Public Works Department Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date29 Dec 2023
Closing DateCancelled
Tender Amount₹ 15,38,09,883 
Notes
Download

Costs

  • EMD

    ₹ 30,76,200
  • Document Cost

    ₹ 50,000
  • Tender Fee

    ₹ 5,900

Summary

Construction Of Critical Care Unit G Plus 3 Storey In Civil Hospital At Barnala Punjab

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cement Concrete 1:4:8 With stone aggregate 40mm gauge. mixing by mechanical means using concrete mixer volumetric type

153.21

700828

4574.3

... More
Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.

534.93

3592937

6716.65

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

944.18

208890

221.24

... More
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.

189.94

1047460

5514.69

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.

996.35

7480426

7507.83

... More
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.

-

-

-

... More
Total all Floors all items

28.07

194569

6931.57

... More
Extra rate for First Floor

6.24

1189

190.68

... More
Extra rate for Second Floor

5.05

1925

381.37

... More
Extra rate for Third Floor

5.02

2871

572.05

... More
Extra rate for Fourth Floor

0.83

474

572.05

... More
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.

-

-

-

... More
Total qty for all floor

3389.45

1899651

560.46

... More
Extra rate for First Floor

824.31

8688

10.54

... More
Extra rate for Second Floor

829.12

17469

21.07

... More
Extra rate for Third Floor

838.58

26507

31.61

... More
Extra rate for Fourth Floor

90.75

3824

42.14

... More
Centring and shuttering for Columns (Square or Rectangular or ply gonal in plain)

-

-

-

... More
Total qty for all floor

2037.68

1023974

502.52

... More
Extra rate for First Floor

424.8

4477

10.54

... More
Extra rate for Second Floor

424.8

8950

21.07

... More
Extra rate for Third Floor

424.8

13427

31.61

... More
Extra rate for Fourth Floor

81.52

3435

42.14

... More
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels

-

-

-

... More
Total qty for all floor

2130.88

853055

400.33

... More
Extra rate for First Floor

531.2

5598

10.54

... More
Extra rate for Second Floor

519.6

10947

21.07

... More
Extra rate for Third Floor

523.44

16545

31.61

... More
Extra rate for Fourth Floor

32.48

1368

42.14

... More
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.

-

-

-

... More
Total qty for all floor

486.43

228554

469.86

... More
Extra rate for First Floor

93.64

986

10.54

... More
Extra rate for Second Floor

93.64

1972

21.07

... More
Extra rate for Third Floor

93.64

2959

31.61

... More
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc

1152.32

491660

426.67

... More
Extra rate for First Floor

247.65

2610

10.54

... More
Extra rate for Second Floor

247.65

5217

21.07

... More
Extra rate for Third Floor

247.65

7828

31.61

... More
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same has been deducted )

1684.49

220044

130.63

... More
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)

1684.49

156169

92.71

... More
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey

-

-

-

... More
Extra Rate for First Floor

242.98

5632

23.18

... More
Extra Rate for Second Floor

242.98

11262

46.35

... More
Extra Rate for Third Floor

245.27

17053

69.53

... More
Extra Rate for Fourth Floor

24.42

2263

92.71

... More
Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005.

-

-

-

... More
Total qty for all floor

201.51

1598633

7933.27

... More
Extra rate for First Floor

47.74

7342

153.81

... More
Extra rate for Second Floor

47.28

14544

307.62

... More
Extra rate for Third Floor

46.32

21373

461.43

... More
Extra rate for Fourth Floor

15.59

9591

615.24

... More
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.

-

-

-

... More
Total qty for all floor

107.07

605911

5659.02

... More
Extra rate for First Floor

30.47

4686

153.81

... More
Extra rate for Second Floor

23.87

7342

307.62

... More
Extra rate for Third Floor

24.51

11309

461.43

... More
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure.

-

-

-

... More
Total Qty for all floor

2580.69

1982460

768.19

... More
Extra rate for First Floor

576.07

9101

15.8

... More
Extra rate for Second Floor

596.35

18850

31.61

... More
Extra rate for Fourth Floor

682.27

32346

47.41

... More
Extra rate for Fifth Floor

112.73

7125

63.21

... More
Extra rate for Sixth Floor

11.29

892

79.01

... More
12.5mm thick cement plaster 1:5.

3495.18

696834

199.37

... More
Extra rate for First Floor

743.83

1569

2.11

... More
Extra rate for Second Floor

814.02

3427

4.21

... More
Extra rate for Third Floor

976.82

6173

6.32

... More
Extra rate for Fourth Floor

59.27

499

8.43

... More
20 mm thick cement plaster 1:5 in two coats work.

3495.18

955057

273.25

... More
Extra rate for First Floor

743.83

1569

2.11

... More
Extra rate for Second Floor

814.02

3427

4.21

... More
Extra rate for Third Floor

976.82

6173

6.32

... More
Extra rate for Fourth Floor

59.27

499

8.43

... More
12.5 mm thick cement plaster 1:4.

1132.99

235435

207.8

... More
Extra rate for First Floor

224.22

473

2.11

... More
Extra rate for Second Floor

234.2

985

4.21

... More
Extra rate for Third Floor

331.91

2097

6.32

... More
Extra rate for Fourth Floor

109.49

923

8.43

... More
20 mm thick cement plaster 1:4.

1132.99

325100

286.94

... More
Extra rate for First Floor

224.22

473

2.11

... More
Extra rate for Second Floor

234.2

985

4.21

... More
Extra rate for Third Floor

331.91

2097

6.32

... More
Extra rate for Fourth Floor

109.49

923

8.43

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp

-

-

-

... More
U-PVC pipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia.

141.42

37544

265.48

... More
U-PVC pipes (working pressure 4 kg / sqcm) pipe 160 mm dia.

135.32

64152

474.08

... More
Providing and fixing U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.

-

-

-

... More
UPVC 110 mm bend

14

1991

142.22

... More
UPVC 160 mm bend

12

1934

161.19

... More
Providing and fixing SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.

-

-

-

... More
UPVC 110 mm Coupling /Sockets

77

6813

88.49

... More
UPVC 160 mm Coupling /Sockets

74

8575

115.89

... More
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.

26

2902

111.64

... More
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.

26

19390

745.8

... More
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating

26

2284

87.87

... More
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing

33.1

25506

770.59

... More
Terracing consiting of machine made Hollow Clay Tiles 80mm thick (Smooth surface) confirming to IS: 3951 (Part-I)-2009 laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm on top of R.C.C. slab including grouting with cement sand mortar 1:4 having 10mm wide joints spacing on all sides of tiles and top surface to be left clean complete as per specification (laying shall be done as per PWD specifications).

-

-

-

... More
Total all Floor

834.5

867245

1039.24

... More
Extra rate for Third Floor

799.2

7576

9.48

... More
Extra rate for Fourth Floor

35.3

446

12.64

... More
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

170.07

12309

72.38

... More
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads.

511.37

266423

521

... More
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres.

559.5

37134

66.37

... More
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material

797.39

445111

558.21

... More
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material

1899.23

421496

221.93

... More
Extra rate for First Floor

611.39

1931

3.16

... More
Extra rate for Second Floor

604.46

3820

6.32

... More
Extra rate for Third Floor

683.38

6478

9.48

... More
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..

101.66

351953

3462.06

... More
Extra rate for First Floor

25.47

80

3.16

... More
Extra rate for Second Floor

26.8

169

6.32

... More
Extra rate for Third Floor

23.7

224

9.48

... More
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)

30.9

5794

187.52

... More
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

813.1

946757

1164.38

... More
Extra rate for First Floor

275.54

870

3.16

... More
Extra rate for Second Floor

117.79

744

6.32

... More
Extra rate for Third Floor

152.4

1444

9.48

... More
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing

81.19

114892

1415.11

... More
Extra rate for First Floor

23.1

73

3.16

... More
Extra rate for Second Floor

12.5

79

6.32

... More
Extra rate for Third Floor

20.43

193

9.48

... More
Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 Sqm

602.36

945054

1568.92

... More
Extra rate for First Floor

150.59

475

3.16

... More
Extra rate for Second Floor

150.59

951

6.32

... More
Extra rate for Third Floor

150.59

1427

9.48

... More
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.

1063.1

138872

130.63

... More
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm

1780.7

2688963

1510.06

... More
Extra rate for First Floor

393.34

1242

3.16

... More
Extra rate for Second Floor

534.34

3377

6.32

... More
Extra rate for Third Floor

471.68

4471

9.48

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.

1780.7

332047

186.47

... More
Providing and laying plain coloured 3.20mm gauge linoleum covering to floors laid dry. The term linoleum has been derived from the Latin words linum, meaning linseed, and oleum, meaning oil. Linoleum flooring can be described as a type of flooring that makes use of solidified linseed oil (linoxyn) as the base, along with wood flour, tree resins, cork dust, a touch of ground limestone and pigments (for adding color).

86.86

66250

762.73

... More
Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.

10.03

10961

1092.87

... More
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)

-

-

-

... More
Total all Floor

143.72

275923

1919.87

... More
Extra rate for First Floor

33.19

104

3.16

... More
Extra rate for Second Floor

33.56

212

6.32

... More
Extra rate for Third Floor

41.83

396

9.48

... More
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect

-

-

-

... More
(Railing on Enterance Ramp Design as per guidelines issued for persons with disability)

-

-

-

... More
(Railing on Ramp for upper storey Design as per guidelines issued for persons with disability)

-

-

-

... More
Railing on Stairs

1320.8

669288

506.73

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :

-

-

-

... More
For fixed portion & Chaukhat

6354.44

2356416

370.83

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required

9788.7

3794981

387.69

... More
Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop .

16143.14

1156494

71.64

... More
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet

91.87

301485

3281.65

... More
Providing and Fixing Single Glazing with 6mm thick glass with high perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge.

484.52

811604

1675.07

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)

132.77

144768

1090.37

... More
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1) (1999) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick

176.21

428264

2430.42

... More
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (including cost of glass) Rectangular or square

67

27033

403.49

... More
Providing and fixing 0.50mm thick aluminum sheet including cost of necessary fittings i.e. screws, etc. complete

156.63

81845

522.54

... More
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm

828.78

96917

116.94

... More
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm

83

17400

209.65

... More
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete ISI designation no I (Size of door up to 700mm)

54

56149

1039.8

... More
Providing & fixing teak wood railing size 150mm x 75mm on wall in corridor including polishing complete in all respect.

415.97

849718

2042.74

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.

78.23

844801

10798.95

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete

2057.8

16209105

7876.91

... More
Extra rate for First Floor

348.62

4776

13.7

... More
Extra rate for Second Floor

339.25

9292

27.39

... More
Extra rate for Third Floor

341.97

14051

41.09

... More
Extra rate for Fourth Floor

35.17

1926

54.78

... More
Extra rate for using steel produced in integrated plant from original ores complete in all respect as per the directions of Engineer-in-charge.

2057.8

809271

393.27

... More
Providing & fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitered and welded with 15x3mm lugs, 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

147.48

16780

113.78

... More
Providing and fixing 14 gauge MS sheet garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates including locking arrangement with handles etc. complete in respects

13.01

53453

4108.65

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge

121.82

158368

1300.02

... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.

-

-

-

... More
With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile confirming to ISO 5 (class 100) specifications

83.16

188972

2272.4

... More
Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge.

773.29

1004480

1298.97

... More
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.

426.39

126676

297.09

... More
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish

9682.67

816055

84.28

... More
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface

545.6

12068

22.12

... More
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade

6871.12

542887

79.01

... More
Applying priming coat with metal primer on new steel or iron work including preparation of surface.

517.03

13070

25.28

... More
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.

396.47

17960

45.3

... More
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.

396.47

11695

29.5

... More
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

1459.1

101451

69.53

... More
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm

1472.87

214125

145.38

... More
Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm

793.08

129502

163.29

... More
Construction of Plinth protection complete as per drawing.

-

-

-

... More
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.

18.7

3585

191.74

... More
Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type

7.48

30576

4087.72

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

26.93

150751

5597.92

... More
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material

58.95

32906

558.21

... More
Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).

88.42

35534

401.88

... More
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.

58.95

11752

199.37

... More
Construction of Sub Station cum Electrical Panel Room

-

-

-

... More
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.

324.01

62125

191.74

... More
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm.

325.89

127716

391.9

... More
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type

96.76

442609

4574.3

... More
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.

103.87

665925

6411.14

... More
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.

92.22

508564

5514.69

... More
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..

67.32

380965

5659.02

... More
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure.

192.03

147515

768.19

... More
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.

-

-

-

... More
Column

19.1

137544

7201.26

... More
Slab

53.73

386923

7201.26

... More
Beams

28.56

205667

7201.26

... More
Lintels

4.22

30389

7201.26

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

226.79

50175

221.24

... More
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.

443.27

248435

560.46

... More
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels

262.24

104982

400.33

... More
Centring and shuttering for columns (Square or rectangular or poly gonal in plain)

229.2

115177

502.52

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.

91.44

24275

265.48

... More
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend

20

2844

142.22

... More
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.

50

4424

88.49

... More
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.

20

2232

111.64

... More
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.

20

14916

745.8

... More
Providing and fixing in position gratings 150mm x 150mm on top Khura PVC grating

20

1757

87.87

... More
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing

413.59

318708

770.59

... More
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

90.22

6530

72.38

... More
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads.

411.68

214485

521

... More
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres

129.6

8601

66.37

... More
12.5mm thick cement plaster 1:5.

511.38

101953

199.37

... More
20 mm thick cement plaster 1:5 in two coats work.

511.38

139734

273.25

... More
12.5 mm thick cement plaster 1:4.

296.87

61689

207.8

... More
20mm thick cement plaster 1:4 in two coat work.

296.87

85183

286.94

... More
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

353.92

412097

1164.38

... More
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing

18.86

26688

1415.11

... More
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.

4233

552956

130.63

... More
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge.

7.43

8120

1092.87

... More
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete

-

-

-

... More
Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter.

30.94

16321

527.52

... More
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.

254.8

153894

603.98

... More
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items)

1712

249934

145.99

... More
Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects.

39.76

31624

795.39

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area

-

-

-

... More
Float glass panes of 5.5 mm thickness

79.52

50096

629.99

... More
Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect

260.9

15393

59

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.

12.84

138658

10798.95

... More
Providing and fixing ball bearing for push and pull type rolling shutters, from 9.20 to 12 sqm area

31.21

41329

1324.25

... More
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick

12.86

31255

2430.42

... More
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm

12.86

1503

116.94

... More
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm

6

1257

209.65

... More
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :

-

-

-

... More
For fixed portion and chawkhats

11.98

4442

370.83

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required

41.28

16003

387.69

... More
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge.

1.57

3919

2496.8

... More
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.

1.57

112

71.64

... More
Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).

38

15271

401.88

... More
Providing and fixing M.S. angle iron 40x40x4mm chowkhat including iron hold fasts butt hinges fixed in position, finished with red lead non setting primer complete in all respect

-

-

-

... More
For single rebate.

344.11

32263

93.76

... More
Iron grated doors, including pintle hinges and arrangements.

32.72

347826

10630.39

... More
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect

105

53206

506.73

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete

234.71

1848789

7876.91

... More
Extra rate for using steel produced in integrated plant from original ores complete in all respect as per the directions of Engineer-in-charge.

234.71

92304

393.27

... More
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.

393.24

116827

297.09

... More
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish

2009.75

169381

84.28

... More
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade

1416.01

111878

79.01

... More
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm

385.93

56106

145.38

... More
Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm

207.81

33933

163.29

... More
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.

28.94

1310

45.3

... More
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.

28.94

853

29.5

... More
Applying priming coat with metal primer on new steel or iron work including preparation of surface.

403.74

10206

25.28

... More
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

432.68

30084

69.53

... More
Total A2:-

-

-

-

... More
Dismentling of PP Unit

-

-

-

... More
Removing doors and windows together with the dismantling of walls

-

-

-

... More
Doors

33

4102

124.31

... More
Windows

39

3245

83.23

... More
Clerestory windows

41

3412

83.23

... More
Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.

827.51

95022

114.83

... More
Stripping and stacking slate or tiles of a roof.

732.91

33970

46.35

... More
Earth work excavation in ordinary soil, exclusive of compensation of earth:- Earth work undressed with a combined lead upto 15 metres including breaking of clods.

73.68

8460

114.83

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

650.25

3426

5.27

... More
Dismantling brick work tile, masonry or tile lining In cement

397.8

285815

718.49

... More
Dismantling concrete Reinforced cement concrete

150.04

348379

2321.91

... More
Stripping and stacking iron sheets of a roof including ridging, flashing, eaves boards gutters and down pipes.

124.82

3813

30.55

... More
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge

9.37

454

48.46

... More
Add for roof trusses of iron or wood, (rafters, purling etc.) in case of item Nos. 8.10 and 8.11.

125.36

7000

55.84

... More
Disposal of Malba ouitside the premises including loading and unloading as desired by Engineer in charge.

430.6

97371

226.13

... More
Total 1:-

-

-

-

... More
Credit of Material to be received from dismentling

-

-

-

... More
Tile from dismenling of tile terracing

16280

-65120

4

... More
Bricks from dismenling of Brick works

114720

-458880

4

... More
Brick/Tile bats

170.85

-90721

531

... More
Old Doors Complete set as fuel wood

33

-26400

800

... More
Old Window Complete set as fuel wood

39

-23400

600

... More
Old Ventilator Complete set as fuel wood

41

-8200

200

... More
PPGL Sheet

78.26

-15652

200

... More
ACC Sheet

35.77

-1788

50

... More
Fibre Sheet

11.33

-1133

100

... More
Credit of Steel & Iron

20733.84

-622015

30

... More
Credit of Sanitary Material such as HCI pipe floor trap & GI pipe etc.

5

-2500

500

... More
Credit of Electrical material such as aluminium/copper wire & other electrical fitting items

5

-2500

500

... More
Outer infrastructure

-

-

-

... More
Construction of Internal Approach Road, Parking & pavement/Footpath

-

-

-

... More
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications.

963.91

406635

421.86

... More
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type

228.34

1044495

4574.3

... More
Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with cement contents 350kg per cum and coarse and fine aggregates conforming to IS:383 mixed with concrete mixer using computerized concrete batch mixing plant including carriage by transit mixer with in 1km lead . , laid in position over 125 micron thick polythene sheet, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, including provision of contraction and expansion joints as required, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications

33.96

215577

6347.98

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

11.42

2526

221.24

... More
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. IS COde : 15658 (2006)

1276.17

894888

701.23

... More
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.

255.23

17478

68.48

... More
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)

27.87

53506

1919.87

... More
Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications

498.57

187806

376.69

... More
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material

341.92

190863

558.21

... More
Providing and laying 50 mm thick factory made cement concrete interlocking paver block of M-30 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt. ( Also not to used over footoaths).

341.92

226132

661.36

... More
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.

68.38

4682

68.48

... More
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior sufrace

224.36

4962

22.12

... More
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

224.36

15599

69.53

... More
PUBLIC HEALTH SERVICES

-

-

-

... More
Sub Work-1

-

-

-

... More
Sub Head-1 Internal Sewerage System

-

-

-

... More
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B

-

-

-

... More
110mm o/d single socket SWR UPVC pipe lines laid complete

281.62

111566

396.16

... More
75mm o/d single socket SWR UPVC pipe lines laid complete

270.95

83132

306.82

... More
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.

-

-

-

... More
qty as per Table Table-1

-

-

-

... More
For 110mm o/d pipes

-

-

-

... More
Elbow 90 Degree (All side socketed)

26

4226

162.57

... More
Vent Cowls

7

317

45.4

... More
Coupler

33

3665

111.09

... More
Single Tee With Door

9

2126

236.32

... More
For 75mm o/d pipes

-

-

-

... More
Elbow 90 degree (all side socket)

7

522

74.71

... More
Vent Cowls

7

220

31.43

... More
Coupler

44

3287

74.71

... More
Single Tee With Door

15

2386

159.11

... More
Floor Trap 110mm x 75mm

-

-

-

... More
With 75mm i/d outlet deep seal at Ground Floor

21

6509

309.99

... More
With 75mm i/d outlet shallow seal at First Floor

-

-

-

... More
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)

-

-

-

... More
110mm o/d

455

46077

101.27

... More
90mm o/d

374

32055

85.71

... More
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.

-

-

-

... More
M.S. Holder bats clamps for 100mm i/d as per table-1

21

4560

217.18

... More
M.S. Holder bats clamps for 75mm i/d as per table-1

21

4259

202.84

... More
Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge.

112

77168

689

... More
Providing and fixing galvonised hanging clamp 100mm dia chimney type for PVC pipe, 12mm galvonised fully thread bar with nut bolt as per requirement at site & as desired by Engineer-in-Charge.

112

43792

391

... More
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.

-

-

-

... More
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm as per table-1

7

13510

1930.01

... More
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.

-

-

-

... More
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal

7

47462

6780.33

... More
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.

-

-

-

... More
uPVC Pipe 6 Kgf/cm2 50mm i/d as per table-1

33.83

6139

181.47

... More
Total Sub Head-1:-

-

-

-

... More
Sub Head-2 Internal Water Supply System

-

-

-

... More
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.

-

-

-

... More
CPVC SDR 11 Pipe & fitting 16mm o/d

118.87

22380

188.28

... More
SDR 11 CPVC pipes & fittings 20mm o/d

262.12

61123

233.19

... More
CPVC SDR 11 Pipe & fitting 25mm o/d

524.23

157814

301.04

... More
CPVC SDR 11 Pipe & fitting 50mm o/d

426.7

337502

790.96

... More
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm

-

-

-

... More
qty same as GI P 15mm i/d to 25 mm (Table-2)

262.12

19053

72.69

... More
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.

-

-

-

... More
Through wall 11.43 cm thick Detail as per Table-2

70

12349

176.42

... More
Through wall 22.86 cm thick Detail as per Table-2

70

17619

251.71

... More
Providing, fixing and jointing Cpvc Union Couplings with Upvc Pipes complete in all respect.

-

-

-

... More
20mm i/d Cpvc Union

39

5341

136.96

... More
25mm i/d Cpvc Union

39

6985

179.11

... More
50mm i/d Cpvc Union

15

6321

421.43

... More
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.

-

-

-

... More
Detail attached as per Table-2

-

-

-

... More
25mm i/d Brass Ball valves

8

4446

555.85

... More
40mm i/d Brass Ball valves

8

8811

1101.38

... More
Sub Head - 3 Sanitary Installation

-

-

-

... More
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Detail attached as per Table-3

14

70500

5035.73

... More
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect. Detail attached as per Table-3

17

176730

10395.94

... More
Providing and fixing in position Metropole flush valve push type 32mm size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect. Detail attached as per Table-3

17

58205

3423.88

... More
Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut Detail attached as per Table-3

31

11822

381.37

... More
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. Detail attached as per Table-3

31

2710

87.44

... More
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.

18

124226

6901.48

... More
Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm

18

88215

4900.88

... More
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.

-

-

-

... More
Size 49 cm dia (above counter round)

8

39695

4961.99

... More
Size 550 mm x 400 mm x 815mm

26

98991

3807.35

... More
Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.

26

55056

2117.54

... More
Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineer-in-charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect.

-

-

-

... More
Size 470mmx370mmx180mm

-

-

-

... More
Providing & fixing 15 mm C.P brass laboratory cock swan neck of approved make (to the approval of Engineer-in-charge ) complete in all respect.

-

-

-

... More
Laboratory cock swan neck One Way

-

-

-

... More
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut

126

15398

122.21

... More
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.

26

3095

119.05

... More
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.

-

-

-

... More
C.P. brass towel Rails size 15mm dia 610mm long

2

3242

1621.34

... More
C.P brass towel ring

26

24953

959.74

... More
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.

34

30195

888.1

... More
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.

-

-

-

... More
C.P. brass Bib cock long nose/ long body without flange

2

2429

1214.69

... More
C.P Brass bib cock foam flow without flange

31

29947

966.06

... More
Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge) complete in all respect (instead of Pillar tap in Lavatory Suites). Detail as per Table-3

34

24285

714.27

... More
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.

-

-

-

... More
C.P.brass 15mm Angle valve without flange

126

109643

870.19

... More
C.P.brass 15mm Concealed stop cock with flange

14

17757

1268.41

... More
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.

173

11482

66.37

... More
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long

173

19500

112.72

... More
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm)

34

42947

1263.15

... More
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:

-

-

-

... More
C.P. brass toilet roll holder with flap

31

36414

1174.65

... More
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs

31

11985

386.63

... More
Providing and fixing divertors of approved make (to the approval of Engineer-in-charge ) for bath and shower system complete in all respect.

8

42114

5264.34

... More
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.

23

11749

510.84

... More
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks

8000

91040

11.38

... More
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball

-

-

-

... More
Brass Ball Cock with rod and Plastic Ball 32mm i/d

4

6399

1599.98

... More
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.

-

-

-

... More
G.I. tank nipple 25mm i/d

4

795

198.82

... More
G.I. tank nipple 40mm i/d

4

1508

377.1

... More
Construction of Plateform complete as per specification & as desired by Enginer-in-charge

-

-

-

... More
For 2000 ltr Water Tank

4

38016

9504

... More
Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.

-

-

-

... More
35mm dia 900mm (36”) long

10

18330

1833.09

... More
35mm dia 1200mm (48”) long

10

28096

2809.68

... More
Foldable U Type 762mm long

10

66528

6652.85

... More
Sub Head-4 Flooring and Wall Tile

-

-

-

... More
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material

-

-

-

... More
Ground Floor

49.15

27436

558.21

... More
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material

-

-

-

... More
Total All Floor

100.33

22266

221.93

... More
Extra rate for First Floor

31.9

100

3.16

... More
Extra rate for Second Floor

35.27

222

6.32

... More
Extra rate for Third Floor

33.16

314

9.48

... More
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .

-

-

-

... More
Total All Floor

149.48

134859

902.19

... More
Extra rate for First Floor

31.9

100

3.16

... More
Extra rate for Second Floor

35.27

222

6.32

... More
Extra rate for Third Floor

33.16

314

9.48

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm).

10.25

5405

527.36

... More
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

-

-

-

... More
Total All Floor

538.77

488842

907.33

... More
Extra Rate for First Floor

111.93

353

3.16

... More
Extra Rate for Second Floor

127.14

803

6.32

... More
Extra Rate for Third Floor

115.7

1096

9.48

... More
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..

-

-

-

... More
Total All Floor

5.02

17379

3462.06

... More
Extra Rate for First Floor

2.51

7

3.16

... More
Extra Rate for Second Floor

2.51

15

6.32

... More
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)

4.88

915

187.52

... More
Sub Head -5 Water Coller & Air Conditioning

-

-

-

... More
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.

-

-

-

... More
Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer Detail as per Table-3

4

150363

37590.99

... More
Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 2 KVA

4

15410

3852.65

... More
Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.

4

53479

13369.97

... More
Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects

-

-

-

... More
As per detail attached in table

1

54688

54688

... More
Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Starwith 5.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects

3

232440

77480

... More
Providing laying hard soft copper concealing of copper pipes of dia 12.7mm od (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.

40

54640

1366

... More
Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 6 Kgf/cm2 40mm i/d

40

10434

260.87

... More
Providing UGSR 150000 ltr including pump house

-

-

-

... More
Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.

315.55

27591

87.44

... More
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type

31.85

146190

4589.96

... More
Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth including carriage

44.47

298689

6716.65

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

104.68

23159

221.24

... More
Reinforced cement concrete M-40 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth

-

-

-

... More
Beams

-

-

-

... More
Ground Floor

0.7

5040

7200.21

... More
Slab

-

-

-

... More
Ground Floor

14.37

103467

7200.21

... More
First Floor

3.53

25416

7200.21

... More
Extra rate for First Floor

3.53

673

190.68

... More
walls

37.59

270655

7200.21

... More
Extra rate for Smooth Surface of RCC

385.7

21618

56.05

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete

-

-

-

... More
Ground Floor

90.42

712230

7876.91

... More
First Floor

2.82

22212

7876.91

... More
Extra rate for First Floor

2.82

38

13.7

... More
Extra rate for using steel produced in integrated plant from original ores complete in all respect as per the directions of Engineer-in-charge.

93.24

36668

393.27

... More
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved.

-

-

-

... More
Ground Floor

364.08

170684

468.81

... More
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.

-

-

-

... More
Ground Floor

118.55

66442

560.46

... More
First Floor

29.12

16320

560.46

... More
Extra rate for First Floor

29.12

306

10.54

... More
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels

-

-

-

... More
Ground Floor

5.6

2241

400.33

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.

-

-

-

... More
Ground Floor

10.89

62544

5743.3

... More
First Floor

1.97

11314

5743.3

... More
Extra rate for First Floor

1.97

303

153.81

... More
12.5mm thick cement plaster 1:5.

44.16

8804

199.37

... More
12.5mm thick cement plaster 1:4.

70.33

14614

207.8

... More
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete

-

-

-

... More
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter

10.06

6076

603.98

... More
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items)

51

7445

145.99

... More
Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect

10.36

733

70.8

... More
Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects.

0.79

754

954.47

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.

0.26

2807

10798.95

... More
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area

1.58

995

629.99

... More
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-202 Part-I) 1999, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick

1.88

4569

2430.42

... More
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm

3.46

404

116.94

... More
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm

1

209

209.65

... More
Applying priming coat with metal primer on new steel or iron work including preparation of surface.

3.95

99

25.28

... More
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.

4.23

191

45.3

... More
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.

4.23

124

29.5

... More
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

8.18

568

69.53

... More
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm

114.48

16643

145.38

... More
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). R.C.C. Manhole cover 560mm i/d RCC man hole cover with frame as per ISI

2

3600

1800.43

... More
Foot Rest for Manhole. Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.

22

4843

220.18

... More
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material

-

-

-

... More
First Floor

16.09

3570

221.93

... More
Extra rate for First Floor

16.09

50

3.16

... More
Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).

20.83

8371

401.88

... More
20mm thick grey polished skirting or dado consisting of bottom layer of 16mm thick cement sand plaster 1.3 and finished 3mm thick topping of neat cement rubbed and polished including rounding of junction with floors.

10.42

6626

635.96

... More
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing

18.53

14363

775.13

... More
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

17.98

1301

72.36

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.

2.74

727

265.48

... More
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend

1

142

142.22

... More
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.

1

88

88.49

... More
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.

1

111

111.64

... More
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.

1

762

762.02

... More
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating

1

87

87.87

... More
Providing & installing,testing & commisioning of 1 no electrically driven Boosting Pump set of 5.00 BHP (KSB / crompton equilent make capable of delivering 80 LPM against a head of 40 mtr complete in all respect as per specifications

2

65370

32685

... More
Providing & fixing 2.50mm2 core cable to Submersible Pump complete in all respect as per specifications

50

5250

105

... More
Providing & installation of smart starter panel board of 5BHP complete in all respect.

1

5265

5265.94

... More
Total Total Sub Head-5:-

-

-

-

... More
Sub Head 2.2

-

-

-

... More
Estate Water Supply

-

-

-

... More
Providing stringing out provide ISI marked as per IS-4985 (ISI) marked with the prior approva Engineer-in-Charge) casting along the Trenches and laying the same in Trenches to correct allignment and gradients, cutting, jointing and testing including excavations complete including excavations as per specifications 100mm o/d PVC pipe of 10kg/sqm2

-

-

-

... More
PVC pipe 80mm o/d 10kg

118.05

69531

589

... More
PVC pipe 100mm o/d 10kg

51.36

42731

832

... More
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1 as per ISI

-

-

-

... More
80mm i/d Sluice Valves flanged

2

8861

4430.64

... More
100mm i/d Sluice Valves flanged

2

12033

6016.61

... More
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.

4

22359

5589.83

... More
Providing & fixing C.I indicating plates of size 100mm x 100mm for SV/FH including synthetic enammel paint & letters in white enamel paint , fixing in the ground with angle iron of size 25x25x5mm, 230mm height from ground including concrete block complete in all respect as directed by Enginner-in-Charge.

4

1008

252.2

... More
Providing, fixing and jointing Cast Iron surface box for Sluice valve, Air valve, Fire hydrant etc. including all carriages complete.

132

9501

71.98

... More
Total Sub Head 2.2

-

-

-

... More
Sub Work-3

-

-

-

... More
Sub Head-3.1

-

-

-

... More
Sub Head-1 Estate Sewerage

-

-

-

... More
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.

-

-

-

... More
110 mm o/d pipes

42

25167

599.23

... More
160 mm o/d pipes

127.61

159945

1253.39

... More
200 mm o/d pipes

176.18

346043

1964.15

... More
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.

-

-

-

... More
For depth exceeding 3.0 m but not exceeding 4.5 m B.G.L. For all classes of soil except rocky

263.8

31959

121.15

... More
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.

72.55

49902

687.83

... More
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard

-

-

-

... More
Inside size 90x150 cm

-

-

-

... More
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.

-

-

-

... More
For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky

29.62

3089

104.3

... More
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type

3.79

17395

4589.96

... More
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth

7.98

45478

5699.06

... More
Cement Concrete 1:2:4 with stone ballast or shingle.using concrete mixing volumetric type

1.56

8849

5672.74

... More
Floating coat of 1:5mm thick neat cement laid in one operation to the topping

6.75

206

30.55

... More
12.5 mm thick cement plaster 1:3

29.11

6355

218.34

... More
Cement rendering on plaster 1mm thick

29.11

2062

70.85

... More
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.

2.42

14864

6142.49

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete

1.94

15281

7876.91

... More
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design

25

5504

220.18

... More
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). RCC Man hole cover with Frame 560mm i/d RCC man hole cover with frame as per ISI

5

10229

2045.9

... More
Inside size 120x180 cm on 160mm dia pipe line

-

-

-

... More
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.

-

-

-

... More
For depth not exceeding 3.0 B.G.L. For all classes of soil except rocky

12.22

1274

104.3

... More
For depth exceeding 3.0 but not exceeding 4.50 B.G.L. For all classes of soil except rocky

47.72

5781

121.15

... More
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type

6.11

28044

4589.96

... More
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth

0.56

3191

5699.06

... More
Cement Concrete 1:2:4 with stone ballast or shingle.using concrete mixing volumetric type

1.2

6756

5630.61

... More
Floating coat of 1:5mm thick neat cement laid in one operation to the topping

15.12

461

30.55

... More
12.5 mm thick cement plaster 1:3

2.1

485

231.19

... More
Cement rendering on plaster 1mm thick

2.1

149

71.22

... More
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.

4.91

29961

6102.07

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete

3.93

26899

6844.59

... More
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design

56

12330

220.18

... More
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). RCC Man hole cover with Frame 560mm i/d RCC man hole cover with frame as per ISI

7

14321

2045.9

... More
Sub Work-4

-

-

-

... More
Roof Top Rain water Harvesting

-

-

-

... More
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.

-

-

-

... More
160mm o/d PVC pipe of 4 Kgf. / sqcm

132.08

89824

680.08

... More
110mm o/d PVC pipe of 4 Kgf. / sqcm

33

10866

329.28

... More
Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects.

-

-

-

... More
For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky

100.89

10522

104.3

... More
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.

2.77

1905

687.83

... More
Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge

11

119812

10892

... More
Construction of Haudi internal size 0.45mtr x 0.45mtr & 0.45mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x450 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-charge

33

143451

4347

... More
Construction of Rain water recharge well 3.00mtr dia with working depth 3.50mtr dia consisting of drilling bore 300mm dia 35mtr, supplying and lowering pvc perforated housing pipe 200 mm dia 10kgf/sqcm 50mtr sorrunded with filtermedia , galvanised stainer CI pipe Class LA 150mm i/d 4mtr duly plugged from top with bail plug, fixing MS clamp, MS socket, Well size 3.00 mtr internal dia, 4.00 mtr deep constructed with BB in 1:5 cement sand mortar,plastered from inside, RCC slab, filtered media in 3 Layers, 2Nos RCC Man hole cover conneted with collecting chamber size 1mtr x 1mtr x 1.20 mtr deep providing and fixing MS grating and all other relevent material required as per site complete in all respect as per drawing attached and entire satisfaction of the Engineer-in-charge . (Note :- Payment will be made as per CSR Based Rates Plus/Minus Quoted rates).

2

761892

380946

... More
Sub Work-5

-

-

-

... More
Fire Fighting Arrangements

-

-

-

... More
Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity

24

171604

7150.19

... More
Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity

24

70567

2940.3

... More
SITC of MS Pipe Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.

-

-

-

... More
25mm internal diameter

61

19150

313.95

... More
50mm internal diameter

107

73781

689.55

... More
65mm internal diameter

122

104951

860.26

... More
80mm internal diameter

122

127583

1045.77

... More
100mm internal diameter

94.48

143415

1517.95

... More
SITC of Butterfly valve Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.

-

-

-

... More
80 mm i/d for Yard Hydrants

8

21627

2703.42

... More
100 mm i/d for Internal Hydrants

8

27448

3431.04

... More
Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.

-

-

-

... More
100mm i/d check valve

8

37508

4688.57

... More
150mm i/d check valve

5

41511

8302.33

... More
Providing and fixing S.S Pressure Gauge complete as required complete in all respect.

-

-

-

... More
Dial diameter 100mm calibration 0-16 Kg

8

6477

809.63

... More
Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank).

-

-

-

... More
Four Way inlet connection

2

19487

9743.88

... More
Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects.

20

135691

6784.57

... More
Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.

10

20474

2047.45

... More
Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required.

10

47110

4711.09

... More
Supplying, Installation, Testing and Commissioning of Non-percolating flexible CP HOSE as per IS:8423 / 1994 ISI marked 63mm dia x 15 m long complete with instantaneous type gun-metal 63 mm dia male & female coupling (IS: 903) bound and riveted to hose pipes.

20

83944

4197.24

... More
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.

10

95320

9532.07

... More
Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect.

10

8489

848.96

... More
Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc.

-

-

-

... More
900 mm wide x 600 mm high x 500 mm deep Size (for Yard Hydrant)

-

-

-

... More
600 mm wide x 600 mm high x 300 mm deep Size - (for RRL Reel)

10

43243

4324.3

... More
Providing & fixing Fire Hydrants with jointing including all carriages complete. (without Fire Hydrant surface box) Size 80mm complete in all respect.

-

-

-

... More
C.I Fire Hydrants S.V. Type IS-909 for Internal Hydrants

10

125229

12522.99

... More
C.I Fire Hydrants 1S-908 for Yard Hydrants

-

-

-

... More
C.I Fire Hydrants Stand Post Type IS-908

-

-

-

... More
Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required

2

36687

18343.56

... More
Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all respect

2

7598

3799.27

... More
Supplying and Installation control valve C/W water motor gong complete with alarm Valve, constant trim, water motor bell, 2No. Pressure Gauge. All parts UL listed. complete in all respect.

-

-

-

... More
100 mm control valve

2

55687

27843.88

... More
Supplying an Fixing Pendant / Upright type sprinkler with quartzoid bulb, operating temperature 68 / 79 degree centigrade of 15 mm dia orifice sprinler head to approved by UL/SN

31

8330

268.72

... More
Supplying and Fixing Sidewall Sprinkler rated at 68 / 79degree centigrade, quartzoid bulb type, 15 mm dia orifice sprinler head to approved by UL/SN complete in all respect.

190

59093

311.02

... More
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1 as per IS

-

-

-

... More
150mm i/d Sluice Valves flanged

22

196111

8914.18

... More
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts.

-

-

-

... More
100mm internal diameter

30.71

74583

2428.64

... More
150mm internal diameter

247.05

870132

3522.09

... More
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.

163.05

17022

104.4

... More
XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-

-

-

-

... More
Overall size 16sq.mm (3Core) Armoured (Underground)

91

45297

497.78

... More
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks

20000

227600

11.38

... More
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball

-

-

-

... More
Brass Ball Cock with rod and Plastic Ball 32mm i/d

2

3199

1599.98

... More
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.

-

-

-

... More
G.I. tank nipple 40mm i/d

2

754

377.1

... More
Construction of Plateform complete as per specification & as desired by Enginer-in-charge

-

-

-

... More
For 10000 ltr Water Tank

2

26934

13467

... More
Jockey Pump Supply, installation, testing & Commissioning of pump in back pull out design having 50mm suction, 32mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 7.5KW/10 HP, 2900 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow: 10.8 m^3/hr(180 lpm)

2

231584

115792.31

... More
Diesel Engine Supply, installation, testing & Commissioning of pump model in back pull out design (end suction type) having 100mm suction, 80mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 37KW/50 HP, 2900 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow : 137 m^3/hr(2280 Ipm)

2

1183075

591537.78

... More
Electric Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED DIESEL ENGINE DRIVEN PUMPSET in back pull design having 125mm suction, 100mm delivery, CI casing, bronze impeller, C-40 shaft with gland packed arrangement coupled on common MS fabricated baseframe vertical water cooled diesel engine complete with 12 V battery start arrangement, air cleaner, exhaust silencer(without piping), fuel filter, developing 56 bhp at 2500 RPM. Engine with twin belt driven radiator and complete with engine starting panel, Battery & AVM pods. Total head : 60m Flow : 137 m^3/hr(2280 Ipm)

2

559905

279952.96

... More
Sprinkler Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED DIESEL ENGINE DRIVEN PUMPSET in back pull design having 125mm suction, 100mm delivery, CI casing, bronze impeller, C-40 shaft with gland packed arrangement coupled on common MS fabricated baseframe vertical water cooled diesel engine complete with 12 V battery start arrangement, air cleaner, exhaust silencer(without piping), fuel filter, developing 56 bhp at 2500 RPM. Engine with twin belt driven radiator and complete with engine starting panel, Battery & AVM pods. Total head : 60m Flow : 1620 Ipm

2

559905

279952.96

... More
Hydrant Panel Providing & fixing of Hydrant Electrical Panel of cubical type floor mounted power cum control of Jockey Pump 1 No. & Electrical Pump 2 No. having MCCB 400 Amp 3 Pole 36 KA, MCCB 180 Amp 3 Pole Contactor 110 Amp. Contactor 180 Amp Realy 66-110, Realy 14-23,SSP ,SP,MCCB 63 Amp, 3 Pole, Digital Meter Set, Hardware, Aluminium Bus bar Set, Wire & Thimble, Panel Box 16 Gouge. Complete in all respect.

1

42145

42145.91

... More
Sub Work-6

-

-

-

... More
PART A : EQUIPMENTS

-

-

-

... More
Air Cooled Chilling Machine

-

-

-

... More
Air Cooled Chilling Units

-

-

-

... More
Air cooled chilling machine, Supply, Installation, testing & commissioning of 40 TR (-3%)actual capacity air cooled Inverter scroll Chilling Machines fitted with hermetically sealed lnvertor scroll compressors, multi/single circuit chiller, Air cooled shell & tube condenser, Microprocessor based BMS Compitable control panel, suitable for R- 410a ecofriendly Refrigerant, Shell & Tube Insulated Evaporator, Expansion tank of suitable capacity Control Mechanism of actual Cooling capacity . The unit shall confirm to ECBC norms and shall be factory tested as per AHRI standard 550/590 latest edition.

-

-

-

... More
The chilled water type AC plant will be suitable for operation on 3 phase AC 50 Hz supply .

-

-

-

... More
The chiller shall be as per specifications. The water chilling machine shall meet the following design parameters

-

-

-

... More
Chilled Water leaving Temp. :44 Deg F

-

-

-

... More
Chilled Water entering Temp. :54 Deg F

-

-

-

... More
Evaporator fouling factor : 0.000500 h.ft2.ºF/Btu

-

-

-

... More
Ambient Temperature : 43º C

-

-

-

... More
COP at 100% Load: 3.2 at AHRI Conditions

-

-

-

... More
Minimum IPLV = 0.8 kW/tonR

-

-

-

... More
Water flow switches at outlet of chiller, water drain, air purge valves, thermometers and pressure gauges etc as required.

-

-

-

... More
Frame work for mounting the above condenser, fans, chiller compressor and motor with base plate complete with antivibration pads/springs complete etc as required.

-

-

-

... More
Initial / first charge of refrigerant gas, lubricating oil and compressor oil etc as required.

-

-

-

... More
The chiller shall be BMS compatible.

-

-

-

... More
Suitable RCC/Cement concrete foundations with MS angle nosing all around, for the chilling unit installation complete etc as required.

-

-

-

... More
Dial type 6', SS tubing with valves thermometers and pressure gauges at inlet and outlet of chiller complete etc as required.

-

-

-

... More
Min. 40TR (-3%) Actual capacity. Water chilling machine as described above and at above mentioned operating conditions.

-

-

-

... More
Note :

-

-

-

... More
The price should include all clearance charges , unloading and shipment till site Including Insurance Charges ,Unloading at site, placement of Chilling machine on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned chiller.

2

2870088

1435044

... More
Note: i)The cost of RCC foundations will be included in chiller machine price and shall be made by the tenderer. ii) In case manufacturer does not have single chillermachine of 40 TR then they can provide 2 nos of machines to fullfill the 40 TR requirment

-

-

-

... More
PUMPS

-

-

-

... More
Primary constant chilled water pump

-

-

-

... More
Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. Casing (Volute) - Cast Iron. Impeller - Gunmetal Bronze - Statically and Dynamically Balanced Casing Gasket - Confined Non Asbestos Fiber Pump Shaft - SS 416. Flush Line - Braided Stainless Steel Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) with external flushline. Motor Type - TEFC Squirrel Cage, Efficiency Class - IE3, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply

-

-

-

... More
Chiller Water Pump Water Flow Rate: 96 USGPM Head : 15 m WC

2

206970

103485

... More
Lot - Expended Polystyrene (TF quantity) insulation not less than 75mm thick duly cladded between aluminium sheets of 0.63mm thickness and properly clamped to pump in two semicircular sections as per specifications.

-

-

-

... More
Pump as above

-

-

-

... More
Note: The civil foundations reqd shall be made by the tenderer.

-

-

-

... More
Secondary Chilled water pump ( with VFD )

-

-

-

... More
Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. Casing (Volute) - Ductile Iron. Impeller - 316 SS - Statically and Dynamically Balanced Casing Gasket - Confined Non Asbestos Fiber Pump Shaft - 316 SS . Flush Line - Braided Stainless Steel Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) with external flushline. Motor Type - TEFC Squirrel Cage, Efficiency Class - IE5, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply VFD - Integrated motor mounted over Pump with IP- 55 protection. pump should operate through sensorless control or wireless DPT control. Pump Efficiency should be more than 75% Integrated fliter to meet EN61800-3 for RFI Control, Integrated DC link Reactor equivalent in performance to a 5% AC line reactor. All the VFD should display the dynamic head & flow rate of the pump using inputs from ultrasonic flow meter and digital pressure gauge or using sensorless alogorithms,( 1 flow meter and 2 pressure gauges to be supplied for each VFD driven pump). Pump manufacturer to supply Ultrasonic flow meter and digital pressure gauges along with the pumps supplied or can display individual flow and head of each pump using sensorless alogorithms. Pump Manager to assure performance manangment till DLP should be supplied for all VFD driven pump along with mode/Router for cloud connectivity without dependency on BMS.

-

-

-

... More
Chilled Water Pump ( 1W+1S ) with integrated VFD (For Variable primary system) Water Flow Rate: 196 USGPM Head : 25 m WC

2

524128

262064

... More
Lot - Expended Polystyrene (TF quantity) insulation not less than 75mm thick duly cladded between aluminium sheets of 0.63mm thickness and properly clamped to pump in two semicircular sections as per specifications.

-

-

-

... More
Pump as above (1 working + 1stand by)

-

-

-

... More
Note: The civil foundations reqd shall be made by the tenderer.

-

-

-

... More
Hot Water Generator

-

-

-

... More
SITC of Electric hot water generators of following capacities vertical tubular shell type fabricated from MS sheet 6mm Shell 8mm Dish ends, Top open able with sufficient number of Nut Bolts and joints shall be welded and shall be tested for working pressure of 21 kg/cm² complete with sheathed tubular electric resistance type heater elements , control panel with contactor, internal, wiring, safety controls, thermostat, IN and OUT connections, drain connection at the bottom, water flow switch and interlocking with control panel, Step Controller, Pressure Gauges with Ball Valves, Pressure relief Valve, Low Level cutout and Auto vent. It shall be insulated with 50 mm thick fiber insulation and covered with 1 mm thick Aluminium cladding.

-

-

-

... More
Note: The civil foundations reqd shall be made by the tenderer.

-

-

-

... More
72 KW ( with multiple Steps)

1

237992

237992

... More
AIR HANDLING UNITS FOR OT'S

-

-

-

... More
Supplying, installing, testing and commissioning of Floor Mounted double skin type air handling units with thermal break profile made of Min .48+-2 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.8 mm outside layer and Aluminium sheet of thickness 0.8mm inside layer with polyurethene foam (PUF) CFC Free insulation of density 40+-2 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW backward curved centrifugal fan of 125 mm WC static pressure for FM AHU's, 8 row deep cooling, section with hydrophillic aluminium finned copper tubes (tube thickness not less than 0.5mm), Filter section with 50 mm thick flange type pre filter & MERV-13 fine filter on Suction or as per site requirement. , belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply,Mixing box with Aluminium Anodised Extruded dampers at fresh and return air cutouts, drain connections with drain valve, stainless steel drain pan,Light , thermometers and pressure gauge at the inlet and outlet of cooling coil, necessary vibration isolation arrangement etc, complete as per specifications of following capacity :(AHU Design/Air Flow must be according to HEPA Filters for OTs, As these Hepa Filters to be put in supply Air Duct or at Terminal)

-

-

-

... More
Hardware for hanging of AHU with GI thread rods, check nuts/washers

-

-

-

... More
PAN type Humidifier: Thyrister Based Pan Type Humidifier for Humidification of dry ambient along with its all connecting wires for FM AHUs

-

-

-

... More
Variable Frequency drive for AHU motor to run it on min 25% rpm whenever area is non functional for OT AHU only (Can be provided in AHU Panel also)

-

-

-

... More
CFM TYPE SP CC /TR

-

-

-

... More
3500 FM 125 8 RD /10.0

1

249315

249315

... More
5200 FM 125 6 RD /15.0

1

362592

362592

... More
AIR HANDLING UNITS CEILING SUSPENDED

-

-

-

... More
Supplying, installing, testing and commissioning of factory built weather Proof Ceiling Suspended double skin type air handling units with thermal break profile made of Min 32 +-2 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.6 mm outside layer and sheet of thickness 0.6mm inside layer with polyurethene foam (PUF) CFC Free insulation of density 40+-2 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW backward/Forward curved centrifugal fan for CS AHU's, 6 row deep cooling coil, section with aluminium finned copper tubes (tube thickness not less than 0.5mm), Filter section with 50 mm thick box type pre filter & microvee filter on common frame. , belt/Direct drive package with TEFC drive motor(IE-3) suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply,Mixing box with Aluminium Anodised Extruded dampers at fresh and return air cutouts.,drain connections with drain valve, stainless steel drain pan, thermometers and pressure gauge at the inlet and outlet of cooling coil, necessary vibration isolation arrangement etc, complete as per specifications of following capacity:

-

-

-

... More
Hardware for hanging of AHU with GI thread rods, check nuts/washers

-

-

-

... More
CFM TYPE SP CC /TR

-

-

-

... More
6000 CS/FM 70 6.0 RD /15.0

1

327913

327913

... More
4400 CS 70 6.0 RD /12.0

1

269062

269062

... More
3000 CS 65 6.0 RD /10.0

1

194063

194063

... More
2800 CS 65 6.0 RD /8.0

1

186184

186184

... More
2000 CS 65 6.0 RD /6.0

1

141146

141146

... More
FCU

-

-

-

... More
SITC of Double Skin FCUs having CHW cooling coil with UVGI Mounted,pre filters complete with Ball valve assy, 2-way control valves, Thermostat, wiring,fittings, Aux. Drain tray, pipe insulation, hanging arrangements etc. Fan coil units shall be suitable for operation on 220 +6% Volts, 50Hz, single phase power supply complete in all respects of cap:-

-

-

-

... More
2.0 TR

1

29377

29377

... More
AHU For Exhaust

-

-

-

... More
Supplying, installing, testing and commissioning of factory built Floor Mounted/Ceiling suspended double skin weather Proof type air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.6 mm outside layer and plane GI of 0.6mm inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW backward/Forward curved centrifugal fan, belt drive package with TEFC drive motor suitable for VFD & 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with canvass connections ,necessary vibration isolation arrangement etc, complete as per specifications of following capacity

-

-

-

... More
400 CFM 75 mm Static with Hepa Filter(H-13) of 99.77% to 3 Micron & Micro Vee Filters at discharge and Pre Filters with MERV 8

1

95232

95232

... More
900 CFM 75 mm Static with Hepa Filter(H-13) of 99.77% to 3 Micron & Micro Vee Filters at discharge and Pre Filters with MERV 8

1

95232

95232

... More
1100 CFM 45 mm Static with Min MERV 7 Pre filter sections and MERV 14 Fine filters at discharge )

1

64688

64688

... More
Duct mounted Electric Air Heater Unit for Reheating

-

-

-

... More
Supply, installation, testing and commissioning of Flanged type duct mounted non‐flameproof Electric Air Heater Unit made out of 0.8mm thick GPSP sheet having 30mm flange and duly insulated with fiberglass wool to minimize heat loss. AISI 304 stainless steel Electric tubular heaters without fins having low watt density are provided with support brackets. The unit shall be equipped with safeties such as adjustable type primary thermostat, KLIXON® secondary thermostat manual reset type and Air flow switch to prevent the heater from operating without airflow. It shall be provided with an inbuilt control panel having suitable rating incomer MCB, ON/Trip indication light, contactor, Thyristor module to operate 0‐100% as per demand, terminal for AHU/Blower interlock, grounding terminal, power and control wiring. The unit shall be BMS compatible. Three Phase Wiring and The unit shall be CE certified.

-

-

-

... More
3.0 KW

1

62221

62221

... More
PART B : LOW SIDE WORK

-

-

-

... More
CHILLED WATER PIPING

-

-

-

... More
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.

-

-

-

... More
Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.

-

-

-

... More
125 MM Pipe DIA

12

18912

1576

... More
100 MM Pipe DIA

80

101120

1264

... More
80 MM Pipe DIA

70

63490

907

... More
65 MM MM Pipe DIA

15

11130

742

... More
50 MM MM Pipe DIA

25

14650

586

... More
40 MM MM Pipe DIA

25

10900

436

... More
32 MM MM Pipe DIA

15

5490

366

... More
25 MM Pipe DIA

12

3468

289

... More
INSULATION

-

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.

-

-

-

... More
Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.

-

-

-

... More
For 125 MM Pipe DIA with 75 mm Thick Insulation

12

14352

1196

... More
For 100 MM Pipe DIA with 50 mm Thick Insulation

80

63440

793

... More
For 80 MM Pipe DIA with 50 mm Thick Insulation

70

43960

628

... More
For 65 MM Pipe DIA with 50 mm Thick Insulation

15

8145

543

... More
For 50 MM Pipe DIA with 50 mm Thick Insulation

25

11225

449

... More
For 40 MM Pipe DIA with 50 mm Thick Insulation

25

9100

364

... More
For 32 MM Pipe DIA with 50 mm Thick Insulation

15

4845

323

... More
For 25 MM Pipe DIA with 50 mm Thick Insulation

12

3300

275

... More
SITC of INSULATED VALVES /CONTROLS - PN-16 (Insulated material should be same as on MS chilled water pipes)

-

-

-

... More
SITC with insulation Wafer Type C.I. Butterfly Valves(Manual) with Nylon Coated,Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified,SS-stem with Hand Lever Fittings like Flanges, Nuts & bolts, etc.

-

-

-

... More
125 MM DIA

2

18102

9051

... More
100 MM DIA

4

26912

6728

... More
80 MM DIA

4

21756

5439

... More
65 MM DIA

2

8942

4471

... More
50 MM DIA

6

24972

4162

... More
Supplying, fixing, testing and commissioning of duly insulated Balancing Valves with rating PN16

-

-

-

... More
100 MM DIA

1

17338

17338

... More
80 MM DIA

2

23938

11969

... More
65 MM DIA

1

10559

10559

... More
50 MM DIA

2

18300

9150

... More
AIR SEPARATOR

-

-

-

... More
Supply,installation,testing and commissioning of Microbubble Air & Dirt Separator, with matching flanges, bolts, nuts & gasket, PN16 complete with flanged connection and as per the specifications as detailed earlier in the relevant section of specifications , and duly insulated with 50 mm thick TFF expanded polysterene and cladded with 26G aluminum sheet.

-

-

-

... More
125 mm Dia Air Separator , duly insulated.

1

70994

70994

... More
SITC Y - Strainer-with actual bore size & double strainer size duly insulated suitable for PN-16

-

-

-

... More
100 MM DIA

1

27630

27630

... More
80 MM DIA

4

60356

15089

... More
50 MM DIA

2

19346

9673

... More
SITC Dual Plate Type Wafer Swing Check Valves duly insulated Cast Iron to IS 210 Gr. FG 260 with Fittings like Flanges, Gaskets, Nuts &bolts, etc.

-

-

-

... More
100 MM-DIA

2

17658

8829

... More
80 MM DIA

2

37382

18691

... More
SITC of Forged Brass Ball valves with & without strainers

-

-

-

... More
along with all required fittings etc.of sizes:

-

-

-

... More
25 mm without strainer

1

995

995

... More
25 mm with strainer

1

3030

3030

... More
32 mm without strainer

1

1626

1626

... More
32 mm with strainer

1

4668

4668

... More
40 mm without strainer

1

2328

2328

... More
40 mm with strainer

1

7009

7009

... More
SITC Water Flow Switchs

4

6196

1549

... More
SITC Auto Air Purging Valve 3/4"

6

13602

2267

... More
SITC Pressure Gauge 4" Dial (0 To 6 Kg/CM2)

4

5204

1301

... More
SITC 6" StemType Thermometers (0 To +50OC)

4

2228

557

... More
SITC of 2 - Way Mixing Valves with Actuator, Linkage, RH +Temperature Controller, Sensors, Control wires, Thermostat and Necessary Fittings etc. as per Following Sizes

-

-

-

... More
50 mm dia

1

26650

26650

... More
40 mm dia

1

18493

18493

... More
25 mm dia

1

16656

16656

... More
RH & T Sensors

-

-

-

... More
Supply Installation, Testing & Commissioning of Room Type Temprature Sensor with Range 0-50 Deg C (resistance Output)+ RH with Range 0-100RH Transmitter with active 0-10V outputs for both T & RH. ( RH Accuracy ±3% )

2

40470

20235

... More
Air Differential pressure sensor and adjuster package

-

-

-

... More
Supply, install , test and commission room differential pressure sensor and remote adjuster package for varying the speed of the exhaust fan-(by providing command to the variable frequency drive of the exhaust fan),to maintain the desirable positive / negative the pressure relationship of the isolation rooms with respect to the adjascent areas.

-

-

-

... More
Air Differential pressure sensor and adjuster package as described above

2

25316

12658

... More
Aluminium Ducting (Rectangular)

-

-

-

... More
SITC of Factory/SITE fabricated Aluminium Ducting complete with hanging arrangement of fasteners, GI threaded rods etc.,However Bends,Vanes,Collor can be can be made at site as per requirment

-

-

-

... More
0.8 mm (22 G)

30

50610

1687

... More
1.0 mm (20 G)

50

102200

2044

... More
Ducting

-

-

-

... More
SITC of Factory fabricated GSS Ducting complete with hanging arrangement of fasteners, GI threaded rods etc.,However Bends,Vanes,Collor can be can be made at site as per requirment

-

-

-

... More
24 G (0.63 MM)

105

108990

1038

... More
22 G (0.80 MM)

65

75660

1164

... More
20 G (1.00 MM)

5

6450

1290

... More
Nitrile Insulation (Inside Conditions)

-

-

-

... More
SITC of UL approved thermal insulation on AC ducts with closed cell nitrile rubber insulation of class ‘O’ Fire rating conforming to BS 476 Part 6 including providing adhesive, adhesive tapes etc. as per specifications. (for indoor ducts only)

-

-

-

... More
9 MM Thick

260

120640

464

... More
SITC of Acoustic lining of the supply duct with 10 mm thick Accosound Nitrile board with suitable adhesive to be pasted inside of the Plenum duct complete in all respects

-

-

-

... More
10 mm thickness accosound Board

10

11250

1125

... More
HEPA Filters

-

-

-

... More
Providing and fixing of HEPA Filters(H-13 or Equivalent) Having efficiency 99.97%down to 3 Micron in supply Air Duct of following Sizes

-

-

-

... More
600(L)X 600 (W)X 300 (D) or Suitable Size as Per Site Requirment (Note: Qty may Increase or Decrease)

1

17856

17856

... More
HEPA Filters & OT Plenum for Laminar Flow

-

-

-

... More
SITC of Aluminium white epoxy powder coated or SS 304 Factory Fabricated O.T. PLENUM (Aprox.size 8'x6') & HEPA Filters Having efficiency 99.97%down to 3 Micron ,I.P.D 15 mm HG & F.P.D. = 50 mm HG, The Hight of OT Plenum should not be more than 400 mm

1

339359

339359

... More
Grill/Diffussers

-

-

-

... More
SITC of Aluminium extruded powder coated Grills for supply & return air w/o vcd

7

29505

4215

... More
SITC of Aluminium powder coated Diffuser with removable core for supply & return air w/o vcd

1

10125

10125

... More
Dampers

-

-

-

... More
Supply, installation, testing & commissioning of Al Collar dampers

2

8416

4208

... More
Supply, installation, testing & commissioning of CBRI approved Fire duct Dampers for at least 90 min fire rating as per UL555:1955 Specifications without Sleeve

2

15068

7534

... More
Supply, installation, testing & commissioning of Spring Return Actuator and Control Panel Complete with Heat Sensors , Complete Control wiring and Limit switch,4NM/7NM/9NM,(24VAC/220VAC)

2

21392

10696

... More
Fresh Air Louvers

-

-

-

... More
SITC of Extruded aluminium exhaust air / fresh air louvres with frame, bird screen, pre-filter with frame, mounting arrangement etc. as per specifications and drawing.

-

-

-

... More
Fresh Air / Exhaust air Louvers

0.5

2981

5962

... More
Condensate Drain Piping:

-

-

-

... More
Providing UPVC pipes of various sizes for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/consultant/Client

-

-

-

... More
All necessary civil works like cutting & chasing of walls/floor/ glass etc. and make them good thereof

-

-

-

... More
40 MM DIA with 6 mm Nitrile Insulation

50

10800

216

... More
32 MM DIA with 6 mm Nitrile Insulation

100

16400

164

... More
25 MM DIA with 6 mm Nitrile Insulation

30

3660

122

... More
PART-C : Electrical Work

-

-

-

... More
Power & Control Works

-

-

-

... More
Supplying and laying of following 1100 volt grade PVC insulated sheathed copper conductor armoured cables in trenches, on walls clamped to wall with suitable clamps, saddles, and fixing bolts, or laying in ground including cost of digging brick and sand protection, and including jointing / connecting / terminating, testing and commissioning :

-

-

-

... More
3.5C x 95 Sq. mm Aluminium (armoured) Conductor Per run

20

18880

944

... More
3.5C x 50 Sq. mm Aluminium (armoured) Conductor

10

5580

558

... More
3.5C x 35 Sq. mm Aluminium (armoured) Conductor

10

4170

417

... More
4C x 10Sq. mm mm Aluminium (armoured) Conductor

10

2450

245

... More
4C x 4.0Sq. mm Copper (armoured) Conductor

20

8760

438

... More
4C x 2.5 Sq. mm Copper (armoured) Conductor

10

3110

311

... More
8C x 1.5 Sq. mm Copper (armoured) Conductor

10

4220

422

... More
Control Cabling

-

-

-

... More
Providing & fixing of electrical supply Flexible Cabling of 4 core x 2.5 sq. mm copper

15

2475

165

... More
Providing & fixing control cum transmission wiring/ Control Cabling of 4 core x 1.5sq. mm copper in suitable conduits for Actuator/Motor , Fire Dampers Control Dampers

10

1010

101

... More
1.5 MM² X 2 C CU for Controls/Interlocking with saddles etc

10

540

54

... More
(Make : Havell's,Eko,Gloster,Finolex,Polycab/KEI)

-

-

-

... More
Main Electrical Panel

1

367533

367533

... More
Main Electrical Panel (CPRI Approved OEM at least 70K)

-

-

-

... More
SITC of Electrical Main Panel Powder Coated Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make sheet having thickness 2.0 mm for load bearing surfaces & 1.6 mm Non bearing surfaces as per following specifications complete in all respect

-

-

-

... More
INCOMING SUPPLY : MCCB 500-630 Amps 50 KA 4 Pole Adjustable type with Rotary Mechanism & all Protections along with spreader links,etc : 1 No.

-

-

-

... More
Multi Fuction VAF/VIF Meter (96mmX96mm Size) ,Indication Lamps LED Type RYB, Control MCB SP for Control (3 Nos),CT's 600/5 (3 Nos) and Control Terminal (8.0 Nos.) etc.

-

-

-

... More
OUTGOING FEEDERS :MCCB 200-250 AMPs 36KA 3 Pole with Rotary Mechnism & all Protections along with spreader links,etc. : 3 Nos .(Chiller-2 W +1S).) with electrical interlocking provisioning

-

-

-

... More
MCCB 160-200 Amps 36 KA 3 Pole with Rotary Mechanism & all protections alongwith Spreader links, etc : 2 Nos ( HWG-1W+1S) with electrical interlocking provisioning

-

-

-

... More
3 Nos. Primary CHWP : 32 Amp TP MCCB with Rotary Mechanism and Spreader Links outgoing for 5 KW (Approx) CHWP & 5 KW Dol starter along with auto mannual selection switch , On off Push Button & Indicating Light . Primary CHWP x 3 No.(2W+1S)

-

-

-

... More
2 Nos. Secondary CHWP : Upto 63 Amp TP MCCB with Rotary Mechanism and Spreader Links outgoing for 7.5 -10KW (Approx) CHWP & 7.5-10KW Dol starter /Star delta along with auto mannual selection switch , On off Push Button & Indicating Light . Secondary CHWP x 2 No.(1W+1S)

-

-

-

... More
MCB TPN Upto 20 Amps :2 Nos

-

-

-

... More
MCB TPN Upto 63 Amps : 2 Nos

-

-

-

... More
BUS BAR : Aluminium Bus Bar 600 A TPN Electrolite grade E91 having Suitable size Cross Section for Phase,Neutral& Current Carrying Capacity 0.8 A/Sqmm

-

-

-

... More
Hardware ( PVC  Cahnnels/MCB Channels/Fibre- Glass  Gaskets/Sleevs/nuts/bolt/washers/cooling fans etc Including complete wiring,thimbles etc.

-

-

-

... More
Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel.

-

-

-

... More
Switch Gear Make :Siemens/ABB/Schneider

-

-

-

... More
Panel Make : ABB/Siemens/L&T/Schiender/Vrindavan Electricals/Unitech Power System

-

-

-

... More
AHU Panels for upto 7.5HP DOL type Starter

-

-

-

... More
SITC of AHU panels duly powder coated wall mounted Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make CRCA Sheet of 1.6 mm thick consisting of Upto incomer as MPCB suitable as per AHU

-

-

-

... More
ON/OFF/TRIP indication light LED type, DIGITAL Ammeter with ASS; CT's 30/5; contactors up to32A or Suitable (with 2 NO+ 2NC); Start/Stop push buttons with auto & Manual control switch, Single Phase Preventer, MCB DP upto 10 Amps C Curve ,Over load Relay 16-25A or Equivalent Suitable , power & control terminals; neutral link and internal wiring & connections for AHU motors upto 7.5 HP or Suitable alongwith dehumidfier control , In case of exhaust dehumidifier control is not required

1

30146

30146

... More
Panel Make : ABB/Siemens/L&TUnitech Power System/Vrindavan Electricals

-

-

-

... More
AHU Panel for upto 7.5KW with VFD & bypass with DOL Type Starter

-

-

-

... More
SITC of AHU panels duly powder coated wall mounted Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make CRCA Sheet of 1.6 mm thick consisting of Upto incomer as MPCB suitable as per AHU with VFD

-

-

-

... More
VFD suitable for AHU alongwith bypass DOL starter consisting of the following: ON/OFF/TRIP indication light LED type, DIGITAL Ammeter with ASS; CT's 30/5; contactors up to32A or Suitable (with 2 NO+ 2NC); Start/Stop push buttons with auto & Manual control switch, Single Phase Preventer, MCB DP upto 10 Amps C Curve ,Over load Relay 16-25A or Equivalent Suitable , power & control terminals; neutral link and internal wiring & connections for AHU motors upto 10 HP or Suitable alongwith dehumidfier control ,In case of exhaust dehumidifier control is not required

1

59796

59796

... More
Panel Make : ABB/Siemens/L&TUnitech Power System/Vrindavan Electricals

-

-

-

... More
Control Console Panel

-

-

-

... More
Suuplying, Installation, Testing & Commissioning of floor mounted desk type Control Consiole in A/c plant room containing various indications and controls for the A.C. system comprising of 3 Nos. chilling machine, 4 Nos. pumps, tower, 15 Nos AHU/CSU with test push buttons facility along with 5Nos Spare. The panel shall be fabricated from minimum 1.633 thick M.S. Powder coated sheet of approved design. The A.C. module of the Central Control shall have the following accessories:

-

-

-

... More
Status indication (ON, OFF) for each compressor for each chilling machine and all pumps.

-

-

-

... More
Push Buttons & Indication lamps for remote start & stop and status indication for each of the AHUs.

-

-

-

... More
Push Buttons & Indication lamps for remote start & stop and status indication(ON, OFF & Fault) for Cooling Tower motors and low level indication for cooling tower.

-

-

-

... More
Hooter & Flashing lamps to indicate operation of any safety/shut down with necessary contractors, accept, reset and test push buttons complete as per specifications.

1

171791

171791

... More
Panel Make : ABB/Siemens/L&TUnitech Power System/Vrindavan Electricals

-

-

-

... More
Earthing

-

-

-

... More
Providing, Installation, Testing & Commisioning Earthing station with copper plates , copper strips and copper wire complete in all respects as per ISI specifications.

1

21680

21680

... More
SITC of GI 8 SWG wire earthing complete with thimbles etc

40

2120

53

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required

1

15899

15899

... More
(Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

10

1300

130

... More
Cable Tray

-

-

-

... More
Providing and fixing of perforated type GI Cable Tray (1.6 mm thick) for Running Copper Refrigerant Piping of of Following Sizes including nut bolts G.I Thread rods Complte in all Respect

-

-

-

... More
50mm x 450mm x 50 mm.

20

11180

559

... More
50mm x 300mm x 50 mm.

20

8580

429

... More
50mm x 150mm x 50 mm.

40

12000

300

... More
Expansion Tank ,

-

-

-

... More
SITC of MS Expansion tank of size 1.0 m x 1.0 m x 1.0 m height made of 3 mm thick MS sheet complete with vent and drain connection, quick fill with float valve and control valve etc. as required. Litres duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete in all respect

1

21259

21259

... More
AOP cell with NANOX & PLASMAOX technology & Bi Polar Ionizer.

-

-

-

... More
SITC of Advanced Oxidation Pentplasma (AOP) cells comprising of UVC lamp 254 NM on NANO metallic compound target Alumninum matrix cell duly enclosed by a poly casing tube, with the capability to produce plasma Hydroxyl oxidizers along with anti microbial coating (EPA Approved). The unit shall have inbuilt multipin ion generator (+-10^6) pins along with ultrasonic radio frequency waves for pest repellancy. The UV-C lamp will be a low-pressure mercury type and of such intensity as to provide minimum performance as listed below. The UV-C lamp will produce only Germicidal UV (by definition this means 99.99% UV-C energy).The cell will have built in LED indication system stating the operation of the 3 technologies the UV lamp, ionizer and pest repellant. The power / control cabling between the Pentagon units and the power source / controls shall be included in the cost .The system shall be capable of reducing microbial bacteria, Covid 19 virus,virus and spores , VoC’, odors and particulates matter. The equipment shall conform to CE and ROHS. Standards certifications shall be submitted along with the technical submital. The Pentagon cells should be selected by considering a load factor calculation for each specific area where the equipment is to be installed. The wattage shall not be less than mentioned. The AOP/ Pentagon Cells Should be complete with Transformers, control cabling and Plug Top & necessary power cable.

-

-

-

... More
Duct Mounted AOP with UVC Lamp System for following Air Flow's

-

-

-

... More
Upto 6500 CFM

1

81123

81123

... More
Grand Total (Part A+B+C)

-

-

-

... More
Total Sub Work 1+2+3+4+5+6:-

-

-

-

... More
ELECTRICAL ESTIMATE

-

-

-

... More
Providing Internal Electrical Installations:

-

-

-

... More
POINT WIRING:

-

-

-

... More
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring fan point with sheet metal fan box

84

101657

1210.21

... More
Wiring light point

668

509329

762.47

... More
Wiring call-bell point

1

744

744.03

... More
Wiring 3 pin 6 Amp. wall socket point

95

58798

618.93

... More
Wiring 3 Pin 6 Amp. Plug control comprising wall socket point

67

24881

371.36

... More
Wiring 3 pin 16/20 amp. power plug control point

624

298290

478.03

... More
Wiring light point without control switch.

92

30773

334.49

... More
Wiring light point with double control switches.

32

42434

1326.09

... More
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).

2

1415

707.95

... More
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-

-

-

-

... More
Ceiling Rose (Flush Piano type)

36

1308

36.35

... More
Call Bell 220/230 volts AC Ding Dong

1

132

132.06

... More
LED'S FIXTURES & FANS:

-

-

-

... More
Supply and erection of Slim Recessed mounted, Round downlighter 12 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.

49

70658

1442

... More
Supply and erection of Slim Recessed mounted, Round downlighter 15 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.

8

12792

1599

... More
Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.

171

293607

1717

... More
Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD 10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.

3

2343

781

... More
Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD 10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.

498

545310

1095

... More
Supply and erection of Linear Suspended mounted 28/30watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD 10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.

9

53685

5965

... More
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.

84

299376

3564

... More
Supply and erection of Wall Fan Plastic Body 400MM, 16" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.

9

31149

3461

... More
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.

36

163260

4535

... More
OCCUPANCY SENSORS:

-

-

-

... More
Supply and erection of Ceiling mounted Occupancy based PIR sensor (360 degree)with installation height 2.5mts ,8.5 Amps resistive load, Detection dia 8M,time delay - 5s to 59 mins , Light level threshold - 5 to 1275 Lux ,IP - 20,Sensitivity Adjustment, Walk LED test, with additional options like walkthrough, daylight set point, vacancy .

36

269100

7475

... More
SUSPENSION RODS FOR CEILING FANS:

-

-

-

... More
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-

-

-

-

... More
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan.

34

4477

131.69

... More
CONDUIT PIPE & COPPER WIRES:

-

-

-

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-

-

-

-

... More
Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed

1340

81029

60.47

... More
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed

450

31860

70.8

... More
Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed

100

9734

97.34

... More
Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed

1424

182727

128.32

... More
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 1sq.mm (Un-sheathed)

5470

104859

19.17

... More
Overall size 1.5sq.mm (Un-sheathed)

50

1232

24.65

... More
Overall size 2.5sq.mm (Un-sheathed)

2190

80986

36.98

... More
Overall size 4sq.mm (Un-sheathed)

4380

233935

53.41

... More
Overall size 6sq.mm (Un-sheathed)

1670

123513

73.96

... More
Overall size 10sq.mm (Un-sheathed)

4808

579460

120.52

... More
Overall size 16sq.mm (Un-sheathed)

2936

550881

187.63

... More
Overall size 25sq.mm (Un-sheathed)

400

118328

295.82

... More
SUB DISTRIBUTION SYSTEM:

-

-

-

... More
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-

-

-

-

... More
TP&N Vertical Double Door Distribution Board 4 way each.

10

67663

6766.37

... More
TP&N Vertical Double Door Distribution Board 8 way each.

18

153328

8518.23

... More
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-

-

-

-

... More
Cable End Box for TPN Vertical 4/8/12Way

28

50465

1802.33

... More
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-

-

-

-

... More
MCB Single Pole 6-32amp. (10kA, Curve-C)

504

96052

190.58

... More
MCB Four Pole 40amp. (10kA, Curve-C)

15

22976

1531.74

... More
MCB Four Pole 50, 63amp. (10kA, Curve-C)

13

22759

1750.76

... More
MAIN DISTRIBUTION SYSTEM:

-

-

-

... More
MAIN VERTICAL DISTRIBUTION BOARD (EMERGENCY): TPN 4Way to feed MCB DB's (EMERGENCY LOAD) ON GROUND FLOOR

-

-

-

... More
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-

-

-

-

... More
TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp)

1

7638

7638.67

... More
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-

-

-

-

... More
MCCB Four Pole 100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

1

6626

6626.73

... More
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-

-

-

-

... More
MCB Triple Pole 40amp. (10kA, Curve-C)

4

4755

1188.98

... More
RISING MAIN: (IN ELECTRICAL ROOM)

-

-

-

... More
UPS RISING MAIN:

-

-

-

... More
Supply, Installing testing and commissioning of 200A, 25KA Air Insulated Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every meter, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required complete in all respects as approved and desired by the Engineer-in-charge at site.

28

182812

6529

... More
Supply, installation, testing & commisioning of 200 Amp Main End Feed Unit Box (with provision of MCCB but without MCCB )on the existing Air Insulated rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C supply with Flange End, Rotary Handel, box made with 1.6mm thick G.I sheet steel enclosure (IP54) duly powder coated complete in all respects as approved and desired by the Engineer-in-charge at site.

2

20984

10492

... More
EMERGENCY & NORMAL RISING MAIN:

-

-

-

... More
Supply, Installing testing and commissioning of 300A, 25KA Air Insulated Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every meter, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required complete in all respects as approved and desired by the Engineer-in-charge at site.

14

105518

7537

... More
Supply, installation, testing & commisioning of 300 Amp Main End Feed Unit Box (with provision of MCCB but without MCCB )on the existing Air Insulated rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C supply with Flange End, Rotary Handel, box made with 1.6mm thick G.I sheet steel enclosure (IP54) duly powder coated complete in all respects as approved and desired by the Engineer-in-charge at site.

1

13197

13197

... More
Supply, installation, of Tap off box for with provision of MCCB Four Pole 40-63Amp. (Excluding MCCB Cost) complete in all respects as approved and desired by the Engineer-in-charge at site.

27

157950

5850

... More
Supply, installation, of Tap off box for with provision of MCCB Four Pole 80-100Amp. (Excluding MCCB Cost) complete in all respects as approved and desired by the Engineer-in-charge at site.

1

6349

6349

... More
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-

-

-

-

... More
MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

8

53013

6626.73

... More
MCCB Four Pole 63amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

19

125907

6626.73

... More
MCCB Four Pole 80-100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

1

6626

6626.73

... More
MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

2

25728

12864.08

... More
MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting

1

34133

34133.61

... More
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-

-

-

-

... More
PVC flexible pipe 40mm dia.

56

1947

34.77

... More
Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:-

-

-

-

... More
PVC compression Socket gland 40mm dia.

56

1828

32.66

... More
INDOOR LT PANELS:

-

-

-

... More
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work .

-

-

-

... More
Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:-

-

-

-

... More
SUB LT PANEL (NORMAL):

-

-

-

... More
LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 4Nos. outgoing MCCB's 100amp. to 160amp. according to the requirement at site (Approx. size 2025 x 1100 x 400mm) (DETAIL SEE IN PANEL INVENTORY)

1

93258

93258.35

... More
SUB LT PANEL (EMERGENCY):

-

-

-

... More
LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 8Nos. outgoing MCCB's 40amp. to 160amp. according to the requirement at site (Approx. size 1750 x 1750 x 400mm) (DETAIL SEE IN PANEL INVENTORY)

1

128637

128637.3

... More
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc

-

-

-

... More
MCCB Four Pole 40/63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

8

61957

7744.7

... More
MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

3

41946

13982.05

... More
MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting

3

105754

35251.58

... More
EARTHING SYSTEM (INDOOR):

-

-

-

... More
COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-

-

-

-

... More
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long

2

22288

11144.34

... More
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-

-

-

-

... More
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)

40

13746

343.65

... More
COPPER EARTHING :- (Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-

-

-

-

... More
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)

2

37326

18663.38

... More
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)

4

81284

20321.17

... More
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-

-

-

-

... More
Additional Length 20mm x 3mm thick Copper Tape .

50

25884

517.69

... More
Additional Length 25mm x 3mm thick Copper Tap

100

63716

637.16

... More
INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES:

-

-

-

... More
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-

-

-

-

... More
Overall size 6sq.mm (2Core) Un-armoured (Loose)

100

6584

65.84

... More
Overall size 16sq.mm (4 Core) Un-armoured (Loose)

200

26338

131.69

... More
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)

100

36873

368.73

... More
Overall size 95sq.mm (3½ Core) Un-armoured (Loose)

100

45301

453.01

... More
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-

-

-

-

... More
Cable Tray Size 300mm x 50mm x 50mm (2mm thick)

10

14557

1455.73

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-

-

-

-

... More
Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)

280

34218

122.21

... More
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)

140

23156

165.4

... More
Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.)

5

1285

257.05

... More
Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)

5

1538

307.62

... More
Double Walled Corrugated HDPE Pipe 180/152mm (Outer/ Inner dia.)

5

1964

392.96

... More
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-

-

-

-

... More
Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm

10

771

77.12

... More
Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm

10

1302

130.21

... More
Brass Gland for Aluminium cable 2/3/3½/4 Core size 70sq.mm

10

1908

190.89

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 95-120sq.mm

10

2515

251.58

... More
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-

-

-

-

... More
Aluminium thimble cable Core size 4 - 6sq.mm

20

274

13.7

... More
Aluminium thimble cable Core size 10 -16sq.mm

20

295

14.75

... More
Aluminium thimble cable Core size 25 -35sq.mm

20

358

17.91

... More
Aluminium thimble cable Core size 50sq.mm

10

284

28.44

... More
Aluminium thimble cable Core size 70sq.mm

20

632

31.61

... More
Aluminium thimble cable Core size 95sq.mm

20

737

36.87

... More
Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-

-

-

-

... More
Copper thimble cable Core size 4 - 6sq.mm

200

4362

21.81

... More
Copper thimble cable Core size 10 - 16sq.mm

200

5330

26.65

... More
SAFETY EQUIPMENTS:

-

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

12

1200

100

... More
Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

12

924

77

... More
Providing and fixing of Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity.

12

84864

7072

... More
Supply and fixing of foam fire extinguishers, Portable type 9 Litre capacity hanged on wall with bracket component as required.

12

47904

3992

... More
Total D1:

-

-

-

... More
Providing Advance Lightning Protection System:

-

-

-

... More
Supply, erection, testing & commisioning of Early Streamer Emission (ESE) type Lightning Protection Complete with Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome body capable of working in hazardous atmosphere and protecting against direct Lightning point as well conducting /diverting it to earth completely after tracing the Lightning in advance. As per NF C 17-102:2011 the air terminal should be tested for Lightning impulse current (10/350 micro sec) =100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shall offer a protection radius of 79mtr., Level-1 High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast. (Its working principle evolves from local electrostatic field that develops naturally around the system as a thunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering device generates high tension pulses at the conductor tip, causing a ‘corona effect’.) Protection radius of 79Mtr at level 1 & 107 Mtr at level 4

1

98259

98259

... More
Supply and fixing of GI Mast 5 mtr. height along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector /Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conducto, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required.

1

13579

13579

... More
Supply and installation of Lightning Strike Counter (6 digit display) of non-resettable (electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system. This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures. It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs. above the ground level.

1

13243

13243

... More
Supply & erection of test Link of non-corroding, weather proof, water proof polycarbonate IP 65/55 enclosure including providing of 2 Nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire. The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor.

1

3206

3206

... More
Supply, installation & testing of chemical earthing (Maintenance Free Earthing) system with UL approved copper bonded rod and exothermically welded copper busbar both tested by CPRI at 50kA Fault Current. A copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper coating thickness of minimum 250 microns. Along with earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A copper clad steel solid ground wire of 8 mm dia. for interconnecting earth pits. Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber. The grounding minerals should not be pollute the ground water. The grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr.

3

37794

12598

... More
Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20,Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge.

4

11609

2902.48

... More
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 70sq.mm (Un-sheathed) (Conductor connected the air terminal to earthing)

150

120178

801.19

... More
Total D2:

-

-

-

... More
Providing 2Nos. 26 Passenger Lifts, 4Stops:

-

-

-

... More
Supply, installation, testing and commissioning of 1 No. lift of 26 passengers machine room less. Type and Capacity : Approximately 1768 Kg, 26/27 Passengers Speed:1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately 10.8 meter________ Serving: _4 Floors _4 Stops _4 Openings _4 Levels (All on the same side) Hoist way Required: 2400mm (Wide) x 3000mm (Deep) Clear dimensions Headroom Height (HR): 5000 mm beyond finished floor level of last landing Pit Depth: 1800mm below the finish floor level of first landing Car Size Area: Minimum 3.74 square meter and Maximum 3.85 square meter Car Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof). Car Entrance: Center Opening Automatic Doors with vision panel (40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 900mm (wide) x 2100mm (high) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features.

-

-

-

... More
Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight. 29. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.

2

6599340

3299670

... More
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-

-

-

-

... More
Overall size 16sq.mm (4Core) Un-armoured (Loose)

160

21070

131.69

... More
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-

-

-

-

... More
Overall size 16sq.mm (4Core) Un-armoured (On-Surface)

80

12115

151.44

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-

-

-

-

... More
Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)

150

23388

155.92

... More
COPPER EARTHING (8 SWG COPPER EARTHING): Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-

-

-

-

... More
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long

4

44577

11144.34

... More
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)

80

26076

325.95

... More
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.

-

-

-

... More
MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

2

13253

6626.73

... More
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-

-

-

-

... More
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)

2

6684

3342.12

... More
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-

-

-

-

... More
SP&N Double Door Distribution Board 8 way each

2

2832

1416.27

... More
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-

-

-

-

... More
Cable End Box for SPN 8 Way

2

1358

679.3

... More
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-

-

-

-

... More
MCB Single Pole 6-32amp. (10kA, Curve-C)

12

2286

190.58

... More
MCB Double Pole 6-32amp. (10kA, Curve-C)

2

1160

580.27

... More
Total D3:

-

-

-

... More
Providing EPABX System:

-

-

-

... More
Supply, installtion, testing & commisioning of the Switching system of the EPABX should be designed with IP at the core allowing fully distributed IP solutions across data networks in 19” Rack Mountable,7 universal slots in single Node and should support card Analog Extension Card , Digital Extension Card , for the respective addition / expansion. Analog & Digital extensions can be increased in the steps of 8, 16 & 32 Ports.Analog Trunks , PRI, BRI Trunks, E1 & SIP Trunks . Single card/module should support 2 or more PRIs, It should support 100% IP or 100 % TDM or a hybrid of IP/TDM technologies. The system should support IP Communication Devices (wired and wireless) e.g. IP Phones (Hard and Soft phones), Mobile IP Phones, multimedia PCs, SIP phones, Video phones (Hard & soft), etc.1.3. The system should also support Legacy TDM communication devices (Digital and analog 2 Wire telephone instruments with or without caller-id (Both FSK and DTMF), Fax, modems, ISDN phones etc. 1.6. The proposed system should support direct SIP integration with Microsoft Lync 2013 including following. Vendor should provide proper document towards certification with Microsoft Lync 2013 integration.1.16. The system should support at least 228 analog extensions in a single node and up to 600 analog Extensions in multiples nodes,at least 400 Digital Phones in a single node and 600 digital phones in multiple node,support at least 600 SIP extensions in a single node,Support 600 DECT/SIP DECT phones.support at least 224 DECT base stations and over 4000 SIP-DECT Base stations.should support minimum 56 Analog Trunks ,56 ISDN BRI trunks,14 PRI Trunks.Fax over IP with T.38 Interface and should support minimum 140 channels.240 SIP access channels.1.26. The system should have in-built Auto Attendant and 2 Port Voice Mail, Direct Inward System Access (DISA), Direct Outward System Access (DOSA) & Music On Hold (MOH). The system should be communication server should be on Leaders of Gartner Magic Quadrant. The OEM should be present globally minimum 70-75 countries. EPABX/Server, Digital Phone, IP Phone, cloud server must be from same OEM. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 15 years experience with same OEM & have already maintained services minimum 18-20 EPABX system in Punjab region. complete in all respect as per satisfaction of the Engineer in charge of the work.

1

182565

182565

... More
Supply, installtion, testing & commisioning of card 08 PNT Line (backup Lines) complete in all respect as per satisfaction of the Engineer in charge of the work.

1

46872

46872

... More
Supply, installtion, testing & commisioning of card 32 Analog Extensions complete in all respect as per satisfaction of the Engineer in charge of the work.

1

79710

79710

... More
Supply Installation Testing and Commissioning of the Sip Extension with its license for IP telephones complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

6

27006

4501

... More
Supply Installation Testing and Commissioning of SIP Phone Up to 2 lines on dedicated line keys with LEDs 3 programmable keys that come pre-programmed and labeled with default values (Callers, Redial and Transfer) 4-way navigation with Select/OK key Dedicated function keys, including Transfer, Callers List, Hold, Redial, Goodbye, Options, 2 volume keys, Mute (with LED) and Speaker (with LED) Audio and Codecs,Hi-Q Audio . (HAC) handset,Full-duplex quality speakerphone,Wideband handset and speakerphone, Codecs: G.711 μ-law / A-law, G.729, G.722, AMR*, AMR-WB(G.722.2)*, G.726, iLBC, BV16, BV32, L16,Echo cancellation,Comfort noise utilization, Packet loss, concealment, Monochrome LCD ,2.75” 128x48 pixel graphical displa LED for call and message waiting indication,Security User and administrator level passwords for login Encryption of configuration files, HTTPS configuration downloaded and web managementPhone lock with PIN,Digest Authentication,Transport Layer Security (TLS), Secure Real-Time Protocol (SRTP),XML API Capabilities,RTP Streaming Control, CTI applications Dual 10/100 Mbps Ethernet ports with hardware based Ethernet switch Manual or Dynamic Host Configuration Protocol (DHCP) IP address setup Support of multiple DHCP options: 2, 12, 42, 43, 60, 66, 77, 120, 132, 159, 160 Time and date synchronization using SNTP, Quality of Service support – IEEE 802.1 p/Q VLAN and priority tagging, Type of Service (TOS), and Differentiated Services Codae Point Integrated HTTP/HTTPS server for web administration and maintenance including a built-in troubleshooting sectionMass deployment via central provisioning of user configuration files – TFTP, FTP, HTTP, HTTPSTR-069 support,PoE Class 1 Level “V” energy efficiency rated power adapters available complete in all respects as approved and desired by the Engineer-in-charge at site.

6

60060

10010

... More
Supply Installation Testing and Commissioning & Laying of Cat 6 Cable in existing conduit Category 6 Unshielded Twisted Pair 23 AWG:305mtr. ,4 pair 100W cable shall be compliant with ANSI/TIA/EIA-568-C.2 Additional Transmission Performance Specifications for 4-pair 100W Category 6Cabling. Tested upto 600 MHZ; Construction: 4 twisted pairs separated by internal X shaped, 4 channel, polymer spine / full separator. Half shall not be accepted.Sheath : FRPVC/LSZH,Outer Diameter 6.1 mm nominal;Temperature Range -20° to +60°C.Manufacturer should have ISO 9001:2008 Certification for Quality Management System.Manufacturer should have ISO 14001:2004 Certification for Environmental Management System.All UTP and Its Components should be from same OEM. complete in all respects as approved and desired by the Engineer-in-charge at site.

200

11400

57

... More
Supply Installation Testing and Commissioning of L2+ Managed Industrial Grade POE Switch 10 Ports Gigabit Managed Industrial Grade POE Switch , 8 10/100/1000 Base- TX portand 2 Gigabit SFP slotand 1console port Network Protocols: Support , IEEE802.3, IEEE802.3u, IEEE802.3z , IEEE802.3ab , IEEE802.3x , IEEE802.1d , IEEE802.1w , support IP camera All Make : Netgear, Cisco. Mountxross,allied telesis, should Working temperature:-40~75℃ Storage temperature:-40~85℃, Relative Humidity : 5%~95% (no condensation), Shell : IP30 protectgrade, metal shell Installation : DIN- Railor Wallmounts, MTBF : 300,000 hours , Make : Netgear, Cisco. Mountxross,allied telesis Support L2+ Switching features including 802.1Q VLAN, Mirroring, Portisolation, IGMP Snooping, DHCP Snooping, LLDP, IP Source Guard, ARP inspection, ACL setc. Support spanning tree STP(802.1D) and RSTP(802.1W).802.1s(MSTP) way exchange time 50ms Jumbo frames support upto 9.6 Kkilobytes Support enhanced managemen through WEB,CLI, TELNET, SSH, SNMP Ethernet port support 10/100/1000 Mself-adaption.Bandwidth: 24Gbps, Packet Buffer Memory: 4M Packet Forwarding Rate:1488000 pps /port Address Table : 8K complete in all respects as approved and desired by the Engineer-in-charge at site.

1

51586

51586

... More
Supply Installation Testing and Commissioning of Analog phone with caller id and hand free facility complete in all respects as approved and desired by the Engineer-in-charge at site.

30

47010

1567

... More
Supply Installation Testing and Commissioning of 20 Pair DB with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

56584

14146

... More
Supply Installation Testing and Commissioning of 50 Pair MDF with Krone for EPBAX side with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

1

25369

25369

... More
Supply, Installation Testing and commissioning of unarmoured 2 Pair 0.5 sq. mm copper conductor PVC insulated Cable for Telephones in existing Conduit complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

550

20350

37

... More
Supply, Installation, Testing & Commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90% complete in all respects as approved and desired by the Engineer in-charge at site.

1

15539

15539

... More
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring Telephone socket point RJ11 (one module)

30

10657

355.24

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-

-

-

-

... More
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed

500

35400

70.8

... More
Total D4:

-

-

-

... More
Providing Networking & Display System along with allied accessories:

-

-

-

... More
Supply, Installation and Comissioning of Distribution Switch with minimum usable 24 10/100/1000BASE-T ports, 2 10GBASE-T ports , 4 10G SFP+ ports L3 Stackable Managed Switch with Redundant Power Supply Support.1 x RJ45 console port, RJ-45 port for out-of band-management port for accessing the CLI of the switch and USB port. 168 Gbps Switching capacity or higher or non-blocking architecture. 64 Bytes packet forwarding rate should be 125 Mpps or higher. Switch MAC table should be at least 16K or higher. Physical Stacking up to 9 units per stack. Stacking bandwidth up to 80G and up to 32 devices per virtual stack. Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol and ERPS as per standard ITU-T G.8032. BPDU Filter, BPDU restriction, Root restrction. Loopback detection (LBD). IGMP Snooping v1/V2/V3 & IGMP groups 1K or more IGMP groups and require support for IGMP Snooping Fast Leave. MLD Snooping v1/v2 & MLD group 1K or more and require support for MLD Snooping Querier. 16 L3 IP interfaces and IPv4/IPv6 Loopback interface. IPv6 Neighbor Discovery (ND). VRRPv3, Equal-Cost Multi-Path (ECMP) and UDP helper. Static route for both IPv4 and IPv6, OSPFv1, v2 & v3, RIP V1/V2/ng. Should have Policy-based Route (PBR). IEEE 802.1Q VLAN with different type of VLAN like Port based, Voice VLAN, Private, Double (Q-In-Q), Multicast VLAN (ISM VLAN for IPv4/IPv6), 802.1v Protocol VLAN ,VLAN Trunking. should have per-port broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. port security to secures the access port based on MAC address. Require prevention of DoS attacks, which include Land, Blat, TCP Null Scan, TCP Xmas Scan, TCP SYNFIN, Ping of Death Attack and TCP Tiny Fragment attack. DHCP snooping and DHCP server screening, DHCP server. 802.1X port based and 802.1X host based access control, Identity-driven Policy (VLAN, ACL or QoS) Assignment. RADIUS and TACACS+ authentication. Authentication database failover. QoS (quality of service) IEEE 802.1P for traffic prioritization. 8 queues per port. Different type of QoS priority like Strict Priority Queue and Weighted Round Robin, Strict + WRR, Congestion control using Weighted Random Early Detection (WRED) or WTD. Remark 802.1p priority, Remark ToS/DSCP and Rate limiting in Policy map. Support at least 2K ingress & 512 egress access control entries. ACL based on MAC, IPv4 and IPv6, TCP/UDP port number, User-defined packet contentm, CPU Interface Filtering. Able to manage trough Web-GUI, Fully functional CLI interface and Telnet. Should have multiple Image and configuration support to reduced down time for the switches. sFlow for monitoring traffic in data networks, SNMP v1, v2c, v3 and SNMP Traps and RMON. Support for DHCP Client support for IPv4/IPv6, DHCP server, DHCP Relay and DNS client. Should have SNTP/NTP protocol for time synchronization. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED.. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED. Operating temperature should be 0 to 50 ˚C. Switch should be EMI Certificates FCC, CE and Safety Certifications cUL/UL, CB. All Switches, Wireless and its Networkiing Components from Same OEM. OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. OEM should have Indian based operation at least for a period of 20+ years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years.  (To ensure only principal networking companies participate having strong Product , Support and Service.) complete in all respect as per satisfaction of the Engineer in charge of the work.

2

307188

153594

... More
Supply, Installation and Comissioning of CAT 6 Cable should be Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 Cabling system.Conductors should be 23 AWG solid bare copper.Netowork support should be ultrahigh speed data networks such as Gigabit Ethernet (1000 Base-T and 1000 Base-TX) and beyond.Cable Should be ETL/UL Certificates are mandatory.Frequency tested up to should be 600 MHz minimum.Impedance should be 100 Ohms + / - 15 ohms.Box Packing shoud be 305M.Should be 25-year systems warranty; Warranty to cover Bandwidth of the specified and installed cabling system, and the installation costs. Site certificate Should be issued by OEM.Should be RoHS compliant. complete in all respect as per satisfaction of the Engineer in charge of the work.

550

31350

57

... More
Supply, Installation and Comissioning of Patch Panel should be made of cold rolled steel.Should conform to TIA / EIA 568-C.2 Component Compliant.Should terminate 24 UTP CAT 6 (4 pair) Cables.Should confirm to EIA/TIA 568A wiring Pattern.Each port Should be features the spring-loaded shutter.Should be prevents incomplete mating Should be protects from dust and contaminants.Should be Front and rear port labelling as well as panel identification label.Should be Integral cable management shelf ensures bend radius compliance.Operating Life should be minimum 750 insertion cycles.Should be RoHS compliant.complete in all respect as per satisfaction of the Engineer in charge of the work.

2

18696

9348

... More
Supply, Installation and Comissioning of Patch Cord 1 Mtr Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant. complete in all respect as per satisfaction of the Engineer in charge of the work.

48

10032

209

... More
Supply, Installation and Comissioning of atch Cord 2 Mtr. Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant complete in all respect as per satisfaction of the Engineer in charge of the work.

29

6902

238

... More
Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work.

2

26756

13378

... More
Supply, Installation, Testing & Commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90% complete in all respects as approved and desired by the Engineer in-charge at site.

2

31078

15539

... More
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-

-

-

-

... More
Wiring Networking socket point RJ45 (one module)

29

13381

461.43

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-

-

-

-

... More
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed

500

35400

70.8

... More
Total D5:

-

-

-

... More
Providing CCTV System:

-

-

-

... More
Supply, erection, testing & commissioning of IP indoor Camera Image Sensor 1/2.8" SONY Starvis Back-illuminated CMOS Sensor Resolution 2MP 1080 P Effective Pixels 1945(H)*1097 (V) Compression H.264/H.264+/H.265/H.265+/ JPEG/AVI /MJPEGTV System PAL/NTSC Electronic Shutter Time Auto: PAL 1/25-1/10000 Sec; NTSC 1/30-1/10000 Sec Minimun Illumination 0.005Lux S/N Ratio≥52dB Scanning System Progressive Video Output Network Reset Button Optional Focus Length 2.7-13.5mm Motor Zoom Focus Control Auto Lens Type Auto Pixels 2MP Infrared LED No, Support Warm light LED 4000 K, up to 30m Infrared Distance IR Status Auto Control IR Power On Smart, Manual & Timed mode Ethernet RJ-45 (10/100Base-T) Protocol TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP,  RTCP ,PP PoE, NTP,  SMTP, UDP, SNMP ON VIF Support ON VIF 19.12(Profile S/T/G)P2P YES, Support QR Code POE Optional, Support IEEE 802.3 af Video Delay 0.3S (Within the Lan) Main Stream 12304*1296@25fps, Main Stream 21920*1080@30fps, Main Stream 31280*720@30fps, Sub Stream 11280*720@30fps 720*480@30fps Sub Stream 2352*288@30fps Tri Stream1280*720@30fps 720*480@30fps 352*288@30fps IE Brower IE8-11, Google Chrome, Firefox , Mac Safari Smart Phone iPhone, iPad, Android, Android Pad Intelligent Analysis Face Detection, Intrusion Detetion, Line Cross Detetion, Loiter Detetion, People Gather Detecion, motion detection based on human detection Day/Night Color/ B&W (IR-CUT )Image Config Saturation /Brightness/Contrast /Sharpness, Mirror, 3D NR , White Balance, FLK (Flicker Control), Video Tampering, HLC, Distortion Full Stat light Corridor Pattern Defog  Mode ROIBLC WDR HDR: 120dB Motion Detection Support  Privacy  Masking 3 Rectangular Zone Recording Mode NVR/CMS/ Web Audio Optional 1 Built-in MIC  Alarm Optional 1 Channel Input / Ouput SD Card Slot Optional Internal, Support Max 512GB RS485 Housing Metal ,IP67 , Contactor shall off load the work to OEM & have its own registered office in Punjab for sale & support of product. Camera & NVR should be from same OEM. IR Cut Filter Operation Temperature-20℃ ~ +60℃ RH95% Max Storage Temperature-20℃ ~ +60℃ RH95% Max Power Source DC12V±10%, 1000mA Dimension¢128 x 108(H)mm. Camera Should be BIS certified. Awared company must have minimum 5 years work experiance in networking & CCTV. Also have completed the similar amount of awarded job.complete in all respect as per satisfaction of the Engineer in charge of the work.

18

475704

26428

... More
Supply, erection, testing & commissioning of 5MP Outdoor Face Detection IP Network Camera Image Sensor 1/2.8" SONY Starvis Back-illuminated CMOS sensor Resolution 5MP Effective Pixels 2616 (H)*1964 (V) Compression H.264/ H.264+/ H.265/ H.265+/ JPEG/ AVI /MJPEG TV System PAL/NTSC Electronic Shutter Time Auto: PAL 1/25-1/10000 Sec; NTSC 1/30-1/10000 Sec Minimun Illumination 0.01Lux S/N Ratio ≥52dB Scanning System Progressive Video Output Network Reset Button Optional Lens Focus Length 2.7-13.5mm Motor Zoom Focus Control Auto Lens Type Auto Pixels 4MP Night Vision Infrared LED No, Support Warm light LED 4000K, up to 40m IR Status Auto Control IR Power OnSmart, Manual & Timed mode Network Ethernet RJ-45 (10/100Base-T)Protocol TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP,  RTCP ,PPPoE, NTP,  SMTP, UDP, SNMP ONVIF Support ONVIF 19.12 (Profile S/T/G)P2P YES, Support QR Code POE support, Support IEEE 802.3af Video Delay 0.3S (Within the Lan) Main Stream 12592*1944@30fp Main Stream 22560*1440@30fp Main Stream 31920*1080 @30fps 1280*720@30fps Sub Stream 11280*720@30fps720*480@30fps Sub Stream 2352*288@30fps Tri Stream 1280*720@30fps 720*480@30fps 352*288@ 30fps IE Brower IE8-11, Google Chrome, Firefox , Mac Safari Smart Phone iPhone, iPad, Android, Android Pad AI Function Intelligent Analysis Face Detection, Intrusion Detetion, Line Cross Detetion, Loiter Detetion, People Gather Detecion, motion detection based on human detection Day/Night Color/ B&W (IR-CUT ) Image Config Saturation/Brightness/Contrast /Sharpness, Mirror, 3D NR , White Balance, FLK(Flicker Control), IP camera should be compatible with Axis, Pelco, Bosch, Mountxross, Mobitech network video recorder Video Tampering, HLC, Distortion Full Color Corridor Pattern Defog  Mode ROIBLC WDR HDR: 120dB Motion Detection Privacy  Masking 3 Rectangular Zone Recording Mode NVR/CMS/Web Interface Audio Optional 1 Built-in MIC Alarm Optional 1 Channel Input/Ouput SD card Support Max 512GB Housing Metal, IP67 Contactor shall off load the work to OEM & have its own registered office in Punjab for sale & support of product. Camera & NVR should be from same OEM. IR Cut Filter Operation Temperature-20℃ ~ +60℃ RH95% Max Storage Temperature-20℃ ~ +60℃ RH95% Max Power Source DC12V±10%, 1000 m A Dimension 268(W) x 95(H) x 88(D)mm. Camera Should be BIS certified. Awared company must have minimum 5 years work experiance in networking & CCTV. Also have completed the similar amount of awarded job. complete in all respect as per satisfaction of the Engineer in charge of the work.

3

85641

28547

... More
Supply, erection, testing & commissioning of PoE Spliliter 12 volt, 1 Amp, IP66 For High Voltage Protection complete in all respect as per satisfaction of the Engineer in charge of the work.

21

32802

1562

... More
Supply, erection, testing & commissioning of 64 CH NVR with Main Processor ARM Cortex A17 Quad-core Processor Operating System Embedded LINUX, Video Input 64CH (4000×3000, 3840×2160, 2592x1944, 2048x1536, 1920×1080, 1280×960, 1280×720, etc)Output  1 VGA, 2 HD, Audio Input 1 Port RCA Output 1 Port RCA (Linear, 1kΩ), Audio Bit Rate 64 kbps, Audio Compression standard AAC, G711u, G711a, ADPCM_DVI4 Intercom support (two-way) Motion Detection 64 Channel, MD Zones: 396 (22 × 18), Trigger Events Recording, Email, FTP, Snapshot, Buzzer and Screen Tips, alarm output Display HD Output 14K (3840 × 2160)/30Hz, 1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz HD, Output 21920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, VGA     1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, Display Split 64CHxD1/ 36CHxD1/ 25CHxD1/ 16CHxD1/ 9CHxD1/ 4CHxD1/ 1CHx1080P/ 1CHx3MP/ 1CHx4MP/ 1CHx5MP/ 1CHx4k/ 1CHx12MP Digital Zoom  YES, OSD Camera Title, Time, Recording, Motion Detection, Event Alarm Recording Video Compression H265/ H264/ H265+ /H264+ Resolution 12MP (4000×3000), 4k(3840×2160), 5MP(2592×1944), 4MP(2688×1520/2560×1440), 3MP(2048×1536), 1080P(1920×1080), 960P (1280x960), 720P(1280×720), D1 (720×576/ 720×480) Record Rate  PAL:12MP@29×25fp, 4k@35×25fp, 5MP@58×25fp, 4MP@64x25fp, 3MP@64×25fp, 1080P@64×25fp, 960P@64×25fp, 720P@64×25fp, D1@64×25fp NTSC:12MP@29×30fp, 4k@35×30fp, 5MP@58×30fp, 4MP@64×30fp, 3MP@64×30fp, 1080P@64×30fp, 960P@64×30fp, 720P@64×30fp, D1@64×30fp, Record Mode Manual\ Timer\ Motion Detection\ Alarm Input\ Smart Event Local Sync Playback 3CH 12MP@15fps, 4CH 4K@30fps, 6CH 5MP@30fps, 8CH 4MP@30fps, 10CH 3M@30fps, 16CH 1080P@30fps, 16CH 960P@30fps, 16CH 720P@30fps, 16CH D1@30fps, Decode Capability 4CH 4K(3840×2160)@30fps, Remote Sync Playback YES Search Mode ALL, Channel, Manual, Time, Date, Motion Detection, Event Alarm, Tag search Playback Functions Play, Pause, Stop, Rewind, Fast play, Slow Play, Full Screen, Frame Play ,Frame Rewind, Digital Zoom,tag, clip Backup Mode USB Device/ Network Network Interface 2 RJ-45 10/100/1000 Mbps self-adaptive Ethernet interfaces Incoming Bandwidth 300MB Network Functions TCP/IP, HTTP, UPnP, DNS, NTP, SMTP, DHCP, FTP, DDNS, RTSP, RTCP, p2p, PP POE Onvif onvif S, onvif T Web Browser Edge, IE8-11, Google Chrome , Firefox , Safari CMS Software Support  Windows 7/ Windows 8/ Windows 10/ MAC OS Cloud Support Yes Smart Phone iPhone, iPad, Android, Android Pad Interface Type  8 SATA Hard Disk Interface (3.5" SATA) Capacity Up to 64TB, capacity eSATA 1 eSATA.ontactor shall off load the work to OEM & have its own registered office in Punjab for sale & support of product. Camera & NVR should be from same OEM. interface Language  UI English, Polish, Czech, Russian, Thai, Hebrew, Arabic, Bulgarian, German, French, Portuguese, Turkic, Spanish, Italian, Hungarian, Romanian, Korean, Dutch, Greek,  Vietnamese USB Interface 2 USB 2.0 Interfaces ,1 USB 3.0 Interface RS485 2 Port Power Supply AC 115 to230V, 3A Working Environment-10~55℃/10~90% Dimension (W×D×H)2U, 440mm × 450mm×95mm Weight 9.8Kg (without HDD. NVR Should be BIS certified. Awared company must have minimum 5 years work experiance in networking & CCTV. Also have completed the similar amount of awarded job. complete in all respects as approved and desired by the Engineer-in-charge at site.

1

179986

179986

... More
Supply, erection, testing & commissioning of L2+ Managed Industrial Grade POE Switch 10 Ports Gigabit Managed Industrial Grade POE Switch , 8 10/100/1000 Base- TX portand 2 Gigabit SFP slotand 1console port Network Protocols: Support , IEEE802.3, IEEE802.3u, IEEE802.3z , IEEE802.3ab , IEEE802.3x , IEEE802.1d , IEEE802.1w , support IP camera All Make. Netgear, Cisco. Mountxross, D link, should Working temperature:-40~75℃ Storage temperature:-40~85℃, Relative Humidity : 5%~95% (no condensation), Shell : IP30 protectgrade, metal shell Installation : DIN- Railor Wallmounts, MTBF : 300,000 hours , Support L2+ Switching features including 802.1Q VLAN, Mirroring, Portisolation, IGMP Snooping, DHCP Snooping, LLDP, IP Source Guard, ARP inspection, ACL setc. Support spanning tree STP(802.1D) and RSTP(802.1W).802.1s(MSTP) way exchange time 50ms Jumbo frames support upto 9.6 Kkilobytes Support enhanced managemen through WEB,CLI, TELNET, SSH, SNMP Ethernet port support 10/100/1000 Mself-adaption.Bandwidth: 24Gbps, Packet Buffer Memory: 4M Packet Forwarding Rate:1488000 pps /port Address Table : 8K complete in all respects as approved and desired by the Engineer-in-charge at site.

3

154758

51586

... More
Supply, erection, testing & commissioning of Access Switch 24 10/100/1000BASE-T PoE and 4 100/1000 Mbps GbE/SFP combo ports, IEEE 802.3az Energy Efficient Ethernet (EEE),IEEE 802.3x Flow Control, IEEE 802.3af/at compliance (for PoE ports),9K Jumbo frame,256 Multicast Groups,802.1W RSTP, 802.1s MSTP, IGMP Snooping, Loopback Detection, 802.3ad Link Aggregation, Auto Surveillance VLAN, 802.1p Quality of Service with 8 queues per port,Supports 4 IP interfaces,Min 124 static route entries, Min 768 ACL Rules, SSH, TLS,DoS attack prevention, 802.1X Port-based Access Control, Port Security, Cable diagnostics, Dual image, Dual configuration, NMS Bundled along with Switch,OEM Should be present in Gartner Magic Quadrant from past 5 Years complete in all respects as approved and desired by the Engineer-in-charge at site.

