If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Punjab State Power Corporation Limited - PSPCL Tender

Goods
Machinery and Tools
Eprocure
Opening Date29 Nov 2024
Closing Date7 Jan 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Procurement Of Contact Type Temperature Gauges For Various Auxiliaries Of Stage-ii And Iii (interlock And Fsss Of Ggsstp Roopnagar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Contact type Temp. Gauge for motor Bearing temp. of Coal Mills stage-III. Range 0 to 120ºCDetailed specifications are as per Annexure-VII

7

-

-

... More
Contact Type Temp. gauge for Fan Brg. Of ID/PA fan of Stage- II. Range 0 to 150ºC, capillary Length 7 meter. Base plate as per Annex. III, Detailed specifications are as per Annexure–B&VIII

10

-

-

... More
Contact Type Temp. Gauge for Fan Brg. Of FD Fans of Stage- II, CHP crushers Range 0 to 150ºC, Base plate as per Annex. III, Detailed specifications are as per Annexure–B, IX

10

-

-

... More
Contact Type Temp .Gauge for Motor Brg. & air motor temp. of BFP of Stage- II. Range 0 to 100ºCBase plate as per Annex. VI, Detailed specifications are as per Annexure–A, X

10

-

-

... More
Contact Type Temp .Gauge for Motor Brg. Of CWP/PA/BCW / Bottom Ash Pump bearing and CWP thrust bearing of Stage-III, Range 0 to 120ºC, Detailed specifications are as per Annexure– XI

20

-

-

... More
Contract Type Temp. Gauge for Motor Brg. of CWP’s Stage-II.Range 0 to 120ºCBase plate as per Annex. III, Detailed specifications are as per Annexure–A &XII

8

-

-

... More
Contact Type Temp. Gauge for Thrust Brg. of CEP Stage-II., Base plate as per Annex. III, Detailed specifications are as per Annexure–B, XIV

2

-

-

... More
Contact Type Temp. Gauge for ID Fan Lub Oil System of Stage- II & III . Range 0 to 100ºC. Detailed specifications are as per Annexure–C,XVIII

15

-

-

... More
Contact Type Temp. Gauge for Generator Hydrogen Gas Temp. of Stage- II . Range 0 to 80ºC.Detailed specifications are as per Annexure–C , XX.

2

-

-

... More
Contact Type Temp. Gauge 0 to 120ºC for ID/BFP motors and air motors, of BFP of Stage-III. Detailed spec. as per Annexure-XXI.

20

-

-

... More
Contact Type Temp. Gauge 0 to 120ºC for motor brg Temp. of FD/CEP and Fan brg temp of PA of Stage-III. Detailed spec. as per Annexure-XXII

8

-

-

... More
Contact Type Temp. Gauge 0 to 80ºC for Gen. H2 Gas Temp. Alarm of Stage-III. Detailed spec. as per Annexure-XXIII. with capillary of 7meters

2

-

-

... More
Contact Type Temp. Gauge 0 to 150ºC for working oil temp of BFP’s of Stage-III. Detailed spec. as per Annexure-XXIV.

2

-

-

... More
Contact Type Temp. Gauge 0 to 120ºC for Fan Brgs. Of ID/FD Fans of Stage-III. Detailed spec. as per Annexure-XXV

10

-

-

... More
Contact Type Temp. Gauge 0 to 120ºC for CEP thrust beg temp of Stage-III. Detailed spec.as per Annexure-XXVI.

2

-

-

... More
Contact Type Temp. Gauge for BCW motor Brg. of stage-II. Range 0-100 ºC, Base Plate Annex.-III, Spec. as per Annexure –A, XXVII

8

-

-

... More
Contact Type Temp. Gauge for Thrust Brg of CWP of stage-II. Range 0-100 ºC-Base Plate as per Annex. –III ,Spec. as per Annexure –B, XXVIII

4

-

-

... More
Contact Type Temp. Gauge for Thrust Brg of BCW Pump of stage-II. Range 0-120 ºC, Spec. as per Annexure –XXX

3

-

-

... More
Contact Type Temp. Gauge for BFP Bearing no. 1 of stage I. Range 0 to 120ºC Detailed specifications are as per Annexure –F &XXXV.

2

-

-

... More
Contact Type Temp. Gauge for BFP Bearing no. 2 of stage-I. Range 0 to 120ºC Detailed specifications are as per Annexure –F &XXXVI

2

-

-

... More
Contact Type Temp. Gauge for BFP Bearing no. 3&4 of stage-I. Range 0 to 120ºC Detailed specifications are as per Annexure –F &XXXVII.--

2

-

-

... More
Contact Type Temp. Gauge for BFP Bearing no. 5 of stage-I. Range 0 to 120ºC Detailed specifications are as per Annexure –F &XXXVIII.--

2

-

-

... More
Contact Type Temp. Gauge for BFP Bearing no. 6 of stage-I. Range 0 to 120ºC Detailed specifications are as per Annexure –F &XXXIX.--

2

-

-

... More
Contact Type Temp. Gauge for BFP Bearing no. 7&10 of stage-I. Range 0 to 120ºC Detailed specifications are as per Annexure –F &XXXX

2

-

-

... More
Contact Type Temp. Gauge for BFP Working oil temp. of stage-II. Range 0 to 200ºC.Base Plate as per annex XXXXV.Detailed specifications are as per Annexure –F &XXXXII.

2

-

-

... More
Contact Type Temp. Gauge for BFP Brg. No.1, 3-4,5,6 of stage-II. Range 0 to 120ºC Base Plate as per annex XXXXV. Detailed specifications are as per Annexure –F & XXXXIII.

10

-

-

... More
Contact Type Temp. Gauge for BFP Brg. No. 2,7-10 of stage-II. Range 0 to 120ºCBase Plate as per annex XXXXV. Detailed specifications are as per Annexure –F &XXXXIV.

7

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.