Public Works Department Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Nov 2024
Closing DateCancelled
Tender Amount₹ 1,53,19,62,084 
Notes
Download

Costs

  • EMD

    ₹ 3,06,39,242
  • Document Cost

    ₹ 1,00,000
  • Tender Fee

    ₹ 5,900

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹50,600/MT*
Punjab

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.

15925.82

191

3053568.03

... More
Extra For compensation & royalty for Ordinary earth/ Ordinary clay taken from private land.

38065.35

108

4145728.86

... More
Earth filling

-

-

-

... More
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres

8723.45

521

4544897.19

... More
Supplying of Good Earth brought from outside including carriage to site and loading unloading at site complete in all respect as directed by Engineer in charge.

38065.35

553

21075124.27

... More
Site clearance

-

-

-

... More
Excavation in dumped stone or malba including stacking of unserviceable material separately and disposal of unserviceable material. Lead up to 50 m and lift up to 1.5 m, disposed material to be neatly dressed in all kinds of soils.with 10.00 km Leads (245.43+7%)+332.00=594.61

29640

626

18567137.26

... More
Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil.

39520

15

624514.8

... More
Damp proof course 4 Cm thick cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded

339.96

370

125919.59

... More
Sand filling under floor and in wells of bridge foundation including handling withing 100 metres

78.17

1058

82759.91

... More
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 (Part 2) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm.

3387.08

391

1327401.59

... More
Note :- The Engineer in Charge will ensure consumption of chemical as per manufacturer's specifications & minimum 5 years warranty from the concerned dealer.

-

-

-

... More
CENTERING & SHUTTERING

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

3289.28

221

727704.36

... More
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.

-

-

-

... More
Basement+Foundations

2347.95

469

1103209.2

... More
Ground Floor

551.62

469

259182.85

... More
First Floor

551.62

480

264994.12

... More
Second Floor

551.62

490

270805.39

... More
Third Floor

551.62

501

276616.67

... More
Fourth Floor

268.74

512

137593.1

... More
Centring and shuttering for columns (Square or rectangular or poly gonal in plain)

-

-

-

... More
Basement+Foundations

4454.8

545

2431042.27

... More
Ground Floor

3548.88

545

1936670.5

... More
First Floor

2540.88

556

1413359.42

... More
Second Floor

2453.4

566

1390545.41

... More
Third Floor

2453.4

577

1416391.98

... More
Forth Floor

1163.28

587

683837.64

... More
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels.

-

-

-

... More
Basement+Foundations

3420.23

443

1516951.67

... More
Ground Floor

4237.35

443

1879362.84

... More
First Floor

2771.92

454

1258615.47

... More
Second Floor

2646.51

464

1229550.69

... More
Third Floor

2646.51

475

1257431.66

... More
Forth Floor

801.91

485

389460.55

... More
Centering and shuttering for arches of varandah, door and windows openings.

-

-

-

... More
Ground Floor

222.19

1019

226588.74

... More
First Floor

81

1030

83456.16

... More
Second Floor

178.2

1040

185480.9

... More
Third Floor

86.4

1051

90840.36

... More
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.

-

-

-

... More
Basement+Foundations

9792.33

560

5488231.09

... More
Ground Floor

7886.42

560

4420040.68

... More
First Floor

6467.99

571

3693200.7

... More
Second Floor

6467.99

581

3761340.93

... More
Third Floor

6467.99

592

3829481.17

... More
Forth Floor

2343.05

602

1411926.62

... More
Centring and shuttering for stair cases with sloping soffits including risers and stringers.

-

-

-

... More
Basement+Foundations

201.6

469

94723.98

... More
Ground Floor

1042.33

480

500731.16

... More
First Floor

201.6

490

98971.69

... More
Second Floor

201.6

501

101095.55

... More
Third Floor

201.6

512

103219.4

... More
Terrace Floor

201.6

522

105343.26

... More
CEMENT CONCRETE

-

-

-

... More
Cement concrete 1:2:4 with stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type

-

-

-

... More
Basement+ Footings

2607.93

5462

14245494.01

... More
Ground Floor

622.77

5509

3431327.42

... More
First Floor

351.81

5700

2005470.75

... More
Second Floor

333.28

5891

1963423.4

... More
Third Floor

370.89

6081

2255705.26

... More
Fourth Floor

683.49

6272

4287233.07

... More
REINFORCEMENT WORK

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth

4407.47

6517

28727583.99

... More
Reinforced cement concrete M-35 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth

708.91

6831

4843175.08

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth

2033.97

6517

13257300.76

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.

-

-

-

... More
Ground Floor

304.69

7309

2226993.62

... More
First Floor

106.85

7499

801366.66

... More
Second Floor

63.44

7690

487851.82

... More
Third Floor

63.44

7881

499947.99

... More
Fourth Floor

30.9

8071

249457.41

... More
Reinforced cement concrete M-35 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.

-

-

-

... More
Ground Floor

450.9

7623

3437257.13

... More
First Floor

409.81

7813

3202174.4

... More
Second Floor

409.81

8004

3280319.07

... More
Third Floor

409.81

8195

3358463.74

... More
Fourth Floor

171.91

8338

1433413.17

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.

-

-

-

... More
Ground Floor

1554.05

7309

11358741.15

... More
First Floor

1588.17

7499

11910943.71

... More
Second Floor

1614.9

7690

12419347.9

... More
Third Floor

1616.92

7881

12743241.98

... More
Fourth Floor

513.88

8071

4147998.36

... More
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )

16034.25

358

5743309.43

... More
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)

16034.25

92

1486503.62

... More
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey

16034.25

23

371625.9

... More
Providing, hoisting and fixing in super structure for first storey precast reinforced cement concrete work in string courses,bands, copings, bed plates, anchor blocks, plain window sills and the like including the cost of required centring & shuttering, cost of 1:2:4 hand mixed (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size)but excluding the cost of steel reinforcement.(Qty of each unit shall not exceed 0.04 cum)

8.99

9245

83106.09

... More
Extra for providing and mixing water proofing material in cement plaster work @ 1 kg per 50 kg of cement.

137161.36

72

9970464.91

... More
STEEL REINFORCEMENT

-

-

-

... More
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 D grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete

-

-

-

... More
Basement+Foundation

10277.43

7962

81836400.65

... More
Ground Floor

10426.21

7962

83021112.23

... More
First Floor

3178.96

7976

25356749.42

... More
Second Floor

3132.22

7990

25026852.49

... More
Third Floor

3135.26

8003

25094061.46

... More
Fourth Floor

1075.04

8017

8619169.05

... More
Rebarring (Chemical Anchors) of 10 mm dia bar, hole size 14mm, depth 100mm with 10ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive ) rebaring chemical complete in all respect.

150

194

29234.63

... More
Rebarring (Chemical Anchors) of 12 mm dia bar, hole size 16 mm, depth 120 mm with 14 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive ) rebaring chemical complete in all respect.

250

319

79802.63

... More
Rebarring (Chemical Anchors) of 20 mm dia bar, hole size 25 mm, depth 200mm with 47 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive ) rebaring chemical complete in all respect.

300

666

200059.65

... More
BRICK WORK

-

-

-

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth

1121.83

6656

7467432.57

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.

-

-

-

... More
Ground Floor

1811.04

6801

12318432.46

... More
First Floor

1126.73

6955

7837200.08

... More
Second Floor

947.45

7109

6735887

... More
Third Floor

1108.62

7263

8052209.3

... More
Fourth Floor

1023.36

7417

7590376.4

... More
Extra for burnt brick work in arches excluding cost of shuttering. (c) More than 3 metres but less than 6 metres span

1625.85

881

1433638.19

... More
(a) Extra for profile walls

91.06

108

9881.14

... More
Dressed or moulded three brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required

2754.42

273

754462.09

... More
FLOORING WORK

-

-

-

... More
Floating coat of 1.5mm thick neat cement laid in one operation to the topping.

692.76

43

30200.13

... More
Conglomerate floor 50mm thick cement concrete topping 1:2:4 ( Using mechanical mixer for mixing of materials).

1019.96

425

433572.67

... More
Brick work with machine moulded modular bricks of class designation 125 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete above plinth level in super structure in cement mortar 1:6 (1 cement : 6 fine sand).

1589.2

9513

15118979.87

... More
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size 800x800x9.5 mm thick

17789.75

1903

33853893.48

... More
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.)

-

-

-

... More
Size 600x600 mm

777.2

1510

1174065.3

... More
Providing and laying full body vitrified tile in Skirting dado of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 12 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @ 3.30 kg I sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. of all colours and shades. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.

-

-

-

... More
Size 800x800x9.5 mm thick

838.14

1903

1594988.37

... More
Size 600x600x9.5 mm thick

14.18

1510

21415.36

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling grouting and finishing complete as per direction of Engineer-in-charge.

-

-

-

... More
Size 600x600 mm.

791.38

186

147567.56

... More
Size 800x800 mm.

18586.96

147

2741390.33

... More
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)

695.28

1920

1335247.85

... More
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

215.17

745

160399.18

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

10

417

4171.86

... More
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

-

-

-

... More
Basement Floor+Ground Floor

7184.7

1164

8368452.14

... More
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing

-

-

-

... More
Basement Floor+Ground Floor

3949.99

1415

5591182.31

... More
Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. (Note:- 20mm thick Granite (Telephone Black) Leather should be used for Staircase and Lift Front Wall)

50

3332

166643.16

... More
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1cement 3 coarse sand) and jointed with neatcement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.

-

-

-

... More
Basement Floor

0.6

3462

2070.2

... More
Ground Floor

0.6

3465

2072.08

... More
First Floor

0.6

3468

2073.97

... More
Second Floor

0.6

3471

2075.86

... More
Third Floor

0.6

3475

2077.75

... More
Fourth Floor

0.6

3478

2079.64

... More
Providing and laying flamed finish Granite stone 18mm thick in flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :

-

-

-

... More
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

-

-

-

... More
Basement

603.9

2216

1338581.23

... More
Ground Floor

2702.5

2219

5998796.49

... More
First Floor

630.26

2222

1400993.72

... More
Second Floor

630.26

2226

1402985.66

... More
Third Floor

630.26

2229

1404977.59

... More
Fourth Floor

630.26

2232

1406969.52

... More
Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

-

-

-

... More
Basement

4.78

2963

14174.99

... More
Ground Floor

4.78

2963

14174.99

... More
First Floor

4.78

2966

14190.11

... More
Second Floor

4.78

2969

14205.23

... More
Third Floor

4.78

2972

14220.34

... More
Fourth Floor

4.78

2976

14235.46

... More
38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1 :2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.

599.6

12020

7207461.82

... More
Providing & fixing glass strips 3mm thick in floor (a) 40mm wide

350

23

8111.95

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.

17327.16

633

10970752.84

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.

3009.34

106

320203.99

... More
Plain Cement Concrete Pavement Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with cement contents 350kg per cum and coarse and fine aggregates conforming to IS:383 mixed with concrete mixer using weigh batcher, laid in position over 125 micron thick polythene sheet, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, including provision of contraction and expansion joints as required, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications. (Steel Reinforcement Shall be paid as respective Items)

48.22

6112

294746.96

... More
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.

482.2

46

22351.71

... More
FINISHING WORK

-

-

-

... More
12.5 mm thick cement plaster 1:5

29716.1

199

5935913.39

... More
20mm thick cement plaster 1:5 in two coat work

15427.01

273

4224312.64

... More
Plastering on underside of ceiling 10 mm thick cement plaster 1:4.

34212.88

191

6540410.89

... More
Providing and fixing chicken mesh on brick work and RCC work junction made of galvanized low carbon wire, annealed wire of diameter 0.6 to 2.0mm distance between the faces of the hexagon 13 to 15mm complete in all respect.

4116.22

197

810913.78

... More
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish.

60930.5

84

5135222.39

... More
Applying priming coat with metal primer on new steel or iron work including preparation of surface. With special quality paint

3127.63

25

79078.88

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. With special quality paint

3127.63

69

217466.91

... More
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two coats)

56956.91

93

5340365.57

... More
Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm

3973.59

163

648856.72

... More
Providing and applying at all floors, heights and locations stone based texture finish of Heritage / Spectrum or approved equivalent make made from natural Granite stone based materials and Bonding agent made from pure acrylic co-polymer emulsion, Broad fungicide and Bonding agent mixed to a recommended quantity of water and applied with a trowels on to the surface, to be finished, in an average uniform coat of 1.5/2mm covering an area of about 0.5 sqm/kg of the mix. giving a uniform surface texture and applied by a trained texture applicators in a single coat. The finish shall be anti fading and non pigmented type with resistance to weathering. The texture shall be applied shall be applied over a surface coat of cement primer after duly clearing off any unwanted scratches and undulations by sand papering or using a wire brush before actual application begin complete including cost of all material, labour, machinery, T&P, curing, all leads, lifts and sampling, testing and water arrangements complete as per drawings, requirements, specification and as directed by the Architect / Employer.

1600.78

1173

1877709.5

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with aluminum Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:

1435.6

3277

4705090.71

... More
Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge.

13477.54

1391

18756335.26

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.

1268.8

1300

1649464.11

... More
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.

-

-

-

... More
With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles.

6415.76

1551

9956009.62

... More
Providing and Fixing Soundscapes Blade - Acoustical blade which are 40 mm thick, flat glass fiber panels with Humidity Resistance RH 90%, with factory fitted embedded metal insert with ¼” – 20 threading for fixing cable adjuster for hanging application. Soundscapes blades shall have sizes of 200x1200mm, 200x1600mm, 400x1200mm, 400x1600mm, 400x1800mm, 500x1200mm or 500x1600mm with both side laminated scrim finished with uniform water-based paint on all surface (including edges). Acoustical performance of 0.65 NRC(for 400mm high x 40mm thick baffles with 400mm on center distance and overall depth of construction 1000mm) as per ASTM C-423 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) in standard White color with Light reflectance 87% or in the color specified by the Architect (Shell / Tangerine / Cranberry / Moss / Kiwi / Reef / Lagoon), Fire Performance Class B2 – s1, d0 as per EN 13501-1 .The Soundscapes blade shall be made of Glass fiber panel with density of 110-120 Kg/ m3. as per specifications, drawing and as per directions of the Engineer-in-Charge.

1106.4

6985

7728204

... More
G.F.R.C. PANELS

1779.92

8902

15844851.4

... More
Supplying fitting and fixing with surveying, conceptualizing, designing, manufacturing and installing of glass fibre reinforced polymer (gfrc) composite decorative mould with thickness ranging from 30 to 50mm as per panel size and as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolithic composite structure as per approved technology to satisfy the work. The Panel shall be moulded with fire resistant grade unsaturated polyester resin shall be filled & covered with suitable fibre glass with three layers 450 matting from all sides. M.S. Frame work (hollow section or suitable size as per shop drawings & design) shall be fixed and M.S. Stay shall be provided at the bottom to steady the frame with (M.S hollow section) with FRP matting of various pattern as per design approved by EIC. The form liners of approved in 50-20 mm thk. In approved size, pattern, design, thickness and color shall be fixed in with dry fixing method. The form liners should be made from '53 grade' approved white portland cement in grade 18, quartz, fine silica sand, alkali resistant glass fibre manufactured. Polymers manufactured by approved manufacturer or equivalent, super plasticizers manufactured by approved manufacturer or equivalent with uv resistant synthetic inorganic pigments made by approved manufacturer or equivalent. The material casting should be done in synthetic rubber / frp for fixing of glass fibre reinforcement.

-

-

-

... More
The precast units shall be installed on ms pipe frame of suitable size with concealed fasteners and inclusive of all formwork, supports, base anchors, joint sealers, finial finishing and painting work etc. The rate including cost of installation, carriage, fixing in proper position for artistic/ aesthetics view, with cost of necessary masonry work if necessary with straining bolts special type m.s clamp, necessary packing, scaffolding and tightening the bolts and nuts for ms structure fabrication and erection, including necessary priming with oil bound metallic primer & painting with thinner based hi gloss metallic paint with pu finished, including cost of hoisting and placing the frames GFRC Module Panels in proper position all labour, materials and other incidental charges etc. All completer as per direction of engineer-in-charge including top metal finish.

-

-

-

... More
Providing and fixing at all floors, heights and locations Machine cut Brick tile Cladding 230x115x40 mm Machine cut Brick Tile Wall (laid flat on 230X115 face) fixed with cement mortar 1:3 (1 cement, 3 Sand) laid and jointed with neat cement slurry and the joints to be filled with matching grout 0.8 to 10 mm groves to be pointed finished with matt clear lacquered coated of transparent water proofing layer of Zycosil Organosilane Nanotechnology compounds as per manufacturer specifications maintaining all line, level and plumb. The tiles shall be laid in half over lap bond over this rough base surface with groves 8x8mm in joints in all directions – horizontal, vertical and depth. The grooves shall be maintained with the help of spacers of required size used around each tile.

15609.4

2666

41614659.67

... More
The final finish surface after completion shall be cleaned with diluted HCL solution to remove any stains and cement marks. The vertical surface of tiles cladding shall be given a supporting aluminium angle of size 35x35x5mm at each floor level with the help of anchor bolts (which shall be paid as separately as per respective item ). Minimum compressive strength of brick tile shall be 500kg/sqcm, maximum water absorption shall be 7%, Efflorescence should be "NIL". All tiles should have been fired at a kiln temperature not less than 1100 degrees celsius during the manufacturing process. The tile sample shall be got approved from the Engineer-in-charge before application.

-

-

-

... More
ACOUSTIC DUST REPELLENT FIRE RETARDANT FABRIC WALL PANNELLING

2766.38

7686

21262421.89

... More
Providing and Fixing of Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%. as per manufacturer specification including all accessories complete in all respects to the entire satisfaction of the engineer in-charge. The Item Includes cost for material and base frame complete in all respect as directed by engineer in charge.

-

-

-

... More
ACOUSTICAL PANEL WALL PANNELLING

829.91

7283

6044270.83

... More
Providing and Fixing 12mm walls tiles made of commercial BWP Ply with 3.5 to 4 mm thick one side veneer with PU polishing with an option of colour as per the choice of Architect/Engineer-in Charge of site 600mm x 1200mm. Highly recommended for walls as excellent noise absorption of 1 NRC a per ISO:354-1985 and ASTM 423-90 a, density 400kg/m3 , meets stringent fire rating ASTMD-876 & Fire Class-1 and Class P-Not easily ignitable as per BS-476-Part5,6,7, weather resistant as per IS:3308, Thermal insulation as per IS: 3346-1980 with relative humidity of 90% RH at 600 Celsius (1400 Fahrenheit) for 15 days = Deterioration. Tested as per En 131682001 and Ro Hs Complaint. installed on GI Studs 2400mm x 50mm Web thickness 0.5 mm, Flanges 15mm & 50mm fully knurled giving it high strength, Hot dipped Galvanized steel with 120 GSM Zinc Coating specially designed for acoustic vibration management and long life with backing of 50mm thick absorb wool tested as per fire retardant ASTMD 635-1991 & IS 15061-2002 for excellent result

-

-

-

... More
Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183 density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm) @ 60 cm and wire mesh of 12.5mm x 24g wire and mesh, for top most ceiling of building.

6028

582

3511825.39

... More
JOINERY WORK

-

-

-

... More
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position Code: IS 2202-1 (1999) (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick

433.67

2430

1054002.19

... More
Providing & Fixing decorative high pressure laminated sheet 1mm SF thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.

910.14

1171

1066221.73

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir orequivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :For fixed portion and chaukhats

6987.34

370

2591130.75

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir orequivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required.

349.37

387

135445.47

... More
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.

7336.71

71

525587.32

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item)

-

-

-

... More
Float glass panes of 5 mm thickness

63.01

1090

68709.17

... More
Providing and Fixing Single Glazing with 6mm thick glass with high perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge.

214.2

2687

575657.89

... More
Providing and fixing Stainless Steel sliding door bolts of Satin finish, of Grade SS 304, with SS nuts and screws etc. including labour , Material & equipment or machinery required complete in all respect to the satisfaction of Engineer-in-charge/Architect. 300x16 mm

14

1103

15442

... More
Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

176

90

15945.78

... More
Providing & fixing 9" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

175

153

26916.93

... More
Providing & fixing 6" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

176

250

44129.01

... More
Providing & fixing 8" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

175

328

57521.1

... More
Providing and fixing aluminum grill 6.3 mm including cost of necessary fittings i.e. screws,u Type Beading etc. complete

152.4

534

81400.57

... More
Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality).

149

1838

273915.27

... More
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete (All Floors) I.S.I Designation No. 1 (size of door up to 851mm - 1000mm)

155

1380

213913.18

... More
Providing and fixing aluminum Wire Mesh including cost of necessary fittings i.e.screws,u Type Beading etc. complete

152.4

759

115759

... More
Supply & installation of Frameless Glass Partition of 12mm thick clear tempered glass of approved equivalent make to be fixed with Wall Connecting Profile no 9137812 base rail with fixing holes incl of clamping parts with screws and gasket for 12 mm glass with SS cover profile on both side having std lenth of 3 per metre, Finish : SS , The WCP should be used on top and bottom of the glass only complete in all respect including any kind of framing / support required for the fixed glass and should be as per approved drawings and to the satisfaction of Engineer-in-Charge. . (The work is to be carried out by a specialized agency as approved by the Engineer)

2794

3440

9613402.41

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge

316.68

4313

1365850.02

... More
Providing & Fixing of Automatic bi-parting frameless glass sliding door (or equivalent), modular design including internal cover with operator dimensions 92mm H x 168mm W x 4200mm L for max. opening size of 3100mm(W) x 2400mm (H) & weight capacity for double leaf door is 2x120 Kg. Microprocessor Controlled unit will be self learning with adjustable parameters for opening & closing speed, hold open time, reversing when obstacles are encountered. Operator will have 65W DC brush-less Motor. Double leaf sliding glass door of 12 mm clear toughened glass as per approved drawing. Operator can be intgrated with Microwave sensor/Foot switch sensor/Handwave sensor/Mini sensor, Safety beam, Remote control to Set different modes & Automatic locking mechanism, Access card control system & Push button. The system shall have constant power supply 220V AC, 50/60Hz, for various opening sizes all complete as per design and instructions of Engineer- in-Charge. Product has 5 Year Warranty against any Manufacturing Defect. 1) The doors should be provided with electro-magnetic locks. Automatic control should be done by two infrared detectors, with a range of operating, control options and safety devices. 2) The panels will consist of 12mm toughened clear glass.(Clear span for Auto Sliding door (3.10 m wide x2.40m high)

5

412251

2061255

... More
Providing and fixing of Floor mounted SS-304 grade glass railing made up of 50mm dia top rail mounted on SS soild flat baluster of 50x12mm width to hold the top rail, Height of the railing shall be 1100mm from the floor to the top of the top rail, The baluster shall have infill of 10.89mm thick ( 5+0.89 SGP+5) laminated Toughened glass with height of 800mm high and length as per the layout plan connected to the baluster with SS 304 grade Dorma Glass links. The balusters shall be mounted on the floor with SS Grade 304 base plate of 100x 100mm x 8mm thick fixed on the floor with 4 No. M-8 grade GI threaded chemically grouted SS-304 grade fasteners. The work shall be done upto the satisfaction of the Engineer-in-Charge. (Please note that no welding of SS pipes will be allowed and work shall be done by a specialized agency on modular and component basis). All the material of Flat balustrade, Component and handrail should of ss 304 grade, Satin Finish.

1019.19

23500

23951012

... More
Providing and filling structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including Masking tape, as per the approved sealant design, within and all around the perimeter for holding glass complete as per direction of Architect/ Engineer-in-charge.

1565.8

250

391450

... More
Providing and fixing in position at required location as per drawing Sliding Folding Acoustic Partition of approved make MOVABLE WALL of required size of with HUPPE Variflex S 100U -Natural Anodized finish , Manual operation, Sound rating 52 db , VE:9, TE:1, Suspension 1P , MDF Surface with R Track on wall with required accesories , Huppe Track above the ceiling & sound baffling including overall installation and sound baffling etc. complete as per manufacturer's drawings and Specification with Transportation, Scaffolding all leads & Lifts to the complete satisfaction and as directed by Engineer in Charge/Project Architect (Detailed Specification is below)

638.06

8130

5187460.32

... More
The Acoustic Partition wall shall be 100mm thick panel as furnished and installed by an authorised representative of the fabricator and construction and finish with Class A rated materials

-

-

-

... More
Partitions shall be top supported, manually operated panels stacked in an area demarked in the plans. When closed, the openable wall shall provide a complete sound retardant barrier. No floor track shall be used. The suspension tracks are made from extruded anodized aluminium. The track housing shall utilize grooves and interlocking steel pins for positive alignment of adjacent track sections, and shall be reinforced overhead by drop rod brackets. Aluminum track housing shall include an integral nut slot to accept a hardened square nut for attaching each drop rod bracket to the top of the track. Central stacking system with a two wheeled nylon trolley made with the base Material of tempered steel shall be used as per approved stacking method.

-

-

-

... More
The panel trims will be exposed anodized aluminium trims of 15mm thickness. The Panels will be made from 12mm MDF boards and shall be 100mm thick and 1200mm maximum width, made to the appropriate acoustic rating and structural backing and mounted in full perimeter extruded aluminium frames with interlocking corner construction .The panel faces shall be finished with selected material. All panels shall be equal size as per module and as per the size of the opening in which to be installed. The panel shall be prefinished with 1.0 mm thick laminate t in charge on either sides as approved by the architec and filled with Rockwool sound absorption glass fibre minimum 60m thick.

-

-

-

... More
The top and bottom rail of each panel shall incorporate an extruded aluminium box section mechanical seal manually operated by a handle inserted in the panel stile, turning the handle through 45 degrees shall simultaneously extend or retract the top and bottom seals through an steel and spring mechanism which shall firmly hold the seals in the retracted or extended mode. Single crank type mechanisms shall activate floor and head seals.

-

-

-

... More
The end panel of the opening opposite to the closure shall be fitted with Bulb Seal and hollow extruded vinyl Seal, the Seal shall protrude 10mm beyond the end of the panel and shall be capable of compensating for minor variations in wall surface which it abuts.

-

-

-

... More
Providing & fixing of knobset made of stainless steel body, having provision of latch and bolt, 3 nos key set, inside push lock model ETL-101A, Finish SS/PB/AB make-ENOX or any equivalent (Lock should be releasable from out side in case of emergency) as per requirement for unisex toilet for PwD complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-incharge.

20

1145

22903.09

... More
Providing & Fixing of Wooden fire rated doors as per BS:476 Part- 20 & 22 & IS 3614 part-1 & part-2 for stability, integrity and thermal insulation 03 Criteria Wooden door with the following specification. Recommended fire door shall have doors tested at CBRI for maximum rating of 2hrs fully insulated 120 minutes wooden fire door, maximum thickens of 75mm, comprising of 100mm x 75mm hardwood internal timber frame work, with infill of 39mm thickness of 48 kg/m3, ceramic fiber blankets, coated with coating on both sides for insulation. The coated insulation shall be sandwiched between 12 mm thick, Calcium Silicate Boards on both sides as per the specifications. Approved Makes: Navair , Shakti

72

18127

1305144

... More
Supply & fixing of Panic bar Panic Bar single / double leaf panic exit devices. (Required For Fire Staircase Location Doors Only)as per direction of Engineer in Charge

24

3443

82632

... More
Supply & fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with SS Screws(Required For All Doors)as per direction of Engineer in Charge

96

874

83904

... More
Supply & fixing of Concealed door closers (Required For All Fire Doors Except Shaft Door)as per direction of Engineer in Charge

24

6054

145296

... More
Supply and fixing of Dorset, Hardwin, Becker Fire Solution make stainless steel 304 Grade H - Type pull handle of size 600mm long 22mm dia of approved make as per direction of Engineer in Charge.

24

4193

100632

... More
Providing and fixing Fiber cement board 75 mm thick drywall partition system, which include Galvalume grade 304 wall frame system, comrprising of 51x51mm Floor and Ceiling track profile, 0.5mm thick, having two equal flanges of 32mm, fixed to the floor and ceiling,in plumb with each other, with nylon sleeves and steel screws at 610mm; Vertical Galvalume studs of size 51mm, 0.5mm thick, having one flange of 42mm and another flange of 44mm and two equal lips of 5mm insert fixed into the track profiles at 610mm centres. 12mm thick Fibre Cement Board (confirming to IS 14862;Type-B, catagory-3) are then screw fixed on the either side of the framework, with 25mm Screw Fibre Cement screw, at 300mm centres.The joints of Fibre cement board are to be filled with jointing Compound. The rate shall include providing openings for windows glazing and doors with additional support, wherever required. all complete as per direction of Engineer-in-charg

2183.06

3039

6634324.2

... More
Providing and fixing Fiber cement board 100 mm thick drywall partition system, which include Galvalume grade 304 wall frame system, comrprising of 80x80mm Floor and Ceiling track profile, 0.5mm thick, having two equal flanges of 32mm, fixed to the floor and ceiling,in plumb with each other, with nylon sleeves and steel screws at 610mm; Vertical Galvalume studs of size 51mm, 0.5mm thick, having one flange of 42mm and another flange of 44mm and two equal lips of 5mm insert fixed into the track profiles at 610mm centres. 12mm thick Fibre Cement Board (confirming to IS 14862;Type-B, catagory-3) are then screw fixed on the either side of the framework, with 25mm Screw Fibre Cement screw, at 300mm centres.The joints of Fibre cement board are to be filled with jointing Compound. The rate shall include providing openings for windows glazing and doors with additional support, wherever required. all complete as per direction of Engineer-in-charg

1020.91

3873

3953984.43

... More
STEEL WORK

-

-

-

... More
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect

4492.8

506

2276652.27

... More
Structural steel work in angles, tees and flats, riveted or welded including cutting fixing all gusset plates, bolts, nuts, rivets, welding rod, etc. with hoisting and erecting in position :- For roof trusses, well curbs, plates and trussed girders, etc. of any span for buildings and bridges up to 15 m span.

57.23

9734

557100.23

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.

347.91

10798

3757023.74

... More
Structural steel work in compound built up girders or stanchions built up from two or more R.S. joists or channel section or plates and angles etc. riveted or welded, including cutting and fixing all lattices bars, stiffeners, gusset, plates, bolts nuts, rivets, welding rods, etc. complete with flange plates, heads sole plates, angle connections, etc. with hoisting and erecting in position.

158.92

7800

1239594.12

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:- Above 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position.

1177.65

11821

13922054.86

... More
Supplying and fixing rolling shutters of approved make, made of 80mm x 1.25mm M.S. Laths, interlocked together through their entire length, and jointed together, at the end by end locks, mounted on specially designed pipe shaft, with brackets, side guides 27.5 cm long wire spring grade No. 2 and arrangement for inside and outside locking, with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening; where rolling shutter is to be fixed).

22.19

2946

65381.81

... More
Providing & fixing ball bearing, for push and pull type rolling shutters, from 9.20 to 12 sqm area.

6

1324

7945.5

... More
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).

22.19

955

21201.75

... More
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)

754.95

375

283710.21

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

97.34

971

94599.89

... More
STRUCTURAL GLAZING

-

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.

-

-

-

... More
The laminated panel shall be assembled in the factory of AIS Glass/workshop of approved processor .“(Payment for fixing of glass Panels in the curtain structural glazing is included in cost of fixing of structural glazing “For payment, only the actual area of glass on face # 2 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. The properties of Glass of AIS Make are Visible Light Transmission (VLT) of 13%, External Reflection 16 %, Internal Reflection 19%, SHGC .31, U.Value 4.5 W/m2 Degree K

2097.03

2765

5799217.05

... More
Providing and supplying aluminum extruded tubular and other aluminum sections as per the architectural drawings and approved shopdraw ings , the aluminum quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminum frame work. Nothing extra shall be paid on this account). The weight of aluminum extruded section shall be taken for purpose of payment.

35834.09

373

13401682.1

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:

2097.03

2204

4623909.06

... More
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including

-

-

-

... More
(b) Fabricating and supplying serrated M.S. hot dip galvanised / aluminum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.

-

-

-

... More
(d) Providing and fixing in position flashings of solid aluminum sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminum grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the aproved shop drawings and as directed by the engineering-Charge.

-

-

-

... More
Note:- 1. The cost of providing extruded aluminum frames, shadow boxes, extruded aluminum section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & echnologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025.

-

-

-

... More
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330- 10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

-

-

-

... More
ROOFING

-

-

-

... More
Supplying, Fitting and Fixing 12 mm thick Clear Solid polycarbonate sheet of approved make and brand conforming to IS:14443-1997 hand having 50 micron UV protection layer under co-extrusion technology both side, fire rating being B-s1 as per EN1350-1 certification , fitted and fixed with 60 mm wide aluminium channel section top and bottom member in dry glaze sandwitch system (unit weight of top & Bottom member :0375 kg/m & 0.69 kg/m) of approved brand & profile , EPDM quality rubber gasket anti dust tape, end closer " C " Channel and 75mm long selftaping screws being drilled through the centre leg of the bottom section with nuts placed at 300mm apart without anyway punching the polycarbonate sheet, EPDM Washer 16mm dia & 3mm thick washer etc. complete strictly as per manufacturere specification and direction of Engineer in charge .The Complete roofing shall be grouted with structural weather proof silicon sealant to form a water proof surface complete including cost of all material, labour, machinery, T&P, curing, all leads, lifts, scaffolding, sampling, testing ,Electricity and water arrangements complete in all respects as per drawings, requirements, specification & as directed by the Engineer-in-charge/Consultant. (M.S. Roofing structure shall be paid in respective items ) (Payment to be made on areaof finished work)

1589.2

5097

8101337.51

... More
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

2548.72

71

181967.64

... More
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.

