Water Supply And Sanitation Department Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 55,980Document Cost
Refer DocumentsTender Fee
₹ 3,303
Summary
Augmentation Of Water Supply Scheme Village Hussan Dhut Block And Distt. Ferozepur
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_WB_58386_1Bid Award Id
ViewTender No
Tender for Village Hussan Dhut Block Fzr 1a(iii)Tender Authority
Water Supply And Sanitation Department ViewPurchaser Address
-Website
http://https://www.worldbank.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness.
84
-
-
Supplying, fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked, duly welded with suitable grade S.S. welding electrode to lower the strainer into tubewell bore.
-
-
-
150mm steel strainer (slot size 0.15mm) 5.00 mm thickness
12
-
-
Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI marked duly welded with suitable grade ss welding electrode to lower the strainer into tubewell bore complete in all respect.
-
-
-
150mm Internal diameter
4
-
-
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.
-
-
-
150mm internal diameter
6
-
-
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
1
-
-
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
1
-
-
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.
-
-
-
150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness
4
-
-
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
-
-
-
150mm internal diameter
1
-
-
Development and Stabilizing of the tubwell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
-
-
-
Capacity of Air compressor 300 cfm at 250 PSI
8
-
-
Development and Stabilizing of the tubwell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
6
-
-
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
3
-
-
Colletion of sand sample
3
-
-
Testing of water sample for heavy metal from approval labotary (Toxic material such as Arsenic, lead, Mercury, Pesticides etc).
1
-
-
Boring with 200 mm, 150 & 150 mm i/d MS Casing Pipes and withdrawing the same after completion of Tubewell is required to be Abandoned on the basis of non Availability of Portable water.
100
-
-
Constructing one No. OHSR of 15 KL (15000 litres) Capacity with sill level not less than 13.00m and height upto FSL 15.50 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single manhole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing C.I. D/F expansion joints conforming to (IS-1536-1989) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed typical drawing. Duck foot bends, Conforming to ISI - 13382 and C.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow CI double flanged pressure pipes horizontally cast in sand moulds as per IS 7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium ladder inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil is greater than or equal to 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm., The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling within lead of 5 km, including overflow haudi complete in all respects.
1
-
-
Construction of Pump Chamber size 2.50x2.50m Without gravel pit but including electric wiring complete in all respects.
-
-
-
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
6.31
-
-
Cement concrete 1:8:16
1.91
-
-
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
5.14
-
-
Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded
1.95
-
-
Plastering on underside of ceiling 10mm thick cement plaster 1:3
1.5
-
-
Steel work fixed independently without connecting plates including cutting hoisting and fixing in position
-
-
-
R.S. Joists
0.9
-
-
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
6.73
-
-
Cement concrete 1:2:4
0.88
-
-
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
6.25
-
-
Conglomerate floor 25mm thick cement concrete rete 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling. using mechanical mixer for mixing of material
6.81
-
-
12.5 mm thick cement plaster 1:4
74.4
-
-
10mm thick cement plaster 1:3 on floors.
8.42
-
-
Bansam Champ (Assam) doors with 12mm thick phenol Bonded BWP ply ISI Marked anchor, Kit ply, Nova Teak, National Or equivalent including Hinges, Screws, Shocks Cleats, Stops and Cords etc. complete fixed in position (Single
Leaf)
6.78
-
-
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
15.25
-
-
Painting two coats Qty as per item No 14
15.25
-
-
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
0.93
-
-
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
0.8
-
-
White washing (Three coat)
82.82
-
-
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
2.19
-
-
Providing and fixing cast iron 100mm dia, rain water pipe with screw and wooden plugs fixed on wall-face, including filling joints with spun yarn and cement mortar 1:2 excluding head and shoe etc.
1
-
-
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
1
-
-
Providing and fixing cast iron head for rain water pipe on wooden plugs fixed on wall-face including filling the joints with spun yarn and cement mortar 1:2.
1
-
-
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FRLS cable (ISI marked), 1100volts grade to be laid in heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc
-
-
-
Wiring fan point without fan box in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with s
1
-
-
Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade.
1
-
-
Wiring 3 Pin 6 Amp. Plug control comprising wall socket and switch including bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade complete.
1
-
-
Prov. & fixing of ceiling fan of reputed make such as Crompton or Equivalent.
1
-
-
Prov. & fixing meter Box. Etc.
1
-
-
Prov. & fixing tube light set & CFL electric bulbs 2 Nos. & 1 Set Tube light complete in all respects.
1
-
-
Extra provision for sanitary latrine near pump chamber
1
-
-
Pumping Main PVC Pipe 10Kg/ Cm2
-
-
-
Providing, Stringing out PVC pipes 10 kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width Complete in all respect. (Mechanically ) (10kgf/ cm2) Pressure
-
-
-
110 mm o/d PVC pipe
25
-
-
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
-
-
-
110mm o/d
2
-
-
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (2 no. each of size 0.6m x 0.60m
2
-
-
CONSTRUCTION OF V-NOTCH HAUDI.(size 1.80 rn x 0.90 excluding cost V-notch as per standard design & drawings of public health department D-06.
1
-
-
Pipe Line for Distribution Main
-
-
-
Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications.(as per AC slip no 11) for Manually Excavation including speicals (6kgf/ cm2) Pressure
-
-
-
PVC pipe 63mm o/d PVC 6 kg/cm2
79
-
-
Providing, Stringing out PVC pipes 6kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width. (Mechanically ) (6kgf/ cm2) Pressure
-
-
-
PVC pipe 63mm o/d PVC 6 kg/cm2
1113
-
-
PVC pipe 90mm o/d PVC 6 kg/cm2
609
-
-
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position. Manually Excavation
-
-
-
63mm PVC Pipe
343
-
-
90mm PVC Pipe
539
-
-
Dismantling of cement concrete road and restoration in original condition.
393
-
-
Contractor shall quote rates only for dismantling of metalled road and back filling with excavated earth, fully compacted. The restoration of the metalled road to its original condition will be done by the concerned department I.e PWD (B&R)/PMB/ Panchayti Raj.
-
-
-
PVC pipe
484
-
-
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
-
-
-
80mm I/d
3
-
-
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 1 No. With each of Size 0.6m x 0.6m
3
-
-
HOUSE SERVICE CONNECTIONS
-
-
-
Water Connection Providing proposed water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d=2.50 mtr B- Class as per CSR 28.36 (A),( Above GL), Prov. & fixing MDPE pipe 15mm i/d with specials 2.00 Mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b)
67
-
-
Providing,fixing & jointing multijet water meter of approved make as per IS:779/94 in G.I.Pipe line including cutting and threading pipe including cost of water meter but excluding cost of specials, Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages, 15mm i/d Brass Ball valves of G.I. Nipple 15mm x 150mm, Supply of G.I. Nipple 15mm x 100mm, Supply of G.I. elbow 15mm i/dia ISI Marked Providing, fixing and jointing Union Couplings in G.I. Pipe Lines Providing & Fixing G.I. Hooks comlplete in all respect.
67
-
-
Chlorination and Disinfection
-
-
-
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications. Along with 200ltr of sodium hypochlorite in container.
1
-
-
Pumping Machinery
-
-
-
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 64 LPM against a head of 37.00mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 50 mm & length 20 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 60 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2005 complete in all respects
1
-
-
Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as per Drawings D-16.
1
-
-
SOLAR PANEL
-
-
-
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
3
-
-
Development of Head Works
-
-
-
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-09.
243
-
-
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. including carriage of material
33
-
-
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-11.
30
-
-
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-12. including carriage of material
4
-
-
Construction of masonry gate pillar including cost of MS Steel gate size 1.37 m x1.22 mtr. as per standard Drawing. D-10
1
-
-
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing attached. including carriage.
25
-
-
Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-14.
1
-
-
Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish
-
-
-
Carriage of material excluding initial lead of 5 Km
-
-
-
Fine Sand From Jalalabad (Av. Lead 60 Km)
11.83
-
-
Course Sand From Pathankot (Av Lead 225 Km.)
0.95
-
-
Bajri / Gatka From Pathankot (Av Lead 225Km.)
10.61
-
-
Operation and Maintenance of Water Supply for 3 months after completion of works including cost of Alum, liquid chlorine etc. excluding electircitycharges.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements