Public Works Department Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 11,27,000Document Cost
₹ 30,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDBR_135378_1Bid Award Id
ViewTender No
Bid No 05 Dt.25-06-2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwdpunjab.gov.in/index
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification clause 302.
2875.03
-
-
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
2875.03
-
-
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 mtr. Transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with lead upto 10.00 kms as per Technical Specification clause 301.5
7488.09
-
-
Loosing, Levelling and Compacting origional Ground supporting embankment to facilitate placement of first layer of embankment , scarified to a depth of 150 mm,complete as per Technical specification clause 301.4.1
3433.92
-
-
Providing and laying brick on end edging after removal of existing brick edging complete as per Technical specification clause 412.
12780.92
-
-
Granular Sub Base (GSB)
-
-
-
Construction of granular sub base by providing well graded material, spreading in uniform layers on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical specification clause 401
3183.52
-
-
Construction of granular sub base by providing well graded material, spreading in uniform layers on prepared surface, mixing by mix in place method at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical specification clause 401 (Relaying of material to be recieved from Scarification)
478.72
-
-
Water Bound Macadam Sub-base/base(WBM Grading -II)
-
-
-
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening type-A/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.
4631.01
-
-
Water Bound Macadam Sub-base/base(WBM Grading -III)
-
-
-
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening type-B to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
2804.14
-
-
Primer Coat over Granular Base(with emulsionSS-1 Bulk)
-
-
-
Providing and applying primer coat with bitumen emulsion (SS-1) Bulk on prepared surface of granular base including cleaning of road surface and spraying primer at the rate 0.85 kg/sqm using mechanical means as per Technical specification clause 502
37388.53
-
-
Tack Coat (with VG-10 bitumen @ 0.275 kg/ sqm)
-
-
-
Providing and applying tack coat with Bitumen VG-10 using tar boiler / pressure distributor at the rate of 0.275 kg. per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical specification clause 503
37441
-
-
Bituminous Macadam ( with VG-10 bitumen)
-
-
-
Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder VG-10, transported to site and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.
1869.43
-
-
Providing, laying and rolling of close-graded premix surfacing material (mixed seal surfacing) of 25 MM thickness composed of 13.2 mm to 0.09 mm (Type-B) aggregates @0.338 cum/10 Sqm. using penetration grade bitumen (VG-30) @23.75 Kg. per 10 Sqm. to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 (MSS), including all leads, lifts and carriage of materials complete as per satisfaction of Engineer-in-charge.
37441
-
-
C.D. Work
-
-
-
Earth work in excavation of foundation of structures as per drawing and technical specification 305.1, including setting out, construction of shoring and bracking, removal of stumps and other deleterious material & disposal up to 50 mtrs, dressing of sides and bottom and backfilling in trenches with approved material.
1597.52
-
-
Providing Plain cement concrete 1:3:6 nominal mix in foundations complete as per drawing & technical specifications clauses 802, 803, 1202,
1203.
182.94
-
-
Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii) complete as per drawing & technical specifications clauses 800 & 1100
40.44
-
-
Brick Masonry work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering as per Drawing and Technical
Specifications 600, 1202, & 1203
235.26
-
-
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding
excavation, protection works, backfilling,
150
-
-
Plastering 15mm with cement mortar (1:4) on brick work in substructure as per Technical
specification 613.4, &1204.
2812.51
-
-
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification
Clause 1701
660.83
-
-
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause
1701
29000
-
-
Providing concrete for plain concrete (PCC M-
20) in open foundations complete as per
drawings and technical specifications Clause 802, 803, 1202 & 1203
26.73
-
-
Brick masonry work in cement mortar 1:3 in parapet excluding pointing and plastering as per drawing and technical specifications Clauses
600, 900 and 1208.4
16.21
-
-
Providing and laying reinforced cement concrete (RCC M-25) in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
16.37
-
-
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
1.47
-
-
Ist class Brick Work 1:4 in foundation complete as per MORD specifications 600&1200
376.95
-
-
Ist class Brick Work 1:4 in Substructure complete as per MORD specifications
600&1200
52.25
-
-
Provision for road signage boards asl per NRIDA Guidelines (First Revision-2019) and IRC:67 & other road furniture
Retro-reflectorised Traffic Signs 900x900x900mm triangular
-
-
-
Providing and fixing of retro-reflectorised (Class A/Class B) cautionary, mandatory and informatory sign as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over ACP Sheet 3.00 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
94
-
-
Retro-reflectorised Traffic Signs 600x600x600mm triangular/octagonal/ circular Boards
-
-
-
Providing and fixing of retro-reflectorised (Class A/Class B) cautionary, mandatory and informatory sign as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over ACP Sheet 3.00 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
39
-
-
Direction and Place Identification signs with size 900x600mm
-
-
-
Providing and erecting direction and place identification retro-reflectorised (Class A/Class B) Sign as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over over ACP Sheet 3.00 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
6
-
-
Direction and Place Identification signs with size 600x450mm
-
-
-
Providing and erecting direction and place identification retro-reflectorised (Class A/Class B) Sign as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over over ACP Sheet 3.00 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
1
-
-
Direction and Place Identification signs with size 1200x900mm
-
-
-
Providing and erecting direction and place identification retro-reflectorised (Class A/Class B) sign as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over over ACP Sheet 4 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
3
-
-
Providing and fixing of typical PMGSY informatory sign board with Logo
-
-
-
Providing and fixing of typical PMGSY informatory sign board with Logo as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 and drawing. The ACP Plates of 3 mm thick, top and middle plate duly ribbted with MS flat iron 25mm x 5m size on back on edges. The lower ACP plate 4 mm will be ribbted with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be ribbted to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro-reflectorised Tape (Class A/Class B) in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
2
-
-
Providing and fixing of Standard PMGSY Logo Sign Board Double Sided
-
-
-
Providing and fixing of typical PMGSY Logo as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 and drawing. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro-reflectorised Tape(Class A/Class B) in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
3
-
-
Providing and Fixing Citizen Informatory Board of PMGSY Project/ Maintenance Board
-
-
-
Providing and fixing of typical PMGSY Citizen informatory sign board as per NRIDA Guidelines (First Revision-2019) and IRC:67-2012 and drawing. Two ACP Plates of 4 mm thick duly ribbted with MS angle iron frame of 25mm x 25mm x 3mm. The angle iron frame will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 600mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. with Retro-reflectorised Tape (Class A/Class B) in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
4
-
-
Hazard Marker sign board 300x900mm rectangular as per IRC 67-2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2mm thick aluminium sheet with 25x25x3mm angle iron frame supported on a mild steel angle iron post 65x65x6mm firmly fixed to ground including foundation concrete 1:2:4 of size 0.45x0.45x0.60m for vertical post complete as per technical clause 801 of MORT&H specifications
58
-
-
Chevron Sign Board 500x600mm (Double board at a site)
-
-
-
Providing and erecting direction and place identification retro-reflectorised (Class A/Class B) Sign as per (First Revision-2019) and IRC:67-2012 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over over ACP Sheet 3.00 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 750 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
48
-
-
5th Kilometre Stones
-
-
-
Providing and fixing 5th Km. stones of standard design including painting and printing, etc as per drawing and Technical Specification Clause 1703.
1
-
-
Kilometre Stones
-
-
-
Providing and fixing Km. stones of standard design including painting and printing, etc as per drawing and Technical Specification Clause 1703.
5
-
-
200m Stones
-
-
-
Providing and fixing 200m stones of standard design including painting and printing, etc as per drawing and Technical Specification Clause 1703.
27
-
-
Boundary Pillar
-
-
-
Providing and fixing of boundary pillars of standard design as per drawing and Technical Specification Clause 1704
65
-
-
Road stud 100 x 100 mm
-
-
-
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.
1977
-
-
Delinators (Roadway Indicators)
-
-
-
Providing and fixing of Delinators (Roadway Indicators) not less than 800mm high above ground level. The delinator shall have a core & shell construction which shallbe madeof tough, high impact resistant, injection - moulded, thermoplastic outer body. The inner core shall consist of powder coated or painted mild steel of minimum thickness1.00mm, The delinatorshould have top retro-reflective unit consisting of white colour micro prismatic non matallic retro reflective sheeting on both sides having minimum exposed area of 125 sq.cm each side and bottom retro reflectiveunit consisting of red colour micro prismatic non matallic retro reflective sheeting on both sides having minimum exposed area of 35 sq.cm each side confirming to ASTM D4956 type XI standards. The delinators shall be fixed to the groundby insertingthe root of the delinators upto the marked portionand by firm concrete filling as per the instructions by the Engineer-in-charge
64
-
-
Rumble strips
-
-
-
Providing and making rumble strips 15-20mm high at centre, 250mm wide placed at 1m centre to centre over freshly laid bituminous layer by using close graded premix surfacing material type B at approved locations to control speed and marked with 100mm wide white strips of thermoplastic road marking paint. The close graded premix surfacing material type B shall conform to technical clause 512 and thermoplastic road marking paint shall conform to technical clause 803 of MORT&H specifications
888
-
-
Road Marking
-
-
-
Markings of centre line, Zebra lines with hot applied thermoplastic road marking paint material conforming to MORT&H clause 803.4.2 and marking complete as per clause 803 of MORT&H specifications 2004 (upto date revision)
1551.2
-
-
AMC for 1st Year (Fixed Rate = 60729.00, bidder(s)/vendor(s) need not to quote for this)
6.4
-
-
AMC for 2ndYear (Fixed Rate = 73493.00, bidder(s)/vendor(s) need not to quote for this)
6.4
-
-
AMC for 3rd Year (Fixed Rate = 107553.00, bidder(s)/vendor(s) need not to quote for this)
6.4
-
-
AMC for 4th Year (Fixed Rate = 99020.00, bidder(s)/vendor(s) need not to quote for this)
6.4
-
-
AMC for 5th Year (Fixed Rate = 147280.00, bidder(s)/vendor(s) need not to quote for this)
6.4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements