Patiala Locomotive Works Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Patiala Locomotive Works - PLW Tender

Works
Electrical and Electronics
Electrical Works
Ireps
Opening Date6 Aug 2024
Closing Date29 Aug 2024
Tender Amount₹ 12,61,142.64 
Notes
Download

Costs

Summary

Electrical Work Required For "extension Of Existing Sports Building In Stadium Area By 60'x50'for

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, wiring/rewiring, testing & commissioning of power plug points 16/6 amp. 06 pins modular type socket, 16 Amp. modular type switches with FRLS/FRLSH, multi strand Copper conductor wire PVC 4 insulated, 1100 volts grade, ISI marked size 4.0 sq. mm. from MDB/PDB to proposed points separately for phase and neutral along with 14 SWG bare Copper wire for Earth continuity with all accessories such as modular type GI box of suitable size, modular base and cover plate, 16 Amp modular type switch, socket, steel/brass screws, cup washer etc as required at site. complete in all respect as per technical specifications and site requirements.

20

962

19254

... More
Supply, wiring/rewiring, testing and commissioning of single phase AC plug points with 4.0 sq.mm. 5 multi strand Copper conductor, FRLS/FRLSH, PVC insulated 1100 V grade, ISI marked, single core wire from MDB/PDB to proposed point along with 14 SWG bare Copper wire for Earth continuity with all accessories such as 32 Amp. double pole "C" curve MCB, MS MCB box with cover duly flushed in wall, Steel/Brass screw, cup washer etc. as per technical specification & site requirements.

61

1281

78182.48

... More
Supply, wiring/rewiring, testing and commissioning of single phase Air curtain point wiring with 4.0 6 sq.mm. multi strand Copper conductor, FRLS/FRLSH, PVC insulated 1100 V grade, ISI marked, single core wire from MDB/PDB to proposed point along with 14 SWG bare Copper wire for Earth continuity with all accessories such as 32 Amp. double pole "C" curve MCB, MS MCB box with cover duly flushed in wall, Steel/Brass screw, cup washer etc. as per technical specification & site requirements.

4

1281

5126.72

... More
Excavation of Kachcha trench/Pucca trench/any other terrain (750 mm deep from ground level & 7 width 350 mm), laying, termination, testing and commissioning PVC/XLPE, armoured, Aluminium conductor LT cable of size 4CX300 sq. mm. in Kachcha trench/Pucca trench/any other terrain/through HDPE pipe/G.I. pipe/RCC pipe as per technical specification and site requirements.

1000

136

136400

... More
Excavation of Kachcha trench/Pucca trench/any other terrain (750 mm deep from ground level & 8 width 350 mm), laying, termination, testing and commissioning PVC/XLPE, armoured, Aluminium conductor LT cable of size 4CX50 sq. mm. in Kachcha trench/Pucca trench/any other terrain/through HDPE pipe/G.I. pipe/RCC pipe as per technical specification and site requirements.

350

84

29582

... More
Excavation of Kachcha trench/Pucca trench/any other terrain (750 mm deep from ground level & 9 width 350 mm), laying, termination, testing and commissioning PVC/XLPE, armoured, Aluminium conductor LT cable of size 4CX70 sq. mm. in Kachcha trench/Pucca trench/any other terrain/through HDPE pipe/G.I. pipe/RCC pipe as per technical specification and site requirements.

200

84

16904

... More
Design, Supply, transportation, Installation, testing and commissioning of Feeder Pillar Box, TP&N, 415 volts, 50 Hz AC including construction of RCC foundation and Electrical accessories as per technical specifications and site requirements.

1

153267

153267.5

... More
Supply, erection, testing & commissioning of G.I. Plate Earthing stations as per PLW drawing no. PLW/EL/PD/1512/Rev-I), site requirements and technical specifications complete with the followings:- i) GI Earthing plate size 600x600x6 mm as an Earthing electrode ii) GI strip size 38x3/25x5 mm (minimum cross 11 section 114 sq. mm.) to Earth pit iii) 'B' class GI pipe 6 mtr. long of 38 mm. dia iv) 220 Kg. Salt and 120 Kg charcoal filling v) GI pipe, funnel, CI cover etc. vi) Excavation of approximately 900 mm diameter, 7 meter deep pit in ground, assembling and lowering of Earthing GI plate, GI Pipe, GI Earthing strip and filling of pit with charcoal, salt & Earth, pouring of water into pit, making of C.C.masonary Earth pit with cover and writing Earthing value on nearest wall with paint.

