Public Works Department Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 3,12,590Document Cost
₹ 10,000Tender Fee
₹ 5,900
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CEPW_138718_1Tender No
3/2025-26Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwdpunjab.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
-
-
-
... More
Additional Length 25mm x 3mm thick Copper Tape
50
637
31858
... More
Additional Length 25mm x 5mm thick Copper Tape
50
1039
51990
... More
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
-
-
-
... More
Cable Tray Size 150mm x 50mm x 50mm (2mm thick)
30
1066
31990.5
... More
Cable Tray Size 300mm x 50mm x 50mm (2mm thick)
60
1455
87343.8
... More
XLPE INSULATED HT CABLES: XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND): Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:-
-
-
-
... More
HT Cable Overall size 70sq.mm (3Core)
80
1136
90921.6
... More
HT Cable Overall size 120sq.mm (3Core)
400
1458
583556
... More
S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:-
-
-
-
... More
Heat Shrinkable End Termination for cable size 120-185 sq. mm, 3Core (Indoor Type)
4
3772
15091.16
... More
Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Indoor Type)
4
3131
12524.84
... More
Supply & erection of 11kV GO switch confirming to ISI specifications. The item includes supply and erection of operating pipe and handle arrangement of MS flat 50mm x 6mm and channels 75mm x 40mm sheet. The GO switch is to be fitted with locking arrangement so as it locks upward on 'ON' position and locks downward in 'OFF' position. The entire GO switch assembly/unit should be properly earthed and the job is to be completed as approved by Engineer-in-charge.
1
11360
11360.1
... More
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. Depth not exceeding 3 m. BG
-
-
-
... More
All kinds of soil except rocky
180
104
18774
... More
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C.
inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
-
-
-
... More
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
18
6780
122045.94
... More
600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal
6
8970
53823.3
... More
Supply, Erection, Testing and Commisioning of 12kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type Extenable 3 no's VCB (Vacuum Circuit Breaker) switch board unit 800/630 Amp.totally factory assembled which includes 800/630 Amp. Vacuum Circuit Breaker for 1 no. Incoming and 2 no. Out goings VCB 800/630Amp. 'Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of Min. 21kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current:min 50 opeartion or more VCB parameters are as below: (a). Rated Voltage: 12kV
(b). Rated short circuit breaking current withstand : Min. 25kA for 3sec.
(c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak
(d). Rated insulation voltage( Power frequency withstand) : Min. 28kV
(e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO
(f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz)
(g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) VCB incorporating mechanical as well as electrical ON/OFF indiaction "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door.
Incomer shall consist of:
(a). Cast Resin CT's 11kV : 250-200/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA
(b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA (c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type
(d). Master Trip/ Anti pumping relay
(e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.
(f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.
(g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard
(h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations
All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments Outgoing shall consist of:
(a). Cast Resin CT's 11kV : 100-60/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection
(c). Master Trip/ Anti pumping relay
(d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal
(f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard
(g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations
All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:-
-
-
-
... More
11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type 3 no;s VCB (Vacuum Circuit Breaker) Switch board unit 800/630 Amp. which includes 1 No. 800/630 Amp. Vacuum Circuit Breaker for Incomer and 2 no. Out going feeder
complete in all respects as approved and desired by the Engineer-in-charge at site.. The Supervision,Inspection & testing at Manufactuers site(By department)
1
1887700
1887700
... More
Supply, installation, testing and commissioning of 11KV/433V Indoor/ Outdoor type floor mounted Distribution Transformer 1000KVA, totally factory assembled Three Phase 50 Hz, mineral Oil , Naturally Cooled ONAN, Core type Double wound with copper conductor cnforming to IS:1180 (2021) Level-2 (As Amendment -4) & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV
(c) On Load Tap changer + RTCC + AVR: +5% to -15% tapping in steps of 1.25%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C
(f). Oil/ Winding temperature rise: As per IS:1180
(g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side
(j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. and manufacturer shall ensure that there is no mixing of second grade core. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:- complete in all respect as approved and desired by the Engineer in-charges at site with in house core cutting facility.
-
-
-
... More
1000 KVA Three Phase Distribution Transformer 11KV/433V, 50 Hz,mineral Oil, Naturally Cooled ONAN, Core type Double wound with copper conductor having percentage impedence and Losses at 50% & 100% Loading conforming to IS:1180 (2021) Level-2 (As Amendment -4) DistributionTransformer
2
4200133
8400266
... More
Designing, Supplying, installation, testing &commissioning of Indoor cubical type Main LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 61439-1&2 -Partallyt Totally Type Tested panel with IP 42 (indoor type).LT Panel shall be tested for all type test as per IEC 61439-1&2 & IEC61641 with aluminum busbar,The manufacturer shall submit the all type test reports during drawing approval. (Dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system,IP54/55 and minimum 50kA. The Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 61439-1&2 . The Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C. The Supervision,Inspection & testing at Manufactuers site(By department)
Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet,,conforming to IS:8623. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The door should be double door design without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel.The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.
Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7 tank Powder coated process should present in company pemises) after necessary putty work . Busbar :- The panel shall be provided with TPN aluminium busbar of suitable size according to the size of ACB/MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium. All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports.The main busbar would be supported upon non-hygroscopic supports and Breaker should be compatible for communication on Modbus TCP/IP for future scope. ACB terminals should be rotatable type. Metering :- The panel shall complete with also have digital metering unit with selector switch (volt meter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. The switchboard Main distribution panel shall restrict the internal arcs faults within the compartment to ensure maximum safety to the operating personnel.
The ACB should be capable for recording 10 fault history, LCD Display of current & voltage, Icu = Ics = Icw (1 Sec.) = 50kA with no derating upto 50 degree celcius on the existing industrial panel (With terminal adapter on load and line side of breaker),
Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO9001:2015 standerd) and NABL Lab reports of calibiration. The Concerened contactor shall be provide the detailed drawing of panel with attested and submitted to department for approval with complete specification and approved from the Engineer in charge at site.
Bus Bar :- 2000A, TPN Aluminium Busbar suitable for with standing fault level of 50KA with heat shrinkable coloured sleeves i/c SMC/DMC bus bar supports at required intervals. (Current density shall be maximum 1.3 A/sqmm) Detail of ACB/MCCB's to be installed in the cubical panel Enclosure as per following .
-
-
-
... More
Main LT Panel ( SubStation -1 ) for Transformer (1000KVA)
Bus Bar :- 2000A, TPN Aluminium Busbar suitable for with standing fault level of 50KA with heat shrinkable coloured sleeves i/c bus bar supports at required intervals. (Current density shall be maximum 1.3 A/sqmm) Main Incomer:- 1. ACB 1600 Amps. EDO type FP, Icu = Ics = Icw (1 Sec.) = 50kA, microprocessor based trip sytem with thermal memory, zone selective interlocking, pre trip alarm, individual fault indicating LED, release with LSIG protection = 1No. and Multi Function Meter with display parameter of Voltage, Ampere, KW, KWH, KVA, Frequency, PF, % THD, phase angle and LED Cluster Indicating lamps and 2 Amp control MCB suitable size CTs = 1No. Outgoings:- . 1. MCCB 630Amp. Microprocesser based , Four Pole, 36KA Microprcoessor based release with (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle=5 no. (For no. 3 Charger Panel + 2 no. Spare) and Multi Function Meter with display parameter of Voltage, Ampere, KW, KWH, KVA, Frequency, PF, phase angle and LED Cluster Indicating lamps and 2 Amp control MCB suitable size CTs =4 no.,
2
711489
1422978
... More
Supply, Installing testing and commissioning of 2000A, 3P + 100% Neutral, 50KA For 1 Sec,Sandwich Type Bus trucking Straight Feeder Length,Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor 50 X 6 mm Aluminium and Suspension Hanging system etc. complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Compliance as per IEC 61439 part 1 & 6 .
60
28804
1728240
... More
Supply, installation, testing and commissioning Elbow vertical / Horizontal / off set Bend 2000Amp / 3P+1N+E complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
12
10602
127224
... More
Supply, installation, testing and commissioning Flange End Unit 2000Amp complete with hardware-nuts and bolts complete in all respects as approved and desired by the Engineer-in-charge at site.
6
15891
95346
... More
Supply, installation, testing and commissioning Copper Flexible 2000Amp complete with hardware-nuts and bolts complete in all respects as approved and desired by the Engineer-in-charge at site.
6
43395
260370
... More
Supply, installation, testing and commissioning of Adopter Box/tap off box for Transformer side and panel side 2000Amp. complete in all respects as approved and desired by the Engineer-in-charge at site.
6
13834
83004
... More
Supply of Rubber hand gloves suitable for 11KV. complete in all respects as approved and desired by the Engineer-in-charge at site.
2
794
1588
... More
Supply & fixing of shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks. complete in all respects as approved and desired by the Engineer-in-charge at site.
4
159
636
... More
Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. complete in all respects as approved and desired by the Engineer-in-charge at site.
20
142
2840
... More
Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. complete in all respects as approved and desired by the Engineer-in-charge at site.
20
99
1980
... More
Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
2
4778
9556
... More
Supply of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -1963. complete in all respects as approved and desired by the Engineer-in-charge at site.
2
1960
3920
... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments. complete in all respects as approved and desired by the Engineer-in-charge at site.
10
2024
20240
... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.complete in all respects as approved and desired by the Engineer-in-charge at site.
10
2977
29770
... More
fixing of Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity. complete in all respects as approved and desired by the Engineer-in-charge at site.
10
7163
71632.5
... More
Supply and fixing of foam fire extinguishers, Portable ABC type 6Kg capacity hanged on wall with bracket component as
required.
10
2953
29533.6
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%