Public Works Department Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date21 Nov 2024
Closing Soon28 Nov 2024
Tender Amount₹ 74,75,951 
Notes
Download

Costs

  • EMD

    ₹ 1,49,519
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 5,900

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

51

221

11283.24

... More
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.Lintels. Total All floors

0.72

7097

5110.15

... More
Extra rate for First Floor

0.09

190

17.16

... More
Extra rate for Second Floor

0.09

381

34.32

... More
Extra rate for Third Floor

0.09

572

51.48

... More
Extra rate for Fourth Floor

0.09

762

68.65

... More
Extra rate for Fifth Floor

0.09

953

85.81

... More
Extra rate for Sixth Floor

0.09

1144

102.97

... More
Extra rate for Seventh Floor

0.09

1334

120.13

... More
Beams . Total All floors

19.92

7097

141380.81

... More
Extra rate for First Floor

2.49

190

474.79

... More
Extra rate for Second Floor

2.49

381

949.61

... More
Extra rate for Third Floor

2.49

572

1424.4

... More
Extra rate for Fourth Floor

2.49

762

1899.2

... More
Extra rate for Fifth Floor

2.49

953

2374.02

... More
Extra rate for Sixth Floor

2.49

1144

2848.81

... More
Extra rate for Seventh Floor

2.49

1334

3323.6

... More
Slabs . Total All floors

17.27

7097

122572.62

... More
Extra rate for First Floor

2.04

190

388.99

... More
Extra rate for Second Floor

2.04

381

777.99

... More
Extra rate for Third Floor

2.04

572

1166.98

... More
Extra rate for Fourth Floor

2.04

762

1555.97

... More
Extra rate for Fifth Floor

2.04

953

1944.98

... More
Extra rate for Sixth Floor

2.04

1144

2333.96

... More
Extra rate for Seventh Floor

2.65

1334

3537.17

... More
Extra rate for Eighth Floor

0.34

1525

518.66

... More
Walls . Total All floors

65.2

7097

462752.44

... More
Extra rate for First Floor

8.15

190

1554.04

... More
Extra rate for Second Floor

8.15

381

3108.17

... More
Extra rate for Third Floor

8.15

572

4662.21

... More
Extra rate for Fourth Floor

8.15

762

6216.25

... More
Extra rate for Fifth Floor

8.15

953

7770.37

... More
Extra rate for Sixth Floor

8.15

1144

9324.42

... More
Extra rate for Seventh Floor

8.15

1334

10878.46

... More
Columns . Total All floors

18.81

7097

133502.66

... More
Extra rate for First Floor

2.36

190

450

... More
Extra rate for Second Floor

2.36

381

900.03

... More
Extra rate for Third Floor

2.36

572

1350.04

... More
Extra rate for Fourth Floor

2.36

762

1800.04

... More
Extra rate for Fifth Floor

2.36

953

2250.07

... More
Extra rate for Sixth Floor

2.36

1144

2700.08

... More
Extra rate for Seventh Floor

2.36

1334

3150.08

... More
Centring and shuttering for Columns ( Square or Rectangular or ply gonal in plain). Total all floors

