrete
topping 1:2:4 using mechanical mixer for mixing
of material
21.58
-
-
12.5mm thick cement plaster 1:4
46.37
-
-
Plastering on underside of ceiling 10mm thick cement plaster 1:3
15.91
-
-
Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. i) 40mm thick Door
6.24
-
-
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
18.73
-
-
White washing 3 coats inside of pump chamber
66.65
-
-
Finishing wall with exterior decorative cement based paint such as snowcem robbiacem etc. on new work in two coats to give even shade. Quanity as per Sr. No. 17 Marked “C”
54.48
-
-
Providing and fixing of Glass strips 4mm thick in floors
-
-
-
50mm wide
27
-
-
40mm wide
22
-
-
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of Paris and chalk mitti including finishing the surface to the required finish complete. Inside pump Chamber. Quantity as per Sr No.17 marked (A)
58.54
-
-
Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade. Qty as per sr No.36
58.54
-
-
Supplying & fixing glass panes including special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
6.9
-
-
Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent
1
-
-
Providing and fixing of electric tube set of reputed make
1
-
-
Construction of toilet outside pump chamber complete in all respect
1
-
-
DISINFECTION UNIT
-
-
-
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering Syatem, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressurSe upto 7 kg.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications.
1
-
-
PIPELINE FOR DISTRIBUTION MAIN
-
-
-
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for less than 3 mtr street width. included excavation.
-
-
-
PVC pipe 63mm o/d 6Kg/sqcm
361.04
-
-
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for more than 3 mtr street width.included excavation.
-
-
-
PVC pipe 63mm o/d 6Kg/sqcm
12526.19
-
-
PVC pipe 63mm o/d 6Kg/sqcm (Extra Crossing PVC pipe for connecting to G.I pipe above G.L other side)
168
-
-
PVC pipe 90mm o/d 6Kg/sqcm
3539.61
-
-
PVC pipe 110mm o/d 6Kg/sqcm
332.43
-
-
PVC pipe 160mm o/d 6Kg/sqcm
330.92
-
-
PVC pipe 200mm o/d 6Kg/sqcm
605.89
-
-
Providing, Laying, jointing & fixing testing ISI marked G.I Pipe (as per IS 1239) B- Class, Premium make such as (Jindal Hisar) including cost of Specials (such as tees, Bends, sockets elbows etc.), painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. (For above G.L connection to outside firni)
-
-
-
G.I pipe 25mm i/d
71.13
-
-
G.I pipe 20mm i/d
1642.07
-
-
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
-
-
-
63 mm o/d
4671.63
-
-
90mm o/d
874.73
-
-
Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects.
-
-
-
PVC pipe 63mm o/d
472.84
-
-
PVC pipe 90mm o/d
177.4
-
-
PVC pipe 110mm o/d
43.69
-
-
Dismanntling of Flexible pavements (Bituminous Courses ( By Manual Means)
-
-
-
Dismantling of Bituminous courses of flexible pavements by manual means and disposal of dismantled materials upto a lead of 1000 meters,stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT & H specifications
-
-
-
PVC pipe 63mm o/d
544.16
-
-
PVC pipe 90mm o/d
1382.4
-
-
PVC pipe 110mm o/d
288.74
-
-
PVC pipe 160mm o/d
119.92
-
-
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
-
-
-
80 mm I/d
7
-
-
100 mm I/d
1
-
-
150 mm I/d
1
-
-
150 mm I/d
1
-
-
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete
30
-
-
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6x0.6 mtr.(including cost of Carriage)
10
-
-
Hand boring horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method including excavation,stringing and jointing of pipe upto 160mm complete.
60
-
-
HOUSE SERVICE CONNECTIONS WITH WATER METER
-
-
-
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15 mm o/d = 2.00 mtr, & G.I pipe (ISI marked B-Class)2.50 mtr. including cost of specials such as tees , bends , sockets , elbow etc. cutting , threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3” i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR, Including cost of dismantling brick paving /CC flooring & relaying the same original condition in complete respect
667
-
-
Providing proposed water connection to house hold up to wall on GI pipe with providing, laying jointing, testing G.I pipe (ISI marked B-Class) including cost of specials such as tees , bends , sockets , elbow etc. ISI marked 15mm i/d GM ferrule as per IS: 2692 and c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR, Including cost of dismantling brick paving /CC flooring & relaying the same original condition in complete respect
111
-
-
Providing, fixing & jointing water meter of approved make as per IS:779/94 including ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778,socket , MS hooks complete in all respect.
778
-
-
DEVELOPMENT OF HEAD WORKS
-
-
-
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8
726
-
-
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8
99
-
-
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-8
30
-
-
Repair of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3
4
-
-
Repair of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 complete in all respects
1
-
-
Providing and laying 50 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in ordinary grey colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge & Plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165mm and top width 115mm fixed in position on earth base including carriage to site of work complete as per technical clause 408 of MORT&H specifications.
55
-
-
Painting MS Sign Board as per standard size of DWSS as per Drawing D-20
1
-
-
Construction of 225mm thick brick masonry toe wall in 1:5 cement sand mortar with depth 0.45 mtr ,C.C. 1:8:16 & 12.5 mm thick cement plaster in 1:4 on both sides and top of toe wall complete in all respects
242
-
-
Extra for Carriage of Fine & Course aggregate i.e Sand & Bajri from query Burj Kotian water works site beyond 5 km
-
-
-
Sand from 0 km to 135 km
8.5
-
-
Bajri from 0 km to 135 km
8.5
-
-
Environment Management
-
-
-
Making lawns including ploughing & dragging with 'Sohaga' breaking of clods, removal of earth rubbish dressing & Supplying doob grass roots and planting at 15 cm. apart supplying and spreading of farm yard manure & loosening
160
-
-
Planting permanent hedge including digging of trenches 60 cm wide and 30cm deep refilling the excavated earth mixed with manure supplied @ of 4.65 cum per 100 m & supplying & planting hedge plants at 30 cm apart.
20
-
-
Supplying and planting permanent trees including digging of pits size 75cm x 75cm x 75cm deep, refilling the excavated earth. With with manure supplied @ 0.113 4 cum each like Neem ,Ashoka ,Dake Arjun Etc.
26
-
-
Planting ground cover plants including digging and refilling of beds with excavated soil and FYM, Fertilizer and insecticides, planting of saplings at 30cm distance from plant to plant and row to row, providing and fixing brick tiles edging.
25
-
-
Planting flower beds including digging and refilling of beds with excavated soil and FYM, fertilizer and insecticides, planting of sapling at 30cm distance from plant to plant and row to row. Around pump chamber OHSR and both side of path.
22
-
-
Provision for One way stand post with Khurra complete in all respects s per standard Drawing .
1
-
-