Punjab Water Supply And Sewerage Board Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Punjab Water Supply And Sewerage Board - PWSSB Tender

Coronavirus COVID 19
Eprocure
Opening Date8 Mar 2019
Closing DateCancelled
Tender Amount₹ 97,60,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation in Soil (any type) using Hydraulic Excavator CK 90. Excavation with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, Including all lifts and combined lead up to 60m.

-

-

-

... More
Supplying, lowering MS Pipe :

-

-

-

... More
Supplying, lowering of MS Pipe as per IS: 3589-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tube well bore complete in all respect.A&C-11

-

-

-

... More
323.9 mm. outer diameter (weight 55.50 kg per metre) 7.1 mm. thickness.

-

-

-

... More
Supplying, lowering MS Special Socket :

-

-

-

... More
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.

-

-

-

... More
200mm internal diameter

-

-

-

... More
Supplying and fixing of MS Clamp :

-

-

-

... More
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.

-

-

-

... More
Supplying Wooden Box :

-

-

-

... More
Supplying at site Wooden Box of suitable size with Lid & locking arrangement for preserving strata sample collected from the bore.

-

-

-

... More
Supplying and fixing of MS Bail Plug :

-

-

-

... More
Supplying & Fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respects.

-

-

-

... More
200 mm. internal diameter (weight 41.6 kg./metre) 8.00 mm. thickness.

-

-

-

... More
Supplying and fixing of MS Taper/Reducer :

-

-

-

... More
Providing and fixing M.S. taper/ reducer made out of 6mm thick M.S. sheet complete in all respect.

-

-

-

... More
Reducer 350mm x 200 mm

-

-

-

... More
Supplying and fixing of Well Cap :

-

-

-

... More
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.

-

-

-

... More
350mm internal diameter

-

-

-

... More
Development & Stabilizing of Tube well with Air Compressor :

-

-

-

... More
Development and Stabilizing of the tube well with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.

-

-

-

... More
Capacity of Air compressor 300 cfm at 250 PSI

-

-

-

... More
Development & Stabilizing of Tube well with Submersible Pump :

-

-

-

... More
Development and Stabilizing of the tube well with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.

-

-

-

... More
Drilling of Tube well by Reverse Rotary Rig : 600 mm. dia.

-

-

-

... More
Drilling of 600 mm dia. bore with Reverse Rotary Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. Complete in all respect.

-

-

-

... More
Drilling of 600 mm dia. bore with Reverse Rotary Rig Up to 150m depth BGL.

-

-

-

... More
Drilling of 600 mm dia. bore with Reverse Rotary Rig Beyond 150m depth BGL up to 300 Mtr.

-

-

-

... More
Temporary Water Supply Connection :

-

-

-

... More
Making temporary water supply arrangement for drilling of tube well with reverse rotary rig till completion of bore & packing of gravel

-

-

-

... More
Depth of temporary bore up to 90 m.

-

-

-

... More
Supplying of Gravel :

-

-

-

... More
Supplying of gravel of 1/16" to 1/8" sizes including pipes assembly and the bore. The gravel should be free from dust, dirt or the vegetable manner as per IS: 4097/1967 with latest amendments. (Rate include loading & unloading). Carriage from quarry site will be paid extra as per actual. Note: The rate includes loading & unloading charges. Carriage from quarry will be paid extra as per actual.

-

-

-

... More
Supplying & fixing of MS centering Guides :

-

-

-

... More
Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.

-

-

-

... More
Supplying, assembling, lowering & fixing in vertical position uPVC well casing pipe :

-

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.

-

-

-

... More
200 mm nominal size dia

-

-

-

... More
Supplying, lowering of uPVC medium well screen (RMS) pipe :

-

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.

-

-

-

... More
200 mm nominal size dia

-

-

-

... More
Providing and laying 'C' Class heavy duty MS Pipe: Column Pipe :

-

-

-

... More
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts, bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects.

-

-

-

... More
150 mm. Internal Diameter.

-

-

-

... More
Construction of Gravel Pit :

-

-

-

... More
Construction of Gravel Pit outside the Pump Chamber.(0.90 m. Dia.) as per standard design & drawings of public health department.

-

-

-

... More
Making Electric Logging of Borehole :

-

-

-

... More
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc. complete in all respect.

-

-

-

... More
Total for Bill No.-1 (Drilling of Tube Well) :

-

-

-

... More
Bill No.-2 Pump Machinery of Tube Well :

-

-

-

... More
Providing & fixing Submersible Pump Set : 900 LPM & 75 Mtr. Head

-

-

-

... More
Providing and Fixing of Approved Make Submersible Pump set having discharge 900 LPM at 75 Mtr. Head complete in all respect at site.

-

-

-

... More
Providing & fixing Submersible Pump Set :1800 LPM & 55 Mtr. Head

-

-

-

... More
Providing and Fixing of Approved Make Submersible Pump set having discharge 1800 LPM at 55 Mtr. Head complete in all respect at site.

-

-

-

... More
Providing & fixing Submersible Pump Set :1800 LPM & 75 Mtr. Head

-

-

-

... More
Providing and Fixing of Approved Make Submersible Pump set having discharge 1800 LPM at 75 Mtr. Head complete in all respect at site.

-

-

-

... More
Providing & fixing DI Specials for Delivery line and other accessories :

-

-

-

... More
Providing and laying D.I. special up to 300 mm i/d

-

-

-

... More
C.I. Base plate

-

-

-

... More
Providing & fixing of C.I./D.I.Flanged end, stem of SS (A/S 1410) ISI marked 14846-2000 Sluice Valve 150mm PN-1.0 as per ISI

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all cartages complete. C.I.Double air valve (Size 50 mm)

-

-

-

... More
Bolts and nuts of all sizes and length required.

-

-

-

... More
Rubber Jain of 5mm thickness in accordance with IS 638-1979

-

-

-

... More
Providing & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS : 5312/2004 Class PN-1.0 as per ISI with gun metal flap 150 mm.i/d.Non-return valve.

-

-

-

... More
Providing and fixing 6" dia D/F M.S nipple 1.0 ft. long suitable for column pipe & D.I fitting

-

-

-

... More
Providing, Stringing out,cuting,jointing and testing of ISI Marked D.I.Double Flanged pipes with screwed flanged as per IS : 8329-2000,Class K-9 and laying the same… 150 mm.i/d.pipe lines laid complete.

-

-

-

... More
Total for Bill No.-2 (Pumping Machinery) :

-

-

-

... More
Bill No.-3 Replacement of Pump Machinery of Tube Well :

-

-

-

... More
Replacement : Providing & fixing Submersible Pump Set :1800 LPM & 55 Mtr. Head

-

-

-

... More
Providing and Fixing of Approved Make Submersible Pump set having discharge 1800 LPM at 55 Mtr. Head complete in all respect at site.

-

-

-

... More
Replacement : Providing & fixing Submersible Pump Set :1800 LPM & 75 Mtr. Head

-

-

-

... More
Providing and Fixing of Approved Make Submersible Pump set having discharge 1800 LPM at 75 Mtr. Head complete in all respect at site.

-

-

-

... More
Total for Bill No.-3 (Replacement of Pumping Machinery) :

-

-

-

... More
Bill No.-4 Construction of Pump Chamber :

-

-

-

... More
Earthwork in excavation in foundation :

-

-

-

... More
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 meter depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edges of excavation and subsequent filling around masonry in 1.5. layers with compaction including disposal of all surplus soil as directed within a lead of 30 meter.

-

-

-

... More
CC 1:6:12 with 40 mm. gauge stone aggregate :

-

-

-

... More
Cement Concrete 1:6:12 with 40 mm. gauge stone aggregate using concrete mixer volumetric type.

-

-

-

... More
Brick Masonry in CM 1:7 :In Foundation and Plinth :

-

-

-

... More
First Class burnt brick laid in cement sand mortar 1:7 in foundation and plinth.

-

-

-

... More
DPC 40 mm. thick :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg./Sq. m.... Laid hot and sanded.

-

-

-

... More
Brick Masonry in CM 1:5 : In Superstructure :

-

-

-

... More
First Class burnt brick laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

-

-

-

... More
DPC 20 mm. thick :

-

-

-

... More
20 mm. thick cement plaster in damp proof course 1:3 with two coats of bitumen at 1.65 kg/Sq. m.... Laid hot and sanded.

-

-

-

... More
Vertical

-

-

-

... More
RCC M-15 :

-

-

-

... More
Reinforced cement concrete M-15 mechanically batch mixed using batch type concrete mixture as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering in superstructure.

-

-

-

... More
Specially Moulded Brickwork in Circular work :

-

-

-

... More
Extra for specially moulded brick work in circular work such as well shafts, circular sumps, pump chambers etc.in which specially moulded or cut bricks have to be used but for which no centring or supports are required up to 4.5 meter internal Diameter.

-

-

-

... More
Door and Window Wood Shutters ( Kali Wood) : 40 mm. thick

-

-

-

... More
Kali wood doors shutter and window shutter (i) panelled, glazed or glazed and panelled including hinges screws chokes cleats and cords etc. complete fixed in position. (Single Leaf)

-

-

-

... More
40mm thick.

-

-

-

... More
Wire Gauge Door Shutters : 35 mm. thick

-

-

-

... More
Wire gauge door shutter with Kali wood without springs housed in chowkhts. ( Single Leaf)

-

-

-

... More
35mm thick

-

-

-

... More
Aluminium Fittings :

-

-

-

... More
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handles and screw etc. for these fittings.(Excluding sliding bolt)

-

-

-

... More
For shutter area above 0.50 Sq. m...

-

-

-

... More
Iron Work for Grills :

-

-

-

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.

-

-

-

... More
Earth filling :

-

-

-

... More
Earth filling under floors with surplus ordinary soil or soil containing gravel or kanker up to 40% excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead up to 30 meters.

-

-

-

... More
Steel Work :

-

-

-

... More
Steel work, fixed independently without connecting plates, including cutting, hoisting and fixing in position.

-

-

-

... More
Reinforced Steel Joists :

-

-

-

... More
R.S. Joists

-

-

-

... More
Steel Work in Tees, Angles & Channels :

-

-

-

... More
Tees, angles and channels.

-

-

-

... More
Centering and shuttering for flat surfaces :

-

-

-

... More
centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.

-

-

-

... More
Centering and shuttering for sides & soffits of Beam :

-

-

-

... More
Centering and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels

-

-

-

... More
Conglomerate floor 40 mm. thick :

-

-

-

... More
Conglomerate floor 40 mm. thick cement concrete rate 1:2:4 on 100 mm. thick cement concrete 1:8:16 and 100 mm. sand filling.

-

-

-

... More
Floating coat of 1.5 mm thick neat cement:

-

-

-

... More
Floating coat of 1.5 mm thick neat cement laid in one operation to the topping.

-

-

-

... More
Primer Coat on Wood Work :

-

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc.

-

-

-

... More
with ordinary quality paint

-

-

-

... More
Synthetic Enamel Paint on Wood Work :

-

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work. Metallic or plastered concrete surface to give an even shade.

-

-

-

... More
with ordinary quality paint

-

-

-

... More
Primer Coat on Metal Surface :

-

-

-

... More
Applying priming coat with metal primer on new steel or iron work including preparation of surface.

-

-

-

... More
with ordinary quality paint

-

-

-

... More
Painting On Metal Surfaces :

-

-

-

... More
Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.

-

-

-

... More
with ordinary quality paint

-

-

-

... More
CC 1:2:4 Gola : 10 cm.x10 cm. Concave :

-

-

-

... More
Cement concrete 1:2:4 gola 10 cm.x10 cm. concave quadrant along junction of roofs with parapet wall finished smooth where specially specified.

-

-

-

... More
Cement Plaster 1:4 (12.5 mm. thick) :

-

-

-

... More
12.5 mm. thick cement plaster 1:4

-

-

-

... More
Grey Polished Skirting : 20 mm. thick

-

-

-

... More
20 mm. thick grey polished skirting or dado consisting of bottom layer of 16 mm. thick cement sand plaster 1:3 and finished 3 mm. thick topping of neat cement rubbed and polished including rounding of junction with floors.

-

-

-

... More
Terracing of Tiles : 22.86x11.43x3.83 cm.

-

-

-

... More
Terracing consisting of tiles 22.86x11.43x3.83 cm. laid over 25 mm. mud plaster 7.5 cm. mud filling on another layer of 25 mm. mud plaster including two coats of bitumen laid hot at 1.65 kg./Sq. m.... Top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.