161.92

502

81368.04

... More
Extra rate for First Floor

18.88

10

199

... More
Extra rate for Second Floor

18.88

21

397.8

... More
Extra rate for Third Floor

18.88

31

596.8

... More
Extra rate for Fourth Floor

18.88

42

795.6

... More
Extra rate for Fifth Floor

18.88

52

994.6

... More
Extra rate for Sixth Floor

18.88

63

1193.4

... More
Extra rate for Seventh Floor

18.88

73

1392.4

... More
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. Total all floors

579.91

426

247430.2

... More
Extra rate for First Floor

67.24

10

708.71

... More
Extra rate for Second Floor

67.24

21

1416.75

... More
Extra rate for Third Floor

67.24

31

2125.46

... More
Extra rate for Fourth Floor

67.24

42

2833.49

... More
Extra rate for Fifth Floor

67.24

52

3542.2

... More
Extra rate for Sixth Floor

67.24

63

4250.24

... More
Extra rate for Seventh Floor

67.24

73

4958.95

... More
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.Total all Floors

142.48

560

79854.34

... More
Extra rate for First Floor

16.83

10

177.39

... More
Extra rate for Second Floor

16.83

21

354.61

... More
Extra rate for Third Floor

16.83

31

532

... More
Extra rate for Fourth Floor

16.83

42

709.22

... More
Extra rate for Fifth Floor

16.83

52

886.6

... More
Extra rate for Sixth Floor

16.83

63

1063.82

... More
Extra rate for Seventh Floor

21.86

73

1612.18

... More
Extra rate for Eighth Floor

2.81

84

236.83

... More
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.Total all Floors

165.12

400

66102.49

... More
Extra rate for First Floor

20.64

10

217.55

... More
Extra rate for Second Floor

20.64

21

434.88

... More
Extra rate for Third Floor

20.64

31

652.43

... More
Extra rate for Fourth Floor

20.64

42

869.77

... More
Extra rate for Fifth Floor

20.64

52

1087.32

... More
Extra rate for Sixth Floor

20.64

63

1304.65

... More
Extra rate for Seventh Floor

20.64

73

1522.2

... More
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.

6.43

5738

36897.91

... More
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. Total all floors

41.98

5882

246957.01

... More
Extra rate for First Floor

5.01

153

770.59

... More
Extra rate for Second Floor

5.01

307

1541.18

... More
Extra rate for Third Floor

5.01

461

2311.76

... More
Extra rate for Fourth Floor

5.01

615

3082.35

... More
Extra rate for Fifth Floor

5.01

769

3852.99

... More
Extra rate for Sixth Floor

5.01

922

4623.58

... More
Extra rate for Seventh Floor

5.01

1076

5394.17

... More
Extra rate for Eighth Floor

3.82

1230

4700.47

... More
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete.Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter.

3.66

527

1930.72

... More
12.5mm thick cement plaster 1:5.

321.04

197

63431.08

... More
Extra rate for First Floor

40.13

2

84.67

... More
Extra rate for Second Floor

40.13

4

168.95

... More
Extra rate for Third Floor

40.13

6

253.62

... More
Extra rate for Fourth Floor

40.13

8

338.3

... More
Extra rate for Fifth Floor

40.13

10

422.97

... More
Extra rate for Sixth Floor

40.13

12

507.24

... More
Extra rate for Seventh Floor

40.13

14

591.92

... More
20 mm thick cement plaster 1:5 in two coats work.

321.04

270

86860.58

... More
Extra rate for First Floor

40.13

2

84.67

... More
Extra rate for Second Floor

40.13

4

168.95

... More
Extra rate for Third Floor

40.13

6

253.62

... More
Extra rate for Fourth Floor

40.13

8

338.3

... More
Extra rate for Fifth Floor

40.13

10

422.97

... More
Extra rate for Sixth Floor

40.13

12

507.24

... More
Extra rate for Seventh Floor

40.13

14

591.92

... More
12.5 mm thick cement plaster 1:4.

223.86

206

46117.4

... More
20 mm thick cement plaster 1:4.

223.86

284

63634.44

... More
Extra rate for Smooth Surface of RCC Surface

102.84

56

5764.18

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.

31.09

265

8253.77

... More
Providing and fixing U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend

1

142

142.22

... More
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.

17

88

1504.33

... More
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.

1

110

110

... More
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.

1

739

739.08

... More
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating

1

87

87.87

... More
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing

16.65

789

13144.34

... More
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.

17.53

71

1258.48

... More
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres.

9.57

66

635.16

... More
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material

15.38

541

8334.73

... More
Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).

4.79

396

1899.43

... More
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material.Total all Floors

74.13

219

16262.64

... More
Extra rate for First Floor

10.59

3

33.46

... More
Extra rate for Second Floor

10.59

6

66.93

... More
Extra rate for Third Floor

10.59

9

100.39

... More
Extra rate for Fourth Floor

10.59

12

133.86

... More
Extra rate for Fifth Floor

10.59

15

167.32

... More
Extra rate for Sixth Floor

10.59

18

200.79

... More
Extra rate for Seventh Floor

10.59

22

234.25

... More
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :Total all Floors

76.24

1162

88635.86

... More
Extra rate for First Floor

9.53

3

30.11

... More
Extra rate for Second Floor

9.53

6

60.23

... More
Extra rate for Third Floor

9.53

9

90.34

... More
Extra rate for Fourth Floor

9.53

12

120.46

... More
Extra rate for Fifth Floor

9.53

15

150.57

... More
Extra rate for Sixth Floor

9.53

18

180.69

... More
Extra rate for Seventh Floor

9.53

22

210.8

... More
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing.Total all Floors

4.64

1413

6557.8

... More
Extra rate for First Floor

0.58

3

1.83

... More
Extra rate for Second Floor

0.58

6

3.67

... More
Extra rate for Third Floor

0.58

9

5.5

... More
Extra rate for Fourth Floor

0.58

12

7.33

... More
Extra rate for Fifth Floor

0.58

15

9.16

... More
Extra rate for Sixth Floor

0.58

18

11

... More
Extra rate for Seventh Floor

0.58

22

12.83

... More
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.Total all Floors

156.08

3460

540078.94

... More
Extra rate for First Floor

19.51

3

61.65

... More
Extra rate for Second Floor

19.51

6

123.3

... More
Extra rate for Third Floor

19.51

9

184.95

... More
Extra rate for Fourth Floor

19.51

12

246.61

... More
Extra rate for Fifth Floor

19.51

15

308.26

... More
Extra rate for Sixth Floor

19.51

18

369.91

... More
Extra rate for Seventh Floor

19.51

22

431.56

... More
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1) (1999) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick

0.98

2430

2381.81

... More
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm

0.98

116

114.6

... More
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm

1

209

209.65

... More
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.

83.47

130

10903.69

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete.Total all Floors

170.62

7876

1343958.38

... More
Extra rate for First Floor

17.56

13

240.57

... More
Extra rate for Second Floor

17.56

27

480.97

... More
Extra rate for Third Floor

17.56

41

721.54

... More
Extra rate for Fourth Floor

17.56

54

961.94

... More
Extra rate for Fifth Floor

17.56

68

1202.51

... More
Extra rate for Sixth Floor

17.56

82

1442.91

... More
Extra rate for Seventh Floor

18.17

95

1741.96

... More
Extra rate for Eight Floor

0.34

109

37.25

... More
Extra rate for using steel produced by primary producer such as SAIL/RINL/TATA/JINDAL complete in all respect as per the directions of Engineer-in-charge.

170.62

393

67099.73

... More
Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications.

32.92

4603

151557.1

... More
Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.

62.18

569

35438.87

... More
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.

102.84

297

30552.74

... More
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish

1090.14

84

91877

... More
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface

744.84

22

16475.86

... More
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)

744.84

93

69836.2

... More
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm

447.72

145

65089.53

... More
Construction of Plinth protection complete as per drawing. Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.

2.79

191

534.95

... More
Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type

0.56

4036

2260.62

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.

2.67

5821

15543.75

... More
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads.

1.39

389

541

... More
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material

8.78

541

4758.06

... More
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).

13.17

346

4557.08

... More
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.

5.85

197

1155.84

... More
ELECTRICAL SERVICES Providing Internal Electrical Installations: POINT WIRING: SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:-Wiring fan point (Without fan box)

8

1091

8733.52

... More
Wiring light point

16

762

12199.52

... More
Wiring 3 pin 6 Amp. wall socket point

1

618

618.93

... More
Wiring 3 Pin 6 Amp. Plug control comprising wall socket point

1

371

371.36

... More
Wiring 3 pin 16/20 amp. power plug control point

1

478

478.03

... More
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-

21

36

763.35

... More
Ceiling Rose (Flush Piano type).COPPER WIRES & CONDUIT PIPE: PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (Un-sheathed)

50

24

1232.5

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed

17

60

1027.99

... More
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed

30

70

2124

... More
XLPE INSULATED ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 25sq.mm (4Core) Armoured (Loose)

55

202

11154

... More
XLPE INSULATED ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Overall size 25sq.mm (4Core) Armoured (On-Surface)

48

225

10809.12

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.)

49

122

5988.29

... More
MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

2

7744

15489.4

... More
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan.

