Public Works Department Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date6 Feb 2025
Closing DateCancelled
Tender Amount₹ 71,83,485 
Notes
Download

Costs

  • EMD

    ₹ 1,43,670
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 5,900

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing & Fixing Roller Ventilation Blinds for Window

720

200

144000

... More
Painting two coat with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint.

104.51

67

7046.06

... More
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure

237.92

728

173319.96

... More
Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block.

118.96

15

1879.57

... More
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.

23.88

400

9559.88

... More
Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey.

11.94

10

125.85

... More
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.

2.73

7243

19775.06

... More
Extra for R.C.C/PCC. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey.

1.36

190

259.32

... More
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete

2.73

7876

21503.96

... More
12.5 mm thick cement plaster 1:4

237.92

208

49558.74

... More
20 mm thick cement plaster 1:4

237.92

287

68447.2

... More
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 161mm x 60mm with 40 mm wide double rebate weighing 4.05 kg per meter.

62.79

977

61360.27

... More
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1(1999) ) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 30 mm

24.71

2313

57166.34

... More
Providing & Fixing decorative high pressure laminated sheet 1mm SF thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.

54.37

1171

63693.91

... More
Providing & fixing Stainless steel ball bearing hinges of size 100x89x3mm ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

56

176

9911.44

... More
Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

28

90

2536.8

... More
Providing & fixing 6" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.

14

250

3510.22

... More
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm

12

192

2313.48

... More
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish.

475.84

84

40103.8

... More
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)

475.84

93

44614.76

... More
Carpenter (Ist Class) Shifting & Fixing of Front Office

5

465

2329.55

... More
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm 4mm thick or 10.78 Kg/ sqm

9.08

703

6389.96

... More
Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.

5

10410

52053.3

... More
Providing and fixing commercial plywood 18mm thick

69.09

1315

90910

... More
Providing & Fixing decorative high pressure laminated sheet 1mm SF thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.

69.09

1171

80938.24

... More
Commercial Hard wood such as Hollock

0.2

105495

21099.08

... More
Melamine polish two or more coats to give required finish including one coat of wood filler

6.02

993

5980.57

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.

3.12

5397

16840.23

... More
12.5 mm Cement Plaster in 1:4

18.58

208

3870.21

... More
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material

34.93

569

19898.57

... More
Electrical Works:- SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- Wiring fan point (Without fan box)

14

1114

15597.12

... More
Wiring light point

35

711

24888.85

... More
Wiring call-bell point

6

741

4448.4

... More
Wiring 6Amp. wall socket point

2

617

1235.22

... More
Wiring 6Amp. Plug control comprising wall socket point

14

395

5530.84

... More
Wiring 16/20Amp. power plug control point

6

501

3010.38

... More
SURFACE AIR CONDITIONER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of air conditioner supply terminal point on surface on wall etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2 Module), covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:- Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.

8

755

6047.12

... More
SURFACE COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points on surface on wall etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate, covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:- Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indiicator and 2Nos. blanking plate

12

1031

12373.32

... More
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed)

520

24

12818

... More
Overall size 2.5sq.mm (Un-sheathed)

480

36

17750.4

... More
Overall size 4sq.mm (Un-sheathed)

560

53

29909.6

... More
Overall size 6sq.mm (Un-sheathed)

60

73

4437.6

... More
Overall size 10sq.mm (Un-sheathed)

100

120

12052

... More
Overall size 16sq.mm (Un-sheathed)

20

187

3752.6

... More
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)

955

57

54931.6

... More
Heavy Gauge PVC Conduit Pipe 40mm dia. (On Surface)

30

110

3318.6

... More
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C)

48

190

9147.84

... More
MCB Triple Pole 50, 63amp. (10kA, Curve-C)

4

1325

5302.04

... More
MCB Four Pole 40amp. (10kA, Curve-C)

2

1531

3063.48

... More
MCB Four Pole 50, 63amp. (10kA, Curve-C)

2

1750

3501.52

... More
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- TP&N Horizontal Double Door Distribution Board 4 way each

4

2914

11659.72

... More
HEAVY GAUGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.

14

131

1843.66

... More
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- Call Bell 220/230 volts AC Ding Dong

6

132

792.36

... More
Supply & erection of PVC Casing 'n' Capping (Double Lock) ISI marked for wiring purposes including cost of bends (L), (U), (T) & inspection boxes etc., where necessary including other petty material:- PVC Casing 'n' Capping Size 25mm x 16mm

20

41

821.8

... More
Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD 10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary.

3

820

2460

... More
Supply and erection of Recessed Mounted 36 Watt LED 2x2 panel (including constant LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD 10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary.

24

3924

94176

... More
Supply and erection of Slim Recessed mounted, Round downlighter 15 watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with CRCA sheet with control gear (IP 20 protection), THD10%, CRI minimum 70, Low power LED with wattage Less 1 Watt, Surge Protection 2.5KV and above as per IS/ IEC Standards, efficacy of LED fixture minimum 100 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.

4

1592

6368

... More
Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.

14

3564

49896

... More
Supply and erection of Wall Fan Plastic Body 400MM, 16" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.

2

3429

6858

... More
Supply and erection of Plastic Body 250MM, 10" Ventilation Fan including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.

2

1769

3538

... More
Supply, Installation and Commissioning of Distribution Switch 24 port L2 Switch with 2 Uplink 1G ports 2 copper Physical Specifications 24 # 10/100/1000 Base-T auto-sensing ports, 02 # 100/1000/10GBASE-T RJ45 Ports. 02 # 1000/10GBASE-X SFP+ ports. 1 RPS Connector, 1 USB Storage (Image. config.log files). CPU/Memory CPU 800 MHz, RAM. 512 MB. Packet buffer memory 32 MB, Flash 128 MB, Performance Specification Stack height 6 switches, Bandwidth 128 Gbos non-blocking, Throughput 95.2 Mops. Acoustic noise (ANSI-S10.12) 40dBA, Mean Time Between Failures (MTBF): 278,559 hours, MAC Address database size. 16,000 media access control (MAC) •addresses, 32 Static Routes, 8K DHCP snooping bindings. 512 ARP Cache entries, 8K DHCP snooping bindings, 100 shared for MAC, IP and IPv6 ACLs, Jumbo frame. 9K, IEEE Network Protocols. IEEE 802.3i 10BASE-T IEEE 802.10 VLAN Tagging. IEEE 802.1Qav1 IEEE 802.3z Gigabit Ethernet 1000BASE-SX/LX, IEEE 802 3ae 10-Gigabit Ethernet Over Fiber (10GBASE-SR, 10GBASE-LR, 1 GBASE-ER, 1GBASE-LX4) , IEEE 802.3ad Trunking (LACP), IEEE 802,3an 10GBASE-T 1 Gbitls Ethernet Over Copper Twisted, IEEE 802.1D Spanning Tree (STP), IEEE 802.1s Multiple Spanning Tree (MSTP) , IEEE 802 1w Rapid Spanning Tree (RSTP), IEEE 802.1x RADIUS Network Access Control, Power Consumption When all ports used Line-Rate Traffic. 28.18W Network Security and Traffic. Guest VLAN, Access Control Lists (ACLs) L2 / L3 / L4, Broadcast, Unicast Multicast Protection, IP-based ACLs (IPv4 and IPv6). MAC-based ACL MAC lockdown by the number of MACs, IEEE 802.1x Radius Port Access Authentication Port Scanty, QUALITY OF SERVICE (005) Access Lists. L2 MAC, L3 IP and L4 port ACLs, Port-based rate limiting Egress only, Port-based QoS, Support for IPv6 fields. DiffSery QoS, DiffSery QoS, IEEE 802.1p COS Destination MAC and IP, WRR (Weighted Round Robin), Strict pointy queue technology, Audio Video Bridging Systems (IEEE 802 IBA). L2 SERVICES — VLANS IEEE 802.1Q VLAN tagging, Auto-Voice VLAN • Based on phones OUI bytes (internal database. or user-maintained) or protocols (SIP. H323 and SCCP). L2 SERVICES — AVAILABILITY IEEE 802.3ad — LAGs. Broadcast storm control, IEEE 802.1w Rapid Spanning Tree Protocol. BPDU guard Complete in all respect as desired by the engineer at site.

1

58911

58911

... More
Supply. Installation Testing and commissioning of CAT 6A Cable should be Unshielded uld twisted pair cabling system, TIA / EIA 568-C.2 Category Cabling System Conductors should be 24 AWG solid bare copper Network support should be ultrahigh speed data networks such as Gigabit Ethernet (1000 Base-T and 1000 Base-TX) and beyond Cable Should be ETL/UL Certificates are mandatory Frequency tested up to should be 600 MHz minimum. Impedance should be 100 Ohms + / - 15 ohms. Box Packing shoed be 305M Should be 25-year systems 'warranty, Warranty to cover Bandwidth of the specified and installed cabling system. and the installation costs Site Certificate Should be issued by OEM. Should be RoHS compliant. Complete in all respect as desired by the engineer in charge at site.

600

95

57000

... More
Supply. Installation and Commissioning of CAT 6A Patch Cord 1 Mtr Patch Cord Should be 4 Pairs 24 AWG copper cables The Outer Jacket should be LOW Smoke Zero Halogen 24 AWG stranded bare copper. Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2 Should be verified by ETL (ETL certificate to be enclosed with the Bid) UL listed (UL certificate to be provided along with the Bid) Should Have cross 'separator Standard length should be available 0.5M to 10M.Should be RoHS compliant. Complete in all respect as desired by the engineer in charge at site.

12

449

5388

... More
Supply, Installation and Commissioning of CAT 6A Patch Cord 2 Mtr Patch Cord Should be 4 Pairs 24 AWG copper cables The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper. Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2 Should be verified by ETL (ETL certificate to be enclosed with the Bid) UL listed (UL certificate to be provided along with the Bid) Should Have cross. separator Standard length should be available 0 5M to 10M Should Be RoHS compliant. Complete in all respect as desired by the engineer in charge at site

12

589

7068

... More
Supply. Installation and Commissioning of CAT 6A Patch Panel should be made of cold rolled steel Should conform to TIC / EIA 568-C 2 Component Compliant. Should terminate 24 UTP CAT 6 A (4 pair) Cables. Should confirm to EIA/TIA 568A wing Pattren.Each port Should be features the spring-loaded shutter. Should be prevents incomplete mating Should be protecting from dust and contaminants Should Be Front and rear port labelling as well as panel identification label. Should be Integral cable management shelf ensures bend radius compliance Operating Life should be minimum 750 insertion cycles. Should be RoHS compliant. Complete in all respect as desired by the engineer in change at site.

1

9538

9538

... More
Supply, Installation, Testing and Commissioning of CAT 6A UTP Keystone Jack with Phosphor Bronze with Nickel Plated, 50 micro-inch Gold plated on Plug Contact area, Phosphor Bronze with Tin plated. Complete in all respect as desired by the engineer in change at site

12

438

5256

... More
Supply, Installation, Testing and Commissioning of CAT 6A Face Plates with Shutter, ARC design in order to fit the wall perfectly, Label Holder Included. Complete in all respect as desired by the engineer in change at site

12

123

1476

... More
Supply, Installation, Testing and Commissioning of CAT 6A Intermission Outlet Back Box. Complete in all respect as desired by the engineer in change at site.

12

79

948

... More
Supply, Installation, Testing and Commissioning of CAT 6A RJ45 Connector with Fits 22-24 AWG Standards, IEC60603-7, ANSI/TIA/EIA-568-C.2 Reliable and fast connection, 50 micro-inch thick gold plating, Polycarbonate housing, Nickel plated copper shield. Complete in all respect as desired by the engineer in change at site

12

101

1212

... More
Supply, Installation, Testing and Commissioning of Wall Mounting Rack (9U, 600X500) Front Glass Door ((tinted Toughened) with Lock & Key, 2 pars of 19" Mounting Rails with U-Marking. Welded Side Walls, Min Accessories 1U Cable Manager (1). Hardware Packet (1 Pkt), 6 Socket 5 Amp Power Distribution Unit (1 No). as per DIN 41494. Complete in all respect as desired by the engineer in change at site

1

9257

9257

... More
Supply installation, testing and commissioning of 1 KVA UPS with input power factor -0.09, Output power factor - 0.8 OVCD inbuilt DC V 24v Efficiency: Above 90 %, Voltage range 140-300v AC, Frequency 50HZ +/-10%, Voltage 230 AC nominal, frequency (battery mode) 50HZ +/- 1HZ, transfer time 4-8 ms, Voltage mains AVR mode 230V AC normal, rating 1000VA ,Type sealed lead acid 12V,7.2 Ahx2, Recharge time- 4-6 Hrs, complete in all respect as desired by the engineer in change at site

1

7855

7855

... More
Supply and erection of 02 Pair 0.5mm PVC Dual sheathed Telephone Cable as per ITD Specification 113B complete in all respect as desired by the engineer in charge at site.

160

17

2720

... More
Supply and Erection of 10 pair 0.5M and unarmoured PVC/PIJF telephone cable manufactured as per ITD Specifications with up to date amendment complete in all respect as desired by the engineer in charge at site

20

69

1380

... More
Supply and Erection of 10 Pair distribution box fitted with 01no. Of 10 pair each modules in MS or polycarbonate box fabricated of 18 gauge MS/polycarbonate sheet power coated ms sheet and having locking arrangement complete in all respect as desired by the engineer in charge at site

1

3787

3787

... More
Supply and Erection of basic clip EPBT with HDF,Audio Visual Indication,Display for clip and compaitible with digital hybrid IP-EPABX system complete in all respect as desired by the engineer in charge at site.

2

1262

2524

... More
Supply and Erection of Handsfree Phone with clip and Display with Caller-ID with complete in all respect as desired by the engineer in charge at site.

2

1766

3532

... More
SURFACE TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring TV socket, Telephone socket and Networking socket points on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:- Wiring Telephone socket point RJ11 (one module)

4

273

1095.64

... More
Public Health Works:- Internal Sewerage System:- Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge)including cutting, jointing, wastage, but excluding cost of lead jointing. Single Socket Type A 110 mm o/d SWR UPVC pipe line laid complete

23

313

7215.56

... More
90 mm o/d SWR UPVC pipe line laid complete

20

268

5376.6

... More
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d pipes Single Tee With Door

2

236

472.64

... More
Single Tee

4

206

824.6

... More
Elbow 90 Degree (All side socketed)

3

162

487.71

... More
Vent Cowls

3

45

136.2

... More
Coupler

4

111

444.36

... More
P Trap/Floor Trap 110mm x 110mm

3

338

1015.14

... More
Nahani trap without jali 110mmx90mm

3

172

517.29

... More
For 90mm o/d pipes Single Tee

2

184

369.72

... More
Elbow 90 Degree (All side socketed)

6

119

714.54

... More
Vent Cowls

2

37

75.26

... More
Coupler

5

109

546.65

... More
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. M.S. Holder bats clamps for 100mm i/d H.C.I. pipes

10

217

2171.8

... More
Providing and fixing in position gully traps (GT) fixed in cement concrete 1:4:8 complete with Grating 150 mm x 150 mm , cover and frame clear opening 300 mm x 300 mm and out of side size 330 mm x 330 mm and chamber including cost of all bricks work in cement mortar 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50 mm. 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm

1

1930

1930.01

... More
Construction of brick masonry inspection chambers size as given below upto 0.60 etre average depth in 1:5 cement sandmortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal

1

6780

6780.33

... More
Internal Water Supply System:- CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. SDR 11 CPVC Pipe & fitting 20mm o/d

27

233

6296.13

... More
SDR 11 CPVC Pipe & fitting 25mm o/d

15

301

4515.6

... More
INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. SDR 11 CPVC pipes & fittings 25m o/d

20

238

4776.6

... More
SDR 11 CPVC pipes & fittings 32m o/d

30

324

9723.9

... More
Cutting holes up to 23 cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required. Through wall 11.43 cm thick

5

176

882.1

... More
Through wall 22.86 cm thick

5

251

1258.55

... More
Cutting holes upto 23cm square for pipes in floor and roofs of cement concrete, reinforced concrete or reinforced brick work and making good the same & finishing according to existing finish where required. Through floor or roof 19.00cm thick

5

168

842.2

... More
Providing, fixing and jointing G.I Union Couplings (of approved make with the approval of EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 20 mm i/d G.I. Union

4

158

635.6

... More
25 mm i/d G.I. Union

4

200

802.28

... More
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and base support for tank - Triple Layer Tanks

2000

11

22760

... More
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball 25 mm i/d

2

950

1901.96

... More
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. G.I. tank nipple 20 mm i/d

4

124

497.68

... More
G.I. tank nipple 25 mm i/d

4

198

795.28

... More
Construction of Platform for placing PVC Water Storage Tank with M-20,RCC, Brick Work and Plaster etc. of required size complete in all respect.

2

5445

10890

... More
Sanitary Installation :- Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.

2

5035

10071.46

... More
Providing and fixing jet spray with 2'-6" long PVC pipe with PTMT nut

2

381

762.74

... More
Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect.

2

3146

6293.6

... More
Providing and fixing C.P. brass Urinal Spreader Ocular-Regular complete with fittings for urinals complete.

