Water Resources Department Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Water Resources Department - WRD Tender

Civil And Construction
Irrigation Work
Eprocure
Opening Date3 Jul 2023
Closing Date24 Jul 2023
Tender Amount₹ 4,07,27,517 
Notes
Download

Costs

  • EMD

    ₹ 8,14,550
  • Document Cost

    ₹ 2,000
  • Tender Fee

    ₹ 5,900

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(3) INCOMING SUPPLY FROM TRANSFORMER

-

-

-

... More
(3) 1 No. 1250 A, 3 pole, 50 kA Microprocessor based motorized ACB with O/L, S/C, & E/F protections; 1 No. Ammeter 0-1250A; 1 No. Volt Meter 0-500V; 1 No. Ammeter Selector Switch; 1 No. Voltmeter Selector Switch; 3 Nos. Indication Lamps RYB; 3 Nos. Control MCB 2A; 4 Nos. CT’s 1250/5; 4 Nos. Control Terminals; 1 No. 16 A Neutral Link; 4 Nos. CT Shorting Link, 1 No. Reverse Power Relay, 1 No. Master Trip Relay, 1 No. TCS Relay

-

-

-

... More
(3) INCOMING SUPPLY FROM SOLAR PV PLANT

-

-

-

... More
(3) 1 No. 1250 A, 3 pole, 50 kA Microprocessor based motorized ACB with O/L, S/C, & E/F protections; 1 No. Ammeter 0-1250A; 1 No. Volt Meter 0-500V; 1 No. Ammeter Selector Switch; 1 No. Voltmeter Selector Switch; 3 Nos. Indication Lamps RYB; 3 Nos. Control MCB 2A; 4 Nos. CT’s 1250/5; 4 Nos. Control Terminals; 1 No. 16 A Neutral Link; 4 Nos. CT Shorting Link

-

-

-

... More
(3) OUTGOING FEEDERS

-

-

-

... More
(3) 4 Nos. SOFT STARTERS for Item No. 1: 4 Nos. 250 A, 3 Pole, 50 kA MCCB with adjustable overload protection (70% to 100%) with ROM & spreader, 3 wire suitable for inline connection with LCD display for precise motor start, stop, monitor, control and protection having adjustable settings like initial voltage output between 30-70 % of the nominal voltage, Dual current limit between 200 % and 500 % of the soft starter’s rated full load current with timer, adjustable Ramp in and ramp out time, kick start etc. Soft starter must have integrated motor and load protection features like overload protection with dual overload class settings, high current protection, locked rotor protection, under load protection and torque control feature for precise pump control, 1 No. Aux contractor, 4 Nos. start push button; 4 Nos. stop push button, mushroom head; 12 Nos. indicator lamps on/off/trip; 4 Nos. A/M selector switch; 4 Nos. control MCB 2 A; 12 Nos. control terminals; 24 Nos. power terminals; 4 Nos. neutral link

-

-

-

... More
(3) 4 No. SOFT STARTERS for Item No. 2: 4 No. 250 A, 3 Pole, 50 kA MCCB with adjustable overload protection (70% to 100%) with ROM & spreader, 3 wire suitable for inline connection with LCD display for precise motor start, stop, monitor, control and protection having adjustable settings like initial voltage output between 30-70 % of the nominal voltage, Dual current limit between 200 % and 500 % of the soft starter’s rated full load current with timer, adjustable Ramp in and ramp out time, kick start etc. Soft starter must have integrated motor and load protection features like overload protection with dual overload class settings, high current protection, locked rotor protection, under load protection and torque control feature for precise pump control, 1 No. Aux contractor, 4 No. start push button; 4 No. stop push button, mushroom head; 12 Nos. indicator lamps on/off/trip; 4 No. A/M selector switch; 4 No. control MCB 2 A; 12 Nos. control terminals; 24 Nos. power terminals; 4 No. neutral link

-

-

-

... More
(3) 250 KVAR CAPACITOR BANK

-

-

-

... More
(3) 8 Nos. 25 KVAR capacitor feeder; 8 Nos. 63 A 3 pole MCB 10 kA; 8 Nos. 65 A power contactors; 16 Nos. start/stop push buttons; 16 Nos. indicating lamps ON/OFF; 8 Nos. A/M selector switch, Control MCB 2 A; Neutral Link; Capacitors should be MPP heavy duty