1

57465

57465

... More
Supply, erection, testing & commissioning of 27U Network Enclosure Frame-600X800-STEEL with accessories like fan, pdu, cable manager etc. SITC of 27U Enclosure Frame-800X1000-STEEL, Caster Wheels Set of 4 (2 with Brakes & 2 without Brakes),Adjustable Levellers set of 4, Glass Door-800-27U, Metal Door-800-27U-Vented, Side Panels-1000-27U-Vented, Mounting Hardware-(Pack of 20), FHU with 4 FAN 360CFM, Vertical Power Distribution Unit with 12 x  5/15 sockets Round Pin, 230 Volts AC, 32  Amp with Plug, Vertical Cable Manager-27U-Loop, Horz. Cable Manager-1U-Loop, Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility maximizing the usable mounting space, Depth adjustable mounting slots, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with pretreatment process meeting all industry standards, Grounding and Bonding Options can be provided, 100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment, Conforms to DIN 41494 or equivalent standard, Welded  Frame, Lockable Toughened Glass Door, Metal Vented Door Steel, DIN Standard 10mm Sq. Slots / Direct M6 Tap, 19” Mounting angles made of formed steel Powder Coated, Welded to Frame, Vented and Field Cable entry exit cut outs complete in all respects as approved and desired by the Engineer in-charge at site.

1

51586

51586

... More
Supply, erection, testing & commissioning of HDD Formatted capacity 6 TB, Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s, Cache (MB) 64, Rotational speed (RPM) IntelliPower, Load/unload cycles4 300,000, Non-recoverable read errors per bits read 1 in 1014,Operating (2 ms, read/write) 30,Operating (2 ms, read) 65, Non-operating (2 ms) 250,Average power requirements (W) Read/Write 5.90, Idle 4.90, Standby and Sleep 0.40 complete in all respects as approved and desired by the Engineer in-charge at site.

3

75711

25237

... More
Supply, erection, testing & commissioning of Display : 50 inch, 4K (3,840 x 2,160), Direct LED, Professional Display with 4K Processor, Native Contrast ratio 5,000:1 or higher, Response time 12 ms or lower, Brightness 400 cd/m² or higher, 24/7, Portrait/Tilt functionality, HDMI Auto wake up, HTML5 platform, 16GB On Board Storage, HDMI*4 with HDCP 2.3 / RS232 / USB / RJ45 / Wi-Fi Direct / 20W Speakers / Android OS or similar, Viewing angle 178 degree, Apple AirPlay & Chromecast.complete in all respects as approved and desired by the Engineer-in-charge at site.

1

93745

93745

... More
Supply, Installation, Testing & Commissioning of Category 6 UTP, 4 Pair This cable well exceeds the requirements of TIA/EIA-568-C.2 and IEC/ISO 11801. Construction: 4 twisted pairs separated by cross separator, 4 channel, polymer spine / full separator. Half shall not be accepted, Operates at bandwidth of 250 MHz, Conductor Solid Bare Electronic Grade Copper. Inner jacket should be PVC and outer should be PE, suitable for direct burial. Insulation: Polyethylene, Attenuation ( 36 db/100m), Pair – to – pair and PS NEXT, ELFEXT and PSELFEXT, Return Loss, ACR and PS ACR., Nominal Outer Diameter of Cable should be 9.70 mm and Conductor Diameter 0.56 mm (23 AWG), Cable should support operating Temperature from -20° to +60°C, Cable should come with printed sequential Length Counter on each meter, Cable support Conductor Resistance 93.5 OHMS/1000MTR@20 Degree, Mutual Capacitance of cable should be 5.6nF/100m, Max Resistance Unbalance of cable should be 5% Max, Capacitance Unbalance of cable should max 330pF/100m, Cable support Delay Skew: 45nS, Operating Voltage: 72V and NVP: 69%, Shall Supports Gigabit Ethernet (1000 base-T) standard and Operates at bandwidth of 250MHz.complete in all respects as approved and desired by the Engineer in-charge at site.

1200

68400

57

... More
Supply, Installation, Testing & Commissioning of 6 Mtr HDMI Cable for NVR, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.

1

1959

1959

... More
Supply, Installation, Testing & Commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90% complete in all respects as approved and desired by the Engineer in-charge at site.

1

15539

15539

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-

-

-

-

... More
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed

1400

99120

70.8

... More
Total D6:

-

-

-

... More
Providing Fire Detection/ Emergency Evacuation & PA System:

-

-

-

... More
FIRE PANELS & ANNUNCIATORS:

-

-

-

... More
Supply, installation, testing & Commissioning of Microprocessor based 2-Loop True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event , 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature will offer Redundant CPU. Four access levels, flash EPROM, Panel should be capable to work 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall support with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus/ Bacnet over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable for remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab.complete in all respects as approved and desired by the Engineer in-charge at site.

1

366052

366052

... More
Supply, installation, testing & Commissioning of Inbuilt automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH with Emergency evacuation Control Panel & Digital Voice command system with Battery Dress Panel. The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.

1

59096

59096

... More
Supply, installation, testing & Commissioning of Paging Microphone compatible with Emergency evacuation Control Panel Project specific OEM authorization required for executing agency complete in all respects as approved and desired by the Engineer in-charge at site.

1

30030

30030

... More
Supply, installation, testing & Commissioning of Addressable Smoke/Multi-criteria Photo-Thermal Detector and base with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th Edition complete in all respects as approved and desired by the Engineer in-charge at site.

180

810180

4501

... More
Supply, installation, testing & Commissioning of Reponse Indicator for up side of ceiling complete in all respects as approved and desired by the Engineer in-charge at site.

46

40664

884

... More
Supply, installation, testing & Commissioning of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches complete in all respects as approved and desired by the Engineer in-charge at site.

1

4395

4395

... More
Supply, installation, testing & Commissioning of High Sensitivity early warning Photo Detector with sensitivity level of 0.02% to 2% Obs/Feet. The detector shall have the optic block to amplify signals from smoke, but diminish stray internal reflections that can cause false alarms. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th Edition complete in all respects as approved and desired by the Engineer in-charge at site.

2

58258

29129

... More
Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site.

14

68726

4909

... More
Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete in all respects as approved and desired by the Engineer in-charge at site.

28

141848

5066

... More
Supply, installation, testing & Commissioning of Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.

1

5066

5066

... More
Supply, installation, testing & Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.

15

63465

4231

... More
Supply, installation, testing & Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.

1

5269

5269

... More
Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.

12

72072

6006

... More
Supply, installation, testing & Commissioning of Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed. Project specified OEM authorization required for executing agency. The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site.

8

44488

5561

... More
Supply,installation, testing & Commissioning of Digital Audio Amplifier with cabinet & Amp power supply. Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of 100 W at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall (be Wall/Panel Mounted) not be rail mounted / dependant on Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of Amplifier operation. The Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers shall provide back up of minimum 5 hours using secondary power source(battery power/UPS power). .Executing agency should have project name specified OEM authorization on the time of supply and also have a minimum two OEM certified engineer for commissioning & programming complete in all respects as approved and desired by the Engineer in-charge at site.

1

192787

192787

... More
Supply,installation, testing & Commissioning of Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on the same peer-to-peer Network and 2 ways Communication capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. Products not having this feature must provide dedicated CPU for DVC. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. The panel shall be capable of self programming without any dependency on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for programming the panel with all necessary licence. Panel shall have Modbus/ Bacnet over IP protocol for future integration with BMS. However, for the present arrangement the FA system will be standalone with 24x7 monitoring. The panel shall be capable of remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th Edition. .Executing agency should have project name specified OEM authorization on the time of supply and also have a minimum two OEM certified engineer for commissioning & programming complete in all respects as approved and desired by the Engineer in-charge at site.

1

301892

301892

... More
Supply, installation, testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling/Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed. Project specific OEM authorization required for executing agency complete in all respects as approved and desired by the Engineer in-charge at site.

153

460989

3013

... More
Supply, installation, testing & Commissioning of Back box for speaker as per site requirement complete in all respects as approved and desired by the Engineer in-charge at site.

153

202419

1323

... More
Supply, installation, testing & Commissioning of fire resistance cable (Colour Red) (at 950° C for 180 minutes) of BS6387/BS7846 Fire Proof Cable, 2C X 1.5 sqmm, BS6387 & BS7846, annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanized steel wire armour, low smoke & zero halogen (LSZH) red outer sheath. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) complete in all respects as approved and desired by the Engineer in-charge at site.

1500

378000

252

... More
Supply, installation, testing & Commissioning of Exit LED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code complete in all respects as approved and desired by the Engineer in-charge at site.

11

163933

14903

... More
Supply, installation, testing & Commissioning of Agora LED NM LED IP65 230V 2X6W 1h/3h/8h. The luminiare comes in plastic housing. Mounting bracket is not required for this luminaire, IP65/NA 0 Non -Maintained Self Testing 12V / 7Ah Pb, LED based for anti-panic area, surface assembly Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch High lumen output – 1h = 360lm / 3h = 170lm / 8h = 70lm Simple and quick assembly and maintenance Technical lifetime of LED 100 000 hours • IP65 – dust and waterproof luminaire, Voltage 220-240VAC / 50-60Hz Power consumption 11.4W / 11.8VA Battery 12V / 7Ah Pb Battery protection Over charge protection /deep discharge protection Charging Time 23 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source LED 2x6, Technical lifetime (light source) 100 000 hours, Lumen output, emergency (1h / 3h / 8h) 3200 / 1600 / 800 lm, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IP rating IP65, Dimensions 302 x 94 x 210 mm, Weight 4200 / 4420 gr, Materials PC/ABS, PC, Aluminium, Mounting method Wall mounting, Make : Honeywell, Siemens / RP / Olampia / Adward.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab. complete in all respects as approved and desired by the Engineer in-charge at site.

9

448452

49828

... More
Supply, installation, testing & Commissioning of Online UPS 1 kva 800 Watts Tower UPS with 1 hour battery backup. Operating Temperature Range 0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter, Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No's, Rated Input Voltage 208/220/230/240 Vac, Maximum working input voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity, Rated kVA 1000 VA, Rated kW 800 Watts, Load type Resistive load/ lagging load/ non-linear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio 3:1, Online Efficiency 88%, Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available, Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available, Intelligent Fans Speed control Available, Auto restart function Available, Cold start Available complete in all respects as approved and desired by the Engineer in-charge at site.

1

41099

41099

... More
PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 1.5sq.mm (48/0.20mm), 2Core

1400

67102

47.93

... More
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-

-

-

-

... More
Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed

1200

169092

140.91

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-

-

-

-

... More
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed

1300

92040

70.8

... More
Total D7:

-

-

-

... More
Providing Nurse Call System :

-

-

-

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved System Switch: The system switch forms a decentralised communications node for exchanging data between the connected system devices and the rest of the communications system, consisting of : - 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX), galvanically isolated conforming to EN 60950 and VDE 0834; - 7 x RJ45 sockets, each for a 100Mb IP system port (IEEE802.3 100BaseTX) for connecting all IP capable system modules; - 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX) for connecting communications, staff and ward terminals as well as control panel PCs or for redundant Connection.- Control LEDs for indicating the current operating state, - 2 x RJ45 sockets for connection of the external data bus; - All IP system modules are supplied with power using Power over LAN technology complete in all respects as approved and desired by the Engineer-in-charge at site.

4

334460

83615

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved Nurse Station Terminal: Nurse Station shall comprises of minimum 7“ large touch screen LC colour graphic display for displaying all details , a smash proof glass panel (to protect the sensitive display from unnecessary contact during cleaning and other processes) , Querying receiver for speaking discretely, Microphone and loudspeaker for hands-free speech (incl. volume control), automatic changeover between hands-free and discrete speaking , Electronic circuit board with controller and FlashProm, 100BaseTX interface to the system switch, PC interface to the communications control panel , 2.8m connection cable with an RJ45 connection plug, which is protected, from disconnection, for connecting to a connection module . The ward terminal shall display date and time, indication of all presence, all set reminedrs, indication of all calls in accordance with VDE0834. All call indications follow the priority and must display the exact location of the calls. The ward terminal shall be provided along with suitable connection module & back box. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

778012

194503

... More
Supply, erection, testing & commissioning of 'Connection module for External monitor: VDVI Module - DVI output with inbuilt sounder to display nurse call on external monitor Module shall contain: • Connection of 2 DVI monitors • 2 DVI sockets for standard monitors with DVI input connection (computer TFT/LCD/ flat screen monitor) or a HD ready TV. On each device the same text is indicated. For TV devices without DVI input, a passive DVI / HDMI coupler can be used. HD video in format 720p60 • Galvanic isolated DVI outputs • built-in piezo buzzer for call signaling • LAN interface: RJ45 socket, 100Base-TX interface complete in all respects as approved and desired by the Engineer-in-charge at site.

6

335574

55929

... More
Supply, erection, testing & commissioning of External Monitor- To display call generation on external bigger display: Min. 21" LCD/ LED monitor of reputated make with mounting accessories having DVI input port (Incase DVI input not available in external monitor, DVI to HDMI convertor may be used for HDMI output). complete in all respects as approved and desired by the Engineer-in-charge at site.

6

154122

25687

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved Patient Handset - Without Speech: Non Speech Patient Hand set consisting of a plastic case in antimicrobial finish having - Call button with nurse symbol with integrated finder and reassurance light on the top end of the unit, - Membrane keypad in antimicrobial/ anti fungal finish with integrated LEDS for operation, consisting of: - 2 call key, - 2 lighting keys - 2.80 metre connection cable with auto-disconnecting RJ45 connector plug. It shall be supplied with cradel for holding patient terminals & necessary connection module. complete in all respects as approved and desired by the Engineer-in-charge at site.

55

575410

10462

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved connection module for Patient Terminal: Connection module for patient handset shall consist of: - 1 x RJ45 socket marked in colour and with measures to ensure that the push button is correctly connected, including auto disconnect mechanism, - 1 membrane keypad with: - 1 call button (red with nurse symbol) including a finder/reassurance light, - 1 presence key/ cancel button (green) including a control LED, - 1 DIN Socket for interfacing with other medical devices - should be connected in loop technology complete in all respects as approved and desired by the Engineer-in-charge at site.

55

1339855

24361

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved Patient Handset - With Speech: consisting of a plastic case in antimicrobial finish having - Call button with nurse symbol with integrated finder and reassurance light on the top end of the unit, - Membrane keypad in antimicrobial/ anti fungal finish with integrated LEDS for operation, consisting of: - Integrated loudspeaker and microphone for speech connections - Integrated LC display with position alignment - 2.80 metre connection cable with auto-disconnecting RJ45 connector plug. It shall be supplied with cradel for holding patient terminals & necessary connection module. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

89508

44754

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved Room Terminal with display: Terminal with acoustic and optical call forwarding, display, call and presence buttons. • Integrated LCD with backlight • Germ inhibiting membrane keypad with the following buttons: – Presence button (green) with status LED – Presence button (blue) with status LED – Call button (red) with locating and reassurance light – Doctor call button (blau) with reassurance light – Three function buttons complete in all respects as approved and desired by the Engineer-in-charge at site.

2

52900

26450

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved call & cancel Button - For WC: call cancel button for WC shall consist of: - 1 call button including a finder light & reassurance light, - 1 presence button (green) incl. control LED, - integrated finder lights or reassurance light - Moisture Protected - should be connected in loop technology. complete in all respects as approved and desired by the Engineer-in-charge at site.

10

90990

9099

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved Code Blue button - Doctor call-Cancel button for wards: 1 doctor call key (blue) including a finder light / reassurance light, - Doctor cancel button - a membrane keypad - Integrated sounder -2 RJ45 ports for loop connectivity - should be connected in loop technology. complete in all respects as approved and desired by the Engineer-in-charge at site.

14

203644

14546

... More
Supply, erection, testing & commissioning of VDE 0834 certified/ approved Loop Powered Lamp Module: For optical indication of calls, presences and reminders in the relevant colours conforming to VDE0834 consisting of: - 5 light chambers with light reflectors for homogeneous illumination, - 1 light chamber fitted with 3 ultra bright red LEDs, - 1 light chamber fitted with 3 ultra bright white LEDs, - 1 light chamber fitted with 3 ultra bright green LEDs, - 1 light chamber fitted with 3 ultra bright blue LEDs, - 1 light chamber fitted with 3 ultra bright Yellow LEDs, - 2 RJ45 ports for loop connectivity - the LED life expectancy is approximately 100,000 operating hours, - should be connected in loop technology.complete in all respects as approved and desired by the Engineer-in-charge at site.

15

139290

9286

... More
Supply, erection, testing & commissioning of Management center - Nurse Call Server: Networking, Software & Integration Management Centre Server for Nurse Call System for uploading the firmware and the system configuration, for operating interfaces to foreign systems, for logging of all system events and as a central location for system configuration and remote maintenance as per VDE 0834 - Intel Xeon 3220 2,4GHz or similar - 2 GB RAM, 1 x 160GB HDD - 1 x DVD harddrive, 2 x Gbit LAN Ethernet RJ45 - 1 x serial connection RS232 and 2 x USBV2.0 - 1 x PCI or 1 x PICe socket, support for SUSE Linux enterprise Server from V10.1 complete in all respects as approved and desired by the Engineer-in-charge at site.

1

488433

488433

... More
Supply, erection, testing & commissioning of Backbone Switch : Floor Switch: Uplink connections: 2 x 1Gb uplink ports, RJ45 (GBIC capable, possibility for LWL) Connections downlink: 16 x 100Mb downlink ports, RJ45 Switch must have all the function which is mentioned in the tender Document complete in all respects as approved and desired by the Engineer-in-charge at site.

1

132408

132408

... More
Supply, erection, testing & commissioning of Software- Event Database Software: Software pack installed on the system server for automatically logging all events in the entire communications system, such as, e.g., calls, presence markings,call acknowledgements, reminders complete in all respects as approved and desired by the Engineer-in-charge at site.

1

299170

299170

... More
Supply, erection, testing & commissioning of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable 305 mtr per Box. Blue in colour conforming to the following standards like ANSI/TIA 568 C.2, EN50173, IEC 11801 2nd ED, 700Mhz etc. in Cat 6 U/UTP LCS2 cable with 23AWG.Complete in all respect to the entire satisfaction of the engineer-in-charge including 3 Year Warranty on site Service Support. complete in all respects as approved and desired by the Engineer-in-charge at site.

1000

57000

57

... More
Supply & Laying of Wall Mount 15U x 600 W x 600 D , Front Glass Door (tinted, Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC. as per DIN 41494 Standards including 3 Year Warranty.complete in all respects as approved and desired by the Engineer-in-charge at site.

1

13378

13378

... More
PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 1.5sq.mm (48/0.20mm), 2Core

300

14379

47.93

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-

-

-

-

... More
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed

800

56640

70.8

... More
Total D8:

-

-

-

... More
Providing UPS System 60KVA with isolation transformer (30 Min. Back-up):

-

-

-

... More
Supply, Erection, Testing & commissioning of 60 KVA IGBT based Online UPS 60000 VA / 48000 watt 3 phase input 3 phase out put for approx 30 min backup (Special Features:-Advanced Microprocessor Control, LCD Display on front Panel, 0.9 Power Factor (60000 VA / 48000 watt), Can be mounted in a Server Rack, Can be Mounted in Parrallel Mode, Heavy Duty Charger upto 13amp, Dual Input Supply available, Extra Wide Input Voltage Range, Input Power Factor Correction, Sine-Wave Output, EMI/RFI Filters & Surge Protectio, Self Diagnostic & Battery Tests, Intelligent Battery Management, User-friendly Panel with Load & Battery Bar-Graphs, Power Chute Software for UPS Power Management & Diagnostics compatible to, Windows, Novell & Unix (Automatic PC Shut down Software), 32/34 nos.100ah Battery, Rack for Battery, Battery interconnecting cables, cables between UPS and Battery and Battery circuit breaker as approved & desired by the Engineer in charge at site. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

2798066

1399033

... More
Total D9:

-

-

-

... More
Providing Silent Diesel Generating Sets: For Main Building: 1No. 250KVA DG Set with AMF panel For HVAC Load of the Building: 1No. 250KVA with AMF Panel

-

-

-

... More
Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 250 KVA /200KW with AMF Control Panel .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing 310 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV Norms as amended upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.

-

-

-

... More
ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site: AMF PANEL: AMF panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Microprocessor based release) /ACB (Overcuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger. MCCB 4 Pole 400A 35kA microprocessor based release: 2Nos. Power Contactor 4 pole, AC-3 duty of suitable rating : 2 Nos. Digital Multifunction Meter to show, KW, KWH, KVAH, P.F. and frequency, CL-1, etc:1 No. "R, Y, B' LED indicating lamps & "ON / OFF" LED indicating lamps Over Voltage relay & Under Voltage relay Battery charger (with trickle and boost charging): 1 Set. 8 window Alarm annunciator with separate hooter, accept, reset and rest push button:1No. The model of engine will be decided by the Engineer in Charge. The Generator set should be installed at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge.

2

6817198

3408599

... More
INDOOR LT CABLES, CABLE TRAY & DWC PIPE:

-

-

-

... More
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-

-

-

-

... More
Overall size 120sq.mm (3½ Core) Un-armoured (Loose) 2Runs from DG Set 250KVA to AMF Panel for 2Nos. DG Set Seprately

400

234404

586.01

... More
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- (From DG Set to AMF Panel)

-

-

-

... More
Overall size 2.5sq.mm (10 Core)

200

70668

353.34

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-

-

-

-

... More
Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)

180

28065

155.92

... More
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)

360

71679

199.11

... More
COPPER EARTHING

-

-

-

... More
COPPER EARTHING (Upto 14 metre in Length):- iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- (Body earthing & Neutral Earthing)

-

-

-

... More
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length) (Body earthing & Neutral Earthing: 2 x 4Nos. for DG Set 250KVA)

8

162569

20321.17

... More
Additional Length 25mm x 3mm thick Copper Tape

120

76459

637.16

... More
Total D10:

-

-

-

... More
Providing 11 KV Sub Station: For Main Building: 1No. 400KVA Transformer For HVAC Load of the Building: 1No. 315KVA Transformer

-

-

-

... More
VACUUM CIRCUIT BREAKER: NEAR MAIN GATE

-

-

-

... More
Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) switch board unit 630 Amp. which includes 630/800 Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of 25kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 100 opeartion

-

-

-

... More
VCB parameters are as below: (a). Rated Voltage: 12kV (b). Rated short circuit breaking current withstand : Min. 25kA for 3sec. (c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak (d). Rated insulation voltage( Power frequency withstand) : Min. 28kV (e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO (f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz) (g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) (h). Earthing Switch : Mechanically interlocked device to prevent personnel from getting electric shock during breaker maintenance. VCB incorporating mechanical as well as electrical ON/OFF indiaction "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door.

-

-

-

... More
Incomer shall consist of: (a). Cast Resin CT's 11kV : 600-300/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA (c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type (d). Master Trip/ Anti pumping relay (e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments.

-

-

-

... More
Outgoing shall consist of: (a). Cast Resin CT's 11kV : 600-300/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection (c). Master Trip/ Anti pumping relay (d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal (f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:-

-

-

-

... More
11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Switch board unit 630 Amp. which includes 1 No. 630 /800Amp. Vacuum Circuit Breaker as Incomer, 2Nos. Vacuum Circuit Breaker as Out going feeder with in built power packs interconnected with Electrolytic Copper bus bars of suitable rating (2Nos. 800 KVA Transformer).

1

1794617

1794617

... More
VACUUM CIRCUIT BREAKER: IN SUBSTATION FOR 2NOS. TRANSFORMERS 400KVA

-

-

-

... More
Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) switch board unit 630 Amp. which includes 630/800 Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of 25kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 100 opeartion

-

-

-

... More
VCB parameters are as below: (a). Rated Voltage: 12kV (b). Rated short circuit breaking current withstand : Min. 25kA for 3sec. (c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak (d). Rated insulation voltage( Power frequency withstand) : Min. 28kV (e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO (f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz) (g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) (h). Earthing Switch : Mechanically interlocked device to prevent personnel from getting electric shock during breaker maintenance. VCB incorporating mechanical as well as electrical ON/OFF indiaction "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door.

-

-

-

... More
Incomer shall consist of: (a). Cast Resin CT's 11kV : 600-300/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA (c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type (d). Master Trip/ Anti pumping relay (e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments.

-

-

-

... More
Outgoing shall consist of: (a). Cast Resin CT's 11kV : 600-300/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection (c). Master Trip/ Anti pumping relay (d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal (f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:-

-

-

-

... More
11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Switch board unit 630 Amp. which includes 1 No. 630 /800Amp. Vacuum Circuit Breaker as Incomer, 2Nos. Vacuum Circuit Breaker as Out going feeder with in built power packs interconnected with Electrolytic Copper bus bars of suitable rating (2Nos. 800 KVA Transformer).

1

1794617

1794617

... More
TRANSFORMER 400KVA: (1No. for Building Electrical Load)

-

-

-

... More
Supply, installation, testing and commissioning of 11KV/433V, 400KVA, Indoor/Outdoor type floor mounted Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor conforming to IS:1180 (As amended upto date) Level-2 & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV (c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C (f). Oil/ Winding temperature rise: As per IS:1180 (g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side (j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer testing labotatory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:-

1

1686932

1686932

... More
TRANSFORMER 315KVA: (1No. for Building HVAC & PH Services Load)

-

-

-

... More
Supply, installation, testing and commissioning of 11KV/433V, 315KVA, Indoor/Outdoor type floor mounted Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor conforming to IS:1180 (As amended upto date) Level-2 & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV (c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C (f). Oil/ Winding temperature rise: As per IS:1180 (g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side (j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer testing labotatory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:-

1

1329428

1329428

... More
APFC FOR 400KVA TRANSFORMER:

-

-

-

... More
Design, supply, installation, testing and commissioning of TTA APFC Panel of 120 KVAR capacity with 7% detuned reactor suitable for operation on 415 ± 5% Volt, 3 Phase, 50 Hz, Ac supply, having MPP type resin bounded static capacitors (without oil) of suitable rating complete with MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting (Ics = 100%) capacity panel, upto 12 step microprocessor based power factor controller relay capable to select the rating from 4Nos. x 10KVAR, 2Nos. x 15KVAR, 2Nos. x 25KVAR capcitor bank, current limiting contactors for each capacitors protected with suitable rating MCCBs of minimum 25 KA breaking capacity having thermal magnetic release for over load & short circuit protection, cooling fans for panel and digital multifunction meter, Class-1.0 with RS485 communication port indicating lights, earthing the panel etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part of 120 KVAR capacity, automatically as and when required. Capacity of static capacitor should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with1.6 mm thick CRCA sheet duly powder coated etc complete as per PWD specification complete as per satisfaction of the Engineer in charge at site.

1

503735

503735

... More
APFC FOR 315KVA TRANSFORMER:

-

-

-

... More
Design, supply, installation, testing and commissioning of TTA APFC Panel of 100 KVAR capacity with 7% detuned reactor suitable for operation on 415 ± 5% Volt, 3 Phase, 50 Hz, Ac supply, having MPP type resin bounded static capacitors (without oil) of suitable rating complete with MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting (Ics = 100%) capacity panel, upto 12 step microprocessor based power factor controller relay capable to select the rating from 2Nos. x 5KVAR, 2Nos. x 10KVAR, 1No. x 20KVAR, 2Nos. x 25KVAR capcitor bank, current limiting contactors for each capacitors protected with suitable rating MCCBs of minimum 25 KA breaking capacity having thermal magnetic release for over load & short circuit protection, cooling fans for panel and digital multifunction meter, Class-1.0 with RS485 communication port indicating lights, earthing the panel etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part of 100 KVAR capacity, automatically as and when required. Capacity of static capacitor should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with1.6 mm thick CRCA sheet duly powder coated etc complete as per PWD specification complete as per satisfaction of the Engineer in charge at site.

1

391426

391426

... More
INDOOR MAIN LT PANELS : 1NO. FOR MAIN BUILDING & 1NO. FOR HVAC & PH LOAD

-

-

-

... More
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work .

-

-

-

... More
Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:-

-

-

-

... More
LT Panel enclosure having space for 1No. Incomer MCCB 630Amp. and 6Nos. outgoing MCCB's 40amp. to 250amp. (Option: MCCB 200-250amp.= 2Nos. and MCCB's 40-100amp.= 4Nos.) according to the requirement at site (Approx. size 1475 x 1800 x 400mm) (DETAIL SEE IN PANEL INVENTORY)

2

231796

115898.12

... More
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc

-

-

-

... More
MCCB Four Pole 63amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

2

15489

7744.7

... More
MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

2

22521

11260.86

... More
MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting

2

52049

26024.61

... More
MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting

3

105754

35251.58

... More
MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting

2

76753

38376.9

... More
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-

-

-

-

... More
MCB Four Pole 50, 63amp. (10kA, Curve-C)

3

5252

1750.76

... More
ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-

-

-

-

... More
On Load Change Over Switch Four Pole 400amp., 415volts

1

25352

25352.58

... More
On Load Change Over Switch Four Pole 630amp., 415volts

1

30081

30081.48

... More
HT CABLE, END TERMINATION KITS & CONTROL CABLE FOR TRANSFOMER:

-

-

-

... More
XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND): Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:-

-

-

-

... More
HT Cable Overall size 35sq.mm (3Core) (From Substation Room VCB to 2Nos. 400KVA Transformer & Metering Room VCB to existing Transfomer)

400

375720

939.3

... More
HT Cable Overall size 70sq.mm (3Core) (From PSPCL Meter to Metering Room VCB & Metering Room VCB to Substation Room VCB)

300

340956

1136.52

... More
XLPE INSULATED HT ARMOURED CABLES (LOOSE): Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- (From Metering Room to VCB & VCB to 2Nos. Transformers in Substation Room)

-

-

-

... More
HT Cable Overall size 35sq.mm (3Core)

100

56257

562.57

... More
HT Cable Overall size 70sq.mm (3Core)

100

75978

759.78

... More
S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:-

-

-

-

... More
Heat Shrinkable End Termination for cable size 35 sq. mm, 3Core (Indoor Type)

7

19420

2774.29

... More
Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Indoor Type)

3

9393

3131.21

... More
Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Outdoor Type)

1

3623

3623.83

... More
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- (From Substation VCB to 2Nos. Transformers 400KVA)

-

-

-

... More
Overall size 2.5sq.mm (10 Core)

200

70668

353.34

... More
INDOOR LT CABLES, CABLE TRAY & DWC PIPE:

-

-

-

... More
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-

-

-

-

... More
Overall size 16sq.mm (4Core) Un-armoured (Loose)

400

52676

131.69

... More
Overall size 50sq.mm (3½ Core) Un-armoured (Loose)

200

53202

266.01

... More
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)

200

73746

368.73

... More
Overall size 95sq.mm (3½ Core) Un-armoured (Loose)

450

203854

453.01

... More
Overall size 120sq.mm (3½ Core) Un-armoured (Loose)

300

175803

586.01

... More
Overall size 150sq.mm (3½ Core) Un-armoured (Loose)

300

208989

696.63

... More
Overall size 185sq.mm (3½ Core) Un-armoured (Loose)

100

86519

865.19

... More
Overall size 300sq.mm (3½ Core) Un-armoured (Loose)

100

135506

1355.06

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-

-

-

-

... More
Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)

380

59249

155.92

... More
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)

1030

205083

199.11

... More
Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.)

20

5815

290.77

... More
Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)

360

122878

341.33

... More
Double Walled Corrugated HDPE Pipe 180/152mm (Outer/ Inner dia.)

80

34133

426.67

... More
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-

-

-

-

... More
Cable Tray Size 300mm x 50mm x 50mm (2mm thick)

20

29114

1455.73

... More
S/E of LT Cast Resin type/ Heat Shrinkable Termination Kit for Outdoor/ Indoor supply of 1.1 KV grade PVC/XLPE cable as desired by the Engineer in charge of the site:-

-

-

-

... More
Heat Shrinkable Outdoor/ Indoor End Termination Kit for Cable Size 3½/4 Core 225-300sq.mm

8

20455

2556.95

... More
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-

-

-

-

... More
Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm

20

2604

130.21

... More
Brass Gland for Aluminium cable 2/3/3½/4 Core size 50sq.mm

8

1436

179.52

... More
Brass Gland for Aluminium cable 2/3/3½/4 Core size 70sq.mm

4

763

190.89

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 95-120sq.mm

20

5031

251.58

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 150sq.mm

6

1759

293.29

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 185sq.mm

6

2085

347.66

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 300sq.mm

10

5145

514.53

... More
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-

-

-

-

... More
Aluminium thimble cable Core size 10 -16sq.mm

30

442

14.75

... More
Aluminium thimble cable Core size 25 -35sq.mm

10

179

17.91

... More
Aluminium thimble cable Core size 50sq.mm

20

568

28.44

... More
Aluminium thimble cable Core size 70sq.mm

10

316

31.61

... More
Aluminium thimble cable Core size 95sq.mm

50

1843

36.87

... More
Aluminium thimble cable Core size 150sq.mm

20

1095

54.78

... More
Aluminium thimble cable Core size 185sq.mm

20

1306

65.32

... More
Aluminium thimble cable Core size 300sq.mm

20

2444

122.21

... More
COPPER EARTHING

-

-

-

... More
COPPER EARTHING (Upto 14 metre in Length):- iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-

-

-

-

... More
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)

8

149307

18663.38

... More
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)

14

284496

20321.17

... More
COPPER EARTHING (Upto 23 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 19.50 metre (63.96 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 23metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 18metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-

-

-

-

... More
Earthing with 40mm x 5mm Copper Tape (upto 23Metre in Length)

4

206468

51617.08

... More
Additional Length 20mm x 3mm thick Copper Tape

160

82830

517.69

... More
Additional Length 25mm x 3mm thick Copper Tape

280

178404

637.16

... More
Additional Length 40mm x 5mm thick Copper Tape

80

130499

1631.24

... More
SUB STATION SAFETY EQUIPMENTS:

-

-

-

... More
Supply of Rubber hand gloves suitable for 11KV.

2

1562

781

... More
Supply & fixing of shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.

2

244

122

... More
Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

10

1000

100

... More
Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

10

770

77

... More
Providing and fixing of Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity.

4

28288

7072

... More
Supply and fixing of foam fire extinguishers, Portable type 9 Litre capacity hanged on wall with bracket component as required.

4

15968

3992

... More
Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.

1

4729

4729

... More
Supply of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -1963

1

1496

1496

... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.

6

13470

2245

... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.

6

19548

3258

... More
Total D11:

-

-

-

... More
Providing Flood Lighting:

-

-

-

... More
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 1.5sq.mm (Un-sheathed)

200

4930

24.65

... More
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (For Flood Lights)

-

-

-

... More
Overall size 10sq.mm (3Core) Un-armoured (On-Surface)

250

26995

107.98

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-

-

-

-

... More
Double walled corrugated (DWC) HDPE pipe 63/51mm (outer/ inner dia.)

100

15592

155.92

... More
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:

-

-

-

... More
Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x 5mm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint. (For Flood Lights on Parapet wall)

12

16035

1336.26

... More
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-

-

-

-

... More
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement (For Flood Lights on Parapet wall).

12

10164

847.01

... More
GALVANIZED IRON PIPES AND G.I. EARTHING: Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). (For Cubical Pedestal)

-

-

-

... More
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length)

2

6631

3315.89

... More
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface)

10

1843

184.36

... More
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-

-

-

-

... More
Brass Gland for Aluminium cable 2/3/4 Core size 10sq.mm

30

3147

104.93

... More
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-

-

-

-

... More
Aluminium thimble cable Core size 10 -16sq.mm

40

590

14.75

... More
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-

-

-

-

... More
Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm

1

12641

12641.37

... More
SWITCH DISCONNECTOR FUSE UNIT (With Sheet Enclosure):- Supply and erection of Switch Disconnector Fuse Unit with HRC Fuses (Suitable for DIN HRC Fuses) in sheet enclosure on the existing surface Confirms to IS 13947 (Part-III), IEC 60947-3 complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles, including cost of DIN HRC fuses as per PWD General Specifications:-

-

-

-

... More
SDF TP&N 32Amp., 415volts (With Sheet Enclosure)

1

4150

4150.37

... More
TIMER:- Supply and erection of Switch S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:-

-

-

-

... More
Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)

1

15361

15361.08

... More
Supply and erection of LED Flood Light 120 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.

12

122940

10245

... More
Supply and erection of LED Post top 40/35 Watt with IP 65 protection (including LED driver) having efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021

2

14038

7019

... More
Providing Solar Power Generation System:

-

-

-

... More
Grid interactive PV System Solar Power Plant of 62KWp:

-

-

-

... More
Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimumcapacity including required quantities of SPV modules (High power density Monocrytalline based single module of capacity +400 watt) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. Features :- 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 14286 2. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529 3. Structure 25 Years service life with AMC & certified under IS 2062 2011 4. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material) 5. Annual Maintenance contract for the period of 5 Years Conditions: # The Plant will be installed as per MNRE and GOI guidelines and specifications. (Detail of material as per Annexure-I attached) #The work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor #The capacity of solar power plant my increase or decrees as availability of site it can also be totally removed from executive end The Rate are inclusive of all taxes including GST

62

3500706

56463

... More
Povision fo Cultural Cess on Gross Amount

152287013

1522870

0.01



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.