2

460

920.76

... More
Providing and fixing partition for different type of urinals. Chittor Black Slabs 19-20mm thick marble partition size 375mm x 750mm

2

749

1498.08

... More
Providing and fixing in position CP brass bottle trap 32mm dia with 40mm seal of approved make (to the approval of Engineer-in-Charge) complete in all respects.

2

1182

2364.06

... More
Providing and fixing in position paper holders of approved make (to the approval of Engineerin- charge ) fixed in to wall with C.P brass screws complete in all respect. C.P. brass toilet paper holder

2

1141

2283.98

... More
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P brass towel ring

5

959

4798.7

... More
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. Double bowl Sink without drain board Overall size 1114 x 490 mm with bowl size 460x385x200mm including waste coupling

2

14549

29099.78

... More
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.

2

119

238.1

... More
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 4 pegs

2

482

965

... More
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer- in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 550 mm x 400 mm x 815 mm

2

3807

7614.7

... More
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer- in -charge) for wash hand basin complete in all respect. Vitreous chinaware standard white half pedestal for wash hand basin.

2

1543

3086.76

... More
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.

2

888

1776.2

... More
Providing and fixing in position C.P brass basin mixer without pop-up waste system with 450 mm long flexible hose of approved make (to the approval of Engineer-in-charge) instead of C.P. brass pillar tap complete in all respect.

2

2114

4228.74

... More
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mmx450mm

2

1263

2526.3

... More
Providing & Fixing in position C.P. Brass flange of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect.

19

66

1261.03

... More
Providing & Fixing in position stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect. C.P.brass 15mm Concealed stop cock with flange.

2

1268

2536.82

... More
C.P.brass 15mm Angle valve without flange

12

870

10442.28

... More
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut

13

183

2383.03

... More
Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge) fixed in with rawl plugs and C.P brass screws complete in all respect. CP brass Acrylic Shelf size 560mmx130mm

2

1758

3516.58

... More
Providing & Fixing in position 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect. C.P. brass Bib cock long nose/ long body without flange

4

1214

4858.76

... More
C.P. brass Bib cock foam flow without flange

2

966

1932.12

... More
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.

2

87

174.88

... More
Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. Vertical type 25 litre capacity water heater

2

13268

26536.92

... More
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer

1

32962

32962.96

... More
AUTOMATIC VOLTAGE STABLIZER:Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-Automatic Voltage Stablizer 4 KVA

2

5501

11002.76

... More
Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.

1

40226

40226.84

... More
Finishing Work:- Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material

13.01

424

5523.53

... More
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete

13.01

917

11937.98

... More
Providing and fixing 1st quality ceramic glazed wall tiles Matt/ Semi Matt/ Glosy/ Highly Gloss finish/ Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

86

837

72027.58

... More
12.5 mm thick Cement Plaster 1:4

40.13

199

7990.28

... More
Carriage:- Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Phillaur Sand (Av. Lead 167 Km) 0 to 167 km

0.64

654

419.01

... More
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Ghaghar Sand (Av. Lead 320 Km) 0 to 320 km

2.34

913

2138.22

... More
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Bajri (Av. Lead 320 Km) 0 to 320 km

1.3

913

1187.9

... More
Estate Sewrage:- Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 110mm o/d pipe

70

599

41946.1

... More
Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge)including cutting, jointing, wastage, but excluding cost of lead jointing. Single Socket Type A 110 mm o/d SWR UPVC pipe line laid complete

10

313

3137.2

... More
Excavation manualy in trenches with straight or Open cutting in a built up street / lanes having wall to wall width upto 3 meter for sewer and Manhols to full depth as shown in drawings, including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for treffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 metre, for all works other than connections to complete in all respects. for depth not exceeding 2 mtr. BGL In all classes is soil except rocky 125 x 0.75 x 1.10

57.75

235

13627.85

... More
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame com Inside size 75x120 cm and 120 cm deep

5

19004

95020.45

... More
Making soak pit 2.5mouter Diametre 3.0 metre deep 230mm thick 1:5 brick work honeycombwithbricksof IstClassandS.W. drain pipe 100mmDiametre, 1.8m long complete as per standard design. With F.P.S. bricks

1

23525

23525.71

... More
Excavation in Soil (any type) using Hydraulic Excavator CK 90 Excavation with hydraulic excavator of 0.9 cum bucket capacity including cutting trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts andcombind lead up to 30mtr

12.66

35

453.48

... More
Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type

0.16

4919

787.18

... More
Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type

0.42

3294

1383.6

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth

2.4

5281

12674.88

... More
Centering & Shuttering for flat surface such as suspended floor roofs linning chhajas slabs etc.

