Public Works Department Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Public Works Department - PWD Tender

Works
Telecommunication Services
Eprocure
Opening Date4 Sep 2024
Closing Date4 Oct 2024
Tender Amount₹ 4,06,48,231 
Notes
Download

Costs

  • EMD

    ₹ 8,13,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 5,900

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, installation, testing & Commissioning of Category 6 UTP patch cords shall be constructed of 24 AWG unshielded twisted pair stranded copper cable 2 Meter. Complete in all respect to the entire satisfaction of the engineer-in-charge .

63

11592

184

... More
Supply, installation, testing and commissioning of Category 6, RJ45, 8-position, 8-wire universal module (I/O) with Single gang, 86mm x 86mm shuttered faceplate with label slot. Accepts Dual Modules Complete in all respect to the entire satisfaction of the engineer-in-charge .

63

16002

254

... More
Supply, installation, testing & Commissioning of Wall Mounted Rack network Rack - 12U 500d, with Heavy Duty Extruded Aluminium Frame for rigidity. Fan 90CFM 230V AC, Cable manager 1U MS with Loops Shelf, PDU 6 Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Complete in all respect to the entire satisfaction of the engineer-in-charge.

3

22881

7627

... More
Supply, Installation, Testing & Commissioning of Cat 6 Cable should be Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 cabling system.Conductors should be 23 AWG solid bare copper Cable should be ETL Verified, UL Listed and UL channel verified- All three Certificates are mandatoryCable Should be with systems warranty; Warranty to cover Bandwidth of the specified and installed cabling system, and the installation costs. Site certificate Should be issued by OEM Frequency tested should be up to 600 MHz minimum Should be packing Box of 305M Complete in all respect to the entire satisfaction of the engineer-in-charge ..

1860

89280

48

... More
Supply, Installation, Testing and commissioning of 1 KVA Online UPS with input power factor correction 0.99 , output power factor 0.8 , inbuilt OVCD, effeciency above 90% , True online double conversion, internal bypass, LCD status display, Intelligent battery charging, Automatic periodic battery self test, Sine wave ouput, serial connectivity, Generator compatible with wide input voltage range, output voltage regulation , frequency regulation etc. with , SMF VRLA UPS Battery 12V 26AH 2 No.ensures long life suitable for charging 12 volts D.C. power backupwith with suitable metallic battery rack & UL Listed battery interlinks including petty material required during Installation, including connection & testing charges etc. complete in all respects as approved and desired by the Engineer-in-charge at site

3

84213

28071

... More
Cost of EPABX System Supply, Installation, Testing and commissioning of IP Based EPABX System Inbuilt IP card with Voicemail in all Extensions. Equipped with telephone exchange incoming 4 CO Ports, 50 SIP Extensions and shall be micro processor based on stored program Complete in all respect to the entire satisfaction of the engineer-incharge.

1

127113

127113

... More
Supply & erection of IP Telephone, PoE, SIP with Display, Redial, CLIP, 2 Way Speaker, Mute Compatible with EPABX System. Complete in all respect to the entire satisfaction of the engineer-in-charge

20

177960

8898

... More
Supply & erection of Executive IP Telephone, PoE, SIP with Large Backlit Display, Redial, CLIP, 2 Way Speaker, Mute Compatible with EPABX System including 1 year Warranty on site. Complete in all respect to the entire satisfaction of the engineer-in-charge

1

19067

19067

... More
Supply, Installation, Testing & Commissioning of Cat 6 Cable should be Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 cabling system.Conductors should be 23 AWG solid bare copper Cable should be ETL Verified, UL Listed and UL channel verified- All three Certificates are mandatory Cable Should be with systems warranty; Warranty to cover Bandwidth of the specified and installed cabling system, and the installation costs. Site certificate Should be issued by OEM Frequency tested should be up to 600 MHz minimum Should be packing Box of 305M Complete in all respect to the entire satisfaction of the engineer-in-charge ..

630

30240

48

... More
Cost of Online UPS 60KVA Supply, installation, testing and commisioning of 60 KVA Online UPS Overvoltage cut-off device (OVCD), Input power Factor 0.99, Output power Factor 0.9, 3 phase-3 phase, isolation transformer, Efficiency 94% with Advanced Battery Management System, Battery 42AH-100AH/12v for 120 minutes battery backup time, Battery Rack or Cabinet and Interlinks (UPS to battery cable upto 5mt.), Generator Compatible with Wide Input Voltage window (110 – 280Vac) for Indian Environmental Condition and for Optimized Battery Performance. UPS would support SNMP Manager and web browser complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

2743514

1371757

... More
Cost of Fire Alarm and Evacuation System PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 1.5sq.mm (48/0.20mm), 2Core

460

22047

47.93

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-

-

-

-

... More
PVC Flexible Pipe 25mm dia.

30

537

17.91

... More
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Powder Coated Concealed Metal Box with Brass Lugs One/Two Module

30

2345

78.17

... More
Supply, Erection, Testing and Commisioning of of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm 2 Loop Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. Designed to meet UL864, 10th Edition. Complete in all respect to the entire satisfaction of the engineer-in-charge .

1

374347

374347

... More
Supply, Installation, Testing and Commissioning of Digital Audio Amplifier. Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of 100 W at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall (be Wall/Panel Mounted) not be rail mounted / dependant on Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of Amplifier operation. The Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers shall provide back up of minimum 5 hours using secondary power source(battery power/UPS power) Complete in all respect to the entire satisfaction of the engineer-in-charge .

1

193465

193465

... More
Supply, Erection, Testing & commissioning of Inbuilt automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH with Emergency evacuation Control Panel & Digital Voice command system with Battery Dress Panel. Complete in all respect to the entire satisfaction of the engineer-in-charge .

1

61650

61650

... More
Supply, Installation, Testing and Commissioning of Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on the same peer-to-peer Network and 2 ways Communication capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. Products not having this feature must provide dedicated CPU for DVC. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. The panel shall be capable of self programming without any dependency on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for programming the panel with all necessary licence. Panel shall have Modbus/ Bacnet over IP protocol for future integration with BMS. However, for the present arrangement the FA system will be standalone with 24x7 monitoring. The panel shall be capable of remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th Edition. Complete in all respect to the entire satisfaction of the engineer-in-charge

1

315239

315239

... More
Supply, Installation, Testing and Commissioning of Remote Paging Station for Zone selection & paging to selected area in case of emergency.. Complete in all respect to the entire satisfaction of the engineer-in-charge

1

31143

31143

... More
Supply, Installation, Testing & Commissioning of OEM of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th Edition Complete in all respect to the entire satisfaction of the engineer-in-charge .

233

829247

3559

... More
Supply, Installation, Testing & Commissioning of OEM Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Complete in all respect to the entire satisfaction of the engineer-in-charge .

3

10296

3432

... More
Supply, Installation, Testing & Commissioning of OEM Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. Complete in all respect to the entire satisfaction of the engineer-in-charge .

20

69920

3496

... More
Supply, Installation, Testing & Commissioning of OEM Addressable Manual Call Point (Pull down Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Complete in all respect to the entire satisfaction of the engineer-in-charge .

10

57200

5720

... More
Supply, Installation, Testing & Commissioning of OEM Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.Complete in all respect to the entire satisfaction of the engineer-in-charge .

10

43220

4322

... More
Supply, Installation, Testing & Commissioning of OEM Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed Complete in all respect to the entire satisfaction of the engineer-in-charge .

10

44490

4449

... More
Supply, Installation, Testing & Commissioning of single/ double sided Glow Type EXIT SIGNAGE for 20 mtrs. view: SL20,NM,IP42,60lm,3Hr. EN compliant, 3 hours battery back-up, built in Ni-cd battery with miimum size 250mmx200mm. Acrylic sheet on side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Complete in all respect to the entire satisfaction of the engineer-in-charge.

8

40680

5085

... More
Supply & erection of powder coated junction box (deep) 1" x 3 " with petty material required at the site. complete in all respects as approved and desired by the Engineer-in-charge at site.

392

21952

56

... More
Supply and drawing of Un Armoured Fire Survival 2 C X 1.5 Sq mm multi stranded twisted unshielded FRLS Copper cable (SLC, NAC, DAL, Telephone) in pipe / on surface with clamps Complete in all respect to the entire satisfaction of the engineer-in-charge.

2952

357192

121

... More
Supply, Installation, Testing & Commissioning of Stored Pressure Fire Extinguisher, ISI Marked, CE and EN Certified, Pure Polyester Powder Coated Body with Plastic skirt, CE Marked Forged brass valve having Pressure Relief Device and NRV for pressure gauge port, Vinyl label, QR Code. MMO ABC 6 Kg IS:15683 Stored Pressure (Fire Rating 4A 144B ) Complete in all respect to the entire satisfaction of the engineer-in-charge.

8

47792

5974

... More
Supply, Installation, Testing & Commissioning of OEM 6W Wall Mount/ Ceiling Speaker with suitable included size boxes and Frequency Response 200Hz - 15kHz, with Line Matching transformer 100V. Variable tapping 1.5W/3W/6W, SPL@1M - 82dB, Peak SPL 84dB. Complete in all respect to the entire satisfaction of the engineer-in-charge

126

256284

2034

... More
Supply, Installation, Testing & Commissioning of OEM Power Amplifier 100 Volt amplifer,Rated power 480W, 70V, 100V, Frequency Response 60-15KHz,S/N Ratio = 70dB,THD 0.1% at 1KHz,4-16 ohm speaker outputs,Isolated transformer, Balanced XLR type line input and unbalanced phone jack line input, Balanced XLR type line output feeds to another power amplifer Complete in all respect to the entire satisfaction of the engineer-in-charge

1

61014

61014

... More
Supply & Laying of Cable & Accessories::Speaker Cable 1.5 sqmm in PVC Conduit should be laid in existing PVC/HDPE pipe complete in all respect as desired by the engineer in charge.

1512

83160

55

... More
Supply, Installation, Testing & Commissioning of BIS Certified Self Contained Rechargeable Wall Mounted Emergency Egress Routes Lighting , Maintained Type , ingress protection IP 20 , Housing CRCA Sheet 22 SWG fabricated, Message printed on 2mm thick milky acrylic, Supply voltage 230VAC, Supply current 50mA max, Number of LEDs - 20 (0.2W), Viewing distance 24M, Ambient temperature -25°C to +60°C, , INDICATIONS Mains ON: Red LED ON, CIRCUIT POWER - Overall: 5W - On mains (LED): 3W - On battery (LED): 3W, PROTECTION - Protection Protection class: Class I, Low battery cut-off: 2.4±0.1V ,Over charge cut-off: 4.2±0.1V , BATTERY - Charging method: Constant Voltage - Back-up duration: 120 minutes - Recharging period: 10-18 hours - Battery type: 3.7V lithium ion - Battery capacity: 2200mAH, Conforms to IS 10322, BIS Certified Part 5 / Sec - 8 Complete in all respect to the entire satisfaction of the engineer-in-charge.

16

211856

13241

... More
Supply, Installation, Testing & Commissioning of BIS Certified Self Contained Rechargeable Surface Mounted Emergency Egress Routes Lighting , Maintained Type , ingress protection IP 20 , Housing CRCA Sheet 22 SWG fabricated, Message printed on 2mm thick milky acrylic, Supply voltage 230VAC, Supply current 50mA max, Number of LEDs - 20 (0.2W), Viewing distance 24M, Ambient temperature -25°C to +60°C, , INDICATIONS Mains ON: Red LED ON, CIRCUIT POWER - Overall: 5W - On mains (LED): 3W - On battery (LED): 3W, PROTECTION - Protection Protection class: Class I, Low battery cut-off: 2.4±0.1V ,Over charge cut-off: 4.2±0.1V , BATTERY - Charging method: Constant Voltage - Back-up duration: 120 minutes - Recharging period: 10-18 hours - Battery type: 3.7V lithium ion - Battery capacity: 2200mAH, Conforms to IS 10322, BIS Certified Part 5 / Sec - 8 Complete in all respect to the entire satisfaction of the engineer-in-charge.

12

184308

15359

... More
Supply, Installation, Testing & Commissioning of BIS Certified Self Contained Rechargeable Emergency,Non Maintained Type , ingress protection IP 65 , Housing Molded ABS, White in colour,Diffuser Molded Polystyrene, Opal reeded finish Supply voltage 230VAC, Supply current 50mA max, Number of LEDs - 20 (0.2W), Ambient temperature -25°C to +60°C,LED Make Edison, Luminous flux 180Lm.Automatic, Relay, Ra 40. PTI 600V, INDICATIONS Mains ON: Red LED ON., CIRCUIT POWER Overall: 5W. Protection class: Class I Low battery cut-off: 2.4±0.1V Over charge cut-off: 4.2±0.1V PROTECTION Charging method: Constant Voltage. Back-up duration: 180 minutes, Recharging period: 10-18 hours Battery type: 3.7V lithium ion,Battery capacity: 2200mAH BATTERY Mounting type | Surface mounting Weight | 2 Kg. approx. Complete in all respect to the entire satisfaction of the engineer-in-charge.

43

382614

8898

... More
Supply & Erection of SUPER glow Series Self Maintain Photoluminescent SWGS Plan/Siganages in 1 mm thick Rigid Sheet SUPERGLOW RIGID SHEET with Strong Self Adhesive ,Life : 10- 15 Years ,Weather Proof  The sign can easily be cleansed with a dry cloth or with a cloth humidified with water (without detergents). , Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe , Non Peelable, Non Scratchable,Non  Breakable, Silk Screen Printed: high quality paint with UV resistance,As Per PSPA Class - A / DIN 67510 Part 2 / 60 Minutes / 700 mcdl with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period 24 Hrs DRDO & ARAI Certified for All require QC test to Confirm As per the IS 9457-2005 ,IS 12349 (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White. Complete in all respect to the entire satisfaction of the engineer-in-charge.

-

-

-

... More
Cost of FLOOR INDICATOR (Minimum size 250mm x 200mm)

8

16272

2034

... More
Cost of IN CASE OF FIRE DO NOT USE LIFT USE STAIRS (Minimum size 200mm x 200mm)

8

13016

1627

... More
Cost of FIRE ACTION BOARD (Minimum size 450mm x 600mm)

4

43932

10983

... More
Cost of EMERGENCY EVACUATION PLAN (Minimum on A2 (420mm x 594mm))

4

51860

12965

... More
Cost of CCTV Surveillance System Supply, Installation, Testing & Commissioning of 5 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 2592 × 1944 at 25fps, 2.8 mm Fixed lens, 0.003 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, BLC, HLC, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), Alarm : 1 inputs & 1 outputs, Audio: 1 input & 1 output, , , IP67, IK 10, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Face capture, Region entrance detection, Region exiting detection, Video tampering, Audio exception detection, Focus on human and vehicle targets classification based on deep learning UL, CE, FCC certified. complete in all respects as approved and desired by the Engineer-in-charge at site.

26

247858

9533

... More
Supply, Installation, Testing & Commissioning of 5 MP IR Fixed Bullet Network Camera -1/2.7″ Progressive Scan CMOS, 2592 × 1944 at 25fps, 2.8 mm Fixed lens, 0.003 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, BLC, HLC, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), Alarm : 1 inputs & 1 outputs, Audio: 1 input & 1 output, , , IP67, IK 10, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Face capture, Region entrance detection, Region exiting detection, Video tampering, Audio exception detection, Focus on human and vehicle targets classification based on deep learning UL, CE, FCC certified. complete in all respects as approved and desired by the Engineer-in-charge at site.

6

57198

9533

... More
Supply, Installation, Testing & Commissioning of 32 Channel Network Video Recorder & Management System with required Licenses for all of the above mentioned Complined Cameras complete with all necessary required software's, Hardware's, Storage, Accessories, Civil, Electrical works & peripheral items required as per specifications & at site of work inline with the engineer in charge instructions. The system proposed should have minimum usable 30 days recording suitable Hard Disk as per requirement with 256MBPS throughput. Should support 8 SATA of 8 TB each With RAID 5/6. Certifications: ONVIF Profile S Compliant, UL, CE, Compliant.complete in all respects as approved and desired by the Engineer-in-charge at site. .

1

48727

48727

... More
Supply, Installation, Testing & Commissioning of 8TB Hard disk Surveillance Complete in all respect to the entire satisfaction of the engineer-in-charge . .

2

40676

20338

... More
Supply, Installation, Testing & Commissioning of 43 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W) Complete in all respect to the entire satisfaction of the engineer-in-charge ..

1

40676

40676

... More
Supply, installation, testing and commissioning of 24-port POE 1GbE L2+ Mannaged switch with 4X1GbE SFP (upgradeable to 10GbE) uplink ports complete in all respects as approved and desired by the Engineer-in-charge at site. .

2

162704

81352

... More
Supply, Installation, Testing & Commissioning of Category 6, punchdown patch panels shall terminate 4-pair, 22 – 26 AWG, 100 ohm unshielded twisted pair cable Complete in all respect to the entire satisfaction of the engineer-in-charge .

2

10678

5339

... More
Supply, Installation, Testing & Commissioning of Category 6 UTP patch cords shall be constructed of 24 AWG unshielded twisted pair stranded copper cable 1 Meter.Complete in all respect to the entire satisfaction of the engineer-in-charge .

32

5088

159

... More
Supply, Installation, Testing & Commissioning of Wall Mounted Rack network Rack - 9U 500d, with Heavy Duty Extruded Aluminium Frame for rigidity. Fan 90CFM 230V AC, Cable manager 1U MS with Loops Shelf, PDU 6 Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Complete in all respect to the entire satisfaction of the engineer-in-charge .

2

13770

6885

... More
Supply, Installation, Testing & Commissioning of Cat 6 Cable should be Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 cabling system.Conductors should be 23 AWG solid bare copper Cable should be ETL Verified, UL Listed and UL channel verified- All three Certificates are mandatoryCable Should be with systems warranty; Warranty to cover Bandwidth of the specified and installed cabling system, and the installation costs. Site certificate Should be issued by OEM Frequency tested should be up to 600 MHz minimum Should be packing Box of 305M Complete in all respect to the entire satisfaction of the engineer-in-charge ..

960

46080

48

... More
Cost of Display TV & Token Machine System RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring Networking socket point RJ45 (one module)

7

3156

450.9

... More
Supply, Installation, Testing & Commissioning of 55 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W) Complete in all respect to the entire satisfaction of the engineer-in-charge .

1

82623

82623

... More
Supply, Installation, Testing & Commissioning of Token Calling Display System having screen size 4 inches, Voice calling/ Bell System, complete key pad Etc, calling display up to 60 meter cable (5 meter length included), serial communication design, Text Color Red Display Shape Rectangle,Power 5 W,Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital,Cash counter etc, Warranty 1 Year,220 VAC Operating Voltage Character Capacity 3 Character, Power Consumption,Rectangular Metal body ,complete in all respect as approved and desired by the Engineer in-charges at site

3

31143

10381

... More
Supply, Installation, Testing & Commissioning of Cat 6 Cable should be Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 cabling system.Conductors should be 23 AWG solid bare copper Cable should be ETL Verified, UL Listed and UL channel verified- All three Certificates are mandatoryCable Should be with systems warranty; Warranty to cover Bandwidth of the specified and installed cabling system, and the installation costs. Site certificate Should be issued by OEM Frequency tested should be up to 600 MHz minimum Should be packing Box of 305M Complete in all respect to the entire satisfaction of the engineer-in-charge ..

150

7200

48

... More
Cost of Nurse call System RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring Networking socket point RJ45 (one module)

139

62675

450.9

... More
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Powder Coated Concealed Metal Box with Brass Lugs One/Two Module

82

6409

78.17

... More
Supply, Installation, Testing & Commissioning of System on Chip Based design to make system versatile Control & Embedded Technology based NCP with Multi colour LCD screen along with different voice announcement. Nurse Call Station, with Larger Multi colour LCD screen. LCD display: 1024X768 (min) pixels. Dimensions 19” LCD send indicator information to all the rooms, show various rooms call status on LCD TV and announce call status with high quality voice. Colour coded room number display with call description. Provision to view Call Status of all the Nurse stations from any work station on network. Call forwarding and Call escalation features Display of calls in the order of originating time. Complete in all respect to the entire satisfaction of the engineer-in-charge .

6

1189776

198296

... More
Supply, Installation, Testing & Commissioning of Bed Side Module is a Composite Calling Unit comprising of Nurse Call function, Code Blue, Additional Help function and reset button, call function indicators with 3 colours 5 mm. solid state LED lamp with attached Patient Handset. Dimension : Standard 3 electrical switches modules; sizes 116L X 89W X 53H mm; Bed head panel Cut out Dimension 76mm x78mm (WxH); Complete in all respect to the entire satisfaction of the engineer-in-charge .

51

790908

15508

... More
Supply, Installation, Testing & Commissioning of Patient Hand Module consisting of recessed 1 nos. call buttons for calling nurse, call status indicators with 3 colour LED lamps including 2.5 mtrs flexible cord. Call can be incited directly from the patient hand set ,3 different Led indicators show the status of call. Complete in all respect to the entire satisfaction of the engineer-in-charge .

51

84252

1652

... More
Supply, Installation, Testing & Commissioning of Door Indicator Supply of a corridor Lamp Module that shall be configured as a room call lamp, a direction lamp and as a ward lamp. It shall be required for optical indication of calls, presences and reminders in the relevant colours Complete in all respect to the entire satisfaction of the engineer-in-charge .

12

45756

3813

... More
Supply, Installation, Testing & Commissioning of Toilet Pull Cord System Complete in all respect to the entire satisfaction of the engineer-in-charge .

19

57969

3051

... More
Supply, Installation, Testing & Commissioning of Cat 6 Cable should be Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 cabling system.Conductors should be 23 AWG solid bare copper Cable should be ETL Verified, UL Listed and UL channel verified- All three Certificates are mandatoryCable Should be with systems warranty; Warranty to cover Bandwidth of the specified and installed cabling system, and the installation costs. Site certificate Should be issued by OEM Frequency tested should be up to 600 MHz minimum Should be packing Box of 305M Complete in all respect to the entire satisfaction of the engineer-in-charge ..

2460

118080

48

... More
Supply, installation, testing & Commissioning of Wall Mounted Rack network Rack - 12U 500d, with Heavy Duty Extruded Aluminium Frame for rigidity. Fan 90CFM 230V AC, Cable manager 1U MS with Loops Shelf, PDU 6 Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Complete in all respect to the entire satisfaction of the engineer-in-charge.

6

45762

7627

... More
Cost of 11KV Sub Station 400KVA 2 no's (For HVAC & Building EI+Power) XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-

-

-

-

... More
Overall size 150sq.mm (3½ Core) Un-armoured (Loose)

200

139326

696.63

... More
Overall size 185sq.mm (3½ Core) Un-armoured (Loose)

1120

969012

865.19

... More
Overall size 240sq.mm (3½ Core) Un-armoured (Loose)

40

44563

1114.08

... More
Overall size 300sq.mm (3½ Core) Un-armoured (Loose)

80

108404

1355.06

... More
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 2.5sq.mm (10 Core)

40

14133

353.34

... More
COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:

-

-

-

... More
Earthing with 25mm x 5mm Copper Tape (upto 14Metre in Length)

20

519548

25977.41

... More
Earthing with 40mm x 5mm Copper Tape (upto 14Metre in Length)

2

68538

34269.3

... More
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-

-

-

-

... More
Additional Length 25mm x 5mm thick Copper Tape

100

103980

1039.8

... More
Additional Length 40mm x 5mm thick Copper Tape

30

48937

1631.24

... More
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-

-

-

-

... More
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)

20

6519

325.95

... More
ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-

-

-

-

... More
On Load Change Over Switch Four Pole 800amp., 415volts (For bypass switch in Main LT panels)

2

89492

44746.04

... More
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-

-

-

-

... More
Cable Tray Size 150mm x 50mm x 50mm (2mm thick)

10

10663

1066.35

... More
Cable Tray Size 300mm x 50mm x 50mm (2mm thick)

20

29114

1455.73

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-

-

-

-

... More
Double Walled Corrugated HDPE Pipe 120/ 103.5mm (Outer/ Inner dia.)

900

261693

290.77

... More
Double Walled Corrugated HDPE Pipe 180/ 152mm (Outer/ Inner dia.)

40

17066

426.67

... More
XLPE INSULATED HT CABLES: XLPE INSULATED HT ARMOURED CABLES (LOOSE): Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid loose in the existing trench or pipe:-

-

-

-

... More
HT Cable Overall size 35sq.mm (3Core) ( Fom Meter Room VCB Outgoings to Transformer-1&2

40

22502

562.57

... More
HT Cable Overall size 70sq.mm (3Core) ( Fom Meter Room to VCB Main in Sub Station Room)

80

60782

759.78

... More
S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:-

-

-

-

... More
Heat Shrinkable End Termination for cable size 35 sq. mm, 3Core (Indoor Type)

4

11097

2774.29

... More
Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Indoor Type)

2

6262

3131.21

... More
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-

-

-

-

... More
Aluminium thimble cable Core size 70sq.mm

16

505

31.61

... More
Aluminium thimble cable Core size 95sq.mm

8

294

36.87

... More
Aluminium thimble cable Core size 120sq.mm

4

181

45.3

... More
Aluminium thimble cable Core size 150sq.mm

56

3067

54.78

... More
Aluminium thimble cable Core size 185sq.mm

24

1567

65.32

... More
Aluminium thimble cable Core size 240sq.mm

12

1264

105.35

... More
Aluminium thimble cable Core size 300sq.mm

24

2933

122.21

... More
Plain and reinforced Concrete Pipe:- Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc.

-

-

-

... More
R.C.C Pipe NP-2 150 mmm i/d Pipe

60

30657

510.95

... More
Cement concrete 1:6:12 With brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type

30

115800

3860.02

... More
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.

-

-

-

... More
Depth not exceeding 3 m. BG All kinds of soil except rocky

90

9387

104.3

... More
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.

-

-

-

... More
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal

2

13560

6780.33

... More
600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal

8

71764

8970.55

... More
Supply, Erection, Testing and Commisioning of 12kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type Extenable 1no's VCB (Vacuum Circuit Breaker) switch board unit 800/630 Amp.totally factory assembled which includes 800/630 Amp. Vacuum Circuit Breaker for 1 no. Incoming cum Out goings VCB 800/630Amp. 'Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of Min. 21kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 100 opeartion

-

-

-

... More
VCB parameters are as below: (a). Rated Voltage: 12kV (b). Rated short circuit breaking current withstand : Min. 25kA for 3sec. (c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak (d). Rated insulation voltage( Power frequency withstand) : Min. 28kV (e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO (f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz) (g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) VCB incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door. Incomer shall consist of: (a). Cast Resin CT's 11kV : 150-100/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA

-

-

-

... More
(c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type (d). Master Trip/ Anti pumping relay (e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments.

-

-

-

... More
Outgoing shall consist of: (a). Cast Resin CT's 11kV : 150-100/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection (c). Master Trip/ Anti pumping relay (d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal (f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:-

-

-

-

... More
11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type 3no;s VCB (Vacuum Circuit Breaker) Switch board unit 800/630 Amp. which includes 1 No. 800/630 Amp. Vacuum Circuit Breaker for Incomer cum Out going feeder complete in all respects as approved and desired by the Engineer-in-charge at site. Besides this the manufactures should have NABL accredited labortary certificate. The Supervision,Inspection & testing at Manufactuers site(By department)

1

536477

536477

... More
Supply, Erection, Testing and Commisioning of 12kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type Extenable 3 no's VCB (Vacuum Circuit Breaker) switch board unit 800/630 Amp.totally factory assembled which includes 800/630 Amp. Vacuum Circuit Breaker for 1 no. Incoming and 2 no. Out goings VCB 800/630Amp. 'Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of Min. 21kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 100 opeartion

-

-

-

... More
VCB parameters are as below: (a). Rated Voltage: 12kV (b). Rated short circuit breaking current withstand : Min. 25kA for 3sec. (c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak (d). Rated insulation voltage( Power frequency withstand) : Min. 28kV (e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO (f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz) (g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) VCB incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/ service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door. Incomer shall consist of: (a). Cast Resin CT's 11kV : 150-100/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA

-

-

-

... More
(c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type (d). Master Trip/ Anti pumping relay (e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments.

-

-

-

... More
Outgoing shall consist of: (a). Cast Resin CT's 11kV : 100-50/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection (c). Master Trip/ Anti pumping relay (d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal (f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:-

-

-

-

... More
11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type 3no;s VCB (Vacuum Circuit Breaker) Switch board unit 800/630 Amp. which includes 1 No. 800/630 Amp. Vacuum Circuit Breaker for Incomer and 2 no. Out going feeder complete in all respects as approved and desired by the Engineer-in-charge at site. Besides this the manufactures should have NABL accredited labortary certificate. The Supervision,Inspection & testing at Manufactuers site(By department)

1

1578793

1578793

... More
Supply, installation, testing and commissioning of 11KV/433V Indoor/ Outdoor type floor mounted Distribution Transformer 400KVA, totally factory assembled Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor cnforming to IS:1180 (2014) Level-1 (As Amendment -4) & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV (c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C (f). Oil/ Winding temperature rise: As per IS:1180 (g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side (j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp

-

-

-

... More
The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer testing labotatory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:- The Supervision,Inspection & testing at Manufactuers site(By department)

-

-

-

... More
400 KVA Three Phase Distribution Transformer 11KV/433V, 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor having percentage impedence and Losses at 50% & 100% Loading conforming to IS:1180 (2014) Level- 1 (As Amendment -4) DistributionTransformer complete in all respect as approved and desired by the Engineer in-charges at site

2

4273260

2136630

... More
Designing, Supplying, installation, testing &commissioning of Indoor cubical type Main LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 61439-1&2 with IP 42 (indoor type). The Panel shall be tested for all type test as per IEC 61439-1&2 & IEC61641 with aluminum busbar, The company shall submit the all type test reports during drawing approval. (Dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system,IP54/55 and minimum 50kA. The Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 61439-1&2 and IEC 61921. The Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. The Supervision,Inspection & testing at Manufactuers site(By department) Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet,,conforming to IS:8623. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The door should be double door design without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement.

-

-

-

... More
The Panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel.The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7 tank Powder coated process should present in company pemises) after necessary putty work . Busbar :- The panel shall be provided with TPN aluminium busbar of suitable size according to the size of ACB/MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium. All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports.ACB terminals should be rotatable type.

-

-

-

... More
Metering :- The panel shall complete with also have digital metering unit with selector switch (volt meter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Electrical and mechanical (castle kay) interlocking should be provided between the two incomers and Buscoupler to ensure that only one supply is available at a time on each section of bus to eliminate any possiblility of accidentally approaching two supplies at one bus section. The switchboard Main distribution panel shall restrict the internal arcs faults within the compartment to ensure maximum safety to the operating personnel as per IEC 61641. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO9001:2015 standerd) and NABL Lab reports. The Supervision,Inspection & testing at Manufactuers site(By department). The Concerened contactor shall be provide the detailed drawing of panel from company designed attested and submitted to department for approval with complete specification and approved from the Engineer in charge at site. Bus Bar :- 1000A, TPN Aluminium Busbar suitable for with standing fault level of 50KA with heat shrinkable coloured sleeves i/c SMC/DMC bus bar supports at required intervals. (Current density shall be maximum 1.3 A/sqmm) Detail of ACB/MCCB's to be installed in the cubical panel Enclosure as per following .

-

-

-

... More
Main LT Panel ( SubStation -1 ) for Transformer T1& T2 ( 400KVA) Bus Coupler :- 1000 Amps. FP Icw=50kA for 1 sec ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G & variable time delay setting. Release with LCD Display for Energy Parameter with %age loading of graph, Last 10 trip history, ZSI feature, Individual fault Indication. Copper Terminal adaptors on both side of ACB is required contact - 1 Nos Main Incomer:- 1. ACB 800 Amps., EDO FP Icw=50kA for 1 sec Microprcoessor based release with LSIG protection = 2No. and Multi Function Meter with display parameter of Voltage, Ampere, KW, KWH, KVA, Frequency, PF, % THD, phase angle and LED Cluster Indicating lamps and 2 Amp control MCB suitable size CTs = 2No. Outgoings:- 1. MCCB 630Amp. Microprocesser based , Four Pole, 36KA Microprcoessor based = 2No., 2. MCCB 400Amp. Microprocesser based , Four Pole, 36KA Microprcoessor based = 2No., 3. MCCB 100Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA= 2no., 4. MCB 63Amp. FP, 10KA= 4no. ,5. Empty compartment for Future Provision 250A MCCB=4no. , 7. On Load change over switch 630Amp. FP = 2no.

1

1476757

1476757

... More
Supply , fixing , connecting and testing of OEM Factory Manufactured / Company TTA APFC Panel with 7% reactor of capacity 125 KVAR @ 440V along with Capacitors 525V. The stage ratings shall be 1 X 50 KVAR + 1 x 25KVAR + 2 x 12.5KVAR + 1 x 10KVAR+ 3 x 5KVAR, The incomer of Each Capacitor Bank should having MCCB 36/25ka as per standards , Ics = 100% Icu & Power Contactors of same rating. The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 61439-1&2 and IEC 61921. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. As equipment shall be comprising of the following:-

-

-

-

... More
1. Insulated bus bar pan assembly made from copper and rated of 320/400 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. 2. The incomer of the APFC Panel shall be a 320/400 Amp MCCB / 36KA/4P/TP Microprocessor based LSIG protection. The MCCB shall be of certified design confirming to IEC 60947-1,2 & 3., Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier. 3. Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993,13341-1992 & IEC -60831-1&2.

-

-

-

... More
4. Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics= 50kAThe MCCB shall be of certified design confirming to IEC 60947-1,2 & 3. 5. PF Regulator : Advanced Range PF Regulator shall have 6 steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326. 6. Stage Contactor & Reactor : The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1. The de-tuning reactors shall be connected in series with each capacitor stage and shall be of iron cored type.The Detuned Reactor Should be equipped with Thermal Switch inside the Winding which should cut-off the respective contactor in case of Over-temperature. Tolerance of reactors shall not exceed +/-3% of rated value.

-

-

-

... More
7. Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer. Note:- Manufacturer/Company of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer / Company workshop as per ISO9001:2015 standerd). The warranty period will be start after complete commissioning. The Supervision,Inspection & testing at Manufactuers site (By department in contractor scope). The Concerened contactor shall be provide the detailed drawing of panel from OEM designed attested and submitted to department for approval with complete specification in all respects as approved and desired by the Engineer-in-charge at site For Main LT Panel APFC ( Proposed SubStation ) for Transformer T1 & T2 ( 400KVA)

2

1041986

520993

... More
Supply and erection of Dry Chemical powder (DCP) type Fire extinguisher 6Kg ISI mark: 15683 complete with squeeze type lever, hose, filled with ISI mark powder IS 4308 Complete in all respect as desired by engineer in charge of the work.

12

66108

5509

... More
Supply and erection of writing shock chart (Calendar Type) Complete in all respect as desired by engineer in charge of the work.

2

2590

1295

... More
Supply and erection of providing and fixing of fire bucket with MS hook stand complete in all respect as desired by engineer in charge of the work.

12

13032

1086

... More
Supply and erection of Non skkid rubber mat ISI 1000mm x 2000mm x 12mm for 11 KVA supply complete in all respect as desired by engineer in charge of the work.

20

37800

1890

... More
Supply and erection of Medical Kit complete in all respect as desired by engineer in charge of the work.

2

3008

1504

... More
Supply and erection of Danger Plate 11000 volts and 440 volts size 200mm x 150mm complete in all respect as desired by engineer in charge of the work.

4

1308

327

... More
Supply of 11 KV HT Glovees complete in all respect as desired by engineer in charge of the work.

2

1816

908

... More
Supply and erection of Fire Round Ball on the top the transformer ceiling mount with nuts and bolts ISI mark Complete in all respect as desired by engineer in charge of the work.

5

76675

15335

... More
Supply, Installation, Testing and commissioning of 1 KVA Online UPS with input power factor correction 0.99 , output power factor 0.8 , inbuilt OVCD, effeciency above 90% , True online double conversion, internal bypass, LCD status display, Intelligent battery charging, Automatic periodic battery self test, Sine wave ouput, serial connectivity, Generator compatible with wide input voltage range, output voltage regulation , frequency regulation etc. with , SMF VRLA UPS Battery 12V 26AH 2 No.ensures long life suitable for charging 12 volts D.C. power backupwith with suitable metallic battery rack & UL Listed battery interlinks including petty material required during Installation, including connection & testing charges etc. complete in all respects as approved and desired by the Engineer-in-charge at site

3

84213

28071

... More
Supply, Erection, Testing and Commissioning of Servo Voltage Stabilizer 400 kVA, Liner Type, Roller Carbon Bonik, Indoor, 3 Phase, Unbalance Type, Input Voltage 340 to 460 Volts, Output voltage 400 Volts plus minus 1 percent, (Outdoor Front should be GI Fabricated with IP64 Powder coating) With LCD Ampere Meter Three Phase With LCD Volt Meter Three Phase With LCD Volt Meter Single Phase With LCD Amperes Meter Single Phase With LCD Power Factor Meter With LCD Frequency Meter With MCB Protection for Control Circuit With Enclosure Acrylic Oil Certificate Provided IS335 Tested Sealed Drum. Copper Certificate Provided 99.9% Electrical Copper Grade Front Panel GI Sheet Fabricated with IP64 With Byepass Panel Powder Coating Tank Auto/Manual operation, Efficiency more than 99%, Company Should be ISO 9001,CE,ROHS certified Warranty 5 Year Onsite complete in all respect as desired by engineer at site:-

2

1682544

841272

... More
Making of Cement concrete foundation of size 1500mm X 1500mm X 300mm high for Transformer (Approx.) with 10cm below ground level and 20 cm above ground level. The foundation start with bedding of Base course of floor consisting of cement concrete 1:8:16. The top of the foundation covered with 4" Reinforced cement concrete M-20 type concrete mixer slab vicrated by needle vibrator and finished with 12.5mm thick cement plaster in ratio 1:4. complete in all respect as per site requirement and as desired by the Engineer in charge.