-

-

-

... More
(3) 2 No. 15 KVAR capacitor feeder; 2 No. 40 A 3 pole MCB 10 kA; 2 Nos. 32 A power contactor; 4 Nos. start/stop push buttons; 4 Nos. indicating lamps ON/OFF; 2 No. A/M selector switch, Control MCB 2 A; Neutral Link; Capacitors should be MPP heavy duty

-

-

-

... More
(3) 2 No. 10 KVAR capacitor feeder; 2 No. 40 A 3 pole MCB 10 kA; 2 Nos. 32 A power contactor; 4 Nos. start/stop push buttons; 4 Nos. indicating lamps ON/OFF; 2 No. A/M selector switch, Control MCB 2 A; Neutral Link; Capacitors should be MPP heavy duty

-

-

-

... More
(3) All enclosed in one single unit as per drawing and technical specifications in the section X of the Bid document complete in all respects

-

-

-

... More
Providing and fixing of 3 core copper submersible cable for polder pump of suitable size and the capacity of the cable shall be 1 ½ times than the normal capacity to save it from becoming hot and for longer life usage. It shall also have required number of cable clips and shall be as per IS:694 with latest amendments

240

-

-

... More
Providing and fixing of junction box near to sump wall for connection of pumps of suitable size as per site requirement and to satisfaction of Engineer in charge

8

-

-

... More
Providing and fixing of Aluminium single core armoured cable of 800 sq. mm from Transformer to Incomer ACB of control panel and should be laid in underground trench not less than 1.5 m depth as per norms of PSPCL

180

-

-

... More
Providing and fixing of Aluminium armoured cable of 120 sq. mm 3.5 core from control panel to junction box and should be laid in underground trench not less than 1.5 m depth as per norms of PSPCL

400

-

-

... More
Providing and fixing of MS ‘C’ Class – 200mm dia. ERW type column pipe with both ends of pipes fitted with screwed steel flanges duly welded after screwing with pipes. The thickness of pipe should be confirming to IS 1978-1982 with latest amendments suitable increaser shall be provided with the pump set.

100

-

-

... More
Providing and fixing of common header of 400mm dia. electrically welded steel pipe confirming to IS:3589 with latest amendments for connection of delivery of pumps from sump and fitted as per site requirements complete as shown in attached drawing consisting of 1 No. 400mm D/F MS Bend 90 deg; 1 No. 400mm Sluice Valve PN 10; 1 No. 400mm Non-Return Valve PN 10; MS fabricated Tee 4Nos. 400 x 400 x 200; 1 No. 1.25” socket for Pressure Gauge; 1 No. A/F Tee of 400 X 400 X 100 size and nuts-bolts, gaskets and flanges.

1

-

-

... More
Providing and fixing of common header of 300mm dia. electrically welded steel pipe confirming to IS:3589 with latest amendments for connection of delivery of pumps from sump and fitted as per site requirements complete as shown in attached drawing consisting of 1 No. 300mm D/F MS Bend 90 deg; 1 No. 300mm Sluice Valve PN 10; 1 No. 300mm Non-Return Valve PN 10; MS fabricated Tee 4Nos. 300x 300x 200; 1 No. 1.25” socket for Pressure Gauge; 1 No. A/F Tee of 300 X 300 X 100 size and nuts-bolts, gaskets and flanges.

1

-

-

... More
Providing and fixing of double flanged D.I Sluice valve 8” (200 mm) I/D for delivery line (PN 1.6) complete in all respects. Make: AVK/ IVC / SEEREX /VAG/TCX/Kirloskar

9

-

-

... More
Providing and fixing of double flanged D.I Non-Return valve 8” (200 mm) I/D for delivery line (PN 1.6) complete in all respects. Make: AVK/ IVC / SEEREX /VAG/TCX/Kirloskar.

8

-

-

... More
Providing and fixing of double flanged MS Bend (any degree) 8” (200 mm) I/D for outlet from pump and column ends complete in all respects.

8

-

-

... More
Providing and fixing of D.I. Air Release valve 4” (100 mm) PN 1.6 fitted with flanged connection as per ISI specification on delivery line of common header complete in all respects

2

-

-

... More
Providing, fixing of Maintanance free (Chemical) Earthing with all the allied Material for LT feeder Panel, Tranformer, Genset, VCB, NGR, Busbar Box etc.

16

-

-

... More
Providing and fixing of GI earthing Strip 50 mm x 5 mm clamped/recessed to ground/wall

100

-

-

... More
Providing and fixing of monorail straight travelling trolley including chain pulley block provided with girders having lift up to 12 m, which shall be as per site requirement to take load up to 3 tons

1

-

-

... More
Providing and fixing of M.S. clamps of suitable size to 200 mm dia. Pipe for erection and dismantling of pumps (one pair = two halves) complete in all respect as per specifications

8

-

-

... More
Providing, fixing and commissioning of S.S Pressure Gauge 150 mm dia. of 10 Kg/cm2 glycerin filled with needle valve shall be supplied

2

-

-

... More
Providing & fixing of Electro-magnetic Flowmeter of rated size on pipeline for raw water with fixed/ wall mounted display including wiring complete in all respect; Make: ABB/Siemens/Nivo /Fedral/Forbes Marshall. 400 mm

1

-

-

... More
Providing & fixing of Electro-magnetic Flowmeter of rated size on pipeline for raw water with fixed/ wall mounted display including wiring complete in all respect; Make: ABB/Siemens/Nivo /Fedral/Forbes Marshall. 300 mm

1

-

-

... More
Transformer 800 KVA Supplying, installing, testing and commissioning of 3 phase 50 Hz oil immersed naturally cooled outdoor type copper wound 11/0.433 kV Transformer as per IS:2025 with off load tap changer, Buchholz relay, radiator assembly, silicone gel breather, terminal arrangement, cable box complete in all respect as per as DNIT specification,

1

-

-

... More
Supplying, installing, testing and commissioning of HT Panel consisting of following: 1 No. single break VCB with electrical closing of 11 kV 630 A/ 350 MVA capacity Ammeter, indicating lights, 100/5-5, PT 11 KV/110 V Relay: Over current (2 Nos.), Earth Fault Protection, Digital type emergency tripping, arrangement, on/off selector switch, mechanical on/off release, cable junction box & termination box, control fuse, bus bar foundation of panel etc. complete in all respect as per DNIT specification, Make: ABB/Schneider/Kirloskar/L&T/BHEL/AREVA-PIX

1

-

-

... More
Supplying, installing, testing and commissioning of 11 kV Grade earthed cable of XLPE insulated aluminium conductor (Armoured) of following size as per the specification given in as per IS specification Make: Havells, ICL, CCI,KEI, PolyCab 11 kV Line (G.O Switch) to VCB: 3 core 70 sq. mm HT

65

-

-

... More
Supplying, installing, testing and commissioning of 11 kV Grade earthed cable of XLPE insulated aluminium conductor (Armoured) of following size as per the specification given in as per IS specification

400

-

-

... More
NGR panel for transformer made with sheet steel clad free standing, floor mounted, dust & vermin proof indoor/outdoor type NGR panel manufacturing out of 2mm thick CRCA sheet steel and powder coated with RAL-7032 Siemens grey shade. The panel will have the following component fully bus bared, wired and ready to use. Set punched stainless steel resistors manufactured out of ASTM-A 240-304 grade stainless steel assembled in the form of banks as per DNIT specifications

1

-

-

... More
Providing & fixing H Pole structure having steel tubular poles 2 nos., 10 mtrs long, 168 Kg design 410 sp-44 conforming to IS 2713 part-I, incl. excavation, RCC muff 10” dia 2 meter length of each pole, with C.C.1:4:8, M.S Channel 100X50X6mm (27RFT), M.S Angle 50X50X6mm (30FT), 50X6mm (18RFT), Primer painting complete structure, 11 kV GO Switch with 9 nos. pins, on/off arrangement, lighting arrestors 93 nos. GI pipe earthing 2 nos. 11 kV Fuse wire, making holes in pole, nut and bolts for fixing channels, angles, GI protection pipe, 50 mm 5mtr with clamps, nut and bolts, danger plate with clamps, complete in all respects as per DNIT specifications

1

-

-

... More
Supplying, erection, testing and commissioning of battery bank & battery charger 24V DC Supply capacity of 2 volt, 80 AH lead acid cell, maintenance free type tubular storage battery along with associated accessories, Float cum boost charges 10/16 Amp. Rating and DCDB as per DNIT specifications

1

-

-

... More
Supplying, erection, testing and commissioning of HT kit of cable and joints suitable for HT Cables type Heat shrinking 3 core XLPE cable with required thimbles of same size. The joint should be strictly as per relevant ISI specifications as per DNIT specifications

5

-

-

... More
25) Construction of RCC M25 foundation as per drawing and design to be submitted by the firm for approval by department for the following:

-

-

-

... More
(A) Transformer

1

-

-

... More
(B) H.T. Panel

1

-

-

... More
Providing and Fixing of 4 No. Fire Extinguishers each of 5 Kg capacity CO2 type ISI mark fire extinguisher complete with pressure gauge cylinder and set of 4 No. sand buckets including M.S. stand complete in all respects including painting with red paint, shock treatment guidelines chart as per as DNIT specification

1

-

-

... More
Supplying and fixing of nominal 2.5mm±10% thick fire retardant mats conforming to IS:15652 and meeting the requirement of IS 5216, IS 8437, IEC 479 Pub-I along with suitable adhesive/chemibound resin water proof compound and sealing material as per in service recommendations class-C of IS:15652 and suitable for class A up to 3.3 kV installations as per DNIT specification

1

-

-

... More
Construction of Gravel Yard with fencing as per PSPCL norms

1

-

-

... More
Construction of Grill/gratings/trench covers as per drawing and design to be submitted by the firm for approval by department

500

-

-

... More
Construction of Thrust Blocks on each pump delivery outlet as per drawing and design to be submitted by the firm for approval by department

8

-

-

... More
Providing and Fixing of Level switch in sump with complete wiring and automation/interlocking with panel with WLC

1

-

-

... More
Campus Lighting at site every 10 m as per standard norms. Provision of manual changeover of suitable rating for shifting lighting load/24V DC VCB Battery charger to DG in case of grid power failure (1 Light pole)

10

-

-

... More
Supply, erection, testing and commissioning of 15 KVA capacity silent type water cooled Diesel Gen set including installation/commissioning cost of suitable capacity inbuilt diesel tank, AVM pad with 1 No. industrial silencer, AMF panel, charger and suitable size battery for handling the lightening load at site.

1

-

-

... More
Supply, erection, testing and commissioning of DI flow control Plunger/ needle valve cum regulator valve gear mounted of 800 MM size pressure control valve should work as pressure reducing valve of a higher upstream pressure to constant downstream pressure independent of capacity or flow variation of the upstream .control valve is of through passage design rotationally symmetric flow path annular flow cross section in any open position with linear regulating characteristics axial movement of the plunger is by means of shaft driven with irreversible worm gear box incl position indicator , face to face dimensions as per DIN 3202, F% and flange connection as per DIN 2501-1 along with dismantling joint on the intake point at RD 129.035 km including excavation and fixing of valve at existing HDPE pipe t to maintain required flow required at the sump and required flow and pressure at downstream along with 3 Year DLB

1

-

-

... More
Supply, erection, testing and commissioning of DI Gate valve gear mounted of size 800 MM PN 1.6 along with dismantling joint on the intake point at RD 129.035 km including excavation and fixing of valve at existing HDPE pipe along with the accessories fabricated from 8 mm thick MS sheet towards intake of sump

1

-

-

... More
Supply, erection, testing and commissioning of MS sheet fabricated pipe 400mm dia. of 8mm th plate from header to the rising main including excavation and realigning to the requirement upto 1 meter depth as per site requirement complete in all respect

10

-

-

... More
Supply, erection, testing and commissioning of MS sheet fabricated pipe 300mm dia of 8mm th plate from header to the rising main including excavation and realigning to the requirement upto 1 meter depth as per site requirement complete in all respect

10

-

-

... More
Supply, erection, testing and commissioning of MS sheet fabricated pipe 800mm dia of 8mm th plate from header to the rising main including excavation and realigning to the requirement upto 1 meter depth as per site requirement complete in all respect

10

-

-

... More
Supply, erection, testing and commissioning of Sump dewatering pump for cleaning of sludge in the sump of 2 HP Submersible type including panel and wire and 1.5 " GI pipe to the nearest disposal point upto 20 meters as per site requirement complete in all respect

1

-

-

... More
Providing and fixing of D.I. Air Release valve 8” (200 mm) PN 1.6 fitted with flanged connection as per ISI specification on input 800 mm line towards sump complete in all respects

1

-

-

... More
Supply, erection, testing and commissioning of solar PV plant of 175 KW (as per site plan drawing shown with annexures) on NET metering bases on rooftop. The design of Solar plant to be vetted by PEDA or Reputed approval authority before execution at site as per MNRE specificationsSupply, erection of civil MS fabricated structures for upto 3 m height for Solar plant at item 41 from ground inside Pump house complex complete in all respect.

175

-

-

... More
Any Other item

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.