-

-

-

... More
Ground Floor

26

110

2862.91

... More
Terrac Floor

8

110

880.89

... More
Bottom Khurra on ground 1.2m x 0.6m consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3

26

850

22103.44

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 2.50 kgf / cm²) conforming to IS : 4985, including jointing with seal ring (i) Single socketed pipes. (i) U-PVC pipes (working pressure 2.5 kgf. / sqcm) Single socketed pipe 110 mm dia.

73.04

200

14620.05

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 2.50 kgf / cm²) conforming to IS : 4985, including jointing with seal ring (i) Single socketed pipes. (i) U-PVC pipes (working pressure 2.5 kgf. / sqcm) Single socketed pipe 160 mm dia.

333.04

790

263143.23

... More
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (a) UPVC 110 mm bend

16

142

2275.56

... More
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.

32

153

4896

... More
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.

8

88

707.95

... More
Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge..

24

110

2640

... More
Providing & Fixing in position S.S Grade 304 clamps made out of S.S flat Sheet not less than 5 mm of the approved design for fixing upvc. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. S.S. Holder bats clamps for 110mm uPVC pipes

59

368

21754.78

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning I self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self- centering arrangement that freely rotates I moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- charge. (Material shall conform to ASTM 6063).

-

-

-

... More
Floor Joint of 100 mm gap

1510.4

4370

6600448

... More
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning I centering arrangement and support plates as per ASTM 8221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to comer application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063).

-

-

-

... More
Wall Joint of 100 mm gap

602

541

325682

... More
Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.

602

541

325682

... More
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering arrangement that freely rotates I moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063).

-

-

-

... More
Roof Joint of 100 mm gap

302.08

1003

302986.24

... More
WATER PROOFING

-

-

-

... More
Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:

-

-

-

... More
(a) Applying a slurry cost of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment.

-

-

-

... More
(b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer.

6571.41

477

3136110.09

... More
Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of Elastobar and Zycoprime/Equivalent after application of Zycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brushable. Apply the paste on surface with brush. Leave the surace for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementatios membrane using mixture of 1 Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed.

13544.8

445

6035974.26

... More
Supply & Fixing Fiber Glass Coated Mesh with thickness of 45 Gsm for the water proofing of roof terraces, bathrooms , Water tanks, etc. The surface to be levelled, finished, made smooth before fixing of Fiber Glass Mesh, complete in all respect as per manufactures specification and as per directions of Engineer-in-Charge.

1611.39

125

202014.32

... More
Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge.

6571.41

589

3870569.07

... More
Waterproofing of wet areas ( Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build-up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects.

1611.39

531

856455.86

... More
Providing and applying injection grouting using cement slurry admixed with Fosroc Chemical Conplast WL or any other equivalent compound @ 300 ml/ Bag of cement through the uPVC nozzles ( 12mm dia uPVC/ Plastic Nozzles - 4" to 9" long @ 5 No: / Sqm of area) , provided into the cracks/ honeycombed areas using 140 PSI hand operated Grouting Pump under pressure till the refusal,doing final Cement slurry Grouting (after 28 Days),, finally cutting & sealing of Nozzle. including all labour, supervision, tools and tackles and transportation etc. complete as per direction of Enginner -in- charge.

50

1133

56678.3

... More
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick

9999.61

563

5634779.62

... More
Providing and laying autoclaved aerated cement blocks masonry with 100mm thick AAC blocks in super structure above plinth level in cement mortar 1:4 (1 cement : 4 fine sand ) The rate includes providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of masonry work.

402.85

1550

624716.57

... More
ROAD WORK AND PARKING

-

-

-

... More
Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications.

20896.2

6

132084.88

... More
Construction of granular sub-base by providing material as per grading-III ( Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications

3134.43

2071

6492335.1

... More
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications

4701.65

2113

9936431.84

... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85kg/sqm complete as per technical clause 502 of MORT&H specifications

17419.8

57

1007909.63

... More
Providing and applying tack coat with bitumen emulsion RS using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications

17419.8

17

308678.86

... More
Providing and laying dense graded bituminous macadam 50mm to 75mm thick with Continuous type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.5%, laying with a Paver Finisher Mechanical to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 505 of MORT&H specifications

870.99

9639

8395506.27

... More
Providing and applying tack coat with bitumen emulsion RS using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications

17419.8

17

308678.86

... More
Providing and laying bituminous concrete 30mm to 45mm thick with Continuous type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.4%, laying with a Paver Finisher Mechanical to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of MORT&H specifications

522.59

11364

5938982.93

... More
Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications

1741.98

649

1131697.94

... More
Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type

452.19

4365

1973869.25

... More
Cement concrete 1:3:6 with stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type

17.35

4651

80705.78

... More
Providing and laying Granite cobble stone block 100x100x75mm interlocking size and design / shape laid in Dark fast Colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge

2781.12

3250

9038640

... More
Brick ballast well or over burnt, broken and screened through a 32mm x 32mm square mesh screen laid consolidated and rammed to a finished thickness of 75mm as above.

34.7

124

4313.41

... More
Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications

3485.1

376

1312800.44

... More
Precast Cement Concrete Channel Providing and laying factory made rubber moulded smooth finish cement concrete Channel M-20 grade 300mm wide and 75mm thick made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications

1259.8

246

310206.29

... More
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

8242.26

69

573092.68

... More
Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminum Composite material (ACM) sheeting having aluminum skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminum alloy rivets @ 200 mm c/c to back Support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 .

-

-

-

... More
Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012

5

4274

21373.83

... More
Mandatory sign board 900mm circular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. Fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012 .

-

-

-

... More
Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012

6

5445

32673.88

... More
Informatory sign board 600x600mm square as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. with retro reflective high intensity Microprismatic grade sheeting fixed over 3mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012 .

8

4059

32475.87

... More
Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012

-

-

-

... More
Providing and installation of solar cateye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cateye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 4 mm. The body of the solar cateye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280.

500

1236

618019.97

... More
Providing and fixing of Standard Metal Delineator as per IRC 79:2019 consisting of retro reflective area in white color using full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67 2012 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI table specification. The delineator shall be painted with only black color powder coat of minimum 40 microns thickness, on top of which retro reflective sheeting only in white colour shall be pasted on both sides. The structure shall have height not less than 800 mm above the ground, width not less than 100 mm and shall extend not more than 300mm below the ground while being installed. The delineator shall have grooves across the length to make the reflective sheets vandal-proof. The delineator is meant for application on gaps in median, traffic islands, dangerous bends, roundabouts, narrow bridges etc. or as desired by site engineer.

200

1238

247625.18

... More
Public Health Work

-

-

-

... More
CIVIL WORKS UNDER PUBLIC HEALTH

-

-

-

... More
EARTH WORK

-

-

-

... More
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.

1774.39

35

63557.05

... More
Earth filling

-

-

-

... More
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres

532.32

291

155340.92

... More
Carriage of Earth,Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast, Stone boulders, Kankar and building rubbish, Earth. 5.0 km

1242.08

91

113043.7

... More
Sand filling under floor and in wells of bridge foundation including handling withing 100 metres

116.29

1058

123128.69

... More
CENTERING & SHUTTERING

-

-

-

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

143.6

221

31769.48

... More
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.

-

-

-

... More
Basement+Foundations

2272.92

469

1067958.61

... More
Centring and shuttering for columns (Square or rectangular or poly gonal in plain)

-

-

-

... More
Ground Floor

61

545

33288.49

... More
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels.

-

-

-

... More
Basement+Foundations

274.96

443

121953.35

... More
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.

-

-

-

... More
Basement+Foundations

691.19

560

387385.8

... More
Centring and shuttering for stair cases with sloping soffits including risers and stringers.

-

-

-

... More
Basement+Foundations

16.65

469

7823.19

... More
CEMENT CONCRETE

-

-

-

... More
Cement concrete 1:2:4 with stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type

-

-

-

... More
Basement+ Footings

87.68

4972

435995.47

... More
REINFORCEMENT WORK

-

-

-

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth

647.47

5979

3871653.76

... More
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )

647.47

358

231917.24

... More
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)

647.47

92

60025.64

... More
Extra for providing and mixing water proofing material in cement plaster work @ 1 kg per 50 kg of cement.

4532.29

72

329458.91

... More
STEEL REINFORCEMENT

-

-

-

... More
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete

-

-

-

... More
Basement+Foundation

1133.07

6919

7840167.08

... More
BRICK WORK

-

-

-

... More
Pulverized Fly Ash - Lime Bricks as per class- 12.5 of IS:12894-2002 laid in cement sand mortar 1:4 in foundation and plinth (laying shall be done as per PWD specifications).

59.14

5155

304921.04

... More
Pulverized Fly Ash - Lime Bricks as per class- 12.5 of IS:12894-2002 laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level (laying shall be done as per PWD specifications).

-

-

-

... More
Ground Floor

9.27

5338

49503.26

... More
FLOORING WORK

-

-

-

... More
Floating coat of 1.5mm thick neat cement laid in one operation to the topping.

259.83

30

7938.2

... More
Conglomerate floor 50mm thick cement concrete topping 1:2:4 ( Using mechanical mixer for mixing of materials).

259.83

364

94710.89

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile cement based adhesive conforming to IS: 15477, in average 6 mm thickness or as directed by engineer in charge, including grouting of joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.

-

-

-

... More
Glazed Vitrified tiles Matt/Antiskid finish of size

-

-

-

... More
Size of Tile 600 x 1200 mm thick

2660.89

2150

5720917.8

... More
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.

-

-

-

... More
Size 800x800mm thick

1312.46

2248

2950413.35

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling grouting and finishing complete as per direction of Engineer-in-charge.

-

-

-

... More
Size 800x800 mm.

1312.46

147

193574.94

... More
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

981.6

736

722850.49

... More
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing

-

-

-

... More
Basement Floor+Ground Floor

476.33

1406

669927.56

... More
FINISHING WORK

-

-

-

... More
12.5 mm thick cement plaster 1:5

234.25

190

44666.85

... More
20mm thick cement plaster 1:5 in two coat work

37.03

260

9636.26

... More
Plastering on underside of ceiling 10 mm thick cement plaster 1:4.

202.48

184

37329.72

... More
Providing and fixing chicken mesh on brick work and RCC work junction made of galvanized low carbon wire, annealed wire of diameter 0.6 to 2.0mm distance between the faces of the hexagon 13 to 15mm complete in all respect.

40.69

197

8016.45

... More
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish.

473.76

84

39928.32

... More
Applying priming coat with metal primer on new steel or iron work including preparation of surface. With special quality paint

91.89

25

2323.35

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. With special quality paint

91.89

69

6389.2

... More
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm

473.76

105

49910.41

... More
JOINERY WORK

-

-

-

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :For fixed portion and chaukhats

27

370

10012.46

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required.

1.35

387

523.38

... More
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.

28.35

71

2030.94

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item)

-

-

-

... More
Float glass panes of 5 mm thickness

2.7

1090

2944.01

... More
Providing and fixing Stainless Steel sliding door bolts of Satin finish, of Grade SS 304, with SS nuts and screws etc. including labour , Material & equipment or machinery required complete in all respect to the satisfaction of Engineer-in-charge/Architect.

-

-

-

... More
300x16 mm

8

1103

8824

... More
Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

8

90

724.81

... More
Providing & fixing 6" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

8

250

2005.86

... More
Providing & fixing fly proof wire mesh to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (144 hole per square inch).

1.75

1041

1821.75

... More
Providing and filling structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including Masking tape, as per the approved sealant design, within and all around the perimeter for holding glass complete as per direction of Architect/ Engineer-in-charge.

17.4

250

4350

... More
STEEL WORK

-

-

-

... More
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect

81

506

41045.41

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.

1.13

9628

10919.27

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-

-

-

-

... More
Above 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position.

20.56

11810

242818

... More
ROOFING

-

-

-

... More
Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

-

-

-

... More
0.60 mm (+ 0.05 %) thick

101.34

750

76014.32

... More
Providing and fixing Gutter 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge.

26.7

1424

38029.66

... More
Ridges and valleys 45 cm overall, in plain G.I. Sheet 0.80mm fixed with galvanzed iron J. and L. hooks 10mm diameter, G.I. Limpet and bitumen washers complete

13.35

438

5850.72

... More
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

58.72

68

4021

... More
WATER PROOFING

-

-

-

... More
Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of Elastobar and Zycoprime/Equivalent after application of Zycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brushable. Apply the paste on surface with brush. Leave the surace for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementatios membrane using mixture of 1 Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed.

839.16

445

373953.95

... More
Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge.

264.15

589

155584.7

... More
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick

1103.31

563

621713.49

... More
PUBLIC HEALTH WORKS

-

-

-

... More
SANITARY INSTALLATION

-

-

-

... More
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.

-

-

-

... More
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.

170

10395

1767309.46

... More
Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer-incharge) complete in all respect.

170

9870

1677941.06

... More
Providing and fixing C.P. brass 32mm long bend complete

170

799

135933.11

... More
Providing and fixing jet spray with 2'-6" long PVC pipe.

-

-

-

... More
With C.P. Brass nut

170

501

85249.22

... More
Providing and fixing in position CP Brass Grab Bar of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.

16

1761

28183.23

... More
Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.

-

-

-

... More
35mm dia 600mm (24”) long

20

1389

27791.33

... More
35mm dia 1200mm (48”) long

40

2809

112387.38

... More
Foldable U Type 762mm long

20

6652

133057.05

... More
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.

-

-

-

... More
Size 560mm x 450mm (Under counter oval)

210

4526

950646.8

... More
Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect.

-

-

-

... More
C.P. brass wall mixer without telephonic shower

210

3049

640475.33

... More
Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge)

5

2637

13189.82

... More
Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-incharge) complete in all respect.

340

1182

401889.18

... More
Providing and fixing in position vitreous Chinaware white Senso urinal size 37 x 39 x 61 cm of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm complete in all respect.

130

20391

2650900.98

... More
Providing and fixing in position Sensor electric for urinal of approved make (to the approval of Engineer-in-charge) complete in all respect.

130

6819

886509.72

... More
Providing and fixing partition for different type of urinals.

-

-

-

... More
Toughned Glass Partition 8mm thickness size 450 x 900 mm C/S

100

6347

634733.75

... More
Providing and fixing Stainless steel health faucet complete in all respect.

170

1199

203989.21

... More
Extra for providing and fixing G.I. 40mm waste pipe including elbow, reducer etc complete in all respect.

16

490

7854.9

... More
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.

-

-

-

... More
Rectangular Sink with Deluxe Border Single Bowl Overall Size 555 mm x 475mm x 200 mm

16

6827

109243.74

... More
Providing & fixing in position C.P brass Sink mixer swivel spout (Wall mounted) of approved make (to the approval of Engineer-incharge) complete in all respect.

32

3117

99753.81

... More
Providing and Fixing in position Glass shower enclosure L shaped 8mm thick with chrome finish with sliding door and entry from the front of approved make (to the approval of Engineerin- charge) complete in all respect.

12

3117

37407.68

... More
1200x1000 x 1950mm

-

-

-

... More
Providing and fixing in position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect.

12

1079

12958.05

... More
Providing and Fixing diverter Aquamax Exposed Part Kit of Thermostatic Shower Mixer with 2-way diverter of Approved reputed make (Suitable for ALD-681) and Aquamax Concealed Body of Thermostatic Shower Mixer with 2-way diverter of reputed including all material and labour making good walls to the complete satisfaction of Engineer in Charge.

12

17351

208218.6

... More
Providing and fixing in position paper holders of approved make (to the approval of Engineerin- charge ) fixed in to wall with C.P brass screws complete in all respect.

-

-

-

... More
C.P. brass toilet paper holder

170

1141

194138.98

... More
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.

-

-

-

... More
C.P. brass towel Rails size 15mm dia 610mm long

32

1621

51882.77

... More
C.P brass towel ring

70

959

67181.7

... More
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect (as required by the Engineer-in- Charge)

-

-

-

... More
Size 600mmx450mm

2

1263

2526.29

... More
Size 1500mmx600mm or any other size

291.38

3238

943741.06

... More
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge ) complete in all respect.

-

-

-

... More
C.P. brass Bib cock long nose/ long body with flange

10

1214

12146.86

... More
C.P. brass Bib cock Short Body

140

552

77284.76

... More
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.

-

-

-

... More
C.P.brass 15mm Concealed stop cock with flange.

510

1268

646891.14

... More
C.P.brass 15mm Angle valve without flange

300

870

261057.3

... More
Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect.

-

-

-

... More
C.P. brass liquid soap container

90

1954

175881.83

... More
Providing and fixing in position CCT-SFC-127 Square stainless steel Cockroach Traps of Approved reputed make square size 127x127 mm with stainless steel floor drain grating, inner filter, outer filter, rim etc. complete including cast of cutting and making good the walls floors at all heights, levels, including cost of all material, lead, lifts and other required material such as concrete/mortar etc. as per directions of Engineer-in-charge.

290

1335

387251.5

... More
Providing and fixing modular toilet cubicles of Approved reputed make as per manufaturer's standard specifications.All intermediate panels, pilasters, doors shall be made up of Solid Compact Laminate (Phenolic Core Board) 12 mm thick as per IS 2046 based on thermosetting resins, homogeneously reinforced with cellulose fibers making cubicles impervious to Water, resistant to Fire, etc. Compact laminate should be Greenguard and IGBC certified. Hardware and Fixing All accessories shall be of 304 grade including all hardware/fittings. The pilaster are anchored to the flooring using adjustable SS legs.The SS SQUARE top rail shall be fixed on the top of the pilasters. Accessories Standard accessories include SS Hinges, SS Door knob, SS thumb turn indicator, SS coat hook, SS SQUARE top rail and SS channels (All accessories in SS 304 grade) SS legs in SS 316 Grade. Titan SS Series Cubicles MERINO-BESCO make or equivalent 12mm thick: Std Sizes (W x D x H)- 1000 mm x 1500 mm x 2100 mm, ( Height is including 130 mm gap from bottom) Door Size- 610 mm x 1905 mm.

120

65000

7800000

... More
Providing and Fixing in Position Hand Dyer of Approved reputed make including Fixing in Position complete in all Respects to the complete satisfaction of Architect/Engineering-in charge.

40

11561

462440

... More
Toilet Counter (Corian Top)

95.4

30004

2862433.12

... More
Providing and fixing vanity counters with 12 mm thick ISO-19712 certified Acrylic solid surface of approved make in white and grey with spickle shade in approve design , with properties like anti-bacterial antifungal, heavy duty scratch resistant & stain resistant, impact resistant, insulative & non conductive, Green Guard certified, Fire rating as per standard EN 135 -1-1b surface spread of flame and having minimum Specific Gravity 1.65 g/cm3 properties. Acrylic solid surface sheets to be cut, pasted and finished in approved shade , as per approved design by the Engineer in charge. Counter minimum width 600mm seamlessly integrated with ready-made oval bowls in approved color with minimum size 571 mmx 418mm x 178 mm & front fascia of minimum 200mm and back splash of minimum 100mm to complete the profile. The spacing between two wash basin shall be minimum of 750mm center to center or specified other wise , should be placed symmetrically in the vanity counters.

-

-

-

... More
This counter should be fixed over metal supporting structure of Toilet Counter with all mechanical fixtures as per specification, drawings and guideline or as directed by Engineer in charge.The quoted rates shall include material cost with wastages, fabrication & installation of counter at site, cost of silicon & approved adhesives, chamfering of edges, flushing of joints and final finishing as per directions of the Engineer-In-charge. The plan area (horizontal area deducting washbasin opening ) will be measured for payment.

-

-

-

... More
Providing metal supporting structure for vanity counters made of 35 x 35 x 2.6 mm square hollow section tube with all necessary mechanical fixtures like fasteners screws etc. duly painted with epoxy primer and two or more coats of polyuthrene paint complete as per direction of the Engineer in charge.

-

-

-

... More
Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of E.D.C manufacture or oy any other reputed firm including cutting, jointing, wastage, but excluding cost of lead jointing.

-

-

-

... More
Type B

-

-

-

... More
50mm o/d SWR UPVC pipe line laid complete

505.69

208

105182.9

... More
60mm o/d SWR UPVC pipe line laid complete

793.1

307

243482.93

... More
110mm o/d SWR UPVC pipe line laid complete

1641.65

396

650352.22

... More
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.

-

-

-

... More
M.S. Holder bats clamps for 100mm i/d SWR UPVC pipes

1094.43

217

237687.67

... More
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.

-

-

-

... More
For 110mm o/d pipes

-

-

-

... More
End cap

50

73

3674.08

... More
Single Junction With Door

150

236

35448.17

... More
Bend Plain

60

162

9753.94

50

45

2269.77

... More
Collar

40

111

4443.66

... More
Single Y-junction with Door

30

306

9193.58

... More
110mm x75mm reducer tee

25

198

4954.08

... More
Cross tee/Double tee

10

256

2568.43

... More
Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

16

1013

16215.47

... More
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.

-

-

-

... More
100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm

16

2466

39465.63

... More
Core cutting in RCC beams, slabs, side walls etc. for making holes in RCC beam circular in shape having dia. 120 to 150mm using core cutting tool, including removing all debris etc. complete as per direction of Engineer

450

490

220758.87

... More
INTERNAL WATER SUPPLY

-

-

-

... More
Providing and fixing in position automatic brass Ball Cock in tanks.

-

-

-

... More
Plastic Ball Cock with rod and Plastic Ball

-

-

-

... More
50mm i/d

13

1673

21752.97

... More
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.

-

-

-

... More
CPVC SDR 11 Pipe & fitting 16mm o/d

850

188

160039.29

... More
SDR 11 CPVC pipes & fittings 20mm o/d

650

233

151574.95

... More
INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.

-

-

-

... More
25mm o/d

1200

238

286594.14

... More
32mm o/d

300

324

97239.1

... More
40mm o/d

250

398

99626.86

... More
50mm o/d

350

577

201983.87

... More
65mm i/d

150

1006

150905.97

... More
Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.

-

-

-

... More
20mm i/d Gun Metal peet valve heavy pattern.

20

592

11855.46

... More
25mm i/d Gun Metal peet valve heavy pattern.

15

814

12214.7

... More
32mm i/d Gun Metal peet valve heavy pattern.

10

1245

12451.63

... More
40mm i/d Gun Metal peet valve heavy pattern.

8

1648

13185.86

... More
50mm i/d Gun Metal peet valve heavy pattern.

9

2536

22825.95

... More
65mm i/d Gun Metal peet valve heavy pattern.

10

3993

39931.65

... More
Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects.

4

395

1581.56

... More
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.

-

-

-

... More
Through wall 22.86 cm thick

450

251

113270.74

... More
Cutting holes upto 23cm square for pipes in floor and roofs of cement concrete, reinforced concrete or reinforced brick work and making good the same & finishing according to existing finish where required.

-

-

-

... More
Through floor or roof 11.5cm thick

290

106

30957.83

... More
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size 0.6 m. x 0.6 m.

2

5589

11179.66

... More
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks.

80000

11

910224

... More
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. G.I. tank nipple 20mm i/d

13

124

1617.44

... More
Providing, Supllying , installing, commissioning and testing Non Self priming, Multi Stage, Horizontal Centrifugal Pumping Set (monoblock booster pumps) with Electric controller level indicator and Auto cutoff, Switch etc. gate valve and non return valve with other accessories complete in all respect

4

98707

394830.03

... More
Discharge-450 LPM

-

-

-

... More
Head-20 mtr

-

-

-

-

-

-

... More
EXTERNAL SEWER

-

-

-

... More
Cement concrete 1:5:10 with brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type

76.8

3400

261173.61

... More
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.

-

-

-

... More
160mm o/d pipe

40

793

31731.42

... More
200mm o/d pipe

200

1243

248626

... More
250mm o/d pipe

307

1906

585398.35

... More
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 63.464 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.

-

-

-

... More
Inside size 75x120 cm with depth 120 cm between bottom of top slab and invert ( with MH cover & frame Medium duty)

30

37041

1111230

... More
Extra payable for every 0.30 m additional depth of manhole chamber in item 29.84 upto 1.80 m increase in depth.

-

-

-

... More
Inside size 75x120 cm

30

5600

168012.18

... More
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.

-

-

-

... More
600mm x 900mm inside with 455mm x 455mm cover and frame medium duty double seal

10

8970

89705.53

... More
Extra for every 0.30 metre depth of inspection chamber.

-

-

-

... More
600mm x 900mm inside

10

1842

18425.72

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.

-

-

-

... More
For pipes 100 to 250 mm Diametre

8

353

2831.81

... More
Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda

-

-

-

... More
Sewer connections upto 300 mm id

1

6384

6384.21

... More
Foot Rest for Manhole

200

220

44036.3

... More
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.

-

-

-

... More
Providing and fixing RCC manhole covers only

20

1169

23387.7

... More
560mm i/d RCC man hole cover only as per ISI

-

-

-

... More
Heavy duty

-

-

-

... More
STORM WATER PIPES

-

-

-

... More
Cement concrete 1:5:10 with brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type

144

3400

489700.51

... More
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.

-

-

-

... More
150mm i/d pipes

50

793

39664.27

... More
200mm i/d pipes

900

1243

1118817

... More
250mm o/d pipe

250

1906

476708.75

... More
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 63.464 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.

-

-

-

... More
Inside size 75x120 cm with depth 120 cm between bottom of top slab and invert ( with MH cover & frame Medium duty)

20

37041

740820

... More
Extra payable for every 0.30 m additional depth of manhole chamber in item 29.84 upto 1.80 m increase in depth.

-

-

-

... More
Inside size 75x120 cm

20

5600

112008.12

... More
Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No. 10.3) in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.74) complete and to the requirement of the Engineer-In-Charge.

-

-

-

... More
Single Road Gully chamber

-

-

-

... More
Size 610mm x 457mm x 800mm

40

6300

252039.34

... More
Size 610mm x 457mm x 1105mm

20

7765

155306.97

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.

-

-

-

... More
For pipes 100 to 250 mm Diametre

10

353

3539.76

... More
Providing, lowering precast concrete NP-2 Plain end pipes and collar with reinforcement, in trenches to correct gradient and alignment, cutting of reinforcement cement concrete plain end pipes, stringing 1n trenches. jointing ends and fixing collar with cement mortar 1.2 as per IS 458:2003 into trenches for all depths and laying out same to correct alignment, gradients, levels etc. complete in all respect.

-

-

-

... More
RCC Pipe NP-2

-

-

-

... More
above 150 mm but upto 300 mm inside diameter

503

1527

768370.23

... More
above 300 mm but upto 600 mm inside diameter

376

2844

1069513.2

... More
EXTERNAL WATER SUPPLY PIPELINE

-

-

-

... More
Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects.

-

-

-

... More
Earth work upto 1.5 m. Depth

-

-

-

... More
All classes of soil except rocky

75

178

13355.48

... More
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.

-

-

-

... More
CPVC SChd 40pipe & Schd 80 fittings ( 100 mm i/d)

134

1778

238361.03

... More
CPVC SChd 40pipe & Schd 80 fittings ( 62.5 mm i/d)

1049

996

1045688.07

... More
CPVC SDR 11 pipes & fittings 0/d 40mm

155

391

60615.81

... More
Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.

-

-

-

... More
100mm i/d Gun Metal peet valve heavy pattern.

10

11727

117274.04

... More
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

-

-

-

... More
Size 0.9 m. x 0.9 m.

10

8247

82475.04

... More
TUBEWELL

-

-

-

... More
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.

-

-

-

... More
Boring with 300mm id Housing Pipe

-

-

-

... More
Upto 150 m depth BGL.

325

954

310302.37

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.

-

-

-

... More
200 mm nominal size dia having minimum wall thickness 5.40 mm

275

1905

524040.66

... More
Supplying,assembling, loweringandfixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs,conforming to IS:12818 , including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.

-

-

-

... More
200 mm nominal size dia.

50

2702

135134.03

... More
Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect.

-

-

-

... More
200mm internal diameter

2

5138

10277.74

... More
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect

-

-

-

... More
200mm internal dia

6

733

4403.9

... More
Supplying & fixing of M.S Clamp suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.

-

-

-

... More
200 mm dia

1

778

778.2

... More
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.

-

-

-

... More
200mm internal diameter (weight 41.6 kg per metre) 8.0 mm thickness

1

3007

3007.13

... More
Providing and installing 100 mm dia delivery main from Tubwell to duck foot bend including cost of C.I /D.F pipes, D/F sluice valves, D/F NRV & Specials as C.I. Bends, Tail Piece Tees etc. inside the pump chamber as per standard design complete in all respects. (As per Department( DWSS) approved Rate )

1

48200

48200

... More
Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-incharge.

25

1718

42972.79

... More
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe)

30

778

23345.98

... More
PUMPING MACHINERY

-

-

-

... More
Providing installing commissining and testing of submesible pumping set with 10 BHP electric meter capable of pumping 350 Lt./Hours to a head of 42 mt along with 40 mm i/d G.I pipe B class = 60 mtr. with flanged nuts and bolts. subermersible cable 4 sqm three core =120mtr. from tubewell to main switch complete in all respects.

-

-

-

... More
Head = 42 mtr.

-

-

-

... More
Discharge = 40000 LPH

2

175763

351526.18

... More
Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of O to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in fal respect. of Approved reputed make .

-

-

-

... More
10 HP Motor

1

32774

32774.5

... More
For Pump House/U.G Tank

-

-

-

... More
Supply, assembly, erection, testing and commissioning of pumping system comprising the following:

1

74883

74883.18

... More
Vertical centrifugal pumps with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor with class F insulation suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C with IE-3 efficiency class. supply with 100 mm dia pressure gauges with ball valve including MS skid and mounting of the pumps on the skid and foundation as per manufacturer's recommendation etc. complete as required. (Motor to be of the same make as the pump). Motor shall be of energy efficient type meeting the latest BIS/ECBC guide lines.(Pumps will be with positive suction.) Note: electrical panel for cyclic operation not required.

-

-

-

... More
Flow rate of each pump : 300LPM

-

-

-

... More
Head : 30 Mts

-

-

-

... More
Required for : Filter Feed Pump

-

-

-

... More
Location : Pump Room

-

-

-

... More
Maximum Motor rating: 2 HP

-

-

-

... More
(1 set of 2 pumps, 1 Working + 1 Standby)

-

-

-

... More
Drainage Sump Pump : (2 H.P)

1

61511

61511.18

... More
Supply, assembly, erection, testing and commissioning of submersible drainage type pumps with non-clog, free flow suitable for solid handling capacity as mentioned below and suitable to handle pump room drainage having the following capacities, complete with 3 phase squirrel cage submersible motor of required HP and suitable for operation at 415 ± 10% volts, 3 phase, 50 Hz. A.C supply with IE-2 efficiency class, cooled by surrounding liquid, i/c submersible cable upto main panel, Electrical control panel with sequential DOL starter & MPCB as incommer having the necessary accessories and safety devices , dry running preventor, G.I. guide pulling chain, all the necessary piping and accessories, valves, delivery header etc. as required complete in all respects. The quoted rates shall also include a three level sensor, controller and level indication (low, mid and high) system with a sounder for high level. The pumps will start as follows: (a) At mid level pump 1 will start. (b) At high level both pumps shall start and there will be a sounder alarm . The item will include any hardware and software required for integration with BMS. Motor shall be of energy efficient type meeting the latest BIS/ECBC guide lines. Each set consists of 2 nos pumps

-

-

-

... More
The above installation shall be complete with sump pump lifting assembly, float switch , sequential starter arrangement, cabling, ready made electro – galvanized MS lifting chain, GI pipe header complete with discharge manifold, flanges, tee, elbow etc. complete including GI pipe upto the top of sump and including GI union. Header shall be sized for both pump working under delivery velocity of 1.5 m/sec.

-

-

-

... More
Flow rate : 3 LPS

-

-

-

... More
Head : 10 Mts

-

-

-

... More
Solid Handling : 10-15 MM

-

-

-

... More
Purpose : Pump Room drainage

-

-

-

... More
MOC : CI Impeller & Shaft

-

-

-

... More
Maximum Motor rating : 1 HP

-

-

-

... More
Power Supply : Single Phase

-

-

-

... More
Providing, fixing, testing and commissioning of motorized butterfly valve of following dia for filling of Over Head Water tank complete with high and low level control switches to control the valve. The level controllers shall be installed in overhead tanks. The level switch with manual and auto closing arrangement for the valve when water level is high (Top Water Level) in over head tank and open the valve when over head water tank level is low (30% of storage capacity). The system should be complete in all respects with accessories, 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in weather proof casing etc.

-

-

-

... More
65mm nominal bore

3

14261

42783.7

... More
32mm nominal bore

4

11463

45852.57

... More
25mm nominal bore

9

10445

94006.8

... More
20mm nominal bore

90

8178

736078.23

... More
Annunciation And Indication Panel with Level Controller

-

-

-

... More
Supplying, installing, testing and commissioning of annunciation and indication panel with interlocking arrangement complete in accordance to specification with level controller (1 No. Fire Tank, 1 No. Raw and 1 No. Treated water tanks :4 Nos. level controller), etc with control cabling from field to MCC Panel as required. Each controller shall have 3 no. SS 304 probes.

1

9658

9658.32

... More
MULTIGRADE SAND FILTER (For Domestic Water)

1

61216

61216.21

... More
Supply, installation, testing & commissioning of vertical self supporting Dual Media Filter (DMF) fabricated using MS 6 mm thick plate for shell & 8 mm thick plate from dish end, with sand blasting (SA 2.5), epoxy primer & epoxy painting inside and enamel painting outside as per IS : 2825/ ASME code(calculation data to be submitted), complete with pressure gauges at inlet & outlet, sample cock, face piping (GI, C Class) with CI butterfly valves and all accessories, with initial charge of filter media for Dual media filter with multi grade quartz sand & anthracite, testing and commissioning complete as per site requirement.

-

-

-

... More
Filter for Domestic Water services.

-

-

-

... More
Filteration Rate 18000L/Sqm/Hr

-

-

-

... More
Working pressure 3 Kg/Sq.cm

-

-

-

... More
Capacity : 2.5 LPS

-

-

-

... More
Location : Pump Room

-

-

-

... More
ACTIVATED CARBON FILTER (Domestic)

1

56889

56889.98

... More
Supply, assembly, erection, testing & commissing of vertical Activated Carbon filter fabricated using MS 6 mm thick plate for shell & 8 mm thick plate from dish end, with sand blasting (SA 2.5), epoxy primer & epoxy painting inside and enamel painting outside as per IS : 2825 / ASME code(calculation data to be submitted), complete with pressure gauges at inlet & outlet, sample cock with initial charge of filter media activated carbon, face piping (GI, C Class), diaphragm/ball/non-return valves, accessories, testing and commissioning of any under drainage system complete as per site requirement. (Tested to 10 kg/sq cm)

-

-

-

... More
Filter for Domestic Water services.

-

-

-

... More
Filteration Rate 18000L/Sqm/Hr

-

-

-

... More
Working pressure 3 Kg/Sq.cm

-

-

-

... More
Capacity : 2.5 LPS

-

-

-

... More
Location : Pump Room

-

-

-

... More
CHLORINATOR FOR CHLORINATION

1

15812

15812.39

... More
Supplying, installing, testing and commissioning of Sodium Hypochloride dosing system consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing pump having variable flow rate of 0- 15 lph. The motor shall be suitable for operation at 240 V / single phase, 50 Hz. power supply. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. The pump shall be speed & stroke control of reputed make. Motor shall be of energy efficient type meeting the latest BIS/ECBC guidelines complete as per site requirement.

-

-

-

... More
HDPE Tank Capacity : 200 Liter

-

-

-

... More
Dosing Pump Flow Rate : 0-15 LPH

-

-

-

... More
Suitable For Filtered Water Flow Rate: 2.5 LPS

-

-

-

... More
WATER SOFTENER

-

-

-

... More
Supply, installation, testing & commissioning of vertical self supporting FRP Water Softener (suitable for 3 Kg /Sqcm working pressure) compelte with inital charge with T-40 NA resin, multipoint valve with builtin ejector for controlling all operations, regeneration system and HDPE tank, Pressure guage at inlet and outlet and backwash (each with isolation cock), valves, fittings and water hardness testing kit and associated works and suitable PCC foundation. Velocity in frontal piping and valves shall be 1.5 m/sec. Softner shall be suitable for the following duty.

1

102910

102910.29

... More
Raw water hardness 400 Mg/L

-

-

-

... More
Treated water hardness 100 Mg/L

-

-

-

... More
Regeneration Period 10 Hrs.

-

-

-

... More
Capacity : 2.5 LPS

-

-

-

... More
Location : Pump Room

-

-

-

... More
ELECTRICAL INSTALLATION FOR PLUMBING SYSTEM

1

181918

181918.14

... More
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre, IP42,35KA sutaible for 415 Volt, 3 phase, 4 waire, 50Hz AC power supply, shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and /or flats wherever necessary. 3mm thick Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. Entire panel shall have a commom copper bus bar of size 25mm X 5mm at the rear continous earth bus with 2 Nos. earth stud. Lifting hooks shall also be provided.

-

-

-

... More
MCC for Plumbing system

-

-

-

... More
Incoming

-

-

-

... More
2 Nos. 100A, 4P MCCB, 35KA, thermal magnetic based release (Ics = Icu = 100%) with with O/L , S/C & E/F protection as per specification and with following accessories

-

-

-

... More
1 No. Digital Multi function meter and 3 nos. CTs of ratio 100/5A , Class I accuracy and 10 VA burden. digital multifunction meter suitable to measure voltage, Ampere, Frequency, Power Factor with RS-485 Port

-

-

-

... More
1 Set of ON/ OFF/TRIP Indicating LED Lamps with 2 Amp MCB.

-

-

-

... More
1 Set of phase indicating LED lamps with 2 amp back up MCB.

-

-

-

... More
Bus Coupler

-

-

-

... More
1 No. 100A, 4P MCCB, 35KA, thermal magnetic based release (Ics = Icu = 100%) with with O/L , S/C & E/F protection with 1 Set of ON/ OFF Indicating LED Lamps with 2 Amp MCB.

-

-

-

... More
Bus Bar

-

-

-

... More
Four Pole copper bus bars of 125 A capacity with heat shrinkable coloured sleeves i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 35 KA for 1 sec.

-

-

-

... More
Outgoings

-

-

-

... More
2 No. suitable rating MPCB for 1.1 KW DOL starter and outgoing feeder to Filter feed pump (including 1 No. as standby). Each compartment shall contain auto / manual selector swtich and indicating / push button lwith LED lamps.

-

-

-

... More
2 No. suitable rating MPCB for 0.75 KW DOL starter and outgoing feeder to Submersible pump (including 1 No. as standby). Each compartment shall contain auto / manual selector swtich and indicating / push button with LED lamps (spare).

-

-

-

... More
2 No. 32 Amp 4 pole MCCB as outgoing feeder to domestic hydro pneumatic pumps ( 1 working and 1 standby ).(Hydopneumatic water supply)

-

-

-

... More
For submersible Pump MCCB of following capacities:

-

-

-

... More
40 amps 4P MCCB 2 Nos.

-

-

-

... More
Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also be included.

-

-

-

... More
Notes :

-

-

-

... More
a. All MPCBs / MCCBs shall be of 35 KA (min) breaking capacity and suitable for motor duty application.

-

-

-

... More
b. Provision shall be made to ensure system protection from dry running of the pump

-

-

-

... More
c. All incomers and Buscoupler breakers shall be electrical and mechanical interlocked with suitable accessories.

-

-

-

... More
d. 2 Nos. Type-2 SPD 65kA 4P with 1No. Red Indicator Light for SPD with 1Set. SPD Back up fuse, 1P 50A 20kA including all necessary accessories.

-

-

-

... More
MCC - 1 For Plumbing System as described above.

-

-

-

... More
TERRACE PUMP / PRESSURE PUMP

4

25483

101934.73

... More
Supplying, installing testing and commissioning of pressure pump to maintain pressure in down pipe complete in all respects.

-

-

-

... More
Flow Rate :Range 15-20 LPM

-

-

-

... More
Head-10 mtr

-

-

-

-

-

-

... More
Single Phase

-

-

-

... More
Working Pressure : Range 2.0-3.5 kg

-

-

-

... More
Providing, Supllying , installing, commissioning and testing Non Self priming, Multi Stage, Horizontal Centrifugal Pumping Set (monoblock booster pumps) with Electric controller level indicator and Auto cutoff, Switch etc. gate valve and non return valve with other accessories complete in all respect

4

88255

353020.69

... More
Discharge-300 LPM

-

-

-

... More
Head-35 mtr

-

-

-

-

-

-

... More
Design, Supply, Erection & Commissioning of Sewage Treatment Treatment Plant (STP) of Capacity 150 KLD based on with MBBR Technology, Teritary Treatment, includes design & engineering, manufacturing, transporting, installing, testing and commissioning complete including all local and central taxes, freight charges, transit insurance, inspection charges, loading, unloading, conveyance to store/site and stacking the same. Vender to provide details of all design items includes civil works as per approved specification, drawing and instruction of engineering in charge.Including allied Equipments Like Pumps, Screens, Diffused air System, Filters, Disinfection & UV System and all other works contingent there to complete in all Respect.

1

4850000

4850000

... More
FIRE FIGHTING HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
2850 lpm at 70m Head (For Hydrant Pump), Working

1

404830

404830

... More
2850 lpm at 70 m Head (For Hydrant Pump), Stand By

1

404830

404830

... More
1620 lpm at 56 m Head (For water curtain), Stand By

1

284283

284283

... More
Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.

-

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)

-

-

-

... More
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.

-

-

-

... More
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.

-

-

-

... More
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
180 lpm at 88 m Head

2

127148

254296

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
2850 lpm at 70 m Head

1

616966

616966

... More
ELECTRICAL SYSTEM

-

-

-

... More
CONTROL PANELS

1

245730

245730

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :

-

-

-

... More
Incomings

-

-

-

... More
800A, 50kA 4 Pole MCCB, Ics=100% Icu Rating

-

-

-

... More
Digital Voltmeter 0-500V with selector switch

-

-

-

... More
Ammeter (0-800 A) with selector swtich & CTs etc.

-

-

-

... More
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps

-

-

-

... More
Set of Copper Bus Bar 1000Amps

-

-

-

... More
Outgoings

-

-

-

... More
( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)

-

-

-

... More
Main Fire Pump

-

-

-

... More
250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets

-

-

-

... More
Jockey Pump

-

-

-

... More
125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets

-

-

-

... More
DIESEL ENGINE CONTROL

-

-

-

... More
Control for diesel engine comprising -

-

-

-

... More
Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode

-

-

-

... More
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication

-

-

-

... More
Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter

-

-

-

... More
All standard relays and accessories for automatic operation of diesel engine

-

-

-

... More
System Controller

-

-

-

... More
Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

-

-

-

... More
Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank).

-

-

-

... More
Four Way inlet connection

1

9743

9743.88

... More
Two Way inlet connection

1

6573

6573.08

... More
Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all restect

5

3799

18996.34

... More
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

1

8247

8247.5

... More
Size 0.9 m. x 0.9 m.

-

-

-

... More
Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects.

48

6784

325659.44

... More
Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.

60

2047

122846.74

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :

120

4711

565331.28

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :

20

7646

152920

... More
Single headed Stainless steel

-

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :

60

1648

98880

... More
Stainless Steel (Grade 304)

-

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

60

1321

79260

... More
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post officered, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type- 2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.

20

9532

190641.36

... More
Supplying openable steel windows, of standard rolled steel Z sections, joints mitered and Electrically flash-welded, with iron fittings including necessary iron handles, Peg-stay catchers bolts, iron plugs and pressed steel projected hinges and glazing clips, complete (Excluding glazing ) and finished with two coats of ready mixed paint red lead non setting primer

-

-

-

... More
Above one sqm Area

80

113

9102.24

... More
Providing and fixing M.S. angle iron 40x40x6mm chowkhat including iron hold fasts butt hinges fixed in position, finished with red lead non setting primer complete in all respect

-

-

-

... More
1200x600 mm size (all area)

80

102

8175.16

... More
Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S.sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc.

-

-

-

... More
900 mm wide x 600 mm high x 500 mm deep Size (for Yard Hydrant)

20

5541

110832.41

... More
PIPES & VALVES

-

-

-

... More
Providing, laying, fixing and testing M.S. pipe lines as per IS-1239 and specials such as tees, bends, sockets, elbows etc. in trenches in the ground including cutting, threading and testing etc. complete.

-

-

-

... More
100mm internal diameter (thickness 4.50 mm)

5

985

4926.11

... More
150mm internal diametre (thickness 4.85 mm)

610

1830

1116893.2

... More
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.

-

-

-

... More
250 mm dia (wall thickness 6.3 mm)

18

6659

119862

... More
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.

-

-

-

... More
200 mm dia (wall thickness 6.3 mm)

18.9

3336

63055.82

... More
150 mm dia.

2826.6

2202

6224632.96

... More
100 mm dia.

334.95

1517

508132.55

... More
80 mm dia.

858.9

1045

898209.54

... More
65 mm dia.

951.3

860

818362

... More
50mm dia.

1189.65

689

820069.35

... More
40 mm dia.

1380.23

522

721130.01

... More
32 mm dia.

1572.9

394

620465.86

... More
25 mm dia.

6337.8

313

1989774.71

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
250mm dia.

2

20426

40852

... More
Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.

-

-

-

... More
200mm dia.

3

9407

28221.5

... More
150mm dia.

26

5456

141862.37

... More
100mm dia.

2

3431

6862.08

... More
80mm dia.

52

2703

140577.73

... More
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra.

-

-

-

... More
250mm dia.

1

24355

24355.38

... More
200mm dia.

3

16500

49501.39

... More
150 mm dia.

8

8785

70286.74

... More
100 mm dia.

2

5159

10319.56

... More
80 mm dia.

2

4019

8039.85

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :

-

-

-

... More
150mm dia.

1

22762

22762

... More
100mm dia.

1

14641

14641

... More
80mm dia.

1

10996

10996

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
25 mm nominal bore

58

497

28834.7

... More
50 mm nominal bore

1

869

869.2

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

-

-

-

... More
150 mm dia.

4

11144

44576

... More
80 mm dia.

2

4710

9420

... More
Providing & fixing of 25mm dia. gunmetal air release valve with all fittings and forged ball valve on header complete as required and as per enclosed specification.

9

787

7083

... More
Providing and fixing S.S Pressure Gauge complete as required complete in all respect.

-

-

-

... More
Dial diameter 150mm calibration 0-16 Kg

11

711

7821

... More
Supplying and Installation control valve C/W water motor gong complete with alarm Valve, constant trim, water motor bell, 2No. Pressure Gauge. All parts UL listed of Approved reputed Make complete in all respect.

-

-

-

... More
150 mm dia.

1

32476

32476.24

... More
Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required

2

18343

36687.13

... More
Providing and fixing reinforced neoprene rubber vibration eliminators / expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure, complete as per specification.

-

-

-

... More
150mm dia.

8

4982

39856

... More
80mm dia.

4

2847

11388

... More
Supplying & fixing air vessel made out of 450mm. Dia, 8 mm thick MS sheet, 2000mm height with air release valves on top and flanged connection to risers, drain arrangements with 50 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required

8

24950

199605.72

... More
Providing and fixing Vane type Water flow switch in MS Pipe line for a service pressure up to 450PSI , Minimum flow rate for alarm 10GPM (38 LPM ), Minimum surge 18 FPS (5.5 m/s ) including connection with panel complete in all respect

-

-

-

... More
For 50mm to 150 mm pipe line

3

13370

40112.53

... More
Providing and fixing modular construction annunciation panel for flow control switches having 15 zones , 1sets

-

-

-

... More
Fault indication for each zone

-

-

-

... More
Fire/fault hooter.

-

-

-

... More
Alarm panel for fire/fault

-

-

-

... More
Battery for emergency

-

-

-

... More
Battery Charger

-

-

-

... More
Mains supply

1

46471

46471

... More
Providing and fixing heavy duty copper armored cables 1.1 KVA grade including necessary support clamps at ceiling level and connection legs complete in all respects.

-

-

-

... More
Control cable 4 core 1.5 Sq.mm

180

170

30600

... More
AUTOMATIC SPRINKLER SYSTEM

-

-

-

... More
Supplying an Fixing Pendant / Upright type sprinkler with quartzoid bulb, operating temperature 68 / 79 degree centigrade of 15 mm dia orifice sprinler head to approved by UL/SN

3024

268

812597.92

... More
Supplying and Fixing Sidewall Sprinkler rated at 68 / 79degree centigrade, quartzoid bulb type, 15 mm dia orifice sprinler head to approved by UL/SN complete in all respect

30

311

9330.74

... More
Providing and fixing Sprinkler flexible drops stainless steel SS 304 C/W ½ “ NPT on reducer thread, with Max. working pressure of 175 PSI , Test pressure 875 PSI ( BURST ) with branch line ( inlet ) 1” NPT female thread , 01 No reducer , 01 no nipple , 02 no side brackets, 01 no centre brackets etc. complete set , unbraided UL listed complete in all respect.

-

-

-

... More
1500 mm length

300

1243

373182.36

... More
FIRE EXTINGUISHER

-

-

-

... More
PProviding and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.

145

2940

426343.13

... More
Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.

145

7150

1036777.37

... More
Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved make complete in all respect

1

3000

3000.64

... More
Supply, installation, testing and commissioning of Fire man axe and conforming to IS:926 as required as per specifications.

48

848

40750.22

... More
Supply, installation, testing and commissioning of deluge valve (to be use for water curtain ) UL listed with wet pilot basic trim assembly for DVA with test ans alaam, drio and drain valve with water motor gonf compleate as required.

4

115434

461736

... More
HVAC WORK

-

-

-

... More
SUB HEAD 1.0 - HIGH SIDE EQUIPMENTS.

-

-

-

... More
AHRI CERTIFIED WATER COOLED CENTRIFUGAL CHILLER WITH VFD STARTER

3

8998550

26995650

... More
Supply, Installation, Testing and commissioning of Water Cooled Variable Speed Centrifugal type chilled water machines having actual capacity of 550TR with unit mounted/free standing VFD starter with AHRI certified complete with variable speed centrifugal compressor with IP21 Protection, factory insulated chiller (evaporator) water cooled condenser, capacity control, vibration isolation arrangement, flexible pipe joint, factory wired & unit mounted micrpocessor based control console with necessary interlocking & safeties, Liquid line isolation valve etc. as per specifications, gear unit, semi hermitical sealed suitable capacity motor suitable for operation on 3 Phase, 415 V+ 10%V, 50 Hz, electrical supply, VFD starter, all controls and instruments, Control / Power wiring between various components of chiller package and control panel board of the chiller unit provided with suitable size copper conductor cables.Factory Charged charge of refrigerant and oil, Refrigerant R-134a/R-1233zde. (A1 Category Refrigerant)

-

-

-

... More
Advanced microprocessor based control panel along with required hardware & software for integration with a 3rd party BMS (Open protocol), BMS card to be supplied along with chiller( Modbus communication) card, Incomer switchgear with terminations box suitable for terminations of copper cable, earth terminations etc. all mounted on a steel frame, anti vibration pad for cement concrete foundation, bolts,nuts and accessories complete as required & as per specifications with the following characteristics:

-

-

-

... More
Chiller should have Refrigerant leak detection system to detect any refrigerant leakage from the chiller at plant room.

-

-

-

... More
Chiller should be capable of unloading from 100 to 25% capacity at constant condenser water temp. conditions without surging.

-

-

-

... More
Victaulic couplings or Flange connection at the Chiller / Condenser inlet and outlet shall be supplied along with the chiller package.

-

-

-

... More
All provision for descaling of evaporator and condenser on both side to be provided by vendor.

-

-

-

... More
Chilled Water Leaving Temperature : 44 F

-

-

-

... More
Chilled Water Entering Temperature : 56 F

-

-

-

... More
Evaporator Fouling factor : 0.0005 (British Unit)

-

-

-

... More
Chilled Water Circulation Rate : 1320 USGPM

-

-

-

... More
Condenser Water Leaving Temperature : 97.5 F

-

-

-

... More
Condenser Water Entering Temperature : 90 F

-

-

-

... More
Condenser Fouling factor : 0.001 (British Unit)

-

-

-

... More
Condenser Water Circulation Rate : 2200 USGPM

-

-

-

... More
Suitable for Refrigerant : R-134a / R-1233zde (A1 Classified by ASHRAE)

-

-

-

... More
Maximim IKW/TR : 0.60 at site condition

-

-

-

... More
C.O.P of selected chiller at AHRI conditions shall not be less than 6.7

-

-

-

... More
IPLV of selected chiller at AHRI conditions shall not be more than 0.35

-

-

-

... More
NPLV =0.36

-

-

-

... More
The work shall inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading /unloading, port clearance charges etc., shifting to foundation @ Basement and proper installation of machine complete with accessories as required.

-

-

-

... More
Supply, installation, testing and commissioning of Verticle Inline Split Coupled Condenser water centrifugal pumpsets with bronze/SS impeller for Condenser water recirculation complete with Inside type mechanical seal, TEFC Sq. Cage induction motor (IE3) with class "F" insulation, mechanical seal etc. conforming to techinical specification and as per following parameters.(Company Assembled & Factory Fitted). The pump shall be PN 16 rated

-

-

-

... More
Condenser Water Pumps

-

-

-

... More
Capacity of Each Pump LPM 8816

-

-

-

... More
Pump Head (Mt) 20.0

-

-

-

... More
Proposed KW of Motor 37.5

3

712954

2138864.34

... More
Primary chiller Chilled Water Pumps

-

-

-

... More
Supply, installation, testing and commissioning of Verticle Inline Split Coupled chilled water centrifugal pumpsets with bronze/SS impeller for chilled water recirculation complete with Inside type mechanical seal, TEFC Sq. Cage induction motor (IE3) with class "F" insulation, mechanical seal etc. conforming to techinical specification and as per following parameters. The chilled water pumps shall include thermal insulation & cladding. (Company Assembled & Factory Fitted). The pump shall be PN 16 rated

-

-

-

... More
Capacity of each pump (LPM) 4976

-

-

-

... More
Pump Head (Mt) 14.0

-

-

-

... More
Proposed KW of Motor 19.0

3

278726

836179.76

... More
Secondary Chilled Water Pumps

-

-

-

... More
Supply, installation, testing and commissioning of Split Coupled Verticle Inline Chilled water centrifugal pump sets with bronze/SS impeller for chilled water recirculation complete with Inside type mechanical seal TEFC Sq. Cage induction motor (IE3) with class "F" insulation, coupling guard, etc. conforming to technical specification & as per following parameters.The chilled water pumps shall also include the cost of thermal insulation and aluminium cladding.Secondary chilled water pumps shall be suitable for operation on adjustable frequency drives & conforming to the specifications of variable speed pumping system (Company Assembled & Factory Fitted)

-

-

-

... More
Variable Speed Pumping System

-

-

-

... More
Supply, installation, testing and commissioning of Variable Speed Pumping system consisting of Three Numbers suitable adjustable frequency drive in IP55 Enclosure (AFD) integrated & mounted on motor for sensorless / wireless operations) and shall show flow and head for optimized commissioning suitably interfaced with other system components, hand / auto macro designed for pumping application, No. of dedicated microprocessor based pump logic controller, parallel pumping software duly downloaded, interfacing amongst all components and compatibility of I/O signals etc complete with other accessories as required. 01 SET

-

-

-

... More
Capacity of each pump (LPM) 4976

3

1227405

3682215.52

... More
Pump Head (Mt) 38.0

-

-

-

... More
Proposed KW of Motor 55.0

-

-

-

... More
Supply, installation, testing and commissioning of FRP induced draft Cooling Tower (CTI STD 201 Certifiead) of capacity 700 TR (Heat Rejection Capacity - 21,68,800 K Cal per hour.) complete with FRP water basin, PVC fillings, statically and dynamically balanced fan, TEFC motor (IE3) , suction screen, make up & quick fill arrangement, over flow & drain connection, suitable steel ladder etc. and conforming to standard specification. Water Flow Rate - 4536 LPM

-

-

-

... More
Inlet Water Temperature 37.50 °C

-

-

-

... More
Outlet Water Temperature 32.00 °C

3

775362

2326087.5

... More
SUB HEAD 1.0 - HIGH SIDE EQUIPMENTS.

-

-

-

... More
Pressure Maintaining System for Chilled Water System

1

522041

522041.52

... More
Supply,Installation ,testing and commissioning of Pressure maintaining system comprising of :-

-

-

-

... More
pressurised closed expansion tank of M.S construction with interchangeable Synthetic rubber bladder working at ambient pressure with following accessories :auto air vent,Level transducer and drain connection confirming as per specifications and of below capacity. For chilled water application, it will be insulated with 50mm thick insulation to the specifications and cladded with 26G-aluminium cladding.

-

-

-

... More
Capacity of 500 litres PN 16

-

-

-

... More
Pressurised closed expansion tank of M.S construction with interchangeable Synthetic bladder working on nitrogen pressure with following accessories Pressure gage, Safety valve, conforming as per specification and of below capacity. For chilled water application, it will be insulated with 50mm thick insulation to the specifications and cladded with 26G-aluminium cladding.

-

-

-

... More
Capacity of 100 litres PN 16

-

-

-

... More
Pressurisation unit comprising of two multistage high pressure pumps(1 working +1 standby) with control panel with soft starters,valves and other accessories as described in detailed specifications.The pumps shall be able to deliver at least 2 CMH flow at suitable pressure head. Model PMS-260, PN16

-

-

-

... More
Flow 33.33 LPM

-

-

-

... More
Head 60 Meters

-

-

-

... More
SUB HEAD 2.1 - AIR CIRCULATION SYSTEM

-

-

-

... More
Supply,installation,testing & commissioning of factory fabricated Double Skinned Chilled Water Air-handling unit horizontal type fabricated out of extruded aluminium section with 0.8mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8mm plain Galvanised steel sheet inside with blower,blower section & Blower shall be DIDW Forward Curved blade from & blower motor TEFC type suitable for operation on 415volts±10%,50 Hz± 5% AC supply,4 Row cooling coil made of Aluminium finned Copper tube( thickness 0.51mm) with coil section,pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%,polished stainless steel drain pan made out of 22Gsheet duly insulated complete with motor& belt drive package etc.without face & bypass dampers.The AHU panels shallbe insulated with40mm thick &38Kg/m³density PUfoam.The motor&blower assembly shallbe mounted on Aluminium extruded section only.The completeAHUshall conform to standard specification.The face velocity across cooling coil shall be limited to152MPM maxm.The capacity of Air-handlers shall be as follows:

-

-

-

... More
Double Skinned Floor Mounted Air Handling Units with Pre & Fine Filter

-

-

-

... More
Supply, installation, testing and commissioning of factory fabricated Double Skinned Chilled Water Air- handling unit Floor Mounted type fabricated out of extruded aluminium section consisting with 0.8mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8 mm plain alvanised steel sheet inside with blower, blower section and Blower shall be DIDW Forward / Backward Curved blade from and blower motor TEFC type suitable (IE3) for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row cooling coil made of Aluminium finned Copper tube ( thickness 0.50 mm) with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% (MERV 8), & Fine- filter section with non woven synthetic media of 3 micron particle size with an efficiency of 95% (MERV 13), polished stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. without face and bypass dampers. The AHU panels shall be insulated with 40 mm thick & 38 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to standard specification.

-

-

-

... More
The face velocity across cooling coil shall be limited to 152 MPM maxm.The capacity of Air-handlers shall be as follows: Fan Outlet velocity Max 9.6 m/s

-

-

-

... More
(For AHU No. Please Refer Basic Of Design & AC Tender Drawing )

-

-

-

... More
( Horizontal Type )

-

-

-

... More
AHU Static Cooling Motor Coil Area Filter TR

-

-

-

... More
Cap. Pr. Coil Row KW SMT Pre +

-

-

-

... More
CFM mm of wc Deep Filter

-

-

-

... More
16000 55mm 6 Row 15.0 3.16 P+F 38.44

16

503085

8049364.4

... More
Double Skinned Ceiling Suspended Air Handeling Units

-

-

-

... More
Supply, installation, testing and commissioning of factory fabricated Double Skinned Chilled Water Air- handling unit ceiling Suspended type fabricated out of extruded aluminium section consisting with 0.8mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8 mm plain alvanised steel sheet inside with blower, blower section and Blower shall be DIDW Forward / Backward Curved blade from and blower motor TEFC type suitable (IE3) for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row cooling coil made of Aluminium finned Copper tube ( thickness 0.50 mm) with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% (MERV 8), polished stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. without face and bypass dampers. The AHU panels shall be insulated with 25 mm thick & 38 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to standard specification.

-

-

-

... More
SUB HEAD 2.1 - AIR CIRCULATION SYSTEM

-

-

-

... More
The face velocity across cooling coil shall be limited to 152 MPM maxm.The capacity of Air-handlers shall be as follows: Fan Outlet velocity Max 9.6 m/s

-

-

-

... More
(For AHU No. Please Refer Basic Of Design & AC Tender Drawing )

-

-

-

... More
( Horizontal Type )

-

-

-

... More
AHU Static Cooling Motor Coil Area Filter TR

-

-

-

... More
Cap. Pr. Coil Row KW SMT Pre +

-

-

-

... More
CFM mm of wc Deep Filter

-

-

-

... More
4500 50mm 6 Row 3.7 0.84 Pre 8.74

3

168909

506727.98

... More
6000 50mm 6 Row 3.7 1.12 Pre 11.7

4

194886

779546.09

... More
6500 50mm 6 Row 3.7 1.21 Pre 11.7

5

209405

1047025.44

... More
7500 50mm 6 Row 3.7 1.39 Pre 13.4

4

227141

908564.46

... More
8000 50mm 6 Row 3.7 1.49 Pre 18.03

2

245012

490025.26

... More
Supply, installation, testing and commissioning of GI powder coated fan coil units complete with fan, 3 speed motor, 4 row deep cooling coil, aluminium filters with filter box, double sandwitched insulated tray, ball valve with strainer, balancing valve, copper connection & , rotary switch, supporting arrangement, electrical wiring etc. The fan shall be selected for 12 mm static pressure & automatic control for Fan Coil Units consisting of two / three way motorised valves with snape acting motor & thermostat. The complete fan coil unit shall be in line with the standard specification. The capacity of fan coil units shall be as follows:

-

-

-

... More
1.0 TR (400 CFM )

1

15741

15741.23

... More
1.5 TR (600 CFM )

41

17490

717104.34

... More
2.0 TR (800 CFM )

15

19238

288579.75

... More
2.5 TR (1000 CFM )

12

22736

272842.6

... More
3.0 TR (1200 CFM )

78

26817

2091794.91

... More
Supply, installation, testing and commissioning of "Pre assembled complete insulated FCU/AHU LINK consists of:- 3 nos. full port isolating valves in supply, return & bypass, Fixed Orifice Plate Measuring Station, Strainer with stainless Steel Mesh, Drain Cock,Two Pressure / Temperature measuring knobs, Flow regulating valve (Balancing Valve), 2 way control Valve with on/off actuator, Flexible Connector stainless Steel 300mm (2 pieces), Thermal insulating kit made of high Density Black EPP. Pressure rating (PN-20)" (All component should be of one manufacturer. ) of Approved Reputed Make

146

10202

1489565

... More
Up to 4.0 TR ( 20 mm dia.)

-

-

-

... More
SUB HEAD 2.1 - AIR CIRCULATION SYSTEM

-

-

-

... More
High Rangeability 2 way Control valve

-

-

-

... More
Supply, installation, testing and commissioning of complete set of High rangeability control valve or Pressure independant control valve, kit comprising of Two Way Control Valve of Brass construction rotary / ball type for DN15 and DN32 of PN25 rating with screwed connections. DN 40-DN150 shall be C.I body of PN16 ratings, motorised modulating actuators with linear stroke of minimum 15 mm, LCD display digital controller(BMS compatible),three nos NTC sensors with complete wiring with in AHU room,one thermowell,one power supply unit of 230Vac/24Vac.Control box for mounting Digital controller and power supply unit and 10 Amps Double pole MCB should be also provided.The valve size shall be suitable for pipe size/coil TR capacity. (of Approved Reputed Make )

-

-

-

... More
32 mm dia

3

11687

35063.95

... More
40 mm dia

15

29715

445731.99

... More
65 mm dia

16

39354

629676.61

... More
Smart comprehensive Air Purification Solution

-

-

-

... More
The Active Air Purification system should consist of Supply, Installation, Testing and commissioning of Bipolar Ionisation System. The Bipolar Ionisation System must be a combination of Tube Based Model and Needle Point Model (Needle Point should have Nitinol (nickel titanium) Needles) and Carbon Fibre Brush Model, System should produce positive and negative ions for creating a Bio Climate rich in ions and hence neutralising harmful pollutants including pathogens, Volatile Organic Compounds and Particulate Matter. The Carbon Brush self-balancing ionizer should be installed at the fan inlet of fan coil units, VRF cassettes, ductless splits , AHU and Ductable HVAC System. These ionizers should be self-contained in a potted ABS box with a moulded flange and mounting holes and is protected with an inline 500mAglass cartridge fuse. The Needle Point Ionizer should be automatic cleaning needlepoint ionizer producing positive and negative ions that neutralize harmful pollutants and odours in the occupied space. The Needle Point compact unit Should automatically remove dust and dirt build-up on the emitters eliminating the need for any maintenance. The Unit can be easily mounted at the fan inlet of any air handling system, including RTU's, ptacs, mini-splits, fan coil units and VRF systems. The Unit should accept 12-24 VAC/DC. The Tube Based Model should be a single-tube or double tube or 5 tube unit that can be installed in ductwork utilizing the pre-drilled flange and factory applied gasket. The installer makes a duct cut out and secures the unit with self-tapping sheet metal screws. The unit can also be installed inside an AHU, Treated Fresh Air unit, Heat Recovery Ventilation Unit, utilizing a contractor supplied mounting bracket. Power to the ionization unit should be interlocked with system fan operation. The power input fitting provides easy disconnection of the power supply for servicing the unit. A five position ion level control knob varies the ion output between 50% and 100%. The Life of Tube should be minimum 17600 working hours.

-

-

-

... More
Product should have UL 867 and UL 2998 certification (for zero ozone emission). The OEM shall have Efficacy test report on COVID from any Internationally/Nationally recognised Laboratory

-

-

-

... More
SUB HEAD 2.1 - AIR CIRCULATION SYSTEM

-

-

-

... More
The System should be capable of providing periodic Preventive maintenance for automated after sales support service in form of notification/alerts and user interaction through dashboard application.

-

-

-

... More
Supplier must have experience of more than 3 years of executing projects with the same technology products. and have done at least 3 multi-location projects (Private Or Government) Pan India and Minimum Value of each project must be at Least 50 Lac.

-

-

-

... More
Following Certifications are mandatory to produce 

-

-

-

... More
The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must be UL 2043 and UL 1995 certified.

-

-

-

... More
The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must have UL-2998 Certification for Safety against Zero Ozone Emission as per recommendation by ASHRAE.