-

-

-

... More
White washing (Three coat) :

-

-

-

... More
White washing (Three coat)

-

-

-

... More
Foot Rest :

-

-

-

... More
Foot Rest for pump chamber

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C Rain water pipe ( Ring fitted type-A) as per IS : 13592 including jointing:

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C Rain water pipe ( Ring fitted type-A) as per IS : 13592 including jointing during masonry complete as per specifications and to the entire satisfaction of Engineer-in-charge.(If fixed on wall face clamp to be paid separately as per respective item)

-

-

-

... More
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per IS:4985-2000, including specials :

-

-

-

... More
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per IS:4985-2000, including specials such as tees, bends, sockets, elbows etc. cutting, testing ( including cost of specials) in the ground complete in all respects.

-

-

-

... More
uPVC Pipe 6 kgf/cm2

-

-

-

... More
50 mm.i/d.

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C bend for Rain water pipe as per IS : 14735 including jointing :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C bend for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C Coupling/Socket for Rain water pipe as per IS : 14735 including jointing :

-

-

-

... More
Providing and fixing 110 mm. dia. SWR U.P.V.C Coupling/Socket for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge.

-

-

-

... More
Distempering with dry distemper:

-

-

-

... More
Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade.

-

-

-

... More
Priming Coat with Cement Primer :

-

-

-

... More
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface.

-

-

-

... More
Exterior Decorative Cement Based Paint :

-

-

-

... More
Finishing walls with exterior decorative cement based such as snowcem, robbiacem etc. on old work two coat to give an even shade.

-

-

-

... More
Preparation of plastered surfaces for distempering:

-

-

-

... More
Preparation of plastered surfaces for distempering including surface applying filling with approved quality filler consisting of plaster of Paris and chalk mitti including finishing the surface to the required finish complete.

-

-

-

... More
Top Khurra 0.6 m.x0.6 m. :

-

-

-

... More
Top Khurra 0.6 m.x0.6 m. for rain water pipe in 25 mm. thick cement concrete 1:2:4 over 50 mm. thick cement concrete 1:8:16.

-

-

-

... More
Cold twisted deformed ( ribbed/tor steel) Bars Fe 500 grade as per IS : 1786-2008 :

-

-

-

... More
Cold twisted deformed ( ribbed/tor steel) Bars Fe 500 grade as per IS : 1786-2008 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete.

-

-

-

... More
Supply & Fixing of Pressed Steel Frames

-

-

-

... More
( Chowkats) consisting of 18 gauge (1.25 mm.) :

-

-

-

... More
Supply & Fixing of pressed steel frames ( Chowkats) consisting of 18 gauge (1.25 mm.) thick steel sheet of the specified section ( standard design latest) including iron lugs ( hold fasts),iron hinges, conforming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, hydraulic spring and finished with one priming coat of approved quality fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete.

-

-

-

... More
Doors and windows frame of size 118 mm.x60 mm. with 40 mm. wide single rebate weighing 3.43 kg. Per meter.

-

-

-

... More
Doors and windows frame of size 151mm.x60 mm. with 35 mm. wide double rebate weighing 3.95 kg. Per meter.

-

-

-

... More
Supplying and fixing glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

-

-

-

... More
Glass panes 4 mm. thick above 0.40 Sq. m.... area.

-

-

-

... More
Ceiling Plaster in CM 1:3 :

-

-

-

... More
Plastering on underside of ceiling 10 mm. thick cement plaster 1:3

-

-

-

... More
Providing & Fixing FRP dome opening of size 4'-6" x 4'-6".

-

-

-

... More
Total for Bill No.-4 (Pump Chamber) :

-

-

-

... More
Bill No.-5 Construction of Boundary Wall :

-

-

-

... More
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 meter depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edges of excavation and subsequent filling around masonry in 1.5. layers with compaction including disposal of all surplus soil as directed within a lead of 30 meter.

-

-

-

... More
Cement Concrete 1:6:12 with 40mm gauge stone aggregate using mixer volumetric type

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

-

-

-

... More
Damp proof course 4 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per Sqm laid hot and sanded.

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

-

-

-

... More
12.5 mm thick cement plaster 1:4

-

-

-

... More
Cement pointing 1:2 deep variety.

-

-

-

... More
Cement Concrete 1:2:4 with stone ballast or shingle using mixer volumetric type.

-

-

-

... More
Finishing walls with exterior decorative cement based paints such as snowcem roobiscem etc. on new work coats to give an even shade

-

-

-

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.

-

-

-

... More
Applying priming coat with metal primer on new steel or iron work including preparation of surface.

-

-

-

... More
with special quality paint.

-

-

-

... More
Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.

-

-

-

... More
with special quality paint.

-

-

-

... More
Total for Bill No.-5 (Boundary Wall) :

-

-

-

... More
Bill No.-6 Chlorinator Dosing Pump :

-

-

-

... More
Providing & fixing dosing pump solenoid driven type adjusted via micro meter knob 100 or 20%capacity pushbuttons selector stabilized multi power supply 100-240 volts single phase 50/60 Hz (2.5-3.0 Litre. /hr. vs. 18-20 bar) of reputed make complete in all respect.

30

-

-

... More
Total for Bill No.-6 :

-

-

-

... More
Bill No.-7 Breakup of SCADA Room :

-

-

-

... More
Earthwork in excavation of foundations :

-

-

-

... More
Earthwork in excavation of foundations of bridges, culverts, building including handling of materials with combined lead of 15 metres dressing of bed and sides stacking the excavated soil clear from the edge of excavation and subsequent filling :

-

-

-

... More
In foundation :

-

-

-

... More
For ordinary gravel soil involving pick work:

25.93

-

-

... More
PCC : CC.1:2:4 :

-

-

-

... More
Cement Concrete 1:2:4 with stone ballast.

4.76

-

-

... More
RCC M-20 :

-

-

-

... More
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixture as per IS :1791 and vibrated by needle vibrator but excluding steel reinforcement, centring and shuttering in foundation and plinth.

3.51

-

-

... More
Shuttering :

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

15.81

-

-

... More
Steel :

-

-

-

... More
Cold twisted deformed (Ribbed/Tor Steel Bars) Fe 500 grade as per IS 1786-2008 for RCC works, where not including in the complete rate of RCC including bending and placing in position complete.

11.43

-

-

... More
Brick work in CM 1:5 :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

12.457

-

-

... More
Damp proof course :

-

-

-

... More
Damp proof course 4 cm. thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration at 1.65 kg per Sq. m.... laid hot and sanded.

8.74

-

-

... More
Brick work in CM 1:5 :

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

11.068

-

-

... More
115 mm. thick Brick work :

-

-

-

... More
115 mm. thick brick wall laid in cement ,lime, sand mortar 1:1:6 ( One Cement, one lime, six sand) in superstructure up to 4 metres above plinth level.

9

-

-

... More
RCC M-30 :

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixture as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, centring and shuttering in superstructure.

10.785

-

-

... More
Centring and Shuttering :

-

-

-

... More
Centering and Shuttering : for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc. :

-

-

-

... More
Centring and Shuttering :

-

-

-

... More
Centering and Shuttering : for sides and soffits of beam,beams,launchings,girders,bressumers,lintels.

-

-

-

... More
Centring and Shuttering :

-

-

-

... More
Centering and Shuttering : for columns.(Square or Rectangular or Poly Gonal in plan)

-

-

-

... More
20 mm. thick cement plaster 1:2 in two coat work.

79.254

-

-

... More
12.5 mm. thick cement plaster 1:2 .

129.115

-

-

... More
White washing (Three coat)

208.369

-

-

... More
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of Paris and chalk mitti, including finishing the surface to the required finish complete.

208.37

-

-

... More
Distempering :

-

-

-

... More
Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade.

79.25

-

-

... More
Oil Bound Distemper :

-

-

-

... More
Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.

129.12

-

-

... More
Earth filling under floors :

-

-

-

... More
Earth filling under floors with surplus soil containing more than 40% gravel or kanker excavated from foundation and taken only from outside the building plinth in 15 cm. layers including ramming, watering and consolidating lead uptom30 metres.

18.63

-

-

... More
Anti-Skid Tiles Flooring :

-

-

-

... More
Anti-skid floor tiles 10 mm. thick in flooring, skirting and dado in 12.5 mm. thick cement plaster 1:3 in base and jointed with white cement slurry in joints including corners, angles and beading.

2.88

-

-

... More
Vitrified Floor Tiles Flooring :

-

-

-

... More
Providing and laying vitrified floor tiles 600*600 mm. manufactured size using Premium Soluble Salt Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20 mm. thick cement mortar 1:4 ( 1 cement : 4 fine sand) for new flooring laid with cement based high polymer modified quick set tile adhesive ( water based) of approved make IS :15477 marked using 5 kg. adhesive per Sq. m.... of tile area in average 3 mm. thickness over existing base etc. complete.(Design is homogenous throughout the tile body)

32.83

-

-

... More
Providing and fixing ceramic glazed wall tiles :

-

-

-

... More
Providing and fixing 1 st quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness manufacture to of be specified by approved make in thaall colours, shades except burgundy, bottle green, black of size 100x200 mm.,200x200 and 200x300 mm.as approved by Engineer-In-Charge in skirting, risers of steps and dados over 12 mm. thick bed of cement mortar 1:4 ( 1 cement : 4 fine sand) and jointing with grey cement slurry @ 3.3 kg/Sq. m... including pointing in white cement mixed with pigment of matching shade.

9.68

-

-

... More
Supplying & Fixing Steel Windows and Ventilators :

-

-

-

... More
Supplying & fixing fixed steel windows of standard rolled steel sections joints mitred and electrically flash welded including iron lugs and glazing clips, labour for fixing during masonry complete (excluding glazing) and fixing with two coats of ready mixed paint, red lead non-setting primer.

204

-

-

... More
Fixing of Glass panes :

-

-

-

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.

-

-

-

... More
Glass panes 4 mm. thick above 0-40 Sq. m.... area.

18.23

-

-

... More
Hollock Wood Doors :

-

-

-

... More
Kiln seasoned Hollock wood doors shutter with 12 mm.thick phenol Bonded BWP ply ISI Marked anchor, Kit ply, Nova Teak, National or equivalent including Hin ges, Screws, Shocks, Cleats, Stops and Cords etc. complete fixed in position.(Single Leaf)

-

-

-

... More
Phenol Bounded B.W.P. ply panel :

-

-

-

... More
40 mm. thick

7.34

-

-

... More
Applying pink primer or aluminium priming coat on wood work :

-

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc.

-

-

-

... More
With special quality paint

29.34

-

-

... More
Painting Synthetic Enamel Paint on Wood work :

-

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

-

-

-

... More
With special quality paint

29.34

-

-

... More
Painting on Steel work :

-

-

-

... More
Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.

-

-

-

... More
With special quality paint

72.9

-

-

... More
Providing and fixing in position Chinaware European type :

-

-

-

... More
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make ( to the approval of the Engineer-in-charge) consisting of 10 litres PVC flushing cistern, PVC short bend 32 mm. dia. including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.

1

-

-

... More
Providing and fixing in position Metro pole flush valve :

-

-

-

... More
Providing and fixing in position Metro pole flush valve 32 mm. size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect.

1

-

-

... More
Providing and fixing in position vitreous Chinaware sinks :

-

-

-

... More
Providing and fixing in position vitreous Chinaware sinks of approved make ( to the approval of the Engineer-in-charge) consisting of 40 mm. i/d. C.P. brass waste, pair of brackets complete in all respects.

-

-

-

... More
Size 610 mm.*450 mm.200 mm.

1

-

-

... More
Providing Opening for Wash Basin :

-

-

-

... More
Providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, verity counter and similar location in marble/granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of out edges etc. complete.

1

-

-

... More
Providing and fixing Paper holders :

-

-

-

... More
Providing and fixing in position paper holders of approved make ( to the approval of Engineer-in*charge) fixed in to wall with C.P. brass screws complete in all respect.

-

-

-

... More
C.P. brass toilet paper holder

1

-

-

... More
Providing and fixing Towel rails/Rings :

-

-

-

... More
Providing and fixing in position towel rails/ring of approved make ( to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.

-

-

-

... More
C.P. brass towel Rails size : 15 mm. dia. 600 mm. long.

1

-

-

... More
C.P. brass towel ring.

1

-

-

... More
Providing and laying G.I. Pipe lines :

-

-

-

... More
Providing, laying ,jointing ,fixing and testing ISI Marked G.I. Pipe (as per IS : 1239) B-Class Premium make such as (Jindal, Hisar) including cost of specials ( such as tees, bends, sockets, elbows et) painting with anti corrosive bitumen tic paint, testing, cutting, threading inside building complete.

-

-

-

... More
15 mm. i/d.

30

-

-

... More
20 mm. i/d.

20

-

-

... More
Providing and fixing 15 mm. i/d. Bib-cock : :

-

-

-

... More
Providing & Fixing in position 15 mm.i/d. Bib-cock of approved make (to the approval of Engineer-in-charge) complete in all respects.

-

-

-

... More
PTMT Tap/Bib cock

1

-

-

... More
Cutting chase in brick walls in cement or in floor :

-

-

-

... More
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I. pipes line and making good the same to it's original condition.

-

-

-

... More
Size 150 mm.*150 mm.

20

-

-

... More
Size 225 mm.*225 mm.

20

-

-

... More
Providing and fixing C.P. Acrylic shelf :

-

-

-

... More
Providing and fixing in position C.P. Acrylic shelf with C.P. bracket and guard rails of approved make ( to the approval of Engineer-in-charge) fixed in with rawl plugs and C.P. brass screws complete in all respect.

-

-

-

... More
C.P. Acrylic Shelf size : 560 mm.*130 mm.

1

-

-

... More
Providing and fixing C.P. Brass soap dish :

-

-

-

... More
Providing and fixing in position C.P. brass soap dish of approved make ( to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P. brass screws complete in all respect.

1

-

-

... More
Providing and fixing in position Mirror of superior glass :

-

-

-

... More
Providing and fixing in position 5 mm. thick bevelled edge mirror of superior glass (of approved make) complete with 4 mm. thick hard board backing fixed in with rawl plugs 50 mm. C.P. brass screws and washers complete in all respect.(as required by the Engineer-in-charge).

-

-

-

... More
Size: 1500 mm.*600 mm. or any other size.

1

-

-

... More
Providing and fixing Liquid soap container :

-

-

-

... More
Providing and fixing in position liquid soap container (of approved make) (to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
C.P. brass liquid soap container

1

-

-

... More
Providing and fixing Stop cock/Angle valve :

-

-

-

... More
Providing and fixing in position stop cock/Angle valve of approved make( to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
C.P. brass 15 mm. Concealed stop cock with flange.

2

-

-

... More
Providing fixing G.M. ferrule :

-

-

-

... More
Providing ISI Marked G.M. Ferrule as per IS :2692 drilling and tapping cast iron pipe lines of all diameters and screwing in Ferrule and connections complete in all respect.

-

-

-

... More
15 mm .i/d. Ferrule medium

1

-

-

... More
20 mm. i/d. Ferrule medium

1

-

-

... More
Providing fixing HDPE Water Storage Tank :

-

-

-

... More
Providing and placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make ( to the approval of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet outlet and over flow pipes but without fittings and base support for tank.

-

-

-

... More
Triple Layer Tanks

2000

-

-

... More
Providing fixing HDPE Water Tank Cover :

-

-

-

... More
Providing and fixing in position on terrace (at all floor levels) HDPE tank cover for water storage tanks of approved make ( to the approval of Engineer-in-charge) complete in all respect.

-

-

-

... More
For 1000 litre. capacity tank and above.

1

-

-

... More
Providing fixing G.I. Tank Nipple :

-

-

-

... More
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respects. complete in all respect.

-

-

-

... More
G.I. tank nipple 20 mm. i/d.

1

-

-

... More
Providing fixing Automatic Brass Ball Cock in tanks :

-

-

-

... More
Providing and fixing in position automatic brass ball cock in tank :

-

-

-

... More
Brass Ball Cock with rod and Plastic ball :

-

-

-

... More
20 mm. i/d.

1

-

-

... More
Providing and fixing in position grating :

-

-

-

... More
Providing and fixing in position grating of approved make ( to the approval of Engineer-in-charge) size 150 mm.*150 mm. for gully trap.

-

-

-

... More
H.C.I. grating including painting with black bitumen tic superior paint of approved manufacture three coats.

1

-

-

... More
Providing, lowering, cutting &jointing Salt Glazed Stone Ware pipes and specials :

-

-

-

... More
Providing, lowering, cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS :651-2007 class Sp-1 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching, hunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun jute yarn as per IS :1887,finishing and troweling of each joint at an angle of 45 degree with the longitudinal axes of pipe, watering, keeping the joint covered and wetted till the same are cured, testing the sewerage line for leakage and making all leakages and defects good as laid in the correct specification.......

-

-

-

... More
150 mm. i/d pipes.

10

-

-

... More
Construction of Soak-Pit :

-

-

-

... More
Constructing soak pit 2.50 m. outer Dia. 3.0 metre deep 230 mm. thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm.Diametre,1.8 mt. long complete as per standard design.

1

-

-

... More
Providing, Fixing RCC Road Gully Grating & Frame :

-

-

-

... More
Providing & Fixing RCC Road Gully grating & frame

-

-

-

... More
600 mm.*300 mm.

1

-

-

... More
Plaster of Paris Ceiling :

-

-

-

... More
Plaster of Paris ceiling 12.5 mm. thick consisting of 12.5 mm. thick panels of plaster of Paris reinforced with hessian cloth fixed to under side of cradling of specified design, including cost of fixing in position all materials. etc.(cost of cradling to be paid separately)

36.12

-

-

... More
GI Cradling :

-

-

-

... More
Providing and Fixing ceiling consisting of 600 mm.*600 mm.*12.5 mm. thick Gypsum Board GI Cradling hanged from the ceiling by means of GI hanger complete as per drawings, specifications and to the entire satisfaction of Engineer-in charge.

36.12

-

-

... More
Accessories Required :

-

-

-

... More
LT Panel with Incomer MCCB,Surge Protection Device,Automatic Transfer Switch and Required Outgoing etc. with Cables as per scope of work & specification.

1

-

-

... More
10 KVA Silent DG set complete with engine, alternator, base frame, radiator, fuel tank, control panel, AMF panel, fuel piping, foundation, all electrical interconnection, loop Earthing, silencer pipe/Exhaust chimney as per CPCB norms, standard accessories and acoustic enclosure etc. complete as required.

1

-

-

... More
Office Table.

2

-

-

... More
Chairs

4

-

-

... More
Electrical Works with AC etc. as per specification & scope of work for SCADA Room

1

-

-

... More
Total for Bill No.-7 (SCADA Room) :

-

-

-

... More
Bill No.-8 Electrical & Instrumentation Works related to New TW & New OHSR :

-

-

-

... More
BoQ of LT Panel for New Tube well :

-

-

-

... More
Supply, Installation, Testing and Commissioning of the following Items complete in all respect and as per Scope of Work, Specification and as required at site:

-

-

-

... More
LT panel 50 HP Pump set :

-

-

-

... More
LT Panel 415 V indoor IP-42 compartmentalized 1.6 mm CRCA sheet for non load bearing 2 mm for load bearing member, front lockable hinged door, wall mountable, dust & vermin proof, epoxy coated, detachable gland plate, 100A TPN Al. bus-bar, SCADA compatible (sufficient interposing relays, 2NO+2NC Aux. contactors, potential free contacts etc. as required) complete with all accessories and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V 100 A TPN MCCB 35 KA with O/L, S/C & E/F protection, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 1 Set

-

-

-

... More
Outgoing:

-

-

-

... More
a) Automatic star-delta starter (50 HP pump set) with digital timer including O/C, S/C, O/V, U/V, SPP, E/F, lock rotor, phase reversal & dry run protection, On-Off-Trip indication lamp, start-stop push button, remote/local selector switch, suitable rated heavy duty capacitor with MCB & contactor for motor feeder only complete as required - 1 Set.

-

-

-

... More
b) 32 A SPN MCB - 2 No’s

-

-

-

... More
c) 10 A SPN MCB - 1 No for Chlorinator interlocked with starter (shall be ON only when pump set is ON). (d) RDOL Starter (1 HP) with MCB, Main & Aux. contactor, O/L relay, On-Off-Trip indication lamp, start-stop push button, remote/local selector switch complete as required - 1 Set

-

-

-

... More
LT panel 40 HP Pump set :

-

-

-

... More
LT Panel 415 V indoor IP-42 compartmentalized 1.6 mm CRCA sheet for non load bearing 2 mm for load bearing member, front lockable hinged door, wall mountable, dust & vermin proof, epoxy coated, detachable gland plate, 100A TPN Al. bus-bar, SCADA compatible (sufficient interposing relays, 2NO+2NC Aux. contactors, potential free contacts etc. as required) complete with all accessories and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V 100 A TPN MCCB 35 KA with O/L, S/C & E/F protection, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 1 Set

-

-

-

... More
Outgoing:

-

-

-

... More
a) Automatic star-delta starter (40 HP pump set) with digital timer including O/C, S/C, O/V, U/V, SPP, E/F, lock rotor, phase reversal & dry run protection, On-Off-Trip indication lamp, start-stop push button, remote/local selector switch, suitable rated heavy duty capacitor with MCB & contactor for motor feeder only complete as required - 1 Set.

-

-

-

... More
b) 32 A SPN MCB - 2 No’s

-

-

-

... More
c) 10 A SPN MCB - 1 No for Chlorinator interlocked with starter (shall be ON only when pump set is ON). (d) RDOL Starter (1 HP) with MCB, Main & Aux. contactor, O/L relay, On-Off-Trip indication lamp, start-stop push button, remote/local selector switch complete as required - 1 Set

-

-

-

... More
LT panel 30 HP Pump set :

-

-

-

... More
LT Panel 415 V indoor IP-42 compartmentalized 1.6 mm CRCA sheet for non load bearing 2 mm for load bearing member, front lockable hinged door, wall mountable, dust & vermin proof, epoxy coated, detachable gland plate, 100A TPN Al. bus-bar, SCADA compatible (sufficient interposing relays, 2NO+2NC Aux. contactors, potential free contacts etc. as required) complete with all accessories and as below:

-

-

-

... More
Incomer:

-

-

-

... More
415 V 100 A TPN MCCB 35 KA with O/L, S/C & E/F protection, digital multifunction meter, surge protection device, indication lamps for On-Off-Trip, R-Y-B complete as required - 1 Set

-

-

-

... More
Outgoing:

-

-

-

... More
a) Automatic star-delta starter (30 HP pump set) with digital timer including O/C, S/C, O/V, U/V, SPP, E/F, lock rotor, phase reversal & dry run protection, On-Off-Trip indication lamp, start-stop push button, remote/local selector switch, suitable rated heavy duty capacitor with MCB & contactor for motor feeder only complete as required - 1 Set.

-

-

-

... More
b) 32 A SPN MCB - 2 No’s

-

-

-

... More
c) 10 A SPN MCB - 1 No for Chlorinator interlocked with starter (shall be ON only when pump set is ON). (d) RDOL Starter (1 HP) with MCB, Main & Aux. contactor, O/L relay, On-Off-Trip indication lamp, start-stop push button, remote/local selector switch complete as required - 1 Set

-

-

-

... More
BoQ Other Electrical Item of Tube well for New Pump Set : (50 HP)

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
Supply and laying of XLPE insulated PVC sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade ( on surface) as per PWD General Specifications 2010 :

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 100 volts grade 50 sq.mm.(3.1/2 Core)

-

-

-

... More
Providing and fixing of 1.1 KV XLPE 3 core x 16 sq. mm (2 runs of 70 M for star-delta starter) cu. submersible flat cable up to submersible pump set including supply and laying of cable in GI conduit in floor. (Ref : RUIDP SOR 2017,51.5.6)

-

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with check nuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 3, 4 core size 16 sq. mm

-

-

-

... More
Gland for Aluminium cable 3½,4 core size 25-35 sq. mm

-

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 10 sq. mm - 16 sq. mm

-

-

-

... More
Aluminium cable core size 25 sq. mm - 35 sq. mm

-

-

-

... More
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES :

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked),1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked, recessed in wall etc. complete with powder coated/anodized concealed metal boxes required for having electronic fan regulators ( socket size),bell push, electronic buzzer,3 pin 6 Amp.,3 pin 16/20 Amp. Sockets and 6 Amp/16/20 Amp. Switches ( flush piano type accessories) etc. and covered with brown Bakelite white glazed translucent backside painted sheet 3 mm. thick etc. & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector(for Fan Box and Electronic Buzzer),PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases.:

-

-

-

... More
Wiring fan point with sheet metal fan box ( shape hexagonal ) in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade with step type electronic fan regulator 100 watts ( socket size)

-

-

-

... More
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 Sqm. 1100 volts grade.

-

-

-

... More
Wiring 3 pin 6 Amp. Wall socket point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sq.mm., 1100 volts grade.

-

-

-

... More
Wiring 3 pin 16/20 amp. Power plug control and switch.

-

-

-

... More
Supply and erection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing:

-

-

-

... More
PVC insulated copper conductor single core FR cable (ISI marked) overall 2.5 sq.mm.1100 volts grade.

-

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

-

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker double pole 40 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
P&F of IP20 LED batten type light fixture 18 W made from CRCA sheet housing suitable for mounting LED tube system (integral driver), Power consumption of 18W/36W, 1500/3000 lumens, system lumen efficiency 80 lm/watt output, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000 K, 4000 K and 6000 K.

