Public Works Department Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Public Works Department - PWD Tender

Eprocure
Opening Date31 Aug 2020
Closing Date11 Sep 2020
Tender Amount₹ 84,71,062 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 1,69,421
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 5,900

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85kg/sqm complete as per technical clause 502 of MORT&H specifications

4420

-

32.81

... More
Providing and applying tack coat with penetration grade bitumen VG- 10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications

19840

-

15.67

... More
Providing and laying dense graded bituminous macadam (grading-II) 50mm to75mm thick with continuous type HMP using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.5%, carriage of mix material to site of work laying with a paver finisher mechanical control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 505 of MORT&H specifications NOTES : - (i) Job mix formula for the dense bituminous macadam shall be provided by the agency and shall be got approved from Punjab PWD, B&R Research Laboratory Patiala before adoption at site for execution. (ii) The specification of this item for analytic purpose is kept with bitumen content @ 4.50% weight of mix variation as compared with job mix formula shall be paid / deducted accordingly. The limits of variation shall be worked out with the approved formula. TECHNICAL NOTE : - i.) Apart from the confirmity with the grading and quantity requirement of invidual ingredients exhibited above the mix aggregate i.e.coarse and fine aggregate for dense bituminous concrete shall meet all requirements set forth clause 505 of MORT & H specifications. ii) The final grading for the aggregates required for dense bituminous macadam confirming to table 500.10 of MORT & H specifications shall be determined after getting the dense bituminous macadam designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60 % of material. The design mix so finally approved shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set fourth in table 500-6 (addendum to latest revision). iii) The approved mix shall exhibit the following details, source and location of all material: - (a) Binder expressed as percentage by weight of total mix. (b) Course expressed as percentage by weight of total mix. (c) Crushed bajri expressed as percentage by weight of total mix. (d) Fine aggregate expressed as percentage by weight of total mix (e) A single definite percentage passing each sieve for mixed aggregates. (f) Density of dense bituminous macadam after compaction will be not less than 2.30 gm/CC.

496

-

7014.4

... More
Providing and laying bituminous concrete (grading-ii) 30mm to 45mm thick with continuous hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.4%, carriage of mix material to site of work laying with a paver finisher mechanical to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of MORT&H specifications NOTES : - (i) Job mix formula for the dense bituminous macadam shall be provided by the agency and shall be got approved from Punjab PWD, B&R Research Laboratory Patiala before adoption at site for execution. (ii) The specification of this item for analytic purpose is kept with bitumen content @ 5.4% weight of mix variation as compared with job mix formula shall be paid / deducted accordingly. The limits of variation shall be worked out with the approved formula. TECHNICAL NOTE : - i.) Apart from the confirmity with the grading and quantity requirement of invidual ingredients exhibited above the mix aggregate i.e.coarse and fine aggregate for dense bituminous concrete shall meet all requirements set forth clause 507 of MORT & H specifications. ii) The final grading for the aggregates required for dense bituminous macadam confirming to table 500.17 of MORT & H specifications shall be determined after getting the dense bituminous macadam designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60 % of material. The design mix so finally approved shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set fourth in table 500-6 (addendum to latest revision). iii) The approved mix shall exhibit the following details, source and location of all material: - (a) Binder expressed as percentage by weight of total mix. (b) Course expressed as percentage by weight of total mix. (c) Crushed bajri expressed as percentage by weight of total mix. (d) Final aggregate expressed as percentage by weight of total mix (e) A single definite percentage passing each sieve for mixed aggregates. (f) Density of dense bituminous macadam after compaction will be not less than 2.35 gm/CC.

297.6

-

7798.17

... More
Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications

98.12

-

606.83

... More
Cautionary sign board 900 x 900 x 900mm triangular as per IRC 67-2012 with high intensity microprismatic grade retro reflective sheeting type XI as per ASTM D 495609 and as per IRC 67-2012 fixed over 4mm thick aluminium composite material (ACM) sheeting having aluminimum skin thickness of 0.40 to 0.5mm on both sided and fixing the same with suitable size aluminium alloy riverts @ 200mm c/c to back support frame of 25x25x3mm angle iron supported on a mild steel angle iron post 65x65x6mm without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. A 10 years pre-qualification warrnaty as per clause 6.9 of IRC 67-2012 for TYPE XI retro reflective sheeting form the manufacturer & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 incluidng 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted.

2

-

5600

... More
Mandatory sign board 900 mm circular as per IRC 67-2012 with high intensity microprismatic grade retro reflective sheeting type XI as per ASTM D 495609 and as per IRC 67-2012 fixed over 4mm thick aluminium composite material (ACM) sheeting having aluminimum skin thickness of 0.40 to 0.5mm on both sided and fixing the same with suitable size aluminium alloy riverts @ 200mm c/c to back support frame of 25x25x3mm angle iron supported on a mild steel angle iron post 65x65x6mm without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. A 10 years pre-qualification warrnaty as per clause 6.9 of IRC 67-2012 for TYPE XI retro reflective sheeting form the manufacturer & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 incluidng 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted.

2

-

8286.17

... More
Place identification sign board 900x600 mm rectangular as per IRC 67-2012 with high intensity microprismatic grade retro reflective sheeting type XI as per ASTM D 495609 and as per IRC 67-2012 fixed over 4mm thick aluminium composite material (ACM) sheeting having aluminimum skin thickness of 0.40 to 0.5mm on both sided and fixing the same with suitable size aluminium alloy riverts @ 200mm c/c to back support frame of 25x25x3mm angle iron supported on two mild steel angle iron post 65x65x6mm firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. A 10 years pre-qualification warrnaty as per clause 6.9 of IRC 67-2012 for TYPE XI retro reflective sheeting form the manufacturer & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 incluidng 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted.

2

-

8962.75

... More
Advance Direction sign board 900x900 mm rectangular as per IRC 67-2012 with high intensity microprismatic grade retro reflective sheeting type XI as per ASTM D 495609 and as per IRC 67-2012 fixed over 4mm thick aluminium composite material (ACM) sheeting having aluminimum skin thickness of 0.40 to 0.5mm on both sided and fixing the same with suitable size aluminium alloy riverts @ 200mm c/c to back support frame of 25x25x3mm angle iron supported on two mild steel angle iron post 65x65x6mm firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. A 10 years pre-qualification warrnaty as per clause 6.9 of IRC 67-2012 for TYPE XI retro reflective sheeting form the manufacturer & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 incluidng 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted.

2

-

12916.8

... More
Nabard Board sign board 900x600 mm rectangular as per IRC 67-2012 with high intensity microprismatic grade retro reflective sheeting type XI as per ASTM D 495609 and as per IRC 67-2012 fixed over 4mm thick aluminium composite material (ACM) sheeting having aluminimum skin thickness of 0.40 to 0.5mm on both sided and fixing the same with suitable size aluminium alloy riverts @ 200mm c/c to back support frame of 25x25x3mm angle iron supported on two mild steel angle iron post 65x65x6mm firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. A 10 years pre-qualification warrnaty as per clause 6.9 of IRC 67-2012 for TYPE XI retro reflective sheeting form the manufacturer & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 incluidng 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted.

2

-

9000

... More
Citizen Information sign board 900x900 mm rectangular as per IRC 67-2012 with high intensity microprismatic grade retro reflective sheeting type XI as per ASTM D 495609 and as per IRC 67-2012 fixed over 4mm thick aluminium composite material (ACM) sheeting having aluminimum skin thickness of 0.40 to 0.5mm on both sided and fixing the same with suitable size aluminium alloy riverts @ 200mm c/c to back support frame of 25x25x3mm angle iron supported on two mild steel angle iron post 65x65x6mm firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. A 10 years pre-qualification warrnaty as per clause 6.9 of IRC 67-2012 for TYPE XI retro reflective sheeting form the manufacturer & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 incluidng 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted.

2

-

11000

... More
Advance Direction sign board 1200x1200 mm rectangular as per IRC 67-2012 with high intensity microprismatic grade retro reflective sheeting type XI as per ASTM D 495609 and as per IRC 67-2012 fixed over 4mm thick aluminium composite material (ACM) sheeting having aluminimum skin thickness of 0.40 to 0.5mm on both sided and fixing the same with suitable size aluminium alloy riverts @ 200mm c/c to back support frame of 25x25x3mm angle iron supported on two mild steel angle iron post 65x65x6mm firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. A 10 years pre-qualification warrnaty as per clause 6.9 of IRC 67-2012 for TYPE XI retro reflective sheeting form the manufacturer & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 incluidng 3 years outdoor weather exposure report for the retro reflective sheeting offered shall be submitted.

1

-

19834.67

... More
Reinforced cement concrete M-15 grade inary kilometre stone of standard design as per IRC 8-1980 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications

1

-

2836.26

... More
Add 1% Heritage and Cultural Cess 8387191

8387191

-

1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.