-

-

-

... More
The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer and Tube Based Model Should be tested on UL or Intertek/ETL to prove conformance to UL 867 for electronic devices.

-

-

-

... More
Other Product Certifications required are ISO16000 , CSA C22.2# 187, and CARB.

-

-

-

... More
Manufacturers shall provide Test report from Internationally/Nationally recognized Lab for proven efficacy on below pathogens with minimum kill rates for the following pathogens given the allotted time and in a space condition: a) SARS-CoV-2 (COVID-19) Human Strain b) MS2 Bacteriophage (Surrogates COVID-19) c) Omicron Variant of SARS-CoV-2 d) H1N1 e) Total Bacterial Count Reduction rate of more than 90% from NABL Accredited Lab f) Yeas & Mold/Total fungal count Reduction rate of more than 90% from NABL Accredited Lab

-

-

-

... More
Make :- Approved Reputed make

-

-

-

... More
Floor / Ceiling Suspended Mounted AHU ( 3,88,000 CFM Apx.)

1

4444598

4444598.4

... More
FCU - Total 146 No

1

1846144

1846144.08

... More
Supply installation, testing and commissioning of Variable Frequency drive of AHU IP-55 with digital display. with Remort control switch option with by pass syetem of AHU panel with Variable frequency drive

-

-

-

... More
3.7 KW

18

51442

925968.78

16

85043

1360703.34

... More
SUB HEAD 2.2 - PIPING & INSULATION WORK

-

-

-

... More
INSULATED CHILLED WATER PIPING ( Expanded Polystrene Insulation)

-

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.

-

-

-

... More
Note : The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. The pipes shall be joined using Grooved Couplings & Fittings as per BOQ and Specification

-

-

-

... More
25 mm dia.( 50 mm thick EPS with Al Cladding )

450

1292

581400

... More
32 mm dia.( 50 mm thick EPS with Al Cladding )

720

1430

1029600

... More
40 mm dia.( 50 mm thick EPS with Al Cladding )

600

1631

978600

... More
50 mm dia.( 50 mm thick EPS with Al Cladding )

800

1917

1533600

... More
65 mm dia.( 50 mm thick EPS with Al Cladding )

800

2300

1840000

... More
80 mm dia.( 50 mm thick EPS with Al Cladding )

400

2714

1085600

... More
100 mm dia.( 50 mm thick EPS with Al Cladding )

120

3468

416160

... More
125 mm dia.( 50 mm thick EPS with Al Cladding )

50

4057

202850

... More
150 mm dia.( 50 mm thick EPS with Al Cladding )

520

4834

2513680

... More
200 mm dia.( 75 mm thick EPS with Al Cladding )

120

7226

867120

... More
250 mm dia.( 75 mm thick EPS with Al Cladding )

210

6616

1389360

... More
300 mm dia.( 75 mm thick EPS with Al Cladding )

50

10245

512250

... More
350 mm dia.( 75 mm thick EPS with Al Cladding )

120

11558

1386960

... More
SUB HEAD 2.2 - PIPING & INSULATION WORK

-

-

-

... More
INSULATED VALVES

-

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated ( Class O Nitrial rubber ) to the same specifications as the connected piping and adequately upported as per specifications.

-

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified

-

-

-

... More
25 mm dia. (Globe Valve)

20

2472

49440

... More
40 mm dia. (Globe Valve)

10

3501

35010

... More
50 mm dia.

30

4129

123870

... More
80 mm dia.

36

4846

174456

... More
100 mm dia.

32

6640

212480

... More
250 mm dia.

18

15661

281898

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.

-

-

-

... More
40 mm dia.

5

7614

38070

... More
50 mm dia.

15

10739

161085

... More
80 mm dia.

18

13771

247878

... More
250 mm dia.

3

34461

103383

... More
NON - RETURN VALVE with duel plate of C I body SS plates anized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.

-

-

-

... More
250 mm dia.

6

14492

86952

... More
SUB HEAD 2.2 - PIPING & INSULATION WORK

-

-

-

... More
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.

-

-

-

... More
40 mm dia.

3

4399

13197

... More
50 mm dia.

15

5892

88380

... More
80 mm dia.

16

9882

158112

... More
150 mm dia.

16

28033

448528

... More
250 mm dia.

6

49724

298344

... More
Providing and fixing in position the industrial type pressure gauge complete as required

62

1196

74152

... More
Providing & fixing in position the mercury in glass industrial type thermometer complete as required

44

1043

45892

... More
CONDENSER WATER PIPE

-

-

-

... More
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.

-

-

-

... More
Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.

-

-

-

... More
40 mm dia.

20

2200

44000

... More
50 mm dia.

20

2450

49000

... More
80 mm dia.

70

2691

188370

... More
150mm dia.

90

3699

332910

... More
200 mm dia.

50

5526

276300

... More
300 mm dia.

50

7888

394400

... More
450 mm dia.

120

9860

1183200

... More
VALVES WITHOUT INSULATION

-

-

-

... More
Supplying, fixing, testing and commissioning of following size valves, gauges and strainers for condenser water circulation as per specifications.

-

-

-

... More
SUB HEAD 2.2 - PIPING & INSULATION WORK

-

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O-ring & PN 16 pressure rating as specified.

-

-

-

... More
65 mm dia.

4

3821

15284

... More
100 mm dia.

2

5412

10824

... More
300 mm dia.

18

7033

126594

... More
450 mm dia.

4

14156

56624

... More
NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as pecified.

-

-

-

... More
300 mm dia.

3

12965

38895

... More
Supply, installation, testing and commissioning of Pot - Strainer (sspl) of the following sizes conforming to standard specification.

-

-

-

... More
450 mm dia

2

12965

25930

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for Condenser water circulation as specified.

-

-

-

... More
300 mm dia.

3

69603

208809

... More
Supply, installation, testing and commissioning of common pressure guage across the chilled water supply / return to AHU only as per specification.

16

704

11268.22

... More
Supply and fixing of UPVC drain water piping complete with fittings, support as per specification and insulated with 9 mm thick insulated with Class O Nitrile Rubber insulation.

-

-

-

... More
25 mm dia pipe

1100

45

49867.49

... More
32 mm dia pipe

200

72

14514.37

... More
50 mm dia pipe

300

180

54149.04

... More
Supply, installation, testing and commissioning of auto air vent valve of following sizes:-

-

-

-

... More
12 mm dia auto air vent valve

100

844

84418.4

... More
SUB HEAD 2.3- AIR DISTRIBUTION & INSULATION SYSTEM

-

-

-

... More
DUCTING, GRILLS,DIFFUSER AND INSULATION

-

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
0.63 MM (24 gauge) Galvanized Sheet Steel

2100

1080

2268000

... More
0.8 MM (22 gauge) Galvanized Sheet Steel

1100

1263

1389300

... More
1.0 MM (20 gauge) Galvanized Sheet Steel

5500

1381

7595500

... More
1.25 MM (18 gauge) Galvanized Sheet Steel

100

1836

183600

... More
Supply,installation and testing of powder coated aluminium extruded grills/diffusers as per specifications given in tender and of following sizes:

-

-

-

... More
Single Louvered supply / Return Air registers (Grill)

65

4197

272844

... More
Supply / return suare ceiling air terminals (diffusers)

140

8348

1168798.4

... More
Fresh / Exhaust air louvers with bird screen & damper

8

10913

87310.08

... More
Flexible connection for AHU/FCU madeup of f/r fabric compelte with flange

50

5223

261184

... More
Countinous grill 150 mm dia

550

629

346302

... More
Supply,installation and testing of multiblade type GI Duct Damper for duct/collars to be provided with suitable links and quadrants for control of volume of air

65

8861

576004

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.

-

-

-

... More
Damper

30

10659

319770

... More
Actuator

45

9948

447660

... More
SUB HEAD 2.3- AIR DISTRIBUTION & INSULATION SYSTEM

-

-

-

... More
Supply and installation of acoustic one side open cell oxide acetate aco isolate foam having density of 30 to 33 Kg/ M³ ,having temp range of -40°C to +115°C and fire rating Class 1 as per BS 476 Part 7 and Class O as per BS 476 Part 6 as per the approved specifications. Material shall be HCFC/CFC free as per US EPA 5021 A (2014 )

-

-

-

... More
15 mm thick

1400

489

685608

... More
Supply and installation of Crosslinked Closed cell Polyethylene FR XPE Thermal insulation on ducts having density 0f 30± 3 Kg/ M³ ,having K value 0.0314 W/m ° K at 23°C Deg temp and temp range of -40°C to +115°C and fire rating Class O as per BS 476 Part 6 from Exova Warringtonfire-UK and CBRI,Roorkee as per the approved specifications. Material shall be HCFC/CFC free as per US EPA 5021 A (2014 )

-

-

-

... More
19 mm thick Closed Cell Cross Linked Polythylene( XLPE) Foam with Factory Laminated Al PE Foil for Supply Air Duct

8800

298

2626764.8

... More
SUB HEAD 2.4 - ELECTRICAL WORK

-

-

-

... More
CUBICAL PANEL BOARD For

1

1953763

1953763.59

... More
i) 550 TR Actual Water-Cooled centrifugal hilling Machine ( 2W+1S)

-

-

-

... More
ii) 40.0 KW CDW Pumps (2W+1S)

-

-

-

... More
iii) 15 KW (700 TR) Cooling Tower (2W+1S)

-

-

-

... More
iv) 19.5 KW P.CHW Pumps (2W+1S)

-

-

-

... More
v) 55.0 KW S.CHW Pumps (2W+1S)

-

-

-

... More
Supply, installation, testing and commissioning of non draw out Cubical type sectinalised & Compartmentalised floor standing powder coated switch board of 31 MVA fault capacity at 415 V complete with 4 strip, 1500 A capacity Aluminium Bus - Bar Electrolytic grade,cable alley & supplying & fixing of following switchgears as per specifications including connections & interconnections.

-

-

-

... More
i) INCOMER

-

-

-

... More
02 No. - 1250A FP ACB Microprocesser ased adjustable protection relays type with overload,short ckt.,earth fault protection release & under voltage protection, selector switch, 96mm ammeter & 96mm Voltmeter with selector switches, phase indication light with protection fuse,on / off / trip indicating light with Protection Fuse. ACB shall be of 50 KA (Icu = Ics).

-

-

-

... More
ii) Bus Coupler

-

-

-

... More
01 No. - 1250 4 Pole ACB Manual Draw out manually operated drawout ype Bus Coupler. MCCB shall be of 50 KA

-

-

-

... More
iii) Incomers and bus coupler shall be mechanically electrically interlocked with one set of castle key interlocking system ( 3 locks and 2 keys )interlocked to avoid paralleling of the two supplies.

-

-

-

... More
OUTGOINGS

-

-

-

... More
For 3 Nos. 550 TR Centrifugal Water Chilling Machine

-

-

-

... More
03 NO. - 800 A FP MCCB Thermal Maganitic release adjustable type with overload,short ckt.,Protection, on/off /trip indicating light with Protection Fuse. MCCB shall be of 50 KA (Icu = Ics).

-

-

-

... More
SUB HEAD 2.4 - ELECTRICAL WORK

-

-

-

... More
For 3 Nos. 40.0 KW Condenser Water Pumps.

-

-

-

... More
03 No. - 100 A TP MCCB with Conforming to BIS star Delta starter, overload relay, start/stop push buttons, ammeter (0-100A) with three CT, on / off / trip indication lights with protection fuse, single phase preventer.

-

-

-

... More
For 3 Nos. (12 x 5.5 KW) - Cooling Towers.

-

-

-

... More
12 No. - 40 A TP MCB with Conforming to BIS star Delta starter, overload relay, start/stop push buttons, ammeter (0-40A) with three CT, on / off / trip indication lights with protection fuse, single phase preventer.

-

-

-

... More
For 3 Nos. 19.5 KW P. Chilled Water Pumps.

-

-

-

... More
03 No. - 63 A TP MCB with Conforming to BIS star Delta starter, overload relay, start/stop push buttons, ammeter (0-40A) with three CT, on / off / trip indication lights with protection fuse, single phase preventer.

-

-

-

... More
For 3 Nos. 55 KW S. Chilled Water Pumps.

-

-

-

... More
03 No. - 200 A TP MCCB with Conforming to BIS star Delta starter, overload relay, start/stop push buttons, ammeter (0-200A) with three CT, on / off / trip indication lights with protection fuse, single phase preventer.

-

-

-

... More
Controls & interlocking accessories as Complet with Connection / interconnection required for above switchgears

-

-

-

... More
SUB - PANELS FOR AIR HANDLING UNITS ( BMS Compatable )

-

-

-

... More
Supply , installation , testing and commissioning of wall mounted switch board as detailed below & conforming to the specification. Including connections & interconnection etc as required.

-

-

-

... More
AHU Sub Panel - Supply Air Blower ( Up to 5.5 KW)

18

54925

988652.33

... More
01 No. - 40 A TP MCB with Conforming to BIS 25A Direct on Line starter, overload relay, start/stop push buttons, ammeter (0-40A) on / off / trip indication lights with protection fuse, single phase preventer with Remort control switch option with by pass syetem of AHU Variable frequency drive .

-

-

-

... More
AHU Sub Panel - Supply Air Blower ( 7.5 KW to 15 KW)

16

8243

131897.92

... More
01 No. - 40 A TP MCB with Conforming to BIS 25A Star Delta starter, overload relay, start/stop push buttons, ammeter (0-40A) on / off / trip indication lights with protection fuse, single phase preventer with Remort control switch option with by pass syetem of AHU Variable frequency drive .

-

-

-

... More
SUB HEAD 2.4 - ELECTRICAL WORK

-

-

-

... More
POWER & CONTROL CABLING

-

-

-

... More
Supply, laying, testing and commissioning of power and control cabling, as per Standard specification including end termination as required.

-

-

-

... More
Power Cabling (FRLS) insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on cable trays).

-

-

-

... More
2 x 3.5C x 300 Sq. mm

250

60176

15044198.4

... More
3C x 35Sq. Mm

150

2887

433192.32

... More
3C x 25 Sq. mm

100

2084

208480.8

... More
3C x 10 Sq. mm

100

916

91600.96

... More
3C x 6 Sq. mm

150

569

85491.12

... More
2 x 3.5C x 240 Sq. mm

150

47841

7176216.96

... More
Earthing Strip / Wires.

-

-

-

... More
Pdg.and fixing 25 x 5 mm G.I. strip along with Cable Tray as required.

150

7253

1087950

... More
Pdg. & fixing 6 SWG GI wire on surface or in recess , along with the exiting cable for loop earthing Including connection etc as required.

800

8618

6894400

... More
Supply & laying of rubber mat of size 900 mm & 12 mm thick

8

3358

26864.64

... More
SITC of 63 A FP MCCB in duly enclour in MS box including complete with connection / interconnection etc. as required for Conforming to Specification for cooling tower

12

4197

50371.2

... More
Supply, installation, testing and commissioning of 200 Dia Prpoellar Fan with all electrical fitting and Cable with Bird Screen louver etc. as per specification.

40

5410

216409.6

... More
SUB HEAD 3.0 - MECHANICAL VENTILATION SYSTEM

-

-

-

... More
Supply installation, testing and commissioning of Inline Fan directly coupled TEFC Sq.cage induction motor (F-class insulation & B-class Temp. rise) suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc.

-

-

-

... More
Toilet Exhaust Inline Ventilation fan

12

6937

83252.4

... More
Air Qty. = 600 CFM

-

-

-

... More
Static Pressure = 8 mm Wg

-

-

-

... More
Fan Speed = not exceeding 2500 rpm

-

-

-

... More
Motor = 0.1 KW

-

-

-

... More
Fan Dia = 300 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
Toilet Exhaust Inline Ventilation fan

24

8243

197846.88

... More
Air Qty. = 800 CFM

-

-

-

... More
Static Pressure = 8 mm Wg

-

-

-

... More
Fan Speed = not exceeding 2500 rpm

-

-

-

... More
Motor = 0.15 KW

-

-

-

... More
Fan Dia = 300 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
Toilet Exhaust Inline Ventilation fan

16

8243

131897.92

... More
Air Qty. = 900 CFM

-

-

-

... More
Static Pressure = 8 mm Wg

-

-

-

... More
Fan Speed = not exceeding 2500 rpm

-

-

-

... More
Motor = 0.15 KW

-

-

-

... More
Fan Dia = 300 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
Toilet Exhaust Inline Ventilation fan

1

22037

22037.4

... More
Air Qty. = 1500 CFM

-

-

-

... More
Static Pressure = 10 mm Wg

-

-

-

... More
Fan Speed = not exceeding 2500 rpm

-

-

-

... More
Motor = 0.15 KW

-

-

-

... More
Fan Dia = 300 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
SUB HEAD 3.0 - MECHANICAL VENTILATION SYSTEM

-

-

-

... More
Supply installation, testing and commissioning of Vane Axial long casing( length of the casing should not be less than diameter of the fan) fan confirming to IS-3588 (revised) complete with tube casing in MS/GI standard construction epoxy painted, impeller with adjustable blade angles, bird screen ,gravity louvers, fire retardent double fold moisture and fire proof with flame retardent fabric confirming to IS-206 (revised) fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (H-class insulation & B-class Temp. rise) suitable for 415V±10%, 50 Hz. 3 phase ( IE3) electric supply complete with required hardware etc.Fan shall be AMCA air and sound certified.

-

-

-

... More
Air Ventilation fan ( In Case of fire)

4

111819

447277.6

... More
Air Qty. = 24000 CFM

-

-

-

... More
Static Pressure = 25 mm Wg

-

-

-

... More
Fan Speed = not exceeding 1450 rpm

-

-

-

... More
Motor = 15.0 KW

-

-

-

... More
Fan Dia = 1000 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
Air Ventilation fan (Normal)

4

111819

447277.6

... More
Air Qty. = 24000 CFM

-

-

-

... More
Static Pressure = 25 mm Wg

-

-

-

... More
Fan Speed = not exceeding 1450 rpm

-

-

-

... More
Motor = 15.0 KW

-

-

-

... More
Fan Dia = 1000 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
Air Ventilation fan ( In Case of fire)

8

289783

2318269.18

... More
Air Qty. = 47000 CFM

-

-

-

... More
Static Pressure = 25 mm Wg

-

-

-

... More
Fan Speed = not exceeding 1450 rpm

-

-

-

... More
Motor = 25.0 KW

-

-

-

... More
Fan Dia = 1000 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
Pressurization of Lift Lobby

12

52783

633403.85

... More
Air Qty. = 8000 CFM

-

-

-

... More
Static Pressure = 25 mm Wg

-

-

-

... More
Fan Speed = not exceeding 1450 rpm

-

-

-

... More
Motor = 3.7 KW

-

-

-

... More
Fan Dia = 710 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
SUB HEAD 3.0 - MECHANICAL VENTILATION SYSTEM

-

-

-

... More
Pressurization of Staircase

4

52783

211134.62

... More
Air Qty. = 7500 CFM

-

-

-

... More
Static Pressure = 25 mm Wg

-

-

-

... More
Fan Speed = not exceeding 1450 rpm

-

-

-

... More
Motor = 3.7 KW

-

-

-

... More
Fan Dia = 710 mm (Approx.)

-

-

-

... More
Noise level = not exceed 90 db at 1 meter distance

-

-

-

... More
Sub Panel- Supply /Exhaust Air Blower up to 7.5 KW)

16

19817

317077.38

... More
( BMS Compatable)

-

-

-

... More
01 No. - 40 A TP MCB with Conforming to BIS 25 A DOL starter, overload relay, start/stop push buttons, ammeter (0-63A) on / off / trip indication lights with protection fuse, single phase preventer.

-

-

-

... More
Controls & interlocking accessories as Complet with Connection / interconnection required for above switchgears LOT

-

-

-

... More
Sub Panel- Supply /Exhaust Air Blower up to 15 KW)

16

31482

503719.46

... More
( BMS Compatable)

-

-

-

... More
01 No. - 40 A TP MCB with Conforming to BIS 25 A DOL starter, overload relay, start/stop push buttons, ammeter (0-63A) on / off / trip indication lights with protection fuse, single phase preventer.

-

-

-

... More
Controls & interlocking accessories as Complet with Connection / interconnection required for above switchgears LOT

-

-

-

... More
Electrical Works

-

-

-

... More
SUBSTATION WORKS

-

-

-

... More
XLPE INSULATED HT CABLES:

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:-

-

-

-

... More
HT Cable Overall size 240sq.mm (3Core)

100

2041

204168

... More
XLPE INSULATED HT ARMOURED CABLES (LOOSE):

-

-

-

... More
Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid loose in the existing trench or pipe:-

-

-

-

... More
HT Cable Overall size 240sq.mm (3Core)

20

1605

32110.6

... More
HT CABLE TERMINATION

-

-

-

... More
S/E of Heat shrinkable cable end termination / Straight through joint kit for 11 KV /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge

-

-

-

... More
Heat Shrinkable End Termination for cable size 240-400 sq. mm, 3Core (Indoor Type)

5

4635

23178.05

... More
Heat Shrinkable End Termination for cable size 240-400 sq. mm, 3Core (Outdoor Type)

1

5473

5473.35

... More
11 KV HT BREAKER PANEL

-

-

-

... More
Design, Manufacture, Supply, unloading and placing it on foundation, Installation, Testing and Commissioning of Indoor Duty HT VCB Panel as per following; Note 1: For detail refer Technical Specifications enclosed. Note 2: Vendor to Study Site & Confirm Horizontal & Vertical Transportation of Each set to location without Dismantling any component after Factory Testing is Conducted. Note 3: Vendor to make all constructional damages good which occurred to any part of the building during transportation.

-

-

-

... More
H.T.PANEL (In Proposed Substation)

1

1765664

1765664

... More
Supply, Installation, Testing and Commissioning of 11 KV, 350 MVA (18.3 KA), 3 sec, 630A, HT, 3 (Three) Panel VCB Switchboard (One Incomer + Two outgoings), cubicle type, made out of 14 SWG sheet steel, totally enclosed, IP 42 free standing, floor mounting, dust and vermin proof ,indoor, compartmentalised, powder coated painting, suitable for operation on 11 KV, 3ph, 50 Hz system with 630 Amps. copper busbars, VCB mounted on horizontally with drawable truck including 24 volts DC (from battery pack for breaker ON/OFF/TRIP indicating lights and Breaker closing & Trip Coils and Relays etc. The panel shall be complete with cable termination arrangement for incoming & outgoing XLPE, 11 KV cable as specified.

-

-

-

... More
Each Incomer shall comparises;

-

-

-

... More
11 KV, 350 MVA (18.3 KA), 3 sec ,630A VCB, Electrically operated, draw out type, with PT, 11KV/110V, indication lamps, digital meters with communication port, Digital protection relays with communication port, required number of CTs for metering and protection - 1 no.

-

-

-

... More
Suitable class cast resin draw out type potential transformer, 11kV/110V, 100VA, with control fuses, distribution connectors, control wiring etc. as bus PT as required and as per specifications.

-

-

-

... More
Each Outgoing shall comparises;

-

-

-

... More
11 KV, 350 MVA (18.3 KA), 3 sec, 630A VCB, Electrically operated, draw out type, indication lamps, digital meters with communication port, numerical protection relays with communication port,annunciation window with bucholtz alarm, trip, winding temperature alarm, trip, oil temperature alarm trip, over current trip, earth fault trip, REF trip, required number of suitable range CTs for metering and protection - 2 nos.

-

-

-

... More
All metering and protection devices, interconnections, necessary control wiring, cabling and all other accessories shall be provided as per Technical Specifications, Technical particulars & Single line Diagram.

-

-

-

... More
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5 sqmm subjected to providing minimum size strip suitable for 4/6 sqmm.

-

-

-

... More
POWER TRANSFORMER (At Proposed S/STN)

-

-

-

... More
Design, Manufacture, Supply, unloading and placing it on foundation, Installation, Testing and Commissioning of Indoor Duty Power Transformer as per following; Note 1: For detail refer Technical Specifications enclosed. Note 2: Vendor to Study Site & Confirm Horizontal & Vertical Transportation of Each set to location without Dismantling any component after Factory Testing is Conducted. Note 3: Vendor to make all constructional damages good which occurred to any part of the building during transportation. Note 4: Manufacturer's must have NABL approved and certified in house testing labotatory. Note 5: Inspection Cost at manufacturing unit shall be in scope of bidder. Note 6: Transformer shall be designed for 110% continuous overfluxing withstand capabilites as per latest ammended IS 6600.

-

-

-

... More
Oil Type Transformer

2

5786394

11572788

... More
Supply, unloading, shifting, placement on foundation, Installation, Testing and Commissioning of outdoor type 1600 KVA, 11/0.415 KV, 3 Phase, 50Hz, Dyn11vector group, copper wound, mineral oil immersed, Delta/Star ONAN power Transformer with ON LOAD Tap Changer on HV side in steps of 2.35% for + 13.64 to - 22.73 the transformer shall have SCADA compatible, with RTCC panel having cable end box on HV side suitable for 1x 3C x 300 mm² HT XLPE (E) cable of 11 KV grade and 3200 amps sandwitch type LT busduct on LV side complete with all required accessories. The power transformer shall have winding temp indicator with trip alarm switches also shall have minimum 2 RTD's per phase winding. Impedence of transformer shall be 6.25%. The transformer shall be Energy Efficiency "LEVEL-2" as per IS-1180 (latest ammendment-2022) and the losses shall not exceed 3970 at 50% and 11300 at 100% load. The vendor shall supply, laying, terminating suitable size control cables between transformer and HT panel and complete test prior to handing over shall be conducted at site.

-

-

-

... More
All instruments Connecting control wiring to be done up to Marshalling box.

-

-

-

... More
Installation & testing shall be done by the electrical contractor in the presence of engineer in charge .

-

-

-

... More
The supplier shall certify that the Transformer has installed as per norms.

-

-

-

... More
RISING MAINS & BUS TRUNKING/DUCTS

-

-

-

... More
SITC 1600A (Offering 2000A) Sandwich type (Cu + Tin Plated Throughout length), Aluminium Feeder busway (3L+N+PE), with Multi Layer PET Class-F Insulation, 100% N, 80kA for 1 sec, Integral Earth in GI as Standard with IP-65, 12kV Impulse Withstand, C-Ribbed Housing in 1.5mm Thick, Paint:-RAL-7035, Temp rise: 55 deg. over ambient of 40 deg. & operating voltage = 1000V Straight Length

40

62502

2500080

... More
SITC 3200A (Offering 4000A) Sandwich type (Cu + Tin Plated Throughout length), Aluminium Feeder busway (3L+N+PE), with Multi Layer PET Class-F Insulation, 100% N, 160kA for 1 sec, Integral Earth in GI as Standard with IP-55, 12kV Impulse Withstand, C-Ribbed Housing in 1.5mm Thick, Paint:-RAL-7035, Temp rise: 55 deg. over ambient of 40 deg. & operating voltage = 1000V STRAIGHT LENGTH

60

122064

7323840

... More
DIESEL GENERATING SETS AND ALLIED WORKS

-

-

-

... More
Diesel Generators 500KVA

-

-

-

... More
Supply, Erection, testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 500 KVA/400KW it should be air cooled/water cooled naturally aspirate d/turbo charged/ turbo charged after cool (As per manufacturer standard). DIESEL ENGINE: 6 cylinders, inline, 4 stroke cycle, Water cooled developing 594 BHP at 1500 RPM .The engine shall be provided with electrical starting arrangement and shall give the electrical output of 500KVA/400KW at 0.8 power factor, 415 Volts at the alternator terminal. Other accessories of the engine would be as under: COOLING SYSTEM Radiator cooled,Engine mounted Water pump,Thermostats,Coolant,Self-contained piping, EXHAUST SYSTEM ,Exhaust manifold ,Flexible piping,Silencer - Specially designed well attenuated silencer to meet emission norms is provided FUEL SYSTEM High pressure common rail fuel system Spin on type Fuel filters Self contained piping GOVERNING SYSTEM PSO 602 Sync Capable controller LUBRICATING SYSTEM Lub Oil pump Spin on type lub oil filter Self-contained piping STARTING SYSTEM Starter, 24V, DC Battery charging Alternator With in-built Regulator AIR INTAKE SYSTEM Dry type replaceable paper element airfilter Air intake manifold with necessary connections Turbo charger OTHER SYSTEM Flywheel Flywheel housingEngine After Treatment System Along with Diesel Exhaust Fluid (DEF) Tank for Precise emission control meeting CPCB4+ Norms.

-

-

-

... More
Genset controller Microprocessor based generator set monitoring, metering and control system with LCD display designed to meet the exacting demands of engine driven generator sets ■ AMF Functionality ■ Electronic Governing ■ CAN (J1939) Compatible ■ Sync Compatible (Capable to accept external speed signal from 3rd party sync controller) ■ Intuitive operator interface which includes LED backlit 128X64 pixel graphic display with tactile feel soft- switches & generator set status LED lamps.■ Remote start-stop ■ Engine Metering: Oil pressure, Engine temperature, battery voltage, Engine running hours ■ AC Alternator Metering: L-L Voltage and L-N Voltage, ■ Current (phase and total), kVA (phase and total), Frequency, kWH, kW and kVA (phase and total), PF, Utility Voltage and Freq. ■ Engine Protection: Low lube oil pressure, High/ Low coolant temperature, Battery Over/ Under/ Weak Volts, Fail to Crank/ Start, Sensor failure, Cranking lockout. ■ AC Alternator Protection: Over/ Under Voltage, Over/ Under Frequency, Loss of AC Sensing, Over speed, Over Current. ■ Data Logging: Engine Hours, Control Hours and upto 5 recent fault codes ■ Configurable glow plug control ■ 12/24 Volt DC operation ■ Sleepmode ■ Mod bus interface ( RS485 RTU) ■ In Power compatible (PC based service tool) ■ Certifications - meets the requirement of relevant ISO, EN, Mil Std. and CE standards Maint enance due alarm based on Engine Run Time and due date ■ Exerciser scheduler Fuel Level Indication

-

-

-

... More
ALTERNATOR: Output : 500KVA, Power factor : 0.8, Rated Generating Voltage : 415 Volts, Voltage regulation : +/- 1% all load between no load to full load & factor 0.8 to unity Frequency : 50 Hz Speed : 1500 RPM Class of insulation : H Winding connection : Star connection (all six leads will be brought out of stator frame) Overload capacity : 10% for one hour in any 12 hours of operation without exceeding temperature rise limits specified in IS60034 when corrected to ambient temperature at site. Bearings : Long life single bearing Enclosures : Drip proof & screen protected IP-23 The alternator shall be of self-excited, self regulated, self ventilated in brushless design, provided with suitable automatic voltage regulator and shall conform to IS60034 and shall give rated output at NTP conditions. ESSENTIAL ACCESSORIES: One set of essential accessories shall be supplied with each D.G. Set. This set of accessories shall comprise of the following: BASE RAIL: Base rail with integral fuel tank is provided FUEL TANK: One no. sub base fuel tank of 745 LITRES capacity for each DG set is provided in the base rail.Tank is typically suited for 8 hrs. of operation (@75% Load) BATTERIES: For electrical control circuit of 24 volt DC, 2 Nos. batteries of 12 volts each with battery leads for electrical starting of each DG Set. Battery Charger EMI/EMC compliant static battery charger (82.5 KVA & Above) Battery isolator Switch Telematics For DG Monitoring- Std for 82.5 KVA & above. External Fuel Filling Arrangement ** DG Set Confirming to ISO8528 .

-

-

-

... More
Salient Features Silent DG Set Compact, Sleek, Manual/ Automatic.,Sound proof, Weather proof enclosure ,Conform to statutory Govt. noise level norms,The Enclosure is of modular construction with the provision to assemble and dismantle easily,The Enclosure is fabricated in 6SWG-CRCA-sheet.The sheet metal components are Eleven tank pretreated and is Polyester based powder coated (inside as well as outside) for long life.All Nuts-bolts, hardware are of Stainless Steel.Battery is provided in a tray inside the Enclosure.Doors are gasketed with high quality EPDN gaskets to avoid leakage of sound.Sound proofing of enclosure is done with high foam,Specially designed attenuated exhaust silencer to meet CPCB-4 noise norms.Specially designed sound ttenuators are provided to control sound at air entry & exit points inside the Enclosure.To make the system vibration free, engine and alternator are mounted on specially designed anti-vibration pads mounted on Base frame.The enclosure is designed and layout of the equipment is such that there is easy access to serviceable parts.Adequate ventilation is provided to meet air requirement for combustion & heat removal.There is an arrangement for illumination inside the Enclosure.The silent DG set has the following safeties:High water temperature.Low lub oil pressure.High enclosure temperature.Emergency stop push button outside the Enclosure.Control panel is mounted inside Enclosure itself.DG Set is warranted for 2 yrs. Or 5000 Hrs. Operation. Noise level is 75 dB(A) at distance of 1 mtr. in open free field environment as per ISO8528 part 10.

-

-

-

... More
SOUND ATTENUATED SYSTEM THICKNESS OF SHEET - 16-G High class sheet metal fabricated enclosure for reducing the noise level of DG set & also acts as a weather proof housing. Genset will be a integral part of acoustic enclosure and whole construction will be on multi-fold sheet channels & ISMC sections. Enclosure construction is fully bolted keeping in view the major service requirements all doors are provided with specially designed hinges and lockable handles, Battery, Fuel tank ishoused inside the enclosure. ACOUSTIC MATERIALS Foam/Rokwool of suitable density & thickness to meet noise norms. VENTILATION Acoustic enclosure is designed in such a way that there are no hot pockets around engine and it is provided with suitable designed engine radiator which does not allow the temperature to rise more than 70C above ambient temperature. To achieve optimal output and minimum sound level from the DG set, suitable openings are provide for increasing the inflow of air required for combustion & forced ventilation. Air intake system as per the recommendations and engine requirement are provided. The sound control system designed to suppress the sound level to 75 db maximum at 1 mtr. distance in open free field environment as per ISO 8528 part 10. SILENCER Specially designed low noise silencer installed inside the enclosure. Silencer & engine exhaust outlet, Connected with flexible SS below. VIBRATION ISOLATION To avoid transfer of vibration from genset to enclosure & surrounding specially designed vibration isolators are used.