3.59

560

2012.05

... More
Shuttering for faces sides of slab slabs etc

0.63

221

139.37

... More
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.

0.27

6217

1678.8

... More
12.5 mm thick cement plaster 1:2 with rendering.

7.2

286

2063.16

... More
Cold twisted deformed bars for RCC work where not included in the complete

0.22

7920

1742.53

... More
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). 560mm i/d RCC man hole cover with frame as per ISI Medium Duty

1

1800

1800.43

... More
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x15x11.5cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.each

6

220

1321.08

... More
Carriage:- Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Phillaur Sand (Av. Lead 167 Km) 0 to 167 km

0.91

654

595.78

... More
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Ghaghar Sand (Av. Lead 320 Km) 0 to 320 km

0.19

913

173.62

... More
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Bajri (Av. Lead 320 Km) 0 to 320 km

0.79

913

721.88

... More
Air Conditioner:- Providing & installing & erection split type wall mounted invertor air conditioner 5 star mak:- Carrier, Hitachi, Voltas, Blue Star, Daikin or equilant with 4.00 KVA voltage stabilizer, MCB arrangement for installing out door units on terrace including inlet and outlet copper tubes with copper insulation drainage arrangement cable link between ID unit and OD units stand for OD and connection of concealing of copper pipes and drainage pipe with building and installing charges complete in all respects 1.00 tonne

8

50000

400000

... More
1.50 tonne

20

56500

1130000

... More
2.00 tonne

14

64900

908600

... More
Providing laying hard soft copper concealing of copper pipe of various dia as per requirement and wall thickness 0.80 mm insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall repairing the same within the building and installing charges complete in all respects.

336

823

276528

... More
Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 10 Kgf/cm2 25mm i/d

252

194

48968.64

... More
Fire Fighting Works:- Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 2 Kg. Capacity

6

1645

9875.94

... More
Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 2 Kg. Capacity

6

4852

29112.06

... More
Roof Top Rain water Harvesting System:- Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.200mm o/d pvc pipe of 4 Kgf. / sqcm For Storm water Line 200mm i/d UPVC pipe as per Detail attached

115.06

1054

121299.7

... More
250mm o/d pvc pipe of 4 Kgf. / sqcm For Storm water Line 250mm i/d UPVC pipe as per Detail attached

200.86

1612

323862.65

... More
160mm o/d pvc pipe of 4 Kgf. / sqcm For connection of Road gully and water line @ 6mtr. Each per road gully

126

680

85690.08

... More
Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects. For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky For Roof top Storm water Line

59.39

104

6194.38

... More
Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete. Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.. Depth upto 1.50 m B.G.L. (CSR 29.2 A (a))

62.37

87

5453.63

... More
Cement Concrete 1:8:16 with 40mm gauge stone aggregate. (CSR 10.6 bii)

8.61

3294

28363.84

... More
Cement Concrete 1:2:4 with stone ballast or shingle.(CSR 10.13a ii)

0.63

4919

3099.51

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. (CSR 11.5)

19.95

5281

105359.94

... More
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (CSR 10.15)

1.89

5428

10260.22

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete (CSR 18.18)

1.47

7920

11643.25

... More
12.5 mm thick cement plaster 1:2 (CSR 15.7)

68.04

224

15268.18

... More
Cement rendering on plaster 1mm thick (CSR 15.48)

68.04

62

4229.37

... More
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). (CSR 29.34 d (iv) 455 x 610 mm rectangular clear opening RCC man hole cover with Light duty

21

1386

29114.61

... More
Compacting original ground below road crust Loosening, leveling and compacting original ground up to a level of 500mm below road crust, mixed with water at OMC, levelled, graded and compacted in layers by rolling so as to achieve minimum dry density as given in Table 300-2 for sub grade construction as per technical clause 305 of MORT&H specifications

25.83

68

1768.84

... More
Construction of Haudi internal size 0.45mtr x 0.45mtr & 0.45mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x450 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete. Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.. Depth upto 1.50 m B.G.L. (CSR 29.2 A (a))

19.32

87

1689.34

... More
Cement Concrete 1:8:16 with 40mm gauge stone aggregate. (CSR 10.6 bii)

4.62

3294

15219.62

... More
Cement Concrete 1:2:4 with stone ballast or shingle.(CSR 10.13aii)

0.21

4919

1033.17

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. (CSR 11.5)

6.3

5281

33271.56

... More
12.5 mm thick cement plaster 1:2 (CSR 15.7)

17.01

224

3817.04

... More
Cement rendering on plaster 1mm thick (CSR 15.48)

17.01

62

1057.34

... More
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). (CSR 29.34 (c, iv) 450mm i/d RCC man hole cover with frame as per ISI

21

1234

25928.7

... More
Compacting original ground below road crust Loosening, leveling and compacting original ground up to a level of 500mm below road crust, mixed with water at OMC, levelled, graded and compacted in layers by rolling so as to achieve minimum dry density as given in Table 300-2 for sub grade construction as per technical clause 305 of MORT&H specifications

13.65

68

934.75

... More
RECHARGE WELL 8" (200mm I/D) Borewell Depth of 50 mtr. Boring with casing pipe for tube well in all soils excepth ordinary hard rocks requiring blasting including removing the casing pipe after the tubewell is lowered & tested equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc, complete in all respect Boring with 250mm id Housing Pipe (CSR 28.72 (c) upto 150mtr depth BGL From Bottom of Well

50

969

48472.5

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818-2010, including required hire and labour charges, fittings & accessories etc. all complete for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. (CSR 28.92 (c))

35

1905

66696

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. (CSR 28.93 (c))

14

2702

37837.52

... More
Supplying & Fixing of M.S pipe bail plug suitable for 200 mm dia UPVC casing pipe having thickness of socket as 12 mm ,lengthm100 mm & base plate of 8 mm thick completem in all respect. (CSR 28.79 B

1

1115

1115.14

... More
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. (CSR 28.77)

1

2816

2816.25

... More
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.(CSR 28.78)

1

608

608.53

... More
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. 200mm internal diameter (CSR 28.80 (c))

1

777

777.73

... More
Foot Rest for Manhole. Providing orange colour safety footrest CSR 29.35

5

220

1100.9

... More
Earth work in excavation in foundation and trenches as per CSR 6.6

185.79

191

35623.37

... More
Cement Concrete 1:2:4 with stone ballast or shingle.using concrete mixing volumetric type CSR (10.13 (a) ii)

2.35

4919

11561.65

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. (CSR 11.6)

19.81

5426

107500.55

... More
Extra for Circular work CSR 11.64

19.81

327

6490.55

... More
12.5mm thick cement plaster 1:2 (CSR 15.7)

61.06

224

13701.86

... More
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:- (CSR 28.51 e) Second Layer :----- Coarse sand screened, cleaned and washed and graded from 3mm to 6mm (from Pathankot or approved equivalent quarry).28.51 b

6.28

2145

13476.75

... More
Third Layer :----- Bajri screened, cleaned and washed and graded from 6mm to 20mm (from Pathankot or approved equivalent 28.51 c quarry).

6.28

1472

9249.18

... More
Fourth Layer :----- Bajri (Coarse) screened, cleaned and washed and graded from 20mm to 25mm (from Pathankot or approved equivalent quarry)..CSR 28.51 d

6.28

1390

8731.08

... More
Bottom Layer :----- Broken stone, screened, cleaned and washed and graded from 50mm to 75mm (from Pathankot or approved equivalent quarry).CSR 28.51 e

12.57

1374

17282.62

... More
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. CSR 10.15

3.03

5428

16448.93

... More
Centring and shuttering for flat surface such as Suspended floors, Roofs, Landing, Chhajjas, Shelves etc. (CSR 9.8)

16.79

560

9410.12

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete(CSR 18.18)

2.42

7920

19167.8

... More
RCC Man hole Cover CSR 29.36 (a ) size 560 mm i/d heavy duty

2

1169

2338.78

... More
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.(CSR 18.4)

1.83

10848

19798.07

... More
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Phillaur Sand (Av. Lead 167 Km) 0 to 167 km

20.17

654

13205.3

... More
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Ghaghar Sand (Av. Lead 320 Km) 0 to 320 km

3.55

913

3243.88

... More
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Bajri (Av. Lead 320 Km) 0 to 320 km

20.28

913

18531.26

... More
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km Filter Media (Av. Lead 320 Km) 0 to 320 km

31.42

913

28710.65



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.