Patiala Locomotive Works Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 4,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Electrical Work Required For "construction Of New Sports Hostel Near Existing Sports Hostel In Colony-2, Plw/pta".
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
PLW-EL-411-24-PLW HQ-ELECTRICAL/PLWTender No
PLW-EL-411-24Tender Authority
Patiala Locomotive Works ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply, wiring/rewiring, testing & commissioning of light plug points minimum 6 amp. 3 pins modular type socket, minimum 6 Amp. modular type switch with FRLS/FRLSH, multi strand copper conductor 4 wire PVC insulated 1100 Volt grade ISI marked, size 1.5 sq. mm for phase & neutral separately along with 14 SWG bare Copper conductor wire for earth continuity from MDB/LDB/PDB to the proposed point with all accessories such as modular type GI box of suitable, modular base and cover plate of suitable size, minimum 6 Amp. modular type switch, minimum 6 Amp 3 pin modular type socket, washer, brass/steel screws etc. complete in all respect as per technical specifications and site requirements.
11
635
6985
Supply, wiring/rewiring, testing & commissioning of power plug points 16/6 amp. 06 pins modular type socket, 16 Amp. modular type switches with FRLS/FRLSH, multi strand Copper conductor wire PVC 5 insulated, 1100 volts grade, ISI marked size 4.0 sq. mm. from MDB/PDB to proposed points separately for phase and neutral along with 14 SWG bare Copper wire for Earth continuity with all accessories such as modular type GI box of suitable size, modular base and cover plate of suitable size, 16 Amp modular type switch, socket, steel/brass screws, washer etc as required at site. complete in all respect as per technical specifications and site requirements.
8
962
7701.6
Supply, wiring/rewiring, testing & commissioning of Geyser Plug Point Wiring with 4.0 sq.mm. multi 6 strand Copper conductor, FRLS/FRLSH, PVC insulated 1100 V grade, ISI marked, single core wire from MDB/PDB to proposed point along with 14 SWG bare Copper wire for Earth continuity with all accessories such as 32 Amp. double pole "C" curve MCB, MS MCB box with cover duly flushed in wall, Steel/Brass screw, cup washer etc. as per technical specification & site requirements.
2
1281
2563.36
Supply, wiring/rewiring, testing and commissioning of single phase AC plug points with 4.0 sq.mm. 7 multi strand Copper conductor, FRLS/FRLSH, PVC insulated 1100 V grade, ISI marked, single core wire from MDB/PDB to proposed point along with 14 SWG bare Copper wire for Earth continuity with all accessories such as 32 Amp. double pole "C" curve MCB, MS MCB box with cover duly flushed in wall, Steel/Brass screw, cup washer etc. as per technical specification & site requirements.
5
1281
6408.4
Installation, testing and commissioning of Energy efficient Ceiling fans 1200 mm sweep as per technical specifications and site requirements.
20
74
1490
Supply, Installation, connection, testing and commissioning of Stepped type modular electronic ceiling fan regulator as per technical specifications and site requirements.
20
196
3936.8
Installation, testing and commissioning of Bracket fans 400 mm sweep (wall mounted) suitable to operate on 230 volts ± 5%, 50 Hz., single phase Ac supply complete in all respect ready to install at site with all accessories and material/hardware required as per technical specifications and site requirements.
5
74
372.5
Installation, testing and commissioning of Exhaust fan 380 mm. sweep complete in all respect with all accessories and hardwares required at site as per technical specifications and site requirements.
1
373
373.4
Installation, testing and commissioning of fresh air fan 300 mm. sweep complete in all respect with all accessories and hardwares required at site as per technical specifications and site requirements.
2
74
149
Installation, testing and commissioning of energy efficient LED based tube light fittings 20-22 watt complete with all accessories and hardwares required & as per technical specifications and site requirements.