-

-

-

... More
CONTROL PANEL FOR DG SET The Generator control shall be indoor type, floor mounted, dust and vermin proof in sheet steel construction. The panel shall have doors at the front and back for proper maintenance. The panel shall have steel channel fabricated kick-plate and bolted type cable gland plate fitted at the bottom. The panel shall be constructed from 2 mm thick steel sheet. All the joints shall have proper gaskets. Monitoring and control devices shall be housed on the front door. Generally the construction of the panel will be such that various equipments for applications will be housed in compartments. All incoming and outgoing power and control cables shall be from the bottom. Panel will be equipped as follows:INCOMER 1 no. 3 pole, 765Amp MCCB, Set of CTs for metering INSTRUMENT 1 - Voltmeter with selector switch , 1 - Ammeter with selector switch INDICATION LAMPS, Genset Running ,Set on Load , Phase Indication. complete in all respect as desired by engineer at site:-

1

5612365

5612365

... More
Diesel Generators 1250KVA

-

-

-

... More
Supply, Erection, testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 1250 KVA/1100KW it should be air cooled/water cooled naturally aspirate d/turbo charged/ turbo charged after cool (As per manufacturer standard). DIESEL ENGINE: 12 cylinders, inline, 4 stroke cycle, Water cooled developing 1495 BHP at 1500 RPM .The engine shall be provided with electrical starting arrangement and shall give the electrical output of 1250KVA/1100KW at 0.8 power factor, 415 Volts at the alternator terminal. Other accessories of the engine would be as under: COOLING SYSTEM Radiator cooled,Engine mounted Water pump,Thermostats,Coolant,Self-contained piping, EXHAUST SYSTEM ,Exhaust manifold ,Flexible piping,Silencer - Specially designed well attenuated silencer to meet emission norms is provided FUEL SYSTEM High pressure common rail fuel system Spin on type Fuel filters Self contained piping GOVERNING SYSTEM PSO 602 Sync Capable controller LUBRICATING SYSTEM Lub Oil pump Spin on type lub oil filter Self-contained piping STARTING SYSTEM Starter, 24V, DC Battery charging Alternator With in-built Regulator AIR INTAKE SYSTEM Dry type replaceable paper element airfilter Air intake manifold with necessary connections Turbo charger OTHER SYSTEM Flywheel Flywheel housingEngine After Treatment System Along with Diesel Exhaust Fluid (DEF) Tank for Precise emission control meeting CPCB4+ Norms.

-

-

-

... More
ALTERNATOR Synchronous alternator of Leroy Somer 1250 kVA suitable for continuous operation at 1500 RPM generating 415 V at 0.8 P.F. (lag) 50 Hz, 3 phase, 4-wire system. The alternator shall be Brushless type, self-excited & self-regulated through an AVR. The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722. The salient features of the alternator are + / - 0.5% voltage regulation in static conditions.1. IP: 23 protections with class „H‟ insulation & temperature limited to class 'H' insulation limited., 2. Permanent lubricated sealed bearing., 3. Permissible overload of 10% for one hour in 12 hours of operation., 4. RTD, BTD and Space Heater , 5. Automatic Voltage Regulator.6. 4 Pole, 7. Salient pole revolving field , 8. 25% unbalance load capability, 9. Fixed disc closed couplingALTERNATOR SAFETIES 1. Under voltage 2.High voltage 3. Under frequency 4.Loss of excitation

-

-

-

... More
FEATURES 1. Industrial diesel engine with 24-volt battery charging alternator. 2. Single bearing alternator with insulation class H ,3. Inbuilt vibration isolators, 4. Dry type air filter, 5 . Multistage fuel filtration,6.Low maintenance type starting battery and battery cables,7. Digital controller 8. Exhaust flexible 9. Four-point bottom lifting,10. Remote monitoring system

-

-

-

... More
ENGINE BLOCK 1.Cast iron cylinder block with inspection door per cylinder. ,2. Cast iron cylinder liners, wet type and replaceable valves guides and seats. ,3. Separate cast iron cylinder heads with 4 valves ,4. Hardened steel forged crankshaft with induction hardened journals, crankpins and radius, 5. Lube oil cooled light alloy pistons with high performance piston rings

-

-

-

... More
COOLING SYSTEM 1.Engine front mounted radiator, 2.Thermostatically – controlled system with belt driven coolant pump, 3.Pusher fan suitable to cooling requirement ,4.Sucker fan suitable to fresh air requirement

-

-

-

... More
LUBRICATION SYSTEM 1.Full flow screw able oil filters, 2.Lube oil purifier with replaceable cartridge, 3.Water cooled lube oil cooler

-

-

-

... More
FUEL SYSTEM 1.In line fuel injection pump with flanged electronic governor , 2.Duplex file filter and water separation filter assembly with transparent cup for better efficiency.

-

-

-

... More
AIR INTAKE AND EXHAUST SYSTEM 1.Top mounted turbocharger optimized for genset application ,2.Special rear mounted air filter with restriction indicator ,3.Exhaust manifold and turbocharger shield for heat isolation.

-

-

-

... More
ENGINE SAFETIES 1.High water temperature ,2.Low lube oil pressure ,3.Over speed, 4. Low water level

-

-

-

... More
DG SET CONTROLLER The Deep Sea DSE 7320-MKII Controller is a microprocessor-based generator set monitoring, metering, and control system. The control provides an operator interface to the DG set, digital voltage regulation, digital governing, and generator set protective functions. The integration of all the functions into a single control system provides enhanced reliability and performance compared to conventional control systems.

-

-

-

... More
FEATURES Compact and Microprocessor based fully configurable control Unit 1.4-line LCD display, 2. The unique integrated DG set controller,3.Incorporate both engine and alternator, 3.parameter in one console, 4.Fully configurable digital out put, 5.All parameters are settable, 6. AMF Ready, 7. Remote Communication, 8.Remote start DISPLAY PARAMETERS:1. Engine Oil pressure,2. Coolant temperature,3. Fuel level indication %, 4. Battery voltage ,5.Engine rpm,6. DG set Running Hours,7. Generator Volts 8. 1. Phase – Neutral 2. Phase – Phase,9. Generator Current (Amps),10 Power factor

-

-

-

... More
AUDIO VISUAL WARNING & SHUTDOWN:- 1. Low Oil pressure, 2.High Coolant temperature, 3.Low Battery Voltage,4. Low fuel Level, 5. Engine Over speed,6. Engine under speed, 7.High canopy temperature, 8.Low fuel level,9.Under voltage,10 Over voltage,11 Over frequency,12 Under frequency,13 Low coolant level, 14 High Canopy Temperature

-

-

-

... More
ACOUSTIC ENCLOSURE FEATURES:  The CAPON TYPE enclosure is fabricated out of CRCA sheet.  Sheet metal thickness is 2 mm only.  The sheet metal components are hot dipped in SEVEN TANKS pre-treated before powder coating.  Enclosure colour scheme is 90% white Glossy RAL 9003 only.  Enclosure is powder coated (inside as well outside) with a special pure polyester based powder.  All Nuts and, bolt/external hardware are made from stainless steel.  The doors are gasketed with high quality EPDM gaskets to avoid leakage of sound.  The door handles are lockable type.  Sound proofing of enclosure is done with high quality rock wool/mineral wool confirming to IS 8183.  The rock wool is further covered with fiber glass cloth and perforated powder coated MS sheet.  Adequate ventilation is provided to meet air requirement for combustion and heat removal.  As per CPCB norms with acoustic enclosure / rooms noise insertion loss shall be 25dBA at 1 meter under free field conditions.

-

-

-

... More
BATTERY AND BATTERY CHARGER:  2 nos. 200 AH lead acid type low maintenance type batteries.  Inter connection battery cables.  SMPS type battery charger, The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge.

2

13049206

26098412

... More
SUB STATION SAFETY EQUIPMENT

-

-

-

... More
Supply of Rubber hand gloves suitable for 11KV. Grade As per IS4770-1963.

4

899

3596

... More
Supply & fixing of shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.

4

181

724

... More
Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

5

157

785

... More
Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.

2

5596

11192

... More
Supply of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -1963

3

2262

6786

... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.

35

2322

81270

... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.

15

3393

50895

... More
LT PANEL/DISTRIBUTION/SUB DISTRIBUTION BOARDS

-

-

-

... More
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of Main LT panel / Main distribution panels / sub-distribution panels fabricated out of 2mm thick for structural members and 1.6mm thick for door and covers CRCA sheet steel in cubicle compartmentalised free standing floor mounted, dust and vermin proof, fully bolted type (modular design) for indoor and welded type for outdoor, with reinforcement of suitable size angle iron, channel T irons and/or flats wherever necessary. Panels shall be treated with all anticorrosive process before painting with 9 stage pretreatment process and final approved shade of enamelled paint. 2Nos. earthing terminals shall be provided for all distribution panels. All covers and doors to be provided with foam sealing PU gasket with no cut and joints. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system, 10% space for future provision, lifting hooks shall also be provided in case of large panels. All panels shall be compatible to IEC 61439 Part-1 & 2 and form 4-A, Type-3.

-

-

-

... More
Approval shall be taken for each panel before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. The panels to confirm IP-42 for indoor & IP-55 for outdoor. Calculation of Bus-bar to be submitted with the drawings of panels for approval. All CPRI test report to be submitted. All internal wiring in the panels shall be carried out using high temperature FRLS wires.

-

-

-

... More
All Switchboards shall be provided with detachable gland plates for ease entry of cables from the top/bottom as required and specified.

-

-

-

... More
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars shall be insulated with heat shrinkable sleeves/as per manufacturer's type tested proven design. SMC/DMC shrouds and busbar supports suitably spaced shall be used. Hinged doors with padlocking facility shall be provided on all outgoing feeders with switch handles lockable in OFF position.

-

-

-

... More
All panels shall have provision of space @ 20% for future expansion etc.

-

-

-

... More
The panel shall have aluminium busbars and shall not be less than the (ampere) sizes mentioned/calculated after derating. The bidder will be submitted the exact calculations, which shall be based on more stringent condition. The vendor shall also make complete protection curves and discrimination chart for relay settings and shall adjust all these readings at site.

-

-

-

... More
Earthing all components, frame etc. to a common internal earth bar of minimum size 50 x 6 mm copper bar of suitable size

-

-

-

... More
All accessories & supporting structures such as channels, ISMC base frame, mounting brackets, lifting lugs, panel heaters, ventilation arrangement etc as required.

-

-

-

... More
Each incomer and outgoing feeder shall be provided with multiple LED status indication lamps suitable for 230 V, AC..

-

-

-

... More
The makes of components and accessories shall, to the extent practically feasible, be same for panels and boards for uniformity, standardisation and replaceability and shall be applicable to all panels/ boards under the scope of work

-

-

-

... More
Switchboard including interconnections, labelling, earthing, associated foundation/masonary work & erection etc. complete as required.

-

-

-

... More
All MCCBs shall be current limiting type microprocessor based, rated for requisite specified Service short circuit breaking capacity (Ics) suitable for isolation conforming to latest IEC947- 2/IS13947-2 duly marked on MCCB, at operating voltage (Ue) of 415 V, insulation voltage (Ui) 750 V and with trip free mechanism, handle, indicating On/Off/Trip position. The breaking capacity as mentioned shall be Ics values.

-

-

-

... More
All 4P MCCB has inbuilt feature of earth fault protection, whereas all TP MCCB's shall have external CT for neutral overload protection and earth fault protection

-

-

-

... More
All incoming and outgoing MCCBs shall have minimum ON/OFF/Trip indication (Red, Green, Amber) with suitable rating MCB,similarly all incoming and outgoings of main LT panel and Main emergency panel, ESR / Pump Room panels shall have potential free contacts for connectivity to PLC for ON/OFF/TRIP status and control, as required, from BMS workstation through BUSNET/MODBUS protocol

-

-

-

... More
Panel/board design shall be compact and components / accessories of compact sizes be used to economies the room space available. Employer reserve the right to seek compact items in place of larger ones

-

-

-

... More
All incomer ACB's shall be provided with minimum 2 NO + 2 NC auxiliary contacts and all MCCBs shall be provided with 2 NO + 2 NC auxiliary contacts, and there should be provision to add min. 6 Auxilary contacts.

-

-

-

... More
All 4-pole ACBs shall have fully rated neutral pole

-

-

-

... More
The panels shall be equipped with an independent clean agent / gas flooding system using linear heat sensing tubes, for fire suppression of the panel, cost of the same shall be included into the quoted price, however the scheme and calculation of the same shall be got approved with consultants before proceeding manufacturing and assembly. Also note that the tubing system doesn't affect on IP rating of the panels;

-

-

-

... More
The panel will comprise of the following :

-

-

-

... More
Main LT with Auto ON/OFF (AMF) Auto Syncronisation and Load Distribution Panel

1

14030759

14030759

... More
CAPACITOR Bank (for directly placement on each transformer)

-

-

-

... More
1 Nos. 100 A TP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 50 KA).

-

-

-

... More
1 Nos. 25 kVAr - Metallised Poly Propylene (H) type capacitor-440V

-

-

-

... More
OUTGOING (Directly taken out from One no. transformer's outgoing and other from one no. DG Sets- for Fire Panel)

-

-

-

... More
02 Nos. of 800A, TPN feeder each having one no. 3 phase, 415 volts, 50 HZ, 630 Amps.,50 kA TP+NL MCCB with required auxiliary contact,Rotary handle, spreader link, set of R-Y-B & ON-OFF indication lamps (LED type) etc.complete with all other accessories in all respects(for Fire Panel)

-

-

-

... More
Incoming

-

-

-

... More
02 Nos., 3 phase, 415V, 50 Hz, 2500 Amps Electrically Draw Out type FP 50 KA ACB with microprocessor based O/L, E/F, S/C, Inst.S/C releases, suitable ratings Dual Ratio metering CT's, Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, phase indicating lamps, Set of RYB indications lamps(LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects. (for 2 nos. 1600 KVA Transformer)

-

-

-

... More
02 Nos., 3 phase, 415V, 50 Hz, 2000 Amps Electrically Draw Out type FP 50 KA ACB with microprocessor based O/L, E/F, S/C, Inst.S/C releases, suitable ratings Dual Ratio metering CT's, Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, phase indicating lamps, Set of RYB indications lamps(LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects. (for 2 nos. 1250 KVA DG Set)

-

-

-

... More
01 Nos., 3 phase, 415V, 50 Hz, 800 Amps Electrically Draw Out type FP 50 KA ACB with microprocessor based O/L, E/F, S/C, Inst.S/C releases, suitable ratings Dual Ratio metering CT's, Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, phase indicating lamps, Set of RYB indications lamps(LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects (for 1 nos. 500 KVA DG Set)

-

-

-

... More
01 Nos., 3 phase, 415V, 50 Hz, 630 Amps Electrically Draw Out type FP 50 KA ACB with microprocessor based O/L, E/F, S/C, Inst.S/C releases, suitable ratings Dual Ratio metering CT's, Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, phase indicating lamps, Set of RYB indications lamps(LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects.(for 1 no. 100 Kwph Solar/ Battery Power)

-

-

-

... More
BUSBARS

-

-

-

... More
2 Sets of 4000 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy after taking all derating and neutral rated for amps and these rating shall be after derating.(A derating factor of 0.66 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. The conductivity of bus bar shall not be less than 55%) and earth bus size shall be 10%.

-

-

-

... More
BUS COUPLER

-

-

-

... More
01 No., 3 phase, 415V, 50 Hz, 2500 Amps Electrically Draw Out type FP 50 KA ACB with microprocessor based O/L, E/F, S/C, Inst.S/C releases, suitable ratings Dual Ratio metering CT's, Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, phase indicating lamps, Set of RYB indications lamps(LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects.

-

-

-

... More
INSTRUMENTS

-

-

-

... More
2 nos. Microprocessor based controller (inteliMains 1010 of ComAp make or equivalent as per approved list of makes) enough capable to synchronise Main (Grid) supply with 3 nos. DG Set & 1 no. Solar Power Supply with minimum delay and smooth deloading. (for transformers only)

-

-

-

... More
1 nos. Microprocessor based controller (inteliMains 510 of ComAp make or equivalent as per approved list of makes) enough capable to synchronise 2 nos. Main (Grid) supply transformers with 3 nos. DG Set & 1 no. Solar Power Supply with minimum delay and smooth deloading. (for bus coupler only)

-

-

-

... More
3 nos. Microprocessor based controller (inteliMains 500 of ComAp make or equivalent as per approved list of makes) enough capable to synchronise 2 nos. Main (Grid) supply transformers with 3 nos. DG Set & 1 no. Solar Power Supply with minimum delay and smooth deloading. (for DG sets only)

-

-

-

... More
1 nos. Microprocessor based controller (inteliNEO 5500/6000 of ComAp make or equivalent as per approved list of makes) enough capable to synchronise 2 nos. Main (Grid) supply transformers with 3 nos. DG Set & 1 no. Solar Power Supply with minimum delay and smooth deloading. (for Solar Power only)

-

-

-

... More
Lot of control wiring.

-

-

-

... More
Set of designation plates.

-

-

-

... More
Interlocking logic electrical

-

-

-

... More
Other items such as:-

-

-

-

... More
Illumination light interlocked with doors.

-

-

-

... More
Suitable Nos. and dia of Exhaust Fan with Temp. rise thermostat.

-

-

-

... More
OUTGOINGS

-

-

-

... More
4 Nos. 3 phase 415 Volts, 1600A, FP, 50 kA, electrically operated drawout type ACB with Microprocessor based O/L, E/F, S/C, Inst.S/C releases, suitable ratings Dual Ratio metering CT's, Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, phase indicating lamps, Set of RYB indications lamps(LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects.

-

-

-

... More
2 Nos. 3 phase 415 Volts, 1250A, FP, 50 kA, electrically operated drawout type ACB with Microprocessor based O/L, E/F, S/C, Inst.S/C releases, suitable ratings Dual Ratio metering CT's, Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, phase indicating lamps, Set of RYB indications lamps(LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects.

-

-

-

... More
3 Nos. 3 phase 415 Volts, 800A, FP, 50 kA, electrically operated drawout type ACB with Microprocessor based O/L, E/F, S/C, Inst.S/C releases, suitable ratings Dual Ratio metering CT's, Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, phase indicating lamps, Set of RYB indications lamps(LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects.

-

-

-

... More
3 Nos. 3 phase 415 Volts, 250A, TP+NL, 50 kA, MCCB with Microprocessor based O/L, E/F, S/C, Inst.S/C releases, phase indicating lamps of RYB indications (LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects.

-

-

-

... More
4 Nos. 3 phase 415 Volts, 125A, TP+NL, 50 kA, MCCB with Microprocessor based O/L, E/F, S/C, Inst.S/C releases, phase indicating lamps of RYB indications (LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects.

-

-

-

... More
1 Nos. 3 phase 415 Volts, 100A, TP+NL, 50 kA, MCCB with Microprocessor based O/L, E/F, S/C, Inst.S/C releases, phase indicating lamps of RYB indications (LED types), Set of On/Off/Trip indications lamps(LED types) etc. complete with all other accessories in all respects.

-

-

-

... More
CAPACITOR PANEL

-

-

-

... More
Automatic Capacitor Panel of total 400 kVAR capacity, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extensible on both sides, with provision for capacitor mounted inside the panel with adequate number of louvers and natural cooling units,Axial flow fans with thermostats for ventilation, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc., including supply & installation of following switchgears, metering instruments and accessories in the LT Panel and as per specifications.

-

-

-

... More
BUSBARS

-

-

-

... More
1 Sets of 1000 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy after taking all derating and neutral rated for amps and these rating shall be after derating.(A derating factor of 0.66 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. The conductivity of bus bar shall not be less than 55%) and earth bus size shall be 10%.

-

-

-

... More
INSTRUMENTS

-

-

-

... More
1 no. Digital Multifunction Meters with RS485 having metering type e.g. Avg. Current, Voltage, Demand Current, Phase Current, Phase Voltages, Apparent Power, Unbalance Current, Active, reactive, Apparent Energy, Demand Power, Peak Demand Current, Calculated Neutral Current, Peak Demand Power, reactive Power, Unbalnce Voltage, Power Factor and Displacement PF, Active and Reactive Power, Active and Reactive Energy and upto the 15th Harmonic, with suitable rating dual ration CT complete with all other accessories in all respects.

-

-

-

... More
1 Set of Microprocessor based intelligent, 10 step APFC relay with PF display

-

-

-

... More
1 Set of LED type ON OFF Push button,

-

-

-

... More
1 Set of Auto/manual selector switch.

-

-

-

... More
1 Lot of control wiring.

-

-

-

... More
1 Set of designation plates.

-

-

-

... More
Interlocking logic electrical & mechanical

-

-

-

... More
Other items such as:-

-

-

-

... More
Illumination light interlocked with doors.

-

-

-

... More
Suitable Nos. and dia of Exhaust Fan with Temp. rise thermostat.

-

-

-

... More
OUTGOING

-

-

-

... More
02 Nos. 250 A TP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25 KA).

-

-

-

... More
02 Nos. 125 A TP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25 KA).

-

-

-

... More
03 Nos. 100 A TP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25 KA).

-

-

-

... More
01 Nos. 63 A TP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25 KA).

-

-

-

... More
02 Nos. 20 A TP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25 KA).

-

-

-

... More
02 Nos. 200 A TP capacitor duty contactor suitable for 50 kVAr capacitor with illuminated ON OFF push buttons (LED type).

-

-

-

... More
02 Nos. 110 A TP capacitor duty contactor suitable for 50 kVAr capacitor with illuminated ON OFF push buttons (LED type).

-

-

-

... More
03 Nos. 70 A TP capacitor duty contactor suitable for 25 kVAr capacitor with illuminated ON OFF push buttons (LED type).

-

-

-

... More
1 Nos. 40 A TP capacitor duty contactor suitable for 25 kVAr capacitor with illuminated ON OFF push buttons (LED type).

-

-

-

... More
02 Nos. 16 A TP capacitor duty contactor suitable for 25 kVAr capacitor with illuminated ON OFF push buttons (LED type).

-

-

-

... More
02 Nos. 100 kVAr - Metallised Poly Propylene (H) type capacitor-440V

-

-

-

... More
02 Nos. 50 kVAr - Metallised Poly Propylene (H) type capacitor-440V

-

-

-

... More
03 Nos. 25 kVAr - Metallised Poly Propylene (H) type capacitor-440V

-

-

-

... More
1 Nos. 15 kVAr - Metallised Poly Propylene (H) type capacitor-440V

-

-

-

... More
2 Nos. 5 kVAr - Metallised Poly Propylene (H) type capacitor-440V

-

-

-

... More
ATS (AUTO TRANSFER SWITCH)

-

-

-

... More
1 nos. 800 Amps. 415V, 50Hz , 3 Phase Ac Supply Automatic Transfer Switch (ATS), with intelligent Auto Transfer Switch complete with Electrical Protection ( Uv, Ov, Uf, Of & Single Phase Missing) Inbuilt Source Healthy And Load Status Indication For Source I And Source Ii. 2. Manual Mode Operation During Electrically Failure 3. Ac 32-B Utilization Category (Applicable For All Type Of Loads) 4. High Short Circuit Withstand Capacity Design 5. Inbuilt Auto/Manual Selection Option 6. Fire Linkage Protection. (for Fire Pump Panel)

1

364579

364579

... More
1 nos. 250 Amps. 415V, 50Hz , 3 Phase Ac Supply Automatic Transfer Switch (ATS), with intelligent Auto Transfer Switch complete with Electrical Protection ( Uv, Ov, Uf, Of & Single Phase Missing) Inbuilt Source Healthy And Load Status Indication For Source I And Source Ii. 2. Manual Mode Operation During Electrically Failure 3. Ac 32-B Utilization Category (Applicable For All Type Of Loads) 4. High Short Circuit Withstand Capacity Design 5. Inbuilt Auto/Manual Selection Option 6. Fire Linkage Protection. (for SPDB-LIFT)

1

163136

163136

... More
1 nos. 125 Amps. 415V, 50Hz , 3 Phase Ac Supply Automatic Transfer Switch (ATS), with intelligent Auto Transfer Switch complete with Electrical Protection ( Uv, Ov, Uf, Of & Single Phase Missing) Inbuilt Source Healthy And Load Status Indication For Source I And Source Ii. 2. Manual Mode Operation During Electrically Failure 3. Ac 32-B Utilization Category (Applicable For All Type Of Loads) 4. High Short Circuit Withstand Capacity Design 5. Inbuilt Auto/Manual Selection Option 6. Fire Linkage Protection. (for SPDB-UPS)

1

102053

102053

... More
SPDB (SUB POWER DISTRIBUTION BOARDS)

11

487190

5359090

... More
Incoming

-

-

-

... More
01 Nos. 400 Amp TPN Moulded Case Circuit Breaker with Microprocessor based release having adjustable over load and adjustable short circuit, auxiliary contactors, Cast Resin CTs and shunt trip (Ics=100%Icu, 35 KA).

-

-

-

... More
Bus bar

-

-

-

... More
Set of 600 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy after taking all derating and neutral rated for amps and these rating shall be after derating.(A derating factor of 0.66 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. The conductivity of bus bar shall not be less than 55%) and earth bus size shall be 10%.

-

-

-

... More
Outgoings

-

-

-

... More
02 Nos. 3 phase 415Volt, 250A, 25kA, TP MCCB complete with all other accessories..

-

-

-

... More
02 Nos. 3 phase 415Volt, 125A, 25kA, TP MCCB complete with all other accessories..

-

-

-

... More
08 Nos. 3 phase 415Volt, 100A, 25kA, TP MCCB complete with all other accessories..

-

-

-

... More
SPDB - UPS

1

344760

344760

... More
Incoming

-

-

-

... More
1 Nos. 125 Amps FP feeder each having one number 3 phase 415 Volts, 50 Hz, 25 KA front operated 125 Amps.FP MCCB with require auxiliary contacts etc. complete in all respects.

-

-

-

... More
Bus bar

-

-

-

... More
1 set of 400 Amps, 415 volts, 3 phase, 4 wire colour coded TPN aluminium bus bar, after taking all derating factors.

-

-

-

... More
Outgoings

-

-

-

... More
06 Nos. 3 phase 415Volt, 100A, 25kA, TP MCCB complete with all other accessories..

-

-

-

... More
06 Nos. 3 phase 415Volt, 63A, 25kA, TP MCCB complete with all other accessories..

-

-

-

... More
SPDB-LIFT

2

266964

533928

... More
Incoming

-

-

-

... More
1 Nos. 250 Amps FP feeder each having one number 3 phase 415 Volts, 50 Hz, 25 KA front operated 250 Amps.FP MCCB with require auxiliary contacts etc. complete in all respects.

-

-

-

... More
Bus bar

-

-

-

... More
1 Sets of 400 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy after taking all derating and neutral rated for amps and these rating shall be after derating.(A derating factor of 0.66 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. The conductivity of bus bar shall not be less than 55%) and earth bus size shall be 10%.

-

-

-

... More
Outgoings

-

-

-

... More
08 Nos. 3 phase 415Volt, 100A, 25kA, TP MCCB complete with all other accessories..

-

-

-

... More
SDB-LIFT:

12

75430

905160

... More
Incoming:

-

-

-

... More
1 Nos. 100 Amps TPN feeder each having one number 3 phase 415 Volts, 50 Hz, 25 KA front operated 100 Amps.TP+NL MCCB with require auxiliary contacts etc. complete in all respects.

-

-

-

... More
Bus Bar

-

-

-

... More
1 set of 160 Amps, 415 volts, 3 phase, 4 wire colour coded FP aluminium bus bar, after taking all derating factors.

-

-

-

... More
Outgoing

-

-

-

... More
1 No. 63 Amps FP feeder each having one number 3 phase 415 Volts, 50 Hz, 100mA, FP front operated 63 Amps. 4P RCBO.

-

-

-

... More
1 Nos. 32 Amps. 10 KA FP MCB (for Lift Pressurisation Fan) Note:- Pressurisation fan starter shall be functional on receipt of signal from Fire Alarm Control Panel, hence Aux. Contactor, Selector switch & push button, FS Cable control wiring etc. be included into quoted prices and be the part of panel.

-

-

-

... More
06 Nos. 6-32 Amps. 10 KA SP MCB.

-

-

-

... More
Incoming

-

-

-

... More
1 Nos. 100 Amps TPN feeder each having one number 3 phase 415 Volts, 50 Hz, 25 KA front operated 100 Amps.TP+NL MCCB with require auxiliary contacts etc. complete in all respects.

-

-

-

... More
0-24 Hrs astronomical timer with suitable rating contactor for auto ON/Off Extn Lighting.

-

-

-

... More
Outgoing

-

-

-

... More
36 Nos.6A~20 A SP MCB spreaded in three rows

-

-

-

... More
Bus bars

-

-

-

... More
1 set of 415 V 3 phase 4 wire, 50 HZ Colour coded copper bus bars.

-

-

-

... More
Neutral Link

-

-

-

... More
Suitable for all outgoings.

-

-

-

... More
Earthing Terminals.

-

-

-

... More
Earthing terminals suitable for all outgoing.

-

-

-

... More
Incoming

-

-

-

... More
1 Nos. 100 Amps TPN feeder each having one number 3 phase 415 Volts, 50 Hz, 25 KA front operated 100 Amps.TP+NL MCCB with require auxiliary contacts etc. complete in all respects.

-

-

-

... More
Outgoing

-

-

-

... More
36 Nos.6A~20 A SP MCB spreaded in three rows

-

-

-

... More
Bus bars

-

-

-

... More
1 set of 415 V 3 phase 4 wire, 50 HZ Colour coded copper bus bars.

-

-

-

... More
Neutral Link

-

-

-

... More
Suitable for all outgoings.

-

-

-

... More
Earthing Terminals.

-

-

-

... More
Earthing terminals suitable for all outgoing.

-

-

-

... More
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:

-

-

-

... More
CUBICAL PEDESTAL:

-

-

-

... More
Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable with 4no. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth to be erected in the 1:2:4 cement concrete mixture, the platform of 150mm high from ground level & 450mm thick & 150mm from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-

-

-

-

... More
Cubical Size 1200mm high, 1800mm wide and 350mm deep with Platform Dimention 1900mmx450mmx450mm

12

29984

359816.64

... More
TIMER:

-

-

-

... More
S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre- fixed timings complete in all respect as per satisfaction of Engineer-in-charge:-

-

-

-

... More
Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C- Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)

12

15361

184332.96

... More
MCCB'S (FOR PANELS & SHEET ENCLOSURE):

-

-

-

... More
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (Conforms to IEC:60947-2) having Ics=100%, Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of thimbles etc:- Make: L&T (D-sine), ABB (T-MAX), Schneider (CVS), Hager (H3), Legrend (DPS), Havells (Loadline) or equivalent.

-

-

-

... More
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

12

7744

92936.4

... More
METER BOARDS

-

-

-

... More
Supplying, installation, testing and commissioning of cubical type meter board facricated out of 2mm thick MS sheet, dust and vermin proof, with hinged detachable doors and painted front, connecting through suitable size bus bar links with an existing mounted Tap off Box mounted directly on the rising Main, suitable size Cu. cable complete with terminal links etc. to be provided to connect incoming size of an energy meter, (installed at later date) as an incomers The work include making connections, fixing at designated location, testing and commissioning including earthing complete as required.

-

-

-

... More
The meter boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall be provided in case of large boards. Boards shall be fabricated in easily transportable sections & length, height, depth etc to match with site conditions. An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shall be used in fabrication of boards.The meter board shall be totally factory assembled with MCB, MCCB, wiring etc. and an approval shall be taken for each panel before manufacturing.

-

-

-

... More
METER BOARDS

14

316511

4431154

... More
Incomer

-

-

-

... More
1 No. 250 Amps TPN feeder each having one number 3 phase 415 Volts, 50 Hz, 25 KA front operated 250 Amps.TP MCCB with isolable neutral, complete in all respects.

-

-

-

... More
Bus Bars

-

-

-

... More
400 A FP aluminium Bus Bars with heat shrinkable coloured insulated PVC sleeves. (Current density of Bus bar shall be 1.2 sq.mm./amp)

-

-

-

... More
Outgoings

-

-

-

... More
12 nos. Sufficent size independent Compartment with lockable facilities suitable for 10 Nos. Single phase Dual Source Prepaid Energy Meter with all necessary wiring including MS sheet support for meter fixing having sufficent size windows for meter reading covered from glass, including supply & fixing of 10 nos. 63A, 10KA 4P MCB's required wiring from bus bars to meter & meter to MCB's., including earthing, Terminal block for looping DC supply to each meter within meter board. (Cost of meter shall be paid seprately in a different item)

-

-

-

... More
ELECTRONIC ENERGY METERS AND REVENUE COLLECTION SYSTEM

162

13015

2108430

... More
Supply, installation, testing and commissioning of 3 phase, 4 wire, 50 Hz, dual register, pre paid type electronic energy meters (As per IS : 15884 - 2010) and revenue collection system with key pad technology along with blue tooth enabled home display / freedom units having LCD display, lithium battery with inbuilt facility of tripping and resetting of over loading in case of D.G.power at preset level, provision of change of tarrif as per customer's requirements and as per manufacturers specifications. The Meter should have inbuild disconnect switches as per BIS requirement with over load and low balance alarm facility,Slab or TOD (Time of use) traiffs upto 4 rates and one year energy data backup. The meter should be capable for full or partial backup for one whole year,. (Note: Quoted Prices shall include 3 (2+1) pair flat telephone cable, run from meter to each unit for freedom units), Meter & system Equivalent to Secure-Liberty or as per makes list.

