Panjab University Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Panjab University - PU Tender
Environmental Service
Eprocure
Opening Date8 Aug 2019
Closing Date20 Aug 2019
Tender Amount₹ 28,66,500
Costs
EMD
₹ 57,330Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_PU_51278_1Bid Award Id
ViewTender No
2098/DSWTender Authority
Panjab University ViewPurchaser Address
-Website
http://http://puchd.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Processing room:
-
-
-
... More
Processing room (brick work) 3m x 2.5m x 3m (breath, height and length respectively) (excavation, 9" rubble soling, P.C.C.:- 1:3:6, brick work:- 1:5, plastering:- 1:4) with suitable smaller platform for mixers and waste delivery system on it. Flooring of the room should be of Shahabad stone and channel for waste delivery should have glazed tiles. The room should be provided with two windows with aluminium shutters and glasss and a good solid door with all amenities. The exhaust fan is to be fitted in this room. There will be two CFL units and one wall mounted revolving fan.
-
-
-
... More
Pre-digester:
-
-
-
... More
Pre-digester should have a volume of 12 m3 (dijmensions may vary depending on the site but volume should remain constant) with a centre wall having 1.5' opening at the bottom for free slurry movement (excavation, 9" rubble soling, P.C.C.:- 1:3:6, brick work:- 1:5, plastering:- 1:4) and aeration grid in both the compartments to provide aeration at three levels of equal invtervals starting at 1' above the bottom level. The pre-digester will be covered by a slab of 4" thickness RCC with one manhole (2'x2') cast in MS (5mm) and having GI vent pipes of 10'x2' O.D. The vent pipe will be connected by a flexible pipe and emptied into predigester at the digester side. The seal for all the openings should be airtight.
-
-
-
... More
The mixer slurry will be delivered directly into pre-digester. The delivery of the slurry in the pre-digester will be through airtight opening and will not release any foul odour in the surroundings.
-
-
-
... More
Main digester:
-
-
-
... More
Main digester will have a volume of minimum 40 m3 (dimensions may vary depending on the site put volume should remain constant) and with three partition wall (excavaton, 9" rubble soling, P.C.C.:- 1:3:6, brick work:- 1:5, plastering:- 1:4) as described in our drawing. Water seal around the main digester will be as per the drawing. Thelevels will be as per the drawing. An outlet cement pipe of 9" O.D. will be provided as per the drawing and will be connected to a chamber 4'x4'x4' (excavaton, 9" rubble soling, P.C.C.:- 1:3:6, brick work:- 1:5, plastering:- 1:4). The chamber will deliver the manure slurry in manure pits through a channel.
-
-
-
... More
Manure pits:
-
-
-
... More
There will be 2 manure pits of 1.5m x 1.5m x 1.5m (excavation, 9" rubble soling, P.C.C.:- 1:3:6, brick work:- 1:5, plastering:- 1:4) as per drawing. All the pits will have a filteration system of fine sand 0.2mm (layer of 100mm), coarse sand 0.6mm (100mm) gravel 2-3mm (200mm) with drains connected through suitable pipes to an underground water tank (excavation, 9" rubble soling, P.C.C.:- 1:3:6, brick work:- 1:5, plastering:- 1:4) of 3000 L capacity and having a MS cover (5mm sheet). The manure pits are to be covered with steel mesh using proper channel supports to avoid any sagging.
-
-
-
... More
all cement structures are to be painted with cement paint and MS parts other than dome with green oil paint.
-
-
-
... More
Balloon room:
-
-
-
... More
In brick work with dimensions: 4.5M x 3M x 3M (LWH). No electrical connections in the balloon room. Two small windows (2' x 1' x 1.5') on opposite sides are to be carved in in this container which would be protected by aluminium grill and fine steel mesh to avoid rodent entry and allow good ventilation. (A good quality second hand container may be permitted after inspecting the quality). The container will have to be grouted on a cemented floor depending on site location.
-
-
-
... More
Mechanical parts:
-
-
-
... More
Mixer with a capacity of 1 MT/houer fitted with 5 HP motor (1 no.) and a SS-304 platform (5' x 2.5' x 1.5') tepering to a height of 2'.
-
-
-
... More
Compressor (2HP) (1 no.) of reputed company (of 1st make)
-
-
-
... More
Water pump 1 HP (2 no.) of reputed company (of 1st make)
-
-
-
... More
Slurry pump 2 HP (1 no.) of reputed company (of 1st make)
-
-
-
... More
A gas holder fabricated on MS (5MM sheet) with suitable reinforced structure and coated with fiber paint on outside and epoxy painting on inside will be placed in water seal before commissioning of the project.
-
-
-
... More
Electric panel with 15 ampere (3 no.) 5 ampere (6 no.) sockets ad 5 switches for tube lights, fans etc. Mixers should be provided with L&T switches to avoid tripping of power. These switches will be suitable mounted for easy and safe operations.
-
-
-
... More
Gas meter Actaris make 2.5m3/hour (2 o.) to be connected on-line
-
-
-
... More
Gas blower (twin lobe type) delivering gas at 8-10 m3/hour at 50 mbar pressure at the user end.
-
-
-
... More
Gas pipe line 50m (3" id x 15m, 2" id x 20m, x 1" id x 15m)
-
-
-
... More
Gas stove (3 no.) with 5 burners and gas consumption rate of 2m3/hour.
-
-
-
... More
Weighing scale for 1-100 kg.
-
-
-
... More
A gas balloon of minimum 40 cubic meter capacity.
1
-
2866500
... More
PART-B
-
-
-
... More
The contractor/firm should quote their Annual Maintenance Cost (AMC) for 3 years on percentage basis of the total cost. (fill the cost in showing blue)
-
-
-
... More
Time period (in year)
-
-
-
... More
1st year
1
-
-
... More
2nd year
1
-
-
... More
3rd year
1
-
-