45
56
2560.5
Laying of PVC/XLPE, armoured, Aluminium conductor LT cable of size 4CX70 sq. mm in the existing excavated trench/through Hume pipe/GI pipe/HDPE pipe as per technical specifications and site requirements.
350
14
5166
Excavated of trench under soft soil minimum 750 mm deep & 350 mm wide for laying of XLPE aluminimum armoured cables of all sizes as per site requirement and provide sand cushioning of 75 mm thick layer around the cable and top protection with class B bricks, laterally to cable length of cable as per PLW drawing (the sand, bricksetc are in the scope of the tenderer). The trench to refilled back after laying of cable to 15 bring the surface to original level as per technical specification and site requirement.
334
128
42752
Digging of pucca/concrete soil with the help of bockie for crossing the roads/pathways/pucca surface area etc. The hole of bockie shall be 750 mm below the top surface of the road as per technical specifications and site requirements.
16
295
4724.16
Supply, erection, testing & commissioning of G.I. Earthing station as per PLW's Drawing No. DMW/EL/PD/1512, site requirements and technical specification complete with the followings:- i) GI Earthing plate size 600x600x6 mm as an Earthing electrode ii) GI strip size 38x3/25x5 mm (minimum cross section 114 17 sq. mm.) to Earth pit iii) 'B' class GI pipe 6 mtr. long of 38 mm. dia iv) 220 Kg. Salt and 120 Kg charcoal filling v) GI pipe, funnel, CI cover etc. vi) Excavation of approximately 900 mm diameter, 7 meter deep pit in ground, assembling and lowering of Earthing GI plate, GI Pipe, GI Earthing strip and filling of pit with charcoal, salt & Earth, pouring of water into pit, making of C.C.masonary Earth pit with cover and writing Earthing value on nearest wall with paint.
2
8162
16325.48
Supply, laying and connection of G. I. Earthing strip of size: 38X3/25X5 mm. (minimum cross section 114 sq. mm.) from Earthing station to proposed MDB/SDB/feeder pillars/DG sets/Panels etc. and as per technical specifications and site requirements.
25
105
2628
Supply, laying & fixing of ISI marked PVC conduit pipe 25 mm dia to be concealed in wall/on wall 19 surface where as required along with all accessories such as PVC pipe bends, junction boxes, junction box covers, steel saddle clamps, steel screws etc. complete in all respect as per technical specifications and site requirements.
300
48
14451
Supply & laying of GI pipe 3" dia as per technical specifications and site requirements.
10
743
7430.2
Supply, installation, testing and commissioning of TP&N, double door Power Distribution Board 21 comprising of the followings as per technical specifications and site requirements:(i) 4 pole MCCB 100 A as incomer -01 No.(ii) DP MCB 63 A 'C' series- 03 No.(iii) SP MCB 6-32 A 'C' series- 18 No.(iv) Neutral link - 01 No. (v) Danger Plate - 01 No.(vi) Busbar arrangement - 01 set.
1
12347
12347.6
Supply, installation, testing & commissioning of TP&N, double door Light Distribution Board 22 comprising of the followings and as per technical specifications and site requirements:- (i) TPN MCB 63A "C'' series as a incomer- 01 No. (ii) DP MCB 40A "C'' series - 03Nos (iii) SP MCB 6-32 Amp 'C' series - 18 Nos (iv) Danger Plate - 01 No. (v) Neutral Link - 01 No. (vi) Busbar Arrangement - 01 Set.
1
11542
11542.7
Supply and erection of GI Box modular type of size 5"X3" as per technical specification & site requirements.
5
78
393.65
Supply and erection of GI Box modular type of size 8"X6" as per technical specification & site requirements.
10
196
1968.4
Installation, testing & commissioning of energy efficient LED based street light luminaire 30-35 watt to be used as security light as per technical specification & site requirements.
10
285
2850
Supply and laying of HDPE pipe of 90 mm dia as per technical specification & site requirements.
16
108
1728