-

-

-

... More
Supply, installation, testing and commissioning of common meter reading instrument (CPRI) complete in all respects.

5

48068

240340

... More
Supply, installation, testing and commissioning of DG sensing switch mode power supply unit with discrimination receivers for sensing of DG (SMPS and necessary lengths of PVC insulated armoured copper conductor 2c x 2.5 sq mm control wiring for DG power registration in electronic meters. The control wiring shall run between D.G. panel to each block seperately. The control wiring shall be connected to each meter. OR, Supply, installation, testing and commissioning of mains sensing power line carrier communication (PLCC) based source discrimination receivers of sensing of mains of suitable MVA rating. (SIGNAL INJECTOR)

3

412500

1237500

... More
Supply, installation, testing and commissioning of necessary vending software and data base designing alongwith a one set of Intel Core 2 Duo level or higher PC with 1 GB RAM and 500 GB HDD with laser printer complete in all respects.

162

813

131706

... More
Supply, installation, testing and commissioning of impact token printer with serial port, coplete in all respects.

1

27362

27362

... More
Supply, installation, testing and commissioning of full functioning of system and ready for collection of revenues. The charges will include for necessary training of vending system to operator and customers upto full satisfaction.

1

961

961

... More
SUBMAINS, CABLES AND CABLE TERMINATIONS ETC.

-

-

-

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND):

-

-

-

... More
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-

-

-

-

... More
Overall size 400sq.mm (31⁄2 Core) Armoured (Underground)

1500

2117

3176310

... More
Overall size 300sq.mm (31⁄2 Core) Armoured (Underground)

2100

1764

3705681

... More
Overall size 240sq.mm (31⁄2 Core) Armoured (Underground)

56

1524

85396.64

... More
Overall size 185sq.mm (31⁄2 Core) Armoured (Underground)

10

1281

12813.2

... More
Overall size 150sq.mm (31⁄2 Core) Armoured (Underground)

15

1114

16711.2

... More
Overall size 120sq.mm (31⁄2 Core) Armoured (Underground)

40

1008

40349.2

... More
Overall size 95sq.mm (31⁄2 Core) Armoured (Underground)

140

858

120204

... More
Overall size 70sq.mm (31⁄2 Core) Armoured (Underground)

360

778

280177.2

... More
Overall size 50sq.mm (31⁄2 Core) Armoured (Underground)

170

667

113502.2

... More
Overall size 35sq.mm (31⁄2 Core) Armoured (Underground)

300

603

180939

... More
Overall size 25sq.mm (4Core) Armoured (Underground)

600

571

342912

... More
Overall size 16sq.mm (4Core) Armoured (Underground)

2300

530

1220610

... More
Overall size 10sq.mm (4Core) Armoured (Underground)

60

516

30973.2

... More
XLPE INSULATED ARMOURED CABLES (LOOSE):

-

-

-

... More
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-

-

-

-

... More
Overall size 400sq.mm (31⁄2 Core) Armoured (Loose)

200

1729

345812

... More
Overall size 300sq.mm (31⁄2 Core) Armoured (Loose)

400

1376

550452

... More
Overall size 240sq.mm (31⁄2 Core) Armoured (Loose)

30

1136

34093.8

... More
Overall size 185sq.mm (31⁄2 Core) Armoured (Loose)

5

895

4477.4

... More
Overall size 150sq.mm (31⁄2 Core) Armoured (Loose)

5

728

3641.15

... More
Overall size 120sq.mm (31⁄2 Core) Armoured (Loose)

10

622

6228.8

... More
Overall size 95sq.mm (31⁄2 Core) Armoured (Loose)

45

487

21925.8

... More
Overall size 70sq.mm (31⁄2 Core) Armoured (Loose)

95

408

38781.85

... More
Overall size 50sq.mm (31⁄2 Core) Armoured (Loose)

122

297

36308.42

... More
Overall size 35sq.mm (31⁄2 Core) Armoured (Loose)

196

233

45685.64

... More
Overall size 25sq.mm (4Core) Armoured (Loose)

177

202

35895.6

... More
Overall size 16sq.mm (4Core) Armoured (Loose)

267

161

43248.66

... More
Overall size 10sq.mm (4Core) Armoured (Loose)

20

146

2923.4

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):

-

-

-

... More
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-

-

-

-

... More
Overall size 400sq.mm (31⁄2 Core) Armoured (On-Surface)

2000

1776

3552920

... More
Overall size 300sq.mm (31⁄2 Core) Armoured (On-Surface)

6000

1422

8533380

... More
Overall size 240sq.mm (31⁄2 Core) Armoured (On-Surface)

138

1182

163191.9

... More
Overall size 185sq.mm (31⁄2 Core) Armoured (On-Surface)

25

929

23242.75

... More
Overall size 150sq.mm (31⁄2 Core) Armoured (On-Surface)

40

761

30446

... More
Overall size 120sq.mm (31⁄2 Core) Armoured (On-Surface)

70

657

45998.4

... More
Overall size 95sq.mm (31⁄2 Core) Armoured (On-Surface)

400

512

204904

... More
Overall size 70sq.mm (31⁄2 Core) Armoured (On-Surface)

1000

431

431940

... More
Overall size 50sq.mm (31⁄2 Core) Armoured (On-Surface)

400

321

128528

... More
Overall size 35sq.mm (31⁄2 Core) Armoured (On-Surface)

800

256

205432

... More
Overall size 25sq.mm (4 Core) Armoured (On-Surface)

1900

225

427861

... More
Overall size 16sq.mm (4 Core) Armoured (On-Surface)

7000

184

1290520

... More
Overall size 10sq.mm (4 Core) Armoured (On-Surface)

180

169

30578.4

... More
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-

-

-

-

... More
Brass Gland for Aluminium cable 2/3/31⁄2/4 Core size 25-35sq.mm

108

144

15564.96

... More
Brass Gland for Aluminium cable 2/3/31⁄2/4 Core size 50sq.mm

8

179

1436.16

... More
Brass Gland for Aluminium cable 3/31⁄2/4 Core size 70sq.mm

46

190

8780.94

... More
Brass Gland for Aluminium cable 3/31⁄2/4 Core size 95-120sq.mm

32

251

8050.56

... More
Brass Gland for Aluminium cable 3/31⁄2/4 Core size 150sq.mm

12

293

3519.48

... More
Brass Gland for Aluminium cable 3/31⁄2/4 Core size 185sq.mm

6

347

2085.96

... More
Brass Gland for Aluminium cable 3/31⁄2/4 Core size 240sq.mm

12

450

5400.72

... More
Brass Gland for Aluminium cable 3/31⁄2/4 Core size 300sq.mm

64

514

32929.92

... More
Brass Gland for Aluminium cable 3/31⁄2/4 Core size 400sq.mm

36

639

23028.84

... More
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-

-

-

-

... More
Aluminium thimble cable Core size 4 - 6sq.mm

71

13

972.7

... More
Aluminium thimble cable Core size 10 - 16sq.mm

108

14

1593

... More
Aluminium thimble cable Core size 25 - 35sq.mm

394

17

7056.54

... More
Aluminium thimble cable Core size 50sq.mm

56

28

1592.64

... More
Aluminium thimble cable Core size 70sq.mm

12

31

379.32

... More
Aluminium thimble cable Core size 95sq.mm

240

36

8848.8

... More
Aluminium thimble cable Core size 120sq.mm

12

45

543.6

... More
Aluminium thimble cable Core size 150sq.mm

100

54

5478

... More
Aluminium thimble cable Core size 185sq.mm

54

65

3527.28

... More
Aluminium thimble cable Core size 240sq.mm

36

105

3792.6

... More
Aluminium thimble cable Core size 300sq.mm

192

122

23464.32

... More
Aluminium thimble cable Core size 400sq.mm

108

165

17863.2

... More
CABLE TRAY AND FLOOR RACEWAYS ETC.

-

-

-

... More
Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc. complete in all respect as desired by the Engineer-in-charge as per PWD General Specifications:-

-

-

-

... More
Cable Tray Size 150mm x 50mm x 50mm (2mm thick)

600

1066

639810

... More
Cable Tray Size 300mm x 50mm x 50mm (2mm thick)

1600

1455

2329168

... More
Cable Tray Size 450mm x 50mm x 50mm (2mm thick)

300

1902

570786

... More
FLOOR RACE WAYS

-

-

-

... More
Supply and fixing of following size of under floor GI raceways for distributing cabling in screed floor installations. Raceway should be made up of Pre galvanized sheet with minimum thickness of 1.6 mm consist of body and cover. It should have average of 275GSM zinc coating. Raceway should be supplied with required accessories such as fixing brackets and coupling plates as required. Raceway should be confirmed with the standard EN 50085-2-2 including all accessories complete as required.

-

-

-

... More
100 mm wide x 38 mm deep raceway (1 compartment)

50

3542

177100

... More
SITC of Fixing Bracket of 100mmX38mm

100

66

6600

... More
SITC of Coupling 38

50

133

6650

... More
Supply and fixing of following size of Height adjustable under floor /crossover Junction box with flyover for Raceways for direct access to cables at the intersection of Raceways supplied completely with base and cover plate(lid). Junction box should be made of Pre galvanized sheet consist of body and cover. Height of the junction box should be adjustable from minimum 60mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site. It should be confirmed with the standard EN 50085-2-2s including all accessories complete as required:

-

-

-

... More
Adjb. Flyover 225X255X65-90mm

10

3413

34130

... More
MCB/MCB DISTRIBUTION BOARDS

-

-

-

... More
MINIATURE CIRCUIT BREAKERS:

-

-

-

... More
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1,energy limitation class-3, true contactindication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-

-

-

-

... More
MCB Single Pole 6-32amp. (10kA, Curve-C)

1856

190

353716.48

... More
MCB Double Pole 6-32amp. (10kA, CurveC)

1

580

580.27

... More
MCB Double Pole 40amp. (10kA, CurveC)

90

789

71039.7

... More
MCB Double Pole 50, 63amp. (10kA, Curve-C)

2

930

1860.28

... More
MCB Triple Pole 6-32amp. (10kA, CurveC)

40

860

34418

... More
MCB Triple Pole 40amp. (10kA, CurveC)

35

1188

41614.3

... More
MCB Triple Pole 50, 63amp. (10kA, Curve-C)

43

1325

56996.93

... More
MCB Four Pole 6-32amp. (10kA, CurveC)

2

1186

2372.28

... More
MCB Four Pole 40amp. (10kA, CurveC)

2

1531

3063.48

... More
MCB Four Pole 50, 63amp. (10kA, Curve-C)

2

1750

3501.52

... More
RCBO's:

-

-

-

... More
Supply and erection of RCBO 'Residual Current Breaker Overload' for earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10 kA as per 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-

-

-

-

... More
RCBO Double Pole 40 amp.,Sensitivity 100/300mA

90

3721

334962

... More
RCBO Double Pole 63amp., Sensitivity 100/300mA

2

4573

9147.02

... More
RCBO Four Pole 40amp., Sensitivity 100mA

35

4145

145104.4

... More
RCBO Four Pole 63amp., Sensitivity 100mA

43

4707

202443.57

... More
RCCB Four Pole 63amp.,Sensitivity 100mA

120

2983

358078.8

... More
MCCB's (MOULDED CASE CIRCUIT BREAKER):

-

-

-

... More
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:

-

-

-

... More
MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

15

12864

192961.2

... More
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's:

-

-

-

... More
Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-

-

-

-

... More
SP&N Double Door Distribution Board 12 way each

92

1797

165406.8

... More
SP&N Double Door Distribution Board 16 way each

2

2163

4327.56

... More
TP&N Horizontal Double Door Distribution Board 4 way each

35

2914

102022.55

... More
TP&N Horizontal Double Door Distribution Board 6 way each

6

3592

21553.02

... More
TP&N Horizontal Double Door Distribution Board 8 way each

16

4288

68620.8

... More
TP&N Horizontal Double Door Distribution Board 12 way each

20

5948

118971.8

... More
AC Plug and Socket SP&N with provision of One Single Pole MCB 20amp.

12

880

10569.36

... More
AC Plug and Socket TP&N with provision of One Triple Pole MCB 20amp.

45

1761

79270.2

... More
AC Plug and Socket TP&N with provision of One Triple Pole MCB 30/32amp

90

2415

217420.2

... More
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1 3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos shrouded neutral bars, 2Nos.earth bars,cement spill protector,color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-

-

-

-

... More
TP&N Double Door Vertical DB's 12 way each (With provision of FP MCCB 250amp.)

23

17128

393956.42

... More
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-

-

-

-

... More
Cable End Box for TPN Vertical 4/8/12Way

23

1802

41453.59

... More
Cable End Box for TPN 12 Way

20

1668

33362.2

... More
Cable End Box for TPN 8 Way

16

1373

21978.56

... More
Cable End Box for TPN 6 Way

6

1206

7239.42

... More
Cable End Box for TPN 4 Way

35

1072

37532.6

... More
Cable End Box for SPN 16 Way

2

864

1728.38

... More
Cable End Box for SPN 12 Way

92

799

73583.44

... More
POINT WIRING

-

-

-

... More
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100 volts grade to be laid in heavy gauge welded conduit pipe 20mm/25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring fan point (With fan box)

268

1594

427234.88

... More
Wiring light point

931

1122

1045149.91

... More
Wiring 6Amp. wall socket point

402

844

339484.98

... More
Wiring 16/20Amp. power plug control point

409

553

226471.48

... More
Wiring light point without control switch.

2876

542

1559769.84

... More
Wiring light point with double control switches.

20

2031

40631.4

... More
Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.

73

826

60355.67

... More
Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).

10

707

7079.5

... More
Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets,Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc.,including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring TV socket point (one module)

183

353

64778.34

... More
Wiring Telephone socket point RJ11 (one module)

183

355

65008.92

... More
Wiring Networking socket point RJ45 (one module)

183

461

84441.69

... More
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 1sq.mm (Un-sheathed)

5500

19

105435

... More
Overall size 1.5sq.mm (Un-sheathed)

3200

24

78880

... More
Overall size 2.5sq.mm (Un-sheathed)

8500

36

314330

... More
Overall size 4.0sq.mm (Un-sheathed)

4000

53

213640

... More
Overall size 6.0sq.mm (Un-sheathed)

100

73

7396

... More
Overall size 10sq.mm (Un-sheathed)

150

120

18078

... More
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 1.5sq.mm (48/0.20mm), 3Core

350

67

23488.5

... More
Overall size 2.5sq.mm (50/0.25mm), 3Core

300

104

31227

... More
Overall size 4.0sq.mm (84/0.3mm), 3Core

100

154

15476

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES:

-

-

-

... More
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, MS saddle clamps and other petty materials etc., as per PWD General Specifications:-

-

-

-

... More
Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)

7000

57

402640

... More
Heavy Gauge PVC Conduit Pipe 32mm dia.(On Surface)

1000

87

87020

... More
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)

12000

70

849600

... More
Heavy Gauge PVC Conduit Pipe 50mm dia. (Flushed)

2500

176

442475

... More
LIGHT FITTINGS/FIXTURES,FANS AND EXH.FANS

-

-

-

... More
Supply, installation, testing and commissioning of surface mounted indoor duty (IP-65) 4 feet long 36 W LED Linear Low Bay energy efficient single colour temperature strip suitable to distribute light spaciously along both the vertical and horizontal workspace. The luminaire shall have an integral sensor to control switching light output as per pre-set scenario. The certification , Specifications and warranty of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

730

5177

3779210

... More
Supply, installation, testing and commissioning of surface mounted indoor duty (IP-20) circular shape 15W LED fixture. The luminaire shall have an integral sensor to control switching light output as per pre-set scenario. The certification , Specifications and warranty of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

1401

3106

4351506

... More
Supply, installation, testing and commissioning of recessed mounted indoor duty (IP-20) circular shape 10W energy efficient single colour temperature LED fixture. The luminaire shall have an integral sensor to control switching light output as per pre-set scenario. r. The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

168

2692

452256

... More
Supply, installation, testing and commissioning of Recessed Mounted LED Circular Downlighter 10W ±10% . . The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

569

2692

1531748

... More
Supply, installation, testing and commissioning of Surface Mounted LED Circular Downlighter suitable, having system wattage as 12W ±10%. The certification , Specifications and warranty of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

10

3727

37270

... More
Supply, installation, testing and commissioning of Recessed Mounted COB LED Circular Dali Dimmable Downlighter 30W/40W (±10%). The certification , Specifications and warranty of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

10

7025

70250

... More
Supply, installation, testing and commissioning of LED Batten luminaire having wattage 40W (±10%). The luminaire shall be suitable for Wall / conduit / suspended / surface mounting.The certification , Specifications and warranty of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

1481

5177

7667137

... More
Supply, installation, testing and commissioning of 1 phase, 240 V, 50 Hz, Ceiling suspended Up-Down type mirror optics Dali Dimmable LED chanel light 28W (±10%) and (in 4ft length) . The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

16

3106

49696

... More
Supply, installation, testing and commissioning of Decorative Surface Mounted LED mirror light 20W (±10%). .The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

48

3313

159024

... More
Supply, installation, testing and commissioning of surface Mounted Bulk Head (IP-65) light with high efficient 10 Watt LED and milky diffuser. The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

72

2485

178920

... More
Supply, installation, testing and commissioning of 1 phase, 240 V, 50 Hz, Surface Mounted 5 watt LED Brick Light / Step Light fixtures complete as per standard item with copper wiring lamps as requiredThe electronic driver used shall have a power factor 0.3 with THD 250%.. .The certification , Specifications and warranty of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

10

4141

41410

... More
Supply, installation, testing and commissioning of 5 watt, 120 LED/per meter LED type flexible strip light (total length 5 Meter) for Indoor lighting complete with 1 nos power supply unit /driver of suitable rating, duly wired, suitable for single phase cable etc.complete system as required. The IP20 rating LED STRIP WH and the IP20 driver. (considering 25W each driver per 5m role). .The certification , Specifications and warranty of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

2460

547

1345620

... More
Supply, installation, testing and commissioning of LED Batten luminaire 18/20W T5 Tube light (±10%). The luminaire shall be suitable for Wall / conduit / suspended / surface mounting. .The certification , Specifications and warranty of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

10

725

7250

... More
For Sinage

-

-

-

... More
SITC of 20 pair krone with MS Box and With Frame

60

4381

262860

... More
SITC of Emergency Sport Light With Exit

35

11880

415800

... More
SITC of UV printing Base Double Side Exit Signage With Sheet Size 135mmX290mm.

35

7424

259840

... More
PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE:

-

-

-

... More
Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 0.5sq.mm (16/0.20mm), 2Core

6000

26

156120

-

-

-

... More
Supply and erection of AC Celling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body 3Nos of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos, of speeds. The product should have a manufcaturer's guarantee warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm comploto in all respects as per satisfcation of the Engineer In-charge at site.

268

3520

943360

... More
Supply and erection of Heavy duty Exhaust P 300mm, 900RPM Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer ilfe including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at sile.

5

4491

22455

... More
Supply and erection of Wall Fan Plastic Body 400MM, 16" Including flexible wire & petty material etc. for connections and tesl complete in all respect as approved and desired by the Engineer in-charges at site.

5

3353

16765

... More
EXTERNAL/FAÇADE LIGHTING

-

-

-

... More
FACADE LIGHTING

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor 0.9 . Fixture shall be suitable to operate at an ambient temperature range of - 10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.

-

-

-

... More
250 W with driver

2

4289

8578

... More
75 W with driver

2

2440

4880

... More
Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.

-

-

-

... More
70 W with driver

2

5916

11832

... More
40 W with driver

2

5177

10354

... More
Supplying, Installation, Testing and commissioning of surface mounted 50 W flood light new generation, energy saving, environmental friendly, long life aesthetically designed made of aluminium with white powder coating. The fixture shall be complete with driver and capable of operating at line voltage without any separate power supply from 110 to 275 V AC, 50-60 Hz, power factor 0.9. The Fixture shall be suitable to operate at ambient temperature range of -25°C to +45°C and shall be IP 67 and IK06 rated. The Lifetime shall be at least 50000 burning hours at 50°C and the luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with suitable mounting box,

10

4141

41410

... More
Supplying, Installation, Testing and commissioning of surface mounted 12W/Mtr. having 1200 lumen, new generation, energy saving, environmental friendly, long life aesthetically designed made of extruded aluminium channel single CCT neon flexiable strip, 12V DC, 12W/Mtr width-10mm. The strip shall be complete with driver and capable of operating at line voltage without any separate power supply from 110 to 275 V AC, 50-60 Hz, power factor 0.9. The Fixture shall be suitable to operate at ambient temperature range of -25°C to +45°C and shall be IP 65 and IK06 rated. The Lifetime shall be at least 50000 burning hours at 50°C and the luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with suitable mounting box.

10

12424

124240

... More
Supplying, Installation, Testing and commissioning of new generation, energy saving, environmental friendly, long life aesthetically designed made of aluminium 12 W, bollard luminaire for diffuse lighting with high power led as light source, The fixture shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 275 V AC, 50-60 Hz, power factor 0.85. The Fixture shall be suitable to operate at ambient temperature range of 0°C to +45°C and shall be IP 67 and IK06 rated. The Lifetime shall be at least 50000 burning hours at 50°C and the luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with suitable mounting box.

10

7247

72470

... More
Supplying, Installation, Testing and commissioning of new generation, energy saving, environmental friendly, long life aesthetically designed made of aluminium 10 W, 550 lumens ground burrial luminaire with high power led as light source, The fixture shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 275 V AC, 50-60 Hz, power factor 0.85. The Fixture shall be suitable to operate at ambient temperature range of 0°C to +45°C and shall be IP 67 and IK06 rated. The Lifetime shall be at least 50000 burning hours at 50°C and the luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with suitable mounting box.

10

3520

35200

... More
Supplying, Installation, Testing and commissioning of new generation, energy saving, environmental friendly, long life aesthetically designed made of aluminium 10 W, LED marker luminaire for diffuse lighting with high power led as light source, The fixture shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 275 V AC, 50-60 Hz, power factor 0.9. The Fixture shall be suitable to operate at ambient temperature range of 0°C to +45°C and shall be IP 67 and IK06 rated. The Lifetime shall be at least 50000 burning hours at 50°C and the luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.

10

3845

38450

... More
Supplying, Installation, Testing and commissioning of new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape 10 W Garden Spike, 550 lm, 4000K luminaire. The fixture shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 275 V AC, 50-60 Hz, power factor 0.85. The fixture shall be suitable to operate at ambient temperature range of 0°C to +45°C and shall be IP 65 and IK06 rated. The Lifetime shall be at least 50000 burning hours at 50°C and the luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with suitable mounting box.

10

2485

24850

... More
Supplying, Installation, Testing and commissioning of new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape 10W, 500lm, LED STEP LIGHT luminaire with suitable mounting box.

5

4141

20705

... More
GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR:

-

-

-

... More
Supply and erection of Galvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length (Raw material confiming to IS-5986 (FE-510), BSEN-10025S- 355J or ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conforming to IS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461- 1991 OR ASTM-A123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level as required:-

-

-

-

... More
Galvanized Octagonal Pole Overall Length 9 metre (Sheet thickness 3mm), Top dia.(A/F) 70mm and bottom dia. (A/F) 155mm, Foundation size below G/L 600mm x 600mm x 1700mm, 4Nos. Foundation Bolts size 24mm dia., Length≥750mm with Base Plate Dimensions 260mm x 260mm x 16mm Thick.

8

33616

268935.76

... More
Galvanized Octagonal Pole Overall Length 6 metre (Sheet thickness 3mm), Top dia.(A/F) 70mm and bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 1200mm, 4Nos. Foundation Bolts size 20mm dia., Length≥600mm with Base Plate Dimensions 220mm x 220mm x 12mm Thick

16

21228

339648.48

... More
GALVANIZED OCTAGONAL POLE BRACKETS:

-

-

-

... More
SINGLE/ DOUBLE ARM BRACKETS:

-

-

-

... More
Supply and erection of bracket for galvanized octagonal pole, the bracket should be fixed on the top of the pole having top outer dia. 70mm to 90mm (A/F) complete in all respect as approved by the Engineer-in-charge at site:-

-

-

-

... More
Double arm bracket 1.5 metre long for galvanized octagonal pole

16

3158

50530.88

... More
Single arm bracket 1.5 metre long for galvanized octagonal pole

8

2825

22603.04

... More
SITC 90 w street light .The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

31

8153

252743

... More
SITC 70 w street light .The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

8

6094

48752

... More
High Mast

-

-

-

... More
Supply , Erection Testing Commissioning of 30MTR High Mast With Special Latching arrangement in 3 Section Suitable for Max.wind speed 50 m/s . With Head Frame, Luminaries Carriage Suitable to install upto 16 Nos. Luminaries in Symmterical arrangement. Foundation Bolts Manufactured with special steel m30 X 850mm EN-8/TS600 Grade With 12 Nos. Nuts and Washers RCC/PCC Foundation as per manufacturer drawing complete with all respect including excavation and refilling of pit. The Foundation including Raft/Pedestal with Steel bars and RMC Concrete of M 25 Grade etc complete in all respects as approved and desired by the Engineer in-charge at sitee Erection of High Mast including all T & P complete in all respect. The Specifications and complaince as per approved spees of TA advisor to Hon'ble CM Punjab .

-

-

-

... More
Max.wind speed 50 m/s as per IS : 875 (Part - III) HIGH MAST SHAFT:- Height of mast (M)30 Meter Three ,No. of sections (Nos.)Three ,Material construction S 355 grade as per BS-EN10 025 610 mm, Bottom A/F (MM)610mm , Top A/F (MM)200mm, Plate thickness (MM)Top-Middle-Bottom 4-4-5, Section length (MM)10500-10500-10500, Cross section of Mast (Nos.)20 side polygon.Standard for of galvanizationAs per BS EN ISO 1461 1200 x 300 mm,Size of opening and door at base (MM)1200 x 300 mm,Diameter of base plate (MM)840 mm,Thickness of base plate (MM)36 mm,Lightning protection finialG.I single spike of length 1200 mm. LANTERN CARRIAGE:- Material of construction50 NB ERW Class B - M. S. Pipe 50 NB ERW Class B - M. S. Pipe ,Diameter of carriage ring (MM)711 mm (ID) 711 mm (ID) , Construction 8 Arm, Welded, 2 sections 8 Arm, Welded, 2 sections, Load carrying capacityUp to 16 Luminaire Symmetrical Up to 16 Luminaire Symmetrical. TRAILING CABLE :- Conductor Copper, 5 core, 2.5 sq mm,Insulation EPR insulated PCP scheathed , No. of circuits per mast One. WINCH / POWER TOOL :- Type Single Gear Double drum (SGDD),SWL of winch (KGS.) SWL 750 kgs, Method of operation Integral Motor,Motor capacity 2 HP,No of speeds 6 Pole, Single speed,Torque limitor With mechanical tripping facility. STAINLESS STEEL WIRE ROPE:- Grade AISI 316,Construction 7/19 construction,Number of ropes 2 wire rope system,Diameter (MM) 6 mm,Braking load capacity 2350 kg x 2 . FOUNDATION BOLTS :- Number of foundation bolts 12 nos. ,PCD of foundation bolts (MM) 740 mm, Type TS 600, Diameter 30 mm dia. ,Length of foundation bolts 850 mm long.

2

1087571

2175142

... More
SITC of 500 w flood light .The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt. of Punjab vide Letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Light fixtures manufactures should have in house NABL accredited laboratory.

16

44331

709296

... More
EARTHING

-

-

-

... More
Earthing with G.I. wire/rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).

-

-

-

... More
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length)

6

3315

19895.34

... More
Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length)

12

3687

44247

... More
Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length)

32

3770

120646.72

... More
Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-

-

-

-

... More
GI Earth rod 20 mm dia., 4.5 mtr. Long

4

1800

7200.68

... More
Bonding to existing earth with G.I. wire/ rope in heavy gauge (1.6mm thick) welded conduit pipe (On Surface) with bends, junction boxes, MS saddle clamps including painting etc.

-

-

-

... More
Bonding with G.I. wire 8S.W.G. (4mm dia) in HGW conduit pipe 20mm dia. (on surface)

10

101

1014

... More
Bonding to existing earth with G.I. wire/ rope in heavy gauge (1.6mm thick) welded conduit pipe (Flushed in wall) with bends, junction boxes and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Bonding with G.I. wire 8S.W.G. (4mm dia) in HGW conduit pipe 20mm dia. (Flushed).

10

143

1435.4

... More
Bonding to existing earth with 8S.W.G. (4mm dia) G.I. wire fixed with stapples on wall.

10

15

158

... More
G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH):

-

-

-

... More
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc.

-

-

-

... More
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface)

10

184

1843.6

... More
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed)

10

222

2227.1

... More
COPPER EARTHING:

-

-

-

... More
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-

-

-

-

... More
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long

2

8471

16943.66

... More
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long

10

11144

111443.4

... More
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 19.50 metre (63.96 feet) below ground level (up to 23metre in Length) with G.I. pipe 20mm dia. (A-class), 18metre long

42

15151

636369.3

... More
COPPER EARTHING (Upto 23 metre in Length):

-

-

-

... More
Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 19.50 metre (63.96 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 23metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 18metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation:-

-

-

-

... More
Earthing with 20mm x 3mm Copper Tape (upto 23Metre in Length)

1

26061

26061.48

... More
Earthing with 20mm x 3mm Copper Tape (upto 23Metre in Length)

1

28787

28787.1

... More
Earthing with 30mm x 3mm Copper Tape (upto 23Metre in Length)

2

31511

63022.48

... More
Earthing with 25mm x 5mm Copper Tape (upto 23Metre in Length)

1

37996

37996.37

... More
Earthing with 40mm x 5mm Copper Tape (upto 23Metre in Length)

2

51617

103234.16

... More
BONDING TO EARTH WITH COPPER WIRE:

-

-

-

... More
Bonding to existing earth with copper wire in heavy gauge (1.6mm thick) welded conduit pipe with bends, junction boxes, steel hooks and MS saddle clamps including painting etc.:-

-

-

-

... More
Bonding with copper wire 8S.W.G. (4mm dia) in HGW conduit pipe 20mm dia. (on surface)

20

206

4129.8

... More
Bonding with copper wire 8S.W.G. (4mm dia) in HGW conduit pipe 20mm dia. (Flushed)

20

231

4631.2

... More
Bonding to existing earth with 8S.W.G. (4mm dia) copper wire behind casing or fixed with stapples on wall.

