Public Works Department Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date14 Aug 2024
Closing Date13 Sep 2024
Tender Amount₹ 13,77,38,000
Costs
EMD
₹ 27,55,000Document Cost
₹ 50,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDBR_135961_1Bid Award Id
ViewTender No
Tender No. 03 dated 09-08-2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://pmgsytenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.
1528.05
-
-
Granular Sub Base (GSB)
-
-
-
Construction of granular sub base by providing well graded material, spreading in uniform layers on prepared surface, mixing by mix in place method at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical specification clause 401 (Relaying of retrived material to be recieved from dismentling)
1647.66
-
-
Wet Mix Macadam
-
-
-
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
2358.77
-
-
Primer Coat
-
-
-
Providing and applying primer coat with bitumen emulsion (SS-1) Bulk on prepared surface of granular base including cleaning of road surface and spraying primer at the rate 0.85 kg/sqm using mechanical means as per Technical specification clause 502
10363.31
-
-
Tack Coat (with VG-10 bitumen @ 0.275 kg/ sqm)
-
-
-
Providing and applying tack coat with Bitumen VG-10 using tar boiler / pressure distributor at the rate of 0.275 kg. per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical specification clause 503
92885.62
-
-
Dense Bituminous Macadam (DBM) ( with VG-30 bitumen)
-
-
-
Providing and laying Dense bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder VG-30, transported to site laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.
4644.28
-
-
Bitumenous Concrete (BC)
-
-
-
Providing and laying Bituminous Concrete with 100-120 TPH Batch Type HMP producing average output of 75 Tonne of per House using crushed Aggregate of specified grading, premixed with bituminous binder @ 5.50 % by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, , level and alignment, rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of MORT&H specifications
2787.36
-
-
Structure Work (Hume Pipe Culverts, Slab Type Culverts, Widening of Bridge, Repair of Culvert, Side Drains, Retaining Walls etc.)
-
-
-
Earth work in Excavation
-
-
-
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per technical specification clause 300
8020.93
-
-
Providing concrete for P.C.C grade M 10 Nominal mix 1:3:6 plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
378.15
-
-
Providing concrete for P.C.C grade M 15 plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
293.5
-
-
Providing concrete for P.C.C grade M 20 plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
212.44
-
-
Providing concrete for RCC M-20 Grade Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
281.52
-
-
Providing concrete for RCC M-25 Grade Plain/reinforced cement concrete in open foundation complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
42.61
-
-
Providing concrete for R.C.C grade M 30 plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
1677
-
-
Providing concrete for RCC M-30 Grade Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
1138.5
-
-
Brick Masonry work in Cement Mortar 1:4 in Foundation complete excluding Pointing and Plastering as per Drawing and Technical
Specifications 600, 1202, & 1203
1026.12
-
-
Brick Masonry work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering as per Drawing and Technical
Specifications 600, 1202, & 1203
104.86
-
-
Brick masonry work in cement mortar 1:3 in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 602, 603, 604, 1202 & 1204
125.01
-
-
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
134.16
-
-
Supplying, fitting and placing TMT bar reinforcement (Fe500) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
117.12
-
-
Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii) complete as per drawing & technical specifications clauses 800 & 1100
12.12
-
-
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding
excavation, protection works, backfilling concrete and masonry works in head walls and parapets (600mm dia)
45
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
3350
-
-
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
1525.5
-
-
Plastering 15mm with cement mortar (1:4) on brick work in substructure as per Technical specification 613.4, &1204.
6092.18
-
-
Pointing with cement mortar 1:3 (Deep variety) on brick work as per drawing and Technical specification clause 613.3 and 1204
333
-
-
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
503.18
-
-
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause
1701
14000
-
-
Provision of an Reinforced cement concrete crash barrier at the edges of the Bridge, road, approaches to bridge structures and medians constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified-with concrete mixture. CSR 22.12 (A) 3393.60 - GST 12%
30
-
-
Provision for road signage boards as per NRIDA Guidelines (First Revision-2019) and IRC:67 & other road furniture
-
-
-
Retro-reflectorised Traffic Signs 900x900x900mm triangular
-
-
-
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
20
-
-
Retro-reflectorised Traffic Signs 600x600x600mm triangular/octagonal/ circular Boards
-
-
-
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
40
-
-
Retro-reflectorised Regulatory Traffic Signs circular 600 mm Boards on Sharp curves
-
-
-
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
25
-
-
Direction and Place Identification signs with size 900x600mm
-
-
-
Providing and erecting direction and place identification retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on 2no. mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
11
-
-
Direction and Place Identification signs with size 600x450mm
-
-
-
Providing and erecting direction and place identification retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on 2no. mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
10
-
-
Direction and Place Identification signs with size 1200x900mm
-
-
-
Providing and erecting direction and place identification retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on 2no. mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
6
-
-
Providing and fixing Maintenance Informatory with logo board
-
-
-
Providing & fixing of typical Maintenanace informatory sign board with logo as per NRIDA Guidelines (Ist Revision-2019) and IRC:67-2012 and drawing. MS Plates 1.6 mm thick duly welded with ms angle iron frame of 25mmx 25mm x 3mm. size on back edge. The plates welded with MS flat of 50mm X 5 mm. The flat iron frame will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 600mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed syntheic enamal of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1.
2
-
-
Providing and fixing of typical PMGSY informatory sign board with Logo
-
-
-
Providing & fixing of typical PMGSY informatory sign board with logo as per NRIDA Guidelines (Ist Revision-2019) and IRC:67-2012 and drawing. The ACP Plates of 3mm thick, top and middle plate duly ribbted with MS flat iron 25mmx 5m size on back on edges. The lower ACP plate 4mm will be ribbted with MS angle iron frame of 25mmx 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be ribbted to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro reflectorised Tape (Class A/Class B) in reqiured shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1.
2
-
-
Providing and fixing of Standard PMGSY Logo Sign Board Double Sided
-
-
-
Providing & fixing of typical PMGSY Logo as per NRIDA Guidelines (Ist Revision-2019) and IRC:67-2012 and drawing. All M.will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro reflectorised Tape (Class A/Class-B) in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of expoy paint as per drawing Clause 1701 and Annexure 1700.1.
18
-
-
Providing and Fixing Citizen Informatory Board of PMGSY Project/ Maintenance Board
-
-
-
Providing and fixing of typical PMGSY Citizen informatory sign board as per NRIDA Guidelines (Ist Revision-2019) and IRC:67-2012 and drawing. Two ACP Plates of 4mm thick duly ribbted with MS angle iron frame of 25mmx 25mm x 3mm. The angle iron frame will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 600mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro reflectorised Tape (Class A/Class B) in reqiured shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1.
4
-
-
Hazard Marker sign board 300x900mm rectangular as per IRC 67-2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2mm thick aluminium sheet with 25x25x3mm angle iron frame supported on a mild steel angle iron post 65x65x6mm firmly fixed to ground including foundation concrete 1:2:4 of size 0.45x0.45x0.60m for vertical post complete as per technical clause 801 of MORT&H specifications
100
-
-
Chevron Sign Board 500x600mm (Double board at a site)
-
-
-
Providing and erecting direction and place identification retro-reflectorised (Class A/Class B) Sign as per (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over over ACP Sheet 3.00 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 750 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
70
-
-
Road Furniture
-
-
-
5th Kilometre Stones
-
-
-
Providing and fixing 5th Km. stones of standard design including painting and printing, etc as per drawing and Technical Specification Clause 1703.
3
-
-
Kilometre Stones
-
-
-
Providing and fixing Km. stones of standard design including painting and printing, etc as per drawing and Technical Specification Clause 1703.
16
-
-
200m Stones
-
-
-
Providing and fixing 200m stones of standard design including painting and printing, etc as per drawing and Technical Specification Clause 1703.
70
-
-
Boundary Pillar
-
-
-
Providing and fixing of boundary pillars of standard design as per drawing and Technical Specification Clause 1704
89
-
-
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.
1100
-
-
Providing and fixing of Delinators (Roadway Indicators) not less than 800mm high above ground level. The delinator shall have a core & shell construction which shallbe madeof tough, high impact resistant, injection - moulded, thermoplastic outer body. The inner core shall consist of powder coated or painted mild steel of minimum thickness1.00mm, The delinatorshould have top retro-reflective unit consisting of white colour micro prismatic non matallic retro reflective sheeting on both sides having minimum exposed area of 125 sq.cm each side and bottom retro reflectiveunit consisting of red colour micro prismatic non matallic retro reflective sheeting on both sides having minimum exposed area of 35 sq.cm each side confirming to ASTM D4956 type XI standards. The delinators shall be fixed to the ground by inserting the root of the delinators upto the marked portion and by firm concrete filling as per the instructions by the Engineer-in-charge
155
-
-
Providing and making rumble strips 15-20mm high at centre, 250mm wide placed at 1m centre to centre over freshly laid bituminous layer by using close graded premix surfacing material type B at approved locations to control speed and marked with 100mm wide white strips of thermoplastic road marking paint. The close graded premix surfacing material type B shall conform to technical clause 512 and thermoplastic road marking paint shall conform to technical clause 803 of MORT&H specifications
1365
-
-
Marking of Centre line, Zebra line, with hot applied thermoplastic road marking paint material conforming to MORT&H clause 803.4.2 and marking complete as per clause 803 of MORT&H specifications 2004 (upto date revision).
5591.55
-
-
For 1st Year
16.32
-
-
For 2nd Year
16.32
-
-
For 3rd Year
16.32
-
-
For 4th Year
16.32
-
-
For 5th Year
16.32
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements