If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 1,13,000Document Cost
₹ 5,000Tender Fee
₹ 5,900
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEPW_119715_1Bid Award Id
ViewTender No
Bid No 81 Dt.06-03-2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwdpunjab.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
28.06
154050
5490.05
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position.
80.5
858236
10661.32
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
262.15
6627
25.28
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
262.15
18227
69.53
Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge
663
309780
467.24
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications as per CSR 24.5(a)
1027.48
333396
324.48
Fine grassing including uprooting rank vegetation and weeds by digging the area to a depth of 30 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days, mixing fertilizer and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, watering, weeding and maintenance for 30 days or till thick lawn is formed. a( Planting Selection no. 1 grass roots in rows 5 cm apart in both directions as per csr 32.9 a
5400
392526
72.69
Maintenance of fine grass lawn for one year including fertilizer application, watering, weeding, top dressing with good earth and manure mixture, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads. as per csr 32.10
5400
278748
51.62
P/F Football Pole made of MS Standerd size and black color polyester net complete in all respects
2
40000
20000
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
96
18407
191.74
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete
mixer volumetric type
7.2
29404
4083.93
CC 1:2:4 with stone ballast
14.4
81280
5644.5
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position.
36.67
390950
10661.32
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
223.92
5660
25.28
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
223.92
15569
69.53
Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge
366
171009
467.24
Providing & fixing Gymnastic Materail complete in all respects as per specification and as desired by engineer in charge
210
108990
519
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerincharge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
223.05
48406
217.02
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
2.75
29318
10661.32
Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
37.17
30594
823.1
Providing & fixing Water Sprinkler System in Ground complete in all respects as per specification and as desired by engineer in charge
1
562771
562771
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
-
-
-
Overall size 1.5sq.mm (48/0.20mm), 3Core
500
33555
67.11
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
-
-
-
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
-
-
-
Overall size 10sq.mm (2Core) Un-armoured (Loose)
1100
84018
76.38
Overall size 16sq.mm (4Core) Un-armoured (Loose)
150
19753
131.69
G.I. EARTHING: Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
-
-
-
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length)
2
6631
3315.89
Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-
-
-
-
GI Earth rod 20 mm dia., 3 mtr. Long
10
12747
1274.74
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
-
-
-
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
-
-
-
MCB Single Pole 6-32amp. (10kA, Curve-C)
40
7623
190.58
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
-
-
-
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
-
-
-
SP&N Double Door Distribution Board 4 way each
10
11012
1101.28
SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS):
-
-
-
Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:-
-
-
-
Bus Bar Chamber 63amp., 415volts Overall Dimensions (300mm x 345mm x 120mm) nominal
1
5025
5025.2
MCCB's (MOULDED CASE CIRCUIT BREAKER):
-
-
-
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
-
-
-
MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
1
6626
6626.73
MS SHEET ENCLOSURE FOR MCCB's:
-
-
-
Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
-
-
-
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
1
3342
3342.12
ROUND BRACKET OF 5' (5 FEET) DIA.:- Supply and erection of G.I. Pipe 50mm dia. (Medium) Round bracket to make a ring of 5' (5 feet) dia. (1.52 metre long) with 3nos. inclined member 3' (3 feet) long welded with MS canopy 125mm inner dia., outer dia 140.8mm (medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 114.3mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½" x 1½" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 140.8mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at an angel according to the size of ring inclination with MS sheet 5mm thick triangular in shape having dimensions 375mm x 150mm x 5mm thick with two coats of an approved aluminium paint as desired by Engineer-in-charge at site.
10
90321
9032.18
3-STEPPED STEEL TUBULAR POLE:- Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP-Mpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required:-
-
-
-
Overall length 11 metre, with planting depth 1.8 metre, length of sections 5.6 metre, 2.7 metre and 2.7metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 165.1mm x 5.4mm, 139.7mm x 4.5mm and 114.3mm x 3.65mm (Bottom, Middle and Top respectively) with approximate weight 194 kg. (410 SP-54) base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia.
10
238586
23858.61
Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's). The SMC Junction Box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of white snowcem complete in all respect as approved and desired by the Engineer In-Charge at site:-
-
-
-
Cement Concrete Muff of Overall Size 600mm dia., 80cm Long
10
22070
2207.08
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
-
-
-
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
-
-
-
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
1400
187306
133.79
Supply and erection of LED Flood Light 250watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
40
903520
22588