Public Works Department Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 4,58,210Document Cost
₹ 20,000Tender Fee
₹ 5,900
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CEPW_133618_1Tender No
Tender Notice no. 26 Dated 24/01/2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwdpunjab.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Earthing with 40mm x 5mm Copper Tape (upto 14Metre in Length)
10
34269
342693
... More
COPPER EARTHING (Upto 23 metre in Length):
Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 19.50 metre (63.96 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 23metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 18metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 40mm x 5mm Copper Tape (upto 23 Metre in Length)
6
51617
309702.48
... More
COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
Additional Length 25mm x 5mm thick Copper Tape
50
1039
51990
... More
Additional Length 40mm x 5mm thick Copper Tape
100
1631
163124
... More
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
10
325
3259.5
... More
CABLE TRAY:
Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
Cable Tray Size 150mm x 50mm x 50mm (2mm thick)
25
1066
26658.75
... More
Cable Tray Size 300mm x 50mm x 50mm (2mm thick)
50
1455
72786.5
... More
S/E of LT Cast Resin type/ Heat Shrinkable Termination Kit for Outdoor/ Indoor supply of 1.1 KV grade PVC/XLPE cable as desired by the Engineer in charge of the site:-
Heat Shrinkable Outdoor/ Indoor End Termination Kit for Cable Size 3½/4 Core 70-150sq.mm
4
1784
7138.08
... More
Heat Shrinkable Outdoor/ Indoor End Termination Kit for Cable Size 3½/4 Core 225-300sq.mm
4
2556
10227.8
... More
XLPE INSULATED HT CABLES:
XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND):
Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:-
HT Cable Overall size 95sq.mm (3Core) ( Fom VCB Main to Transformer 1000kva 3 no's)
120
1270
152462.4
... More
HT Cable Overall size 300sq.mm (3Core) ( Fom Meter Room to VCB Main in HT Room x 2 Parallel run)
400
2295
918316
... More
S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:-
Heat Shrinkable End Termination for cable size 240-400 sq. mm, 3Core (Indoor Type)
4
4635
18542.44
... More
Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Indoor Type)
6
3131
18787.26
... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 180/ 152mm (Outer/ Inner dia.)
80
426
34133.6
... More
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
Depth not exceeding 3 m. BG
All kinds of soil except rocky
180
104
18774
... More
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C.
inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
6
6780
40681.98
... More
600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal
8
8970
71764.4
... More
Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type Extenable 4 no's VCB (Vacuum Circuit Breaker) switch board unit 800/630 Amp.totally factory assembled which includes 800/630 Amp. Vacuum Circuit Breaker for 1 no. Incoming and 3 no. Out goings VCB 800/630Amp. 'Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of Min. 21kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 50 opeartion
-
-
-
... More
VCB parameters are as below: (a). Rated Voltage: 11kV
(b). Rated short circuit breaking current withstand : Min. 25kA for 3sec.
(c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak
(d). Rated insulation voltage( Power frequency withstand) : Min. 28kV
(e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO
(f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz)
(g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) VCB incorporating mechanical as well as electrical ON/OFF indiaction "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door.
Incomer shall consist of:
(a). Cast Resin CT's 11kV : 250-200/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA
(b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA
-
-
-
... More
(c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type
(d). Master Trip/ Anti pumping relay
(e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.
(f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.
(g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard
(h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations
(i) Power Pack with battery & battery charger suitable for realys of VCB for functioing of relays.
All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments.
-
-
-
... More
Outgoing shall consist of:
(a). Cast Resin CT's 11kV : 100-60/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection
(c). Master Trip/ Anti pumping relay
(d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal
(f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard
(g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations
All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:-
-
-
-
... More
11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type 4no's VCB (Vacuum Circuit Breaker) Switch board unit 800/630 Amp. which includes 1 No. 800/630 Amp. Vacuum Circuit Breaker for Incomer and 3 no. Out going feeder
complete in all respects as approved and desired by the Engineer-in-charge at site.