-

-

-

... More
P/ F IP-65/ IP-66 protected street light luminaries 40 W on single piece pressure die cast aluminum housing with Diffuser / glass cover for ensuring IP-65 protection for output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance with GI bracket for exterior illumination complete as required.

-

-

-

... More
Providing and fixing of heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust Fan including making connections testing etc. as required (380 MM Sweep) (Ref : RUIDP SOR 2017,55.9.2)

-

-

-

... More
Safety items:

-

-

-

... More
Providing & fixing of shock treatment chart on wooden frame with 5 mm thick glass (Approx. Front Area 1.20 Sq. m.)

-

-

-

... More
Providing & fixing with bracket/supports etc. wall mounted Carbon Dioxide type fire extinguisher with Cylinder fully charge of 4.5 Kg capacity.

-

-

-

... More
Providing & fixing of First Aid Box Confirming to IS: 2217 - 1963.

-

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 – 1969.

-

-

-

... More
Providing of insulating hand gloves as Per Relevant IS Code.

-

-

-

... More
Providing & fixing of self-contained type LED emergency light with 2 Hrs. backup.

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc. where necessary including painting as per PWD General Specifications 2010 :

-

-

-

... More
G.I.EARTHING :

-

-

-

... More
Earthing of Sheet metal/iron clad Switches and metallic cases etc., with No.7/14 S.W.G. (7/2.18 mm. dia.) G.I. wire in 20 mm. dia. G.I. pipe partly recessed and partly on surface complete with 135 cm. long 50 mm. dia. G.I. earth pipe with G.I. reducing socket ( 50 mm.x 20 mm.) including erection of the same,10 metre below ground level with necessary charcoal & salt mixture etc. up to 13 metre in length ( including boring & refilling).

-

-

-

... More
BoQ Other Electrical Item of Tube well for New Pump Set : (40 & 30 HP)

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
Supply and laying of XLPE insulated PVC sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade ( on surface) as per PWD General Specifications 2010 :

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 100 volts grade 50 sq.mm.(3.1/2 Core)

-

-

-

... More
Providing and fixing of 1.1 KV XLPE 3 core x 16 sq. mm (2 runs of 70 M for star-delta starter) cu. submersible flat cable up to submersible pump set including supply and laying of cable in GI conduit in floor. (Ref : RUIDP SOR 2017,51.5.6)

-

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with check nuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 3, 4 core size 16 sq. mm

-

-

-

... More
Gland for Aluminium cable 3½,4 core size 25-35 sq. mm

-

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 10 sq. mm - 16 sq. mm

-

-

-

... More
Aluminium cable core size 25 sq. mm - 35 sq. mm

-

-

-

... More
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES :

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked),1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked, recessed in wall etc. complete with powder coated/anodized concealed metal boxes required for having electronic fan regulators ( socket size),bell push, electronic buzzer,3 pin 6 Amp.,3 pin 16/20 Amp. Sockets and 6 Amp/16/20 Amp. Switches ( flush piano type accessories) etc. and covered with brown Bakelite white glazed translucent backside painted sheet 3 mm. thick etc. & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector(for Fan Box and Electronic Buzzer),PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases.:

-

-

-

... More
Wiring fan point with sheet metal fan box ( shape hexagonal ) in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade with step type electronic fan regulator 100 watts ( socket size)

-

-

-

... More
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 Sqm. 1100 volts grade.

-

-

-

... More
Wiring 3 pin 6 Amp. Wall socket point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sq.mm., 1100 volts grade.

-

-

-

... More
Wiring 3 pin 16/20 amp. Power plug control and switch.

-

-

-

... More
Supply and erection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing:

-

-

-

... More
PVC insulated copper conductor single core FR cable (ISI marked) overall 2.5 sq.mm.1100 volts grade.

-

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

-

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker double pole 40 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
P&F of IP20 LED batten type light fixture 18 W made from CRCA sheet housing suitable for mounting LED tube system (integral driver), Power consumption of 18W/36W, 1500/3000 lumens, system lumen efficiency 80 lm/watt output, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000 K, 4000 K and 6000 K.

-

-

-

... More
P/ F IP-65/ IP-66 protected street light luminaries 40 W on single piece pressure die cast aluminum housing with Diffuser / glass cover for ensuring IP-65 protection for output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance with GI bracket for exterior illumination complete as required.

-

-

-

... More
Providing and fixing of heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust Fan including making connections testing etc. as required (380 MM Sweep)

-

-

-

... More
Safety items:

-

-

-

... More
Providing & fixing of shock treatment chart on wooden frame with 5 mm thick glass (Approx. Front Area 1.20 Sq. m.)

-

-

-

... More
Providing & fixing with bracket/supports etc. wall mounted Carbon Dioxide type fire extinguisher with Cylinder fully charge of 4.5 Kg capacity.

-

-

-

... More
Providing & fixing of First Aid Box Confirming to IS: 2217 - 1963.

-

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 – 1969.

-

-

-

... More
Providing of insulating hand gloves as Per Relevant IS Code.

-

-

-

... More
Providing & fixing of self-contained type LED emergency light with 2 Hrs. backup.

-

-

-

... More
Supply & erection of G.I. pipe for wiring purposes including bends, inspection boxes etc. where necessary including painting as per PWD General Specifications 2010 :

-

-

-

... More
G.I.EARTHING :

-

-

-

... More
Earthing of Sheet metal/iron clad Switches and metallic cases etc., with No.7/14 S.W.G. (7/2.18 mm. dia.) G.I. wire in 20 mm. dia. G.I. pipe partly recessed and partly on surface complete with 135 cm. long 50 mm. dia. G.I. earth pipe with G.I. reducing socket ( 50 mm.x 20 mm.) including erection of the same,10 metre below ground level with necessary charcoal & salt mixture etc. up to 13 metre in length ( including boring & refilling).

-

-

-

... More
Pressure Gauge for New Tube Well : (7 nos)

-

-

-

... More
Providing, installation, testing and commissioning of Glycerine filled Pressure Gauge of the following range with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer:

-

-

-

... More
0 to 4.0/0 to 6.0/0 to 10 Kg/cm2

-

-

-

... More
Total for Bill No.-8 : Electrical & Instrumentation Works related to New TW & New OHSR :

-

-

-

... More
Batala Water Supply DNIT : Sub Package : Pipeline

-

-

-

... More
Bill No.-9 Pumping Main :

-

-

-

... More
Excavation by mechanical means ( JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signals, providing and fixing caution boards crossing over trenches for access to the houses, watching fencing etc. and removal of surplus soil outside/inside the town involving lead up to 15 m. complete in all respects.

-

-

-

... More
Earthwork up to 1.50 m. Depth.

-

-

-

... More
All classes of soil except rocky

-

-

-

... More
Providing, Stringing out, cutting, jointing and testing of ISI marked DI pipe as per IS-8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage

-

-

-

... More
DI pipe as per IS 8329 DI-K9

-

-

-

... More
200mm i/d pipelines laid complete.

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.

-

-

-

... More
D.I. specials up to 300 mm.i/d.

-

-

-

... More
Providing & fixing C.I./D.I. Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1.6 as per ISI

-

-

-

... More
200 mm. i/d. Sluice Valves flanged.

-

-

-

... More
Providing & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS: 5312/2004 in pipe lines including jointing * cost of Nut Bolt, rubber insertion etc. complete.

-

-

-

... More
Class PN-1.0 as per ISI with gun metal flap.

-

-

-

... More
200 mm. i/d. Non-return valve.

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS: 14845 including jointing all carriages complete.

-

-

-

... More
C.I. Double air valve ( Size 100 mm)

-

-

-

... More
Jointing of D.I. Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. complete in all respect.

-

-

-

... More
100 mm. i/d. pipelines.

-

-

-

... More
200 mm. i/d. pipelines.

-

-

-

... More
Providing & fixing of rubber gasket/ring as per IS : 5382/1952 for DI/CI/pipes for making tyton jointing complete including cartage.

-

-

-

... More
100 mm. i/d. pipelines.

-

-

-

... More
200 mm. i/d. pipelines.

-

-

-

... More
Providing, Stringing out, Cutting, Jointing and Testing of ISI Marked DI Double Flanged Pipes with screwed flanged as per IS : 8329-2000, Class k-9 and laying the same in trenches to correct alignment and gradients ,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.

-

-

-

... More
200 mm. i/d pipe lines laid complete

-

-

-

... More
Total for Bill No.-9 : (Pumping Main)

-

-

-

... More
Bill No.-10 Distribution Main :

-

-

-

... More
Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in built up area where width of street / Lane from wall to wall is less than 3 Mtr including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site up to 15 meter distance complete in all respects.

-

-

-

... More
Earthwork up to 1.50 Mtr. Depth.

-

-

-

... More
All classes of soil except rocky

-

-

-

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil outside/inside the town involving lead up to 15 meter complete in all respect.

-

-

-

... More
Earthwork up to 1.50 mt. Depth.

-

-

-

... More
All classes of soil except rocky

-

-

-

... More
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage.

-

-

-

... More
DI pipe as per IS 8329 DI-K7

-

-

-

... More
100mmi/d. pipelines laid complete.

-

-

-

... More
150 mmi/d pipelines laid complete.

-

-

-

... More
200 mmi/d pipelines laid complete.

-

-

-

... More
Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.

-

-

-

... More
DI Specials : Up to 300 mm. i/d.

-

-

-

... More
Providing & fixing C.I./D.I. Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & Insertion sheet all carriage complete.(with the approval of Engineer-in-charge.)

-

-

-

... More
Class PN-1 as per ISI

-

-

-

... More
100 mm. i/d. Sluice Valves flanged.

-

-

-

... More
150 mm. i/d Sluice Valves flanged.

-

-

-

... More
200 mm. i/d Sluice Valves flanged.

-

-

-

... More
Providing & fixing double air valve ISI Marked as per IS: 14845 including jointing all carriages complete.

-

-

-

... More
C.I. Double air valve ( Size 100 mm)

-

-

-

... More
Providing & fixing Fire Hydrants with jointing including all carriages complete.( Without Fire hydrant surface box) size : 80 mm. complete in all respect.

-

-

-

... More
CI fire Hydrants S.V.Type IS-909

-

-

-

... More
Masonry Sluice Valve Chamber :

-

-

-

... More
Construction of masonry Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size 0.6 x 0.6 m.

-

-

-

... More
Size 0.9 x 0.9 mtr

-

-

-

... More
Providing & Fixing C.I. indicating plates of size 100 mm.*100 mm.for SV/FH including synthetic enamel paint & letters in white enamel paint fixing in the ground with angle iron of size 25*25*5 mm.,230 mm.height from ground including concrete block complete in all respect as directed by Engineer-in-charge.

-

-

-

... More
Jointing of D.I. Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc. complete in all respect.

-

-

-

... More
100mmi/d

-

-

-

... More
150 mmi/d

-

-

-

... More
200mm i/d

-

-

-

... More
Providing & fixing of rubber gasket/ring as per IS : 5382/1952 for DI/CI/pipes for making tyton jointing complete including cartage.

-

-

-

... More
100mmi/d

-

-

-

... More
150 mmi/d

-

-

-

... More
200mm i/d

-

-

-

... More
Total for Bill No.-10 : (Distribution Main)

-

-

-

... More
Bill No.-11 Providing/laying of GI 50 mm i/d :

-

-

-

... More
Providing and laying,jointing,fixing and testing ISI marked G.I.Pipe (as per IS :1239) B-Class premium make such as (Jindal,Hissar) including cost of Specials such as tees,bends,sockets,elbow,clamps etc.cutting,threading and testing in the trenches in the ground complete.

-

-

-

... More
50mmi/d.

-

-

-

... More
Providing and fixing MS flange with Rubber Insertion and Nut Bolts complete in all respects.

-

-

-

... More
50 mm.i/d.

-

-

-

... More
Total for Bill No.-11 : (Providing & laying of GI 50 mm.i/d.)

-

-

-

... More
Bill No.-12 House Service Connection : (Only Water Meter)

-

-

-

... More
Providing, fixing & jointing Muti Jet Water Meter of approved make as per IS:779/94 in G.I. pipe line including cutting and threading pipe including cost of water meter but excluding cost of specials in all respect complete.

-

-

-

... More
15 mm size

-

-

-

... More
Total for Bill No.-12 : (HSC (Only Water Meter))

-

-

-

... More
Bill No.-13 House Service Connection :

-

-

-

... More
Earthwork Excavation :

-

-

-

... More
Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in built-up area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site up to 15 meter distance complete in all respects.

-

-

-

... More
Earth work up to 1.5 m Depth

-

-

-

... More
All classes of soil except rocky

-

-

-

... More
Providing and Fixing Service Saddle :

-

-

-

... More
Clamp saddles should be Non corrosive Engineering Plastic body moulded with Stainless steel threaded metal insert for tapping outlet. Clamp saddles for service connection from water distribution mains shall be of wrap around design, wide skirt and wide straps support, which shall reinforce the pipe while providing excellent stability to the saddle. Clamp Saddles for service connections shall be of fastened strap type with threaded (as per IS:554) female outlet of Stainless steel for service connection. The design of the saddle body should be such that, the service connection outlet metal insert shall project out towards pipe side and align with the hole drilled on the pipe to ensure positive locking against rocking or creeping on the pipe, as might be caused by vibration, pressure or excessive external loading. Saddle Seal shall be of virgin rubber SBR Grade 30 / NBR (NSF 61 approved). It shall be of type pressure activated hydro-mechanical design. It shall be contoured gasket to provide a positive initial seal which increases with increase in the line pressure. Saddle straps shall be made of plastic with or without metal reinforcement depending on size and injection moulded to prevent galvanic corrosion over the long service life. In case of metal reinforcement, the metal should not come in direct contact with pipe. Fasteners details: Stainless Steel Type 202, NC rolled thread, Tightening torque for ½” (M12) Fastener: 14-15 kg.m and for 5/8” (M 16) Fastener: 21-23 kg.m

-

-

-

... More
80 mm-100 mm.

-

-

-

... More
15 mm. connection

-

-

-

... More
Providing and fixing GM Ferrule :

-

-

-

... More
Providing ISI Marked G.M ferrule as per IS:2692, drilling and tapping cast iron pipe lines of all diameters and screwing in Ferrule and connections complete in all respect.

-

-

-

... More
15 mm i/d Ferrule Medium

-

-

-

... More
Providing and fixing Female Thread Adaptors :

-

-

-

... More
PP Compression Metal Insert Female Thread Adaptors as specified in the drawing with SS304 material with BSP Threads as per ISO 14236 standard. Body, Nut / Cap –Polypropylene, Clip Ring-POM (Acetylic resin ),Packing bush- Polypropylene, “O” ring – NBR. Pressure rating will be PN 16.The Compression fittings for intended for conveyance of Potable water for Human consumption to be tested to comply with BS 6920 specifications in any of the laboratories like DVGM / KIWA / SPGN / WRc –NSF and certificate of compliance to be produced for the following parameters.

-

-

-

... More
15 mm. connection

-

-

-

... More
Providing and fixing Double Compression Elbow :

-

-

-

... More
Double Compression Elbow with Body, Nut / Cap – Polypropylene, Clip Ring-POM (Acetylic resin ),Packing bush- Polypropylene, “O” ring – NBR. Pressure rating will be PN 16. The Compression fittings for intended for conveyance of Potable water for Human consumption to be tested to comply with BS 6920 specifications in any of the laboratories like DVGM / KIWA / SPGN / WRc – NSF and certificate of compliance to be produced for the following parameters.

-

-

-

... More
15 mm. connection

-

-

-

... More
Providing and fixing MDPE PE 80 Blue Pipe PN 16 :

-

-

-

... More
MDPE PE 80 Blue Pipe PN 16 for 15mm & PN 12.5 for 25mm and 32mm

-

-

-

... More
15 mm connection

-

-

-

... More
Providing and fixing UPVC Ball Valve :

-

-

-

... More
UPVC Ball Valves, with compression- female threaded 20mm with Body, Nut / Cap –Polypropylene, Clip Ring-POM (Acetylic resin ),Packing bush- Polypropylene, “O” ring – NBR. Pressure rating will be PN 16.The Compression fittings for intended for conveyance of Potable water for Human consumption to be tested to comply with BS 6920 specifications in any of the laboratories like DVGM / KIWA / SPGN / WRc –NSF and certificate of compliance to be produced for the following parameters.

-

-

-

... More
15 mm connection

-

-

-

... More
Multi Jet Meter

-

-

-

... More
Providing, fixing & jointing multi-jet water meter of approved make as per IS: 779/94 in G.I.pipe line including cutting and threading pipe, including cost of water meter but excluding cost of specials complete in all respect.

-

-

-

... More
15 mm size

-

-

-

... More
Total for Bill No.-13 : (HSC (Only Water Meter))

-

-

-

... More
Bill No.-14 Dismantle and Road Restoration Work :

-

-

-

... More
Dismantling of Bituminuos courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications

-

-

-

... More
Dismantling of Granular courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications

-

-

-

... More
Dismantling concrete or precast concrete-

-

-

-

... More
cement concrete plain 1:2:4

-

-

-

... More
Dismantling brick work tile masonry or tile lining.

-

-

-

... More
Dismantling Dry brick work :

-

-

-

... More
Earth work excavation in ordinary soil exclusive of compensation of earth

-

-

-

... More
Kassi work undressed

-

-

-

... More
Cement concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type.

-

-

-

... More
Extra for using batch type concrete mixer as per IS : 1791 where not included in the rates.

-

-

-

... More
At through Rate

-

-

-

... More
Dry brick on edge paving sand grouted over 50 mm. thick rammed brick aggregate 40 mm.gauge.

-

-

-

... More
At through Rate

-

-

-

... More
Compacting original ground below embankment- Loosening, levelling and compacting original ground below embankment to facilitate placement of first layer of embankment t facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per technical clause305 of MORT & H specifications.

-

-

-

... More
Water Bound Macadam Grading II (Without Screening for low volume Roads/ undesigned roads).Providing, laying, spreading and compacting stone aggregates of grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
Water Bound Macadam Grading III (Without Screening for low volume Roads/ undesigned roads).Providing, laying, spreading and compacting stone aggregates of grading III to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications.

-

-

-

... More
At 100% Labour Rate

-

-

-

... More
Tack coat @ 0.40 Kg per Sqm.

-

-

-

... More
Providing and applying Tack Coat : with penetration grade bitumen VG 10 using bitumen pressure distributor at the rate of 0.40 kg/Sqm on the prepared surface/granular surface treated with primer coats per technical clause 503 of MORT&H specifications.

-

-

-

... More
Providing, laying surface dressing in single coat using crushed stone aggregate size on a layer of bituminuos binder VG-10 @1 kg/Sqm laid on prepared surface complete as per CSR item.

-

-

-

... More
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batch type hot mix plant with bituminous binder VG-30 @ 1.46 kg per Sqm, and laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 511 of MORT&H specifications.

-

-

-

... More
Seal coat type B :

-

-

-

... More
Providing and laying of premix sand seal coat premix in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-30 @ 0.68 kg/Sqm laid to the specified levels ,grade and cross fall complete as per technical clause 513 of MORT& H specifications.

-

-

-

... More
Road Restoration : Sewerage Network

-

-

-

... More
Sub Head No.-1 Cement Concrete Road

-

-

-

... More
Earth work excavation in ordinary soil exclusive of compensation of earth:-

-

-

-

... More
Kassi work undresses involving an average horizontal throw up to 2.0 m and an average vertical lift up to 0.5 m including Breaking of clods.

15726

-

-

... More
Cement concrete 1:8:16 with 40 mm gauge stone aggregate

3145.2

-

-

... More
using concrete mixer volumetric type

-

-

-

... More
Cement Concrete 1:2:4 with stone ballast or shingle

3145.2

-

-

... More
using concrete mixer volumetric type

-

-

-

... More
Sub Head No.-2 Dry Brick on edge Road

-

-

-

... More
Dry brick on edge paving sand grouted over 50 mm thick rammed brick aggregate 40 mm gauge

41937

-

-

... More
Sub Head No.-3 Inter locking Paver Blocks

-

-

-

... More
Providing and laying 60 mm thickcement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish by strong vibratory process or with vibro hydraulic compaction machine and of approved size and design/ shape laid in ordinary grey colour and oattern over and including 40 mm thick compacted bed of coarse sand filling the joints with fine sand etc.all complete as per direction of Engineer - in charge for light traffic areas such as padestrain plazas, shopping complexes, ramps,car parks,office drive ways, housing colonies, office complexes, rural roads with low volume traffic,farm houses,beach sites, tourist resorts, local authority footways, residential roade etc.

26211

-

-

... More
Cement concrete 1:8:16 with 40 mm gauge stone aggregate

2621.1

-

-

... More
using concrete mixer volumetric type

-

-

-

... More
Sub Head -4 Bituminous Road

-

-

-

... More
Granular sub base ( Close Graded material Grading -1)

-

-

-

... More
Construction of granular sub base by ptoviding close graded material grading-1 spreading in uniform layers with motor grader or prpared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications.

-

-

-

... More
Providing two layer

32501.1

-

-

... More
Water Bound Macadam Grading II

-

-

-

... More
Water Bound Macadam Grading II without screening for low volume road/undesigrared roads Providing, Laying, spreadingand compacting stone aggregates of gradingII to water bound macadam specification including sprreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to propoer grade and camber, applying and brooming requisite type of screening/ bindinng material to fillup the interstices of coarse aggregate, watering and compacting to the rquired density complete as per technicalclause 404 of MORT&H specifications.

12150

-

-

... More
Water Bound Macadam Grading III

-

-

-

... More
Water Bound Macadam Grading iii(ithout screening for low volume road/undesigrared roads )Providing, Laying, spreadingand compacting stone aggregates of grading III to water bound macadam specification including sprreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to propoer grade and camber, applying and brooming requisite type of bindinng material to fillup the interstices of coarse aggregate, watering and compacting to the rquired density complete as per technicalclause 404 of MORT&H specifications.(A&C-2)

-

-

-

... More
Wet Mix Macadam

-

-

-

... More
Providing , Laying, Spreading and compacting grded stone aggregate to wet mix macadam specifications including premixing the material with water at OMC in mechanical mix plant laying in uniform layerswith paver in sub base/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications.

101.1

-

-

... More
Providing two layers

-

-

-

... More
Prime coat @ 0.85 kg per sqm.

-

-

-

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 kg/sqm complete as per technical clause 502 of MORT&H specifications.

162505.5

-

-

... More
Tack Coat@ 0.40 kg per sqm.

-

-

-

... More
Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared btuminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications.

162505.5

-

-

... More
Open -Graded Premix Sufacing 20 mm thickness

-

-

-

... More
Providing , Laying and compaction of open grade premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a batchtype hot mix plantwith bitminous bindr VG-30 (w,-.e.f. 1 02 2016 letter no 9070-9145dt 08.02.2016)@ 1.46 kg per sqm, laid with paver and rolling with a smooth wheeled roller 8-10 tonne capacity , finished to ruired level and grades complete as per technical Claue511 of MORT&H specifications

162000

-

-

... More
Bituminous Macadam 50 mm to 75 mm thickness (Grading -II)

-

-

-

... More
Providing and Laying bituminous macadam 50 mm to 75 mm thick with batch type hot mix plant using crushed aggregates of specified grading premixed with bituminous binder VG-10 @3.4% laid over a previously prepared surface with paver finisher to the rquired grade, level and alignment and rolled to achievethe desired compaction complete as per technical clause 504 of MORT&H specifications

37.91

-

-

... More
Semi-Dense Bituminous Concrete 25 mm to 30.mm thickness ( Grading II)

-

-

-

... More
Providing and laying semi dense bituminous concrete concrete 25 mm to 30 mm thick batch type HMP using croshed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5%

15.165

-

-

... More
Seal Coat Type B

-

-

-

... More
Providing and Laying of premix sand seal coat premixed in batch type hot mix plant using specified fine aggregates and penetration grade bitumen VG-1 @ 0.68 kg per sqm laid to the specified levels grade and cross fall complete as per technical clause 513of MORT&H specifications

162505.5

-

-

... More
Total for Bill No.-14 : (Dismantle & Road Restoration)

-

-

-

... More
Batala Water Supply DNIT : Sub Package : OHSR

-

-

-

... More
Bill No.-15 Construction of OHSR with Pile foundation : (0.5 lakh gal. capacity and 25.91 mt. Staging.)

-

-

-

... More
Design, Drawing and Construction of 50,000 Gallon Capacity of Circular RCC Tank Staging Height of 25.91 Mtr Including All RCC Structures Like Raft/Pile Foundation, Columns, Brace beams Ring Beam Bottom/Top Dome, Vertical Wall, SS Railing as per drawing In Staircase, in Staircase Landing around the cone wall and top dome. With P & F of 4 No’s Vertical DI Flange Pipe Puddle Collars,Bell Mouth,Duck Foot Bend,Expansion joint,MS Clamps with suitable Sluice Valve and Valve Chamber, Internal Stair, Lettering & Painting of OHSR & Railing. Plinth Protection, Earthling Pit, Lighting Arrestor, Stair Case Door With Locking Arrangement, Water Level Indicator etc as per Design and Drawing / Specification all respect complete.