4

174000

43500

... More
Cost of Security Lighting System PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 1.5sq.mm (48/0.20mm), 3Core

120

8053

67.11

... More
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-

-

-

-

... More
Overall size 10sq.mm (3Core) Un-armoured (On-Surface)

440

47511

107.98

... More
AUTOMATIC VOLTAGE STABLIZER, TIMER: TIMER: S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:-

-

-

-

... More
Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)

1

15361

15361.08

... More
LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS: Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-

-

-

-

... More
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement

20

15254

762.73

... More
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-

-

-

-

... More
Aluminium thimble cable Core size 10 - 16sq.mm

128

1888

14.75

... More
Aluminium thimble cable Core size 25 -35sq.mm

8

143

17.91

... More
Supply and Erection of LED Flood Light 120watt (including LED driver) with pressure die cast aluminium housing with control gear ( with IP 65/ IP 66 protection), CRI Minimum 70, CCT 5700K, toughened glass fitting, LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270 volt, THD 10% ingress protection (as per BIS standards) , surge protection 10kv and above (as per (IS/IEC standards) wattage of each LED High power LED of 1 watt to 5 watt with mandatory modular lenses, input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.

8

82520

10315

... More
Supply and Erection of LED Flood Light 50watt (including LED driver) with pressure die cast aluminium housing with control gear ( with IP 65/ IP 66 protection), CRI Minimum 70, CCT 5700K, toughened glass fitting, LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270 volt, THD 10% ingress protection (as per BIS standards) , surge protection 10kv and above (as per (IS/IEC standards) wattage of each LED High power LED of 1 watt to 5 watt with mandatory modular lenses, input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.

6

25284

4214

... More
Cost of 2 no's Silent DG Set 250KVA (For HVAC & Building EI+Power) COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-

-

-

-

... More
Earthing with 25mm x 5mm Copper Tape (upto 14Metre in Length)

8

207819

25977.41

... More
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-

-

-

-

... More
Additional Length 25mm x 5mm thick Copper Tape

16

16636

1039.8

... More
Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 250KVA/200KW with AMF Panel, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 (With CPCB-4 Norms upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.

-

-

-

... More
ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled

-

-

-

... More
Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.

-

-

-

... More
AUTOMATIC MAIN FAILURE CONTROL PANEL: The Control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, MCCB (Fixed Thermal and Adjustable Thermal protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site

2

6143572

3071786

... More
Making of Cement concrete foundation of size 5400mm X 2400mm X 750mm high for DG Set with 150mm below ground level and 600mm above ground level. The foundation start with Earth Work in excavation in foundations, bedding of Base course of floor consisting of cement concrete 1:8:16, Shuttering for faces of concrete foundations and foundations, Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator,Cold twisted deformed (Ribbed/for Steel Bar) Bar Fe 500 grade as per IS 1786-2008, for R.C.C. works and finished with 12.5mm thick cement plaster in ratio 1:4 and Cost of shed included as Plinth size to cover DG with the material of Fiber/iron sheets, angle, Channels, or iron pipes complete in all respect as per site requirement and as desired by the Engineer in charge.

2

288128

144064

... More
Cost of On Grid Solar Power Generating System of 38kw Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum 38 KWp including required quantities of SPV modules (High power density Monocrytalline based) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Required Earthing (i.e. 2 Nos.GI Strip/ Chemical copper bonded rods Earthing for GI Structure, 2Nos. GI Strip /Chemical copper bonded rods Earthing for String Inverter, AC & DC Distribution System), ESE Stroke master (As per NFC 17 102 Standard with suitable radius of protection) with 3 Nos. chemical earthing with copper bonded rods, along with high rise GPSP structure (Rated Wind Speed 170Kph) including mounting height upto 8 feet Complete with transportaion, fabrication, labour & Civil Work. Features:-

-

-

-

... More
1. Solar PV Module Warranty 25 Years & Certified Under IS/IEC 61730 I & II, IS/ IEC 61701 & IS/IEC 14286 2. Power Conditioning Unit (String Solar Inverter) & Certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529 3. Structure : 25 Years Service Life with AMC & Certified under IS 2062:2011 4. Complete Plant Insurance for the period of 5 Years (Excluding Theft of the material) 5. Annual Maintenance Contarct for the period of 5 Years The Work will got done from approved MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency)/ PSPCL approved Contractors. The Rates are inclusive of all taxes including GST

38

2145594

56463

... More
Cost of 26 Passenger Hospital stretcher Lift (2 Nos.) Type and Capacity : Approximately 1768 Kg( Deep) , 26 Passengers cum Stretcher/ Hospital Lift without Machine Room Speed: 1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately 12 Meter (Ground to Second Floor) Serving: 4 Floors 4 Stops 4 Openings 4 Levels (All on the same side) Hoist way : 2500mm (Wide) x 3000mm (Deep) Clear dimensions Headroom Height (HR): 5000mm beyond finished floor level of last landing Pit Depth : 1800mm below the finish floor level of first landing Car Size Area: Minimum 3.74 square meter & Maximum 3.85 square meter Car Enclosure : Constructed out of stainless steel finish panel in Scratch Resistance/ Vandal proof Car Entrance: Center Opening Automatic Doors with vision panel (Upto 40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 1200mm (wide) x 2000mm (high)

-

-

-

... More
Hoist way Entrance: Center opening Automatic Door's with vision panel (Upto 40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with provision of emergency key opening at landings with a clear opening of 1200mm (wide) x 2000mm (high) Door operation : Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level

-

-

-

... More
Other Features : 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock

-

-

-

... More
15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close. 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.

2

7199280

3599640



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.