Water Resources Department Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 7,900Document Cost
₹ 1,000Tender Fee
₹ 590
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WR_127123_1Bid Award Id
ViewTender No
13 dated 12.09.2024Tender Authority
Water Resources Department ViewPurchaser Address
-Website
http://eproc.punjab.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
WHITE WASHING, DISTEMPERING, PAINTING & POLISHING Colour washing (two or more coats)
557.11
-
-
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.
27.85
-
-
Providing & laying integral cement based water proofing treatment including preparation of surface a
80.78
-
-
Corrugated G.I. Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. L
19.51
-
-
Conglomerate floor 50mm thick cement concrete rete 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material
75.1
-
-
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (Without fan box)
4
-
-
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- b) Wiring light point
4
-
-
Wiring 6Amp. Plug control comprising wall socket point
4
-
-
Wiring 16/20Amp. power plug control point
4
-
-
SUPPLY AND ERECTION OF WIRING ACCESSORIES:
Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-6/10amp. One Way Modular Switch (One Module)
5
-
-
16/20amp. One Way Modular Switch with Indicator (One Module)
5
-
-
6amp. 2/3 Universal Modular Shuttered Socket (two Module)
5
-
-
16/20amp. Universal Modular Shuttered Socket (two Module)
5
-
-
Step type Modular Electronic Fan Regulator 100watts (One Module)
5
-
-
Bakelite Batten Holder (Large size)
5
-
-
Supply and erection of Modular Cover Frame (Complete set) on the existing metal box including fixing and connection of existing switches and sockets and other petty material etc:-((a)) Modular Cover Frame One or Two Module
3
-
-
((b)) Modular Cover Frame Three Module
3
-
-
((c)) Modular Cover Frame Four Module
3
-
-
((d)) Modular Cover Frame Six Module
3
-
-
((e)) Modular Cover Frame Eight Module
3
-
-
Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):- (a) Powder Coated Concealed Metal Box with Brass Lugs One/Two Module
3
-
-
(b) Powder Coated Concealed Metal Box with Brass Lugs Three Module
3
-
-
(c) Powder Coated Concealed Metal Box with Brass Lugs four Module
3
-
-
(d) Powder Coated Concealed Metal Box with Brass Lugs Six Module
3
-
-
(e) Powder Coated Concealed Metal Box with Brass Lugs Eight Module
3
-
-
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's : A) MINIATURE CIRCUIT BREAKERS:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: MCB Single Pole 6-32amp. (10kA, Curve-C)
3
-
-
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's : A) MINIATURE CIRCUIT BREAKERS:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs;MCB Four Pole 50, 63amp. (10kA, Curve-C)
3
-
-
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09
metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Horizontal Double Door Distribution Board 4 way each
4
-
-
PVC INSULATED FR COPPER CONDUCTOR CABLES:
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the
Engineer-in-charge:- (i) Overall size 1sq.mm (Un-sheathed)
180
-
-
((ii)) Overall size 1.5sq.mm (Un-sheathed)
90
-
-
((iii)) Overall size 2.5sq.mm (Un-sheathed)
50
-
-
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-((xxii)) Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
50
-
-
PVC, HDPE PIPES & PVC FLEXIBLE PIPES:
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per
PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 20mm dia. (On Surface)
20
-
-
((ii)) Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
20
-
-
DISMANTLING WIRING POINTS & FITTINGS: Dismantling old wiring points including necessary repairs to wall etc:- ((i))point Fan, light or call bell
10
-
-
((ii)) Wall socket, power plug point
10
-
-
Dismantling concrete Lime concrete, cement concrete of 1:6:12 or leaner mix
2.13
-
-
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below.
1
-
-
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled Windows of area 3 sqm and below
2
-
-
BRICK WORK First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
5.31
-
-
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
3.18
-
-
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
19.51
-
-
(18.18) Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
2.54
-
-
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
16.61
-
-
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
7.05
-
-
Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect
3.66
-
-
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 3mm or 8.44 kg per sqm upto 0.4 sqm area
0.56
-
-
Supplying and fixing fan clamps with 50mmx6mm flat iron 50cm long and U-hooks of 16mm diametre M.S. Bars, of approved size with nuts including threading etc. complete in all respects.
1
-
-
PLASTERING & POINTING 12.5 mm thick cement plaster 1:5
51.44
-
-
HOISTING, ROOFING AND WATER PROOFING Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on an
19.51
-
-
Earth filling under floors with surplus soil containing more than 40% gravel or kankar excavated from foundation & taken only from outside the building plinth in 15 cm layers including ramming watering and consolidation lead upto 30 metres
4.08
-
-
FLOORING & DADOS Laying of Dry Brick Ballast 40 mm gauge for flooring.
1.02
-
-
Cutting holes upto 23cm square for pipes in flooring and roofs of bricks, tiles with lime concrete or cement concrete and making good the same & finishing according to existing finish where required Through floor or roof 11.5cm thick
2
-
-
SANITARY INSTALLATIONS Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition Size 75 mm x 75 mm
50
-
-
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position
(Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
2.11
-
-
WHITE WASHING, DISTEMPERING, PAINTING & POLISHING Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
110
-
-
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc
2
-
-
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade
2
-
-
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
110
-
-
HEAVY GAUGE WELDED CONDUIT PIPES:
Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General
Specifications:- Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.
0.46
-
-
ERECTION, REPAIR AND REWINDING OF FANS Erection of Ceiling/ Cabin/ Exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete:-Erection of Ceiling fan
1
-
-
((c)) Erection of Exhaust fan with louver shutter on the wall/ window grill
1
-
-
Erection of light fixtures on wall/ ceiling having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete:- Erection of 1X20/28/36/40W Box Type (LED/ Fluorescent) light fixture
4
-
-
Providing Exhuast Fan 300mm
1
-
-
Providing Ceiling Fan
1
-
-
Providing LED Tube of 30W
4
-
-
Cement concrete 1:2:4 With shingle stone ballast or mixing by manual means
1.36
-
-