2

8162

16325.48

... More
Supply, erection, testing and commissioning of GI Pipe Earthing complete with all accessories i.e. 12 G.I. B class pipe, GI Earth wire 8 SWG for earth continuity from earth pit to first street light pole (both side), salt, charcoal, CC pit & RCC cover etc. as per drawing no. DMW/EL/PD/1428, technical specification and site requirements.

5

2251

11256.75

... More
Supply, laying and connection of G. I. Earthing strip of size: 38X3/25X5 mm. (minimum cross section 114 sq. mm.) from Earthing station to proposed MDB/SDB/feeder pillars/DG sets/Panels etc. and as per technical specifications and site requirements.

10

105

1051.2

... More
Supply and laying of GI Earth wire 8 SWG as per technical specifications and site requirements.

220

30

6754

... More
Installation, testing and commissioning of Energy efficient Ceiling fans 1200 mm sweep as per technical specifications and site requirements.

2

74

149

... More
Installation, testing and commissioning of fresh air fan 300 mm. sweep complete in all respect with all accessories and hardwares required at site as per technical specifications and site requirements.

20

74

1490

... More
Supply, laying & fixing of ISI marked PVC conduit pipe 25 mm dia to be concealed in wall/on wall 17 surface where as required along with all accessories such as PVC pipe bends, junction boxes, junction box covers, steel saddle clamps, steel screws etc. complete in all respect as per technical specifications and site requirements.

2000

48

96340

... More
Supply & laying of GI pipe 3" dia as per technical specifications and site requirements.

20

807

16150

... More
Supply, installation, testing and commissioning of TP&N, double door Power Distribution Board 19 comprising of the followings as per technical specifications and site requirements: (i) 4 pole MCCB 100 A as incomer -01 No. (ii) DP MCB 63 A 'C' series- 03 No. (iii) SP MCB 6-32 A 'C' series- 18 No. (iv) Neutral link - 01 No. (v) Danger Plate - 01 No. (vi) Busbar arrangement - 01 set

6

12347

74085.6

... More
Supply, installation, testing & commissioning of TP&N, double door Light Distribution Board 20 comprising of the followings and as per technical specifications and site requirements:- (i) TPN MCB 63A "C'' series as a incomer- 01 No. (ii) DP MCB 40A "C'' series - 03 Nos (iii) SP MCB 6-32 Amp 'C' series - 18 Nos (iv) Danger Plate - 01 No. (v) Neutral Link - 01 No. (vi) Busbar Arrangement - 01 Set.

3

11542

34628.16

... More
Supply, Installation, testing & commissioning of single phase Air curtain unit of size 3 feet complete in all respect as per technical specification and site requirements.

4

21596

86385.44

... More
Installation, testing and commissioning of Recess mounted LED Light Panel 2 feetX2 feet (±1%), suitable for recess mounting 34-38 watt, 230 volts single phase AC supply with connections above false ceiling with all necessary hardware/material required at site as per technical specification and site requirements.

70

285

19950

... More
Installation, testing & commissioning of energy efficient LED based street light luminaire 30-35 watt 23 to be used as security light with suitable size pipe bracket complete in all respect with all accessories and hardwares as per technical specifications and site requirements.

18

285

5130

... More
Installation, testing and commissioning of energy efficient LED based tube light fittings 20-22 watt complete with LED tube rod be installed at site with all accessories and hardwares required & as per technical specifications and site requirements.

12

56

682.8

... More
Supply and erection of modular type GI concealed switch box of size 8"X6" suitable for installation of modular switchs/modular plate as per technical specifications and site requirements.

20

196

3936.8

... More
Installation, testing and commissioning of Bracket fans 400 mm sweep (wall mounted) suitable to operate on 230 volts ± 5%, 50 Hz., single phase Ac supply complete in all respect ready to install at site with all accessories and material/hardware required as per technical specifications and site requirements.

50

74

3725

... More
Supply, installation, testing and commissioning of LED light fittings suitable for boxing ring application complete in all respect with all mounting arrangements and all accessories and hardwares required for this as per technical specifications and site requirements.

50

5645

282268

... More
Excavation of pucca trench/trenchless tunnel in pucca floor/dabar road (750 mm deep from ground 28 level & width 350 mm), supply and laying of DWC HDPE pipe of size 160 mm/130 mm dia including laying of cable of size 4CX300 sq. mm through pucca trench/trenchless tunnel as per technical specifications and site requirements.

35

799

27966.05



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.