1
2465305
2465305
... More
Supply, installation, testing and commissioning of 11KV/433V Indoor/ Outdoor type floor mounted Distribution Transformer 1000KVA, totally factory assembled Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor cnforming to IS:1180 (2021) Level-2 (As Amendment -4) & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV
(c) On Load Tap changer + RTCC + AVR: +5% to -15% off circuit tapping in steps of 1.25%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C
(f). Oil/ Winding temperature rise: As per IS:1180
(g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side
(j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp
-
-
-
... More
The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer testing lab to be NABL certified & manufacturer shall ensure that there is no mixing of second grade core for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:- The Supervision,Inspection & testing at Manufactuers site(By department)
-
-
-
... More
1000 KVA Three Phase Distribution Transformer 11KV/433V, 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor having percentage impedence and Losses at 50% & 100% Loading conforming to IS:1180 (2021) Level-2 (As Amendment -4) DistributionTransformer complete in all respect as approved and desired by the Engineer in-charges at site
3
4200398
12601194
... More
Designing, Supplying, installation, testing &commissioning of Indoor cubical type Main LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 60439-1&2 -Partallyt Totally Type Tested panel with IP 42 (indoor type).LT Panel shall be tested for all type test as per IEC 60439-1&2 & IEC61641 with aluminum busbar,The manufacturer shall submit the all type test reports during drawing approval. (Dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system,IP54/55 and minimum 50kA. The Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 60439-1&2 . The Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C. The Supervision,Inspection & testing at Manufactuers site(By department)
Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet,,conforming to IS:8623. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The door should be double door design without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement.
-
-
-
... More
The Panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel.The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.
Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7 tank Powder coated process should present in company pemises) after necessary putty work . Busbar :- The panel shall be provided with TPN aluminium busbar of suitable size according to the size of ACB/MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium. All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports.The main busbar would be supported upon non-hygroscopic supports and Breaker should be compatible for communication on Modbus TCP/IP for future scope. ACB terminals should be rotatable type.
-
-
-
... More
Metering :- The panel shall complete with also have digital metering unit with selector switch (volt meter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. The switchboard Main distribution panel shall restrict the internal arcs faults within the compartment to ensure maximum safety to the operating personnel.
The ACB should be capable for recording 10 fault history, LCD Display of current & voltage, Icu = Ics = Icw (1 Sec.) = 50kA with no derating upto 50 degree celcius on the existing industrial panel (With terminal adapter on load and line side of breaker),
Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO9001:2015 standerd) and NABL Lab reports of calibiration. The Concerened contactor shall be provide the detailed drawing of panel with attested and submitted to department for approval with complete specification and approved from the Engineer in charge at site.
Bus Bar :- 2000A, TPN Aluminium Busbar suitable for with standing fault level of 50KA with heat shrinkable coloured sleeves i/c SMC/DMC bus bar supports at required intervals. (Current density shall be maximum 1.3 A/sqmm) Detail of ACB/MCCB's to be installed in the cubical panel Enclosure as per following .
-
-
-
... More
Main LT TTA Panel ( SubStation -1 ) for Transformer T1,T2 & T3 ( 3 X 1000KVA)
Bus Bar :- 2000A, TPN Aluminium Busbar suitable for with standing fault level of 50KA with heat shrinkable coloured sleeves i/c bus bar supports at required intervals. (Current density shall be maximum 1.3 A/sqmm) Main Incomer:- 1. ACB 1600 Amps. EDO type FP, Icu = Ics = Icw (1 Sec.) = 50kA, microprocessor based trip sytem with thermal memory, zone selective interlocking, pre trip alarm, individual fault indicating LED, release with LSIG protection = 1No. and Multi Function Meter with display parameter of Voltage, Ampere, KW, KWH, KVA, Frequency, PF, % THD, phase angle and LED Cluster Indicating lamps and 2 Amp control MCB suitable size CTs = 1No. Outgoings:- . 1. MCCB 630Amp. Microprocesser based , Four Pole, 36KA Microprcoessor based release with (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle=4 no. (For 3no. Charger Panel + 1no. Spare) and Multi Function Meter with display parameter of Voltage, Ampere, KW, KWH, KVA, Frequency, PF, phase angle and LED Cluster Indicating lamps and 2 Amp control MCB suitable size CTs =4 no.,
3
853291
2559873
... More
Supply, Installing testing and commissioning of 2000A, 3P + 100% Neutral, 50KA For 1 Sec,Sandwich Type Bus trucking Straight Feeder Length,Aluminium Conductor, IP 65 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc. complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
60
28804
1728240
... More
Supply, installation, testing and commissioning Elbow vertical / Horizontal / off set Bend 2000Amp / 3P+1N+E complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
12
10602
127224
... More
Supply, installation, testing and commissioning Flange End Unit 2000Amp complete with hardware-nuts and bolts complete in all respects as approved and desired by the Engineer-in-charge at site.
6
15891
95346
... More
Supply, installation, testing and commissioning Copper Flexible 2000Amp complete with hardware-nuts and bolts complete in all respects as approved and desired by the Engineer-in-charge at site.
6
43395
260370
... More
Supply, installation, testing and commissioning of Adopter Box/tap off box for Transformer side and panel side 2000Amp. complete in all respects as approved and desired by the Engineer-in-charge at site.
6
13834
83004
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%