Punjab State Power Corporation Limited Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 2,94,000Document Cost
Refer DocumentsTender Fee
₹ 5,900
Summary
7657/p-1/emp-12855 Dated 18-02-2025
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_POWER_135137_1Tender No
7657/P-1/EMP-12855 dt. 18.02.2025Tender Authority
Punjab State Power Corporation Limited ViewPurchaser Address
-Website
http://https://www.pspcl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
ALM3.5Cx240 mm2 Strip Armoured
800
-
-
... More
ALM3.5Cx150mm2 Strip Armoured
300
-
-
... More
ALM 3.5Cx70mm2 Wire Armoured
500
-
-
... More
ALM 3.5Cx35mm2 Wire Armoured
1000
-
-
... More
ALM3Cx10 mm² Wire Armoured
3000
-
-
... More
ALM3Cx16 mm² Wire Armoured
2000
-
-
... More
ALM 3C x 25 mm² wire Armoured
2000
-
-
... More
ALM3Cx35 mm² Wire Armoured
2000
-
-
... More
ALM3Cx50 mm² Wire Armoured
1700
-
-
... More
ALM 3Cx70mm2 Wire Armoured
3000
-
-
... More
ALM 3Cx120 mm2 wire Armoured
500
-
-
... More
ALM 3Cx400 mm2 wire Armoured
200
-
-
... More
ALM 2C x 10mm2 Wire Armoured
2000
-
-
... More
ALM 2C x16mm² Wire Armoured
1200
-
-
... More
ALM 2Cx35 mm² Wire Armoured
1000
-
-
... More
1100V, FRLS PVC -ST2 Insulated as per IS-694/2010 with latest amendments, with flexible/multistrand ALUMINIUM conductor ( IS-8130 ) of following parameters (MATERIAL / CORES / CONDUCTOR CORE AREA IN MM2) :
-
-
-
... More
ALM 2C X 2.5mm2 Twisted Flexible
1000
-
-
... More
ALM 1 C X 1.5mm2 Flexible
2700
-
-
... More
ALM 1 C X 2.5mm2 Flexible
2200
-
-
... More
1100V PVC Insulated as per IS-694/2010 with lastest amendments ,with flexible /multistrand annealed COPPER Conductor as per 8130/1984 of following parameters (Material/ CORE/CONDUCTOR CORE AERA IN MM2
-
-
-
... More
Cu 1Cx6mm2 un-armd
50
-
-
... More
Cu 1Cx10mm2 un-armd
100
-
-
... More
Cu 1Cx25mm2 un-armd
50
-
-
... More
Cu 1Cx50mm2 un-armd
50
-
-
... More
CU 2C X 0.75mm2 Twisted Flexible
500
-
-
... More
CU 1C x1.5mm2 Grey Color
500
-
-
... More
CU 1C x2.5mm2Red color
500
-
-
... More
1100V, PVC insulated conforming to IS: 1554 (Part-I/ 1988) with latest amendments, extruded PVC inner sheathed, extruded FRLS PVC ST2 outer sheathed, Multi-stranded annealed TINNED COPPER conductor as per 8130/1984 , armoured (IS 3975), of following parameters ( MATERIAL / CORES / CONDUCTOR CORE AREA IN MM2) :
-
-
-
... More
CU 19C *2.5mm2 Armd
1800
-
-
... More
CU 12C *2.5mm2 Armd
500
-
-
... More
CU 7C * 2.5mm2 Armd
2000
-
-
... More
CU 4C*2.5mm2 Armd
500
-
-
... More
1100V, XLPE insulated conforming to IS: 7098 (Part-I/ 1988) with latest amendments, extruded PVC inner sheathed, extruded FRLS PVC ST2 outer sheathed, Multi-stranded annealed COPPER conductor as per 8130/1984 , armoured (IS 3975), of following parameters (MATERIAL / CORES / CONDUCTOR CORE AREA IN MM2) :
-
-
-
... More
CU 3C x16mm2 wire un-armd
600
-
-
... More
CU 3C x25mm2 wire un-armd
100
-
-
... More
1100 volts grade flexible /tralling cables with annealed tinned copper conductor as per IS 8130/1984. EPR insulated 4 power core of 10sqmm and 5 control cores of 2.5 sqmm in one bunch and collectively screened with ATC wires braid with minimum 70% covered ,all power & control laid together with one steel conductor between power & control cores CSP under and outer sheathed as per IS 6380/1984 with elastomeric compound (type SE-3) reinforcement with RPCT and overall CSP sheathed (type SE-4) generally conforming to IS 9968/Part-1/81 lastest pf siize 4 core x 10 sqmm + 5 core x 2.5 sqmm. The cable shall be in single length of 250mtr. Colour coding of power cores –Red,Yellow ,Blue & Green and control cores should be numbered or colour coded .The overall dia of the cable shall be 41.50 mm 0.5%
-
-
-
... More
CU 4 core x 10sq.mm + 5 core x2.5sq.mm
500
-
-
... More
1100 volts grade flexible /tralling cables with annealed tinned copper conductor as per IS 8130/1984. EPR insulated 4 power core of 35sqmm unscreened and 5 control cores of 2.5 sqmm individually screened with ATC wires braid with minimum 70% covered ,all power & control laid together with one steel conductor between power & control cores CSP under and outer sheathed as per IS 6380/1984 with elastomeric compound (type SE-3) reinforcement with RPCT and overall CSP sheathed (type SE-4) generally conforming to IS 9968/Part- 1/81 lastest pf siize 4 core x 35 sqmm + 5 core x 2.5 sqmm. The cable shall be in single length of 250mtr. Colour coding of power cores –Red,Yellow ,Blue & Green and control cores should be numbered or colour coded .The overall dia of the cable shall be 48.00 mm 0.5%
-
-
-
... More
CU 4 core x 35 sq.mm + 5 core x2.5 sq.mm
400
-
-
... More
1100 volts grade FLEXIBLE/TRAILING CABLES WITH ANNEALED TINNED COPPER CONDUCTOR as per IS: 8130/1984, EPR insulated 16Cx2.5.mm2 (out of which 2 cores should be individually for communication with ATC wire with minimum 70% covering & 2 screened core are laid up together), CSP inner and outer sheathed as per IS:6380/1984 with elastomeric compound (type SE-3) reinforcement with RPCT and overall CSP sheathed (type SE-4),outer dia 26-28mm generally conforming to IS: 9968/Part-1/81 with latest amendments if any, of size 16C x 2.5 mm2. trailing cable in single length without any joint of minimum length 52 m.
-
-
-
... More
CU Flex/Trail 16X2.5mm2
400
-
-
... More
1100 volts grade flexible/tralling cables with annealed tinned copper conductor as per 8130/1984 EPR insulated having cores of following sizes ,outer dia ,outer color & types CSPinner and outer sheathed as per IS 6380 /1984 with elastomeric compound (typeSE-3) reinforcement with RPCT and overall CSP sheathed (type SE-4) generally conforming to IS :9968 Part-1/81 with latest amendment’s if any .The cable shall be in single length OR minimum length should be 500 mtr. (if is to be made in more than one piece Cores should be numbered Or colour coded.
-
-
-
... More
16 core x 2.5sqmm ,screened collectively 23.5mm outer dia
3500
-
-
... More
4 core x2.5sqmm 21mm outer dia screened
200
-
-
... More
2 core x 2.5 sqmm
400
-
-
... More
FRLS Instrumentation cable ,1100 Volt grade annealed copper electrolytic conductor ,multi stand ,PE insulated cores laid together to make pairs and colour coded ,with tinned copper drawn wire ,overall screened with ALU-Mylar tape ,overall FRLS sheathed of thickness 1.5to 1.8 mm in Grey colour ,GI armoured ,conforming to IS :8130/1994, IS 1554 with latest amendments and IEC : 754 part-1 of following sizes:
-
-
-
... More
Cu 4 pair x 1.5mm2 colour coded Armed.
1000
-
-
... More
Cu 8 pair x 1.5mm2 colour coded Armed.(ATRS)
1000
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%