6

131

790.14

... More
MCB'S & MCB DISTRIBUTION BOARDS:SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- SP&N Double Door Distribution Board 4 way each

1

1101

1101.28

... More
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C)

2

190

381.16

... More
MCB Double Pole 6-32amp. (10kA, Curve-C)

1

580

580.27

... More
COPPER EARTHING :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 20X3 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long

1

11144

11144.34

... More
BONDING TO EARTH WITH COPPER WIRE:Bonding to existing earth with copper wire in heavy gauge (1.6mm thick) welded conduit pipe with bends, junction boxes, steel hooks and MS saddle clamps including painting etc.:-Bonding with copper wire 8S.W.G. (4mm dia) in HGW conduit pipe 20mm dia. (on surface)

20

206

4129.8

... More
LED'S FIXTURES & FANS:Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD 10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.

12

781

9372

... More
Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.

6

3564

21384

... More
Supply, Installation, Testing and Commissioning of 13 Passengers Lift 8 stop Machine Room Less. Type and Capacity : Approximately 884 Kg , 13 Passengers Speed: 1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Synchronous Electric Traction Gearless Motor to be hoisted on guide rail within the Elevator Hoist Way. Travel: Approximately 25 meter (Ground floor to 7th floor) Serving: 8 Floors 8 Stops 8 Openings 8 Levels (All on the same side) Hoist way : 2550mm (Wide) x 1800mm (Deep) Clear dimensions Headroom Height (HR): 4000 mm beyond finished floor level of last landing Pit Depth : 1600mm below the finish floor level of first landing Car Size Area: Minimum 2.06 Sqm and Maximum 2.20 Sqm Car Enclosure : Constructed out of stainless steel finish panel in Scratch Resistance/ Vandal proof Car Entrance: Center Opening Automatic Doors in Stainless Steel Panels in hairline Finish Scratch Resistance/ Vandal proof with Vision Panel (Upto 40% area should be visible by glass) having a clear opening of 900mm (wide) x 2000mm (high) and contrasting in colour from the adjoining wall.There should be no difference in level between the lift door and the floor surface at each level. The gap between the lift door and building floor should not be more than 12 mm.

-

-

-

... More
Hoist way Entrance: Ground to Seventh floor Panel Center opening Automatic Door's of Stainless steel finish panel in Scratch Resistance/ Vandal proof with provision of emergency key opening at landings with a clear opening of 900mm (wide) x 2000mm (high) Door operation : Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear)

-

-

-

... More
Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level and have a clear floor space minimum 900mmX1200mm Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level with no obstruction placed to prevent a wheelchair user from reaching it and have buttons with Braille/raised letters and in sharp contrast from the background to aid people with visual impairments Lift Signage: Signs indicating the location of an accessible lift should be provided in a location that is clearly visible form the building enterence. The sign should incorporate representation of the International Symbol for Access. A Sign indicating the number of the floor should be provided on each lift landing on the wall opposite the lift. It is also recommended to install a floor directory of the main facilities and services available on the lift landing, along with an accessible emergency egress route that clearly indicates the location of nearest refuge areas for Persons with Disabilities. Audio and Visual Indicators: The lift should have a voice announcement system along with a visual display to indicate the floor level and also the information that the door of the cage is open or closed for enterence or exit.The announcement system should be clearly audible.e. the announcement should be 50 decibel. Free service Two years after the S/I/T/C work and all std. Govt. features

-

-

-

... More
Other Features : 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13.Manual break lever 14. Additional car gate lock

-

-

-

... More
15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close. 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging

-

-

-

... More
27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28 The use of visually and acoustically reflective wall surfaces should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairments. 29 The floor of the lift car should be slip resistant and have similar frictional qualitites to the floor of the lift landing to decrease the risk of stumbling. 30 The provision of a mirror on the wall of the lift car opposite the lift door is a positive aid to navigation for wheelchair users. It allows the wheelchair user to see if anyone is behind them and also to see the floor indicator panel. The mirror should not extend below 900 mm from the lift door to avoid confusing people with impaired sight. 31 The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids. 13 passenger lift to be provided, which allows easy maneuverability of wheelchair user.

1

2433600

2433600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.