1

-

-

... More
Total for Bill No.-15 : Construction of OHSR-0.5 lakh gal.cap. (1 no)

-

-

-

... More
Bill No.-16 Construction of OHSR with Pile/Raft foundation :(2 lakh gal. capacity and 25.91 mts. Staging.)

-

-

-

... More
Design, Drawing and Construction of 200,000 Gallon Capacity of Circular RCC Tank Staging Height of 25.91Mtr Including All RCC Structures Like Raft/Pile Foundation, Columns, Brace beams Ring Beam Bottom/Top Dome, Vertical Wall, SS Railing as per drawing In Staircase, in Staircase Landing around the cone wall and top dome. With P & F of 4 Nos Vertical DI Flange Pipe,Puddle Collars,Bell Mouth,Duck Foot Bend,Expansion joint,MS Clamps with suitable Sluice Valve and Valve Chamber, Internal Stair, Lettering & Painting of OHSR & Railing. Plinth Protection, Earthling Pit, Lighting Arrestor, Stair Case Door With Locking Arrangement, Water Level Indicator etc as per Design and Drawing / Specification all respect complete.

1

-

-

... More
Total for Bill No.-16 : Construction of OHSR-2 lakh gal.cap. (1 no)

-

-

-

... More
Bill No.-17 Dismantle of OHSR :

-

-

-

... More
Dismantling concrete or precast concrete-

-

-

-

... More
Reinforced Cement Concrete

-

-

-

... More
Dismantling flanged Joints for Cast Iron Pipes,Valves and Specials including ride back of bolts,Nuts and washers to the Engineer-in-charge.

-

-

-

... More
Labour Rate :

-

-

-

... More
125 mm.,150 mm.,175 mm.,200 mm.,225 mm. and 250 mm.internal diameter of pipe,valves or special.

-

-

-

... More
300 mm.,350 mm. and 375 mm.internal diameter of pipe,valves or special.

-

-

-

... More
Valves

-

-

-

... More
Providing and fixing double scaffolding system ( cup lock type) on the exterior side of building/structure,up to 25 metre height,above ground level,including additional rows of scaffolding in stepped manner as per requirement of site,made with 40 mm.dia. M.S. tube,placed 1.5 metre centre to centre,horizontal & vertical tubes joint with cup & lock system with M.S. tube challis,M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and /or applying chemical and removing it thereafter.The scaffolding system shall be stiffened with bracings,runners,connecting with the building etc. wherever required,if feasible for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. (Ref : CPWD 2014/Code no.25.2)

-

-

-

... More
The elevation area of the scaffolding shall be measured for payment purpose.

-

-

-

... More
The payment will be made once only for execution of all items for such works.

-

-

-

... More
Total for Bill No.-17 : Dismantle of OHSR

-

-

-

... More
Bill No.-18 BoQ of Electrical of New OHSR :

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
Supply and laying of (UNDERGROUND) aluminium conductor XLPE/PVC insulated PVC sheathed aluminium conductor armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 6 sq.mm. (Three Core)

-

-

-

... More
Supply & laying of aluminium conductor XLPE/P.V.C. insulated armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specifications, 2010:

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 6 sq.mm. (Twin Core)

-

-

-

... More
Supply and laying of XLPE/PVC insulated PVC sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade ( on surface) as per PWD General Specifications 2010 :

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 4 sq.mm. (Three Core)

-

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 4 core size 6 sq. mm

-

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq. mm - 6 sq. mm

-

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

-

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker double pole 6 to 32 A amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
P/ F IP-65/ IP-66 protected street light luminaries 40 W on single piece pressure die cast aluminum housing with Diffuser / glass cover for ensuring IP-65 protection for output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance with GI bracket for exterior illumination complete as required.

-

-

-

... More
Supply & errection of G.I.pipe for wiring purposes including bends,insepection boxes etc. where necessary including painting as per PWD General Specifications 2010 :

-

-

-

... More
G.I.EARTHING :

-

-

-

... More
Earthing of Sheet metal/iron clad Switches and metallic cases etc.,with No.7/14 S.W.G. (7/2.18 mm.dia.) G.I. wire in 20 mm.dia. G.I.pipe partly recessed and partly on surface complete with 135 cm. long 50 mm.dia. G.I. earth pipe with G.I. reducing socket ( 50 mm.x 20 mm.) including erection of the same,10 metre below ground level with necessary charcoal & salt mixture etc. up to 13 metre in length ( including boring & refilling).

-

-

-

... More
Total for Bill No.-18 : BoQ of Electrical of New OHSR :

-

-

-

... More
Bill No.-19 BoQ of Electrical of OHSR Without lightning Arrestor with Aviation Light :

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
Supply and laying of (UNDERGROUND) aluminium conductor XLPE/PVC insulated PVC sheathed aluminium conductor armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 6 sq.mm. (Three Core)

-

-

-

... More
Supply & laying of aluminium conductor XLPE/P.V.C. insulated armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specifications, 2010:

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 6 sq.mm. (Twin Core)

-

-

-

... More
Supply and laying of XLPE/PVC insulated PVC sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade ( on surface) as per PWD General Specifications 2010 :

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 4 sq.mm. (Three Core)

-

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 4 core size 6 sq. mm

-

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq. mm - 6 sq. mm

-

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

-

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker double pole 6 to 32 A amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
P/ F IP-65/ IP-66 protected street light luminaries 40 W on single piece pressure die cast aluminum housing with Diffuser / glass cover for ensuring IP-65 protection for output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance with GI bracket for exterior illumination complete as required.

-

-

-

... More
Supply & errection of G.I.pipe for wiring purposes including bends,insepection boxes etc. where necessary including painting as per PWD General Specifications 2010 :

-

-

-

... More
G.I.EARTHING :

-

-

-

... More
Earthing of Sheet metal/iron clad Switches and metallic cases etc. With No.7/14 S.W.G. (7/2.18 mm.dia.) G.I. wire in 20 mm.dia. G.I.pipe partly recessed and partly on surface complete with 135 cm. long 50 mm.dia. G.I. earth pipe with G.I. reducing socket ( 50 mm.x 20 mm.) including erection of the same,10 metre below ground level with necessary charcoal & salt mixture etc. up to 13 metre in length ( including boring & refilling).

-

-

-

... More
Providing and fixing of aviation obstruction light luminaire comprising of yellow painted die cast aluminium alloy housing, red coloured polycarbonate dome, LED lamp complete in all respect. (Ref : RUIDP SOR 2017,58.24)

-

-

-

... More
Total for Bill No.19 : BoQ of Electrical of OHSR Without lightning Arrestor with Aviation Light :

-

-

-

... More
Bill No.-20 BoQ of Electrical of OHSR With lightning Arrestor & Aviation Light :

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
Supply and laying of (UNDERGROUND) aluminium conductor XLPE/PVC insulated PVC sheathed aluminium conductor armoured and served cable to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications 2010:

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 6 sq.mm. (Three Core)

-

-

-

... More
Supply & laying of aluminium conductor XLPE/P.V.C. insulated armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specifications, 2010:

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 6 sq.mm. (Twin Core)

-

-

-

... More
Supply and laying of XLPE/PVC insulated PVC sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade ( on surface) as per PWD General Specifications 2010 :

-

-

-

... More
Aluminium conductor XLPE/PVC insulated PVC sheathed armoured and served cable working voltage 100 volts grade 4 sq.mm. (Three Core)

-

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 4 core size 6 sq. mm

-

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 4 sq. mm - 6 sq. mm

-

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

-

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker double pole 6 to 32 A amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
P/ F IP-65/ IP-66 protected street light luminaries 40 W on single piece pressure die cast aluminum housing with Diffuser / glass cover for ensuring IP-65 protection for output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance with GI bracket for exterior illumination complete as required.

-

-

-

... More
Lightning Conductor:

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc. complete as required. (Ref :(6.2 DSR (E&M) 2016)

-

-

-

... More
Providing and fixing of GI tape 20x3 mm thick on parapet or on surface of wall for lightning conductor complete as required (for horizontal run) (Ref :(6.7 DSR (E&M) 2016)

-

-

-

... More
Providing and fixing of GI tape 20x3 mm thick on parapet or on surface of wall for lightning conductor complete as required (for vertical run) (Ref : (6.8 DSR (E&M) 2016)

-

-

-

... More
Providing and fixing of testing joint, made of 20x3 mm thick GI strip, 125 mm long with 4 No's of GI bolts, nuts, chuck nuts and spring washers etc. complete as required. (Ref :(6.12 DSR (E&M) 2016)

-

-

-

... More
Providing and laying of GI tape 32x6 mm from earth electrode directly in ground as required. (Ref : (6.14 DSR (E&M) 2016)

-

-

-

... More
Supply & errection of G.I.pipe for wiring purposes including bends,insepection boxes etc. where necessary including painting as per PWD General Specifications 2010 :

-

-

-

... More
G.I.EARTHING :

-

-

-

... More
Earthing of Sheet metal/iron clad Switches and metallic cases etc. With No.7/14 S.W.G. (7/2.18 mm.dia.) G.I. wire in 20 mm.dia. G.I.pipe partly recessed and partly on surface complete with 135 cm. long 50 mm.dia. G.I. earth pipe with G.I. reducing socket ( 50 mm's 20 mm.) including erection of the same,10 metre below ground level with necessary charcoal & salt mixture etc. up to 13 metre in length ( including boring & refilling).

-

-

-

... More
Providing and fixing of aviation obstruction light luminaire comprising of yellow painted die cast aluminium alloy housing, red coloured polycarbonate dome, LED lamp complete in all respect. (Ref : RUIDP SOR 2017,58.24)

-

-

-

... More
Total for Bill No.-20 : BoQ of Electrical of OHSR With lightning Arrestor & Aviation Light :

-

-

-

... More
Bill No.-21 BoQ of Electrical of Tube Well for Existing Pump Set :

-

-

-

... More
Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site:

-

-

-

... More
Supply and laying of XLPE insulated PVC sheathed aluminium conductor armoured cable working voltage up to and including 1100 volts grade ( on surface) as per PWD General Specifications 2010 :

-

-

-

... More
Aluminium conductor XLPE insulated PVC sheathed armoured and served cable working voltage 100 volts grade 50 sq.mm.(3.1/2 Core)

-

-

-

... More
S/E of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.

-

-

-

... More
Gland for Aluminium cable 3½,4 core size 25-35 sq. mm

-

-

-

... More
S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely.

-

-

-

... More
Aluminium cable core size 25 sq. mm - 35 sq. mm

-

-

-

... More
Supply & errection of G.I.pipe for wiring purposes including bends,insepection boxes etc. where necessary including painting as per PWD General Specifications 2010 :

-

-

-

... More
G.I.EARTHING :

-

-

-

... More
Earthing of Sheet metal/iron clad Switches and metallic cases etc.,with No.7/14 S.W.G. (7/2.18 mm.dia.) G.I. wire in 20 mm.dia. G.I.pipe partly recessed and partly on surface complete with 135 cm. long 50 mm.dia. G.I. earth pipe with G.I. reducing socket ( 50 mm.x 20 mm.) including erection of the same,10 metre below ground level with necessary charcoal & salt mixture etc. up to 13 metre in length ( including boring & refilling).

-

-

-

... More
SURFACE CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES :

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked),1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked installed on surface etc. Complete with uPVC boxes (on surface) required for suitable number of modules, for having electronic fan regulators ( two module), bell push, electronic buzzer,3 pin 6 Amp.,3 pin 16/20 Amp. Sockets and 6 Amp/16/20 Amp. Switches ( flush piano type accessories) etc. and covered with Frame Plate etc., & including the cost of required number of modular switches/sockets, step type electronic fan regulator 100 watts,PVC connector(for Fan Box and Electronic Buzzer), PVC Bush,Steel Hooks,Circular Inspection Box (Surface Type) conduit pipe & copper wire and other petty material etc. including the cost of painting as required:

-

-

-

... More
Wiring fan point without fan box in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade with step type electrnoic fan regulator 100 watts ( two module)

-

-

-

... More
Wiring light point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 Sqm. 1100 volts grade.

-

-

-

... More
Wiring 3 pin 6 Amp. Wall socket (shuttered) point in PVC insulated copper conductor single core FR cable ( ISI marked) overall 1.5 sq.mm.1100 volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FR cable ( ISI marked) overall 1 sq.mm., 1100 volts grade.

-

-

-

... More
Wiring 3 pin 16/20 amp. Power plug control (Shuttered) and switch.

-

-

-

... More
Supply and errection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing.:

-

-

-

... More
PVC insulated copper conductor single core FR cable ( ISI marked) overall 2.5 sq.mm.1100 volts grade.

-

-

-

... More
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard/Mini Guard), Legerand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA) (Hager Vision+)

-

-

-

... More
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/RCBO/RCCB's 8 way each

-

-

-

... More
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.

-

-

-

... More
GROUP-A: (Siemens(Beta Guard), Legerand (Lexic) & Schneider (Neo Break), L&T (EXORA) (Hager)

-

-

-

... More
Miniature circuit breaker double pole 40 amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply

-

-

-

... More
P&F of IP20 LED batten type light fixture 18 W made from CRCA sheet housing suitable for mounting LED tube system (integral driver), Power consumption of 18W/36W, 1500/3000 lumens, system lumen efficiency 80 lm/watt output, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000 K, 4000 K and 6000 K.

-

-

-

... More
P/ F IP-65/ IP-66 protected street light luminaries 40 W on single piece pressure die cast aluminum housing with Diffuser / glass cover for ensuring IP-65 protection for output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance with GI bracket for exterior illumination complete as required.

-

-

-

... More
Providing and fixing of heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust Fan including making connections testing etc. as required (380 MM Sweep)

-

-

-

... More
Safety items:

-

-

-

... More
Providing & fixing of shock treatment chart on wooden frame with 5 mm thick glass (Approx. Front Area 1.20 Sq. m.)

-

-

-

... More
Providing & fixing with bracket/supports etc. wall mounted Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5 Kg capacity.

-

-

-

... More
Providing & fixing of First Aid Box Confirming to IS : 2217 - 1963.

-

-

-

... More
Providing of insulating rubber mat 1 M wide 12 mm thick for LT Panel to Withstand 15KV Dielectric Strength As Per IS : 5424 - 1969

-

-

-

... More
Providing of insulating hand gloves as Per Relevant IS Code

-

-

-

... More
Providing & fixing of self contained type LED emergency light with 2 Hrs. backup.

-

-

-

... More
Total for Bill No.-21 : BoQ of Electrical of Tube Well for Existing Pump Set :

-

-

-

... More
Batala Sewerage Network System

-

-

-

... More
Bill No.-22: Dismantling of Roads

-

-

-

... More
Dismantling of bituminous courses of flexible pavements by mechanical means and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT&H specifications

2148.12

-

-

... More
Dismantling of granular courses of flxible pavements by manual means and disposal of dismantled materials upto a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT& H specifications

13426

-

-

... More
Dismantling concrete or precast concrete

-

-

-

... More
Cement concrete plain 1:2:4

1649

-

-

... More
Lime concrete, cement concrete 1:6:12 or leaner

5600.5070000000005

-

-

... More
Dismantling brick or flagged stone flooring without concrete base

27971.2

-

-

... More
Total for Bill No.22

-

-

-

... More
Bill No.-23 Lateral and Trunk Sewer

-

-

-

... More
Excavation mannually in trenches with straight or open cutting in a built up street / lanes having wall to wall width upto 3 metre for sewers and manholes to full depths as shown in drwaings, including shoring, dressing to correct sections and dewatering of rain water provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, ,fixing and maintenance of caution boards,fencing, refilling trenches, watering , dressing and restoration of surface to orignal level and removal of surplus spoils from the site of works up to 15 metre,for all works other than connections to complete in all respects. Where wall to wall width is upto 3.0 Mtr. where as in open area or built up street/lane having wall to wall width more than 3.0 Mtr, excavation will be done by mechnical means. In case of unavodidable circumstances, if, manual excavation is required other than the specified above, Superintending Engineer is competent to permit after his personal satisfaction subject to prior approval on the record. If prior approval is not accoded for manual excavation then contractor will be paid as excavation by mech. means and the contractor will have no claim for that.

-

-

-

... More
For Depth not exceeding 2.0 m B.G.L

-

-

-

... More
For all clases of soil except rocky

29801

-

-

... More
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewer and manhole to full depths as shwn in drawing,including dressing to correct sections and dewatering ,provision for diversion traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods,watching,etc.,,fixing and maintenance of caution boards,fencing refilling trenches, watering , ramming and restoration of surface to orignal level and removal of surplus spoils from the site of works up to one chain (15 m) complete in all respects.

-

-

-

... More
For depth not exceeding 3 m. B.G.L

-

-

-

... More
For all classes of soil except rocky

221071

-

-

... More
For depth exceeding 3.0 m. but not exceeding 4.50 m. B.G.L

-

-

-

... More
For all classes of soil except rocky

39623.45

-

-

... More
For depth exceeding 4.50 m. but not exceeding 6.0 m. B.G.L

-

-

-

... More
For all classes of soil except rocky

4495

-

-

... More
For depth exceeding 6.0 m. but not exceeding 7.5 m. B.G.L

-

-

-

... More
For all classes of soil except rocky

132.35

-

-

... More
Providing and fixing timbering on face of trenches if required for sewers and manholes for item 29.4 and 29.5 irrespective of the depth,measuring Each timbered surfaces of trench on which timbering is done.

-

-

-

... More
Type-I,Simple form of timbering.

-

-

-

... More
For trench having width up to 1.0 metre.

51713

-

-

... More
For trench having width above 1.0 metre & up to 2.0 metre.

107752

-

-

... More
For trench having width above 2.0 metre & up to 3.0 metre.

64897

-

-

... More
Pipe Material

-

-

-

... More
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.

-

-

-

... More
Class SN-8

-

-

-

... More
160 mm O/D

30525

-

-

... More
200 mm O/D

84144

-

-

... More
250 mm O/D

8906

-

-

... More
315 mm O/D

13591

-

-

... More
Providing, lowering in trenches to correct gradient and alignments, jointing with tytone rubber joint and cutting of RCC S/S pipes having inside HDPE. lining ISI marekd as per ISI code IS:458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc.,cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and to ensure this, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer incharge including all cartage etc copmplete in all respects.

-

-

-

... More
RCC pipes with inside HDPE lining class - NP-3

-

-

-

... More
400 mm i/d.

10679

-

-

... More
600 mm i/d.

4947

-

-

... More
800 mm i/d.

6117

-

-

... More
1000 mm i/d.

1037

-

-

... More
1400 mm i/d.

1049

-

-

... More
1600 mm i/d.

2414

-

-

... More
Extra for providing 1:2 cement sand mortar on tytone rubber joint of RCC pipes having sockets extended out of barrel, in trenches including facing trowelling and finishing the joints at the angle of 45 degree with faces of socket keeping joints wet till cured, testing the pipe joints for leak-proof and making good all leakage and defects as per specifications.

-

-

-

... More
NP-3 & NP-4 Pipes S/S joints having internal dia meter of pipe:-

-

-

-

... More
400 mm internal diameter

4272

-

-

... More
600 mm internal diameter

1979

-

-

... More
800 mm internal diameter

2447

-

-

... More
1000 mm internal diameter

415

-

-

... More
1400 mm internal diameter

420

-

-

... More
1600 mm internal diameter

966

-

-

... More
Cement Concrete 1:2:4 with stone ballast or Shingle using concrete mixer volumetric type.

1239.65

-

-

... More
Extra for making connections of all sizes newly laid sewers within benching of fully charged sewers including pluging of sewer, dewatering & desilting of manholes etc. complete in all respects.

-

-

-

... More
with existing sewer of 300 mm id and below

35

-

-

... More
With existing sewer above 300 mm id up to 700 mm id

5

-

-

... More
With existing sewer 700 mm id and above

8

-

-

... More
Pipe Bedding

-

-

-

... More
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.

27220.9

-

-

... More
Providing and Erection of cast RCC ventilating column having minimum 200 mm internal diametre including excavation, bases columns, caps, cowls or wire domes, etc. complete including carriage from the stores of the Engineer-In-Charge of works, to sites of works, loading and unloading fixing and jointing and setting the same in position complete in all respects.

-

-

-

... More
9.1m Height Including cost of ventillation shaft

26

-

-

... More
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.

-

-

-

... More
Class SN-8

-

-

-

... More
160 mm O/D

156

-

-

... More
Extra for Disposal of Surplus Spoils/Earth if any beyond 15 Mtr. As per Specified Engineer-In-charge :Removal of surplus spoils/earth from the site of work if required, will be decided by the Engineer in charge. He must take up tantative quantities in writting with Local Administrations (M.C./ N.A.C./ Panchyat/ Owner of the project) so that surplus spoils/ earth may be filled in public place (the destination/ destinations). Before so fillings, levels of site be recorded with respect to fixed bench mark near site and then again levels be recorded after filling. Record actual measurement of earth filling and lead in measurement book (loading or unloading will not be payable). If local administration do not response to repeated requests, then Engineer in charge will decide the destination in public intrest and the record the reasons of his choice and paid accordingly.

50185.64

-

-

... More
Extra for filling for earth in 15 cm layer and compaction.

208196.67

-

-

... More
Cement concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type

158.23000000000002

-

-

... More
Providing and Fixing of Form Work for Block

7417.799999999999

-

-

... More
First class dry brick on edge flooring or paving in ordinary bonded courses or in herring bond or other special courses or bond.

1192.75

-

-

... More
Total for Bill No. 23

-

-

-

... More
Bill No.- 24 Brick Cum RCC Rectangular Manhole Chamber and Raising of Manhole

-

-

-

... More
Excavation mannually in trenches with straight or open cutting in a built up street / lanes having wall to wall width upto 3 metre for sewers and manholes to full depths as shown in drwaings, including shoring, dressing to correct sections and dewatering of rain water provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, ,fixing and maintenance of caution boards,fencing, refilling trenches, watering , dressing and restoration of surface to orignal level and removal of surplus spoils from the site of works up to 15 metre,for all works other than connections to complete in all respects. Where wall to wall width is upto 3.0 Mtr. where as in open area or built up street/lane having wall to wall width more than 3.0 Mtr, excavation will be done by mechnical means. In case of unavodidable circumstances, if, manual excavation is required other than the specified above, Superintending Engineer is competent to permit after his personal satisfaction subject to prior approval on the record. If prior approval is not accoded for manual excavation then contractor will be paid as excavation by mech. means and the contractor will have no claim for that.

-

-

-

... More
For Depth not exceeding 2.0 m B.G.L

-

-

-

... More
For all clases of soil except rocky

8655

-

-

... More
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewer and manhole to full depths as shwn in drawing,including dressing to correct sections and dewatering ,provision for diversion traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods,watching,etc.,,fixing and maintenance of caution boards,fencing refilling trenches, watering , ramming and restoration of surface to orignal level and removal of surplus spoils from the site of works up to one chain (15 m) complete in all respects.

-

-

-

... More
For depth not exceeding 3 m. B.G.L

-

-

-

... More
For all classes of soil except rocky

46392

-

-

... More
For depth exceeding 3.0 m. but not exceeding 4.50 m. B.G.L

-

-

-

... More
For all classes of soil except rocky

5941.37

-

-

... More
For depth exceeding 4.50 m. but not exceeding 6.0 m. B.G.L

-

-

-

... More
For all classes of soil except rocky

743

-

-

... More
For depth exceeding 6.0 m. but not exceeding 7.5 m. B.G.L

-

-

-

... More
For all classes of soil except rocky

11.89

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

11390.456000000002

-

-

... More
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.

11006.820000000002

-

-

... More
Cement Concrete 1:4:8 with stone ballast of size using concrete mixer volumetric type.

-

-

-

... More
20mm gauge

8030.34

-

-

... More
Cement Concrete 1:2:4 with stone ballast or Shingle using concrete mixer volumetric type.

440.26999999999987

-

-

... More
Reinforced cement concrete M-20 mechancially batch mixed using batch type concrete mixer as per IS :1791 and vibrated by neddle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.

3749.54

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

8748.039999999999

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level.

8748.039999999999

-

-

... More
12.5 mm thick cement plaster 1:2

57422.02999999999

-

-

... More
Cement rendering on plaster 1mm thick

68428.85000000002

-

-

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete.

2362.19

-

-

... More
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).

-

-

-

... More
560 mm id R.C.C. Manhole cover with frame

-

-

-

... More
Extra heavy duty

4615.2

-

-

... More
Heavy duty

3076.8

-

-

... More
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.

16876

-

-

... More
Extra over the rate laid down in this schedule for cement concrete work for making and finishing benching and complicated floor work in manholes including formation of channels and bulldozing and smooth finishing the surface accurately to templete.

11006.820000000002

-

-

... More
Extra for Disposal of Surplus Spoils/Earth if any beyond 15 Mtr as covered for item no 29.4 to 29.5 (1 Km Lead). As per Specified Engineer- In -charge Note : 13 Removal of surplus spoils/earth from the site of work if required, will be decided by the Engineer in charge. He must take up tantative quantities in writting with Local Administrations (M.C./ N.A.C./ Panchyat/ Owner of the project) so that surplus spoils/ earth may be filled in public place (the destination/ destinations). Before so fillings, levels of site be recorded with respect to fixed bench mark near site and then again levels be recorded after filling. Record actual measurement of earth filling and lead in measurement book (loading or unloading will not be payable). If local administration do not response to repeated requests, then Engineer in charge will decide the destination in public intrest and the record the reasons of his choice and paid accordingly.

60249.95000000001

-

-

... More
Total for Bill No. 24

-

-

-

... More
Bill No.- 25: House Service connection (Pipe Line)

-

-

-

... More
Excavation mannually in trenches with straight or Open cutting in a built up street / lanes having wall to wall width upto 3 metre for sewers and manholes to full depths as shown in drwaings, including Shoring, dressing to correct sections and dewatering of rain water provision for diversion for traffic, protechtion of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, Pegs, Sightrails, boning rods, ,fixing and maintenance of caution boards,fencing refilling trenches, watering , dressing and restoration of surface to orignal level and removal of surplus spoils from the site of works up to 15 mtrs, for all works other than connections to complete in all respect.

-

-

-

... More
For depths not exceeding 2.0 mtr B.G.L

-

-

-

... More
For all classes of soil except rocky

35737.66

-

-

... More
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.

4022.98

-

-

... More
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.

-

-

-

... More
Class SN-8

-

-

-

... More
110 mm O/D

68585

-

-

... More
Construction of brick masonry inspection chambers size as given below up to 0.60 metre average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50 mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping 50 mm. thick with 455 mm x 455 mm,455 mm x 610 mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.

-

-

-

... More
Size 450mm x 450mm inside with RCC 455mm x 455 mm cover & frame light duty double seal.

13717

-

-

... More
Total for Bill No. 25

-

-

-

... More
Bill No.- 26: Rehabilitation of sewer Line

-

-

-

... More
Rehabilitation of 760 mm sewer Line

500

-

-

... More
Total for Bill No. 26

-

-

-

... More
Bill No.- 27: Laying of SH Trenchless Crossing (Micro-tunneling)

-

-

-

... More
Amritsar-Pathankot Road (APK) Road -1000 mm dia carrier pipe with 1600 mm casing

60

-

-

... More
Batala-Jalandhar old By-pass towards STP Site-1600 mm dia carrier pipe with 2200 mm casing

60

-

-

... More
Total for Bill No. 27

-

-

-

... More
Bill No. 28 Environment Management Plan Implementation Cost

-

-

-

... More
Air quality monitoring: Once during the preconstruction stage at sensitive receptors, congested areas and upwind and downwind of construction camps and material storage areas.The parameters to be monitored are PM10, PM 2.5, SOx, NOx and CO. Each sample shall be for a 24 hour period and methods approved by CPCB shall be adopted. The collection of sample and testing shall be carried out by aNational Accreditation Board for Testing and Calibration Laboratories (NABL) Accredited /Ministry of Environment Forest and Climate Change (MoEF&CC) / Punjab Pollution Control Board (PPCB)recognised Laboratory.The location of the sampling has been indicated in the Environmental Monitoring Plan of the IEE report

20

-

-

... More
Air quality monitoring: (a) once during construction at sensitive receptors, congested areas (b) quarterly during construction,upwind and downwind of construction camps and material storage areas except for monsoon season The parameters to be monitored are PM10, PM 2.5, SOx, NOx and CO. Each sample shall be for a 24 hour period and methods approved by Central Pollution Control Board (CPCB) shall be adopted. The collection of sample and testing shall be carried out by a NABL accredited /MoEF&CC / PPCB recognised Laboratory.The location of the sampling has been indicated in the Environmental Monitoring Plan of the IEE report

30

-

-

... More
Noise levels monitoring Once during the preconstruction stage at sensitive receptors, congested areas, and upwind and downwind of construction camps and material storage areas Each monitoring schedule shall be over a duration of 24 hrs period and methods approved by CPCB shall be adopted. The collection and testing of sample shall be carried out by a NABL accredited /MoEF&CC / PPCB recognised LaboratoryThe location of the sampling has been indicated in the Environmental Monitoring Plan of the IEE report

20

-

-

... More
Noise levels monitoring (a) once during construction at sensitive receptors, congested areas (b) quarterly during construction upwind and downwind of construction camps and material storage areas. Each monitoring schedule shall be over a duration of 24 hrs period. Each monitoring schedule shall be over a duration of 24 hrs period and methods approved by CPCB shall be adopted. The collection and testing of sample shall be carried out by a NABL accredited /MoEF&CC / PPCB recognised LaboratoryThe location of the sampling has been indicated in the Environmental Monitoring Plan of the IEE report.

30

-

-

... More
Ground Water-once during preconstruction at the construction camps and material storage areas. The parameters to be monitored shall be as per IS 10500: 2012. Each sample shall be analysed as per the methods approved by CPCB.The collection and testing of sample shall be carried out by a NABL Accredited /MoEF&CC / PPCB recognised Laboratory

6

-

-

... More
Ground Water-a) quarterly during construction at the construction camps and material storage areas and 2 pipeline laying location, b) once after decommissioning at the construction camps and material storage areas.The parameters to be monitored shall be as per IS 10500: 2012. Each sample shall be analysed as per the methods approved by CPCB. The collection and testing of sample shall be carried out by a NABL Accredited /MoEF&CC / PPCB recognised Laboratory.

30

-

-

... More
Ground Water-a) once during decommissioing at the construction camps and material storage areas and 2 pipeline laying location, b) once after decommissioning at the construction camps and material storage areas.The parameters to be monitored shall be as per IS 10500: 2012. Each sample shall be analysed as per the methods approved by CPCB. The collection and testing of sample shall be carried out by a NABL Accredited /MoEF&CC / PPCB recognised Laboratory.

6

-

-

... More
Soil Testing- once before setting up the construction camps and material storage areas. The parameters to be monitored shall be pH, Elect. Conductivity (at 250C), Moisture (at 1050C), Texture (silt, clay, sand), Calcium (as CaO), Magnesium (as Mg), Permeability, Nitrogen (as N), Sodium (as Na), Phosphate (as PO4), Potassium (as K), Organic Matter, Oil and Grease, Heavy Metals, Poly Aromatic Hydrocarbons (PAH). Each sample shall be analysed as per the methods approved by CPCB. The collection and testing of sample shall be carried out by a NABL Accredited /MoEF&CC / PPCB recognised Laboratory.

30

-

-

... More
Soil Testing- once after decommissioning of the construction camps and material storage areas. The parameters to be monitored shall be pH, Elect. Conductivity (at 250C), Moisture (at 1050C), Texture (silt, clay, sand), Calcium (as CaO), Magnesium (as Mg), Permeability, Nitrogen (as N), Sodium (as Na), Phosphate (as PO4), Potassium (as K), Organic Matter, Oil and Grease, Heavy Metals, PAH. Each sample shall be analysed as per the methods approved by CPCB.The collection and testing of sample shall be carried out by a NABL Accredited /MoEF&CC / PPCB recognised Laboratory

6

-

-

... More
Capacity Building

-

-

-

... More
One day training on plans and protocols for Construction site, Standard operating procedures (SOP), Site-specific EMP, Traffic management plan,Spoils management plan, Waste management plan,Occupational Health and Safety, Community Health and Safety, Chance find protocol prior to mobilisation of the personnel on site

-

-

-

... More
Contractors Orientation to Workers (including manual labours) on Environment Management Plan (EMP) implementation (OH&S, core labour laws, spoils management, etc.) to be carried out once every year or as directed by the Project Implementation Unit (PIU) for the entire duration of the project.

-

-

-

... More
Civil Works (During Execution)

-

-

-

... More
(Note: Part of following specifications are covered in specification of works items for safety, therefore the rates shall be quoted for the specifications not covered in other items.)

-

-

-

... More
Providing Barricading for Trenches using 80-100 mm dia Wooden Ballies as vertical post, atleast1.5mabove ground level and at least 30-45 cm below ground level at a spacing of 3 m. Two rows of PVC Tape (preferably red in colour) strip barricading horizontal strip securely tied by the vertical members. Vertical members shall be painted in red and white colour. Rate is inclusive removal and cleaning of site complete in all respect.

400

-

-

... More
Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe ("B" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing suitably two rows of 100mm wide PVC Tape preferably of red colour. The M.S. pipe shall be painted in red and white colour strips as per approved pattern as and when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading the hole shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis).

900

-

-

... More
Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe ("B" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing two rows of 40mm dia M.S. pipe ("B" class) as horizontal members with nuts & bolts. Both vertical and horizontal members shall be painted in red and white colour strips as per approved pattern as when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading holes shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis).

900

-

-

... More
Providing and Fixing Minimum 0.63mm thick GI corrugated sheets (minimum width of each sheet shall be 60 cm) for covering the barricading in one/ two rows one above another and painting in red and white stripes as per the specifications and directions of the Engineer Incharge with proper fixing arrangements with GI limpetwashers nuts and bolts complete in all respect.

900

-

-

... More
Arranging of tractor/ truck mounted water tanker (4000/5000 L) with sprinkling arrangement at the back for suppression of dust in the construction areas.

2880

-

-

... More
Supplying and fixing of cautionary and or information signsboards including the cost of posts, fixtures, fixing, foundation, fitting and fixing. Sheeting will be made of encapsulated lens type of retro-reflective type and message / borders will be screen printed complete as per screen specification in IRC SP 55: 2001. To be made available at all time at the work sites as required and directed by the engineer

100

-

-

... More
Providing of red and white reflective level traffic cone made of low density polythene (LDPE) material with square base of 390X390X 35 and height of 770 mm , 4 kg in weight and placed at 1.5 m interval all as per BS: 873 including cost of material , labour, loading, unloading, lead, lift, shifting, transportation etc. and as per and IRC SP 55: 2015

625

-

-

... More
Supplying and fixing of flashing beacon warning lights including the cost of posts, fixtures, fixing, foundation, fitting and fixing,cost of material, labour, loading, unloading, lead, lift, shifting, transportation etc. and as per specification in IRC SP 55: 2001

100

-

-

... More
Provision and maintenance of Bio toilets with 1 male and 1 female units including cost of material, labour, loading, unloading, lead, lift, transportation, shiftingetc. And shall be made available at worksite at the direction of the PIU. The facility shall complete with water arrangement, privacy, lighting arrangement. The WC and /urinals should be made of stainless Steel and the partitions should be made of aluminium framework with FRP panels. The bio-digester tank should be approved by Defence Research & Development Organisation (DRDO )or any other competent agency.The whole toilet shall be mounted on MS framework with skids; Overhead water tank shall be made of HDPE with proper arrangement of ball cock and mosquito proof cover. These should also be provided with two dustbin for wet and dry waste. The bio-digester toilets shall be mounted on skids and shall not require any creation of permanent structure so that they can be shifted from one worksite to another

10

-

-

... More
Provision of Helmets (IS CODE 2925: 1984), Safety Shoes (IS CODE 5852 : 1996), Googles (•IS CODE 5983 : 1980), Reflective Jackets, mitten/ gloves (IS 2573) , safety nose masks to all personnel (including temporary labour) involved in the worksites

-

-

-

... More
Provision and maintenance of First-Aid Kits complete with (i) 3 nos. of small sterilised dressings; (ii) 3 nos. of 3 medium size steriliseddressings; (iii) 3 nos. of large size sterilised dressings; (iv) 3 large sterilised burns dressings; (v) 1 (30 ml) bottle containing 2 % alcoholic solution of iodine; (vi) 1 (30 ml) bottle antiseptic liquid; (vii) 1 (30 gms) bottle of potassium permanganate crystals; (viii) 1 pair of scissors;(ix) 1 Forceps;(x) antiseptic ointment;(xi) 3 nos. of bandage; (xii) 1 Absorbent Cotton Wool;(xiii) 1 nos. of Eye Wash Cup;(xiv) 2 Eye Pad (6x8 cm);(xv) 2 Adhesive Tape;(xvi) 5 Bandage Roller 3"x3 MT;(xvii) 5 Bandage Roller 2"X 3 MT;(xviii) 40 First Aid Bandage (Wash proof);(xix) 19x72 mmTournicate Belt; (xx) 1 Micropore Tape 0.5" to be made available at the construction camp and all worksites.

10

-

-

... More
Provision and maintenance of waste collection bins in sets of 2 (blue and green) for collection of municipal solid waste generated at the worksite including cost of material, labour, loading, unloading, lead, lift, shifting, transportation etc.

40

-

-

... More
Environment, Health & Safety Engineer/Supervisor havingBachelors in Env Science / Management/ B.Tech (EnvEngg.) Diploma in Central Labour Institute / Regional Labour Institute (Mandatory)

24

-

-

... More
Environmental Permits such as CTE from PPCB for proposed 30 MLD STP Stage: Obtained CTE before Construction

-

-

-

... More
Environmental Permits such as CTO from PPCB for proposed 30 MLD STP Stage: Obtained CTO before operation

-

-

-

... More
Total for Bill No. 28

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.