20

110

2212.4

... More
COPPER EARTHING STRIP (As Additional Length):

-

-

-

... More
Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-

-

-

-

... More
Additional Length 25mm x 5mm thick Copper Tape

20

1039

20796

... More
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-

-

-

-

... More
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)

5

325

1629.75

... More
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)

5

343

1718.25

... More
Supply & erection of G.I. pipe (A-Class) as per IS:1239 (Part-I) 2004 including sockets, bends, inspection boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-

-

-

-

... More
Galvanized Iron Pipe 15mm dia. (A-class) On surface

5

169

848.05

... More
Galvanized Iron Pipe 15mm dia. (A-class) Flushed

5

187

936.55

... More
Galvanized Iron Pipe 40mm dia. (A-class) On surface

15

445

6681.3

... More
Galvanized Iron Pipe 40mm dia. (A-class) Flushed

15

458

6880.35

... More
CCTV SURVEILLANCE SYSTEM

-

-

-

... More
SITC of Camera shall utilize high sensitivity 5-Megapixel CMOS sensors with 1/2.7 Sensor”, 5MP Progressive Scan CMOS Sensor and Active Pixel count Effective Pixels 2880(H)x1620(V). Minimum Illumination 0.004Lux @(F1.6, AGC ON); 0 Lux with IR. Camera shall integrate automatic shutter, shutter time is (1/5s-1/20,000s Adjustable). Camera shall integrate 2.8-12mm Lens, F No. 1.8 (W) ~ 3.3(T), with Angle of View: Horizontal: 107-34°, Vertical: 55-19°, Diagonal: 134-38°. Camera shall have IRIS Control: Fixed/Auto. Camera shall integrate IR cut filter with auto switch (Day/Night/Auto/Image/Schedule). IR distance shall be up to 30m. Camera shall have Output PAL/NTSC adjustable. Camera shall offer WDR up to 120dB, (Off/On, WDR coefficient range). Camera shall support to adjust Image Setting Brightness, Contrast, Sharpness, Saturation, Color and 3D DNR noise reduction. Camera shall offer BLC/HLC modes of backlight compensation. Camera shall support to Automatic Gain Control, Automatic White Balance, Anti-Flicker, Mirror & Corridor mode. Camera shall have Digital Zoom feature. Smart Event. Camera shall offer intelligent analysis functions, Perimeter Intrusion Detection, Line crossing Detection, Human & Vehicle Detection, Stationary Object Detection, Cross Counting, Crowd Density detection, Queue Length, Rare Sound detection, Heat MAP, Face Detection. Camera shall support Motion Detection Support (8 level). Camera shall offer event Trigger Schedule Linkage: Capture, email, FTP upload. Audio & Video Encoding. Camera shall offer H.264 and H.265 Encoding image compression format. Camera shall offer the following resolution streams: Mainstream@30fps 5MP (2880x1620), 4MP (2560x1440), 3MP (2304x1296),1080P(1920x1080), 720P(1280x720), Substream@30fps 720P (1280x720), VGA (640x480), QVGA (320x240), Third stream@30fps VGA (640x480), QVGA (320x240). Camera shall offer CBR/VBR bit rate control, bit rate is between 256kbps-8Mbps suitable for different image quality and fluency requirements. Network Function. Camera shall support the following protocols: TCP/IP, HTTP, DHCP, DNS, DDNS, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS, FTP. Camera shall conform to the ONVIF Profile S, G, T. Camera shall have IRIS Control: Fixed/Auto. Camera approved makes bosch, mountxross, axis, pelco shall offer Up to 4 area privacy mask. Camera shall support setting Character Overlay (OSD) Title, time and date overlay. Camera shall support setting Unicast and Multicast Streaming. Camera shall support General Function like User Authentication, IP address filtering, Complicated password. Camera shall offer Built In web server with an interactive Graphical User Interface. Camera shall support UPnP, ONVIF Discovery Interface. Interface. Camera shall integrate 1*RJ45 10M/100M Ethernet Port. Camera shall support Audio port: 1 input (RCA), 1 output (RCA) & Alarm port: 1 input, 1 output. Camera shall support standard 256G Micro SD card storage. General. Camera shall have Power Supply PoE(802.3af)/DC 12V±10% with Power Consumption 5.5W (IR ON), 3W (IR OFF). Camera shall offer IP67 Weather resistant Protection Complaint with Metal Body. Operating Conditions shall be -35°C ~ 60°C Humidity 95% or less (non-condensing). Camera shall integrate 1 reset button. Makes : Bosch, Mobitech, Mountxross, Axis, Pelco

53

37050

1963650

... More
SITC of AI Network 60fps outdoor Camera shall utilize high sensitivity 2-Megapixel CMOS sensors with 1/2.8”, optical format, progressive scan and Active Pixel Count: 1920x1080 pixel array. Minimum Illumination Color 0.002lux @ F1.6(AGC ON) ; B/W 0 lux @ IR ON . Camera shall integrate automatic shutter, shutter time is 1/5 ~ 1/20000s Adjustable. Camera shall integrate 2.8mm - 12mm lens, Max. Aperture Ratio 1.8 (W) ~ 3.3(T), Lens Type Motorized(Ø14), Angle of View: 101 ~ 33°, Vertical:52 ~ 18°, Diagonal: 124 ~ 37°. Camera shall integrate IRIS Control: Fixed/Auto. Camera shall integrate IR filter that can automatically switch. (Day/Night/Auto/Image/Schedule). IR distance shall be up to 50m. Camera shall offer 120dB, which support three levels of Auto/Low/High. Camera shall support to adjust image saturation, brightness, contrast, sharpness, and 3D DNR noise reduction. Camera shall offer BLC, AGC, and WDR modes of backlight compensation. Camera shall integrate Anti-Flicker: Outdoor, 50Hz, 60Hz . Camera shall offer corridor mode, including rotation, suitable for corridor scenes, convenient for construction and installation. Camera shall offer 16x digital zoom. Smart Event . Camera shall offer intelligent analysis functions, including Face Detection, Human & Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Cross Counting, Stationary Object Detection, Heat Map, Crowd Density Detection, Queue Length Detection, License Plate Detection, and Rare Sound Detection. Audio & Video Encoding . Camera shall offer Video Encode H.265/H.264 compression format. Camera shall offer the following resolution streams : . Main stream@60fps - 1080P(1920x1080),960P(1280x960),720P(1280x720) . Sub stream@30fps - 720P(1280x720),VGA(640x480),QVGA(320x240). Third stream@30fps - VGA(640x480), QVGA(320x240) . Camera shall offer CBR/VBR bit rate control; bit rate is between 256 Kbps to 8 Mbps, suitable for different image quality and fluency requirements. Camera shall capable of Audio record with Built-in-mic. Network Function . Camera shall support the following protocols: TCP/IP, HTTP, DHCP, DNS, DDNS, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS, FTP . Camera shall integrate IR filter that can automatically switch. (Day/Night/Auto/Image/Schedule. approved camera makes bosch, mountxross, axis, pelco shall support setting a custom password to improve the security when logging in for the first time; User Access 2 (admin+user). Camera shall offer Up to Off/On (4 Zone, Rectangle) privacy masking. Camera shall support setting OSD, Self-adaptive with video background, date and time with different formatting. Camera shall offer Streaming Method : Unicast and Multicast . Camera shall offer IP address filtering. Camera shall have interactive Graphical User Interface, Web Server: Built In web server. Shall compatible with web browsers IE10/11, Safari V12.1 above, Firefox V.52 above, Google chrome V.57 above, Edge V.79 above . Camera shall support Discovery Interface UPnP, ONVIF . Interface . Camera shall integrate 1*RJ45 10M/100M Ethernet Port. Camera shall support standard 256G Micro SD card storage. General . Power over Ethernet (PoE): PoE IEEE802.3af / 12V DC Optional. The power consumption shall be 3W-4W max without IR on, and 5W - 7W max with IR on . Camera shall offer IP67-rated for Weather-resistant Performance. Camera shall offer Metal Housing . Operating Conditions shall be -35 °C ~ 60 °C Humidity 95% or less (non-condensing). Certifications & Standards. Camera shall have the following Certifications: CE, FCC, BIS.

25

40020

1000500

... More
Supply, installation, testing & commissioning of IP PTZ Camera1/2.9 "SONY Low Illumination 2.1MP CMOS Sensor,• H.264 Compression Method , 22X Optical Zoom (f=3.9mm-85.5mm),• IR Distance 120m Max., IP66 Outdoor,Horizontal Rotation Speed 60°/S,Horizontal Rotation Range 0°~360°,Tilt Rotation Speed 45°/s,Tilt Rotation Range 0°~90°,Auto FlipSupport,360° ScanSupport,A-B ScanSupport,Preset Points 220,Guard Tours3 groups,Guard PointsMax.16 points,Auto Control IR LED,Network protocolTCP/IP , TTP , NTP , IGMP , DHCP , UDP , SMTP , RTP , RTSP , ARP , DDNS , DNS , PPPoE , P2P,Network interfaceBuilt-in RJ45 network interface,support 10M/100M IP DATA,Operating Temperature Indoor: -40°~ +60°, Lightning ProtectionTransient voltage 6000V,Weight10.2Kgs

4

245020

980080

... More
SITC of 64 CH NVR shall have 64-channel video input. NVR shall be Embedded Linux. NVR shall support following bandwidth - 1280Mbps, Incoming 640Mbps & Outgoing 640Mbps. NVR shall support Video Output: 3 (1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080, 1600*1200, 1920*1200, 3840*2160/7680*4320) HDMI; 1 (1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080). Async out. NVR shall offer the following recording resolution streams Video Resolution: 12MP, 8MP, 5MP, 3MP, 2MP (1080P), 1.3MP (960P), 1.0MP (720P). NVR shall support Preview Capability: multiple matrix mode, Supported frame rate: 4K:240fps, 4MP:480fps, 2MP:960fps. NVR shall support schedule base snapshot, manual snapshot, event-based snapshot. NVR shall support Motion Detection. NVR shall support 4 zones Privacy Mask. NVR shall offer intelligent analysis functions powered including Human & Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Stationary Object Detection, Crossing Counting, Heat Map, Crowd Density Detection, Rare Sound detection (gunshot/baby crying/dog barking), Face Detection. AUDIO. NVR shall support G.711A/G.711U Audio compression. NVR shall integrate Audio input 1 CH RCA port. NVR shall integrate Audio output 1 CH RCA port, HDMI audio. Video Recording and Playback. NVR shall support 1-30fps Video Frame Rate. NVR shall have Record Mode: schedule, event based- motion, I/O, PIR. NVR shall offer 16 CH max sync playback. NVR shall be able to playback according to different types, including Playback Mode Instant playback, Local video, local image. NVR shall support Record Search Time, calendar, channel search, and event search, (ANR, regular video, motion detection video, alarm video, intelligent detection video). NVR shall support following Video Playback: Start, stop, normal play, back play, frame by frame forward, full screen, Fast forward/backward (2x, 4x, 8x, 16x), Slow forward (1/2x, 1/4x, 1/8x, 1/16x), Add custom/ Default Tag, digital zoom, video clip, sub-stream/main-stream, playback video bar, scale of 30 mins to 24 hrs. NVR shall support 8 SATA, 1 x eSATA, HDD Capacity Single max. 18TB (enterprise class) & up to 12TB Surveillance HDD. NVR shall support RAID0, RAID1, RAID5, RAID6, RAID10. NVR Should have S.M.A.R.T info feature to check health of HDD, temperature and status. NVR shall offer Local, Network HDD NFS, SMB/CIFS. NVR shall offer USB mobile hard disk, U disk, network backup Method. NVR Should support FTP for uploading alarm video. NVR shall ANR Support Smart IPC (with SD card) ANR. Function. NVR shall support the following protocol: IPv4, IPv6, TCP/IP, HTTP, HTTPS, DDNS, RTMP, SMTP(SSL), SNMP, DHCP, PPPoE, UPnP, NTP, P2P, FTP, IP filter. NVR shall support ONVIF Profile S Support. NVR shall support ONVIF/RTSP/HTTP/HTTPS/RTMP port customized. NVR shall support Mobile Surveillance Support Apple, Android & Internet Explorer Support IE, Chrome, Firefox, Safari. NVR shall Digital Zoom support. NVR shall have IPC timing Manual/auto/timing/reconnect timing. NVR shall support the following Event Actions: pre and post recording, Send email, show message, send email, FTP upload video or screenshot, Cloud upload video or screenshot, full screen, voice prompts, Alarm output trigger, PTZ linkage. NVR Should support combination of different events for effective alarm trigger and response. NVR Shall have exception alarms on event type of no space on disk, disk error, video loss. NVR makes bosch, mountxross, axis, pelco Shall be able to configure covert on camera by which recording is happening, but live view is restricted. Network Detection monitoring, Utilization of total and used bandwidth, IP filter with blacklist and whitelist. NVR Shall support video cover privacy mask both on live and recording up to 4 areas. NVR shall have User Management User add,

2

252318

504636

... More
SITC of L2+ Managed Industrial Grade POE Switch 10 Ports Gigabit Managed Industrial Grade POE Switch , 8 10/100/1000 Base- TX portand 2 Gigabit SFP slotand 1console port Network Protocols: Support , IEEE802.3, IEEE802.3u, IEEE802.3z , IEEE802.3ab , IEEE802.3x , IEEE802.1d , IEEE802.1w , support IP camera should Working temperature:-40~75℃ Storage temperature:-40~85℃, Relative Humidity : 5%~95% (no condensation), Shell : IP30 protectgrade, metal shell Installation : DIN- Railor Wallmounts, MTBF : 300,000 hours , Support L2+ Switching features including 802.1Q VLAN, Mirroring, Portisolation, IGMP Snooping, DHCP Snooping, LLDP, IP Source Guard, ARP inspection, ACL setc. Support spanning tree STP(802.1D) and RSTP (802.1W) .802.1s (MSTP) way exchange time 50ms Jumbo frames support upto 9.6 Kkilobytes Support enhanced managemen through WEB,CLI, TELNET, SSH, SNMP Ethernet port support 10/100/1000 Mself-adaption.Bandwidth: 24Gbps, Packet Buffer Memory: 4M Packet Forwarding Rate:1488000 pps /port Address Table : 8K.

3

72318

216954

... More
Supply, Installation and Comissioning of Technical Specifications, 24-port 10/100/1000 Base-T Gigabit PoE Managed Switch, Physical Specifications, 24 # 10/100/1000 Base-T auto-sensing PoE+ ports, 2 dedicated 100/1000 Base-X Fiber SFP ports, Performance Specification, Bandwidth: 52 Gbps non-blocking, Heat Dissipation (worst case, all ports used, full PoE, line-rate traffic) (BTU/hr): 780.20 BTU/hr, Weighted Round Robin (WRR) and Strict Priority, MAC Address database size: 8,000 media access control (MAC) addresses, VLAN: 256, 128 Multicast groups, Number of DHCP snooping bindings: 256, Access Control Lists (ACLs): 100 shared for MAC, IP and UDP/TCP ACLs (ingress), Packet forwarding rate (64 byte packet size) (Mpps) : 38.68, Jumbo frame support: Up to 9K packet size, Packet buffer memory (Dynamically shared across only used ports): 0.5 MB, 1G Copper Latency(64-byte; 1518-byte; 9216-byte frames): 3.749μs ; 4.675μs ; 3.762μs, Max power (worst case, all ports used, full PoE, line-rate traffic) (Watts): 228.53 W, Auto Power Down, PoE budget: 190W, PoE Timer should be configurable on ports, PoE Power allocation on per port. , Minimum 500 Mhz MIPS-4KEc CPU, 128MB RAM, 32MB SPI FLASH or higher, IEEE Network Protocols, IEEE 802.1Q VLAN Tagging, IEEE 802.3at PoE+, IEEE 802.3az Energy Efficient Ethernet (EEE), IEEE 802.3ad Trunking (LACP), IEEE 802.1s Multiple Spanning Tree (MSTP), RSTP , IEEE 802.1X Radius network access control, Network Security and Traffic, Guest VLAN, Mulit-site, multi-network should be manageble under single console, RADIUS accounting, Network Storm Protection, DoS attacks prevention, Broadcast, Unicast, Multicast Protection, Access Control Lists (ACLs) L2 / L3 / L4, IP-based ACLs (IPv4 and IPv6), MAC-based ACL, TCP/UDP-based ACL, Centralized network configuration (policies), MAC lockdown by the number of MACs, IEEE 802.1x Radius Port Access Authentication, Control MAC # Dynamic learned entries: 600, Control MAC # Static entries :20, IEEE 802.1Q VLAN Tagging, IEEE 802.3ad - LAGs - LACP ( (8 LAGS with max. of 8 members in each LAG)), Broadcast Storm Control, IGMP Snooping (v1, v2 and v3) IGMP Snooping queriers, Quality of Service (QoS), Port-based rate limiting, Port-based QoS, DiffServ QoS, IEEE 802.1p COS, IPv4 DSCP, Diff Serv QoS, IPv4 ToS, Management, Password management, aallied telesis should have configurable Management VLAN, Admin access control via Radius and TACACS+, Web-based graphical user interface (GUI), Smart Control Center (SCC) for multiswitch management, Remote cloud based management. , IPv6 management, Configurable in-app and email alerts and notifications, Dual Configuration file, SSL/HTTPS and TLS v1.0 for web-based access, TFTP/HTTP File transfers (uploads, downloads), HTTP Download (firmware), Syslog (RFC 3164), LEDs, Per port: Speed, Link, Activity, Per device: Power, Fan and PoE Power Status, Environmental Conditions, Operating Temperature: 32° to 122°F (0° to 50°C), Operating Humidity: 90% maximum relative humidity, non-condensing, Storage Temperature: – 4° to 158°F (–20° to 70°C), Storage Humidity: 95% maximum relative humidity, non-condensing, Operating Altitude : 10,000ft (3,000m) maximum, Certifications, CE mark, commercial, UL listed (UL 1950)/cUL IEC 950/EN 60950, 47 CFR FCC Part 15, SubpartB, Class A, ICES-003: 2016 Issue 6, Class A, ANSI C63.4:2014, IEC 60950-1:2005 (ed.2)+A1:2009+A2:2013, AN/NZS CISPR 22:2009+A1:2010 CLASS A, Safety , AN/NZS 60950.1:2015, IEC 60950-1:2005 (ed.2)+A1:2009+A2:2013, EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013, CSA certified (CSA 22.2 #950), CCC (China Compulsory Certificate), Warranty and Support, Lifetime hardware replacement warranty, Lifetime free latest firmware support, Replacement with New

6

80559

483354

... More
SITC of Layer 3 Core Switch Switch should 1RU with 24* 10GE SFP+ ports & 4*100GE QSFP28 ports Layer 3 10GbE Managed Switch with fuly populated with Required SFP+/QSFP28 Module and Two AC hot-swappable power modules. Should have RJ-45 console ports. 1 x 10/100/1000BASE-T RJ-45 Ethernet for out-of-band IP management. 1 x USB. Switch should be stackable up to 4 Switches. Switch should be IPv6 ready. Switch shall have hot swappable modules. Switching Capacity should be 1.280 Tbps & Packet Forwarding rate should be 952 Mpps. MAC Address Table should be Up to 32K entries or More. Packet Buffer Memory 4 MB. Should have IEEE Standards of Ethernet: IEEE 802.1D, 802.1s, 802.1w, 802.1x, 802.3ad, 802.3x, 802.1p, 802.1Q, 802.3u, 802.3ab, 802.3z. Switch should support Port isolation, Port security, and “IP+MAC+port” binding, DHCP Snooping, IP source guard, IEEE 802.1x, Radius and Tacacs+, DDoS, TCP’s SYN Flood, UDP Flood, etc, Broadcast/multicast/unknown unicast storm-control, Supports encryption MD5, etc. Switch Should Support Flow Control, Spanning Tree Protocol, 802.1D STP, 802.1w RSTP, 802.1s MSTP, Root Guard, Loop Guard, Jumbo Frame. Switch Should Support 802.1AX Link Aggregation, 8 groups per device, 8 ports per group, ERPS (Ethernet Ring Protection Switching). Switch Should Support Port mirroring Supports one-to-one, many-to-one, Supports mirroring for Tx/Rx/both, Supports 4 mirroring groups, VLAN mirroring, L2 protocol tunneling, Loopback Detection (LBD). Should support Static Route, Default Route, OSPF for IPv4 and IPv6, RIPv1/v2, RIPng, and Policy-based Route (PBR) for IPv4 and IPv6, support for BGPv4, VRRPv3, IPv6 Neighbor Discovery (ND). Should suppoort Static, ISATAP and 6to4 IPv6 Tunneling. Should support IGMPv1/v2/v3 for Layer 3 Multicast, L3 multicasting features such as IGMP, MLD, PIM-DM, SM. Should support 802.1p Quality of Service with 8 queues per port. Should support Queue Handling with Strict Priority Queue, Weighted Round Robin, Deficit Round Robin (DRR), SPQ + WRR and WFQ. Should support QoS based on 802.1p Priority Queues, MAC address, IP address, DSCP, VLAN, TCP/UDP port, Switch port. Should support Ingress and Egress ACL, Time-based ACL. Should support Access Control List based on 802.1p priority, MAC address, VLAN, TCP/UDP port number, DSCP, IP addres. Should support 802.3ah Ethernet link OAM and 802.1ag Connectivity Fault Management (CFM) and Y.1731 OAM. Shall have Ethernet management port for GUI and console management for CLI support, Switch should support AAA using RADIUS/TACACS+, Switch shall have SSHv2, SNMPv2c, SNMPv3 and NTPv3/NTPv4. AC Voltage: 100 to 240 V AC, 50Hz ± 10%, Operating Temperature - 0 to 50 °C. OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. OEM should have Indian based operation at least for a period of 20+ years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years.  (To ensure only principal networking companies participate having strong Product , Support and Service.)

1

876130

876130

... More
Supply, Installation, Testing & commissioning of HDD Formatted capacity 8 TB surveillance ,Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s,Cache (MB) 64,Rotational speed (RPM) IntelliPower ,Load/unload cycles4 300,000,Non-recoverable read errors per bits read 1 in 1014, Operating (2 ms, read/write) 30, Operating (2 ms, read)65, Non-operating (2 ms)250, Average power requirements (W) Read/Write 5.90,Idle 4.90,Standby and Sleep 0.40 complete in all respects.

9

44289

398601

... More
Supply Installation, Testing & commissioning of Display : 65 inch, 4K (3,840 x 2,160), Direct LED, Professional Display with 4K Processor, Native Contrast ratio 1,200:1 or higher, Response time 12 ms or lower, Brightness 400 cd/m² or higher, 24/7, Portrait/Tilt functionality, HDMI Auto wake up, HTML5 platform, 16GB On Board Storage, HDMI*4 with HDCP 2.3 / RS232 / USB / RJ45 / Wi-Fi Direct / 20W Speakers / Android OS or similar, Viewing angle 178 degree, Apple AirPlay & Chromecast

2

146269

292538

... More
Supply Installation, Testing, commissioning & Laying of Cat 6 Cable in existing conduit Category 6 Unshielded Twisted Pair 23 AWG:305mtr. ,4 pair 100W cable shall be compliant with ANSI/TIA/EIA-568-C.2 Additional Transmission Performance Specifications for 4-pair 100W Category 6Cabling. Tested upto 600 MHZ; Construction: 4 twisted pairs separated by internal X shaped, 4 channel, polymer spine / full separator. Half shall not be accepted.Sheath : FRPVC/LSZH,Outer Diameter 6.1 mm nominal;Temperature Range -20° to +60°C.Manufacturer should have ISO 9001:2008 Certification for Quality Management System.Manufacturer should have ISO 14001:2004 Certification for Environmental Management System.All UTP and Its Components should be from same OEM.

3500

86

301000

... More
Supply Installation, Testing & commissioning of 6 Mtr HDMI Cable for NVR, UL Listed

2

5197

10394

... More
Supply, Installation, Testing and Commissioning of Patch Panel should be made of cold rolled steel.Should conform to TIA / EIA 568-C.2 Component Compliant.Should terminate 24 UTP CAT 6 (4 pair) Cables.Should confirm to EIA/TIA 568A wiring Pattern.Each port Should be features the spring-loaded shutter.Should be prevents incomplete mating Should be protects from dust and contaminants.Should be Front and rear port labelling as well as panel identification label.Should be Integral cable management shelf ensures bend radius compliance.Operating Life should be minimum 750 insertion cycles.Should be RoHS compliant.

9

18562

167058

... More
Supply, Installation, Testing and Commissioning of Patch Cord 1 Mtr Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant.

170

294

49980

... More
Supply, Installation, Testing and Commissioning of Patch Cord 2 Mtr. Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant.

85

334

28390

... More
Supply, Installation, Testing and Commissioning of Cat-6 Information Outlet with Face Plate and Gang-box Face Plate. Category 6, EIA/TIA 568-C.2.Use insulation displacement connectors.All information outlets should be 22-24 AWG copper.Should have shutter on I/O to avoid dust.Should have Plastic Housing: Polycarbonate, UL94V-0 rated or equivalent.Contact Plating: 50 μinches gold over 100 μinches nickel.Operating Life: Minimum 20 Re-terminations.Single Gang square plate, 86mmx86mm.Write on labels in transparent plastic window – supplied with plate.Should be RoHS compliant.

85

1032

87720

... More
Supply, Installation, Testing and Comissioning of 42U Network Rack Enclosure Frame-600X800-STEEL with accessories like fan, pdu, cable manager etc. Supply, Installation, Testing and Comissioning of 42 U Enclosure Frame-800X1000-STEEL, Caster Wheels Set of 4 (2 with Brakes & 2 without Brakes), Adjustable Levellers set of 4, Glass Door-800-42U, Metal Door-800-42U-Vented, Side Panels-1000-27U-Vented, Mounting Hardware-(Pack of 20), FHU with 4 FAN 360CFM, Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug, Vertical Cable Manager-42U-Loop, Horz. Cable Manager-1U-Loop, Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility maximizing the usable mounting space, Depth adjustable mounting slots, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with pretreatment process meeting all industry standards, Grounding and Bonding Options can be provided, 100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment, Conforms to DIN 41494 or equivalent standard, Welded Frame, Lockable Toughened Glass Door, Metal Vented Door Steel, DIN Standard 10mm Sq. Slots / Direct M6 Tap, 19” Mounting angles made of formed steel Powder Coated, Welded to Frame, Vented and Field Cable entry exit cut outs.

1

84792

84792

... More
Supply, Installation, Testing and Comissioning of Outdoor Wall Mount 12U x 600 W x 600 D , Front Glass Door (tinted, Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC. as per DIN 41494 Standards.

3

33605

100815

... More
Supply, Installation, Testing and Comissioning of Indoor Wall Mount 12U x 600 W x 600 D , Front Glass Door (tinted, Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC. as per DIN 41494 Standards.

6

18755

112530

... More
Supply, Installation, Testing and Comissioning of O. F.Cable 06F Outdoor - Armoured Unitube SM - HDPE Sheath The fiber is optimized for operation at 1310 nm and at 1550 nm., The Fiber should be Armoured 6 core unitube 9/125 μm SM fiber with central loose tube jelly compound, Glass Yarns in between Steel Tape & Loose Tube., Armour Tape : Corrugated steel Tape Armoured, Jacket material : HDPE, Outer diameter : 9 ± 0.3 mm, Thickness of the Jacket: 1.8 + 0.2 mm, Pulling Tension: Short Term 2000N, Long term 1000N, Crush Load: 3000N/100mm, The Fiber Operating Temperature should be – 20 deg C to +60 deg C and, The Fiber Max Attenuation ± 0.36 (db / km) @ Operational Wavelength 1310 nm and, ± 0.22 (db / km) @ Operational Wavelength 1550 nm ., The Fiber - type should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675, The value for Mode-filed/Cladding Diameter (um) 9.2 ± 0.4 and 125 ± 0.7, The Dispersion value =3.5 =18 (ps/(nm-km) and PMD value =0.2 (ps/km) and Cable Cut-off wavelength =1260 (nm), The Fiber should follow Standards: ISO 11801, IEC 60793-1/60794-1-2 and ITU-T-REC G.652D, Testing methods are in accordance with the following standards: ITU-T G.652.D, IEC 793-1 and Telecordia : GR-20 Core,ISO : 11801.

1000

334

334000

... More
Supply, Installation, Testing and Comissioning of LIU 12 Port Rack Mount (SC ) SM. LIU accommodate Simplex SC Single mode adapters., Cold steel base material with powder coating. Aluminum top and front cover for light mounting, can manage both splices and terminations, Preassembled shelves in multiple configurations, should have fiber magic sticker provision inside for 900um tight buffered fiber storing, Accessory kit consists of cable ties, mounting ear screw and spiral wrap tube, cable saddle., Front-Mounted Cable Saddles for jumper management, Removable Top & Front cover for better access to interior of LIU , Rubber grommet allow for pre-terminated fiber trunk installation, protects cable and minimizes dust build-up, Adapter panel - Cold Steel, 1.5mm Thickness, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, Snap-in locker design, easy to change adapter panels for various connector patching.

7

14657

102599

... More
Supply, Installation, Testing and Comissioning of 24 port LIU accommodate Simplex SC Single mode adapters., Cold steel base material with powder coating. Aluminum top and front cover for light mounting, can manage both splices and terminations, Preassembled shelves in multiple configurations, should have fiber magic sticker provision inside for 900um tight buffered fiber storing, Accessory kit consists of cable ties, mounting ear screw and spiral wrap tube, cable saddle., Front-Mounted Cable Saddles for jumper management, Removable Top & Front cover for better access to interior of LIU , Rubber grommet allow for pre-terminated fiber trunk installation, protects cable and minimizes dust build-up, Adapter panel - Cold Steel, 1.5mm Thickness, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, Snap-in locker design, easy to change adapter panels for various connector patching.

4

18206

72824

... More
Supply, Installation, Testing and Comissioning of PIGTAIL SC SM SIMPLEX LENGTH- 1m Provide a field installable Single mode SC pigtails to terminate fiber optic cables from cable-to-cable, cable-to-equipment and equipment-to-equipment. , Utilize a UPC polishing on the tip to provide high yield during installation., Meet TIA/EIA 568.C.3 standards for repeatability. , Cable Color Yellow , Insertion Loss (Max) 0.3 db Max., Mating Cycle 1000 times, Return Loss /= 50 db for UPC, Connector ferrule Ceramic, Buffer diameter 900um Tight buffer, SC Type Simplex Type, Minimum bend Radius: Install :30mm, Retention Strength: 20N, Cable 900um Buffered, Operating Temp. -40 deg. C to + 85 deg. C.

108

520

56160

... More
Supply, Installation, Testing and Comissioning of PATCH CORD LC-SC SM DUPLEX LENGTH- 3m Optical fiber patch leads shall comprise of Simgle mode 9/125μm fiber with LC-SC fiber connectors terminated at each end. The optical fiber patch leads shall comply with the following specifications: Single mode G652D, Connector Should be Zirconia ceramic ferrule, Pre-radiuses and pre-polished ferrule, Duplex Type, Cable yellow Color, Insertion Loss 0.3 db , 9/125, Single Mode, Return Loss /= 50dB for UPC, Durability 200 mating cycle , Working Temperature -10 deg. C to + 70 deg. C, Length Should be 3 Meter.

30

3564

106920

... More
Supply, Installation, Testing and Comissioning of 10G SFP+ Transceiver for Single Mode Fiber Transceiver should be Enhanced Small Form-Pluggable (SFP+) form factor and compatible with quoted switches., Transceiver should be Hot pluggable and support 10G speed on Single Mode, Multi-Source Agreement (MSA) Compliant & ROHS Compliant., Transceiver should be ƒcompliant with IEEE802.3ae standards., Transceiver interface should be Duplex LC conne, Transceiver interface should be Duplex LC connector., Transceiver should support Single-mode 9/125 um fiber, Operating Temperature: 0 to 70 °C, Certification - FCC, CE, VCCI, LVD.

18

36642

659556

-

-

-

... More
Supply, unloading, installation, testing & commissiong of rack mounted modular server type 40 KVA x 4 nos. i.e. 160 KVA expandable upto 160 KVA in module of 40 KVA UPS complete with all required accessories, complete with rack, with IGBT based rectifier to achieve THDI 3% and input power factor of greater than 0.99. The system shall be True Online ,3 Phase input and 3 phase 415 V output, 125% rated Rectifier cum charger unit +100% rated Invertor, Integrated in UPS module 100% rated Inbuilt Maintenance By Pass, 100% rated moulded case battery circuit breaker having thermal,magnetic and Automatic U/V trip mechanics. Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments. Suitable nos. "SMF" maintenance free batteries completely suitable for providing 15 minutes backup on full load. Matching cabinet / open racks to house SMF batteries for given ratings UPS along with interconnecting links, MCCB etc. complete as required & as per specifications. flexible single core copper cable of an approved makes for making interconnections between UPS to UPS, UPS to batteries, UPS to Isolation Transformer, complete as required, including providing Battery circuit breakers as required.

-

-

-

... More
UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable in giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-based scripts.Event logging, data logging and action logging (with date, time, description of fault and event) and Local notification through audible alarm. The system shall be complete in all manners: (1 UPS For CCTV Camera's & 5 For Basement to Fourth Floor Emergency Lighting)

-

-

-

... More
40 KVA

2

1234321

2468642

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
Supply, erection, testing & commisioning of Early Streamer Emission (ESE) type Lightning Protection Complete with Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome body capable of working in hazardous atmosphere and protecting against direct Lightning point as well conducting /diverting it to earth completely after tracing the Lightning in advance. As per NF C 17-102:2011 the air terminal should be tested for Lightning impulse current (10/350 micro sec) =100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shall offer a protection radius of 79mtr., Level-1 High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast. (Its working principle evolves from local electrostatic field that develops naturally around the system as a thunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering device generates high tension pulses at the conductor tip, causing a 'corona effect'.)Protection radius of 79Mtr at level 1 & 107 Mtr at level 4.

5

87666

438330

... More
Supply and fixing of Gl Mast 5 mtr. height along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast. The Adapter shall have suitable Metal connector /Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conducto, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required.

5

8998

44990

... More
Supply and installation of Lightning Strike Counter (6 digit display) of non-resettable (electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system. This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures. It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs. above the ground level.

5

11853

59265

... More
Supply & erection of test Link of non-corroding, weather proof, water proof polycarbonate IP 65/55 enclosure including providing of 2 Nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire. The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor.

5

2915

14575

... More
Supply, installation & testing of chemical earthing (Maintenance Free Earthing) system with UL approved copper bonded rod and exothermically welded copper busbar both tested by CPRI at 50kA Fault Current. A copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper coating thickness of minimum 250 microns. Along with earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A copper clad steel solid ground wire of 8 mm dia. for interconnecting earth pits. Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber. The grounding minerals should not be pollute the ground water. The grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr.

15

11328

169920

... More
Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20, Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge.

20

2902

58049.6

... More
PVC INSULATED FR COPPER CONDUCTOR CABLES:

-

-

-

... More
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Make: Havells/ RR Kabel/ KEI/ Plaza/ Kunthkib/ Polycab/ L&T, Rellison, or Equivalent

-

-

-

... More
Overall size 70sq.mm (Un-sheathed)

2250

801

1802677.5

... More
FIRE DETECTION AND FIRE ALARM SYSTEM

-

-

-

... More
Supply of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event , 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature will offer Redundant CPU. Four access levels, flash EPROM, Panel should be capable to work 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall support with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus/ Bacnet over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. UL & FM Approved make notifier,xls 3000 ,bosch UL, johnson control ( IFC Series) nohmi shall be capable for remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM.

1

510529

510529

... More
Supply of Loop Cards supporting cable length Up to 12,500 feet (3,810 m) on a Class B (Style 4) SLC loop(twisted-unshielded), Maximum resistance: 50 ohms,Built-in degraded mode increases survivability,Very simple installation — plug-in style, Permits multiple loops in small enclosure. This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). UL & FM Approved

8

77842

622736

... More
Supply of Inbuilt automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH with Emergency evacuation Control Panel & Digital Voice command system with Battery Dress Panel. The solution should be from single OEM. The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM.. .

1

73871

73871

... More
Active Repeater Panel with minimum 600 Characters Liquid Crystal Display with backlit control. panels with integrated power supplies, main power supplies Power-limited RDP interface. Sends an acknowledge message to the panel. send a system silence command to the panel, with the particular silencing action information stored at the FACP. Verification screen appears on networked displays. send a system reset command to the panel, with the particular reset action information stored at theFACP Panel should Scroll/display a list of associated events. Panel should Security, trouble: Scroll/display a list of associated events. Panel should Soft keys are the six keys to the right and left of the display. Use them to select commands that appear on the display for each different screen. UL & FM approved

1

169947

169947

... More
Supply of Paging Microphone compatible with Emergency evacuation Control Panel Project specific OEM authorization required for executing agency.

1

37538

37538

... More
Supply of Addressable Smoke photo-Thermal Detector and base with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th EditionThe solution should be from single OEM. OEM should have manufacturing facility in India. The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM. UL & FM Approved

610

5627

3432470

... More
Supply, Installation, Testing & Commissioning of Reponse Indicator for up side of ceiling

193

1106

213458

... More
Supply of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab. UL & FM Approved

261

5058

1320138

... More
supply of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab. UL & FM Approved

62

6333

392646

... More
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Autoaligned Beam Detector. The beam detector shall be used for High Ceiling application with a detection range from 5 upto 100 mtrs and highly resistant to building movement; tolerates +/- 1° movement, Resistant to solid object intrusion, , Built-in imager heater, Resistant to strong light sources; does not alarm when saturated by sunlight, Automatic sensitivity threshold level settings and drift compensation. The detector shall be IP-55 compliant.

4

117778

471112

... More
Supply, Installation, Testing & Commissioning of Addressable Duct Smoke Detector. The duct detector shall have an air velocity rating from 100 to 4000 ft/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches.\

10

23370

233700

... More
Supply of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. UL & FM Approved

60

6137

368220

... More
Supply of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab.

50

7508

375400

... More
supply of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab. UL & FM Approved

20

6333

126660

... More
supply of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab. UL & FM Approved

67

5290

354430

... More
Supply of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab. UL & FM Approved

1

6587

6587

... More
Supply of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center. UL & FM Approved

1

15174

15174

... More
Supply of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center. Each Telephone jack should have separate address. UL & FM Approved

12

3933

47196

... More
Supply of Digital Audio Amplifier with cabinet & Amp power supply. Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of 100 W at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall (be Wall/Panel Mounted) not be rail mounted / dependant on Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of Amplifier operation. Approved make notifier,xls 3000 ,bosch UL, johnson control ( IFC Series) nohmi amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers shall provide back up of minimum 5 hours using secondary power source(battery power/UPS power). .The solution should be from single OEM. The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM. UL & FM Approved

3

240984

722952

... More
Supply of Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on the same peer-to-peer Network and 2 ways Communication capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. Products not having this feature must provide dedicated CPU for DVC. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. The panel shall be capable of self programming without any dependency on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for programming the panel with all necessary licence. Panel shall have Modbus/ Bacnet over IP protocol for future integration with BMS. However, for the present arrangement the FA system will be standalone with 24x7 monitoring. Approved make notifier,xls 3000 ,bosch UL, johnson control ( IFC Series) nohmi panel shall be capable of remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th Edition. The solution should be from single OEM. The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM. UL & FM Approved

1

377366

377366

... More
Supply of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed. Project specific OEM authorization required for executing agency.The solution should be from single OEM. The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM. UL & FM Approved

300

3767

1130100

... More
Supply, Installation, Testing & Commissionning of Back box for speaker as per site requirement

300

1654

496200

... More
supply of Providing & fixing of fire resistance cable(Colour Red) (at 950° C for 180 minutes) of BS6387/BS7846 Fire survival Cable for fire alarm & PA system, 2C X 1.5 sqmm, BS6387 & BS7846, annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanized steel wire armour, low smoke & zero halogen (LSZH) red outer sheath. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3), of

2000

315

630000

... More
Supply of Power points with wire, Switches and Moduler Box complete all accessories

77

1655

127435

... More
Supply of ExiLED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code, The solution should be from single OEM. OEM should have manufacturing facility in India. The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM.

15

18630

279450

... More
Supply of AgoraLED NM LED IP65 230V 2X6W 1h/3h/8h. The luminiare comes in plastic housing. Mounting bracket is not required for this luminaire, IP65/NA 0 Non -Maintained Self Testing 12V / 7Ah Pb, LED based for anti-panic area, surface assembly Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch High lumen output – 1h = 360lm / 3h = 170lm / 8h = 70lm Simple and quick assembly and maintenance Technical lifetime of LED 100 000 hours • IP65 – dust and waterproof luminaire, Voltage 220-240VAC / 50-60Hz Power consumption 11.4W / 11.8VA Battery 12V / 7Ah Pb Battery protection Over charge protection /deep discharge protection Charging Time 23 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source LED 2x6, Technical lifetime (light source) 100 000 hours, Lumen output, emergency (1h / 3h / 8h) 3200 / 1600 / 800 lm, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IP rating IP65, Dimensions 302 x 94 x 210 mm, Weight 4200 / 4420 gr, Materials PC/ABS, PC, Aluminium, Mounting method Wall mounting, The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab.

12

62285

747420

... More
Supply of Online UPS 1 kva 800 Watts Tower UPS with 1 hour battery backup. Operating Temperature Range 0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter, Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No's, Rated Input Voltage 208/220/230/240 Vac, Maximum working input voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity, Rated kVA 1000 VA, Rated kW 800 Watts, Load type Resistive load/ lagging load/ non-linear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio 3:1, Online Efficiency 88%, Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available, Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available, Intelligent Fans Speed control Available, Auto restart function Available, Cold start Available. Make Eaton, APC, GE

1

44291

44291

... More
Baggage Scanner ,Door frame metal detector & Boom barrier

-

-

-

... More
Baggage Scanner Channel size 500 (wide) x 300 (high) mm Conveyor belt speed --0.22 ±0.22m/s Max load of conveyor belt 130 kg Resolution diameter --0.0787mm metal wire Penetration 28mm steel plate Film safety ISO1600 film safety Through the national standard GB15208.1-2005 detection Through ISO9001 authentication Through ISO14001 environment authentication Through OSHA18001 professional health management system certification Safety certification through radiation Through software enterprise certification, through software product certification Through the national Ministry of public security and police electronic products quality testing center inspection New integration F-stat project, non- computer HDD system, chip integration, better stability and higher operation efficiency. The direction of the ray beam Upward Tube current --0.4~1.2mA(Adjustable) Tube voltage 80~110 kV(Adjustable)Cooling / working cycle oil cooling/100% X ray sensor L type photodiode detector Monitor High-Resolution, LCD Accord display 19 inches image display 24 bits deep of true color, image enhancement, edge enhancement, Super Image Enhancement, High Penetrate Strength, Display, Low Penetrate Strength Display, Image Magnifier, Brightening/Dimming, Image Recurrence, Image Restoration, Image Storage, Multi energy penetration the organic matter is orange, inorganic is blue, and the mixture is green. Working temperature / humidity 0℃~45℃/20%~95% (Not condensing) Storage temperature / humidity 20℃~60℃/20%~95% (Not condensing) working voltage 110VAC (±10%) 50±3Hz Noise 58DB.

1

1953032

1953032

... More
Baggage Scanner Channel size 600 (wide) x 400 (high) mm Conveyor belt speed --0.22 ±0.22m/s Max load of conveyor belt 130 kg Line resolution diameter --0.0787mm metal wire Line penetration force 28mm steel plate Film safety ISO1600 film safety X ray generator The direction of the ray beam Upward Tube current -- 0.4~1.2mA(Adjustable Tube voltage 80~110 kV(Adjustable Cooling / working cycle oil cooling/100% X ray sensor L type photodiode detector Monitor High- Resolution, LCD Accord display 19 inches image display 24 bits deep of true color, image enhancement, edge enhancement, Super Image Enhancement, High Penetrate Strength, Display, Low Penetrate Strength Display, Image Magnifier, Brightening/Dimming, Image Recurrence, Image Restoration, Image Storage, Multi energy penetration the organic matter is orange, inorganic is blue, and the mixture is green. Working temperature / humidity 0℃~45℃/20%~95% (Not condensing) Storage temperature / humidity 20℃~60℃/ 20%~95% (Not condensing) working voltage 110VAC (±10%) 50±3Hz Noise 58DB. Approved

1

2482668

2482668

... More
Door Frame Metal Detector

-

-

-

... More
20 zone or above door frame metal detector nominal size : 760 mm (w) x 2050mm (H)x700mm (D) loaded with necessary software

1

218475

218475

... More
Parking Management System

-

-

-

... More
Entry ticket dispensor High-quality gloss finish of the front control panel with integrated ticket request button Illuminated Ticket Dispensor Panel Color : Silver/Grey Barcode ticket, QR code ticket Proximity Card/mifare/EM card Ticket up to 7000 tickets from one roll Graphical LCD-Display HOUSYS Intelligent Control board to store 1,00,000 offline records Voice Prompt InstructionInbuilt Loop Detector Communication with the data controller in RS485 or TCPIP Operating ambient temperature - 35°C/+65°C Offline work capability Inbuilt intercom- Optional Heater and fan with inbuilt thermostat Support variety of induction cards Offline storage capacity 1million transaction Dimension : 435 mm x 330 mm X 1360 mm. In built Loop detector Approved Makes: Houston Systems, USA ( HOUSYS), Metric ( UK), Swarco ( Switzerland), Tiba ( USA)

1

523015

523015

... More
Automatic boom barrier: Barrier Front Design Round Barrier Colour Silver/Grey Colour PARKI Electromechanical Drive Mechanism 3 meters boom arm Illuminated Boom Arm (Red/Green) Opening Speed : 1.5 Sec Reverse on Obstable Detection Housys intelligent control mechanism Automatic Fault Detection Led Indication on barrier body (Red/Green) Duty Cycle 100 % IP Rating : IP 55 RS 485 Communication Complete in all respect Approved Makes: Houston Systems, USA ( HOUSYS), Metric ( UK), Swarco ( Switzerland), Tiba ( USA)

1

183916

183916

... More
Manned Exit Station : Intel I3, with 3 MB cache, CPU 4460@ 3.2 Ghz, 4 GB RAM, 500 GB HDD 19" LCD Monitor, Keyboard & Mouse Microsoft Windows XP Professional license PARKSIM Parking Software Graphic User Display HOUSYS intelligent processing board Repecipt Printer HOUSYS Intelligent Controller Barcode Scanner Proximity Card Reader Cash Drawer Network Switch Complete in all respect Approved Makes: Houston Systems, USA ( HOUSYS), Metric ( UK), Swarco ( Switzerland), Tiba ( USA)

1

523015

523015

... More
Central Management Station Intel I3, with 3 MB cache, CPU 4460@ 3.2 Ghz, 4 GB RAM, 500GB HDD 19" LCD Monitor, Keyboard & Mouse Microsoft Windows XP Professional license CMS PARKSIM Software Hardware parameter updates and upgradation PARK ADMIN Graphical, clear presentation of the parking system Checking and controlling of the devices Functional alarm message reporting with direct access to detailed information Administering customer and card data and issuing various types of tickets Tariff module for the convenient design of car park tariffs PARK TARIFF Car park-specific tariff configuration Temporal tariff validity Linear, progressive and degressive tariff structure Tariffs for various payment types PARK REPORT Tabular and, if necessary, graphical presentation of car park data in various statistical and report formats with numerous settings Occupancy statics Periodical statics Value range statics Revenue statics ( ticket type, payment type) Season parker statics Maintenance, error and alarm list Complete in all respect Approved Makes: Houston Systems, USA ( HOUSYS), Photonplay technologies, Designa ( Germany), Tiba ( USA)

1

595840

595840

... More
Supply, Installation, Testing & Commissioning of IP 60fps driver face/ automatic number plate recording system/ recognition system including high resolution camera and software set for the driver face capture and automatic number plate recording camera with 2 nos face detection IP camera 2MP Motorized Varifocal Bullet 1920×1080@ 50FPS, 1/2.8" Progressive CMOS (Scanning System), Focal Length: Motorized Varifocal 5-50mm, Color 0.002lux @ F1.6(AGC ON); B/W 0 lux @ IR ON, IR Distance: 80m, BLC, 3D DNR, WDR: 120dB, AGC, White Balance, Electronic Shutter: 1/5 ~ 1/20000sec, Built-in microphone, Video Compression: H.264 & H.265, Unicast/Multicast Streaming, Video Streams: Triple-Stream, Mainstream @60fps 1080P(1920x1080),960P(1280x960),720P(1280x720), Sub steam @30fps 720P(1280x720), VGA(640x480), QVGA(320x240), Mobile stream @30fps VGA(640x480), QVGA(320x240) Bitrate: 256Kbps ~ 8Mbps, ONVIF( Profile S/G/T), camera makes bosch, mountxross, axis, pelco AI Support: Face Recognition, Human & Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Cross Counting, Stationary Object Detection, Heat Map, Crowd Density Detection, Queue Lenght Detection, license Plate Detection, Rare Sound Detection, Inbuild Micro SD slot: up to 256GB SD Card, IP67 & Metal Body, Certificates: CE, FCC & BIS. Included: Alarm: 1 input, 1 output, Audio: 1 input (RCA), 1 output (RCA).

2

126222

252444

... More
NVR shall have Embedded Linux. NVR shall support the following bandwidth - 1024 Mbps, Incoming 512 Mbps & Outgoing 512 Mbps. NVR shall support Video Output: HDMI (1 1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080, 3840*2160/EDID), HDMI 2(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080) Async output,VGA Output (1 1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080). NVR shall offer the following recording resolution streams Video Resolution: 8MP, 5MP, 3MP, 2MP(1080P), 1.3MP(960P), 1.0MP(720P). NVR shall support Preview Capability: multiple matrix mode, Supported frame rate: 4K:240fps, MP:480fps, 2MP:960fps. NVR shall support schedule-based snapshots, manual snapshot. NVR shall support Motion Detection. NVR shall support 4 zones Privacy Mask. NVR shall offer intelligent analysis functions powered including Human & Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Stationary Object Detection, Crossing Counting, Heat Map, Crowd Density Detection, Rare Sound detection (gunshot/baby crying/dog barking), Face Detection. AUDIO. NVR shall support G.711A/G.711U Audio compression. NVR shall integrate Audio input 1 CH RCA port. NVR shall integrate Audio output 1 CH RCA port, HDMI audio. Video Recording and Playback. NVR shall support 1-30fps Video Frame Rate. NVR shall have Record Mode: schedule, event-based - motion, I/O, PIR. NVR shall offer 16 CH max sync playback. NVR shall be able to playback according to different types, including Playback Mode Instant playback, Local video, local image. NVR shall support Record Search Time, calendar, channel search, and event search, (ANR, regular video, motion detection video, alarm video, intelligent detection video). NVR shall support the following Video Playback: Start, stop, normal play, back play, frame by frame forward, full screen, Fast forward / backward (2x, 4x, 8x,16x), Slow forward (1/2x, 1/4x, 1/8x,1/16x), Add custom/Default Tag, digital zoom, video clip, sub-stream/main-stream, playback video bar, scale of 30 mins to 24 hrs. Storage and Backup. NVR shall support RAID0, RAID1, RAID5, RAID6, RAID10. NVR Should have S.M.A.R.T info feature to check the health of HDD, temperature, and status. NVR shall offer Local, Network HDD NFS, SMB/CIFS. NVR shall offer USB mobile hard disk, U disk, network backup Method. NVR Should support FTP for uploading alarm video. NVR shall ANR Support Smart IPC (with SD card) ANR. Function. NVR shall support the following protocol: IPv4, IPv6, TCP/IP, HTTP, HTTPS, DDNS, RTMP, SMTP(SSL), SNMP, DHCP, PPPoE, UPnP, NTP, P2P, FTP, IP filter. NVR shall support ONVIF Profile S Support. NVR shall support ONVIF/RTSP/HTTP/HTTPS/RTMP port customized. NVR shall support Mobile Surveillance Support Apple, Android & Internet Explorer Support IE, Chrome, Firefox, Safari. NVR shall Digital Zoom support. NVR shall have IPC timing anual/auto/timing/reconnect timing. NVR shall support the following Event Actions: pre and post recording, Send email, show message, send email, FTP upload video or screenshot, Cloud upload video or screenshot, full screen, voice prompts, Alarm output trigger, PTZ linkage. NVR Should support a combination of different events for effective alarm trigger and response. NVR Shall have exception alarms on event type of no space on disk, disk error, video loss. NVR Shall be able to configure covert on camera by which recording is happening, but live view is restricted. Network Detection monitoring, Utilization of total and used bandwidth, IP filter with blacklist and whitelist. NVR Shall support video cover privacy mask both on live and recording up to 4 areas. NVR makes bosch, mountxross, axis, pelco shall have User Management User add, delete, modify, permission management, support. NVR Shall be able to trigger PTZ presets on any camera AI event. NVR shall support Security Mode authorized username and password, HTTPS with a password, RTSP Validation. NVR should Manage IPC Support IPC centralized management, including IPC parameter configuration, information export and import, real-time information acquisition and upgrade. NVR shall have Statistics of events for face recognition, vehicle & human, cross count and heat map. Network Interface. NVR shall integrate 2 X RJ45 10M/100M/1000M adaptive Ethernet port. Alarm Input 16 CH alarm input & Alarm Output 4 CH alarm output. NVR shall integrate 1* RS485,& USB2.0*1(front) USB3.0*1+USB2.0*1(rear). General. The power consumption shall be 12V/5A & Power Consumption ≤12W (Without HDD). Operation Temp./ Humidity -10°C ~ 55°C/10%-90%.

1

124737

124737

... More
Supply Installation, Testing & commissioning of HDD Formatted capacity 8 TB surveillance ,Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s,Cache (MB) 64,Rotational speed (RPM) IntelliPower ,Load/unload cycles4 300,000,Non-recoverable read errors per bits read 1 in 1014, Operating (2 ms, read/write) 30, Operating (2 ms, read)65, Non-operating (2 ms)250, Average power requirements (W) Read/Write 5.90,Idle 4.90,Standby and Sleep 0.40 complete in all respects.

1

36901

36901

... More
Supply Installation, Testing, commissioning & Laying of Cat 6 Cable in existing conduit Category 6 Unshielded Twisted Pair 23 AWG:305mtr. ,4 pair 100W cable shall be compliant with ANSI/TIA/EIA-568-C.2 Additional Transmission Performance Specifications for 4-pair 100W Category 6Cabling. Tested upto 600 MHZ; Construction: 4 twisted pairs separated by internal X shaped, 4 channel, polymer spine / full separator. Half shall not be accepted.Sheath : FRPVC/LSZH,Outer Diameter 6.1 mm nominal;Temperature Range -20° to +60°C.Manufacturer should have ISO 9001:2008 Certification for Quality Management System.Manufacturer should have ISO 14001:2004 Certification for Environmental Management System.All UTP and Its Components should be from same OEM.

200

86

17200

... More
SITC of L2+ Managed Industrial Grade POE Switch 10 Ports Gigabit Managed Industrial Grade POE Switch , 8 10/100/1000 Base- TX portand 2 Gigabit SFP slotand 1console port Network Protocols: Support , IEEE802.3, IEEE802.3u, IEEE802.3z , IEEE802.3ab , IEEE802.3x , IEEE802.1d , IEEE802.1w , support IP camera All Make. Netgear, Cisco. Mountxross, D link, should Working temperature:-40~75℃ Storage temperature:-40~85℃, Relative Humidity : 5%~95% (no condensation), Shell : IP30 protectgrade, metal shell Installation : DIN- Railor Wallmounts, MTBF : 300,000 hours , Support L2+ Switching features including 802.1Q VLAN, Mirroring, Portisolation, IGMP Snooping, DHCP Snooping, LLDP, IP Source Guard, ARP inspection, ACL setc. Support spanning tree STP(802.1D) and RSTP(802.1W).802.1s(MSTP) way exchange time 50ms Jumbo frames support upto 9.6 Kkilobytes Support enhanced managemen through WEB,CLI, TELNET, SSH, SNMP Ethernet port support 10/100/1000 Mself- adaption.Bandwidth: 24Gbps, Packet Buffer Memory: 4M Packet Forwarding Rate:1488000 pps /port Address Table : 8K

1

71575

71575

... More
SITC of Wall Mount 9U Rack ,Front Glass Door (tinted,Toughened) with Lock & Key,2 pairs of 19" Mounting Rails with U-Marking,Welded Side Walls With Metal Logo,1U Cable Manager (1), Hardware Packet (1 Pkt),6 Socket 5 Amp. Power Distribution Unit (1 No),Roof Mounted Fan Unit / 90 CFM /230V AC (1 No) complete in all respects as approved and desired by the Engineer in-charge at site

1

11060

11060

... More
SITC of Display Information sytem working on LAN ,43" 4K , UHD, Digital Signage,4000;1DVI-D,DP1.2,HDMIX2, HDCP2.2, Stereo mini Jack,USBX2, RS232C(in/out),RJ45,300NITS,MagicInfo Premium software,Multi Display Control Software,WI-FI,Auto Source recovery & switching,8Gb with Stand Memory

1

70536

70536

... More
HDMI Cable 3 mtr

2

5272

10544

... More
LIFTS

-

-

-

... More
pecification 1: 1 Nos./13 Person 884 Kgs /SUKRANTI (Without MachineRoom)/ 1mps speed/Travel 06 Mtr. (approx)/B+G+4/6 Stops/6 Openings/ Shaft Size required: 2400mmw x 1900mmd/Car Size: AS PER IS STD / Clear Opening: 900mmw x 2000mmh/Pit-1600mm/Headroom 4800mm/Center Opening doors / V3F Microprocessor based Selective Collective Simplex Control / Car-SS Honeycomb Finish /Centre Opening Power Operated Car Door in SS Honeycomb with Vision Panel (IS Std.) / Centre Opening Power Operated Landing Door in SS Honeycomb with Vision Panel (IS Std.) / 20 mm thick Granite / Automatic Rescue Device / Infra-Red Screen Sensor / Auto light & Fan off/Over Load Warning Indicator with announcement/SS Handrail/SS False Ceiling in Car / Dot Matrix Led D & P Indicators In Car & Landings - Orange Colour / Push Button Orange LED Illumination/2way intercom Press & Speak / Full Car operating panel /Full Load Bye pass/ Floor Annunciator with Music/ Sill Angle / Sill Support/Fireman's Switch / Battery Operated Alarm Bell and Emergency Light / Minor Builders Works / Scaffolding/Pit Ladder/ Free Service One Year/All std Govt. Features

-

-

-

... More
Car Entrance: Center Opening Automatic Doors in Stainless Steel Panels in hairline Finish Scratch Resistance/ Vandal proof with Vision Panel (Upto 40% area should be visible by glass) having a clear opening of 900mm (wide) x 2000mm (high) and contrasting in colour from the adjoining wall. There should be no difference in level between the lift door and the floor surface at each level. The gap between the lift door and building floor should not be more than 12 mm. Hoist way Entrance: Ground to Second Panel Center opening Automatic Door's of Stainless steel finish panel in Scratch Resistance/ Vandal proof with provision of emergency key opening at landings with a clear opening of 800mm (wide) x 2000mm (high) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attendant Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear)

-

-

-

... More
Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level and have a clear floor space minimum 900mmX1200mm Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level with no obstruction placed to prevent a wheelchair user from reaching it and have buttons with Braille/raised letters and in sharp contrast from the background to aid people with visual impairments Lift Signage: Signs indicating the location of an accessible lift should be provided in a location that is clearly visible form the building enterence. The sign should incorporate representation of the International Symbol for Access. A Sign indicating the number of the floor should be provided on each lift landing on the wall opposite the lift. It is also recommended to install a floor directory of the main facilities and services available on the lift landing, along with an accessible emergency egress route that clearly indicates the location of nearest refuge areas for Persons with Disabilities. Audio and Visual Indicators: The lift should have a voice announcement system along with a visual display to indicate the floor level and also the information that the door of the cage is open or closed for enterence or exit.The announcement system should be clearly audible.e. the announcement should be 50 decibel. Free service One years after the S/I/T/C work and all std. Govt. features

6

3321537

19929222

... More
Other Features : 1. Battery operated emergency light with rechargeable battery. 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close. 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28. The use of visually and acoustically reflective wall surfaces should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairments. 29. The floor of the lift car should be slip resistant and have similar frictional qualitites to the floor of the lift landing to decrease the risk of stumbling. 30. The provision of a mirror on the wall of the lift car opposite the lift door is a positive aid to navigation for wheelchair users. It allows the wheelchair user to see if anyone is behind them and also to see the floor indicator panel. The mirror should not extend below 900 mm from the lift door to avoid confusing people with impaired sight. 31. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids. 8 passenger lift to be provided, which allows easy maneuverability of wheelchair user.

-

-

-

... More
Escalator

-

-

-

... More
The Escalator shall be of State-of-the-art technology, having nominal step width of 1000 mm, with 3 nos. horizontal Steps on top and bottom landing area and the nominal speed will be 0.5 m/sec. For the aforesaid step width and nominal speed, maximum carrying capacity as per EN115-1:2008 will be 100 passengers per minute. The escalator shall be complete with all safety features and shall fully comply with International Standard EN-115 latest version. The Escalators shall be reversible type and capable of operating safely, smoothly and continuously in both directions for a period of not less than 20 hours a day, seven (7) days a week with an alternating passenger load reaching 100% of Contract Load (120 kg per step) for two hours and 50% of Contract Load for the following hour within the environmental conditions as stated in the specification and at the location where the escalators are to be installed The angle of inclination of escalator shall be 35° and minimum transition radius shall be 2.6 meters at the upper landing and 2.0 meters at the lower landing.

6

7099314

42595884

... More
Horticulture Works

-

-

-

... More
Supplying and stacking at site of work well decayed farm yard manure from approved site of work including screening through sieve of I.S. designation 16 mm with 5 km lead.

197.7

658

130173.09

... More
Supplying at site of work good quality top soil, free from debris and weeds, from approved site of work with 5 km lead.

2757.7

586

1618216.98

... More
Supplying of good earth/ soil-less media and/or organic matter, preparation of top dressing mixture or pot media

-

-

-

... More
Mixture of sand and vermicompost in ratio 1:1

272.41

3031

825939.76

... More
Fine grassing including uprooting rank vegetation and weeds by digging the area to a depth of 30 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days, mixing fertilizer and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, watering, weeding and maintenance for 30 days or till thick lawn is formed.

3891.64

131

512480.34

... More
Providing and fixing Selection no. 1 grass turf with earth 50mm to 60 mm thickness and ramming with required wooden tools, rolling with light roller to make the surface smooth and even.

-

-

-

... More
Maintenance of fine grass lawn for one year including fertilizer application, watering, weeding, top dressing with good earth and manure mixture, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads.

3891.64

51

200892.29

... More
Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control. CSR 32.13. 0.60x0.60x0.60=0.216

17.28

408

7063.34

... More
Supplying and planting permanent trees in prepared pits and watering

80

179

14327.6

... More
Maintenance of tree including fertilization, application of insecticide, watering, weeding, training, pruning, disposal of debris and other activities.

-

-

-

... More
Maintenance of trees for the 1st year

80

741

59333.12

... More
Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control. CSR 32.13. 0.60x0.60x0.60=0.216

54

408

22072.93

... More
Supplying and planting permanent shrubs in prepared pits and watering

250

69

17382.75

... More
Maintenance of shrubs for one year including training, pruning, fertilization, application of insecticide, watering and weeding.

-

-

-

... More
Individual shrubs

250

221

55308.75

... More
Planting seasonal flower in beds

-

-

-

... More
Planting seasonals at flowering stage in beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting at 20cm distance from plant to plant and row to row.

46.45

1074

49913.78

... More
Maintenance of seasonal flower beds including digging of beds to 15 cm depth mixing FYM, fertilizer and insecticides, planting of sapling at 20cm distance from plant to plant and row to row, three times a year.

46.45

834

38756.58

... More
Planting Rose beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, triangular planting of sapling at 60cm distance from plant to plant and row to row.

230.15

183

42188.57

... More
Maintenance of Rose beds for one year including application of FYM, fertilizer, insecticides, pruning and casualty replacement

230.15

165

38066.69

... More
Providing and fixing of white river (Stone) pebbles size of 2" to 2.50" dia in natural colour at site of work including loading, unloading and carriage

224.67

720

161895.85

... More
Supply and installation of garden bench

-

-

-

... More
Chair type garden bench with L-shaped sides made of reinforced concrete (M- 30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation

25

5582

139562.41

... More
Rectangular garden bench with h-shaped sides made of reinforced concrete (M- 30), thickness 100 mm, back height 750 mm, base width 450 mm. Back and seat shall consist of rectangular reinforced concrete planks 1500 mm x 350 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation

20

4176

83521.48

... More
Cast Iron bench of 1800 mm length, 900 mm width, 450 mm seating height, sides made of cast iron. Seat and back shall be made of 10 strips of M.S. pipes 63 mm x 25 mm of 14 gauge with one M.S. Flat 25 x 10 mm welded at the centre, below and back of the seat and back rest. Spray painted with approved brand paint. Fixed by grouting with 1:2:4 cement concrete (Minimum weight of each bench 105 kg)

15

13187

197815.7

... More
Supply of wooden planter covers for indoor pot plants.

-

-

-

... More
Wooden planter 420mm x 420mm x 420mm, consisting of 4 panels each made of 4 Nos wooden slats of size 420 mm x 38 mm x 38 mm, 20 Nos wooden slats of 420 mm x 38 mm x 25 mm, and 4 Nos water proof plywood sheets 4 mm thick of size 344 mm x 382 mm fixed on inner side of each panel fixed with nails, one coat of primer and two coats of enamel paint.

40

1809

72396.52

... More
Wooden planter for 10 inch pot, outer size 330mm x 330mm x 320mm, made of 30 mm x 20 mm horizontal wooden slats and 30 mm x 30 mm vertical slats fixed with nails, finished with spirit polish and varnish as per specifications complete.

50

2361

118097.35

... More
Providing and fixing vertical garden panels on aluminium tube (50 x25 x 1.5 mm) frame, fixed on wall, with growing media of cocopeat, perlite and vermiculite 2:1:1, amended with fertilizers and plants as specified by the engineer in Charge.

-

-

-

... More
Indoor vertical garden

30

9247

277428.69

... More
Outdoor vertical garden

40

8338

333538.1

... More
Maintenance of vertical garden for one year, complete with replacement of plants, panels, drip equipment etc., replenishing decomposed media, watering and fertilization.

-

-

-

... More
Indoor vertical garden

30

1073

32205.5

... More
Outdoor vertical garden

40

981

39274.48

... More
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. Boring with 250mm dia housing pipe up to 150 mtr. depth BGL.

60

976

58577.97

... More
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – incharge. 200 mm nominal size dia.

60

2007

120452.98

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia.

14

2848

39877.31

... More
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. 200mm internal diameter (weight 41.6 kg per metre) 8.0 mm thickness

1

4435

4435.21

... More
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.

1

2966

2966.66

... More
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. 200mm internal diameter

2

1082

2165.09

... More
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.

1

641

641.09

... More
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. 250mm internal diameter

1

819

819.33

... More
Foot Rest for Manhole. Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.

1

220

220.18

... More
Supply and installation of inline drip irrigation

-

-

-

... More
LDPE Emitting Pipe 16 mm; Class 2 (0.4 m x 1 to 4 Lph), complete with all accessories.

2500

18

47407.5

... More
Supply and installation of pop up sprinklers

-

-

-

... More
Pop up geared rotors 3/4" inlet and radius ranging from 7-12 m with interchangeable nozzles and all accessories complete and setting flow rate as directed.

175

1354

237090.18

... More
Provision for 7.50 hp submersible pumps along with pipes and hydrants.

1

496130

496130.88

... More
Providing and fixing pair of Plastic dustbins 100 litre volume each, of two different colours, for dry and wet waste, made of virgin plastic to be mounted on MS rectangular hollow section 50 x 25 x 3 mm frames pivoted on 3 MS square hollow section verticals, 1 m above ground, one 35 cm RHS welded to each vertical member at base and grouted in 180 x 40 x 30 cm 1:2:4 cement concrete.

60

13435

806117.13

... More
Planting ground covers (special) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.

1427.68

712

1016745.15

... More
Maintenance of ground cover (special) for one year including application of FYM, fertilizer, insecticides, pruning and casualty replacement

1427.68

264

377519.28

... More
Providing cement pots at site of work, filling 2/3rd volume with mixture of good earth and screened manure and cocopeat in the ratio 2:1:1. 60 cm size of pots

120

599

71932.98

... More
Supplying specimen pot plant in 45 cm cement pots for outdoor display at site of work.

120

968

116179.98

... More
Maintenance of outdoor specimen pot plants for one year.

120

766

92033.76

... More
Providing earthen pots at site of work, filling with mixture of screened manure, good earth andcocopeat in the ratio 2:1:1 as specified. 30 cm size of pots filled to full volume. CSR 32.37 d

300

107

32237.1

... More
Supplying pot plant in 30 cm pots with plastic plate for indoor display at site of work. In earthen pot. CSR 32.43 d

200

247

49514.5

... More
Supplying seasonal flowers in earthen pots at site of work, as specified by Engineer-in-charge. Planting and supplying seasonal plants in flowering stage in 25 cm size of pots.CSR 32.40

100

192

19279.05

... More
Maintenance of indoor pot plants for one year.CSR 32.44)

300

294

88494

... More
Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control. CSR 32.13. 0.75x0.75x0.75=0.42

201.6

408

82405.61

... More
Planting specimen plants in prepared pits and watering

480

1481

710986.08

... More
Maintenance of specimen plants for one year including, fertilization, application of insecticide, watering and weeding.

480

868

416680.32

... More
Add 1% Culture Cess

1516794143.54

-

15167941.44



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.